QA204 - Testing Requirements (1).pdf
PDF 85 KB Posted
- Solicitation number
- HC101323QA204
- Issued by
-
Defense Information Systems Agency
About this file
This document outlines technical requirements for a federal contract to provide a 10Gb wavelength service between two Defense Information Systems Agency locations. The successful bidder must engineer and provision a fully diverse end-to-end circuit with separate physical paths and a minimum 50m separation. Specific requirements include single-mode fiber terminations at each location tested to an ITU standard, a 99.5% availability service with stringent performance metrics, and coordination with DISA for activation and troubleshooting. The contractor will be responsible for installation and maintenance of the fiber infrastructure and must conduct a 72-hour end-to-end test prior to acceptance.
1. IN ACCORDANCE WITH INQUIRY HC101323QA204, PROCEED TO PROVIDE, INSTALL, AND MAINTAIN A 10GB WAVE SERVICE BETWEEN (BLDG) 533; (RM) 128; (FL) 1ST; 1225 PERSHING PLACE, PATRICK SFB, FL 32925 (PTRCKSFB/CCI) AND (BLDG) 570; (RM) DI-1; (FL) 1ST; 7115 SOUTH BOUNDARY BLVD, MACDILL AFB, FL 33621-5101 (MCDLLAFB/CCI). A. THIS REQUIREMENT MUST BE ENGINEERED AND PROVISIONED TOTALLY DIVERSE END TO END TO THE GOVERNMENT'S SERVICE DELIVERY POINTS (SDP'S) FROM TSR SG26APR238267. B. THE RTD SHALL BE LESS THAN OR EQUAL TO 10 MILLISECONDS TO EFFECTIVELY SUPPORT THE GOVERNMENT'S MISSION. C. THIS 10GB WAVE TRUNK SUPPORTS BACKBONE SUSTAINMENT AND WILL REPLACE CCSD "62DA". 2. THE SERVICE DATE TO BE MET IS: 18 SEP 23 (SIP). THE GOVERNMENT WILL ASSESS CONSIDERATION IAW STANDARD PROVISION 42 FOR DELAY ON DELIVERY OF CIRCUIT ON CONTRACTED SERVICE DATE. 3. ESTABLISH TSP: TSP0MF4WU-01 4. SEE ATTACHMENTS AND UNIQUE INSTALLATION FACTORS FOR TECHNICAL REQUIREMENTS SPECIFIC TO THIS ORDER. 5. CONTRACTOR MUST UPLOAD NOTICE OF COMPLETION IN IDEAS. 6. THIS REQUIREMENT MUST BE WORKED IN CONJUNCTION WITH INQUIRY HC101323QA203 / TSR SG26APR238267 AND MUST BE ENGINEERED AND PROVISIONED TOTALLY DIVERSE END TO END FROM THE GOVERNMENT SERVICE DELIVERY POINTS (SDP) FROM TSR INQUIRY HC101323QA204 / TSR SG26APR238270; MEANING THE PHYSICAL PATHS ARE TOTALLY SEPARATE INCLUDING MANHOLES, CONDUIT, CENTRAL OFFICE LOCATIONS, AND FIBER BUILDS. ADDITIONALLY, AS A MINIMUM MUST HAVE 50 METERS PHYSICAL SEPARATION FROM TSR INQUIRY HC101323QA203 / TSR SG26APR238267.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
HC101323QA204 - TESTING REQUIREMENTS
DIVERSITY/AVOIDANCE INSTRUCTIONS:
***ATTENTION PATRICK AFB LOCATION*** THIS REQUIREMENT MUST BE ENGINEERED AND
PROVISIONED TOTALLY DIVERSE END TO END TO THE GOVERNMENT'S SERVICE
DELIVERY POINTS (SDP'S) FROM TSR SG25APR238267; MEANING THAT THE PHYSICAL
PATHS ARE TOTALLY SEPARATE INCLUDING MANHOLES, CONDUIT, CENTRAL OFFICE
LOCATIONS), AND FIBER BUILDS. ADDITIONALLY, AS A MINIMUM MUST HAVE 50 METERS
PHYSICAL SEPARATION FROM TSR SG25APR238267. ***THE 50 METER SEPARATION IS
WAIVED INSIDE BLDG 533 FOR PATRICK AFB LOCATION.***
THE TELECOM PROVIDER MUST PROVIDE DITCO COLOR POWERPOINT DRAWI NGS FOR
TECHNICAL REVIEW SHOWING THE ROUTE FROM THE COMMERCIAL DE MARCS TO THE
SUPPORTING CENTRAL OFFICES AND/OR WIRING CENTERS. D RAWINGS MUST INCLUDE
TOTAL FIBER MILES AND ROUND-TRIP DELAY (RTD). ADDITIONALLY, THE VENDOR IS TO
PROVIDE DITCO WITH DETAILED CIR CUIT/PATH CONNECTIVITY DIAGRAMS, IN KMZ OR
KML FORMAT, IDENTIFYIN G ALL POINTS OF PRESENCE (POP) FOR PROPOSAL
EVALUATION AND AS A F INAL RECORD OF THE INSTALLED PATH. THESE DIAGRAMS MUST
BE PROVID ED TO DISA HQ IE16 (DISA.MEADE.IE.MBX.IE16-PROVISIONING-TEAM@MAIL
.MIL) FOR HISTORICAL PURPOSES.
SITE SURVEYS ARE AUTHORIZED AT BOTH GOVERNMENT SITES. SINGLE MODE FIBER
MUST BE ENGINEERED/PROVISIONED IN SUCH A WAY THAT THE GOVERNMENT CAN
CHANGE/REVISE CHANNELIZATION WITHOUT TELECOM PROVIDER INTERVENTION.
A. NOTE 1 (JITTER): IN A STEADY-STATE CONDITION, THE PATTERN OF SYNCHRONOUS
TRANSPORT SIGNAL (STS) POINTER ADJUSTMENTS, SDN TO SDN (END-TO-END THROUGH
THE SERVICE PROV DED NETWORK OUTPUTS), SHALL BE NO MORE STRESSFUL (I.E.,
CREATE MORE JITTER THROUGH THE DESYNCHRONIZER AS DESCRIBED IN TABLE 6 OF
ANSI T1.105.03-1994) THAN THE POINTER ADJUSTMENT SEQUENCE IN FIGURE 5 OF ANSI
T1.105.03-1994. DURING TRANSIENT EVENTS (WHICH SHALL OCCUR NO MORE THAN 2
TIMES PER DAY), THE PATTERN OF STS POINTER ADJUSTMENTS, SDN TO SDN (END-TO-
END THROUGH THE SERVICE PROVIDED NETWORK OUTPUTS), SHALL BE FOUR OR LESS
PER HOUR. ADDITIONALLY, THE MAXIMUM TIME INTERVAL ERROR (MTIE) OVER A PERIOD
OF S SECONDS, OR WANDER, SHALL NOT EXCEED (.01S + 10000) NANOSECONDS FOR
VALUES OF S GREATER THAN 10,000.
B. WAVELENGTH TRANSMISSION SERVICES: WAVELENGTH TRANSMISSION SERVICES
FOR RATES OF 10GBPS SHALL BE O. REMARKS CONTINUED: IN ACCORDANCE WITH ITU-T
RECOMMENDATIONS G.709(03/2003), G.707(12/03), G.957(03/06), G.692(10/98) & TELCORDIA
GR253-IE4. THE PROVIDED WAVELENGTH TRANSMISSION SERVICE SHALL NOT INHIBIT
GOVERNMENT OPERATION OF UNDERLYING PROTOCOLS AND TRANSPORT SYSTEMS
SUCH AS, BUT NOT LIMITED TO, SONET/SDH, IP, ATM, GIGABIT ETHERNET, AND
ENCRYPTION. THE WAVELENGTH TRANSMISSION SERVICE PROVIDED SHALL PASS ALL
PAYLOAD, PATH AND LINE OVERHEAD BYTES TRANSPARENTLY
(UNTOUCHED/UNALTERED) AND WITHOUT MONITORING SDP TO SDP. THERE SHALL NOT
BE ANY LINE TERMINATING EQUIPMENT (LTE) BETWEEN SDP AND SDP.
C. SINGLE MODE FIBER MUST BE TERMINATED TO THE LINE SIDE OF THE FIBER
TERMINATING PATCH PANEL INSTALLED AT BOTH DISA IE1 PROVIDED SERVICE DELIVERY
NODE LOCATIONS.
D. THE TELECOM PROVIDER MUST CONTACT DISA GOC TIER-II ENGINEERING UPON
RECEIPT OF A VALID TSO TO ESTABLISH THE COORDINATION AND ACTIVATION PROCESS.
PRI POC: DISA GLOBAL CASA INFRASTRUCTURE INTEGRATION LEASE BB TEAM PHONE:
(C) 618-418-9813, (D) 418-9813 EMAIL: DISA.SCOTT.GLOBAL.MBX.CASA-INFRASTRUCTURE-
INTEGRATION-LEAS E-BB-T@MAIL.MIL ALT POC: ORGANIZATIONAL NUMBER (CASA RF
CIRCUIT ACTIVATIONS) PHONE: (C) 618-418-8691, (D) 418-8691 EMAIL:
DISA.SCOTT.GLOBAL.MBX.RF-CIRCUIT-ACTIVATIONS@MAIL.MIL
ONCE TELECOM PROVIDER HAS COMPLETED INSIDE WIRING FROM THEIR FIBER
DISTRIBUTION PANEL INSTALLED IN THEIR DWDM EQUIPMENT SUITE TO THE
GOVERNMENT SERVICE DELIVERY POINT (SDP) AT EACH LOCATION, THEY MUST ENSURE
THE LIGHT LEVEL READINGS (DB LOSS) ARE ADJUSTED TO READ +0.5 TO -7 LOSS.
ADDITIONALLY, THESE LEVELS MUST BE DOCUMENTED ON THE NOTICE OF COMPLETION
(NOC) SENT TO DITCO.
***THE VENDOR MUST TERMINATE SINGLE MODE FIBER AT BOTH LOCATIONS IAW UNIQUE
INSTALLATION FACTORS.***
THE SINGLE MODE FIBER MUST PASS A DOCUMENTED SATISFACTORY 72 HOUR END TO
END TEST IAW ITU STANDARD M.2101 PRIOR TO TURN-UP TO THE GOVERNMENT.
1. VENDOR MUST MEET SVC DATE.
2. CIRCUIT REQUIRES THE FOLLOWING PARAMETERS:
(A) FIBER TERMINATION: SINGLE-MODE INTERFACE REQUIREMENT/INTERFACE DATA
RATE: LINE CODING, FRAME FORMAT, PHYSICAL CONNECTOR, 10 GBPS, NRZ,
SCRAMBLED PER ANSI T1.104-1991 (R2003). ALL OPTIONS DEFINED SC CONNECTOR,
SINGLE-MODE FIBER PER ANSI T1.105.06-2002 (SR-0, SR-1, IR-1, IR-2, LR-1, LR-2, LR-3).
(B) LINE MUST REMAIN FULLY OPERATIONAL AND AVAILABLE TO USERS 24 HOURS A DAY,
SEVEN DAYS PER WEEK, AT LEAST 99.5% OR BETTER.
(C) ONE-HOUR RESPONSE TIME TURN-AROUND MUST OCCUR TO REPAIR ONCE TROUBLE-
CALL HAS BEEN REPORTED.
(D) GFE CLOCKING: VENDOR ESFU (OR EQUIVALENT) NOT TO BE ENGINEERED INTO
CIRCUIT.
(E) SINGLE MODE FIBER TERMINATIONS "SC" CONNECTORS.
(F) NO NETWORK INTERFACE UNIT.
(G) DEDICATED PATH.
(H) CARRIER REQUIRED TO HAVE CIRCUIT VISIBILITY TO ASSIST IN ANY CIRCUIT
OUTAGES.
(I) THE VENDOR MUST CONDUCT A 72 HOUR SATISFACTORY END TO END TEST ON THE
10GB WAVE SERVICE IAW ITU STANDARD M.2101. ADDITIONALLY, THE VENDOR TEST
SET/SETS MUST HAVE THE ABILITY TO PRINT THE TEST RESULTS AND THOSE RESULTS
MUST BE EMAILED TO THE ACCEPTING AUTHORITY FOR REVIEW.
(J) VENDOR MUST HAVE A 24X7 NETWORK OPERATIONAL CENTER.
mailto:DISA.SCOTT.GLOBAL.MBX.RF-CIRCUIT-ACTIVATIONS@MAIL.MIL
(K) THE COMMERCIAL CIRCUIT WILL BE ACCEPTED ON BEHALF OF THE GOVERNMENT BY
THE DGOC: PRI POC: DISA GLOBAL CASA INFRASTRUCTURE INTEGRATION LEASE BB
TEAM PHONE: (C) 618-418-9813, (D) 418-9813 EMAIL: DISA.SCOTT.GLOBAL.MBX.CASA-
INFRASTRUCTURE-INTEGRATION-LEAS E-BB-T@MAIL.MIL ALT POC: ORGANIZATIONAL
NUMBER (CASA RF CIRCUIT ACTIVATIONS) PHONE: (C) 618-418-8691, (D) 418-8691 EMAIL:
DISA.SCOTT.GLOBAL.MBX.RF-CIRCUIT-ACTIVATIONS@MAIL.MIL
(L) THE VENDOR MUST PROVIDE THE LONG HAUL CIRCUIT NUMBER AND THE 1-800
TROUBLE REPORT NUMBER TO THE ACCEPTING AUTHORITY PRIOR TO THE
GOVERNMENT ACCEPTING SERVICE. INSIDE WIRING MUST BE COMPLETED AND TESTED
PROPERLY IAW THE ORDER PRIOR TO TURN-UP TO THE GOVERNMENT. Q. REMARKS
CONTINUED:
VENDOR IS RESPONSIBLE FOR INSTALLATION AND MAINTENANCE OF SINGLE MODE
FIBER IAW UNIQUE INSTALLATION FACTORS.
INSIDE WIRING IS AUTHORIZED IAW WITH THE UNIQUE INSTALLATION FACTORS.
VENDOR MUST COORDINATE SITE VISIT WITH POC'S 72 HOURS IN ADVANCE PRIOR TO
REQUIRING ACCESS TO FACILITIES AT BOTH USER LOCATIONS.
FOR UNSATISFACTORY SERVICE OR TO REPORT EQUIPMENT AND/OR CIRCUIT
PROBLEMS INVOLVING DISA PROVIDED TRANSPORT AND/OR EQUIPMENT, PLEASE
CONTACT THE DISN CUSTOMER CONTACT CENTER (DCCC) SCOTT AFB, IL. TOLL FREE: 1-
855-868-9500, COML: 618-418-9500, DSN: 312-418-9500.
MINIMUM TECHNICAL SPECIFICATIONS: SPECIFIC FORMAT TO BE USED IS: LINE RATE:
10GB. LINE CODE: NRZ. FRAME FORMAT: SCRAMBLED IAW ANSI T1.104-1991 (R2003).
1. TEST AND ACCEPTANCE: FIBER OPTIC 10GB WAVE CIRCUITS SHALL PASS A FULLY
DOCUMENTED SATISFACTORY SOAK TEST BY THE GOC AT SCOTT AFB, IL. PRIMARY: (C)
618-418-8691, (D) 418-8691.
2. THE WAVELENGTH TRANSMISSION SERVICE PROVIDED SHALL MEET THE FOLLOWING
PERFORMANCE REQUIREMENTS ON A MONTHLY BASIS. PERFORMANCE
REQUIREMENT/PERFORMANCE SPECIFICATION: NON-DIVERSE/NON-PROTECTED
AVAILABILITY: GREATER THAN OR EQUAL TO 99.5% OR BETTER. MONTHLY SHORT
INTERRUPTION EVENT COUNT (SEIC): LESS THAN OR EQUAL TO 9%. ERRORED SECONDS
(ES): LESS THAN OR EQUAL TO 0.005%. SEVERELY ERRORED SECONDS (SES): LESS THAN
OR EQUAL TO 0.00035. BACKGROUND BLOCK ERROR RATIO (BBER): LESS THAN OR EQUAL
TO 5 X 10-6. BIT COUNT INTEGRITY (BCI)/PATTERN SLIP (PAT SLIP): LESS THAN OR EQUAL
TO 1 PER 72 HOURS. JITTER: SEE NOTE 1 (JITTER). R. REMARKS CONTINUED: BER: LESS
THAN OR EQUAL TO 1X10-12. DELAY (ONE WAY): * LESSER OF 10 MSEC OR (0.01 X D MSEC)
* WHERE "D" IS THE SDP TO SDP TRANSMISSION DISTANCE, MEASURED SHORTEST
GREAT CIRCLE, IN KILOMETERS. NEXT 3. ROUND TRIP DELAY (RTD) FOR THIS DISA
TRANSPORT TRUNK WILL BE MEASURED IN MILLISECONDS FROM THE CUSTOMER'S
SERVICE DELIVERY POINT (SDP) SITE-A TO THE CUSTOMER'S SERVICE DELIVERY POINT
(SDP) SITE-Z. THE RTD SHALL BE LESS THAN OR EQUAL TO 10 MILLISECONDS TO
EFFECTIVELY SUPPORT THE GOVERNMENT'S MISSION. THE GOVERNMENT ACCEPTING
AUTHORITY WILL CONFIRM THE RTD DURING THE TURN-UP AND TEST PHASE AND IF IT
mailto:DISA.SCOTT.GLOBAL.MBX.RF-CIRCUIT-ACTIVATIONS@MAIL.MIL
DOES NOT ALIGN WITH THE CONTRACTOR’S PROPOSAL, DISA IE161 WILL NOTIFY DITCO
IMMEDIATELY IN WRITING.
File details come from the government source that posted it. Updated .