QA.pdf

PDF 88 KB Posted

Attached to
C-5 Actuators, NSNs 1680-01-213-3841 and 1680-01-213-3842
Solicitation number
SPRWA1-23-R-0021
Issued by

About this file

This document contains recommended quality assurance provisions for a federal contract opportunity. The contract is for the procurement of C-5 actuators with National Stock Numbers 1680-01-213-3841 and 1680-01-213-3842 from the Defense Logistics Agency Aviation. Inspection will occur at the source per DFARS 246.402, with acceptance also at the source. The technical authority is Yohanes Tendean of AFLCMC/WLSEAB. Quality requirements include certification of conformance, contractor responsibility for inspection, and standard inspection clauses FAR 52.246-2 through 52.246-6 as applicable. A pre-award survey of new sources is recommended given the national stock numbers involved.

View the file

Other files

File Type Posted
PricingMatrix.xlsx XLSX spreadsheet
IUIDCklist.pdf PDF
SPI.pdf PDF
Pkg.pdf PDF
ID.pdf PDF
SPRWA123R0021.pdf PDF
Trans.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

RECOMMENDED QUALITY ASSURANCE PROVISIONS

AND SPECIAL INSPECTION REQUIREMENTS

1. PR / MIPR NUMBER

2. NATIONAL STOCK NUMBER

1680012133842UC

3. POINT OF INSPECTION

SOURCE DESTINATION

X

SEE DFARS 246.402

4. POINT OF ACCEPTANCE

SOURCE DESTINATION

X

5. ITEM MANAGER / PHONE

Clarington, Melanie M / 478-926-6677

6. EQUIPMENT SPEC / PHONE

Wiggins, Samuel / 478-926-6731

7. CONTRACT QUALITY REQUIREMENTS/SPECIAL INSPECTION REQUIREMENTS

CERTIFICATE OF CONFORMANCE

FAR 52.246-15

CONTRACT RESPONSIBILITY

FOR INSPECTION

FAR 52.246-1

STANDARD INSPECTION

FAR 52.246-2,-3,-4,-5 OR -6

AS APPLICABLE TO CONTRACT

X HIGHER LEVEL CONTRACT QUALITY REQUIREMENTS

NATO AQAP 2070 (or equivalent)

COMMERCIAL ITEM INSPECTION

FAR 52.212-4

OTHER (Describe in Block 8)

8. REMARKS

8a. OZONE DEPLETING SUBSTANCES (ODS)

X STATEMENT

"I HAVE REVIEWED THE REQUIREMENT, INCLUDING AVAILABLE TECHNICAL DOCUMENTATION, AND BELIEVE THAT IT DOES NOT REQUIRE THE CONTRACTOR USE CLASS I OZONE DEPLETING SUBSTANCES (ODS) IDENTIFIED IN AIR FORCE POLICY, NOR IS IT WRITTEN SO THAT IT CAN

ONLY BE MET BY THE USE OF A CLASS I ODS."

WAIVER (SEE AF FARS 5323)

NOTE: Quality provisions as annotated hereon will not be downgraded without Technical Authority coordination. The Technical Authority must be notified if award selection is made to a new source using Acquisition Method Code (AMC) 3, 4, or 5.

9. QUALITY PRE-AWARD SURVEY

YES NEW SOURCE

X PREVIOUS SOURCEX NO

AFMC PARTICIPATION

RECOMMENDED

10. CODES

A. I&A

B. CQR

G

11. SIGNATURE OF TECHNICAL AUTHORITY

Tendean, Yohanes A

ORGANIZATION / SYMBOL

AFLCMC / WLSEAB

PHONE

478-222-9488 / 472-9488

DATE

12 APR 2022

Page 1 of 1AFMC FORM 807, 20060111, V1 Version 4Generated by PRPS using Jasper Reports on 21 Oct 2022

File details come from the government source that posted it. Updated .