QA-807.pdf
PDF 87 KB Posted
- Attached to
- ROTOR, COMPRESSOR AI
- Solicitation number
- SPRTA1-25-Q-0298
- Issued by
-
Defense Logistics Agency Aviation
About this file
This AFMC Form 807 document outlines recommended quality assurance provisions and special inspection requirements for a compressor rotor acquisition. The document specifies quality control standards including FAR 52.246-15 Certificate of Conformance, standard inspection requirements (FAR 52.246-2 through -6), and higher-level quality requirements such as ISO 9001:2015, AS 9100, and NATO AQAP2070.
Key technical points include a quality pre-award survey recommended for a new source, with inspection and acceptance points designated at the source, and specific quality management contacts including Nikkia S. Fain (Item Manager, 405-734-9766) and Jeremy Barker (Equipment Spec, 405-734-8804). The document also includes an Ozone Depleting Substances (ODS) certification confirming that the contract does not require the use of Class I ODS in manufacturing, testing, or maintenance.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Transportation-1653.pdf | ||
| SPRTA125Q0298.pdf | ||
| Packaging-158.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
RECOMMENDED QUALITY ASSURANCE PROVISIONS
AND SPECIAL INSPECTION REQUIREMENTS
1. PR / MIPR NUMBER
2. NATIONAL STOCK NUMBER
2840015427488OK
3. POINT OF INSPECTION
SOURCE DESTINATION
X
SEE DFARS 246.402
4. POINT OF ACCEPTANCE
SOURCE DESTINATION
X
5. ITEM MANAGER / PHONE
Fain, Nikkia S / 405-734-9766
6. EQUIPMENT SPEC / PHONE
Barker, Jeremy / 405-734-8804
7. CONTRACT QUALITY REQUIREMENTS/SPECIAL INSPECTION REQUIREMENTS
CERTIFICATE OF CONFORMANCE
FAR 52.246-15
CONTRACT RESPONSIBILITY FOR INSPECTION
FAR 52.246-15
STANDARD INSPECTION
FAR 52.246-2,-3,-4,-5 OR -6 AS APPLICABLE TO CONTRACT
HIGHER LEVEL CONTRACT QUALITY REQUIREMENTS FAR 52.246-11
COMMERCIAL ITEM INSPECTION
FAR 52.212-4
X OTHER (Describe in Block 8)
8. REMARKS
Williams, Jacqueline NNAME: 02 JUL 2024DATE:
Contract Quality Requirements/Special Inspection Requirements:
Standard Inspection Requirements apply to CAI item and Higher Level Requirements apply to CSI Standard inspection Far 52.246-2,-3,-4,-5,-6 AS APPLICABLE TO CONTRACT
Higher Level Contract Quality Requirements FAR 52-246-11, ISO 9001:2015, AS 9100, NATO AQAP2070, (or equivalent)
ODS CERTIFICATION (Provided in lieu of Block 8a./Ozone Depleting Substances):
The subject requirement does not include any specification, standard, drawing, or other document that mandates the use of a Class I ODS in the manufacture, test, operation, or maintenance of any system, subsystem, item, component, or process; nor does it establish a test, operation, or maintenance requirement that can only be met by use of a Class I
ODS.
8a. OZONE DEPLETING SUBSTANCES (ODS)
X STATEMENT
"I HAVE REVIEWED THE REQUIREMENT, INCLUDING AVAILABLE TECHNICAL DOCUMENTATION, AND BELIEVE THAT IT DOES NOT REQUIRE THE CONTRACTOR USE CLASS I OZONE DEPLETING SUBSTANCES (ODS) IDENTIFIED IN AIR FORCE POLICY, NOR IS IT WRITTEN SO THAT IT CAN
ONLY BE MET BY THE USE OF A CLASS I ODS."
WAIVER (SEE DAFFARS 5323.8)
NOTE: Quality provisions as annotated hereon will not be downgraded without Technical Authority coordination. The Technical Authority must be notified if award selection is made to a new source using Acquisition Method Code (AMC) 3, 4, or 5.
9. QUALITY PRE-AWARD SURVEY
X YES X NEW SOURCE
PREVIOUS SOURCENO
AFMC PARTICIPATION
RECOMMENDED
10. CODES
A. I&A
B. CQR
I
11. SIGNATURE OF TECHNICAL AUTHORITY
Williams, Jacqueline N
ORGANIZATION / SYMBOL
AFLCMC / LPSDE
PHONE
405-736-7164 / 336-7164
DATE
02 JUL 2024
Page 1 of 1Prescribed by: AFMCI20-102 Version 8Generated by PRPS using Jasper Reports on 28 Feb 2025
AFMC FORM 807, 20230130 PREVIOUS EDITION IS OBSOLETE
File details come from the government source that posted it. Updated .