This document is a Requirements Document for two industrial oil/mist collectors for the 704th Test Group/846th Test Squadron at Holloman High Speed Test Track. The 846th Test Squadron requires two new oil/mist collectors for a Johnford DMC-4200 CNC Bridge Mill to maintain a safe air environment during fabrication of rocket sled parts and test track infrastructure. Specific technical requirements include a minimum air flow of 2300 CFM, static pressure of 9 in.w.g., motor power of 4.5 hp, sound level under 80 db(A), and 8" flex arms with 10' and 13' reach. The vendor must deliver the collectors within 120 days after receipt of order, provide a three-year extended warranty covering all parts and labor, and handle shipping and installation to Building 1173 at Holloman Air Force Base in New Mexico. The collectors must meet OSHA industrial air quality guidelines and include a UL standard 240V electrical control box.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MIST COLLECTOR
Requirements Document
For
704th Test Group/846th Test Squadron
28 July 2025
1.0 PURPOSE
The 846th Test Squadron (846 TS) operates the Holloman High Speed Test Track, a critical testing facility in the development of new weapon and safety systems for the Department of Defense. The 846 TS requires the purchase of two, industrial oil/mist collectors for a Johnford DMC-4200 CNC Bridge Mill to maintain a safe air environment for fabrication of rocket sled parts and components, test articles and test track infrastructure.
2.0 SCOPE
The vendor shall deliver two (2) new Oil/Coolant Mist Collectors that meet the following minimum requirements:
2.1 Physical requirements
2.1.1 Minimun air flow of 2300 CFM
2.1.2 Minimum static pressure of 9 (in.w.g.)
2.1.3 Minimum moter power of 4.5 (hp)
2.1.4 Sound level not to exceed 80(db(A))
2.1.5 Minimum suction inlets 250(mm) / 10(in)
2.1.6 8” Flex Arm with minimum 10’ reach with rigid duct trunk installation kit.
2.1.7 8” Flex Arm with minimum 13’ reach with rigid duct trunk installation kit.
2.1.8 To include necessary interface with the Johnford DMC-4200 CNC Bridge Mill
2.2 Operational requirements
2.2.1 To provide a high level of air filtration to meet or exceede OSHA guidelines for industrial air quality.
2.2.2 Electrical control box UL standard 240V.
2.2.3 One set of manuals
3.0 MILESTONES
3.1 The vendor shall deliver two (2) new Industrial Oil/Mist Collectors no later than 120 days ARO.
4.0 DELIVERABLES
4.1 The vendor shall deliver all hardware and documentation to 846 TS/TGTOHM, Attn: Charles Zamora at 1521 Test Track road, building 1173, Holloman Air Force Base, New Mexico.
4.2 Three year extended warranty (Covers all parts & labor, travel/shipping costs)
4.3 The vendor shall cover shipping and installation into 846TS facility, Bldg 1173.
| 1.0 PURPOSE |
| 2.0 SCOPE |
| The vendor shall deliver two (2) new Oil/Coolant Mist Collectors that meet the following minimum requirements: |
| 4.0 DELIVERABLES |