NEC Ft. Leonard Wood, MO

Introduction:

The Fort Leonard Wood Network Enterprise Center (NEC) Land Mobile Radio (LMR) Towers require numerous structural repairs to meet FAA and Army safety standards.

Scope of Work Contractor shall provide all management, tools, supplies, equipment, labor, and furnish all materials necessary to perform corrective maintenance on the LMR towers located at: Building 1000, MP Hill, and Range Control on Fort Leonard Wood.

Place of Performance Fort Leonard Wood, Missouri:

Building 1000 LMR Tower

MP Hill LMR Tower

Range Control LMR Tower Work Requirements

1. Building 1000 LMR Tower Site 150’ self-supported

a. The Contractor shall

i. Repair grounding on waveguide/ice bridge

ii. Properly ground fence

iii. Provide and install RF radiation warning, and high voltage broadcast equipment signs

iv. Repair tower’s original coating

v. Repair/Replace structure/section bolts and pal/lock nuts

vi. Correct spacing on existing coax hangers and install missing line hangers

vii. Repair/Replace existing antenna mounting hardware

2. MP Hill LMR Tower Site 120’ self-supported

a. The Contractor Shall

i. Properly ground fence

ii. Provide and install RF radiation warning, and high voltage broadcast equipment signs

iii. Repaint entire tower FAA Daymark requirement

iv. Paint feedlines located on outside of tower

v. Repair/Replace bent, rusty, damaged tower diagonals

vi. Repair/Replace structural/section bolts

vii. Install safety climb device

viii. Repair/Replace missing or bent ladder rungs, climbing pegs, or sections

ix. Properly secure feedlines

x. Install lightning rod

3. Range Control LMR Tower Site 260’ Guyed-support

a. The Contractor Shall

i. Install missing buss bars

ii. Properly ground anchor heads

iii. Repair grounding on waveguide/ice bridge

iv. Properly ground waveguide/coax on top and bottom of run

v. Properly ground fence

vi. Provide and install RF radiation warning, and high voltage broadcast equipment signs

vii. Properly align anchors with tower legs and center

4. Contractor shall adhere to guidelines established in the Telecommunications Industry Association Structural Standard publication TIA-222-H, dated Oct 5th 2017, and the Army Safety Program AR385-10

5. Contractor will coordinate with the FLW-NEC POC on date and times of arrival to Fort Leonard Wood

a. Contractor shall provide the FLW-NEC POC with proper documentation for technicians entry onto Fort Leonard Wood

i. FLW-NEC POC will provide what information is needed after contract award

Quality Assurance

1. The Government will monitor the Contractor’s performance while onsite

Deliverables

1. A job site walk through is required to be performed with Network Enterprise Center personnel before any work is to start.

2. The Contractor shall keep the quality assurance inspector apprised of any issues at the worksites. POC Andrew Kirk @ 573-563-8298 or andrew.s.kirk.civ@army.mil.