This document outlines a performance work statement and contract opportunity for an upgraded Electronic System Test Set for the Royal Saudi Air Force. The opportunity is a sole source award to Advanced Electronics Company Limited to provide regression testing, material, software, and labor to upgrade seven Electronic System Test Stations from an A31U18240-2 configuration to an A31U18240-3 configuration, and then from an A31U18240-3 configuration to an A31U18240-4 configuration. The effort will include familiarization training, regression testing, and travel, and has a period of performance of 24 months from award. The Department of the Air Force Materiel Command Lifecycle Management Center at Robins Air Force Base is the contracting agency.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Solicitation.pdf | ||
| DD1423ESTSModernizationA003.pdf | ||
| DD1423ESTSModernizationA001.pdf | ||
| DD1423ESTSModernizationA005.pdf | ||
| DD1423ESTSModernizationA002.pdf | ||
| DD1423ESTSModernizationA004.pdf | ||
| DD1423ESTSModernizationA006.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Performance-based Work Statement for
Royal Saudi Air Force Electronic System Test Set
FD2060-20-31865
15 May 2020
Basic
1.0 Description of Services
1.1 Objective: The purpose of this PWS is to provide the Royal Saudi Air Force (RSAF) with an upgraded Electronic System Test Set (ESTS). The RSAF currently use an A31U18240‐2 ESTS configuration, and this PWS shall provide the scope to upgrade and install the A31U18240‐3 and A31U18240‐4 configuration (frequently referred to as ‐3 and ‐4, respectively), as well as familiarization training, regression testing, and travel.
1.2 Benefit to the United States Air Force: This acquisition will benefit the USAF by meeting the goals defined with the security assistance for Foreign Military Sales programs and United States Government foreign policy.
1.3 Background: The RSAF has seven (7) ESTS stations. One is located at Science and Engineering Services (SES) LLC, Huntsville AL. The other six (6) are located at RSAF facilities in the Kingdom of Saudi Arabia. All ‐3 and ‐4 configuration kits, as well as some spares, were procured under the previous ESTS contract, FA8505‐11‐D‐0002‐0006. These kits will be considered either Contractor Furnished Equipment (CFE) or Government Furnished Property (GFP) under this follow on contract and will be sold off under this effort. Note Appendix B and C.
2.0 Services Summary
Performance Objective PWS Reference Performance Threshold
Provide Timely Completion/Delivery
4.1.1, 4.3 The contractor shall complete the ‐3 and ‐4 ESTS modernization program IAW USAF T.O.s or Contractor RIIs within 24 months from the award of this task order.
Provide Quality Assurance 4.2.1, 5.9 The contractor shall ensure that upgraded configurations shall be in accordance with authorized T.O.’s and/or OEM specifications.
These upgraded stations shall receive certification as a result of having passed screening/test/inspection with 100% successful results. Contractor shall provide screening/test/inspection reports to USAF upon request.
Request for Assistance 4.1.3 The Contractor’s program management and engineering team shall respond to Government technical requests for assistance within 72 hours. Follow‐up assistance, if required, shall be provided by the suspense date acceptable to the Government.
Provide Timely and Accurate Delivery of Data/Document
4.2.1 The contractor shall deliver CDRLs on the 5th
calendar day of each month. There shall be no more than one (1) late submission of data/document(s) for the life of this contract.
The Contractor shall notify the USG if the delivery of any data/document will not meet the scheduled delivery date. Each document shall contain no more than three (3) errors.
Adherence to Contractor Quality Management System
(QMS)
5.9 100% compliance with the QMS is required.
3.0 Government Property
3.1 Contractor Responsibility: The contractor shall be responsible for Government property in accordance with the Federal Acquisition Regulation (FAR) and as specified in the contract/order.
3.2 Government Property to be Provided: The USG shall provide access to the six stations within Saudi Arabia, as well as Line Replaceable Units (LRUs) for regression testing as requested. Requests for LRUs shall be made one month in advance of need. The contractor shall also maintain and upgrade the ESTS station located at SES‐I in Huntsville AL. CFE is identified in Appendix B. GFP is identified in Appendix C. The contractor will be granted access to the ESTS stations in‐ Kingdom as required to complete the regression testing and station upgrades. These stations will remain under RSAF possession.
The RSAF ESTS equipment located at the Science and Engineering Services, Inc. (SES‐I), facility in Huntsville, AL will be provided to contractor for various configuration upgrades and LRU testing. RSAF GFE to include ITAs, ancillary equipment and LRUs listed in Appendix B will be maintained in serviceable condition at the SES‐I facility in Huntsville, Alabama. Upgrade support may require access to additional items such as, but not limited to, Portable Automatic Test Equipment Calibrator (PATEC), Tester Replaceable Units (TRUs), Line Replaceable Units (LRUs), ancillary equipment, test equipment, special tools, computer software, Test Program Source (TPS)/diagnostic code, Test Requirements Documentation (TRD), and engineering data or drawings (Joint Engineering Data Management Information and Control System (JEDMICS)) provided by the USG upon request.
4.0 Technical Requirements
4.1 Period and Place of Performance
4.1.1 Contract/Order Period of Performance: This contract shall be complete within 24 months of the award date.
4.1.2 Place of Performance: These services shall be performed at the RSAF Central Maintenance Facilities (CMF) within the Kingdom of Saudi Arabia, and the Science and Engineering (SES) facility in Huntsville, Alabama. The contractor will be required to upgrade the RSAF ESTS equipment located at the SES facility and in the Kingdom of Saudi Arabia. The services shall be completed without hands‐on assistance from the RSAF or USAF. The contractor will be provided access to RSAF facilities as required in order to perform these services. Contractor personnel who require access must adhere to security procedures and requirements of that facility/installation.
4.1.3 The Contractor shall provide all program management and engineering to manage the upgrade of ESTS in accordance with this PWS. The Contractor’s program management and engineering team shall respond to Government technical requests for assistance within 72 hours. Follow‐up assistance, if required, shall be provided by the suspense date identified by the Government.
4.1.3.1 Program Management Reviews and Technical Interchange Meetings: The contractor shall host quarterly CONUS based Program Management Reviews. The contractor shall host virtual weekly status meetings as requested by the Program Manager. The contractor shall record minutes and action items from these meetings. (CDRL A006 DI‐ADMN‐ 81505)
4.2 Contract Data Requirements List (CDRL)
CDRL Title DID
A001 Monthly Status Report DI‐MGMT‐80227
A002 Acceptance Test Plan DI‐NDTI‐80566A
A003 Integrated Master Schedule DI‐MGMT‐81861
A004 Quality Control Plan DI‐QCIC‐81722
A005 Test/Inspection Report (Regression) DI‐NDTI‐80809B
A006 Record of Meeting/Minutes DI‐ADMN‐81505
4.2.1 Quality and Receipt of CDRL Deliverable: CDRL deliverables shall be submitted via Wide Area WorkFlow (WAWF) and submitted directly to the team member(s) identified on the CDRL. The contractor shall deliver CDRLs on the 5th calendar day of each month. There shall be no more than one (1) late submission(s) of data/document(s) for the life of this contract. The contractor shall notify the government if the delivery of any data/document will not meet the scheduled delivery date. Each document shall contain no more than three (3) errors. The monthly status report (CDRL A001 DID‐MGMT‐80227) shall include the funds expended per Contract Line Item Number (CLIN) and Accounting Classification Reference Number (ACRN), total remaining funds, and funds obligated.
4.3 ESTS ‐3 and ‐4 Configuration Upgrade: The RSAF currently use an A31U18240‐2 ESTS configuration. The contractor shall provide all regression testing, material, software, and labor to upgrade seven (7) ESTS stations from A31U18240‐2 configuration to the A31U18240‐3 configuration, to be completed in accordance with (IAW) any of the following: the United States Air Force (USAF) Technical Order (T.O.) or Contractor Retrofit Installation Instructions (RIIs). Once this is complete, the contractor shall provide all regression testing, material, software, and labor to upgrade the same seven (7) ESTS stations from A31U18240‐3 to the A31U18240‐4 configuration IAW with the USAF Technical Order or Contractor RIIs.
4.3.1 The contractor shall include all technical orders and operator’s manuals required to operate and sustain the upgraded ESTS equipment. The upgrade to the ESTS equipment shall maintain the RSAF ESTS configuration common with that of the USAF ESTS as much as possible. The contractor shall ensure all ESTS upgrades are technically acceptable to the USG. The contractor shall deliver all required spares, cables, harnesses, connectors, et cetera purchased under contract FA8505‐11‐D‐0002‐0006 (see Appendix B) upon government request. The deliverable of this phase of the project shall be ESTS stations with repair/test capability and written certification of completion from the contractor.
4.3.2 The contractor shall track and report progress of the program and report on it on a monthly basis (CDRL A001 DI‐ MGMT‐80227) and (CDRL A003 DI‐MGMT‐81861).
4.3.3 The contractor shall deliver an Acceptance Test Plan (ATP) in accordance with CDRL A002. The contractor shall demonstrate to the USG Quality personnel the successful modification of the ‐2 to ‐3 upgrade, as well as the ‐3 to ‐4 upgrade. The USG will use this test plan to evaluate the upgrade for acceptance as an engineering evaluation station for support of regression testing in Saudi Arabia prior to the release of the US Air Force TO to perform the station upgrade.
The ATP shall be subject to USG review and approval (CDRL A002 DI‐NDTI‐80566A). The contractor shall also complete a test/inspection report (CDRL A0005, DI‐NDTI‐80809B), and provide updates as an addendum to the monthly status report (CDRL A001, DI‐MGMT‐80227).
4.4 Familiarization Training: The Contractor shall establish and maintain the operator familiarization training with respects to being able to deliver the ESTS equipment to a ‐3 and ‐4 configuration upgrade. The Contractor will provide “Train the Trainer” instruction. The associated ESTS Upgrade TOs, or the contractor equivalent, shall be used for the training. All training will be accomplished on an upgraded ESTS and will consist of no more than three people at a time.
The Contractor shall conduct a total of four training sessions. The training dates and times will be coordinated at least 5‐ days in advance by the USG.
4.5 Repair: During this effort, repairs may be necessary. The contractor shall repair any failed Test Replaceable Unit, Line Replaceable Units needed for regression testing, PATEC, and other ancillary equipment. The contractor shall submit all repair requests to the USG Contracting Officer and Contracting Officer Representative for review and approval.
4.6 Travel: Travel by contractor personnel shall be conducted in accordance with FAR 31.205‐46, Travel Costs. Travel requests shall be made in advance and prior to scheduling or booking. Requests shall be submitted to the USG program manager for approval and authorized by the USG contracting officer at least fourteen (14) calendar days prior to the proposed travel departure date. Costs for transportation shall be in accordance with the Joint Travel Regulations. The contractor shall provide trip reports for each approved travel as an addendum to the monthly status report. The contractor shall make arrangements for conference rooms for program management reviews. The contractor shall report all travel expenses charged to the contract during the reporting period. Traveler name, associated cost, purpose, mode of transport, and destination shall be reported.
4.7 Additional Spares: The contractor shall provide equivalent spares for the ‐4 configurations.
4.8 Value Added Tax: The contractor shall account for Value Added Tax.
4.9 Obsolescence Management: The contractor shall manage the ESTS upgrade and provide recommendations for equipment in order to meet system requirements. Obsolescence management should be reported in CDRL A001, the DI‐ MGMT‐80227. The USG shall grant authority to the contractor to proceed with any proposed obsolescence solution.
4.9.1 The contractor provide solutions to diminishing manufacturing sources and material shortages (DMSMS) driven issues. The contractor shall ensure all configuration and bill of material data is loaded in Avionics Components Obsolescence Management (AVCOM). The contractor shall validate issues reported by AVCOM and provide logistical support include research to determine the best course of action to mitigate DMSMS issues. All of the parts loaded in AVCOM for the affected systems shall be continuously monitored for changes in status to include supply availability and recommended replacement information. Obsolescence reengineering and replacement of station equipment may be necessary because of obsolescence caused by diminishing manufacturers and vendors during this effort.
5.0 General Information
5.1 Designation of Mission Essential Services During a Crisis: The functional commander or civilian equivalent has determined that all services under this contract are not mission‐essential and shall not continue in the event of a crisis.
5.2 Security Requirements
5.2.1 Security Regulations: Classified/Controlled Unclassified Information. Knowledge and/or generation of classified information and/or Controlled Unclassified Information (CUI) are required for performance of the contract/order. The Contractor shall ensure applicable Contractor personnel have security clearances at the appropriate level. The Contractor shall provide for the protection of classified information as identified in the Saudi F‐15 Security Classification Guide, 1 January 2019, for classified information and materials received or generated as a part of the execution of this contract. All Contractor personnel shall safeguard RSAF classified data and material IAW RSAF requirements, RSAF Security Regulations, and DoD contract Security Classification Specifications. The Contractor and the Contractor’s employees shall not divulge to any foreign government or to any unauthorized person any classified information of the Saudi Arabian Government or agencies thereof, which may become known during the performance of this contract.
5.2.2 Security Clearance: The contractor shall ensure all applicable personnel have security clearances at the secret level for accomplishment of contract requirements. The security clearance shall be obtained in accordance with the applicable Security Aspect Letter. Contractor personnel whose clearances have been suspended or revoked shall immediately be denied access to classified information and/or Controlled Unclassified Information (CUI) and classified items. The Contractor shall make a reasonable effort to continue performance of tasks under the contract in compliance with the change in security classification in accordance with FAR 52.204‐2, Security Requirements.
5.2.3 Security Incident or Violation: The contractor shall immediately notify the Government Security Office of any potential or actual security incident or violation.
5.2.4 Operations Security (OPSEC): The Contractor shall ensure personnel, information, systems, property, facility and international security requirements are met. The Contractor shall comply with all applicable security regulations and clauses listed in the contract.
5.3 Environmental Management System (EMS): Reserved.
5.4 Agency Affirmative Procurement Programs: In accordance with FAR 23.404, Agency Affirmative Procurement Programs, 100% of purchases of Environmental Protection Agency (EPA)‐designated products included in the Comprehensive Procurement Guidelines (CPG) list [http://www.epa.gov/cpg/products.htm] and/or United States Department of Agriculture (USDA)‐designated products included in the bio‐based product listings [http://www.biopreferred.gov] shall, at a minimum, meet the EPA or USDA standards for recovered materials or bio‐ based content, respectively, unless an item cannot be acquired competitively within a realistic timeframe, meet appropriate performance standards, and/or be acquired at a reasonable price.
5.5 Safety Requirements
5.5.1 Contractor Compliance: The contractor shall comply with all rules and regulations within the Kingdom of Saudi Arabia regarding health regulations.
5.5.2 Mishap Notification/Investigation: The contractor shall report mishaps involving damage or injury to program interests. Damage or injury includes property damage and/or personnel injury caused by program operations. The contractor shall ensure the Government is notified of mishaps by contacting the Government Program Manager within 2 business days. The contractor shall cooperate with safety investigations.
5.6 Inspection of Services: In accordance with the Inspection of Supply/Services clause(s) identified in the contract/order, the Government reserves the right to inspect Contractor performance.
5.7 Contractor Manpower Reporting: In accordance with 10 United States Code 2330a, the Contractor shall provide an annual count of contractor/subcontractor personnel performing work for each fiscal year if the DoD is the requiring activity and if the acquisition is in excess of $3,000,000.00. The Contractor shall report all Contractor labor hours, including subcontractor labor hours, required for performance of the services provided under the contract in the Enterprise‐wide Contractor Manpower Reporting Application (eCMRA). Reporting shall be conducted for each fiscal year, which extends October 1 through September 30. While inputs may be made any time during the fiscal year, all data shall be reported no later than October 31 of the following fiscal year. The Contractor shall establish a record for the contract/order in eCMRA no later than 30 calendar days after contract/order award. The Contractor shall enter Order Data, Contact Data and Location Data. Data for Air Force service requirements must be input at the Air Force
CMRA link. Additional information and user manuals for government personnel and contractors are available at the Army CMRA link at http://www.ecmra.mil.The Contract Manpower Reporting requirement applies only to acquisitions using U.S. Government appropriated funds; therefore, the Contract Manpower Reporting requirement does not apply.
5.8 Invoicing/Payment and Receipt/Acceptance: The Contractor shall submit/process payment requests and receipt/acceptance documents via WAWF.
5.9 Quality Control Plan/Quality Management System (QMS): The Contractor shall ensure the quality of services through a quality and inspection system. The contractor shall meet AS 9100, AS 9110, and ISO 9001 requirements. The Contractor shall submit a Quality Control Plan (QCP) addressing detection of quality program problems and defects, identification of root causes for quality related problems/defects, correction of root causes related to detected problems/defects, and follow‐up measures to ensure quality related problems/defects do not recur. The plan shall include the schedule of quality assurance/control inspections planned by the Contractor. 100% compliance with the QMS is required. The Quality Control Plan, CDRL A004 DI‐QCIC‐81722, should be an addendum to the CDRL A001 monthly status report.
5.10 Trafficking in Persons: The Contractor shall comply in accordance with the FAR and applicable supplements and shall be in compliance with all applicable guidance and clauses listed in the contract as it relates to Trafficking in Persons. Additional information about Trafficking in Persons is available at the site for the Department of State’s Office to Monitor and Combat Trafficking in Persons. Refer to http://www.state.gov/j/tip
6.0 Appendices
6.1 Appendix A, References
Publication Title of Publication Date of Publication
JTR The Joint Travel Regulations
October 2012 http://www.defensetravel.dod.mil/site/travelreg .cfm
6.2 Appendix B, Contractor Furnished Property
The RSAF has six (6) of their seven (7) ESTS systems located at the Centralized Maintenance Facility (CMF), King Khalid Air Base, Saudi Arabia. Under contract FA8505‐11‐D‐0002‐0006, the seventh ESTS, Serial No. 044 was provided to SES as GFE to perform regression testing of RSAF unique LRUs. Appendix C identifies the ESTS equipment provided to SES, to be used on the follow‐on effort.
In addition to performing regression testing under the previous contract, SES procured Tester Replaceable Units (TRUs) as under the ESTS Modernization Program. These TRUs comprise the CFE of A31U18240‐3 Upgrade Kit, A31U18240‐4 Upgrade Kit, and Spares Sets. Appendix D identifies the TRUs which comprise the Upgrade Kits and Spares Sets. The following table identifies the CFE Kit and spares quantities and location.
Item Quantity Procured
RSAF CMF
Location
SES
Location
COMMENTS
A31U18240-3 Upgrade Kit 10 8 2 SES ‐ One ‐3 Kit installed in STA044, one spare
Spares Sets - Six (6) TRUS 10 8 2 SES ‐ Two spares sets for
A31U18240-4 Upgrade Kit 8 0 8 SES ‐ One ‐4 Kit installed in STA044
Counter Timer Digitizer (CTD) 10 0 10 Not Regression Tested
High Speed Digital Word Generator (HSDWG)
30 0 30 Not Regression Tested
6.3 Appendix C, Government Furnished Property
Appendix C identifies the ESTS equipment, special tooling, and special test equipment provided to a SES under contract FA8505‐11‐D‐0002‐0006 for use on the RSAF ESTS Modernization Program.
RSAF ESTS GFE Inventory
Line Item
Nomenclature Part Number Serial Numbers Qty Comment Case # Asset #
1 ITA 1 129A541-1 AD035 1 ITA # 1 122084
2 ITA 3 A31U18440-1 M021 1 ITA # 3 122136
ITA 3 Self Test Unit A31U18492-1 M021 1 122136-1
3 ITA 4 195A454-1 AD017 1 ITA # 4 122134
ITA 4 Self Test Unit 205A502-1 AD017 1 122134-1
4 ITA 5 195A455-1 AD006 1 ITA # 7 122089
ITA 5 Self Test Plate 197A317-1 AD006 1 122089-1
5 ITA 6 195A456-1 AD027 1 Stand-Alone 122096 ITA 6 Self Test Unit 205A572-1 AD027 1 122096-1
6 ITA 7 195A457-1 AD011 1 ITA # 6 122091
ITA 7 Self Test Plate 205A573-1 AD011 1 122091-1
7 ITA 9 A06G3590-1 0010 1 ITA # 12 122090
ITA 9 Self Test Unit A06G3602-1 0010 1 122090-1
8 ITA 10 A06G3591-2 0009 1 ITA # 13 122133
Self Test Unit A06G3601-1 0009 1 122133-1
9 ITA R1 A31U18660-1 M003 1 ITA # 8 122135
ITA R1 Self Test Unit A31U18661-1 M003 1 122135-1
10 ITA R2 A31U18710-1 M003 1 ITA # 9 122088
ITA R2 Self Test Unit A31U18711-1 M003 1 122088-1
11 ITA R3 A31U18750-1 M006 1 ITA # 10 121132
12 ITA R4 A06G3485-1 0007 1 ITA # 11 122097
ITA R4 Self Test Unit A06G3493-1 0007 1 122097-1
13 HF 1 195A801-1 AD010 1 HF # 1 122087
14 HF 2 195A802-1 AD001 1 HF # 2 122086
15 HF 4 195A804-1 AD014 1 HF # 2 122098
16 TPS 43 Air Plenum 195A458 non serialized item
17 HF 6 195A806-1 AD008 1 HF # 3 122128
18 HF 8 195A808-1 AD009 1 HF # 3 122129
19 HF 10 A31U18490-1 M029 1 HF # 4 122130
20 HF R1 A31U18662-1 M004 1 HF # 5 122131
21 HF R2 J06G0536-1 0007 1 HF # 5 122099
22 TPS R2 Adapter Assy A31U18675-1 M007 1 HF # 5 122100
23 AMDTS 18906300001 9909 1 Stand-Alone 122093
24 PPTS 48700-101 9912 1 Stand-Alone 122095
25 Rate Table 195A829-2 118103-1 1 Stand-Alone 122094
26 Cable Set A 195A700-1 AD0043 1 set Cable # 8 N/A
Cable AW01 195A664-1 AD0043 1 ea N/A Cable AW02 195A665-1 AD0043 1 ea N/A Cable AW03 195A666-1 AD0043 1 ea N/A Cable AW04 195A667-1 AD0043 1 ea N/A
27 Cable Set B 195A760-1 AD052 Mixed S/N Set
1 set Cable # 8 N/A
Accessory Case 197A155-1 AD052 1 ea in set N/A Adapter Assy, BD01-A 197A400-1 non serialized item 1 ea in set N/A
Adapter Assy, BD01-B 197A065-1 960723-108 1 of 3 in set N/A Adapter Assy, BD01-B 197A065-1 960723-072 2 of 3 in set N/A Adapter Assy, BD01-B 197A065-1 960723-067 3 of 3 in set N/A Adapter Assy, BD03 197A159-1 non serialized item 1 ea in set N/A
Adapter Assy, BD04 197A160-1 non serialized item
1 ea in set N/A
Adapter Assy, BD05 197A163-1 non serialized item
1 ea in set N/A
Adapter Assy, BD07 197A111-1 non serialized item
1 ea in set N/A
Adapter Assy, BD08 197A091-1 AD104 1 of 2 in set N/A Adapter Assy, BD08 197A091-1 AD105 2 of 2 in set N/A Adapter Assy, BD09 197A092-1 AD104 1 of 2 in set N/A Adapter Assy, BD09 197A092-1 AD105 2 of 2 in set N/A Adapter Assy, BD10 197A162-1 non serialized item 1 of 2 in set N/A
Adapter Assy, BD10 197A162-1 non serialized item
2 of 2 in set N/A
Adapter Assy, BD11 197A039-1 013 1 ea in set N/A Adapter Assy, BD12 197A033-1 non serialized item 1 ea in set N/A
Adapter Assy, BD13 205A633-1 non serialized item
1 ea in set N/A
Adapter Assy, BD14 205A630-1 non serialized item
1 ea in set N/A
Adapter Assy, BD15 205A631-1 non serialized item
1 ea in set N/A
Adapter Assy, BHN1 197A157-1 3318A11656 1 ea in set N/A Cable Assy, BW01 195A747-1 AD052 1 ea in set N/A Cable Assy, BW02 195A695-1 non serialized item 1 of 9 in set N/A
Cable Assy, BW02 195A695-1 non serialized 2 of 9 in set N/A
Cable Assy, BW02 195A695-1 non serialized item 3 of 9 in set N/A
Cable Assy, BW02 195A695-1 non serialized item
4 of 9 in set N/A
Cable Assy, BW02 195A695-1 non serialized item
5 of 9 in set N/A
Cable Assy, BW02 195A695-1 non serialized item
6 of 9 in set N/A
Cable Assy, BW02 195A695-1 non serialized item
7 of 9 in set N/A
Cable Assy, BW02 195A695-1 non serialized item
8 of 9 in set N/A
Cable Assy, BW02 195A695-1 non serialized item
9 of 9 in set N/A
Cable Assy, BW03 197A053-1 AD203 1 of 4 in set N/A Cable Assy, BW03 197A053-1 AD206 2 of 4 in set N/A Cable Assy, BW03 197A053-1 AD207 3 of 4 in set N/A Cable Assy, BW03 197A053-1 AD205 4 of 4 in set N/A Cable Assy, BW04 195A748-1 AD062 1 ea in set N/A Cable Assy, BW06 197A257-1 AD052 1 ea in set N/A Cable Assy, BW07 197A258-1 AD052 1 ea in set N/A Cable Assy, BW08 197A259-1 AD052 1 ea in set N/A Cable Assy, BW09 197A054-1 AD052 1 ea in set N/A Cable Assy, BW10 195A677-1 AD052 1 ea in set N/A Cable Assy, BW11 195A540-1 AD001 1 ea in set N/A Cable Assy, BW12 197A034-1 AD052 1 ea in set N/A
28 Cable Set C A31U18700-1 M007 1 set Cable # 12 N/A Accessory Case, RSAF A31U18748-1 non serialized item 1 ea in set N/A
Cable Assy, CW01 A31U18701-1 M007 1 ea in set N/A Cable Assy, CW03 A31U18703-1 M007 1 ea in set N/A Cable Assy, CW04 A31U18704-1 M007 1 ea in set N/A Cable Assy, CW05 A31U18704-2 M007 1 ea in set N/A Cable Assy, CW06 A31U18704-3 M007 1 ea in set N/A Cable Assy, MISC A31U18199-1 non serialized item 1 of 2 in set N/A
Cable Assy, MISC A31U18199-1 non serialized item
2 of 2 in set N/A
Adapter, HN / N 29JP115-1 non serialized item
1 of 2 in set N/A
Adapter, HN / N 29JP115-1 non serialized item
2 of 2 in set N/A
Adapter, Keyed TNC / N 2234000A001-non serialized item
1 of 2 in set N/A
Adapter, Keyed TNC / N 2234000A001-non serialized item
2 of 2 in set N/A
Mini Grabber 4826-0 non serialized item
1 of 4 in set N/A
Mini Grabber 4826-0 non serialized item
2 of 4 in set N/A
Mini Grabber 4826-0 non serialized item
3 of 4 in set N/A
Mini Grabber 4826-0 non serialized
4 of 4 in set N/A
29 Cable Set 01 195A701-1 AD005 1 set Cable # 1 N/A
Cable Assy, 1W01 195A436-1 AD005 1 ea in set N/A Cable Assy, 1W02 195A444-1 AD005 1 ea in set N/A Cable Assy, 1W03 195A453-1 AD005 1 ea in set N/A Cable Assy, 1W04 195A560-1 AD005 1 ea in set N/A Cable Assy, 1W05 195A561-1 AD005 1 ea in set N/A
30 Cable Set 04 195A732-1 AD016 1 set Cable # 1 N/A Cable Assy, 4W01 195A758-1 AD016 1 ea in set N/A Cable Assy, 4W02 195A757-1 AD016 1 ea in set N/A
31 Cable Set 06 195A706-1 AD033 1 set Cable # 1 N/A
Cable Assy, 6D01 197A404-1 AD033 1 ea in set N/A Cable Assy, 6W01 195A761-1 AD033 1 ea in set N/A
32 Cable Set 07 195A707-1 AD020 1 set Cable # 3 N/A Cable Assy, 7W01 195A770-1 AD020 1 ea in set N/A Cable Assy, 7W02 195A771-1 AD020 1 ea in set N/A Cable Assy, 7W03 195A772-1 AD020 1 ea in set N/A Cable Assy, 7W04 195A773-1 AD020 1 ea in set N/A Cable Assy, 7W05 195A762-1 AD020 1 ea in set N/A Cable Assy, 7W06 195A763-1 AD020 1 ea in set N/A Cable Assy, 7W07 195A764-1 AD020 1 ea in set N/A Cable Assy, 7W08 195A765-1 AD020 1 ea in set N/A Cable Assy, 7W09 195A766-1 AD020 1 ea in set N/A Cable Assy, 7W10 195A767-1 AD020 1 ea in set N/A Cable Assy, 7W11 195A768-1 AD020 1 ea in set N/A Cable Assy, 7W12 195A769-1 AD020 1 ea in set N/A
33 Cable Set 08 195A731-1 AD0015 1 set Cable # 5 N/A Cable Assy, 8W01 195A776-1 AD0015 1 ea in set N/A Cable Assy, 8W02 195A777-1 AD0015 1 ea in set N/A Cable Assy, 8W03 195A778-1 AD0015 1 ea in set N/A Cable Assy, 8W04 195A779-1 AD0015 1 ea in set N/A Cable Assy, 8W05 195A781-1 AD0015 1 ea in set N/A Cable Assy, 8W06 195A782-1 AD0015 1 ea in set N/A
34 Cable Set 09 195A708-1 AD015
1 set Cable # 3 N/A
Cable Assy, 9W01 195A783-1 AD015 1 ea in set N/A Cable Assy, 9W02 195A784-1 AD015 1 ea in set N/A Cable Assy, 9W04 195A785-1 AD018 1 ea in set N/A Cable Assy, 9W05 195A786-1 AD015 1 ea in set N/A Cable Assy, 9W06 195A787-1 AD015 1 ea in set N/A Cable Assy, 9W07 195A788-1 AD015 1 ea in set N/A
35 Cable Set 10 195A730-1 AD009 1 set Cable # 3 N/A Cable Assy, 10W01 195A676-1 AD009 1 ea in set N/A Cable Assy, 10W02 195A675-1 AD009 1 ea in set N/A Cable Assy, 10W04 195A674-1 AD009 1 ea in set N/A Cable Assy, 10W05 195A673-1 AD009 1 ea in set N/A Cable Assy, 10W06 195A672-1 AD009 1 ea in set N/A Cable Assy, 10W07 195A671-1 AD009 1 ea in set N/A Cable Assy, 10W08 195A670-1 AD009 1 ea in set N/A Cable Assy, 10W09 195A669-1 AD009 1 ea in set N/A Cable Assy, 10W10 195A668-1 AD009 1 ea in set N/A Cable Assy, 10W11 205A713-1 AD009 1 ea in set N/A
36 Cable Set 11 195A709-1 AD016 1 set Cable # 5 N/A Cable Assy, 11W03 195A792-1 AD016 1 ea in set N/A Cable Assy, 11W04 195A793-1 AD016 1 ea in set N/A Cable Assy, 11W05 195A794-1 AD016 1 ea in set N/A Cable Assy, 11W06 195A795-1 AD016 1 ea in set N/A Cable Assy, 11W07 195A796-1 AD016 1 ea in set N/A
37 Cable Set 12 195A710-1 AD008 1 set Cable # 9 N/A Cable Assy, 12D01-1 195A821-1 AD008 1 ea in set N/A Cable Assy, 12W01-1 195A564-1 AD008 1 ea in set N/A Cable Assy, 12W01-2 195A681-1 AD008 1 ea in set N/A Cable Assy, 12W02 195A682-1 AD008 1 ea in set N/A
38 Cable Set 13 195A711-1 AD008 1 set Cable # 9 N/A Cable Assy, 13D01-1 195A822-1 AD008 1 ea in set N/A Cable Assy, 13W01-1 195A576-1 AD008 1 ea in set N/A Cable Assy, 13W01-2 195A577-1 AD008 1 ea in set N/A Cable Assy, 13W02 195A579-1 AD008 1 ea in set N/A
39 Cable Set 16 195A713-1 AD032 1 set Cable # 6 N/A
Cable Assy, 16W01 195A580-1 AD032 1 ea in set N/A
40 Cable Set 17 195A714-1 AD012 1 set Cable # 6 N/A Cable Assy, 17W01 195A562-1 AD012 1 ea in set N/A Cable Assy, 17W02 195A563-1 AD012 1 ea in set N/A Cable Assy, 17W03 195A600-1 AD012 1 ea in set N/A Cable Assy, 17W04 195A605-1 AD012 1 ea in set N/A Cable Assy, 17W05 195A614-1 AD012 1 ea in set N/A Cable Assy, 17W06 195A615-1 AD012 1 ea in set N/A
41 Cable Set 18 195A715-1 AD012 1 set Cable # 7 N/A Cable Assy, 18W01 195A619-1 AD012 1 ea in set N/A Cable Assy, 18W02 195A622-1 AD012 1 ea in set N/A Cable Assy, 18W03 195A624-1 AD012 1 ea in set N/A Cable Assy, 18W04 195A629-1 AD012 1 ea in set N/A Cable Assy, 18W05 195A632-1 AD012 1 ea in set N/A Cable Assy, 18W06 195A634-1 AD012 1 ea in set N/A
42 Cable Set 20 195A717-1 AD010 1 set Cable # 6 N/A Cable Assy, 20W01 195A689-1 AD010 1 ea in set N/A
43 Cable Set 23 195A720-1 AD019 1 set Cable # 1 N/A Cable Assy, 23W01 195A641-1 AD019 1 ea in set N/A Cable Assy, 23W02 195A642-1 AD019 1 ea in set N/A Cable Assy, 23W03 195A647-1 AD019 1 ea in set N/A Cable Assy, 23W04 195A439-1 AD019 1 ea in set N/A
44 Cable Set 25 195A722-1 AD014 1 set Cable # 6 N/A Cable Assy, 25W01 195A581-1 AD014 1 ea in set N/A Cable Assy, 25W02 195A582-1 AD014 1 ea in set N/A Cable Assy, 25W03 195A583-1 AD014 1 ea in set N/A Cable Assy, 25W04 195A584-1 AD014 1 ea in set N/A Cable Assy, 25W05 195A585-1 AD014 1 ea in set N/A
45 Cable Set 26 195A723-1 AD019 1 set Cable # 6 N/A Cable Assy, 26W01 195A590-1 AD019 1 ea in set N/A Cable Assy, 26W02 195A591-1 AD019 1 ea in set N/A
46 Cable Set 27 195A724-1 AD013 1 set Cable # 1 N/A Cable Assy, 27W01 195A592-1 AD013 1 ea in set N/A Cable Assy, 27W02 195A593-1 AD013 1 ea in set N/A Cable Assy, 27W03 195A594-1 AD013 1 ea in set N/A Cable Assy, 27W05 195A596-1 AD013 1 ea in set N/A
47 Cable Set 28 195A725-1 AD010 1 set Cable # 1 N/A Cable Assy, 28W01 195A826-1 AD010 1 ea in set N/A Cable Assy, 28W02 195A827-1 AD010 1 ea in set N/A Cable Assy, 28W03 195A696-1 AD010 1 ea in set N/A Cable Assy, 28W04 195A697-1 AD010 1 ea in set N/A Cable Assy, 28W05 195A698-1 AD010 1 ea in set N/A
48 Cable Set 30 195A726-1 AD008 1 set Cable # 6 N/A Cable Assy, 30W01 195A684-1 AD008 1 ea in set N/A Cable Assy, 30W02 195A685-1 AD008 1 ea in set N/A
49 Cable Set 31 195A727-1 AD010 1 set Cable # 6 N/A Cable Assy, 31W01 195A597-1 AD010 1 ea in set N/A Cable Assy, 31W02 195A598-1 AD010 1 ea in set N/A
50 Cable Set 33 195A728-1 AD020 1 set Cable # 1 N/A Cable Assy, 33W01 195A652-1 AD020 1 ea in set N/A Cable Assy, 33W09 195A656-1 AD020 1 ea in set N/A Cable Assy, 33W10 195A657-1 AD020 1 ea in set N/A
51 Cable Set 35 195A733-1 AD010 1 set Cable # 1 N/A Cable Assy, 35W01 195A699-1 AD010 1 ea in set N/A
52 Cable Set 36 195A559-1 AD017
1 set Cable # 1 N/A
Cable Assy, 36W01 195A814-1 AD017 1 ea in set N/A Cable Assy, 36W02 195A815-1 AD017 1 ea in set N/A Cable Assy, 36W03 195A816-1 AD012 1 ea in set N/A
53 Cable Set 37 195A753-1 AD011 1 set Sustainer - Set Received with missing 37W03 Cable
Cable # 5 N/A
Cable Assy, 37W03 195A519-1 Missing 1 ea in set N/A Cable Assy, 37W04 195A520-1 AD011 1 ea in set N/A Cable Assy, 37W05 195A528-1 AD011 1 ea in set N/A Cable Assy, 37W06 195A529-1 AD011 1 ea in set N/A Cable Assy, 37W07 195A530-1 AD011 1 ea in set N/A Cable Assy, 37W08 195A531-1 AD011 1 ea in set N/A Cable Assy, 37W09 195A532-1 AD011 1 ea in set N/A
54 Cable Set 38 195A734-1 AD011
1 set Cable # 4 N/A
Cable Assy, 38W04 195A536-1 AD011 1 ea in set N/A Cable Assy, 38W05 195A537-1 AD011 1 ea in set N/A Cable Assy, 38W06 195A538-1 AD011 1 ea in set N/A Cable Assy, 38W07 195A539-1 AD011 1 ea in set N/A Cable Assy, 38W09 195A541-1 AD011 1 ea in set N/A Cable Assy, 38W10 195A542-1 AD011 1 ea in set N/A Cable Assy, 38W12 195A544-1 AD011 1 ea in set N/A Cable Assy, 38W13 195A545-1 AD023 1 ea in set N/A Cable Assy, 38W14 195A546-1 AD016 1 ea in set N/A Cable Assy, 38W16 195A548-1 AD011 1 ea in set N/A Cable Assy, 38W17 195A549-1 AD011 1 ea in set N/A Resistor Box, 38W18 205A540-1 non serialized
1 ea in set N/A
55 Cable Set 39 195A735-1 AD015
1 set Cable # 5 N/A
Cable Assy, 39W01 195A550-1 AD015 1 ea in set N/A Cable Assy, 39W02 195A551-1 AD015 1 ea in set N/A Cable Assy, 39W03 195A552-1 AD015 1 ea in set N/A Cable Assy, 39W04 195A553-1 AD015 1 ea in set N/A Cable Assy, 39W05 195A554-1 AD015 1 ea in set N/A Cable Assy, 39W07 195A565-1 AD051 1 ea in set N/A Cable Assy, 39W08 195A566-1 AD015 1 ea in set N/A Cable Assy, 39W09 205A551-1 AD005 1 ea in set N/A Cable Assy, 39Z01 205A717-1 non-serialized
56 Cable Set 40 195A557-1 AD009 1 set Cable # 2 N/A
Cable Assy, 40W01 195A817-1 AD009 1 ea in set N/A Cable Assy, 40W02 195A818-1 AD009 1 ea in set N/A Cable Assy, 40W03 195A819-1 AD009 1 ea in set N/A Cable Assy, 40W04 195A820-1 AD009 1 ea in set N/A
57 Cable Set 43 A06G3592-1 0009
1 set Cable # 2 N/A
Cable Assy, 43W01 A14G2817-1 0009 1 ea in set N/A Cable Assy, 43W02 A14G2818-1 0009 1 ea in set N/A Cable Assy, 43W03 A14G2819-1 0009 1 ea in set N/A Cable Assy, 43W04 A14G2820-1 0009 1 ea in set N/A Cable Assy, 43W05 A14G2821-1 0009 1 ea in set N/A Cable Assy, 43W06 A14G2822-1 0009 1 ea in set N/A Cable Assy, 43W07 A14G2823-1 0009 1 ea in set N/A Cable Assy, 43W08 A14G2824-1 0009 1 ea in set N/A Cable Assy, 43W09 A14G2825-1 0009 1 ea in set N/A Cable Assy, 43W10 A14G2826-1 0009 1 ea in set N/A Cable Assy, 43W11 A14G2827-1 0009 1 ea in set N/A
Cable Assy, 43W12 A14G2828-1 0009 1 ea in set N/A 58 Load Box, 43A1 A06G3616-1 0014 1 ea in set Should be in ITA
# 1 Case, In standalone box due to size.
Stand-alone 122092
Plug Assy, 43A1P5 A06G3643-1 0009 1 ea in set N/A Shorting Connector, 43A2 A06G3702-1 0008 1 ea in set N/A
59 Cable Set 44 195A744-1 AD016 1 set Cable # 4 N/A Cable Assy, 44W01 195A599-1 AD016 1 ea in set N/A Cable Assy, 44D01 205A600-1 AD016 1 ea in set N/A
60 Cable Set 46 A06G3593-1 0007 1 set Cable # 2 N/A Cable Assy, 46W01 A14G2795-1 0007 1 ea in set N/A Cable Assy, 46W02 A14G2796-1 0007 1 ea in set N/A Cable Assy, 46W03 A14G2797-1 0007 1 ea in set N/A Cable Assy, 46W04 A14G2798-1 0007 1 ea in set N/A Cable Assy, 46W05 A14G2847-2 0007 1 ea in set N/A
61 Cable Set 48 A06G3594-1 0007 1 set Cable # 5 N/A Cable Assy, 48W01 A14G2799-1 0007 1 ea in set N/A Cable Assy, 48W02 A14G2800-1 0007 1 ea in set N/A Cable Assy, 48W03 A14G2801-1 0007 1 ea in set N/A Cable Assy, 48W04 A14G2802-1 0007 1 ea in set N/A Cable Assy, 48W06 A14G2804-1 0007 1 ea in set N/A Cable Assy, 48W07 A14G2805-1 0007 1 ea in set N/A Cable Assy, 48W08 A14G2806-1 0007 1 ea in set N/A Cable Assy, 48W09 A14G2807-1 0007 1 ea in set N/A Cable Assy, 48W10 A14G2808-1 0007 1 ea in set N/A Cable Assy, 48W11 A14G2809-1 0007 1 ea in set N/A Cable Assy, 48W12 A14G2810-1 0007 1 ea in set N/A Cable Assy, 48W13 A14G2811-1 0007 1 ea in set N/A Cable Assy, 48W14 A14G2812-1 0007 1 ea in set N/A Cable Assy, 48W15 A14G2813-1 0007 1 ea in set N/A Cable Assy, 48W16 A14G2846-1 0007 1 ea in set N/A Cable Assy, 48W17 A14G2846-2 0007 1 ea in set N/A Cable Assy, 48W18 A14G2847-1 0007 1 ea in set N/A
62 Cable Set 49 A06G3595-1 0016 1 set Cable # 4 N/A Cable Assy, 49W01 A14G2799-2 0016 1 ea in set N/A Cable Assy, 49W02 A14G2814-1 0016 1 ea in set N/A Cable Assy, 49W06 A14G2815-1 0016 1 ea in set N/A Cable Assy, 49W07 A14G2816-1 0016 1 ea in set N/A Cable Assy, 49W08 A14G2805-2 0016 1 ea in set N/A Cable Assy, 49W09 A14G2806-2 0016 1 ea in set N/A Cable Assy, 49W10 A14G2807-2 0016 1 ea in set N/A Cable Assy, 49W11 A14G2813-2 0016 1 ea in set N/A Cable Assy, 49W12 A14G2846-3 0016 1 ea in set N/A Cable Assy, 49W13 A14G2846-4 0016 1 ea in set N/A Cable Assy, 49W14 A14G2847-3 0016 1 ea in set N/A
63 Cable Set 50 195A741-1 AD013
1 set Cable # 6 N/A
Cable Assy, 50W01 195A691-1 AD013 1 ea in set N/A Cable Assy, 50W02 195A692-1 AD013 1 ea in set N/A Cable Assy, 50W03 195A693-1 AD001 1 ea in set N/A
64 Cable Set 51 195A746-1 AD010
1 set Cable # 7 N/A
Cable Assy, 51W01 195A679-1 AD010 1 ea in set N/A Cable Assy, 51W02 195A759-1 AD010 1 ea in set N/A Cable Assy, 51W03 195A774-1 AD010 1 ea in set N/A Cable Assy, 51W04 195A775-1 AD010 1 ea in set N/A Cable Assy, 51W05 197A008-1 AD010 1 ea in set N/A Cable Assy, 51W06 197A009-1 AD010 1 ea in set N/A Cable Assy, 51W07 197A010-1 AD010 1 ea in set N/A Cable Assy, 51W08 205A803-1 AD010 1 of 3 ea in set N/A
Cable Assy, 51W08 205A803-1 AD032 2 of 3 ea in set N/A Cable Assy, 51W08 205A803-1 AD012 3 of 3 ea in set N/A Cable Assy, 51W26 195A467-1 AD010 1 ea in set N/A Cable Assy, 51D26 205A795-1 AD010 1 ea in set N/A
65 Cable Set 53 195A558-1 AD018 1 set Cable # 7 N/A Cable Assy, 53W01 195A686-1 AD018 1 ea in set N/A Cable Assy, 53W02 195A687-1 AD018 1 ea in set N/A Cable Assy, 53W03 195A688-1 AD018 1 ea in set N/A Cable Assy, 53W04 195A472-1 AD018 1 ea in set N/A Cable Assy, 53W05 205A814-1 AD018 1 ea in set N/A Cable Assy, 53W06 205A815-1 AD018 1 ea in set N/A Cable Assy, 53W07 205A816-1 AD018 1 ea in set N/A Cable Assy, 53W08 205A817-1 AD018 1 ea in set N/A Cable Assy, 53W09 205A818-1 AD018 1 ea in set N/A Cable Assy, 53W10 205A819-1 AD018 1 ea in set N/A 2A4 Cage Extender 205A724-1 AD018 1 ea in set N/A 2A5 Cage Extender 205A725-1 AD018 1 ea in set N/A Guide Post Extender 205A794-1 AD018 1 of 2 ea in set N/A Guide Post Extender 205A794-1 AD018 2 of 2 ea in set N/A
66 Cable Set 54 195A752-1 AD028 1 set Cable # 7 N/A Cable Assy, 54W01 195A780-1 AD028 1 ea in set N/A Cable Assy, 54W02 195A797-1 AD028 1 ea in set N/A Cable Assy, 54W03 195A798-1 AD028 1 ea in set N/A Cable Assy, 54W04 195A799-1 AD028 1 ea in set N/A Cable Assy, 54W05 195A800-1 AD028 1 ea in set N/A
67 Cable Set 55 A06G3596-1 0009 1 set Cable # 7 N/A Cable Assy, 55W01 A14G2829-1 0009 1 ea in set N/A Cable Assy, 55W02 A14G2830-1 0009 1 ea in set N/A Cable Assy, 55W03 A14G2831-1 0009 1 ea in set N/A Cable Assy, 55W04 A14G2852-1 0009 1 ea in set N/A Cable Assy, 55W05 A14G2852-2 0009 1 ea in set N/A Cable Assy, 55W06 A14G2852-3 0009 1 ea in set N/A
68 Cable Set 56 A31U18456-1 M024 1 set Cable # 10 N/A Cable Assy, 56W01 A31U18470-1 M024 1 ea in set N/A Cable Assy, 56W02 A31U18495-1 M024 1 of 2 ea in set N/A Cable Assy, 56W02 A31U18495-1 M024 1 of 2 ea in set N/A
69 Cable Set 58 A31U18458-1 M022 1 set Cable # 10 N/A Cable Assy, 58W01 A31U18475-1 M022 1 ea in set N/A Cable Assy, 58W02 A31U18476-1 M022 1 ea in set N/A Cable Assy, 58W03 A31U18477-1 M022 1 ea in set N/A Cable Assy, 58W04 A31U18478-1 M022 1 ea in set N/A Cable Assy, 58W05 A31U18479-1 M022 1 ea in set N/A Cable Assy, 58W06 A31U18463-1 M022 1 ea in set N/A Cable Assy, 58W07 A31U18464-1 M022 1 ea in set N/A
70 Cable Set 59 A31U18459-1 M021 1 set Cable # 10 and Cable #
N/A
Cable Assy, 59W01 A31U18465-1 M021 1 ea in set N/A Cable Assy, 59W02 A31U18466-1 M021 1 ea in set N/A Cable Assy, 59W03 A31U18467-1 M021 1 ea in set N/A Cable Assy, 59W04 A31U18468-1 M021 1 ea in set N/A Cable Assy, 59W05 A31U18469-1 M021 1 ea in set N/A Cable Assy, 59W06 A31U18441-1 M021 1 ea in set N/A Cable Assy, 59W07 A31U18442-1 M021 1 ea in set N/A Cable Assy, 59W08 A31U18443-1 M021 1 ea in set N/A Cable Assy, 59W09 A31U18444-1 M021 1 ea in set N/A Cable Assy, 59W10 A31U18445-1 M021 1 ea in set N/A Cable Assy, 59W11 A31U18446-1 M021 1 ea in set N/A Cable Assy, 59W12 A31U18447-1 M021 1 ea in set N/A Cable Assy, 59W13 A31U18448-1 M021 1 ea in set N/A
Cable Assy, 59W14 A31U18449-1 M021 1 ea in set N/A Adapter Assy, 59CP01 A31U18747-1 M021 1 ea in set N/A
71 Cable Set 60 A31U18460-1 M018 1 set Cable # 11 N/A Cable Assy, 60W01 A31U18450-1 M018 1 ea in set N/A Cable Assy, 60W02 A31U18451-1 M018 1 ea in set N/A Cable Assy, 60W03 A31U18452-1 M018 1 ea in set N/A Cable Assy, 60W04 A31U18453-1 M018 1 ea in set N/A Cable Assy, 60W05 A31U18454-1 M018 1 ea in set N/A Cable Assy, 60W06 A31U18455-1 M018 1 ea in set N/A Cable Assy, 60W07 A31U18481-1 M018 1 ea in set N/A Cable Assy, 60W08 A31U18482-1 M018 1 ea in set N/A
72 Cable Set 61 A31U18461 M024 1 set Cable # 11 N/A Cable Assy, 61W01 A31U18483-1 M024 1 ea in set N/A Cable Assy, 61W02 A31U18484-1 M024 1 ea in set N/A Cable Assy, 61W03 A31U18485-1 M024 1 ea in set N/A
73 Cable Set 62 A31U39039 A010 1 set SC Cable #
N/A
62W01 Cable A31U39039-1 0010 1 ea in set Cable # 11 N/A
74 Cable Set 63 195A705-1 AD010 1 set Cable # 9 N/A Cable Assy, 63W08 195A515-1 AD010 1 ea in set N/A Cable Assy, 63W09 195A516-1 AD010 1 ea in set N/A Cable Assy, 63WP2 195A449-1 AD010 1 ea in set N/A
75 Cable Set R1 A31U18670-1 M003 1 set Cable # 12 N/A Cable Assy, R1W01 A31U18671-1 M003 1 ea in set N/A Cable Assy, R1W02 A31U18672-1 M003 1 ea in set N/A Cable Assy, R1W03 A31U18673-1 M003 1 ea in set N/A
76 Cable Set R2 A31U18680-1 M003 1 set Cable # 12 N/A Cable Assy, R2W01 A31U18681-1 M003 1 ea in set N/A Cable Assy, R2W02 A31U18682-1 M003 1 ea in set N/A Cable Assy, R2W03 A31U18683-1 M003 1 ea in set N/A
77 Cable Set R4 A31U18720-1 M003 1 set Cable # 12 N/A Cable Assy, R4W01 A31U18722-1 M003 1 ea in set N/A Cable Assy, R4W02 A31U18724-1 M003 1 ea in set N/A
78 Cable Set R5 A31U18730-1 M003 1 set Cable # 12 N/A Cable Assy, R5W01 A31U18731-1 M003 1 ea in set N/A Cable Assy, R5W03 A31U18733-1 M003 1 ea in set N/A Cable Assy, R5W04 A31U18734-1 M003 1 ea in set N/A
79 Cable Set R6 A31U18690-1 M003 1 set Cable # 12 N/A Cable Assy, R6W01 A31U18691-1 M003 1 ea in set N/A Cable Assy, R6W02 A31U18692-1 M003 1 ea in set N/A Cable Assy, R6W03 A31U18689-1 M003 1 ea in set N/A
80 Cable Set R7 A31U18740-1 M003 1 set Cable # 12 N/A Cable Assy, R7W01 A31U18741-1 M003 1 ea in set N/A Cable Assy, R7W02 A31U18742-1 M003 1 ea in set N/A Cable Assy, R7W03 A31U18743-1 M003 1 ea in set N/A Jumper Box, for R7W03 A31U18550-1 non serialized
81 Cable Set R8 A06G3486-1 0007 1 set Cable # 13 N/A
Cable Assy, R8W01 A14G27713-1 0007 1 ea in set N/A Cable Assy, R8W02 A14G27714-1 0007 1 ea in set N/A Cable Assy, R8W03 A14G27715-1 0007 1 ea in set N/A Cable Assy, R8W04 A14G27716-1 0007 1 ea in set N/A Cable Assy, R8W05 A14G27717-1 0007 1 ea in set N/A Cable Assy, R8W06 A14G27718-1 0007 1 ea in set N/A
82 Cable Set R09 A06G3488-1 0007 1 set Cable # 13 N/A Cable Assy, R9W01 A14G2724-1 0007 1 ea in set N/A Cable Assy, R9W03 A14G2726-1 0007 1 ea in set N/A Cable Assy, R9W04 A14G2727-1 0007 1 ea in set N/A Cable Assy, R9W05 A14G2728-1 0007 1 ea in set N/A
83 Cable Set R10 A06G3487-1 0021 1 set Cable # 13 N/A Cable Assy, R10W01 A14G2719-1 0021 1 ea in set N/A Cable Assy, R10W02 A14G2720-1 0021 1 ea in set N/A
84 Cable Set R11 A06G3494-1 0021 1 set Cable # 13 N/A Cable Assy, R11W01 A14G2729-1 0021 1 ea in set N/A Cable Assy, R11W02 A14G2730-1 0021 1 ea in set N/A Cable Assy, R11W04 A14G2731-1 0021 1 ea in set N/A
85 Cable Set M45 205A827-1 AD001 1 set Cable # 4 N/A Cable Assy, 45W01 205A828-1 AD001 1 ea in set N/A Shorting Plug Assy, 45W02 205A829-1 AD001 1 ea in set N/A Cable Assy, Video, 45W03 205A830-1 AD001 1 ea in set N/A Shorting Plug Assy, 45D01 205A831-1 AD001 1 ea in set N/A
86 Oscilloscope PM3390B DM785012 1 ITA # 1 126357 87 Monitor LBO-51 MAC-01 3517073 1 ITA # 1 N/A 88 ITA 8 195A458-1 AD035 1 ea ITA # 7 N/A
6.4 Appendix D, Assemblies and Instrument List
Appendix D identifies the RSAF ESTS Assemblies and Instruments per ESTS System provided as CFE for the TCTO A31U18240‐3 and A31U18240‐4 Upgrade Kits, and Spares for this effort. The Counter Timer Digitizer (CTD), High‐Speed Digital Word Generator (HSDWG), and their associated cables previously purchased under contract FA8505‐11‐D‐0002‐0006 are not included as part of TCTO‐3, TCTO‐4, or Spares.
Item Number Nomenclature PN System Qty
A31U18240-3 UPGRADE KIT
Commented [MJMGUAA1]: What is this? Ask CTR
1 ASSEMBLY, SYNCHRO/RESOLVER PROCESSOR 201119260-10 1
2 CABLE ASSEMBLY, SYNCHRO/RESOLVER PROCESSOR 201119262-10 1
3 ASSEMBLY, DIGITAL TO ANALOG CONVERTER 201119265-10 1
4 CABLE ASSEMBLY, DIGITAL TO ANALOG CONVERTER 201119267-10 1
5 ASSEMBLY, SCANNER MULTIPLEXER 201119224-10 1
6 CABLE ASSEMBLY, SCANNER MULTIPLEXER 201119259-10 1
7 CABLE ASSEMBLY, SCANNER MULTIPLEXER 201119259-30 1
8 ASSEMBLY, ARBITRARY FUNCTION GENERATOR 201119275-10 1
9 AIR IMPEDANCE MODULE 80-634JB-00-6T 3
10 ASSEMBLY, SIGNAL DISTRIBUTION SYSTEM 201119280-10 2
11 CABLE ASSEMBLY, SIGNAL DISTRIBUTION SYSTEM 201119282-10 1
12 CABLE ASSEMBLY, SIGNAL DISTRIBUTION SYSTEM 201119282-30 1
13 CABLE ASSEMBLY, SIGNAL DISTRIBUTION SYSTEM 201119282-50 1
14 CABLE ASSEMBLY, SIGNAL DISTRIBUTION SYSTEM 201119282-70 1
15 ASSEMBLY, DIGITAL MULTIMETER 201119318-10 1
16 CABLE ASSEMBLY, DIGITAL MULTIMETER 201119320-10 1
17 ASSEMBLY, TTLIO 201119295-10 1
18 INSTRUMENT INTERFACE ADAPTER, TTLIO 201119297-10 1
19 INSTRUMENT INTERFACE ADAPTER, TTLIO 201119297-30 1
20 ASSEMBLY, ADVANCED VIDEO SYSTEM 201119300-10 1
21 ASSEMBLY, H009 INTERFACE 201119290-10 1
22 KIT, MODIFICATION LABELS FOR A31U18240-3 201643396 1
23 KIT, CONSUMABLES FOR A31U18240-3 201643397 1
A31U18240-4 UPGRADE KIT
24 ASSEMBLY, SIGNAL GENERATOR 201119230-10 1
25 ASSEMBLY, PHASE NOISE TEST SET 201119240-10 1
26 CABLE ASSEMBLY, A/C POWER 201119246-10 1
27 ASSEMBLY, FM SWITCH 201119243-10 1
28 ASSEMBLY, SPECTRUM ANALYZER 201119312-10 1
29 ASSEMBLY, REMOVABLE DRIVE 201119283-10 1
30 ATTENUATOR, 50 OHM 201119292-01 1
31 KIT, MODIFICATION LABELS 201643418 1
32 KIT, CONSUMABLES 201643419 1
SPARES
33 ASSEMBLY, RUBIDIUM REFERENCE (NSN: 6625-01-433-2710) 201119307-10 1
34 ASSEMBLY, BUS SIMULATOR (NSN: 6625-01-539-4401) S5106-WA73A-455 1
35 ASSEMBLY, RF GENERATOR #2 (NSN: 6625-01-434-1238) 1K8S7-1140A-SY12 1
36 ASSEMBLY, RF COUNTER (NSN: 6625-01-415-0140) 1K8S7-1231A 1
37 ASSEMBLY, POWER METER (NSN: 6625-01-529-6992) 58900-58542 1
38 ASSEMBLY, FORM-C RELAY MODULE (NSN: 6625-01-617-1374) 201119270-10 1
ASSEMBLIES/INSTRUMENTS not included with A31U18240-3 or A31U18240-4 UPGRADE KITS, or Spares
39 ASSEMBLY, COUNTER-TIMER/DIGITIZER 201119285-10 1
40 INSTRUMENT INTERFACE ADAPTER, COUNTER-TIMER/DIGITIZER 201119287-01 3
41 ASSEMBLY, HIGH SPEED DIGITAL WORD GENERATOR 201119238-10 3
42 CABLE SET, HIGH SPEED DIGITAL WORD GENERATOR 201119247-10 1
43 AIR IMPEDANCE MODULE 80-634JB-00-6T 2
6.5 Appendix E, LRU Assemblies List
Appendix E identifies the Line Replaceable Units (LRU) provided to SES as GFP under contract FA8505‐11‐D‐0002‐0006.
Table 1 lists the unserviceable LRUs requiring disposition. Table 2 lists the remaining serviceable LRUs to be used for regression testing during this effort.
Table 1. Unserviceable LRUs
Line Item Nomenclature PartNum Serial Number Condition
1 AAI-RADIO R/T, RT-868A/APX-76 119415 LEL044 Unserviceable
2 IFF TRANSPONDER RT-1063/APX-101 154000 247-124 Unserviceable
3 IFF TRANSPONDER RT-1063/APX-101 154000 279-006 Unserviceable
4 IFF TRANSPONDER RT-1063/APX-101 154000 WP2770 Unserviceable
5 AAI-RADIO R/T, RT-868C/APX-76 119415-4 CLT-650 Unserviceable
6 AAI-RADIO R/T, RT-868C/APX-76 119415-4 CCM700 Unserviceable
7 AAI-RADIO R/T, RT-868C/APX-76 119415-4 CYD181 Unserviceable
8 AAI-RADIO R/T, RT-868D/APX-76 119415-5 MQF130 Unserviceable
9 ACCELEROMETER INDICATOR 2094-2 0489 Unserviceable
10 ACCELEROMETER INDICATOR 2094-2 33714 Unserviceable
11 Electronic Control AMP, AM-6435/ASN-108 4004301-912 95121628 Unserviceable
12 MISCELLANEOUS RELAY PANEL 68A810720-1013 717530 Unserviceable
13 FLIGHT CONTROL COMPUTER, CP-1804/ASW-51 68B870226-1031 00294 Unserviceable
14 SIGNAL DATA CONVERTER, CV-3982/ASQ-195 A05A0248-4 0298 Unserviceable
Table 2. Serviceable LRUs
Line Item Nomenclature Condition PartNum Serial Number
1 AAI-RADIO R/T, RT-868A/APX-76 Serviceable 119415 CLT1287
2 IFF TRANSPONDER RT-1063/APX-101 Awaiting Test 154000 45413-30143
3 AAI-RADIO R/T, RT-868B/APX-76 Serviceable 119415-2 MKM015
4 AAI-RADIO R/T, RT-868D/APX-76 Serviceable 119415-5 MQF142
5 HUD GLASS, WFOV Serviceable 122120-9B 1233
6 CENTRAL COMPUTER, VHSIC Awaiting Test 134A600-87 01124
RADAR RCVR/EXCITER, R-2272/APG-70 (025)
MSIP
Awaiting Test 3173025-120 0371
DIG RAD SIG PROC, MX-10575/APG-70 (044)
MSIP
Serviceable 3173044-120 367
RADAR DATA PROC, MX-10576/APG-70 (082)
(F-15S)
Awaiting Test 3173082-125 0419
10 EMBEDDED GPS/INS (EGI) Serviceable 34200750-3042 1811
11 Electronic Control AMP, AM-6435/ASN-108 Awaiting Test 4004301-912 97041646
12 MISCELLANEOUS RELAY PANEL Serviceable 68A810720-1013 Not Serialized
13 MISCELLANEOUS RELAY PANEL Serviceable 68A810720-1013 92820138
14 Flight Control Computer (FCC) Serviceable 68B870226-1031 0288
15 UHF RT-1504/ARC-164 HQ II Serviceable 707650-801 AB0077
16 Multipurpose Color Display Serviceable 8001903-904 96030826
17 DIGITAL MAP SYSTEM Awaiting Test 8520305-911 97110058
18 SIGNAL DATA CONVERTER, CV-3982/ASQ-195 Serviceable A05A0247-4 0370
19 SIGNAL DATA CONVERTER, CV-3982/ASQ-195 Serviceable A05A0248-4 4094
20…
This is the start of the file's text. The full file is on GovTribe.