This document is a Performance Work Statement (PWS) for Analytical Laboratory Services in support of the United States Army Corps of Engineers (USACE) Omaha District's Formerly Used Defense Site (FUDS) environmental restoration program.
The PWS requires the contractor to provide technical and analytical services for chemical analysis, toxicity testing, microbiological testing, air testing, radiochemical testing, and asbestos testing of soil, sediment, sludge, groundwater, surface water, biota, air, wipe samples, and paint chips. The contractor must be certified under the DoD Environmental Laboratory Accreditation Program (ELAP) and meet specific quality control requirements. Analytical data must be provided in electronic data deliverables (EDDs) and as electronic PDF reports. The PWS describes sample handling, input to the Quality Assurance Project Plan, and other requirements. The laboratory must be responsive to USACE requests and resolve any data quality issues.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Questions and Answers 15 Apr 2024.pdf | ||
| Combined Synopsis Solicitation PANNWD-24-P-0000001834.pdf | ||
| Price Schedule.xlsx | XLSX spreadsheet | |
| Previous Experience Template.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PERFORMANCE WORK STATEMENT
FOR ANALYTICAL LABORATORY SERVICES
12 Feb 2024
1.0 PURPOSE
This scope of work is for analytical services support for the United States (U.S.) Army Corps of Engineers (USACE) Omaha District Geotechnical Engineering and Sciences Branch Chemistry Section (CENWO-ED-GS), in terms of chemical analysis, toxicity testing, microbiological testing including mold identification, air testing, radiochemical testing and asbestos testing. The matrices of interest for analysis are soil, sediment, sludge, groundwater, surface water, biota, air, wipe samples, solid phase microextraction devices (SPMEs), and paint chips. These samples are primarily to be collected from Department of Defense (DoD) Formerly Used Defense Site (FUDS) environmental restoration program. The Contract Laboratory shall provide support to the USACE Project Chemist in terms of providing necessary protocol information required by hazardous waste investigation and remediation programs conducted by, or on behalf of the USACE Omaha District.
2.0 GENERAL DESCRIPTION OF WORK REQUIRED UNDER THIS SCOPE OF
WORK
The Contractor, operating as an independent Contractor and not as an agent of the Government, shall provide all necessary personnel, equipment and materials required to obtain technically valid and legally defensible environmental data that will meet or exceed the analytical method criteria and the most current version of the DoD Quality Systems Manual (QSM) for Environmental Laboratories. The Contract Laboratory shall be able to provide all sample analyses using methods listed in the attached Table 1. For all FUDS projects, the Contract Laboratory shall submit data to the FUDSChem portal, as described in Section 6.1.
If services cannot be provided by the Contract Laboratory, services may be sub-contracted to another laboratory. The sub-contracted laboratory shall meet all of the requirements for the Primary Laboratory as specified in this agreement. For each call order, indicate which analytical services will be contracted out and identify the Sub-contract laboratory(s) that will be performing the analyses and provide all pertinent certifications. Should a subcontracted laboratory only be responsible for a particular analysis (such as asbestos) it will only be required to be certified for that particular analysis upon approval of the CENWO-ED-GS (see Section 4.0).
Calls will be issued under the blanket purchase agreements (BPAs). The USACE Contracting Officer (KO) or Contracting Officer’s Representative (COR) will provide the Contractor with any site-specific information upon issuance of each call. Information provided by the USACE on any site will be dependent on the current status of the site. Each call will define the performance requirements of the Contractor. Calls may require, but will not be limited to, any combination of the requirements stated in Section 3.0 below.
The description of work stated herein provides a general understanding of the Contractor functions to be performed; individual calls will contain the specific performance based requirements. Technical requirements described herein in no way limit the activities that may be required under the terms of this contract.
3.0 QUALITY CONTROL REQUIREMENTS
In addition to the requirements outlined in this Scope of Services, all work performed under this contract shall meet the quality control requirements in most recent version of the DoD QSM for
Environmental Laboratories (available at https://www.denix.osd.mil/ on the Environmental Data Quality Workgroup page) per DoD Instruction 4715.15 (October 2015). Project libraries should at a minimum conform to the latest version of the DoD QSM, unless specifically overridden by the USACE Project Chemist based on project specific data quality objectives (DQOs). The libraries used for analysis and data review shall be provided as part of the data package (Section 6.0).
4.0 LABORATORY CERTIFICATION
Laboratories performing analyses in support of this procurement must have an established and documented laboratory quality system that conforms to ISO/IEC 17025:2017 as implemented by the DoD Quality Systems Manual for Environmental Laboratories (latest version). Laboratories must possess any required state or host nation certification and/or be accredited for each applicable test method under the DoD ELAP or by a nationally recognized laboratory accreditation body (e.g. NELAP), compliant with ISO/IEC 17011:2017. The Contract laboratory must retain current certification under the DoD Environmental Laboratory Accreditation Program (ELAP). The DoD ELAP provides a means for laboratories to demonstrate conformance to the DoD QSM as authorized by DoD Instruction 4715.15. (More information concerning ELAP can also be found at https://www.denix.osd.mil/ under Environmental Data Quality Workgroup). If the Prime Laboratory subcontracts another laboratory which holds a specific accreditation, the Prime Laboratory shall specify the media, analyte, method, and certification for which the sub-contracted laboratory is responsible. All data from the subcontracted laboratory shall be provided to the Prime Laboratory to be delivered to USACE CENWO-ED-GS in accordance with the analytical deliverable package requirements (see Section 6.0).
Asbestos:
The Contract Laboratory must be accredited under the National Institute of Standards and Technology (NIST) “National Voluntary Laboratory Accreditation Program (NVLAP)” for bulk asbestos analysis. The laboratory shall be fully equipped and use analysts with demonstrated proficiency conducting polarized light microscopy (PLM) in accordance with 40 Code of Federal Regulations (CFR) 763, Subpart E, Appendix E.
Lead:
Laboratory shall participate in the United States Environmental Protection Agency (EPA) National Lead Laboratory Accreditation Program (NLLAP) accredited by either the American Association for Laboratory Accreditation (A2LA) or the American Industrial Hygiene Association (AIHA) and shall successfully participate in the Environmental Lead Proficiency Analytical Testing (ELPAT) program to perform sample analysis. Laboratories selected to perform blood lead analysis shall be Occupational Health and Safety Administration approved.
All Prime and subcontracted laboratories shall also identify any additional certifications they hold (State specific, etc.).
5.0 ANALYTICAL PROTOCOL
Analytical methods shown in Table 1 are from: Test Methods for Evaluating Solid Waste, USEPA SW-846, Third Edition, or other published methods such as Contract Laboratory Program (CLP), American Society for Testing and Materials (ASTM), 500/600 methods, EPA microbiological methods (http://www.epa.gov/ microbes/moldtech.htm) or other appropriate method manuals. The most recently published version of SW-846 will be used unless otherwise specified on a project specific basis. The laboratory should be aware of and comply with the project specific DQOs and applicable project requirements specified in task orders.
6.0 ANALYTICAL DATA PACKAGE
All data shall be submitted as electronic data deliverables (EDD) and shall have an electronic pdf “hard copy” report. Specific requirements for each are explained below. The electronic submissions, in the form of e-mail documents, files uploaded to FUDSChem, or CD’s are considered to be part of the analytical data package. A maximum of 28 days from sample receipt to delivery of the data package will be allowed, however, quicker turnaround of electronic submissions is favored.
6.1 Electronic Data Deliverables (EDDs)
All EDDs shall be submitted as Staged Electronic Data Deliverables (SEDDs) Stage 2a (5.2) which include all results, units, method, and instrument quality control data. If the laboratory has the capabilities to provide SEDD Stage 2b, 3 or 4, provide a separate table indicating costs associated with the deliverables. The most current version of SEDD shall be used in conjunction with the most current version of the DoD QSM valid values. For all FUDS projects, the SEDDs will be submitted to the FUDSChem portal, run through the compliance checker, and the laboratory must resolve any non-conformances (errors and warnings) with the project library and/or FUDSChem-required Valid Values or Submission Errors. The electronic library will be collectively developed between the USACE and the laboratory. The finalized library will be maintained by USACE, and a copy of the library used for each sample delivery group (SDG) shall be provided upon submittal of the electronic deliverables. Once the electronic deliverables and the “hard copy” pdf report have been uploaded to FUDSChem by the laboratory and project-specific USACE personnel have been notified via the FUDSChem upload portal that the SEDD and report are available, the USACE Project Chemist will review all data to ensure data completeness is appropriate for the validation process (See Section 6.3 for more specific details).
6.2 Electronic pdf “hard copy” report
The “hard copy” report format will follow the requirements set forth in Appendix A of the latest version of the DoD QSM v.5.0. Generally, there will be a cover sheet, table of contents, case narrative, analytical results, sample management records, quality assurance (QA)/quality control (QC) information and information for third-party review. The case narrative shall specifically address, but is not limited to: all abnormalities and deviations that may affect data quality of analytical results, any issue in the data package that potentially affects the usability of the data, identification of samples for which manual integration was necessary, numerical results were outside the limits of quantitation, and/or any other factor that could affect sample results (air bubbles or excessive headspace in volatile organic analysis (VOA) sample vials, presence of multiple phases, exceeds holding time, temperature and pH excursions, samples broken upon receipt, etc.) The final report should have a full complement of laboratory qualifiers as well as definitions for those qualifiers. Qualifiers should follow the most current version of the EPA National Functional Guidelines (www.epa.gov/superfund/programs/clp/guidance.htm) and the DoD QSM.
All hard copy reports must include all data to enable the Project Chemist to verify compliance with the latest version of the DoD QSM. An example of report elements required at a minimum for Methods 8260/8270 follows below:
Sample Identification #, Matrix, Prep and Test Method utilized, associated batch information
Case Narrative Chain of Custody, Sample Receipt Forms & Shipping documentation Telephone/email records associated with actions taken on quality issues
QC Verification for gas chromatography-mass spectrometry (GC/MS) (8260/8270) o Tuning
BFB ion abundance criteria and relative abundance, injection date and time (CLP Form V)
Breakdown Check (8270) Responses and tailing factors must be reported for DDT, benzidine, and pentachlorophenol.
o Initial calibrations (ICALs)
Date, time of analysis Show a minimum of 5 points used to determine ICAL Provide Response Factors (RF) and percent relative standard deviations (%RSD) for all analytes Indicate which samples were evaluated as system performance check compounds (SPCCs) and calibration check compounds (CCCs) Indicate method for calculation of calibration curve (linear, least square regression (with r value), non-linear regression (with r2 value & number of points used [6-second order, 7-third order]).
o Secondary Source Verification (ICV) Provide RF and %RSD for all analytes o Continuing Calibration Verification (CCV) Date, time and frequency of CCV analysis Provide RF and %RSD for all analytes Indicate which samples were evaluated as SPCCs and CCCs Present percent drift (%D) o Internal Standard Verification Report Area counts and retention times as well as the upper (200%) and lower (50%) limits and the 12-hour standard for the ICAL (CLP Form VIII).
Sample Results o Analysis results with proper units, reporting limit, method detection limit (MDL)
(limit of detection, limit of quantitation), surrogates, % recovery, and QC limits, percent moisture (soils), etc.
Qualification (flag) Definitions Third Party Document Review Items o Raw data (chromatograms, mass spec results) o Supporting documentation (run logs, sample prep logs, standard prep logs, etc.)
6.3 Submittal Approval Process:
Within 10 business days of receipt of EDDs and the hard copy report, if data is of sufficient quality and completeness, the USACE Project Chemist will submit to the Laboratory a Memorandum of Approval. EDDs shall still be provided via email, share site, or FUDSChem as appropriate as soon as available. The calendar for approval begins when the hard copy report arrives at the USACE CENWO-ED-GS office. If any discrepancies are found during the data review, the Project Chemist will notify the laboratory of the deficiencies to determine corrective measures.
7.0 OTHER REQUIREMENTS
7.1 Sample Handling and Custody Requirements:
The Contract laboratory shall have a procedure documenting proper sample handling and custody of samples. A Cooler Receipt Form shall be completed and e-mailed to the USACE Project Chemist on the day the samples are received or logged in at the laboratory to communicate the condition of the samples upon receipt. Any problems, such as warm samples (>4oC + 2 oC), broken bottles, missing samples, air bubbles in VOA vials, etc. will require immediate notification by laboratory personnel to the USACE Project Chemist prior to sample analysis.
7.2 Input to the Quality Assurance Project Plan (QAPP)
In order to obtain data of sufficient quality to satisfy data quality objectives for scientifically and legally defensible data, the FUDS environmental restoration program requires a QAPP. The QAPP describes organizational pathways of communication, field sampling efforts and laboratory efforts. The Contract laboratory’s input will be required for inclusion in the QAPP. Following the requirements of National Environmental Laboratory Accreditation Conference Chapter 5 and DoD QSM, the Contract laboratory must have a Quality Assurance or Quality System Manual (QA/QSM). For completion of the QAPP, specific areas addressed in the QA/QSM may need to be expanded upon. The Contract laboratory shall provide all additional information required by the USACE Project Chemist.
Project/Task Organization: A narrative or organizational chart showing key management and analytical personnel involved with the analysis as well as lines of communication among all project participants, USACE and the lab. Any key subcontractors will also need to be identified.
Analytical Method Requirements: The laboratory shall perform MDL studies on an annual basis, and make these studies available upon request. The MDL and MDL check samples shall be extraction/digestion method specific and instrument specific and shall include any clean-up methods routinely used. Laboratory standard operating procedures (SOPs) must also be available for attachment to the QAPP as an appendix. The SOP must describe the equipment and apparatus utilized and any specific performance requirements associated with it. Further, the SOP shall describe the calibration, calibration verification, method QC elements, their acceptance criteria and procedures taken for corrective actions.
Quality Control Requirements: Provide QA/QC checks done by the laboratory for both field QC samples, but also internal laboratory QC verification. The laboratory shall ensure that results from the laboratory internal quality control checks are reported with the associated batch of analytical data and that the sample results and the QC results can be easily correlated.
Corrective Action: A description of corrective actions taken when results appear unusual, questionable, or the limits of acceptability are exceeded. Provide the limits of acceptability and propose and describe how re-establishment of control is demonstrated.
Instrument /Equipment Testing, Inspection, and Maintenance Requirements: The laboratory will describe the implementation of the Preventative Maintenance systems and their schedule used to ensure the proper functioning of all laboratory and field apparatus.
Identify all equipment by the manufacturer’s name, model number, and accessories. The laboratory should be prepared to provide the types of inspections, documentation, and testing procedures, etc. required for all equipment.
Instrument Calibration and Frequency: For all instruments, the laboratory may have to describe the procedure used for calibrations and the frequency and types of calibration verification checks employed. The laboratory shall indicate how the records of calibrations are maintained and are traceable to the instrument and analyses.
8.0 RESPONSIVENESS
The laboratory shall identify the laboratory manager who has primary responsibility for project coordination and coordination of analyses. Especially when a short analytical turn-around time is required, the laboratory manager or designate should respond to USACE telephone or e-mail requests for information on short notice. Unresolved inquiries could result in re-performance of analyses in order to obtain data of known quality.
Table 1
Table 1 - Price List - Analytical Lab Services
Description
Methods Method of
Surveillance
Organics
Volatile Organics (VOC) current TCL list
5 ml purge 8260 100%
Inspection
25 ml purge 8260 100% Inspection unpreserved 7 day holding 8260
100% Inspection
VOC - Drinking Water 524.3
100% Inspection
VOC, PCE + TCE + 11-DCE + 12DCE +
VC
5 ml purge 8260 100%
Inspection
25 ml purge 8260 100%
Inspection unpreserved 7 day holding 8260 100%
Inspection
VOC, BTEX
5 ml purge 8260 100%
Inspection
25 ml purge 8260 100%
Inspection total in air NIOSH 1500
100%
Inspection
VOC, BTEX + MTBE
5 ml purge 8260
100% Inspection
25 ml purge 8260
100%
Inspection
1,4-Dioxane
25 ml purge 8260 SIM 100%
Inspection
UM-94
100%
Inspection
8270 SIM
Semi-Volatile Organics (BNA) TCL list
100% Inspection
100%
Inspection
Polynuclear Aromatic Hydrocarbons
(PAH)
100%
Inspection low level 8270 SIM 100%
Inspection
100%
Inspection Hydrocarbon Dissolved Gasses (Methand, Ethane, Ethene) RSK 175
Dissolved gas - CO2
RSK 175
Modified
100% Inspection
Toxic Organic Compunds includes individually certified clean 6-L Summa TO-14
100% Inspection
Toxic Organic Compunds includes individually certified clean 6-L Summa TO-15
100% Inspection
Toxic Organic Compunds (sorbent tubes) TO-17 100%
Inspection
Polyflourinated Compounds (PFAS) LC/MS/MS 1633 100%
Inspection
Polyflourinated Compounds (PFAS) LC/MS/MS
Direct Inject Screening(8421 or similar)
100% Inspection
Polyflourinated Compounds (PFAS) LC/MS/MS 537 Modified 100%
Inspection
Polyflourinated Compounds (PFAS) LC/MS/MS DoD QSM Table
B-15 100%
Inspection
Organochlorine Pesticides 8081 100%
Inspection
Chlorinated Herbicides 8151 100%
Inspection
Organophosphorus Pesticides GC/HPLC 8141 100%
Inspection
Polychlorinated biphenyls (PCBs) 8082 100%
Inspection
Dioxin/Furan
100%
Inspection
100%
Inspection low resolution 1613 100%
Inspection
Explosives preparation puck mill grinding 8330B
Inspection
Explosives
100% Inspection
Hydrazine, MMH, UDMH 8315 Modified 100%
Inspection
White phosphorus 7580 100%
Inspection
PETN/NG 8330B
100%
Inspection
Nitroguanidine 8330B Modified 100%
Inspection
Picramic Acid and Picric Acid 8330B Modified 100%
Inspection
Nitroaromatics, Nitroamines, Nitrate Esters, PETN, NG 8330 B
Perchlorate
LC/EMI/MS 331.0
100%
Inspection
IC/EMI/MS 332.0
100%
Inspection
HPLC/ESI/MS/MS 6850
100%
Inspection
IC/ESI/MS/MS 6860
100%
Inspection ion chromatography 314.0 100%
Inspection
Glycols: ethylene & propolyene glycol 8015 100%
Inspection Petroleum/ Underground Storage Tanks
Hydrocarbon Identification Method for Soil and Water (fingerprint) 8015
100% Inspection
TPH-GRO 8015
100%
Inspection
OA-1
100%
Inspection
TPH-DRO 8015
100%
Inspection
OA-2
100%
Inspection
TPH-RRO 8015
100%
Inspection Method for the Determination of Volatile Petroleum Hydrocarbons (VPH) Fractions MAVPH
Method for the Determination of Extractable Petroleum Hydrocarbons (EPH) Fractions MAEPH
Oil and Grease (Gravimetric) 413.1
Inspection
Oil and Grease (IR) 413.2 100%
Inspection
Oil and Grease 1664A
Metals Packages
MMRP Small Arms Range Constituents 100%
Inspection
Cu, Zn, Pb, SB 6010
Cu, Zn, Pb, SB 6020
RCRA Metals (8 total):
100%
Inspection
As, Ba, Cd, Cr, Pb, Se, Ag 6010
As, Ba, Cd, Cr, Pb, Se, Ag 6020
Hg by CV AA 7470/7471
Priority Pollutant Metals (13 total):
100%
Inspection
Ag, As, Be, Cd, Cr, Cu, Pb, Ni, Se, Sb, Tl, Zn 200.7/6010
Ag, As, Be, Cd, Cr, Cu, Pb, Ni, Se, Sb, Tl, Zn 200.8/6020
Hg by CV AA 245.2/7470
CLP TAL (24 total):
Al, Ba, Be, Ca, Cr, Co, Cu, Fe, Mg, Mn, Mo, Ni, K, Ag, Na, V, Zn, Sb, As, Cd, Pb, Se, Tl, Al, Ba, Be, Ca, Cr, Co, Cu, Fe, Mg, Mn, Mo, Ni, K, Ag, Na, V, Zn, Sb, As, Cd, Pb, Se, Tl, Hg by CV AA 7470/7471
Other Metals Analytical and Preparation Methods
Mercury, Cold Vapor AA 7470/7471
100% Inspection
Chromium, Hexavalent water 7196 A
100% Inspection soil 7196 A (3060A)
Inspection
Lead (Pb) - paint chips, wipes, air 200.8/6020
100% Inspection
Individual Metals (ICP)
100% Inspection
Individual Metals (ICP/MS)
100% Inspection
Leaching Proceedures
TCLP
100% Inspection
SPLP
100% Inspection
General Chemistry
Alkalinity (Carbonate)
310.1 or 310.2
Asbestos (PLM Test Method) 600/R-93/116
100% Inspection
Biochemical Oxygen Demand 405.1
100% Inspection
Chemical Oxygen Demand
410.1 or 410.4
100% Inspection
Chloride 325.2
100% Inspection
Chlorine – Residual 330.5
100% Inspection
Common Anions 300.1
100% Inspection
(Cl-, Br-, NO3-, NO2-, PO43-, SO4-)
SM 4110 B/C
Inspection
Conductivity 120.1
100% Inspection
Corrosivity to Steel 1110 A
100% Inspection
Cyanide - Amenable 335.1
100% Inspection
Cyanide - Reactive water (manual) 9010 / 9014
100% Inspection water (automated) 9010 / 9012
100% Inspection
Cyanide soil (manual) 9013 / 9014
100% Inspection soil (automated) 9013 / 9012
100% Inspection
Flashpoint 1010 A
ASTM D93
Inspection
Fluoride 340.2
100% Inspection
Hardness – Total
130.2 or 130.1
100% Inspection
Hardness - Ca and Mg
SM2340B
100% Inspection
Ignitability of solids
100% Inspection
Major Cations Na, (Na, K, Ca, and Mg (aq)
Na, K, Ca, Mg, Fe, Mn, and Al (soil)
100%
Moisture (%)
Mold Identification (www.epa.gov/nerlcwww/moldtech.htm)
Mold Technologies
Nitrogen – Ammonia 353.2
100% Inspection
Nitrogen – Nitrite 354.1
353.2
Inspection
Nitrogen - Nitrate and Nitrite 353.2
100% Inspection
Nitrogen - Total Kjeldahl 351.2
SM 4500
Inspection
Paint Filter / Liquid Release Test
100% Inspection pH water
100% Inspection soil
100% Inspection probe 150.1
100% Inspection
Phenolic Compounds
420.1 or 420.2
100% Inspection
Phosphate – Ortho 365.2
365.1
SM 4500 PE
Inspection
Phosphate – Total or Total Phosphorus 365.4
SM 4500 PF
Inspection
Salinity
SM2520B
100% Inspection
Solids – Dissolved 160.1
100% Inspection
Suspended
160.2 or SM
2540D 100%
Inspection
Total 160.3
100% Inspection
Settleable 160.5
100% Inspection
Soilids Volatile 160.4
100% Inspection
Specify Gravity
ASTM D854
SM 2710F
Inspection
Sulfate 375.2
SM 4500 SO4F
Inspection
Sulfide 376.2
9034 B
SM 4500S2E
Inspection
Sulfite 377.1
100% Inspection
Phosphorus – Total
SM 4500 PF
100% Inspection
Surfactant Test (MBAS) 425.1
SM 5540
Inspection
Temperature 170.1
100% Inspection
TOC
100% Inspection
TOC (soil) Lloyd Kahn
100% Inspection
TOX
100% Inspection
Turbidity 180.1
100% Inspection
Bromide 320.1
100% Inspection
Fats, Oils and Grease
100% Inspection
Volatile Fatty Acids 9056M
100% Inspection
AOX (Absorbable Organic Halides) 1653, 9020 or
100%
Inspection
Surfactant Test (MBAS) 425.1
100% Inspection
Acidity 305.2
100% Inspection
Radiochemistry
Gross Alpha 900.0
100% Inspection
Gross Beta 900.0
100% Inspection
Gamma Spectroscopy 901.1
100% Inspection
Radium-226 903.1
100% Inspection
Radium-228 904.0
100%
Chemical Warfare Methods
Mustard Breakdown Products (thioglycol, 1,4-dithiane, 1,4-oxathiane)
Lewisite Breakdown Products (CVAA and CVAO)
Compatibility Analyses
Solubility Observation
100% Inspection
Reactivity (air/water) Observation
100% Inspection
Density Observation
100% Inspection pH
100% Inspection
Flashpoint
Seta-flash (SW- 1010) or Pensky-
Martin
100% Inspection
Flammability Flame test
100% Inspection
Oxidizer Test strip
100% Inspection
Sulfide (Characteristic of Reactivity)
40 CFR 261.23
100% Inspection
Cyanide (Characteristic of Reactivity)
40 CFR 261.23
100% Inspection
Gross Halogen Beilstein
100% Inspection
PCB
Chlor-n-Oil
100% Inspection
Waste Blending Test Observation
100% Inspection
Cleanup Methods
Cleanup
100% Inspection
Florisil Cleanup
100% Inspection
Acid-Base Partition Cleanup
100% Inspection
Sulfur Cleanup
100% Inspection
Sulfuric Acid/Permanganate Cleanup
100% Inspection
Alumina Cleanup
100% Inspection
Alumina Column Cleanup and Separation of Petroleum Wastes 3611
Silica Gel Cleanup
100% Inspection
Gel-Permeation Cleanup
100%
Layered Silica Cleanup (neutral, basic, neutral, acidic, acidic) 1613
ENVI-carb included with
PFAS
100%
Inspection
Miscellaneous Items
Methanol kit for 5035 (1 Vial)
100% Inspection
NaHSO4 kit for low-level volatiles (3 Vial)
100%
Inspection
California Wet Extraction
CAL-WET CCR
Title 22 100%
Inspection
Asbestos
TEM
100% Inspection
Asbestos
PLM
100% Inspection
Acid Base Accounting SOBEK Method
100% Inspection
Microbiological
Heterotrophic Plate Count
SM9215D
100% Inspection
Algal Growth Potential
DM8111
100% Inspection
Algal species Composition:
Phytoplankton lab SOP 100%
Inspection
Algal Species Composition: Periphyton lab SOP
100% Inspection
Chlorophyll A
SM10200H
100% Inspection
E. Coli
SM9223B
100% Inspection
Fecal Coliform
SM9221
100% Inspection
Total Coliform
SM9223B
100% Inspection
Microcystin lab SOP
100% Inspection
In Vitro Bioaccessibility IVBA Assay for PB in soil 1340
Microarrays (Microbial Insights)
Dehalococodies, PCR
Functional Gene Analysis
Elutriate generation State Specific
100% Inspection
Elutriate generation USACE Manual
100% Inspection
Soil Process Parameters
Particle Size without hydrometer
ASTM D422
Particle Size with hydrometer
ASTM D422
100% Inspection
Grain Size
ASTM C136-
84A 100%
Inspection
Bulk Density
ASTM D2937
100% Inspection
Particle Density
ASTM D4253
100% Inspection
Permeability
ASTM D2432 /
D5084 100%
Inspection
Soil Permeability
MOSA 28-4.2
100% Inspection
Air Permeability
ASTM C204
100% Inspection pH
ASTM G51 /
D4972 100%
Eh
Humic Content
ASTM D2974
100% Inspection
Porosity
MOSA 18-2
100%
Transmissivity
Field Capacity
Cation Exchange Capacity
Halogen Content
Soil Nutrients (P, N, K)
Plasticity
Ash Fusion Temp.
Compaction
ASTM D698
100%
Density
Tension
Ash Content
ASTM D2974
100%
Bearing Capacity
Shrink-swell
Soil Oxidant Demand lab SOP
Benthic Oxygen Condition lab SOP
100% Inspection
Organic Content (sediment) lab SOP
100% Inspection
Environmental Microbiological Diagnostic Tools (EMBTs)
Microarray - petroleum
Microarray - chlorinated
Dehalococodies, PCR
Functional Gene Analysis
Stable Isotope Probing (SIP)
CSIA-Compound Specific Isotopic Analysis
Data Deliverables
Base Package -
EDD - SEDD 2A (current version) 100%
Level IV report - electronic pdf
CD with both EDD and Level IV report 100%
Inspection complaince checker - validation of all edds
Additional Items -
SEDD 2B (current version) 100%
Inspection
SEDD 3 (current version) 100%
Inspection
SEDD 4 (current version) 100%
Inspection
ERPIMS (current version) 100%
Inspection
FUDSCHEM (current version) 100%
Inspection
ERIS (current version) 100%