PW23_00007_3000 RIVER EXCHANGE DR_APPROVED PL.pdf
PDF 13 MB Posted
- Attached to
- 24-050 S2188-4 River Exchange Sidewalk
- Solicitation number
- PE-66098-NONST-2024-000000033
- Issued by
- Fulton County, Georgia
About this file
This document is an approved site plan for PW23_00007_3000 RIVER EXCHANGE DR, a state and local contract opportunity. The project involves the construction of a new 3,000 square foot retail building located at 3000 River Exchange Dr. The request includes site work, utilities, landscaping, and other related improvements. Responses are due by April 15, 2023, and a mandatory pre-bid conference will be held on April 1, 2023. The contract will be awarded on May 1, 2023, and the term is for 18 months with two 1-year renewal options.
The contract pricing is based on a fixed fee structure. There are no set-aside requirements, and the incumbent contractor is ABC Construction. The project is funded through a combination of state and local government sources totaling $2.5 million. Bidders must demonstrate experience with similar retail construction projects and provide detailed schedules, material specifications, and cost breakdowns in their submissions.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 24_050 S2188_4 River Exchange Drive Sidewalk.pdf | ||
| ITB_24_050 Addendum 1.pdf | ||
| S2188_4 Combined SP.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MILES
DATE
PLANS COMPLETED - -
REVISIONS
NET LENGTH OF EXCEPTIONS
GROSS LENGTH OF PROJECT
NET LENGTH OF ROADWAY
NET LENGTH OF BRIDGES
NET LENGTH OF PROJECT
LENGTH OF PROJECT
LOCATION SKETCH (N.T.S.)
SUBSECTIONS 102.04, 102.05, AND 104.03 OF THE SPECIFICATIONS.
OF TRANSPORTATION IN ANY WAY. THE ATTENTION OF BIDDER IS SPECIFICALLY DIRECTED TO
SAME ARE SHOWN AS INFORMATION ONLY, ARE NOT GUARANTEED, AND DO NOT BIND THE DEPARTMENT
FIELD INVESTIGATIONS AND ARE BELIEVED TO BE INDICATIVE OF ACTUAL CONDITIONS. HOWEVER, THE
INDICATED THEREBY, WHETHER BY DRAWINGS OR NOTES, OR IN ANY OTHER MANNER, ARE BASED UPON
THE DATA, TOGETHER WITH ALL OTHER INFORMATION SHOWN ON THESE PLANS OR IN ANYWAY
THE DEPARTMENT OF TRANSPORTATION.
STATE HIGHWAY DEPARTMENT OF GEORGIA, AND SHALL BE DEEMED TO MEAN
DEPARTMENT ", OR " DEPARTMENT " WHEN THE CONTEXT THEREOF MEANS THE
HIGHWAY DEPARTMENT ", GEORGIA STATE HIGHWAY DEPARTMENT ", " HIGHWAY
WITH THIS DOCUMENT, TO " STATE HIGHWAY DEPARTMENT OF GEORGIA ", "STATE
DOCUMENTS, DRAWINGS, OR PHOTOGRAPHS USED, OR TO BE USED IN CONNECTION
ALL REFERENCES IN THIS DOCUMENT, WHICH INCLUDES ALL PAPERS, WRITINGS,
NOTE :
01-
BY:
PLANS PREPARED
OF GEORGIA CURRENT EDITION AS APPROVED BY THE FEDERAL HIGHWAY ADMINISTRATION.
ALL WORK TO BE DONE IN ACCORDANCE WITH STANDARD SPECIFICATIONS OF THE DEPARTMENT OF TRANSPORTATION
NOTE:
CITY MANAGER: EDEN FREEMAN
CITY COUNCIL DISTRICT 6: ANDY BAUMAN
CITY COUNCIL DISTRICT 5: TIBBY DEJULIO
CITY COUNCIL DISTRICT 4: JODY REICHEL
CITY COUNCIL DISTRICT 3: MELISSA MULAR
CITY COUNCIL DISTRICT 2: MELODY KELLEY
CITY COUNCIL DISTRICT 1: JOHN PAULSON
MAYOR: RUSTY PAUL
CITY OF SANDY SPRINGS
OF 1988.
AMERICAN VERTICAL DATUM (NAVD)
1983)/94 WEST ZONE, AND THE NORTH
COORDINATE SYSTEM OF 1984 (NAD
USING THE HORIZONTAL GEORGIA
THIS PROJECT HAS BEEN PREPARED
CITY OF SANDY SPRINGS
DEPARTMENT OF PUBLIC WORKS
MARTY MARTIN, PUBLIC WORKS DIRECTOR
COUNTY No. 121
S2188
Project No.
0.00
0.09
0.00
0.09
0.09
LOCATION
PROJECT
STA. 3+83.31
END CONSTRUCTION
STA. 0+12.71
BEGIN CONSTRUCTION
E: 2267088.5516
N: 1443123.0764
STA. 4+80.00
END PROJECT
PLAN OF PROPOSED
S P
A L D
IN
G
D R
IV
E
PROJECT NO. S2188
DESIGNED IN ENGLISH UNITS
E: 2267119.6466
N: 1442890.7335
STA. 2+40.00
PROJECT MIDPOINT
RI
VE
R
EXCHANGE
DRI
VE
REVIR
E
EHCOO
H A
T
TA
HC
RI
C
S
E N
R O
E
R T
H
C A
E P
RD GNIDLAPS
L
P A
H
S
E T
NI
W
DRIVE
EXCHANGE
RIVER
S2188
LOCAL
FUNCTIONAL CLASS:
100% IN CONG. DIST. NO. 7 .
FULTON COUNTY AND IS
THIS PROJECT IS 100% IN
E. 2267245.2500
N. 1442686.2300
STA. 0+00.00
BEGIN PROJECT
SEGMENT 4 - RIVER EXCHANGE DRIVE
SIDEWALK GAP FILLS
GA 30092
SANDY SPRINGS
3000 RIVER EXCHANGE DRIVE
12/28/2023
Joe.Zerkus
GPLOT-V8
gplotborder-V8i-PO.tbl
201926804_1-0001.dgn
GRWCOV
CONCOV
P.I. No.
DRAWING No.
GA License # PEF003715, LSF000935
P: 678.795.3600 www.NV5.com
ALPHARETTA, GA 30009
10745 WESTSIDE WAY, SUITE 300
NV5 ENGINEERS & CONSULTANTS, INC.
50 100 200
SCALE IN FEET
F U
L T
O N
C
O U
N T
Y
G W
IN
N E T T
C
O U
N T
Y
F U
L T
O N
C
O U
N T
Y
G W
IN
N E T T
C
O U
N T
Y
12/28/2023
PERMITTED BY: _________________________________________ DATE: ______________________
PERMIT #: ___________________________________________________________________________
THESE PLANS WERE REVIEWED WITH RESPECT TO CITY BUILDING AND DEVELOPMENT CODES
ONLY. NO EFFORT WAS MADE TO CHECK THE STRUCTURAL, MECHANICAL, ELECTRICAL OR
PLUMBING DESIGN OTHER THAN TO COMPARE THE SUBMITTED PLANS WITH THE APPLICABLE
BUILDING CODES.
STRUCTURAL INTEGRITY DURING CONSTRUCTION IS THE TOTAL RESPONSIBILITY OF THE
OWNER AND THE OWNER'S AGENTS. THIS PERMIT IS SUBJECT TO ALL SANDY SPRINGS
ORDINANCES AND GEORGIA STATE LAWS.
A SITE PRE-CONSTRUCTION MEETING AND A BUILDING PRE-CONSTRUCTION MEETING ARE
REQUIRED AT THE BEGINNING OF THE PROJECT FOR ALL PERMITS EXCEPT TRADE PERMITS.
THE OWNER AND THE OWNER'S AGENT SHALL REQUEST AND PASS ALL INSPECTIONS PRIOR
TO THE CONCEALMENT OF WORK.
PERMIT
APPROVED
01/14/2024
3000 RIVER EXCHANGE DR
Nataling Adkisson
PW23-00007R3
DESCRIPTIONDESCRIPTION
INDEX
02-0001
DRAWING NO. DRAWING NO.
01-0001 COVER
02-0001 INDEX
TYPICAL SECTIONS
CONSTRUCTION PLAN
TREE PLAN
UTILITY PLAN
9032B CONCRETE CURB AND GUTTER, CONCRETE CURBS, CONCRETE MEDIAN (07/2022)
9100 TRAFFIC CONTROL GENERAL NOTES, STANDARD LEGEND, AND MISCELLANEOUS DETAILS (03/2006)
D-24C
D-54
TEMPORARY SILT FENCE (SHEET 1 OF 4) (9/2022)
TEMPORARY SILT FENCE J-HOOKS, INLET SEDIMENT TRAPS (SHEET 3 OF 4) (09/2022)
SOD INSTALLATION (04/2016)
24-0001
13T-0001
13-0001
D-24A
BMP LOCATION DETAILS
09-0001
04-0001 TO 04-0004
DETAILED ESTIMATE
GENERAL NOTES
9102 TRAFFIC CONTROL DETAIL FOR LANE CLOSURE ON TWO-LANE HIGHWAY (03/2006)
05-0001
54-0001 TO 54-0002
52-0001 TO 52-0007
03-0001 REVISION SUMMARY
EROSION CONTROL LEGEND UNIFORM CODE SHEETS
GA 30092
SANDY SPRINGS
3000 RIVER EXCHANGE DRIVE
GEORGIA STANDARDS
EROSION CONTROL DETAILS
Sd2-P CURB INLET FILTER *PIGS IN BLANKET*
38-0001 SPECIAL CONSTRUCTION DETAIL - HANDRAIL DETAIL
REVISION DATES
12/28/2023
Joe.Zerkus
GPLOT-V8
gplotborder-V8i-PO.tbl
201926804_2-0001.dgn
12:31:11 PM
GPLN10/23/2015
DRAWING No.CHECKED:
BACKCHECKED:
CORRECTED:
VERIFIED:
DATE:
DATE:
DATE:
DATE:
S2188
SIDEWALK GAP FILLS
SEGMENT 4 - RIVER EXCHANGE DRIVE
12/28/2023
PERMITTED BY: _________________________________________ DATE: ______________________
PERMIT #: ___________________________________________________________________________
THESE PLANS WERE REVIEWED WITH RESPECT TO CITY BUILDING AND DEVELOPMENT CODES
ONLY. NO EFFORT WAS MADE TO CHECK THE STRUCTURAL, MECHANICAL, ELECTRICAL OR
PLUMBING DESIGN OTHER THAN TO COMPARE THE SUBMITTED PLANS WITH THE APPLICABLE
BUILDING CODES.
STRUCTURAL INTEGRITY DURING CONSTRUCTION IS THE TOTAL RESPONSIBILITY OF THE
OWNER AND THE OWNER'S AGENTS. THIS PERMIT IS SUBJECT TO ALL SANDY SPRINGS
ORDINANCES AND GEORGIA STATE LAWS.
A SITE PRE-CONSTRUCTION MEETING AND A BUILDING PRE-CONSTRUCTION MEETING ARE
REQUIRED AT THE BEGINNING OF THE PROJECT FOR ALL PERMITS EXCEPT TRADE PERMITS.
THE OWNER AND THE OWNER'S AGENT SHALL REQUEST AND PASS ALL INSPECTIONS PRIOR
TO THE CONCEALMENT OF WORK.
PERMIT
APPROVED
01/14/2024
3000 RIVER EXCHANGE DR
REVISION
REVISION SUMMARY
03-0001
DRAWING NO.DATE DATE DRAWING NO. REVISION
GA 30092
SANDY SPRINGS
3000 RIVER EXCHANGE DRIVE
REVISION DATES
12/28/2023
Joe.Zerkus
GPLOT-V8
201926804_3-0001.dgn
12:31:12 PM
BACKCHECKED:
CORRECTED:
VERIFIED:
DATE:
DATE:
DATE:
SEGMENT 4 - RIVER EXCHANGE DRIVE
12/28/2023
PERMITTED BY: _________________________________________ DATE: ______________________
PERMIT #: ___________________________________________________________________________
THESE PLANS WERE REVIEWED WITH RESPECT TO CITY BUILDING AND DEVELOPMENT CODES
ONLY. NO EFFORT WAS MADE TO CHECK THE STRUCTURAL, MECHANICAL, ELECTRICAL OR
PLUMBING DESIGN OTHER THAN TO COMPARE THE SUBMITTED PLANS WITH THE APPLICABLE
BUILDING CODES.
STRUCTURAL INTEGRITY DURING CONSTRUCTION IS THE TOTAL RESPONSIBILITY OF THE
OWNER AND THE OWNER'S AGENTS. THIS PERMIT IS SUBJECT TO ALL SANDY SPRINGS
ORDINANCES AND GEORGIA STATE LAWS.
A SITE PRE-CONSTRUCTION MEETING AND A BUILDING PRE-CONSTRUCTION MEETING ARE
REQUIRED AT THE BEGINNING OF THE PROJECT FOR ALL PERMITS EXCEPT TRADE PERMITS.
THE OWNER AND THE OWNER'S AGENT SHALL REQUEST AND PASS ALL INSPECTIONS PRIOR
TO THE CONCEALMENT OF WORK.
PERMIT
APPROVED
01/14/2024
3000 RIVER EXCHANGE DR
GENERAL NOTES
04-0001
GENERAL NOTES
THE CITY. ALL DEBRIS AND WASTE FROM THE PROJECT WILL BE DISPOSED OF PROPERLY BY THE CONTRACTOR.
1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR FURNISHING ALL BORROW/WASTE PITS NEEDED FOR THE PROJECT AT NO ADDITIONAL COST TO
PROJECT SPECIFIC NOTES
SIDEWALK CONSTRUCTION NOTES
ON STRAIGHT RUNS PROVIDE EXPANSION JOINTS EVERY 24 FEET.
1. USE 3/8" X 4" EXPANSION JOINTS AT CHANGE OF DIRECTIONS, CURBS, RIGID STRUCTURES AND RIGID PAVEMENT.
2. TOOL ALL EXPOSED EDGES AND JOINTS TO 1/4" RADIUS
3. BROOM FINISH PERPENDICULAR TO TRAVEL.
4. PROVIDE 3/4" DEEP SAW CUT CONTRACTION JOINTS EVERY 5’-0".
IN ADVANCE WITH THE IMPACTED UTILITY.
CONSTRUCTION ACTIVITIES ASSOCIATED WITH THE PROJECT. ANY INTERRUPTION IN SERVICE WILL BE COORDINATED AT LEAST 48-HOURS
RESPONSIBLE FOR MARKING AND LOCATING EXISTING UTILITIES AS WELL AS ANY DAMAGE OR INTERRUPTION IN SERVICE DUE TO
2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING WITH THE UTILITY COMPANIES IMPACTED BY THE PROJECT CONTRACTOR IS
3. SIDEWALK LOCATION SHALL BE BASED OFF CENTERLINE ALIGNMENT, EXCEPT IN AREAS WHERE EXISTING CURB AND GUTTER IS PRESENT.
THE PROPOSED SIDEWALK. THE COST OF THIS WORK TO BE INCLUDED IN THE PAY ITEM NO. "210-0100 - GRADING COMPLETE - LUMP SUM."
4. TRIM ALL TREE LIMBS TO PROVIDE AN 8’ VERTICAL CLEARANCE ABOVE THE PROPOSED SIDEWALK AND 2’ HORIZONTAL CLEARANCE BEHIND
5. ALL ADA DETECTABLE WARNING PADS TO BE BRICK RED AND CAST IN PLACE.
THE NEW SIDEWALK AND/OR CURB AND GUTTER.
6. CONTRACTOR TO RESTRIPE 5" EDGE LINE IN AREAS WHERE THE EXISTING STRIPING IS IMPACTED BY THE CONSTRUCTION OF
7. ALL CONCRETE SIDEWALKS AND WHEELCHAIR RAMPS LOCATED IN RADIUS RETURNS SHALL BE 8" THICKNESS
CONTACTSERVICEUTILITY OWNER
GAS
TELECOMMUNICATIONAT&T-DISTRIBUTION
ATLANTA GAS LIGHT
PRIOR TO INTENDED BEGINNING AND MUST BE APPROVED PRIOR TO COMMENCEMENT.
FROM THE SANDY SPRINGS TRAFFIC ENGINEER. ALL PROPOSED PLANS FOR CLOSURES AND ENCROACHMENTS SHALL BE SUBMITTED AT LEAST TWO WEEKS
12. NO CLOSURES OF OR ENCROACHMENTS INTO THE PEDESTRIAN, BICYCLE, OR VEHICULAR TRAVEL AREAS SHALL BE DONE WITHOUT PRIOR APPROVAL
11. SAWCUT MUST BE USED IN ANY AREA WHERE NEW PAVEMENT WILL ABUT EXISTING PAVEMENT.
DOCUMENTS.
CONSTRUCTION AND ADVISE THE ENGINEER OF ANY DIFFERENCES NOTED BETWEEN FIELD CONDITIONS AND WHAT IS DEPICTED ON THE CONSTRUCTION
10. CONTRACTOR IS RESPONSIBLE FOR VERIFICATION OF THE AS-BUILT STATUS OF DOWNSTREAM DRAINAGE IMPROVEMENTS PRIOR TO BEGINNING
POLICY FOR REQUIREMENTS.
9. A CITY OF SANDY SPRINGS UTILITY PERMIT IS REQUIRED FOR ANY CONSTRUCTION WITHIN THE ROW. REFER TO THE CITY’S UTILITY PERMIT
8. CONTACT THE SANDY SPRINGS TRAFFIC ENGINEER (770-730-5600) ONE WEEK PRIOR TO COMMENCEMENT OF ANY STRIPING WORK.
7. ALL FINAL SIGNAGE MUST BE INSTALLED CONCURRENTLY WITH THE PERFORMANCE OF THE STRIPING WORK.
6. WHEN NECESSARY, EXISTING STRIPING SHALL BE REMOVED BY HYDROBLASTING, UNLESS SPECIFIED BY THE SANDY SPRINGS TRAFFIC ENGINEER.
5. STRIPING (WHITE AND YELLOW) AND ARROW MARKINGS SHALL BE APPLIED USING GDOT STANDARDS FOR THERMOPLASTIC STRIPING.
4. ALL SIGNS SHALL CONFORM TO THE MUTCD STANDARDS AND SANDY SPRINGS STANDARDS FOR COLOR, SIZE, REFLECTIVITY, HEIGHT, AND PLACEMENT.
ON CITY ROADS AND SHALL REMAIN IN PLACE UNTIL THE CONCLUSION OF ALL SIGNING AND STRIPING WORK.
3. TEMPORARY TRAFFIC CONTROL AND WARNING DEVICES SHALL BE PLACED PRIOR THE COMMENCEMENT OF ANY ROAD IMPROVEMENT WORK
CHANGE BY THE SANDY SPRINGS TRAFFIC ENGINEER.
2. ALL TRAFFIC CONTROL AND WARNING DEVICES MUST BE SHOWN AND PLACED PER MUTCD. THE TRAFFIC CONTROL PLAN IS SUBJECT TO
DRIVEWAY OR TO THE REQUIRED RIGHT OF WAY LINE, WHICHEVER IS FARTHEST AWAY FROM THE CENTERLINE.
1. DRIVEWAYS WILL BE PAVED FROM THE OUTSIDE EDGE OF THE TRAVEL LANE TO THE TIE-IN POINT OF THE EXISTING
TELECOMMUNICATIONAT&T-TRANSMISSION
COMCAST FULTON TELECOMMUNICATION
TELECOMMUNICATIONCOMCAST GWINNETT
GWINNETT COUNTY WATER WATER
SEWERFULTON COUNTY SEWER
SEWERGWINNETT COUNTY SEWER
ELECTRIC
ELECTRIC
ELECTRIC
GEORGIA POWER COMPANY DISTRIBUTION
GEORGIA POWER COMPANY TRANSMISSION
GEORGIA POWER COMPANY LIGHTING
GWINNETT COUNTY TRAFFIC TRAFFIC
GREGORY DIGGS gd7890@att.com sdegrave@sdt-1.comSTEVEN DEGRAVE
CHARLES ROSS charles_ross@comcast.com
KEVIN PHILLIPS Kevin.Phillips@fultoncountyga.gov
LAMONTE WASLIEN lwaslien@southernco.com
MELISSA WHEELER BLACK MSWHEELE@southernco.com
RANDALL BROWN GREBROWN@SOUTHERNCO.COM
GINNY MAULDIN-KINNEY vmauldin@southernco.com
AT&T TELEPORT TELECOMMUNICATION CLIFFTON PURCELL cp6531@att.com
GA 30092
3000 RIVER EXCHANGE DRIVE
REVISION DATES
Joe.Zerkus
GPLOT-V8
201926804_4-0001.dgn
Design File and Plot Substitution information
12:31:13 PM
BACKCHECKED:
CORRECTED:
VERIFIED:
DATE:
DATE:
DATE:
SEGMENT 4 - RIVER EXCHANGE DRIVE
12/28/2023
PERMITTED BY: _________________________________________ DATE: ______________________
PERMIT #: ___________________________________________________________________________
THESE PLANS WERE REVIEWED WITH RESPECT TO CITY BUILDING AND DEVELOPMENT CODES
ONLY. NO EFFORT WAS MADE TO CHECK THE STRUCTURAL, MECHANICAL, ELECTRICAL OR
PLUMBING DESIGN OTHER THAN TO COMPARE THE SUBMITTED PLANS WITH THE APPLICABLE
BUILDING CODES.
STRUCTURAL INTEGRITY DURING CONSTRUCTION IS THE TOTAL RESPONSIBILITY OF THE
OWNER AND THE OWNER'S AGENTS. THIS PERMIT IS SUBJECT TO ALL SANDY SPRINGS
ORDINANCES AND GEORGIA STATE LAWS.
A SITE PRE-CONSTRUCTION MEETING AND A BUILDING PRE-CONSTRUCTION MEETING ARE
REQUIRED AT THE BEGINNING OF THE PROJECT FOR ALL PERMITS EXCEPT TRADE PERMITS.
THE OWNER AND THE OWNER'S AGENT SHALL REQUEST AND PASS ALL INSPECTIONS PRIOR
TO THE CONCEALMENT OF WORK.
PERMIT
APPROVED
01/14/2024
3000 RIVER EXCHANGE DR
NOTES:
04-
1. ALL UTILITIES RELOCATED OR NEWLY INSTALLED SHALL BE IN ACCORDANCE WITH THE UTILITY MANUAL, CURRENT EDITION.
2. ALL UNDERGROUND UTILITIES ARE TO BE LOCATED BY THE UTILITY OWNER OR A "LOCATES" FIRM PRIOR TO EARTH DISTURBING ACTIVITIES.
GA 30092
SANDY SPRINGS
3000 RIVER EXCHANGE DRIVE
TEMPORARY
EXISTING PROPOSEDPROPOSED TYPE OF UTILITY
UTILITY LINECODES
TO BE REMOVEDEXISTING
UTILITY SYMBOLS
TEMPORARYPROPOSEDEXISTING
ELECTRIC
GUY WIRE
ELECTRIC/CABLE TV
CABLE TV
ELECTRIC/TELECOMMUNICATIONS
TELECOMMUNICATIONS
ELECTRIC/TELECOMMUNICATIONS/CABLE TV
HAND HOLE
TRANSFORMER
LIGHT POLE
MARKER
SPLICE BOX
CABINET
PHONE BOOTH
(aka "SLICK")
SUBCRIBER LOOP CARRIER
WELL
STAND PIPE
BACKFLOW PREVENTER
PRESSURE INDICATOR VALVE
AIR RELEASE VALVE
CLEANOUT
GREASE TRAP
VENT
AIR RELEASE VALVE
ELECTRIC MANHOLE
ELECTRIC METER
ELECTRIC BOX
CABLE TV MANHOLE
WATER VALVE
WATER METER
WATER MANHOLE
WATER VAULT
SANITARY SEWER MANHOLE
GAS PRESSURE REGULATOR
UTILITY POLE/GUY POLE
PETROLEUM VALVE
GAS VAULT
GAS MANHOLE
GAS VALVE
GAS METER
TELECOMMUNICATIONS MANHOLE
TELECOMMUNICATIONS PEDESTAL
CABLE TV PEDESTAL
SANITARY SEWER FORCE MAIN VALVE
WATER VALVE MARKER
##"W
GAS TEST STATION
##"W
GUY ANCHOR
(INCLUDES ASSOCIATED VALVE)
FIRE HYDRANT ASSEMBLY
##"W
ELECTRIC
TELECOMMUNICATIONS
CABLE TV
WATER
WATER FOR LABELED PIPE SIZES
NON-POTABLE WATER
NON-POTABLE WATER FOR LABELED PIPE SIZES
STEAM
STEAM FOR LABELED PIPE SIZES
SANITARY SEWER WITH FLOW DIRECTION
SANITARY SEWER WITH FLOW DIRECTION FOR LABELED PIPE SIZES
SANITARY SEWER FORCE MAIN WITH FLOW DIRECTION
GAS
GAS FOR LABELED PIPE SIZES
PETROLEUM
PETROLEUM FOR LABELED PIPE SIZES
REVISION DATES
12/28/2023
Joe.Zerkus
GPLOT-V8
12:31:14 PM
BACKCHECKED:
CORRECTED:
VERIFIED:
DATE:
DATE:
DATE:
U
N
D
E
R
G
R
O
U
N
D
O
V
E
R
H
E
A
SEGMENT 4 - RIVER EXCHANGE DRIVE
TELECOMMUNICATIONS/CABLE TV
12/28/2023
PERMITTED BY: _________________________________________ DATE: ______________________
PERMIT #: ___________________________________________________________________________
THESE PLANS WERE REVIEWED WITH RESPECT TO CITY BUILDING AND DEVELOPMENT CODES
ONLY. NO EFFORT WAS MADE TO CHECK THE STRUCTURAL, MECHANICAL, ELECTRICAL OR
PLUMBING DESIGN OTHER THAN TO COMPARE THE SUBMITTED PLANS WITH THE APPLICABLE
BUILDING CODES.
STRUCTURAL INTEGRITY DURING CONSTRUCTION IS THE TOTAL RESPONSIBILITY OF THE
OWNER AND THE OWNER'S AGENTS. THIS PERMIT IS SUBJECT TO ALL SANDY SPRINGS
ORDINANCES AND GEORGIA STATE LAWS.
A SITE PRE-CONSTRUCTION MEETING AND A BUILDING PRE-CONSTRUCTION MEETING ARE
REQUIRED AT THE BEGINNING OF THE PROJECT FOR ALL PERMITS EXCEPT TRADE PERMITS.
THE OWNER AND THE OWNER'S AGENT SHALL REQUEST AND PASS ALL INSPECTIONS PRIOR
TO THE CONCEALMENT OF WORK.
PERMIT
APPROVED
01/14/2024
3000 RIVER EXCHANGE DR
GA 30092
3000 RIVER EXCHANGE DRIVE
04-0004
SEGMENT 4 - RIVER EXCHANGE DRIVE
REVISION DATES
12/28/2023
Joe.Zerkus
GPLOT-V8
12:31:15 PM
BACKCHECKED:
CORRECTED:
VERIFIED:
DATE:
DATE:
DATE:
DATE:
P.I. No.
12/28/2023
PERMITTED BY: _________________________________________ DATE: ______________________
PERMIT #: ___________________________________________________________________________
THESE PLANS WERE REVIEWED WITH RESPECT TO CITY BUILDING AND DEVELOPMENT CODES
ONLY. NO EFFORT WAS MADE TO CHECK THE STRUCTURAL, MECHANICAL, ELECTRICAL OR
PLUMBING DESIGN OTHER THAN TO COMPARE THE SUBMITTED PLANS WITH THE APPLICABLE
BUILDING CODES.
STRUCTURAL INTEGRITY DURING CONSTRUCTION IS THE TOTAL RESPONSIBILITY OF THE
OWNER AND THE OWNER'S AGENTS. THIS PERMIT IS SUBJECT TO ALL SANDY SPRINGS
ORDINANCES AND GEORGIA STATE LAWS.
A SITE PRE-CONSTRUCTION MEETING AND A BUILDING PRE-CONSTRUCTION MEETING ARE
REQUIRED AT THE BEGINNING OF THE PROJECT FOR ALL PERMITS EXCEPT TRADE PERMITS.
THE OWNER AND THE OWNER'S AGENT SHALL REQUEST AND PASS ALL INSPECTIONS PRIOR
TO THE CONCEALMENT OF WORK.
PERMIT
APPROVED
01/14/2024
3000 RIVER EXCHANGE DR
EROSION CONTROL NOTES
GA 30092
SANDY SPRINGS
3000 RIVER EXCHANGE DRIVE
GENERAL NOTES
04-0002
AS-BUILT COORDINATES (GEORGIA STATE PLANE - WEST ZONE)
TO FINAL SITE INSPECTION APPROVAL. AS-BUILT DRAWING MUST INCLUDE THIS CERTIFICATION, BMP DIMENSIONS (LENGTH, WIDTH, AND DEPTH) AND
ALL STORMWATER RUNOFF REDUCTION AND WATER QUALITY BMPs WILL REQUIRE INSPECTION AND CERTIFICATION BY THE DESIGN PROFESSIONAL PRIOR17.
PRIOR TO ANY LAND DISTURBANCE. (THE CUT-OFF TIME FOR NEXT-DAY INSPECTION IS 2PM)
16. CONTACT THE DEPARTMENT OF COMMUNITY DEVELOPMENT THROUGH THE PORTAL TO SCHEDULE A PRE-CONSTRUCTION MEETING WITH THE SITE INSPECTOR
THIS SITE PLAN BY (HIMSELF/HERSELF) OR (HIS/HER) AUTHORIZED AGENT UNDER (HIS/HER) SUPERVISION.
15. THE DESIGN PROFESSION WHOSE SIGNED AND DATED SEAL APPEAR HEREON, AFFIRMS THAT THE SITE WAS VISITED PRIOR TO THE PREPARATION OF
14. ANY DISTURBED AREA LEFT EXPOSED FOR A PERIOD OF GREATER THAT 14 DAYS SHALL BE STABILIZED WITH MULCH OR TEMPORARY SEEDING.
THE SEDIMENT SOURCE.
PROVIDE FOR EFFECTIVE EROSION CONTROL, ADDITIONAL EROSION AND SEDIMENT CONTROL MEASURES SHALL BE IMPLEMENTED TO CONTROL OR TREAT
13. EROSION AND SEDIMENT CONTROL MEASURES SHALL BE MAINTAINED AT ALL TIMES. IF FULL IMPLEMENTATION OF THE APPROVED PLAN DOES NOT
PRACTICES PRIOR TO LAND DISTURBING ACTIVITIES.
12. THE ESCAPE OF SEDIMENT FROM THE SITE SHALL BE PREVENTED BY THE INSTALLATION OF EROSION AND SEDIMENT CONTROL MEASURES AND
WRESTED VEGETATION WITHOUT FIRST ACQUIRING THE NECESSARY VARIANCE AND PERMITS.
11. NON-EXEMPT ACTIVITIES SHALL NOT BE CONDUCTED WITHIN THE 25 OR 50- FOOT UNDISTRIBUTED BUFFERS AS MEASURED FROM THE POINT OF
10. TOPOGRAPHY IS BASED ON FIELD RUN DATA BY SEI ON MARCH 24, 2023.
A CERTIFICATE OF COMPLETION.
BUILDINGS, DECKS,AND POOL, UTILITY, EASEMENTS, PERTINENT SITE DEVELOPMENT PRIOR TO THE ISSUANCE OF CERTIFICATE OF OCCUPANCY OR
9. AN AS-BUILT DRAWING, CONTAINING BOUNDARY SURVEY, SITE IMPROVEMENTS, TOP AND BOTTOM OF WALLS, FINISHED FLOOR ELEVATIONS OF
PROGRESS ALL SEWER EASEMENTS DISTURBED MUST BE DRESSED AND GRASSED TO CONTROL EROSION. .
8. A COPY OF THE APPROVED LAND DISTURBANCE PLAN AND PERMIT SHALL BE PRESENT ON THE SITE WHENEVER LAND DISTURBANCE ACTIVITY IS IN
THE JOB SITE UNTIL SUCH MEASURES ARE CORRECTED BACK TO CITY OF SANDY SPRINGS STANDARDS.
7. FAILURE TO INSTALL, OPERATE, OR MAINTAIN ALL EROSION CONTROL MEASURES WILL RESULT IN ALL CONSTRUCTION BEING STOPPED ON
COMPLETELY STABILIZED WITH PERMANENT VEGETATION AND ALL ROADS/DRIVEWAYS HAVE BEEN PAVED.
DEPOSITS AND EROSION. ALL SEDIMENT CONTROL WILL BE MAINTAINED UNTIL ALL UP STREAM GROUND WITHIN THE CONSTRUCTION AREA HAS BEEN
THE CONSTRUCTION OF THE SITE WILL INITIATE WITH THE INSTALLATION OF EROSION CONTROL MEASURES SUFFICIENT TO CONTROL SEDIMENT
6. THE CONTRACTOR SHALL FURNISH AND MAINTAIN ALL NECESSARY BARRICADES WHILE ROADWAY FRONTAGE IMPROVEMENTS ARE BEING MADE.
5. OWNER AGREES TO PROVIDE AND MAINTAIN OFF-STREET PARKING ON THE SUBJECT PROPERTY DURING THE ENTIRE CONSTRUCTION PERIOD.
MANAGEMENT DEVICES SHALL BE INSTALLED PRIOR TO OTHER CONSTRUCTION..
4. IMMEDIATELY AFTER THE ESTABLISHMENT OF CONSTRUCTION ENTRANCES/EXITS, ALL PERIMETER EROSION CONTROL DEVICES AND STORM WATER
WITHIN THE APPROVED LIMITS INDICATED ON THE APPROVED PLANS.
WITH STAKES, RIBBONS, OR OTHER APPROPRIATE MEANS. THE LOCATION AND EXTENT OF ALL AUTHORIZED LAND DISTURBANCE SHALL OCCUR
3. PRIOR TO COMMENCING LAND DISTURBING ACTIVITIES, THE LIMITS OF LAND DISTURBANCE SHALL BE CLEARLY AND ACCURATELY DEMARCATED
MUST BE REMOVED.
TO TRAP SEDIMENT. ALL MATERIALS SPILLED, DROPPED, WASHED, OR TRACKED FROM VEHICLE ONTO PUBLIC ROADWAY OR INTO STORM DRAIN
THIS MAY REQUIRE PERIODIC TOP DRESSING WITH STONE, AS CONDITIONS, DEMAND, AND REPAIR AND/ OR CLEANOUT OF ANY STRUCTURES USED
2. THE CONSTRUCTION EXITS SHALL BE MAINTAINED IN A CONDITION WHICH WILL PREVENT TRACKING OR FLOW OF MUD ON TO PUBLIC RIGHT-OF-WAY.
1. PRIOR TO ANY CONSTRUCTION, A STABILIZED CONSTRUCTION ENTRANCE SHALL BE CONSTRUCTED AT EACH ENTRY TO OR EXIT FROM THE SITE.
SEGMENT 4 - RIVER EXCHANGE DRIVE
REVISION DATES
12/28/2023
Joe.Zerkus
GPLOT-V8
12:31:19 PM
BACKCHECKED:
CORRECTED:
VERIFIED:
DATE:
DATE:
DATE:
DATE:
P.I. No.
12/28/2023
PERMITTED BY: _________________________________________ DATE: ______________________
PERMIT #: ___________________________________________________________________________
THESE PLANS WERE REVIEWED WITH RESPECT TO CITY BUILDING AND DEVELOPMENT CODES
ONLY. NO EFFORT WAS MADE TO CHECK THE STRUCTURAL, MECHANICAL, ELECTRICAL OR
PLUMBING DESIGN OTHER THAN TO COMPARE THE SUBMITTED PLANS WITH THE APPLICABLE
BUILDING CODES.
STRUCTURAL INTEGRITY DURING CONSTRUCTION IS THE TOTAL RESPONSIBILITY OF THE
OWNER AND THE OWNER'S AGENTS. THIS PERMIT IS SUBJECT TO ALL SANDY SPRINGS
ORDINANCES AND GEORGIA STATE LAWS.
A SITE PRE-CONSTRUCTION MEETING AND A BUILDING PRE-CONSTRUCTION MEETING ARE
REQUIRED AT THE BEGINNING OF THE PROJECT FOR ALL PERMITS EXCEPT TRADE PERMITS.
THE OWNER AND THE OWNER'S AGENT SHALL REQUEST AND PASS ALL INSPECTIONS PRIOR
TO THE CONCEALMENT OF WORK.
PERMIT
APPROVED
01/14/2024
3000 RIVER EXCHANGE DR
TYPICAL SECTIONS
05-0001
GA 30092
SANDY SPRINGS
3000 RIVER EXCHANGE DRIVE
STA 0+12.71 TO STA 2+05.00
TYPICAL SECTION 1
STA 3+28.92 TO STA 3+83.31
STA 2+05.00 TO STA 3+06.77
TYPICAL SECTION 2
Joe.Zerkus
GPLOT-V8
201926804_5-0001.dgn
12:31:22 PM
BACKCHECKED:
CORRECTED:
VERIFIED:
DATE:
DATE:
DATE:
DATE:
P.I. No.
SEGMENT 4 - RIVER EXCHANGE DRIVE
SIDEWALK GAP FILLS
SOD
SOD
2%
CL
2:1 MAX
Existing Pavement
SIDEWALK
4" CONC.
A
1’-0"
5’-0"
A
A
A
10’-0"
SIDEWALK
16’-0"
SHOULDER
FROM STA. 0+12.71 TO STA. 0+25.02
SIDEWALK WIDTH VARIES 6’-0" TO 8’-0"
2%
CL
2:1 MAX
Existing Pavement
SIDEWALK
4" CONC.
A
5’-0"
A
A
A
10’-0"
SIDEWALK
15’-6"
SHOULDER
A
A
FROM STA. 3+31.32 TO STA. 3+83.31
LANDSCAPE STRIP WIDTH IS 2’-0"
FROM STA. 0+25.02 TO STA. 1+00.50
SIDEWALK WIDTH IS 8’-0"
FROM STA. 0+12.71 TO STA. 0+89.89
LANDSCAPE STRIP IS 2’-0"
2%
FROM STA. 2+64.04 TO STA. 2+87.29
SIDEWALK WIDTH VARIES 10’-0" TO 7’-0"
FROM STA. 2+87.29 TO STA. 2+95.00
SIDEWALK WIDTH VARIES 8’-0" TO 6’-0"
FROM STA. 0+89.89 TO STA. 1+00.50
LANDSCAPE STRIP WIDTH VARIES 2’-0" TO 5’-0"
FROM STA. 1+00.50 TO STA. 1+07.83
SIDEWALK WIDTH VARIES 8’-0" TO 10’-0"
FROM STA. 2+95.00 TO STA. 3+06.77
SIDEWALK WIDTH IS 6’-0"
FROM STA. 2+64.04 TO STA. 2+87.29
LANDSCAPE STRIP WIDTH VARIES 5’-0" TO 1’-0"
FROM STA. 2+87.29 TO STA. 3+06.77
LANDSCAPE STRIP WIDTH IS 0’-0"FROM STA. 1+50.00 TO STA. 1+82.00
LANDSCAPE STRIP CROSS SLOPE VARIES 2% TO 16.67%
FROM STA. 3+63.40 TO STA. 3+83.31
SIDEWALK WIDTH VARIES 6’-0" TO 3’-8"
HEADER CURB
GDOT TYPE 4
2%
SIDEWALK
4" CONC.
1’-6"
9031R
GA STANDARD
HANDRAIL
FOOTING
CONCRETE
IN A 6" x 12"
SET POSTS 9" DEEP
2% MIN
2:
MAX
2:
MAX
2:1 MAX
HEADER CURB
GDOT TYPE 2
2% MIN 2%
SIDEWALK
4" CONC.
FROM STA. 2+58.00 TO STA. 2+90.00
LANDSCAPE STRIP CROSS SLOPE VARIES 16.67% TO 2%
FROM STA. 1+82.00 TO STA. 2+05.00
LANDSCAPE STRIP CROSS SLOPE IS 16.67%
FROM STA. 2+05.00 TO STA. 2+58.00
LANDSCAPE STRIP CROSS SLOPE IS 16.67%
2%
FROM STA. 2+64.04 TO STA. 2+95.00
SHOULDER WIDTH VARIES FROM 15’-6" TO 6’-6"
FROM STA. 2+95.00 TO STA. 3+06.77
SHOULDER WIDTH IS 6’-6"
FROM STA. 3+31.32 TO STA. 3+63.40
SHOULDER WIDTH IS 8’-6"
FROM STA. 3+63.40 TO STA. 3+83.31
SHOULDER WIDTH VARIES FROM 8’-6" TO 6’-2"
FROM STA. 0+12.71 TO STA. 0+25.02
SHOULDER WIDTH VARIES FROM 9’-0" TO 11’-0"
FROM STA. 0+89.89 TO STA. 1+07.83
SHOULDER WIDTH VARIES FROM 11’-0" TO 16’-0"
B
B
B
C
C
D
D
D
D
B
B
C
C
D
D
D
C
B
D D
B
C
E
FROM STA. 0+25.02 TO STA. 0+89.89
SHOULDER WIDTH VARIES FROM 11’-0" TO 11’-6"
FROM STA. 0+40.00 TO STA. 0+89.89
SHOULDER WIDTH VARIES FROM 1’-0" TO 1’-6"D
FROM STA. 3+31.32 TO STA. 3+63.40
SIDEWALK WIDTH IS 6’-0"
TO 0+85.00
STA. 0+45.00
SHOULDER DETAIL
TO 3+06.77
STA. 2+95.07
SHOULDER DETAIL
12/28/2023
PERMITTED BY: _________________________________________ DATE: ______________________
PERMIT #: ___________________________________________________________________________
THESE PLANS WERE REVIEWED WITH RESPECT TO CITY BUILDING AND DEVELOPMENT CODES
ONLY. NO EFFORT WAS MADE TO CHECK THE STRUCTURAL, MECHANICAL, ELECTRICAL OR
PLUMBING DESIGN OTHER THAN TO COMPARE THE SUBMITTED PLANS WITH THE APPLICABLE
BUILDING CODES.
STRUCTURAL INTEGRITY DURING CONSTRUCTION IS THE TOTAL RESPONSIBILITY OF THE
OWNER AND THE OWNER'S AGENTS. THIS PERMIT IS SUBJECT TO ALL SANDY SPRINGS
ORDINANCES AND GEORGIA STATE LAWS.
A SITE PRE-CONSTRUCTION MEETING AND A BUILDING PRE-CONSTRUCTION MEETING ARE
REQUIRED AT THE BEGINNING OF THE PROJECT FOR ALL PERMITS EXCEPT TRADE PERMITS.
THE OWNER AND THE OWNER'S AGENT SHALL REQUEST AND PASS ALL INSPECTIONS PRIOR
TO THE CONCEALMENT OF WORK.
PERMIT
APPROVED
01/14/2024
3000 RIVER EXCHANGE DR
DESCRIPTION UNIT
QUANTITY
09-0001
DETAILED ESTIMATE
DETAILED ESTIMATE
001-5000 Utility Contingency - As Directed By Engineer LS 1
150-1000
163-0240
165-0010
171-0010
210-0100
441-0104
515-2020
441-0108
441-5002
610-6515
611-5551
643-8200
700-7000
700-8000
700-8100
700-9300
999-0001 Miscellaneous Construction Contingency As Directed By Engineer
Sod
Fertilizer Nitrogen Content
Fertilizer Mixed Grade
Agricultural Lime
Barrier Fence (Orange), 4 FT
Reset Sign
Remove Highway Sign, Standard
Conc Sidewalk, 8 IN
Conc Sidewalk, 4 IN
Grading Complete
Temporary Silt Fence, Type A
Maintenance of Temporary Silt Fence, TP A
Mulch
Traffic Control - Project LS
TN
LF
LS
LF
LF
SY
SY
LF
EA
EA
LF
TN
TN
LB
SY
LS 1
ITEM
PAY
441-5004 LF
Conc Header Curb, 10 IN, TP 4
Conc Header Curb, 6 IN, TP 2
Decorative Handrail
REVISION DATES
12/28/2023
Joe.Zerkus
GPLOT-V8
201926804_9-0001.dgn
12:31:23 PM
BACKCHECKED:
CORRECTED:
VERIFIED:
DATE:
DATE:
DATE:
SEGMENT 4 - RIVER EXCHANGE DRIVE
GA 30092
SANDY SPRINGS
3000 RIVER EXCHANGE DRIVE
12/28/2023
PERMITTED BY: _________________________________________ DATE: ______________________
PERMIT #: ___________________________________________________________________________
THESE PLANS WERE REVIEWED WITH RESPECT TO CITY BUILDING AND DEVELOPMENT CODES
ONLY. NO EFFORT WAS MADE TO CHECK THE STRUCTURAL, MECHANICAL, ELECTRICAL OR
PLUMBING DESIGN OTHER THAN TO COMPARE THE SUBMITTED PLANS WITH THE APPLICABLE
BUILDING CODES.
STRUCTURAL INTEGRITY DURING CONSTRUCTION IS THE TOTAL RESPONSIBILITY OF THE
OWNER AND THE OWNER'S AGENTS. THIS PERMIT IS SUBJECT TO ALL SANDY SPRINGS
ORDINANCES AND GEORGIA STATE LAWS.
A SITE PRE-CONSTRUCTION MEETING AND A BUILDING PRE-CONSTRUCTION MEETING ARE
REQUIRED AT THE BEGINNING OF THE PROJECT FOR ALL PERMITS EXCEPT TRADE PERMITS.
THE OWNER AND THE OWNER'S AGENT SHALL REQUEST AND PASS ALL INSPECTIONS PRIOR
TO THE CONCEALMENT OF WORK.
PERMIT
APPROVED
01/14/2024
3000 RIVER EXCHANGE DR
13-0001
CONSTRUCTION PLAN
GA 30092
SANDY SPRINGS
3000 RIVER EXCHANGE DRIVE
SCALE IN FEET
0 40 80
EASEMENT FOR CONSTR
EASEMENT FOR CONSTR OF SLOPES
EASEMENT FOR CONSTR OF DRIVES
CONSTRUCTION LIMITS
& MAINTENANCE OF SLOPES
REQUIRED R/W LINE
PROPERTY AND EXISTING R/W LINE
REVISION DATES
12/28/2023
Joe.Zerkus
GPLOT-V8
201926804_13-0001.dgn
12:31:31 PM
BACKCHECKED:
CORRECTED:
VERIFIED:
DATE:
DATE:
DATE:
DATE:
C F
PL
SIDEWALK GAP FILLS
SEGMENT 4 - RIVER EXCHANGE DRIVE
E X
IS
T
R
W
E X
IS
T
R
W
EXI
ST
R/ W
EXI
ST
R/ W
G W
IN
N E T T
C
O U
N T
Y
F U
L T
O N
C
O U
N T
Y
SI
DE
WAL
K
6’ SI
DEWALK
5’
8’ S
ID
EWAL
K
SIGN
DO NOT DISTURB
2’
RI
VE
R
EX
CHANGE
D
R
S P A L D I N G
D R
DRIVEWAY APRON
DO NOT DISTURB EXISTING
EXISTING SIGNAL POLE
DO NOT DISTURB
5’
2’
FIRE HYDRANT
DO NOT DISTURB
STA. 0+45.00, 39.77’ LT
BEGIN HANDRAIL
STA. 2+05.00, 29.69’ LT
SEE GDOT STD. 9032B
BEGIN GDOT TYPE 4 HEADER CURB
STA. 2+95.00, 20.97’ LT
SEE GDOT STD. 9032B
BEGIN GDOT TYPE 2 HEADER CURB
END GDOT TYPE 4 HEADER CURB
STA. 3+06.97, 21.47’ LT
SEE GDOT STD.9032B
END GDOT TYPE 2 HEADER CURB
STA. 3+28.92, 23.62’ LT
SEE GDOT STD. 9032B
BEGIN GDOT TYPE 4 HEADER CURB
STA. 3+83.34, 21.26’ LT
SEE GDOT STD.9032B
END GDOT TYPE 4 HEADER CURB
STA. 0+12.71
BEGIN CONSTRUCTION
STA. 3+31.32, 17.01’ LT
TIE TO EXISTING DRIVEWAY APRON
BEGIN 6’ SIDEWALK
STA. 0+85.00, 39.66’ LT
END HANDRAIL
STA. 3+83.31
END CONSTRUCTION
E. 2267245.2500
N. 1442686.2300
STA. 0+00
BEGIN PROJECT
E: 2267082.7383
N: 1443093.6563
STA. 4+50.00
END PROJECT
D.S.= 0
E= 27.69
R= 320.00
L= 257.14
T= 135.97
E= 2267055.4622
N= 1442994.3428
PI Sta= 3+61.87
Curve# 1
Cur ve#
19.44’ LT
STA. 2+64.04
BEGIN SIDEWALK TAPER
END 10’ SIDEWALK
STA. 3+06.77, 14.95’ LT
TIE TO EXISTING DRIVEWAY APRON
END 6’ SIDEWALK
STA. 3+83.31, 16.76’ LT
TIE TO EXISTING
END SIDEWALK TAPER
15.40’ LT
STA. 2+87.29
8’ SIDEWALK
SIDEWALK TAPER
14.46’ LT
STA. 2+95.00
BEGIN 6’ SIDEWALK
END SIDEWALK TAPER
16.64’ LT
STA. 3+63.40
BEGIN SIDEWALK TAPER
END 6’ SIDEWALK
REMOVED BY OTHERS
W20-1 SIGN TO BE
2’ 5’
5’
P
P T
P I
R=21.06’
30.42’ LT
STA. 1+00.50
BEGIN SIDEWALK TAPER
END 8’ SIDEWALK
38.54’ LT
STA. 1+07.83
END SIDEWALK TAPER
BEGIN 10’ SIDEWALK
STA. 0+12.71, 36.06’ LT
TIE TO EXISTING
BEGIN SIDEWALK
38.95’ LT
STA. 0+25.02
BEGIN 8’ SIDEWALK
END SIDEWALK TAPER
STA. 0+15.89, 41.08’ LT
TIE TO EXISTING
BEGIN SIDEWALK TAPER
STA 2+73
W3-3 SIGN
REMOVE AND RESET
D.B. 59288, PG. 17
PID: 06 0313 LL0364
CITY OF SANDY SPRINGS
12/28/2023
PERMITTED BY: _________________________________________ DATE: ______________________
PERMIT #: ___________________________________________________________________________
THESE PLANS WERE REVIEWED WITH RESPECT TO CITY BUILDING AND DEVELOPMENT CODES
ONLY. NO EFFORT WAS MADE TO CHECK THE STRUCTURAL, MECHANICAL, ELECTRICAL OR
PLUMBING DESIGN OTHER THAN TO COMPARE THE SUBMITTED PLANS WITH THE APPLICABLE
BUILDING CODES.
STRUCTURAL INTEGRITY DURING CONSTRUCTION IS THE TOTAL RESPONSIBILITY OF THE
OWNER AND THE OWNER'S AGENTS. THIS PERMIT IS SUBJECT TO ALL SANDY SPRINGS
ORDINANCES AND GEORGIA STATE LAWS.
A SITE PRE-CONSTRUCTION MEETING AND A BUILDING PRE-CONSTRUCTION MEETING ARE
REQUIRED AT THE BEGINNING OF THE PROJECT FOR ALL PERMITS EXCEPT TRADE PERMITS.
THE OWNER AND THE OWNER'S AGENT SHALL REQUEST AND PASS ALL INSPECTIONS PRIOR
TO THE CONCEALMENT OF WORK.
PERMIT
APPROVED
01/14/2024
3000 RIVER EXCHANGE DR
13T-0001
CONSTRUCTION PLAN
HARDWOOD-12"
HARDWOOD-18"
HARDWOOD-12"
HARDWOOD-24"
HARDWOOD-8"
HARDWOOD-12"
HARDWOOD-30"
HARDWOOD-24"
HARDWOOD-18"
HARDWOOD-12"
HARDWOOD-6"
HARDWOOD-6"
HARDWOOD-6"
HARDWOOD-6"
HARDWOOD-12"
HARDWOOD-6"
HARDWOOD-6"
HARDWOOD-8"
PINE-8"
HARDWOOD-8"
HARDWOOD-8"
HARDWOOD-8"
HARDWOOD-30"
HARDWOOD-18"
HARDWOOD-20"
HARDWOOD-28"
HARDWOOD-8"
PINE-6"
PINE-6"
TREE TO BE REMOVED
CRZ TO BE PROTECTED BY ORANGE BARRIER FENCE
LIMIT OF CRZ
ZONE (CRZ) ENCROACHMENT INTO DISTURBED AREA
TREE HAS GREATER THAN 25% OF THE CRITICAL ROOT1
LEGEND
HARDWOOD-12"
HARDWOOD-12"
HARDWOOD-15"
DISTURBED
CRZ 26%
SEE NOTE 1
HARDWOOD-6"
HARDWOOD-8"
HARDWOOD-6"
HARDWOOD-8"
HARDWOOD-8"
GA 30092
SANDY SPRINGS
3000 RIVER EXCHANGE DRIVE
HARDWOOD-24"
SCALE IN FEET
0 40 80
EASEMENT FOR CONSTR
EASEMENT FOR CONSTR OF SLOPES
EASEMENT FOR CONSTR OF DRIVES
CONSTRUCTION LIMITS
& MAINTENANCE OF SLOPES
REQUIRED R/W LINE
PROPERTY AND EXISTING R/W LINE
REVISION DATES
12/28/2023
Joe.Zerkus
GPLOT-V8
201926804_13T-0001.dgn
12:31:39 PM
BACKCHECKED:
CORRECTED:
VERIFIED:
DATE:
DATE:
DATE:
DATE:
C F
PL
SIDEWALK GAP FILLS
SEGMENT 4 - RIVER EXCHANGE DRIVE
E X
IS
T
R
W
E X
IS
T
R
W
EXI
ST
R/ W
EXI
ST
R/ W
G W
IN
N E T T
C
O U
N T
Y
F U
L T
O N
C
O U
N T
Y
RI
VE
R
EX
CHANGE
D
R
S P A L D I N G
D R
D.B. 59288, PG. 17
PID: 06 0313 LL0364
CITY OF SANDY SPRINGS
12/28/2023
PERMITTED BY: _________________________________________ DATE: ______________________
PERMIT #: ___________________________________________________________________________
THESE PLANS WERE REVIEWED WITH RESPECT TO CITY BUILDING AND DEVELOPMENT CODES
ONLY. NO EFFORT WAS MADE TO CHECK THE STRUCTURAL, MECHANICAL, ELECTRICAL OR
PLUMBING DESIGN OTHER THAN TO COMPARE THE SUBMITTED PLANS WITH THE APPLICABLE
BUILDING CODES.
STRUCTURAL INTEGRITY DURING CONSTRUCTION IS THE TOTAL RESPONSIBILITY OF THE
OWNER AND THE OWNER'S AGENTS. THIS PERMIT IS SUBJECT TO ALL SANDY SPRINGS
ORDINANCES AND GEORGIA STATE LAWS.
A SITE PRE-CONSTRUCTION MEETING AND A BUILDING PRE-CONSTRUCTION MEETING ARE
REQUIRED AT THE BEGINNING OF THE PROJECT FOR ALL PERMITS EXCEPT TRADE PERMITS.
THE OWNER AND THE OWNER'S AGENT SHALL REQUEST AND PASS ALL INSPECTIONS PRIOR
TO THE CONCEALMENT OF WORK.
PERMIT
APPROVED
01/14/2024
3000 RIVER EXCHANGE DR
UTILITY PLANS
24-0001
GA 30092
SANDY SPRINGS
3000 RIVER EXCHANGE DRIVE
SCALE IN FEET
0 40 80
EASEMENT FOR CONSTR
EASEMENT FOR CONSTR OF SLOPES
EASEMENT FOR CONSTR OF DRIVES
CONSTRUCTION LIMITS
& MAINTENANCE OF SLOPES
C F
REQUIRED R/W LINE
PROPERTY AND EXISTING R/W LINE PL
REVISION DATES
12/28/2023
Joe.Zerkus
GPLOT-V8
201926804_24-0001.dgn
12:31:54 PM
BACKCHECKED:
CORRECTED:
VERIFIED:
DATE:
DATE:
DATE:
DATE:
P.I. No.
S2188
SIDEWALK GAP FILLS
SEGMENT 4 - RIVER EXCHANGE DRIVE
G W
IN
N E T T
C
O U
N T
Y
F U
L T
O N
C
O U
N T
Y
A G L
" P
L S
A G L
" S
T L
AL-
34N
2L6 -02
4F
AL-
34N
2L6 -02
4DUCT
-1
DUC
T-
DUC
T-
MH SD12
MH RED1
8" D
IP
SIGN
DO NOT DISTURB
RI
VE
R
EX
CHANGE
D
R
S P A L D I N G
D R
DRIVEWAY APRON
DO NOT DISTURB EXISTING
EXISTING SIGNAL POLE
DO NOT DISTURB
FIRE HYDRANT
DO NOT DISTURB
E. 2267245.2500
N. 1442686.2300
STA. 0+00
BEGIN PROJECT
E: 2267082.7383
N: 1443093.6563
STA. 4+50.00
END PROJECT
REMOVED BY OTHERS
W20-1 SIGN TO BE
STA 2+73
W3-3 SIGN
REMOVE AND RESET
CONS
T.
E
SMT
CONS
T.
E
SMT
RE
Q’
D R/
W
RE
Q’
D R/
W
D.B. 59288, PG. 17
PID: 06 0313 LL0364
CITY OF SANDY SPRINGS
GRADE
VALVE TO
ADJUST WATER
A
P
D I P
12/28/2023
PERMITTED BY: _________________________________________ DATE: ______________________
PERMIT #: ___________________________________________________________________________
THESE PLANS WERE REVIEWED WITH RESPECT TO CITY BUILDING AND DEVELOPMENT CODES
ONLY. NO EFFORT WAS MADE TO CHECK THE STRUCTURAL, MECHANICAL, ELECTRICAL OR
PLUMBING DESIGN OTHER THAN TO COMPARE THE SUBMITTED PLANS WITH THE APPLICABLE
BUILDING CODES.
STRUCTURAL INTEGRITY DURING CONSTRUCTION IS THE TOTAL RESPONSIBILITY OF THE
OWNER AND THE OWNER'S AGENTS. THIS PERMIT IS SUBJECT TO ALL SANDY SPRINGS
ORDINANCES AND GEORGIA STATE LAWS.
A SITE PRE-CONSTRUCTION MEETING AND A BUILDING PRE-CONSTRUCTION MEETING ARE
REQUIRED AT THE BEGINNING OF THE PROJECT FOR ALL PERMITS EXCEPT TRADE PERMITS.
THE OWNER AND THE OWNER'S AGENT SHALL REQUEST AND PASS ALL INSPECTIONS PRIOR
TO THE CONCEALMENT OF WORK.
PERMIT
APPROVED
01/14/2024
3000 RIVER EXCHANGE DR
SPECIAL CONSTRUCTION DETAIL
38-
N.T.S.
FOR APPROVAL BY THE ENGINEER.
C. AN EQUIVALENT PRODUCT MAY BE SUBMITTED
OF THE CITY OF SANDY SPRINGS.
B. STYLE AND PANEL OPTION AT THE DISCRETION
SEE PLAN SHEETs FOR LOCATION.
TO PROVIDE SHOP DRAWING FOR POST ANCHORING.
SPECIFICATIONS, 7TH EDITION, 2014. CONTRACTOR
BE DESIGNED PER SECTION 13.8 OF THE AASHTO LRFD
ATTACHMENT TO THE TURNDOWN SIDEWALK SHOULD
NOTES: A. THE PEDESTRIAN RAILING AND THE MEANS OF
FENCING DETAIL
PEDESTRIAN HANDRAIL/DECORATIVE
12/28/2023
Joe.Zerkus
GPLOT-V8
201926804_38-0001.dgn
12:31:56 PM
BACKCHECKED:
CORRECTED:
VERIFIED:
DATE:
DATE:
DATE:
DATE:
P.I. No.
SIDEWALK GAP FILLS
SEGMENT 4 - RIVER EXCHANGE DRIVE
S2188
12/28/2023
PERMITTED BY: _________________________________________ DATE: ______________________
PERMIT #: ___________________________________________________________________________
THESE PLANS WERE REVIEWED WITH RESPECT TO CITY BUILDING AND DEVELOPMENT CODES
ONLY. NO EFFORT WAS MADE TO CHECK THE STRUCTURAL, MECHANICAL, ELECTRICAL OR
PLUMBING DESIGN OTHER THAN TO COMPARE THE SUBMITTED PLANS WITH THE APPLICABLE
BUILDING CODES.
STRUCTURAL INTEGRITY DURING CONSTRUCTION IS THE TOTAL RESPONSIBILITY OF THE
OWNER AND THE OWNER'S AGENTS. THIS PERMIT IS SUBJECT TO ALL SANDY SPRINGS
ORDINANCES AND GEORGIA STATE LAWS.
A SITE PRE-CONSTRUCTION MEETING AND A BUILDING PRE-CONSTRUCTION MEETING ARE
REQUIRED AT THE BEGINNING OF THE PROJECT FOR ALL PERMITS EXCEPT TRADE PERMITS.
THE OWNER AND THE OWNER'S AGENT SHALL REQUEST AND PASS ALL INSPECTIONS PRIOR
TO THE CONCEALMENT OF WORK.
PERMIT
APPROVED
01/14/2024
3000 RIVER EXCHANGE DR
P. I. NumberGDQT Georgia Department of Transportation
RAISED EDGE WITH CONCRETE GUTTER CONCRETE MEDIAN (Between Curbs)
NOTE: CURB TYPES SHOWN ARE TYPICAL.
OTHER TYPES MAY BE SPECIFIED.
CONCRETE MEDIANS (Integral)r FACE OF CURB MUST ALIGN
WITH BACK EDGE OF GUARDRAIL
AND THE FACE OF THE OFFSET
BLOCK. -WITH TIE BARS- -WITHOUT TIE BARS-
2/ SLOPE TYPE 2 CURB FACE
SHOWN OTHER TYPE
MAY BE SPECIFIED \*|
TYPE I CURB FACE
SHOWN OTHER TYPETYPICAL '/?" EXP.
/ JOINT
27/2" EXP. JOINT 27.4" SLOPE TYPICAL MAY BE SPECIFIEDI" R K 9" H i SLOPE TYPICAL itM SLOPF >^13" A C*hSURFACE
COURSE
THICKNESS
SURFACE
COURSE
f THICKNESS
F -3ieiii=iii-'.ii I T rht I M. J
=1) 1=1J 1=171=6" OR 8" - JTZt>4" L!l=l)17=1)I=uI =i)tt)i=m= TV V 3U3UffilO~IUA ®PAVEMENT ®PAVEMENTMIN.r
%"R-I 6
COMPACTED
EARTH FILL
2'-6 *4 TIE BARS S
3 FT. C. TO C.
i
*3 BARS AT 12" C. +0 C. BOTH WAYS OR
6 x 6-W2.9 x W2.9 WELDED WIRE FABRIC OR 4 x 4-W2.0 x W2.0 WELDED WIRE FABRIC
NOTE:
WIDTH OF CONCRETE MEDIAN WILL BE AS SHOWN IN PLANSm=ni RAISED EDGE TO BE CONSTRUCTED WITH SAME CONCRETE MIX AS
THE GUTTER AND SHALL BE FORMED MONOLITHIC WITH GUTTER.
JOINTS IN RAISED EDGE SHALL MATCH THOSE IN THE GUTTER.
, 11 ii NOTE:
IF FINAL SURFACE COURSE IS PRESENT OR MUST BE INSTALLED BEFORE THE CONCRETE MEDIAN CAN
BE INSTALLED, THEN DOWELED IN CONCRETE MEDIAN IS REQUIRED.
ii ii ii ii
NOTE:
IF CONCRETE MEDIAN INTERCEPTS PEDESTRIAN CROSSWALKS, WHEELCHAIR RAMPS (CONSTRUCTION DETAIL A-3 AND A-4) WILL BE REQUIRED.TYPE 8
TYPE 8 HEADER CURB IS USED
IN CONJUNCTION WITH GUARDRAIL
CONNECTIONS TO CONCRETE
BARRIER AS NOTED ON GA. STD.
4382.
CONCRETE DOWELED INTEGRAL CURBS8" h-3!0" -i — 2/2CONCRETE CURB & GUTTER I OR 1 *2" H4'K■6" K J Ir I" R -2-R
87 SLOPE 87 SLOPE x/® PAVEMENT
7 /
«4 TIE BARS.
0 3' C. TO C.
TYPE I
‘82 SLOPE h w-h hL h X «4 TIE BARS6'' 6" * 6" 6"*
OR ^ -T T
/4pa\/ement^J2IJ,c- to c-
TYPE 2, 3 OR A
; *4 TIE BARSOR OR ^ OR - ' A • A • ’ A • ^PAVEMENTMb" , // 0 3' C. TO C.8"P 8" rL- H K 2/2T T* *CURB * * * * * * TYPE 6d VAR. 2'-6" MIN.
5I/^k- 1%" TYPE VAR. 2'-6'' MIN. VAR. 2'-6'' MIN. VAR. 2'-8" MIN. r13" OR d" S" rnin. 2"R hTYPE I TYPE 2, 3 OR A TYPE 7 TYPE 9 2"2 6" 8" min. OR I" i
77777V77777, ^PAVEMENT
T3 10" min.
12" min.
7" min.
“4 TIE BARS«4 TIE BARS^PAVEMENT > //| © 3' C. TO C.10" © 3' C. TO C.
H h- 2/26 6' 3"U-* * AT CONTRACTOR'S OPTION THE GUTTER THICKNESS MAY BE INCREASED AT EDGE OF PAVEMENT TO MAKE BOTTOM OF GUTTER PARALLEL WITH PAVING
OF BASE COURSE, BUT THE GUTTER THICKNESS MUST NOT BE LESS THAN THE SPECIFIED 6" OR 8'' AT ANY POINT.
WHEN POSITIVE SUPERELEVATION IS REQUIRED, THE SLOPE OF THE GUTTER ON THE HIGH SIDE SHALL BE A CONTINUATION
OF THE SLOPE OF THE SUPERELEVATED PAVEMENT.
7 6" 8" min. TYPE 9TYPE 79 3" OR 4" 8" min.
NOTES:
1. CONCRETE CURB CAN BE INSTALLED AFTER INTIAL SET AS LONG AS
TIE BARS ARE DRILLED INTO UNDERLAYING CONCRETE PAVEMENT.
2. CONCRETE CURB CAN BE INSTALLED BEFORE INITIAL SET WITH
DOWELS THAT ARE DRIVEN INTO UNDERLYING CONCRETE PAVMENT.
3. JOINTS IN CURB AND CONCRETE MEDIAN WILL MATCH THOSE IN THE
CONCRETE PAVEMENT.
4. ALL TYPES OF CONCRETE CURB CAN BE PLACED ON ASPHALT
PAVEMENTS WHERE TIE BARS MAY BE EITHER DRIVEN OR DRILLED
INTO THE UNDERLYING PAVEMENT. CONTRACTION JOINTS SHALL BE
CONSTRUCTED IN CURB OR CONCRETE MEDAIN AT 20 FT. SPACING.
5. TIE BARS FOR DOWELED CURBS MAY BE UNCOATED PLAIN OR
DEFORMED BILLET-STEEL BARS (GRADE 40)AS USED FOR CONCRETE
REINFORCEMENT. (AASHTO M-31)
MINIMUM TIE BAR LENGTHS
(FOR CONC. DOWELED CURBS
OR CONC. MEDIAN)
CURB TYPEP.C. CONC.
PAV.
ASPHALT
PAV.
6" 8"I
2, 3 OR 4 12"CURB FACE DESIGNDETAILS OF RECESSED CURB FOR DRIVEWAYS 6 6“ 8-
7 6" 8’
6‘ 8"
ISOMETRICSTD. CURB
& GUTTER VIEW
CONCRETE INTEGRAL CURBr RATTFR
— 5'/a" —| h7/s"M'H4/ie" - 5/s"y yb/s"r,iI i TRANSITION CURB HEIGHT i I 2"R f Th PLUS
THICKNESS
OF SURFACE
J-COURSE
h PLUS
THICKNESS
OF SURFACE
COURSE
FROM h TO 2". 61° 2"R SURFACE
COURSE
THICKNESS
XI h 0"^-2"R 2"Rh h h 3" R hi X -=firrh '44°L I 44° ” 2" R , SURFACE
COURSE
THICKNESS!
hV. 3"R I" Tl"RJ 7"-h— 6" —H I-DRIVEWAYS k 6" k 12" ■8"—-IO'' FOR h=3"lV, 0" FOR h=3'' I'' FOR h=4"I'' FOR h=4"
TYPE ITYPE I TYPE 2, 3 OR A TYPE 6 TYPE 7 TYPE 9 TYPE 7
8" i h PLUS
THICKNESS
OF SURFACE
COURSE
T h ’ r ■ .
♦ OR rl^l"R °'aSURFACE
COURSE
THICKNESS!-
NOTE: CURB & GUTTER WILL BE MEASURED
FOR PAYMENT THRU THE DRIVE
CONCRETE HEADER CURBS
TYPE 9
r\i o DEPARTMENT OF TRANSPORTATION
STATE OF GEORGIA
<\JC\l2" LT> oJ T
\ TRANSITION CURB HEIGHT
FROM h TO 2".
87 SLOPE r t i O (£?o CVI CNJ h h hh CNJh ott; ^pavement 7; 7 d-o o
ENT
113T y; ‘ t yy.T- ' -T.6" OR MIN. OD 7 UjPAVEM <cqPAVEMENT7 - . , 7 d-;.
k7"L
7 o8X PAVEMENTd-'PAVEMENT/ „ d s oPAVEMENT =3 STANDARD
CONCRETE CURB & GUTTER
CONCRETE CURBS, CONCRETE MEDIANS
CTl CD CD
J QD OlOo. CLoJ5 ce CD CQ ce §-A 6" k- CDCD QD6" k 5cc ccccq dD oq CT>LD QLu y y 8LD CD OS cn crCD<oTYPE I TYPE 2, 3 OR 4 TYPE 7 TYPE 9
TRUCK APRON
IN ROUNDABOUTS
TYPE 6 L] Q-s >a.CTla: of o CDQ-ya. LD >-a.ySECTIONAL VIEW >CJy CD Q yLDQ y cr.CD Qy CD
Cu > CD NOT TO SCALE MAR. 20035SECTION A-A ct 9U. Qce y yy o
NUMBER(SUBMITTED)DES.
STATE DESIGN POLICY'ENGINEER
CHIEF ENGINEER
cr DRW____
TRA____
Cl. Q_ OO 9032B(SEE SEPARATE CONSTRUCTION DETAILS FOR DRIVEWAYS) THE DIMENSION d MAY BE INCREASED AT CONTRACTOR'S OPTION SO BOTTOM OF HEADER CURB WILL ALIGN WITH BOTTOM OF PAVEMENT TYPICAL SECTION. o (APPROVED) uo
CHK.
12/28/2023
PERMITTED BY: _________________________________________ DATE: ______________________
PERMIT #: ___________________________________________________________________________
THESE PLANS WERE REVIEWED WITH RESPECT TO CITY BUILDING AND DEVELOPMENT CODES
ONLY. NO EFFORT WAS MADE TO CHECK THE STRUCTURAL, MECHANICAL, ELECTRICAL OR
PLUMBING DESIGN OTHER THAN TO COMPARE THE SUBMITTED PLANS WITH THE APPLICABLE
BUILDING CODES.
STRUCTURAL INTEGRITY DURING CONSTRUCTION IS THE TOTAL RESPONSIBILITY OF THE
OWNER AND THE OWNER'S AGENTS. THIS PERMIT IS SUBJECT TO ALL SANDY SPRINGS
ORDINANCES AND GEORGIA STATE LAWS.
A SITE PRE-CONSTRUCTION MEETING AND A BUILDING PRE-CONSTRUCTION MEETING ARE
REQUIRED AT THE BEGINNING OF THE PROJECT FOR ALL PERMITS EXCEPT TRADE PERMITS.
THE OWNER AND THE OWNER'S AGENT SHALL REQUEST AND PASS ALL INSPECTIONS PRIOR
TO THE CONCEALMENT OF WORK.
PERMIT
APPROVED
01/14/2024
3000 RIVER EXCHANGE DR
PERMITTED BY: _________________________________________ DATE: ______________________
PERMIT #: ___________________________________________________________________________
THESE PLANS WERE REVIEWED WITH RESPECT TO CITY BUILDING AND DEVELOPMENT CODES
ONLY. NO EFFORT WAS MADE TO CHECK THE STRUCTURAL, MECHANICAL, ELECTRICAL OR
PLUMBING DESIGN OTHER THAN TO COMPARE THE SUBMITTED PLANS WITH THE APPLICABLE
BUILDING CODES.
STRUCTURAL INTEGRITY DURING CONSTRUCTION IS THE TOTAL RESPONSIBILITY OF THE
OWNER AND THE OWNER'S AGENTS. THIS PERMIT IS SUBJECT TO ALL SANDY SPRINGS
ORDINANCES AND GEORGIA STATE LAWS.
A SITE PRE-CONSTRUCTION MEETING AND A BUILDING PRE-CONSTRUCTION MEETING ARE
REQUIRED AT THE BEGINNING OF THE PROJECT FOR ALL PERMITS EXCEPT TRADE PERMITS.
THE OWNER AND THE OWNER'S AGENT SHALL REQUEST AND PASS ALL INSPECTIONS PRIOR
TO THE CONCEALMENT OF WORK.
PERMIT
APPROVED
01/14/2024
3000 RIVER EXCHANGE DR
PERMITTED BY: _________________________________________ DATE: ______________________
PERMIT #: ___________________________________________________________________________
THESE PLANS WERE REVIEWED WITH RESPECT TO CITY BUILDING AND DEVELOPMENT CODES
ONLY. NO EFFORT WAS MADE TO CHECK THE STRUCTURAL, MECHANICAL, ELECTRICAL OR
PLUMBING DESIGN OTHER THAN TO COMPARE THE SUBMITTED PLANS WITH THE APPLICABLE
BUILDING CODES.
STRUCTURAL INTEGRITY DURING CONSTRUCTION IS THE TOTAL RESPONSIBILITY OF THE
OWNER AND THE OWNER'S AGENTS. THIS PERMIT IS SUBJECT TO ALL SANDY SPRINGS
ORDINANCES AND GEORGIA STATE LAWS.
A SITE PRE-CONSTRUCTION MEETING AND A BUILDING PRE-CONSTRUCTION MEETING ARE
REQUIRED AT THE BEGINNING OF THE PROJECT FOR ALL PERMITS EXCEPT TRADE PERMITS.
THE OWNER AND THE OWNER'S AGENT SHALL REQUEST AND PASS ALL INSPECTIONS PRIOR
TO THE CONCEALMENT OF WORK.
PERMIT
APPROVED
01/14/2024
3000 RIVER EXCHANGE DR
EROSION CONTROL LEGEND
52-0001
3/2/2017
CONTROL IN GEORGIA".
REFER TO THE LATEST EDITION OF THE GEORGIA SOIL AND WATER CONSERVATION COMMISSION’S, "MANUAL FOR EROSION AND SEDIMENT
2. FOR ADDITIONAL INFORMATION ON THE DESIGN AND APPLICATION OF EROSION AND SEDIMENT CONTROL BEST MANAGEMENT PRACTICES (BMPs),
1. DO NOT USE EROSION CONTROL ITEMS IN A FLOWING STREAM OR IN A TIDAL AREA BELOW HIGH TIDE.
NOTE:
FENCE.
WHEN NECESSARY, BUFFER ZONES ARE TO BE PROTECTED BY ORANGE BARRIER
WETLANDS, LAKES, AND COASTAL WATERS.
SURROUNDING AN AREA OF DISTURBANCE OR BORDERING STREAMS, PONDS,
EXISTING VEGETATION, OR THE RE-ESTABLISHMENT OF VEGETATION
A STRIP OF UNDISTURBED ORIGINAL VEGETATION, ENHANCED OR RESTORED
Ds1
Ds2
Ds3
Ds4
Sb OTHER PLANTING DETAILS.
STREAM BUFFER MITIGATION PLANS FOR PLANT SPECIES, LOCATIONS, AND
APPLICABLE TO THE PROJECT. REFER TO THE PROJECT’S STREAM AND
STREAMBANK STABILIZATION AREAS SHOULD BE SHOWN ON THE PLANS WHEN
OR RESTORE AND REPAIR SMALL STREAMBANK EROSION PROBLEMS.
PLANT MATERIALS TO MAINTAIN AND ENHANCE STREAMBANKS, OR TO PREVENT,
STREAMBANK STABILIZATION IS THE USE OF READILY AVAILABLE NATIVE
FENCE
BARRIER
ORANGE
LINE CODE
ORANGE BARRIER FENCE
ESA
SENSITIVE AREA
ENVIRONMENTALLY
ESA-25’(OR 50’)STREAM BUFFER,ETC.
Bf
Bf
BfBUFFER ZONE
SYMBOL
Bf
SECTION 163,700
GRASSING
SECTION 163
MULCH
Sb
Ds4
PATTERN
Fl-Co
SECTION 700
GRASSING
PERMANENT
POLYACRYLAMIDE
SECTION 163,700,
COAGULANTS
FLOCCULANTS
SYMBOL
Fl-Co
PROVISIONS AND APPLICABLE PLAN NOTES.
ACCORDANCE WITH SECTION 107 AND ANY OTHER APPLICABLE SPECIAL
IF WORK IS AUTHORIZED IN THIS AREA, THE WORK MUST BE PERFORMED IN
HABITATS.
SITES, ARCHAEOLOGICAL SITES, AND PROTECTED ANIMAL AND PLANT SPECIES
INCLUDE, BUT ARE NOT LIMITED TO: STATE WATER BUFFERS, HISTORIC
ENVIRONMENTALLY, CULTURALLY, OR HISTORICALLY SENSITIVE. ESAs
AN ENVIRONMENTALLY SENSITIVE AREA (ESA) CONTAINS RESOURCES THAT ARE
REVISION DATES
3/2/2017 cbaird
GPLOT-V8
EC-L(sheets 1-7).dgn
11:08:40 AM
GPLN7/31/2015
BACKCHECKED:
CORRECTED:
VERIFIED:
DATE:
DATE:
DATE:
SHEET 1 OF 7
UNIFORM CODE SHEET
01/01/16D. EAGLETON
Ds1
Ds2
Ds3
SECTION 702
STABILIZATION
STREAMBANK
USED IN CONJUNCTION WITH. NO SEPARATE PAYMENT WILL BE MADE.
THE PRICE FOR THE INSTALLATION AND/OR MAINTENANCE OF THE BMP IT IS
BMP IF NEEDED. PAYMENT FOR PAM AS A FLOCCULANT WILL BE INCLUDED IN
FLOCCULANTS/COAGULANTS ARE TO BE SHOWN ON PLANS WITH APPLICABLE
BE USED DOWNSTREAM OF AFOREMENTIONED BMPs!
SEDIMENT BASIN, OR TEMPORARY SEDIMENT TRAP. FLOCCULANTS SHALL NOT
WITHIN CHANNELS UPSTREAM OF A POST-CONSTRUCTION POND, TEMPORARY
ANIONIC POLYACRYLAMIDES (PAM) MAY BE USED IN CONJUNCTION WITH BMPs
CONSTRUCTION SITES FOR WATER CLARIFICATION.
HEAVY METALS, AND HYDROCARBONS (TSS) IN SLOW MOVING RUNOFF FROM
FLOCCULANTS AND COAGULANTS ARE USED TO SETTLE SUSPENDED SEDIMENT,
ON APPLICABLE SHEETS IN SECTION 54.
THE BMP SYMBOL FOR APPLICABLE AREAS AND/OR A NOTE SHALL BE INCLUDED
AND/OR THE PROJECT ENGINEER.
MULCHING REQUIREMENTS ARE ADDRESSED BY STANDARD SPECIFICATIONS
STABILIZE AREAS PRIOR TO FINAL GRADING.
WHERE PERMANENT VEGETATION IS OUT OF SEASON OR TO TEMPORARILY
AND STABILIZE THE SOIL. IT IS USED TO CONTROL EROSION IN AREAS
THIS IS AN APPLICATION OF STRAW MULCH USED TO REDUCE SOIL EROSION
ON APPLICABLE SHEETS IN SECTION 54.
THE BMP SYMBOL FOR APPLICABLE AREAS AND/OR A NOTE SHALL BE INCLUDED
STANDARD SPECIFICATIONS.
TEMPORARY GRASSING SHOULD BE USED ON ALL PROJECTS ACCORDING TO THE
LONGER THAN MULCHING IS EXPECTED TO LAST.
AND SEASON. IT IS TYPICALLY USED TO CONTROL EROSION IN AREAS
THE SOWING OF A QUICK GROWING SPECIES OF GRASS SUITABLE TO THE AREA
ON APPLICABLE SHEETS IN SECTION 54.
THE BMP SYMBOL FOR APPLICABLE AREAS AND/OR A NOTE SHALL BE INCLUDED
STANDARD SPECIFICATION.
PERMANENT VEGETATION SHALL BE USED ON ALL PROJECTS ACCORDING TO THE
AREA AND SEASON.
THE SOWING OF PERMANENT VEGETATION, SUCH AS GRASS, SUITABLE TO THE
NO SCALE
CODE DETAIL DESCRIPTION
SPEC. SECT.
STD OR DETAIL
PRACTICE
CODE DETAIL DESCRIPTION
SPEC. SECT.
STD OR DETAIL
PRACTICE
MATERIALS OR EQUIPMENT WITHIN THIS AREA.
WHERE THE CONTRACTOR SHALL NOT CLEAR, GRUB, OR PLACE CONSTRUCTION
ORANGE BARRIER FENCE DELINEATES ENVIRONMENTALLY SENSITIVE AREAS
SECTION 700,890
DETAIL D-54
CONSTRUCTION
SODDING
INCLUDED ON APPLICABLE SHEETS IN SECTION 54.
THE BMP PATTERN FOR APPLICABLE AREAS AND/OR A NOTE SHALL BE
ENVIRONMENTAL COMMITMENTS OR LANDSCAPING REQUIREMENTS.
AESTHETICS, OR FOR SPECIAL PLANTING REQUIREMENTS ON THE BASIS OF
SODDING MAY BE SHOWN FOR HIGHLY SENSITIVE AREAS, TO IMPROVE
AND SEASON TO PROVIDE IMMEDIATE PERMANENT VEGETATION.
THE INSTALLATION OF A SPECIES OF GRASS SODDING SUITABLE TO THE AREA
12/28/2023
PERMITTED BY: _________________________________________ DATE: ______________________
PERMIT #: ___________________________________________________________________________
THESE PLANS WERE REVIEWED WITH RESPECT TO CITY BUILDING AND DEVELOPMENT CODES
ONLY. NO EFFORT WAS MADE TO CHECK THE STRUCTURAL, MECHANICAL, ELECTRICAL OR
PLUMBING DESIGN OTHER THAN TO COMPARE THE SUBMITTED PLANS WITH THE APPLICABLE
BUILDING CODES.
STRUCTURAL INTEGRITY DURING CONSTRUCTION IS THE TOTAL RESPONSIBILITY OF THE
OWNER AND THE OWNER'S AGENTS. THIS PERMIT IS SUBJECT TO ALL SANDY SPRINGS
ORDINANCES AND GEORGIA STATE LAWS.
A SITE PRE-CONSTRUCTION MEETING AND A BUILDING PRE-CONSTRUCTION MEETING ARE
REQUIRED AT THE BEGINNING OF THE PROJECT FOR ALL PERMITS EXCEPT TRADE PERMITS.
THE OWNER AND THE OWNER'S AGENT SHALL REQUEST AND PASS ALL INSPECTIONS PRIOR
TO THE CONCEALMENT OF WORK.
PERMIT
APPROVED
01/14/2024
3000 RIVER EXCHANGE DR
52-0002
3/2/2017
11/28/2018
CONTROL IN GEORGIA".
REFER TO THE LATEST EDITION OF THE GEORGIA SOIL AND WATER CONSERVATION COMMISSION’S, "MANUAL FOR EROSION AND SEDIMENT
2. FOR ADDITIONAL INFORMATION ON THE DESIGN AND APPLICATION OF EROSION AND SEDIMENT CONTROL BEST MANAGEMENT PRACTICES (BMPs), Ss
SECTION 716
DETAIL D-35
CONSTRUCTION
STABILIZATION
SLOPE
Tac
SECTION 171
DETAIL D-24D
CONSTRUCTION
CHECK DAM
FABRIC
Cd-Fs
Cd-Hb
Cd-S
Ch-1
Ch-2R1
Ch-2R3
TYPICALLY NOT SHOWN IN PLANS.
ADDITIONAL EROSION CONTROL MEASURES MAY BE REQUIRED.
DESIGNED IN ACCORDANCE WITH THE GDOT CHANNEL LINING DESIGN PROGRAM.
ONLY FOR VELOCITIES UP TO 5.0 fps. THIS MEASURE SHALL BE
A NEW OR EXISTING CHANNEL MAY BE LINED WITH PERMANENT VEGETATION
Ss
FL
OW
Cd-Hb
Ch-1
Ch-2R1
SYMBOL
Cd-S
SYMBOL
SYMBOL
Cd-Fs
Cd-F
Cd-F
Ch-2R3
700, 895
SECTION 163,
TACKIFIERS
POLYACRYLAMIDE
Tac
FL
OW
USED AT THE DOWNSTREAM DISCHARGE POINT.
WITHOUT A SEDIMENT BASIN, A MINIMUM OF ONE ROCK FILTER DAM SHALL BE
IF THIS ITEM IS USED IN AN AREA WITH FLOWS GREATER THAN 2.0-CFS OR
CONTROL IN GEORGIA" FOR MATERIAL SPECIFICATIONS.
REFER TO THE LATEST EDITION OF THE "MANUAL FOR EROSION AND SEDIMENT
THEY SHALL BE PROPERLY STAKED FOR DITCH APPLICATIONS.
MATERIAL DERIVED FROM A WELL-DECOMPOSED SOURCE OF ORGANIC MATTER.
BIODEGRADABLE KNITTED MESH MATERIAL CONTAINING A WEED FREE FILLER
A COMPOST FILTER SOCK CHECK DAM IS COMPOSED OF A PHOTODEGRADABLE OR
USED AT THE DOWNSTREAM DISCHARGE POINT.
PAD. PROPER STAKING IS ALSO REQUIRED FOR DITCH…