This is a Purchase Description document detailing the National Institute on Aging's (NIA) requirements for Mass Spectrometry Reagents needed for research on Alzheimer's Disease and Related Dementias. The document specifies four ThermoFisher products: EASY-SPRAY HPLC Column (90 units), Acclaim PepMap HPLC Column (150 units), CAP SNP 11MM BL PE S/T caps (60 packs), and VIAL 0.3ML CLR PP SNP CON INS vials (60 packs).
The deliveries are structured in three phases: base quantity due by July 7, 2025, Option 1 quantity by July 7, 2026, and Option 2 quantity by July 7, 2027, each consisting of approximately one-third of the total quantities. The document provides detailed technical specifications for each product, including column formats, dimensions, pressure ratings, particle sizes, and other critical parameters. All materials must be delivered in immediate usable condition and marked with contract number and contractor name. The products will support the NIA's objective of creating a national resource of isogenic sets of Alzheimer's Disease mutation iPSC lines with foundational phenotypic datasets.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Version 11-30-2016-1 FAR Part 11—Describing Agency Needs
PURCHASE DESCRIPTION
1. Statement of Need and Purpose: The National Institute on Aging (NIA) requires the acquisition of Mass Spectrometry Reagents for mass spectrometry-based proteomics, peptidomics, lipidomics and metabolomics to understand the underlying biology of Alzheimer’s Disease and Related Dementias.
2. Background Information and Objective: The NIA’s objective is to create a national resource of isogenic sets of Alzheimer’s Disease and Related Dementias mutation iPSC lines, complimented by foundational phenotypic datasets from differentiated disease-relevant cells derived from these lines. The NIA anticipates that this resource will substantially accelerate the pace of mechanistic discovery regarding how Alzheimer’s Disease and Related Dementia mutations cause disease.
3. Generic Name of Product: Mass Spectrometry Reagents
4. Purchase Description:
ThermoFisher EASY-SPRAY HPLC Column PART# ES903 (QTY=90) ThermoFisher Acclaim PepMap HPLC Column PART# 164535 (QTY=150) ThermoFisher CAP SNP 11MM BL PE S/T 100/PK PART# 6ARC11ST1 (QTY=60) ThermoFisher VIAL 0.3ML CLR PP SNP CON INS 100/PK PART# 6ERV11-03PPC
(QTY=60)
5. Salient characteristics All deliverables required under this contract shall be packaged, marked and shipped in accordance with Government specifications. At a minimum, all deliverables shall be marked with the contract number and Contractor name. The Contractor shall guarantee that all required materials shall be delivered in immediate usable and acceptable condition.
Vendor must be able to provide these specifications:
ThermoFisher EASY-SPRAY HPLC Column Column Format: Analytical Column, EASY-Spray Diameter: 75 μm Length: 500 mm Max. Pressure: 14500 psi (1000 bar) Particle Size: 2 μm pH: 2 to 8 Pore Size: 100 Å Surface Area: 450 m²/g Temperature: 60°C USP Type: L1 Stationary Phase: C18 Product Line: Easy Spray
Packing Material: Spherical, Fully Porous, Ultrapure Silica Carbon Load: 15% Column Type: Reversed Phase Endcapped Phase: Reversed Phase
ThermoFisher Acclaim PepMap HPLC Column Column Format: Trap Column, NanoViper Diameter: 0.075 mm For Use With: UltiMate 3000 RSLC Nano System Length: 150 mm Max. Pressure: 7250 psi (500 bar) Particle Size: 3 μm pH: 2 to 8 Pore Size: 100 Å Quantity: Pack of 2 Surface Area: 450 m²/g Temperature: 60°C USP Type: L1 Stationary Phase: C18 Product Line: nanoLC Packing Material: Spherical, Fully Porous, Ultrapure Silica Carbon Load: 15% Column Type: Reversed Phase Endcapped Phase: Reversed Phase Material: PEEK Shielded Fused Silica Type: Trap Column Bed Length: 20 mm Unit Size: Pack of 2
ThermoFisher SureSTART™ 11 mm Snap Caps, Level 2 High-throughput Applications Color: Blue Material: Polyethylene Septum: White Silicone/Red PTFE Hardness: 45 Shore Product Line: SureSTART Level 2 Thickness:1 mm Certifications/Compliance: Specification Certified Type: Snap, Level 2 Closure Size:11 mm For Use With (Equipment): 11 mm Snap Vials Unit Size: Pack of 100
ThermoFisher SureSTART™ 2 mL Polypropylene Snap Top Microvials for <2 mL Samples, Level 1 Everyday Analysis Material: Clear Polypropylene Size Opening: 11 mm Volume Residual: 4 μL
Base Style: Insert Vial, Conical Product Line: SureSTART Level 1 Volume Total: 0.3 mL Closure Type: Snap Cap Height: 32 mm Certifications/Compliance: Specification Certified Type: 2 mL Snap Plastic Microvial, Level 1 Marking Spot: No Volume Usable: 0.2 mL For Use With (Equipment):11 mm Snap Caps and Septa Unit Size: Pack of 100
6. Quantity: See Purchase Description above for quantities
7. Delivery Dates:
The following base quantity to be delivered by July 7, 2025 ThermoFisher EASY-SPRAY HPLC Column PART# ES903 (QTY=30) ThermoFisher Acclaim PepMap HPLC Column PART# 164535 (QTY=50) ThermoFisher CAP SNP 11MM BL PE S/T 100/PK PART# 6ARC11ST1 (QTY=20) ThermoFisher VIAL 0.3ML CLR PP SNP CON INS 100/PK PART# 6ERV11-03PPC
(QTY=20)
The following option 1 quantity to be delivered by July 7, 2026 ThermoFisher EASY-SPRAY HPLC Column PART# ES903 (QTY=30) ThermoFisher Acclaim PepMap HPLC Column PART# 164535 (QTY=50) ThermoFisher CAP SNP 11MM BL PE S/T 100/PK PART# 6ARC11ST1 (QTY=20) ThermoFisher VIAL 0.3ML CLR PP SNP CON INS 100/PK PART# 6ERV11-03PPC
(QTY=20)
The following option 2 quantity to be delivered by July 7, 2027 ThermoFisher EASY-SPRAY HPLC Column PART# ES903 (QTY=30) ThermoFisher Acclaim PepMap HPLC Column PART# 164535 (QTY=50) ThermoFisher CAP SNP 11MM BL PE S/T 100/PK PART# 6ARC11ST1 (QTY=20) ThermoFisher VIAL 0.3ML CLR PP SNP CON INS 100/PK PART# 6ERV11-03PPC
(QTY=20)
8. Period of Performance: Not Applicable