SHOCK DATA RECORDER AND ACCELEROMETERS
Solicitation number
MICC-FH-033557
Issued by

About this file

This document is a Purchase Description/Salient Characteristics form for a federal contract announcement (MICC-FH-033557) detailing the procurement of specialized data acquisition (DAQ) equipment. The solicitation includes six primary line items: 36 SLICE6 AIR units with advanced sensing capabilities, 42 six-channel sensor cable assemblies, 84 fifteen-foot sensor extension cables, 84 triaxial piezoresistive accelerometers, 9 DS-4 racks for simultaneous DAQ downloads, and 10 interface device cable kits. Each item has precise technical specifications, including requirements for housing size, shock rating, sampling rates, measurement capabilities, and NIST calibration traceability.

The equipment is designed for high-precision data collection, with specifications mandating features such as a compact 2" x 2" x 2" housing, 500g shock rating, 10,000Hz sample rate, and the ability to measure shock, angular rate, barometric pressure, and GPS positional data. The procurement includes not just the primary equipment but also allows for a 15% initial benchstock of replacement parts for cables, adapters, and accelerometers. The solicitation emphasizes technical capabilities like real-time streaming, time synchronization of up to 4 DAQs, standalone recorder functionality, and comprehensive interfacing options through ethernet and various connectivity modules.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PURCHASE DESCRIPTION/SALIENT CHARACTERISTICS

Announcement Number MICC-FH-033557

Item Description/Salient Characteristics QTY

SLICE6 AIR

Must meet the following minimum specifications:

Housing size equal to or smaller than 2” x 2” x 2” with a shock rating of at least 500g; minimum of 10,000Hz sample rate with piezoresistive accelerometers; programmable sampling rates and synchronization options; has the ability to measure shock, angular rate, barometric pressure, and GPS positional data; ability to time-sync a minimum of 4 DAQs; must be able to function as a standalone recorder; Real-time streaming capability; NIST calibration traceability.

Slice 6 AIR 6 Ch Sensor (51S - MCS-16) Cable Assy (2ft)

Three channel output adapters for piezoresistive accelerometer that connects the DAQ in line item 1 to the Extension Cable in Line Item 3.

Cable on the connector should be 2 feet or less.

One per DAQ plus an initial benchstock of 15% for replacement parts.

3ch Sensor Extension Cable, 15ft

Cable between accelerometer in line item 4 and Adapter in line item 2 that is a minimum of 10 feet and a maximum of 25 feet long for each accelerometer. One per accelerometer plus 15% for initial benchstock for replacement parts.

Triaxial Piezoresistive Accelerometer (7in cable)

Must be a piezoresistive accelerometer; NIST traceability for shock; IP67 rated; accelerometer cable should be 7” or less; excitation voltage range within limits of DAQ in line item 1; thru-hole mounting with ability to change mounting type with adapter; calibratable along with the DAQ from line item 1; maximum size of (.75” x .75” x .75”) Two per DAQ plus 15% initial benchstock for replacement parts.

DS-4 Rack Ability to download a minimum of 4 DAQs in Line Item 1 simultaneously. 9

Interface Device Cable Kit

Any modules required for the DAQ to interface with a computer for programing thru ethernet;

Power supply for bench top work; connectors and cables for IRIG, GPS, and daisy chaining DAQs in Line Item 1 for time synchronization.

One per DS-4 plus one for benchstock for replacment parts.