PUMP PERFORMANCE TEST WORKSHEET.pdf

PDF 114 KB Posted

Attached to
Annual Mobile Fire Emergency Inspection IAW NFPA 1910
Solicitation number
PAN-023661-X2
Issued by

About this file

The document is a Pump Performance Test Worksheet for emergency vehicles, specifically designed to document comprehensive testing of fire department pump systems in accordance with NFPA 1910 standards. The worksheet captures detailed technical specifications and performance metrics including vehicle identification, pump characteristics, environmental conditions, and multiple test scenarios such as capacity tests, overload tests, and pressure control device assessments.

The related federal contract opportunity is a sources sought notice by the Mission and Installation Contracting Command (MICC) at Fort Leonard Wood, Missouri, seeking qualified contractors to perform annual mobile fire emergency vehicle inspections. The requirement involves inspecting seven fire trucks from manufacturers including Pierce, Ferrara, Oshkosh, KME International, Ford, and E-One. The procurement is potentially set aside for small businesses, with a NAICS code of 541990 and a small business size standard of $16.5 million. Interested parties must submit a 10-page capabilities statement by 2 pm CST on 31 March 2025, demonstrating NFPA 1910 certification and capability to perform comprehensive emergency vehicle inspections. The anticipated contract will have one base year and four option years, with a blanket purchase agreement structure.

View the file

Other files

File Type Posted
ANN INSPECTION BUMPER-TO-BUMPER (B2B) WORKSHEET.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PUMP PERFORMANCE TEST

IAW NFPA1910

© 2024 National Fire Protection Association

Emergency vehicle number or designation ___________

Manufacturer __________________________________

Serial no. _____________________________________

Engine make __________________________________

Pump make ___________________________________

Year manufactured _____________________________

Model _______________________________________

Vehicle identification no. _________________________

Model _______________________________________

Model _______________________________________

Pump rated capacity __________________ (gpm) (L/min) at _______________(psi) (kPa)

Speed check taken from _________________________ Ratio to engine ________________________________

Test site location ___________________________________________________________________________________

Tests performed from __ Draft __ Hydrant

Suction hose size _____________________ (in.) (mm) Length _________________________(ft) (m)

At start of tests At end of tests

Atmospheric pressure

Air Temperature

Water temperature

Elevation of test site

Lift

Governed engine speed ___________________________ Actual maximum engine speed ____________________

Verify operation of pump shift indicator __________________________________________________________________

Verify operation of pump engine control interlock at pump operator’s panel _____________________________________

Maximum vacuum attained _________________________ Vacuum drop in 5 minutes ________________________

Time to prime pump ________________________________________________________________________________

Pressure control device test:

Rise while pumping capacity at 150psi ________________________________________________________________

Rise while pumping capacity at 90 psi ________________________________________________________________

Rise while pumping at 50 percent capacity at 250 psi ____________________________________________________

Intake relief valve test results _________________________________________________________________________

Tank to pump water flow test ___________________ (gpm) (L/min)

Gauge accuracy _____________________________ Flowmeter accuracy ___________________________________

Pump Test Results Capacity test Overload test 200 psi test 250 psi test Duration Average nozzle pressure Corrected pressure Gallons per minute Average pump pressure rpm-engine Rpm-pump

Comments

PUMP PERFORMANCE TEST

IAW NFPA1910

© 2024 National Fire Protection Association

20-Minute Capacity Test Layout _____________________________ Nozzle size _______ Position of transfer valve _______________

Pump Intake Pump Discharge

Time

Counter (if used) rpm

Tach

Engine temperature

Oil pressure

Voltage

Automatic Transmission

Temp (if equipped)

Apparatus gauge

Test

Apparatus

Test

Pilot/ flow

5-Minute Overload Test

10-Minute 200 psi Test

10-Minute 200 psi Test

Person conducting the test ___________________________________________________________________________

Representing _____________________________________________________________________________________

Signature _____________________________________________________ Date ___________________________

AHJ representative _____________________________________________ Date ___________________________

File details come from the government source that posted it. Updated .