Public Safety Complex - Preliminary Drawings_Part5.pdf
PDF 17 MB Posted
- Attached to
- REQUEST FOR PROPOSAL (RFP) # 49-26-SKL PPEA Project to Construct a Public Safety Facility
- Solicitation number
- RFP-121372
- Issued by
- Portsmouth City, Virginia
About this file
Portsmouth Public Safety Complex - Preliminary Drawings Summary
This document is a preliminary architectural and engineering drawing set for the Portsmouth Public Safety Complex project being constructed by the City of Portsmouth, Virginia. The multi-building complex includes a Headquarters building, Training/Range facility, and Warehouse structures, with comprehensive mechanical, electrical, and lighting systems designed to support police, fire, and emergency medical services operations. The drawings depict detailed floor plans, HVAC systems with multiple air handling units and variable air volume terminals, electrical distribution, lighting fixture placement, and control systems across first and second floors of the headquarters building and first floors of the training and warehouse facilities. The submittal documents are dated January 16, 2024, and were prepared by Clark Nexsen architecture and engineering firm in Virginia Beach, Virginia, indicating the project was in the design development or construction document phase at that time.
The mechanical systems include multiple air handling units, dedicated outdoor air systems with energy recovery, gas furnaces, DX cooling systems, and Variable Refrigerant Flow (VRF) heat pumps sized for the specific operational demands of police administrative spaces, training facilities, and evidence storage areas. The electrical systems feature comprehensive lighting control incorporating occupancy sensors, daylight harvesting, time-based scheduling, scene controls, and emergency lighting integration across numerous room types including offices, holding cells, interrogation rooms, classrooms, and support spaces. Multiple lighting fixture types are specified with LED technology across various lumen outputs and color temperatures, with controls coordinated to fire alarm systems and building automation systems. The design accommodates specialized functions including a firearms range with dedicated ventilation, evidence storage with specific environmental controls, and secure holding areas with tamper-resistant fixtures, reflecting the complex security and operational requirements of a modern public safety facility.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
W13
W10
W9
W8
W6
W5
W4
W3
W2
W1
WA WB WC WD WE WF WG WH WJ WK
W12
W11
W7
ELEC
120W
TELECOM
119W
I.T.
MONOPOLE
125W
EMS
TRAINING
STORAGE
116W
FIRE
MARSHALL
STORAGE
114W
EMS
DIVISION
STORAGE
115W
DISTRICT
LIEUTENANTS
STORAGE
118W
CIVIL
DISTURBANCE
121W
QUARTERMASTER
STORAGE
127W
VEHICLE
STORAGE
129W
SPECIAL
OPS
STORAGE
128W
SF
VEHICLE
STORAGE
100W
VEHICLE
STORAGE
101W
VEHICLE
STORAGE
103W
VEHICLE
STORAGE
104W
VEHICLE
STORAGE
105W
VEHICLE
STORAGE
130WPROPERTY
EVIDENCE
STORAGE
126W
CORRIDOR
122W
VEHICLE
STORAGE
131W
RESTROOM
123W
RESTROOM
124W
CAPTAIN
109W
LT
108W
LT
107W
LOGISTICS
OFFICES
106W
LOGISTICS
STORAGE
117W
TURN OUT
GEAR
113W
MAINTENCE
AREA
110W
CRAWL
GEAR
STORAGE
112W
SUPPLY
STORAGE
111W
AHU-W-01
14x12
8x8
VAV-W-1-01
V A
V -W
-1 -0 x8
V A
V -W
-1 -0 x1
V A
V -W
-1 -0
8x x1
16x14
V A
V -W
-1 -0 x1
VAV-W-1-07
VAV-W-1-06
14x12 x1
V
A V
-W -1
-0 x1
12x12
16x14 20x18
8x8
MAU-W-01
x1
MAU-W-02
MAU-W-03
GUH-W-01
GUH-W-02
GUH-W-03
GUH-W-04
GUH-W-05 GUH-W-06
GUH-W-07 GUH-W-08
EF-W-01
EF-W-02
EF-W-03
EF-W-04
HP-W-01
VRF-W-101
VRF-W-102
VRF-W-103
M
M M
(TYP.)
(TYP.)
(TYP.)
(TYP.)
M H
2W
M H
2W
1 1
VIRGINIA BEACH, VIRGINIA 23462
4525 MAIN STREET, SUITE 1400
757·455·5800
1 2 3 4 5 6
A
B
C
D
E
SHEET
B
C
D
E
DESIGN:
DRAWN:
REVIEW:
REVISIONSDESIGNER
A
PROFESSIONAL SEAL
NOT F
OR C
ONSTRUCTIO
N
5032 ROUSE DRIVE, SUITE 200
VIRGINIA BEACH, VA 23462-3764
757.490.9264
CIVIL CONSULTANT
C U s e rs
\a m c e lh a n e y \O n e D ri v e
C la rk
N e x s e n \D o c u m e n ts
\1
P o rt s m o u th C o m p le x W a re h o u s e
M a m c e lh a n e y .r v t
/1
/2
:0
:5
A
M
WAREHOUSE FIRST FLOOR PLAN - AREA A
ACM/KM
KM
ACM
CN 1020535% SUBMITTAL DOCUMENTS
JANUARY 16, 2024
PORTSMOUTH PUBLIC SAFETY COMPLEX
CITY OF PORTSMOUTH
3701 WILLETT DR
PORTSMOUTH, VA 23707
MH101W
SCALE: 1/8" = 1'-0"
WAREHOUSE FIRST FLOOR PLAN - AREA A
1 FOR LEGEND AND GENERAL NOTES SEE SHEET M-001.
GRAPHIC SCALE(S)
GENERAL NOTES
KEY NOTES
1/8" = 1' - 0" 0 5' 10' 15' 30'
1 OUTDOOR AIR INTAKE LOUVER. LOUVER MUST BE RATED FOR
HIGH-VELOCITY WIND-DRIVEN RAIN (AMCA-550). REFER TO
ARCHITECTURAL FOR LOUVER SCHEDULE AND DETAILS.
2 EXHAUST AIR DISCHARGE LOUVER. LOUVER MUST BE RATED FOR
HIGH-VELOCITY WIND-DRIVEN RAIN (AMCA-550). REFER TO
ARCHITECTURAL FOR LOUVER SCHEDULE AND DETAILS.
3 FLUE VENT FROM NATURAL GAS FIRED UNIT ROUTED TO ROOF.
TERMINATE FLUE VENT WITH VENT CAP AND PROVIDE ROOF CURB
FOR THE PENETRATION. SIZE, INSTALL, AND TERMINATE IN
ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS.
W10
W9
W8
W6
WK WL WM WN WP WQ WR
W12
W11
W7
VEHICLE
STORAGE
137W
VEHICLE
STORAGE
135W
VEHICLE
STORAGE
136W
VEHICLE
STORAGE
134W
SF
VEHICLE
STORAGE
133W
VEHICLE
STORAGE
132W
20x20
20x20
RAD-W-01 RAD-W-02
30x20
D O
A S
-W -0
28x28
RAD-W-03 RAD-W-04
(TYP.)
M
H
1W M
H
1W
SCALE: 1/8" = 1'-0"
WAREHOUSE FIRST FLOOR PLAN - AREA B
GRAPHIC SCALE(S)
GENERAL NOTES
KEY NOTES
1/8" = 1' - 0" 0 5' 10' 15' 30'
VIRGINIA BEACH, VIRGINIA 23462
4525 MAIN STREET, SUITE 1400
757·455·5800
1 2 3 4 5 6
A
B
C
D
E
SHEET
B
C
D
E
DESIGN:
DRAWN:
REVIEW:
REVISIONSDESIGNER
A
PROFESSIONAL SEAL
NOT F
OR C
ONSTRUCTIO
N
5032 ROUSE DRIVE, SUITE 200
VIRGINIA BEACH, VA 23462-3764
757.490.9264
CIVIL CONSULTANT
C U s e rs
\a m c e lh a n e y \O n e D ri v e
C la rk
N e x s e n \D o c u m e n ts
\1
P o rt s m o u th C o m p le x W a re h o u s e
M a m c e lh a n e y .r v t
/1
/2
:0
:0
A
M
WAREHOUSE FIRST FLOOR PLAN - AREA B
ACM/KM
KM
ACM
CN 1020535% SUBMITTAL DOCUMENTS
JANUARY 16, 2024
PORTSMOUTH PUBLIC SAFETY COMPLEX
CITY OF PORTSMOUTH
3701 WILLETT DR
PORTSMOUTH, VA 23707
MH102W
1 FOR LEGEND AND GENERAL NOTES SEE SHEET M-001.
1 FLUE VENT FROM NATURAL GAS FIRED UNIT ROUTED TO ROOF.
TERMINATE FLUE VENT WITH VENT CAP AND PROVIDE ROOF CURB
FOR THE PENETRATION. SIZE, INSTALL, AND TERMINATE IN
ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS.
VIRGINIA BEACH, VIRGINIA 23462
4525 MAIN STREET, SUITE 1400
757·455·5800
1 2 3 4 5 6
A
B
C
D
E
SHEET
B
C
D
E
DESIGN:
DRAWN:
REVIEW:
REVISIONSDESIGNER
A
PROFESSIONAL SEAL
NOT F
OR C
ONSTRUCTIO
N
5032 ROUSE DRIVE, SUITE 200
VIRGINIA BEACH, VA 23462-3764
757.490.9264
CIVIL CONSULTANT
C U s e rs
\a m c e lh a n e y \O n e D ri v e
C la rk
N e x s e n \D o c u m e n ts
\1
P o rt s m o u th C o m p le x W a re h o u s e
M a m c e lh a n e y .r v t
/1
/2
:0
:0
A
M
WAREHOUSE SCHEDULES
ACM/KM
KM
ACM
CN 1020535% SUBMITTAL DOCUMENTS
JANUARY 16, 2024
PORTSMOUTH PUBLIC SAFETY COMPLEX
CITY OF PORTSMOUTH
3701 WILLETT DR
PORTSMOUTH, VA 23707
M-601W
9. ELECTRIC REHEAT WITH MODULATING SCR CONTROLS.
8. DOOR INTERLOCKING DISCONNECT SWITCH.
7. POWER FUSE.
6. MAGNETIC DISCONNECTING CONTACTORS.
5. INTEGRAL STEPDOWN TRANSFORMER FOR CONTROL POWER. COORDINATE VOLTAGE WITH ELECTRICAL CONTRACTOR.
4. 1"-THICK MATTE-FACED FIBERGLASS INSULATION.
3. MINIMUM 22 GAUGE GALVANIZED CONSTRUCTION.
2. VAV BOXES SHALL BE PRESSURE INDEPENDENT WITH FACTORY MOUNTED DDC CONTROLLERS.
1. BASIS OF DESIGN: TITUS MODEL DESV.
NOTES:
VAV-W-108 10 885 270 580 6.4 55.0 90.0 0.2
VAV-W-107 10 625 190 370 4.0 55.0 90.0 0.2
VAV-W-106 10 880 265 600 6.6 55.0 90.0 0.2
VAV-W-105 12 1,110 335 650 7.2 55.0 90.0 0.2
VAV-W-104 6 180 55 80 0.9 55.0 90.0 0.2
VAV-W-103 8 545 165 330 3.6 55.0 90.0 0.2
VAV-W-102 8 330 100 190 2.1 55.0 90.0 0.2
VAV-W-101 10 1,005 305 730 8.1 55.0 90.0 0.2
ENT LVG
MAX. MIN. HTG
MIN.
CAPACITY
(KW)
AIR TEMP (°F) MAX.
APD
(IN. W.G.)
MARK
MIN.
INLET
DIAMETER
(IN)
MIN.
INLET
STATIC
(IN. W.G.)
MAX.
RADIATED
NOISE
(NC)
MAX.
DISCHARGE
NOISE
(NC)
VOL. REG. (CFM) HEATING COIL
ELECTRIC VARIABLE AIR VOLUME TERMINAL UNIT SCHEDULE
7. PROVIDE WITH MANUFACTURER SUPPLIED MOUNTING BRACKET. SUPPORT FROM STRUCTURE ABOVE WITH VIBRATION ISOLATOR.
6. MODULATING DIRECT GAS-FIRED FURNACE.
5. DIRECT DRIVE PLENUM FAN WITH VFD OR ECM MOTOR FOR BALANCING PURPOSE.
3. DISCONNECT SWITCH.
2. UNIT-MOUNTED MICROPROCESSOR CONTROLLER WITH BACNET COMMUNICATION INTERFACE.
1. SINGLE POINT POWER CONNECTION.
NOTES:
MAU-W-03 VEHICLE STORAGE 3,740 0.5 2 165.0 22.5 55.0 92.0 8 0.5 GREENHECK DGX
MAU-W-02 VEHICLE STORAGE 3,740 0.5 2 165.0 22.5 55.0 92.0 8 0.5 GREENHECK DGX
MAU-W-01 VEHICLE STORAGE 2,335 0.5 1 101.0 22.5 55.0 92.0 8 0.5 GREENHECK DGX
ENT. DB LVG. DB
MAX
AIRFLOW
(CFM)
ESP
(IN. W.G.)
MAX
HP
MIN. OUTPUT
CAPACITY
(MBH)
AIR TEMP (°F) MIN.
EFFICIENCY
MERV
PD
(IN. WG.)
MANUFACTURER MODEL
MARK SERVICE
SUPPLY FAN GAS FURNACE FILTER
WEIGHT
(LBS)
BASIS OF DESIGN
HEATING AND VENTILATION UNIT SCHEDULE
15. MANUFACTURER'S CURB.
7. HIGH-EFFICIENCY, VARIABLE SPEED SCROLL COMPRESSORS. 14. STAINLESS STEEL DRAIN PAN WITH CONDENSATE OVERFLOW SWITCH.
6. DUAL ENTHALYPY ECONOMIZER WITH FULLY MODULATING LOW-LEAK DAMPERS AND AIRFLOW MEASUREMENT. 13. 2-STAGE INDIRECT-FIRED GAS FURNACE WITH STAINLESS STEEL HEAT EXCHANGER.
5. AIR-COOLED CONDENSING UNIT SECTION SELECTED FOR 95°F AMBIENT TEMPERATURE. 12. LOW-AMBIENT COOLING.
4. SINGLE POINT ELECTRICAL CONNECTION WITH NON-FUSED THROUGH-THE-DOOR DISCONNECT SWITCH. 11. UNIT-POWERED CONVENIENCE RECEPTACLE.
3. UNIT-MOUNTED MICROPROCESSOR CONTROLLER WITH BACNET COMMUNICATION INTERFACE. 10. ALUMINIMUM MICRO-CHANNEL CONDENSER COILS.
2. DOUBLE-WALL, THERMALLY BROKEN CONSTRUCTION WITH HINGED, TOOL-FREE ACCESS DOORS. 9. DIRECT DRIVE PLENUM SUPPLY FANS WITH PREMIUM EFFICIENCY MOTORS AND VFDS.
1. ESP DOES NOT INCLUDE PRESSURE DROP OF FILTERS, COILS, OR OTHER INTERNAL UNIT COMPONENTS. 8. CORROSION RESISTANT COATING ON CONDENSER AND EVAPORATOR COILS.
NOTES:
AHU-W-01 WAREHOUSE VAV 5,300 1,385 3,530 1.75 10 1,750 4,500 N/A N/A 232.7 161.4 80.7 66.8 53.3 52.7 10.8 14.0 N/A N/A N/A 60.0 31.0 60.0 80 8 0.5 13 1.0 2250 JOHNSON CONTROLS AD
TOTAL SENSIBLE ENT. DB ENT. WB LVG. DB LVG. WB EER IEER ENT. LVG. ENT. DB LVG. DB MERV
PD
(IN. WG.)
MERV
PD
(IN. WG.)
MAX
AIRFLOW
(CFM)
MIN
AIRFLOW
(CFM)
HEATING
AIRFLOW
(CFM)
ESP
(IN. W.G.)
MAX
HP
MAX
AIRLOW
(CFM)
ESP
(IN. W.G.)
MAX
HP
CAPACITY (MBH) AIR TEMP (°F) MIN. EFFICIENCIES
CAPACITY
(MBH)
AIR TEMP (°F)
MIN. OUTPUT
CAPACITY
(MBH)
AIR TEMP (°F)
MIN.
EFFICIENCY
PRE-FILTER FILTER
MANUFACTURER MODEL
MARK SERVICE CONTROL
SUPPLY FAN
OUTDOOR
AIRFLOW (CFM)
EXHAUST FAN DX COOLING HOT GAS REHEAT GAS FURNACE FILTERS
WEIGHT
(LBS)
BASIS OF DESIGN
AIR HANDLING UNIT SCHEDULE
15. MANUFACTURER'S CURB.
7. HIGH-EFFICIENCY, VARIABLE SPEED SCROLL COMPRESSORS. 14. STAINLESS STEEL DRAIN PAN WITH CONDENSATE OVERFLOW SWITCH.
6. PREMIUM EFFICIENCY MOTORS AND VFDS ON SUPPLY AND EXHAUST FANS. 13. 2-STAGE INDIRECT-FIRED GAS FURNACE WITH STAINLESS STEEL HEAT EXCHANGER.
5. AIR-COOLED CONDENSING UNIT SECTION SELECTED FOR 95°F AMBIENT TEMPERATURE. 12. LOW-AMBIENT COOLING.
4. SINGLE POINT ELECTRICAL CONNECTION WITH NON-FUSED THROUGH-THE-DOOR DISCONNECT SWITCH. 11. UNIT-POWERED CONVENIENCE RECEPTACLE.
3. UNIT-MOUNTED MICROPROCESSOR CONTROLLER WITH BACNET COMMUNICATION INTERFACE. 10. ALUMINIMUM MICRO-CHANNEL CONDENSER COILS.
2. DOUBLE-WALL, THERMALLY BROKEN CONSTRUCTION WITH HINGED, TOOL-FREE ACCESS DOORS. 9. DIRECT DRIVE PLENUM SUPPLY FANS WITH PREMIUM EFFICIENCY MOTORS AND VFDS.
1. ESP DOES NOT INCLUDE PRESSURE DROP OF FILTERS, COILS, OR OTHER INTERNAL UNIT COMPONENTS. 8. CORROSION RESISTANT COATING ON CONDENSER AND EVAPORATOR COILS.
NOTES:
DOAS-W-01 WAREHOUSE CAV 5,300 5,300 5,300 1.5 5 5,300 4,825 0.75 5 246.6 158.1 81.9 69.1 53.6 53.5 12.3 14.8 102.0 53.3 72.0 175.0 55.1 85.0 4,325 AAON RNA
TOTAL SENSIBLE ENT. DB ENT. WB LVG. DB LVG. WB EER IEER ENT. LVG. ENT. DB LVG. DB
MAX
AIRFLOW
(CFM)
MIN
AIRFLOW
(CFM)
HEATING
AIRFLOW
(CFM)
ESP
(IN. W.G.)
MAX
HP
MAX
AIRLOW
(CFM)
ESP
(IN. W.G.)
MAX
HP
CAPACITY (MBH) AIR TEMP (°F) MIN. EFFICIENCIES
CAPACITY
(MBH)
AIR TEMP (°F) MIN. OUTPUT
CAPACITY
(MBH)
AIR TEMP (°F) MIN.
EFFICIENCY
MANUFACTURER MODEL
MARK SERVICE CONTROL
SUPPLY FAN
OUTDOOR
AIRFLOW
(CFM)
EXHAUST FAN DX COOLING HOT GAS REHEAT GAS FURNACE
WEIGHT
(LBS)
BASIS OF DESIGN
ENERGY RECOVERY DEDICATED OUTDOOR AIR UNIT SCHEDULE
DOAS-W-01 95.0 77.5 81.9 69.1 22.5 17.4 53.0 42.3 0.7 76.0 62.5 90.2 72.7 68.0 54.0 33.5 30.3 0.7 0.2 64.2 69.4 8 0.5 13 1.0 8 0.5
ENT. DB ENT. WB LVG. DB LVG. WB ENT. DB ENT. WB LVG. DB LVG. WB ENT. DB ENT. WB LVG. DB LVG. WB ENT. DB ENT. WB LVG. DB LVG. WB MERV
PD
(IN. WG.)
MERV
PD
(IN. WG.)
MERV
PD
(IN. WG.)
SUMMER TEMPERATURES (°F) WINTER TEMPERATURES (°F)
MAX.
APD
(IN. W.G.)
SUMMER TEMPERATURES (°F) WINTER TEMPERATURES (°F)
MAX.
APD
(IN. W.G.)
SUMMER WINTER
PRE-FILTER FILTER FILTER
OUTDOOR AIRSTREAM EXHAUST AIRSTREAM
MAX.
WHEEL
HP
MIN. EFFECTIVENESS (%) OUTDOOR AIRSTREAM EXHAUST AIRSTREAM
MARK
ENERGY RECOVERY FILTERS
ENERGY RECOVERY DEDICATED OUTDOOR AIR UNIT SCHEDULE - TOTAL ENTHALPY ENERGY RECOVERY WHEEL
4. PROVIDE WITH ECM, INTEGRAL PROTECTION & DISCONNECT SWITCH, BACKDRAFT DAMPER.
3. PROVIDE WITH ACOUSTICALLY INSULATED HOUSING & BUILT IN THERMAL OVERLOAD PROTECTION.
2. PROVIDE WITH MANUFACTURER SUPPLIED MOUNTING BRACKET. SUPPORT FROM STRUCTURE ABOVE WITH VIBRATION ISOLATOR
1. PROVIDE WITH VFD, INTEGRAL PROTECTION, UNIT MOUNTED LOW VOLTAGE THERMOSTAT & DISCONNECT SWITCH, BACKDRAFT DAMPER.
NOTES:
EF-W-04 IN-LINE 150 0.30 DIRECT 1,573 0.07 4.6 GREENHECK SQ 2,4
EF-W-03 AXIAL IN-LINE 11,445 0.50 DIRECT 1,687 5.00 30.0 GREENHECK AX 1,2,3
EF-W-02 AXIAL IN-LINE 11,445 0.50 DIRECT 1,687 5.00 30.0 GREENHECK AX 1,2,3
EF-W-01 AXIAL IN-LINE 7,155 0.50 DIRECT 1,752 1.50 22.0 GREENHECK AX 1,2,3
MANUFACTURER MODEL
MARK SERVICE TYPE AIRFLOW (CFM)
ESP
(IN. W.G.)
DRIVE
MAX
RPM
MAX
HP
MAX
SONES
BASIS OF DESIGN
NOTES
FAN SCHEDULE
757·455·5800
1 2 3 4 5 6
A
B
C
D
E
SHEET
B
C
D
E
DESIGN:
DRAWN:
REVIEW:
REVISIONSDESIGNER
A
PROFESSIONAL SEAL
NOT F
OR C
ONSTRUCTIO
N
5032 ROUSE DRIVE, SUITE 200
VIRGINIA BEACH, VA 23462-3764
757.490.9264
CIVIL CONSULTANT
C U s e rs
\a m c e lh a n e y \O n e D ri v e
C la rk
N e x s e n \D o c u m e n ts
\1
P o rt s m o u th C o m p le x W a re h o u s e
M a m c e lh a n e y .r v t
/1
/2
:0
:0
A
M
WAREHOUSE SCHEDULES
ACM/KM
KM
ACM
CN 1020535% SUBMITTAL DOCUMENTS
JANUARY 16, 2024
PORTSMOUTH PUBLIC SAFETY COMPLEX
CITY OF PORTSMOUTH
3701 WILLETT DR
PORTSMOUTH, VA 23707
M-602W
8. MINIMUM CLEARANCE FROM COMBUSTIBLE MATERIAL SHALL AS RECOMMENDED BY MANUFACTURER.
7. COORDINATE ACTUAL MOUNTING HEIGHT WITH LIGHTS, DUCTWORK ETC.
6. SUSPEND FROM STRUCTURE IN ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS.
5. PROVIDE WITH MANUFACTURER SUPPLIED MOUNTING BRACKET.
4. PROVIDE MANUFACTURER'S STANDARD WITH VENT KIT, BURNER AND CONTROLS
3. PROVIDE WITH INTEGRAL DISCONNECT AND TAMPERPROOF THERMOSTAT.
2. MOUNTING HEIGHT 18' AFF.
1. BASIS OF DESIGN: MANUFACTURER - SRP; MODEL - TX.
NOTES:
RAD-W-04 60 40 1/2" 4" 4" VENTED TWO STAGE
RAD-W-03 60 40 1/2" 4" 4" VENTED TWO STAGE
RAD-W-02 60 40 1/2" 4" 4" VENTED TWO STAGE
RAD-W-01 60 40 1/2" 4" 4" VENTED TWO STAGE
GAS (IN) INTAKE (IN) VENT (IN) TYPE
CAPACITY
CONTROL
MARK LOCATION
GAS
INPUT (MBH)
NOMINAL
LENGTH (FT)
CONNECTION SIZES BURNER
GAS-FIRED INFRARED RADIANT HEATER SCHEDULE
8. MINIMUM CLEARANCE FROM COMBUSTIBLE MATERIAL SHALL AS RECOMMENDED BY MANUFACTURER.
7. COORDINATE ACTUAL MOUNTING HEIGHT WITH LIGHTS, DUCTWORK ETC.
6. SUSPEND FROM STRUCTURE IN ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS.
5. PROVIDE WITH MANUFACTURER SUPPLIED MOUNTING BRACKET.
4. PROVIDE MANUFACTURER'S STANDARD WITH VENT KIT, BURNER AND CONTROLS
3. PROVIDE WITH INTEGRAL DISCONNECT AND TAMPERPROOF THERMOSTAT.
2. MOUNTING HEIGHT 18' AFF.
1. BASIS OF DESIGN: MANUFACTURER - SRP; MODEL - TX.
NOTES:
GUH-W-08 30.0 24.6 82.0 55.0 VENTED SINGLE STAGE
GUH-W-07 30.0 24.6 82.0 55.0 VENTED SINGLE STAGE
GUH-W-06 30.0 24.6 82.0 55.0 VENTED SINGLE STAGE
GUH-W-05 30.0 24.6 82.0 55.0 VENTED SINGLE STAGE
GUH-W-04 30.0 24.6 82.0 55.0 VENTED SINGLE STAGE
GUH-W-03 30.0 24.6 82.0 55.0 VENTED SINGLE STAGE
GUH-W-02 30.0 24.6 82.0 55.0 VENTED SINGLE STAGE
GUH-W-01 30.0 24.6 82.0 55.0 VENTED SINGLE STAGE
TYPE CONTROL CAPACITY
MARK SERVICE
GAS
INPUT (MBH)
MIN. OUTPUT
(MBH)
MIN.
EFFICIENCY (%)
ENT
AIR TEMP.
(°F)
BURNER
GAS-FIRED UNIT HEATER SCHEDULE
2. AIR COOLED CONDENSING UNITS RATED FOR COOLING AT 95°F DB AMBIENT & HEATING AT 20°F DB AMBIENT.
1. DISCONNECT SWITCH
NOTES:
HP-W-01 OUTSIDE HEAT PUMP 35.6 35.0 12.0 N/A DAIKIN RXTQ36TAVJ9
EER IEER
COOLING MBH HEATING MBH
MIN. EFFICIENCIES
MANUFACTURER MODEL
MARK LOCATION TYPE
NOMINAL CAPACITY BASIS OF DESIGN
VRF HEAT PUMP SCHEDULE
3. PROVIDE WITH CONDENSATE PUMP ACCESSORY. PUMP SHALL BE POWERED FROM THE INDOOR UNIT AND MOUNTED WITHIN THE UNIT CABINET.
2. PROVIDE MANUFACTURER'S STANDARD FILTER AND WALL-MOUNTED THERMOSTAT.
1. DISCONNECT SWITCH.
NOTES:
VRF-W-103 WALL-MOUNT 290 N/A 11.8 8.7 80.0 67.0 HP-W-01 DAIKIN FXAQ12PVJU
VRF-W-102 WALL-MOUNT 290 N/A 11.8 8.7 80.0 67.0 HP-W-01 DAIKIN FXAQ12PVJU
VRF-W-101 WALL-MOUNT 290 N/A 11.8 8.7 80.0 67.0 HP-W-01 DAIKIN FXAQ12PVJU
TOTAL SENSIBLE DB WB
SUPPLY FAN
ESP
IN W.G.
MAX.
HP
MIN. CAPACITY (MBH) ENTERING AIR (°F)
MANUFACTURER MODEL
MARK LOCATION TYPE
SUPPLY FAN COOLING
OUTDOOR UNIT
BASIS OF DESIGN
VRF INDOOR UNIT SCHEDULE
MECHANICAL
106T
HOUSEKEEPING
102T
STORAGE
103T
RUBBER
BULLET
TRAP
105T
10 LANE
RANGE
104T
DECONTAMINATION
101T
DECON
107T
BATHROOM
108T
BATHROOM
109T
PT
STORAGE
109U
REU-1
RVU-1
REU-1
CU-1
VIRGINIA BEACH, VIRGINIA 23462
4525 MAIN STREET, SUITE 1400
757·455·5800
1 2 3 4 5 6
A
B
C
D
E
SHEET
B
C
D
E
DESIGN:
DRAWN:
REVIEW:
REVISIONSDESIGNER
A
PROFESSIONAL SEAL
NOT F
OR C
ONSTRUCTIO
N
5032 ROUSE DRIVE, SUITE 200
VIRGINIA BEACH, VA 23462-3764
757.490.9264
CIVIL CONSULTANT
C U s e rs \a m c e lh a n e y \O n e D ri v e
C la rk
N e x s e n
\D o c u m e n ts \1
P o rt s m o u th C o m p le x R a n g e
M a m c e lh a n e y .r v t
/1
/2
:5
:5
A
M
TRAINING FIRST FLOOR DUCTWORK PLAN
WNW
WNW
ACM
CN 1020535% SUBMITTAL DOCUMENTS
JANUARY 16, 2024
PORTSMOUTH PUBLIC SAFETY COMPLEX
CITY OF PORTSMOUTH
3701 WILLETT DR
PORTSMOUTH, VA 23707
MH101T
GRAPHIC SCALE(S)
# KEY NOTES
GENERAL NOTES
1/8" = 1' - 0" 0 5' 10' 15' 30'
1 FOR LEGEND AND GENERAL NOTES SEE SHEET M-001.
SCALE: 1/8" = 1'-0"
TRAINING FIRST FLOOR DUCTWORK PLAN
1 RANGE VENTILATION UNIT. ASSOCIATED REMOTE CONDENSING UNIT
(CU-1) LOCATED OUTSIDE ON GRADE.
757·455·5800
1 2 3 4 5 6
A
B
C
D
E
SHEET
B
C
D
E
DESIGN:
DRAWN:
REVIEW:
REVISIONSDESIGNER
A
PROFESSIONAL SEAL
NOT F
OR C
ONSTRUCTIO
N
5032 ROUSE DRIVE, SUITE 200
VIRGINIA BEACH, VA 23462-3764
757.490.9264
CIVIL CONSULTANT
C U s e rs \a m c e lh a n e y \O n e D ri v e
C la rk
N e x s e n
\D o c u m e n ts \1
P o rt s m o u th C o m p le x R a n g e
M a m c e lh a n e y .r v t
/1
/2
:5
:5
A
M
TRAINING SCHEDULES
WNW
WNW
ACM
CN 1020535% SUBMITTAL DOCUMENTS
JANUARY 16, 2024
PORTSMOUTH PUBLIC SAFETY COMPLEX
CITY OF PORTSMOUTH
3701 WILLETT DR
PORTSMOUTH, VA 23707
M-601T
5. TYPICAL OF 4 FANS
4. EXTERNAL STATIC PRESSURE (ESP) INCLUDE PRESSURE DROP OF DIRTY FILTERS, BUT NOT UNIT.
3. INTERNAL FAN VIBRATION ISOLATION
2. PREMIUM EFFICIENCY, INVERTER DUTY RATED FAN MOTOR.
1. PROVIDE WITH FACTORY INSTALLED VARIABLE FREQUENCY DRIVE. PROVIDE INTEGRAL DISCONNECT SWITCH.
NOTES:
REU-1 40,700 AF 2675 7 II 25 1800 X XTI MERV 8 91.7 500 MERV-14 91.7 500 MERV-17 85.9 500 1;2;3;4;5;
TYPE RPM
E .S
.P . I
N . W
.G
C
LA
S S
TOTAL
MOTOR H.P.
RPM
Y O
R K
D A
IK
IN
G R
E E
N H
E C
K
QUANTITY () &
SIZES (IN.)
EFFICIENCY
FACE AREA
(SQFT)
DESIGN FACE
VELOCITY
(FPM)
PRESSURE DROP
CLEN/DIRTY (IN.
W.G.)
QUANTITY () &
SIZES (IN.)
EFFICIENCY
FACE AREA
(SQFT)
DESIGN FACE
VELOCITY
(FPM)
PRESSURE DROP
CLEN/DIRTY (IN.
W.G.)
QUANTITY () &
SIZES (IN.)
EFFICIENCY
FACE AREA
(SQFT)
DESIGN FACE
VELOCITY
(FPM)
PRESSURE DROP
CLEN/DIRTY (IN.
W.G.)
MARK C.F.M.
MOTOR MNFR
MODEL NO.
PREFILTER FILTER FINAL FILTER
MAX OPER.
WEIGHT (LBS)
NOTES
RANGE EXHAUST / FILTRATION UNIT SCHEDULE
2. PROVIDE UV LIGHTS & ECONOMIZER SECTION. PROVIDE INTEGRAL DISCONNECT SWITCH AND DUPLEX MAINTENANCE RECEPTACLE.
1. PROPANE HEATING SECTION
NOTES:
RVU-1 X X XTI 18,500 18,500 9,250 3 AF 3500 3 II 15 3600 8 18,500 18,500 3 AF 3550 2 II 10 3600 X 794 45.3 85 932 0.0 85 1;2;
S
IN
G
LE
Z O
N E
M U
LT
I Z
O N
E
V A
V
C U
S T
O M
M O
D U
LE
R
Y O
R K
JC
I
D A
IK
IN MAX.
C.F.M.
MIN. C.F.M.
(Occ)
MIN. O.A.
C.F.M.
# OF FANS TYPE RPM
E X
T E
R N
IA
L
IN
. W
.G
C
LA
S S
TOTAL
MOTOR H.P.
RPM
MIN FACE
AREA SF
MERV RATING
MAX.
C.F.M.
MIN. C.F.M.
(Occ)
# OF FANS TYPE RPM
E X
T E
R N
IA
L
IN
. W
.G
C
LA
S S
TOTAL
MOTOR H.P.
RPM
R E
-H E
A T
TOTAL MBH
HTG
MIN. FACE
AREA SF.
E.A.T. F L.A.T. F
G A
S S
U P
P
LY
P R
E S
U R
E
IN
W
.G
IN
P
U T
C A
P A
C
IT
Y
M B
H
TOTAL MBH
HTG
MIN. FACE
AREA SF.
E.A.T. F L.A.T. F
G A
S S
U P
P
LY
P R
E S
U R
E
IN
W
.G
IN
P
U T
C A
P A
C
IT
Y
M B
H
Mark
TYPE MNFR
MODEL
SERIES
SUPPLY FAN
MOTOR
SUPPLY - PREFILTER RETURN FAN
GAS FURNANCE COOLING COIL
MAX. OPER.
WEIGHT (LBS)
NOTES
RANGE VENTILATION UNITS SCHEDULE
SB
E
F
RL
M
P
A a
OS
K
OS
OS
OS
DL
P
PS
DOS
RL
F
SPD
EPO
M
LV LV
LE LE
PP
SF
AV
TV
PANELBOARD - 208Y/120V, UON. DASHED AREA INDICATES CLEARANCE ZONE.
PANELBOARD - 480Y/277V, UON. DASHED AREA INDICATES CLEARANCE ZONE.
DRY-TYPE TRANSFORMER. SOLID HATCH INDICATES FRONT. 'T1' INDICATES
NAME. OUTLINE INDICATES MOUNTED ON CONCRETE PAD. REFER TO DRY-
TYPE TRANSFORMER SCHEDULE ON SHEET ___.
SWITCHBOARD/SWITCHGEAR SECTION, SIZE AND VOLTAGE AS INDICATED.
AUTOMATIC TRANSFER SWITCH, SEE RISER DIAGRAM FOR
CHARACTERISTICS
DISTRIBUTION
T1
1 N L P A 1
BUILDING AREA WHERE PANEL IS LOCATED (AREA A, B, C, D)
INDIVIDUAL PANELBOARD NUMBER
VOLTAGE SYSTEM (H=480Y/277V, L=208Y/120V, T=TRANSFORMER)
POWER SYSTEM (N=NORMAL, E=EMERGENCY (NEC 700), L=LEGALLY REQUIRED
(NEC 701), S=OPTIONAL STANDBY(NEC 702), C=CRITICAL OPERATIONS (NEC 708)
FLOOR LEVEL
LOAD TYPE (D=DISTRIBUTION, L=LIGHTING, M=MECHANICAL, T=IT, P=ELECTRICAL)
[EXAMPLE] PANELBOARD NAMING CONVENTION
MDP
T1
ATS
EQUIPMENT MARK - SEE EQUIPMENT CONNECTION SCHEDULE SHEET ____.
EQUIPMENT CONNECTION AS NOTED. [FOR MECHANICAL/PLUMBING
EQUIPMENT: DISCONNECT SWITCHES, STARTERS, ASD'S AND OTHER
REQUIRED COMPONENTS FOR THE OPERATION OF THE EQUIPMENT MUST BE
FURNISHED BY THE MECHANICAL/PLUMBING CONTRACTOR. PROVIDE
CONDUIT AND WIRING FROM THE POWER SOURCE TO THE DISCONNECT
SWITCH, FROM THE DISCONNECT SWITCH TO THE STARTER/ASD, AND FROM
THE STARTER/ASD TO THE FINAL EQUIPMENT CONNECTION. SEE DIVISION
BREAKDOWN DETAIL _______].
JUNCTION BOX
DISCONNECT SWITCH. REFER TO EQUIPMENT CONNECTION SCHEDULE
SHEET _____ FOR SIZE AND TYPE. OTHERWISE, PROVIDE 600V IN NEMA 1
ENCLOSURE UON. 3P = NO. OF POLES, 60 = SWITCH RATING, 40 = FUSE
RATING (NF INDICATES NON-FUSIBLE) (SEE LEGEND NOTE 5).
ENCLOSED CIRCUIT BREAKER [240V] [480V] [600V] IN NEMA 1 ENCLOSURE, [10]
[14] MINIMUM KAIC UON. 3P = NO. OF POLES, 60 = FRAME RATING, 40 = TRIP
RATING (SEE LEGEND NOTE 5).
DISCONNECT SWITCH PROVIDED INTEGRAL WITH EQUIPMENT
MAGNETIC MOTOR CONTROLLER (CONTROLLER FURNISHED WITH
EQUIPMENT).
MANUAL MOTOR CONTROLLER (CONTROLLER FURNISHED WITH EQUIPMENT).
LINE VOLTAGE THERMOSTAT CONNECTION (THERMOSTAT FURNISHED WITH
EQUIPMENT).
ADJUSTABLE SPEED DRIVE (FORMERLY VARIABLE FREQUENCY DRIVE (VFD))
(DRIVE FURNISHED WITH EQUIPMENT).
FAN CONTROL SWITCH (FURNISHED WITH EQUIPMENT). MOUNT 46" AFF UON.
RAISE/LOWER SWITCH (FURNISHED WITH EQUIPMENT). MOUNT 46" AFF UON.
MOTOR RATED SWITCH. MOUNT 46" AFF UON.
SWITCH WITH PILOT LIGHT. MOUNT 46" AFF UON.
PUSH BUTTON. TYPE AND MOUNTING HEIGHT INDICATED ON PLANS
CONTROL PANEL AS INDICATED (ATS, GENERATOR ANNUNCIATOR, ETC)
EQUIPMENT CONNECTIONS
J
3P 60
C 3P 60
T
ASD
AHU-1
A
ROOM LIGHTING CONTROL TYPE TAG. REFER TO LIGHTING CONTROL
NARRATIVE SCHEDULE ON SHEET ______.
LIGHTING FIXTURE TAGS.
• 'A' UPPERCASE LETTER INDICATES LIGHTING FIXTURE TYPE, SEE
LIGHTING FIXTURE SCHEDULE ON SHEET ___.
• 'a' LOWERCASE LETTER INDICATES LIGHTING CONTROL ZONE.
• 'z1' INDICATES DAYLIGHT HARVESTING ZONE (1 OR 2).
• +9'-6" INDICATES MOUNTING HEIGHT AFF.
1. PENDANT MOUNTING HEIGHT TO BOTTOM OF FIXTURE.
2. WALL MOUNTING HEIGHT TO CENTER OF FIXTURE.
LIGHTING FIXTURE ( INDICATES BRACKET, WALL MOUNTED FIXTURES).
EMERGENCY LIGHTING FIXTURE ( INDICATES BRACKET, WALL MOUNTED
FIXTURES). (SEE LEGEND NOTE 4).
EXIT LIGHTING FIXTURE TYPE ___, UON. ARROW, WHEN USED, INDICATES
DIRECTION ( INDICATES BRACKET, WALL MOUNTED FIXTURES). FILLED IN
QUADRANT(S) OF SYMBOL INDICATES NUMBER AND ORIENTATION OF
ILLUMINATED FACES (SEE LEGEND NOTE 4).
EMERGENCY BATTERY POWERED LIGHTING UNIT. NUMBER OF HEADS AS
INDICATED. TYPE ___ UON (SEE LEGEND NOTE 4).
REMOTE EMERGENCY LIGHTING HEAD. ONE OR TWO HEADS AS INDICATED.
FIXTURE TYPE ___ UON
LOW VOLTAGE ON/OFF SWITCH. MOUNT 46" AFF UON.
LOW VOLTAGE KEYPAD/SWITCH W/ OR W/O DIMMING. MOUNT 46" AFF UON.
SEE SHEET ___ FOR SWITCH TYPE CONFIGURATIONS.
• 'A' UPPERCASE SUBSCRIPT LETTER INDICATES SWITCH TYPE.
• 'a' LOWERCASE SUBSCRIPT LETTER INDICATES LIGHTING CONTROL ZONE.
LOW VOLTAGE DUAL OCCUPANCY SENSOR CONTROLLER SWITCH
(ULTRASONIC AND INFRARED). MOUNT 46" AFF UON.
LOW VOLTAGE DUAL OCCUPANCY SENSOR CONTROLLER SWITCH WITH
DIMMING (ULTRASONIC AND INFRARED). MOUNT 46" AFF UON.
LOW VOLTAGE KEY OPERATED SWITCH. MOUNT 46" AFF UON.
LINE VOLTAGE DUAL OCCUPANCY SENSOR CONTROLLER SWITCH
(ULTRASONIC AND INFRARED), 20 A, 120-277 V. MOUNT 46" AFF UON.
LINE VOLTAGE SINGLE POLE SWITCH, 20A, 120/277V. MOUNT 46" AFF UON.
LINE VOLTAGE THREE-WAY SWITCH, 20A, 120/277V. MOUNT 46" AFF UON.
LINE VOLTAGE FOUR-WAY SWITCH, 20A, 120/277V. MOUNT 46" AFF UON.
LINE VOLTAGE DIMMER SWITCH (WATTAGE AS REQUIRED TO CONTROL THE
FIXTURE(S) CONNECTED UON). MOUNT 46" AFF UON.
OCCUPANCY/VACANCY SENSOR TAGS:
• 'IR' INDICATES INFRARED ONLY
• 'US' INDICATES ULTRASONIC ONLY
• 'HB' INDICATES HIGH BAY
• 'CO' INDICATES CORRIDOR PATTERN
LOW VOLTAGE DUAL TECHNOLOGY OCCUPANCY/VACANCY SENSOR
CONTROLLER, CEILING MOUNTED
LOW VOLTAGE DUAL TECHNOLOGY OCCUPANCY/VACANCY SENSOR
CONTROLLER, WALL MOUNTED
DAYLIGHT HARVESTING SENSOR, CEILING MOUNTED
PHOTO SENSOR
PARTITION SENSOR
LIGHTING CONTROL PANEL
LIGHTING CONTACTOR
TIME SWITCH
LIGHTING
IR
C
T/S
+9' - 6" a
OS
D z1
LC1 RECEPTACLE DEVICE TAG:
• +60 INDICATES MOUNTING HEIGHT IN INCHES AFF.
• 'WP' INDICATES WEATHER-RESISTANT OUTLET WITH WHILE-IN-USE
WEATHERPROOF COVER.
• 'AFI' INDICATES ARC-FAULT CIRCUIT-INTERRUPTER PROTECTION.
• 'AF' INDICATES AFI PROTECTION IS REMOTE OF THE OUTLET.
• 'GFI' INDICATES GROUND-FAULT CIRCUIT-INTERRUPTER PROTECTION.
• 'GF' INDICATES GFI PROTECTION IS REMOTE OF THE OUTLET.
• 'C' INDICATES OUTLET IS CEILING MOUNTED.
• 'H' INDICATES OUTLET IS MOUNTED HORIZONTALLY.
• 'EWC'INDICATES OUTLET FOR ELECTRIC WATER COOLER.
SIMPLEX CONVENIENCE RECEPTACLE - 20A, 125VAC. MOUNT 18" AFF UON.
DUPLEX CONVENIENCE RECEPTACLE, 20A, 125VAC. MOUNT 18" AFF UON.
QUADRUPLEX CONVENIENCE RECEPTACLE MOUNTED IN TWO-GANG OUTLET
BOX - EACH RATED 20A, 125 VOLTS WITH SINGLE COVER PLATE. MOUNT 18"
AFF UON.
DEVIATIONS OF THE ABOVE RECEPTACLE TYPES
• BOX INDICATES OUTLET IS SURFACE MOUNTED.
• HATCH INDICATES MOUNT 46" AFF OR 6" ABOVE BACKSPLASH OR
COUNTERTOP WHERE COUNTER IS INDICATED.
• HATCH INDICATES INTERNAL GROUND FAULT (GFI) PROTECTION.
• HATCH INDICATES INTERNAL GROUND FAULT (GFI) PROTECTION AND
MOUNT 46" AFF OR 6" ABOVE BACKSPLASH OR COUNTERTOP WHERE
COUNTER IS INDICATED.
• FILLED DIAMOND INDICATES INTERNAL ARC FAULT (AFI) PROTECTION.
• OPEN DIAMOND INDICATES INTEGRAL ILLUMINATED FACE OR INDICATOR
LIGHT.
• ONE POWER SYMBOL INDICATES HALF OF OUTLET IS AUTOMATICALLY
CONTROLLED. REFER TO DETAIL ______.
• TWO POWER SYMBOLS INDICATE ENTIRE OUTLET IS AUTOMATICALLY
CONTROLLED. REFER TO DETAIL ______.
• HATCH INDICATES HALF OF OUTLET IS MANUALLY CONTROLLED BY WALL
SWITCH.
• HATCH INDICATES ENTIRE OUTLET IS MANUALLY CONTROLLED BY WALL
SWITCH.
• OPEN SQUARE INDICATES FOR TELEVISION OUTLET, MOUNT AT ____" AFF.
• FILLED SQUARE INDICATES FOR A/V OUTLET, COORDINATE EXACT
LOCATION AND MOUNTING HEIGHT WITH A/V DRAWINGS.
• OPEN CIRCLE INDICATES TAMPER-RESISTANT.
• FILLED CIRCLE INDICATES HOSPITAL-GRADE.
• OPEN TRIANGLE INDICATES DEDICATED OUTLET (PRINT/COPY,
MICROWAVES, SHREDDERS, ETC)
• FILLED TRIANGLE INDICATES ISOLATED-GROUND.
• THREE LEGS INDICATES WITH [TWO 'USB TYPE A'] [ONE USB TYPE A AND
ONE USB TYPE C] [TWO USB TYPE C] OUTLETS WITH INTEGRAL
TRANSFORMER.
SPECIAL PURPOSE RECEPTACLE (TYPE OR NEMA CONFIGURATION AS
NOTED). MOUNT 18" AFF UON.
EMERGENCY "RED MUSHROOM" PUSH BUTTON POWER OFF DEVICE [WITH
CLEAR HINGED COVER].
SURGE PROTECTIVE DEVICE
RAISE/LOWER SWITCH (BY EQUIPMENT MANUFACTURER)
FAN CONTROL SWITCH (BY EQUIPMENT MANUFACTURER)
POWER SWITCH, ON/OFF, 20A, 125 V.
• +46 INDICATES MOUNT 46" AFF.
METER BASE
POWER DEVICES
+46
WP+60
BRANCH CIRCUIT OR FEEDER WIRING IN CONDUIT. NO LABEL INDICATES 2#12
CONDUCTORS & 1#12 GND IN 1/2" CONDUIT. CONDUIT LARGER THAN 1/2"
CONDUIT, CONDUCTOR QUANTITY MORE THAN 3, OR WIRE SIZE LARGER
THAN #12 SHALL BE AS INDICATED (SEE LEGEND NOTE 1). PROVIDE SWITCH
LEG CONDUCTORS FOR LIGHTING FIXTURES CONTROLS WHERE REQUIRED.
HOMERUNS TO PANEL. PANEL AND CIRCUIT DESIGNATIONS AS INDICATED.
INDICATES A CONDUIT RUN CONCEALED IN CEILING, WALL, FLOOR OR ABOVE
SUSPENDED CEILING UON.
CONDUIT TURNED UP
CONDUIT TURNED DOWN
CONDUIT SEAL
LOW VOLTAGE EMERGENCY LIGHT CIRCUIT
LIMITED ENERGY CONTROL CIRCUIT. PROVIDE BETWEEN LOW VOLTAGE
CONTROL STATION AND SYSTEM CONTROL EQUIPMENT INDICATED.
WIRE, CONDUIT AND RACEWAY
L2A-1,3
1 DEMOLITION NOTE IDENTIFICATION
CONSTRUCTION NOTE IDENTIFICATION
HALFTONE SOLID INDICATES EXISTING ITEM AND/OR NO WORK ON SHEET
DARK AND DASHED INDICATES ITEM TO BE REMOVED (SEE LEGEND NOTE 6)
HATCH INDICATES ITEM TO BE REMOVED (SEE LEGEND NOTE 6)
DARK AND SOLID INDICATES NEW ITEM
POINT OF DEMOLITION
POINT OF CONNECTION, NEW-TO-EXISTING (SEE LEGEND NOTE 3)
ROOM NAME/NUMBER
GENERAL
ABBREVIATIONS
BREAK ROOM
LPS AIR TERMINAL. 'A' INDICATES TYPE. SEE DETAILS ON SHEET ____
THROUGH-ROOF ASSEMBLY. 'T1' INDICATES TYPE. SEE DETAILS ON SHEET
LPS ROOF CONDUCTOR
LPS MAIN DOWN CONDUCTOR
GROUND RING (EARTH ELECTRODE SUBSYSTEM) CONDUCTOR
DRIVEN GROUND ROD
DRIVEN GROUND ROD WITH INSPECTION PIT / TEST WELL
CONDUCTOR CONNECTION
CONNECTION TO STRUCTURE
GROUND BAR. SEE GROUNDING ELECTRODE SYSTEM DETAIL _____.
SUBSCRIPT INDICATES THE FOLLOWING:
• 'IBTB' INDICATES INTERSYSTEM BONDING TERMINAL BAR
• 'GB' INDICATES GROUND BAR
• 'ESD' INDICATES ELECTROSTATIC DISCHARGE
• 'PBB' INDICATES PRIMARY BONDING BUSBAR
• 'SBB' INDICATES SECONDARY BONDING BUSBAR
GROUNDING ELECTRODE
SURGE ARRESTER
LIGHTNING PROTECTION AND GROUNDING
R
D
G
A
T1
GB
COMBO DEVICE TAG:
• +60 INDICATES MOUNTING HEIGHT IN INCHES AFF.
• 'WP' INDICATES WEATHER-RESISTANT OUTLET WITH WHILE-IN-USE
WEATHERPROOF COVER.
• 'AFI' INDICATES ARC-FAULT CIRCUIT-INTERRUPTER PROTECTION.
• 'AF' INDICATES AFI PROTECTION IS REMOTE OF THE OUTLET.
• 'GFI' INDICATES GROUND-FAULT CIRCUIT-INTERRUPTER PROTECTION.
• 'GF' INDICATES GFI PROTECTION IS REMOTE OF THE OUTLET.
• 'C' INDICATES OUTLET IS CEILING MOUNTED.
• 'H' INDICATES OUTLET IS MOUNTED HORIZONTALLY.
• 'S' INDICATES OUTLET IS SURFACE MOUNTED.
FLOOR BOXES - REFER TO FLOORBOX SCHEDULE ON SHEET ___ FOR TYPE.
• FLUSH FLOORBOX POWER OUTLET, 20 A, 125 VAC
• FLUSH MULTI-OUTLET FLOORBOX WITH COMBINATION OF POWER (20A,
125VAC), TELECOMMUNICATIONS OUTLET AS INDICATED, AND A/V AS
INDICATED.
• FLUSH POKE-THRU POWER OUTLET FLOORBOX WITH MINIMUM FIRE
RATING OF THE FLOOR ASSEMBLY. 20 A, 125 VAC.
• FLUSH POKE-THRU MULTI-OUTLET FLOORBOX WITH COMBINATION OF
POWER (20A, 125VAC), DATA, AND A/V AS INDICATED.
MULTI-OUTLET SURFACE [METAL] RACEWAY WITH [SEPARATE SECTIONS FOR]
POWER [AND TELECOMMUNICATIONS] OUTLETS. SOLID HATCH INDICATES
NUMBER OF DUPLEX RECEPTACLES [WITH INTERNAL GROUND FAULT
PROTECTION], 20 A, 125 VAC, EVERY [2'-0"] OF LENGTH.
[TELECOMMUNICATION OUTLETS AS INDICATED]. MOUNT 46" AFF OR 6" ABOVE
BACKSPLASH OR COUNTERTOP WHERE COUNTER IS INDICATED.
COMBINATION BACKBOX [WITH HINGED COVER]. [REFER TO AV DRAWINGS
FOR DETAILS AND EXACT MOUNTING LOCATION] ['8' INDICATES NUMBER OF
GANGS. REFER TO AV COMBINATION WALL BOX SCHEDULE ON SHEET _____]
SYSTEMS FURNITURE WITH SEPARATE CHANNELS FOR POWER AND
COMMUNICATIONS ROUTING AND CONNECTIONS. SEE DETAIL ____.
• FOR POWER CONNECTION TO A PRE-WIRED WIRING HARNESS WITH THE
FOLLOWING CONFIGURATION[S]:
1. [8-WIRE HARNESS CONSISTING OF 3 CIRCUIT CONDUCTORS, 3 NEUTRAL
CONDUCTORS, AND 2 EGC]
2. [10-WIRE HARNESS CONSISTING OF 4 CIRCUIT CONDUCTORS, 4
NEUTRAL CONDUCTORS, AND 2 EGC]
3. [5-WIRE HARNESS CONSISTING OF 2 CIRCUIT CONDUCTORS, 2 NEUTRAL
CONDUCTORS, AND 1 EGC]
• FOR COMMUNICATIONS:
1. [4" SQUARE, 2-1/2" DEEP JUNCTION BOX WITH FACEPLATE GROMMIT
OPENING FOR CONTINUOUS CABLING TO THE OUTLETS. PROVIDE
1-1/4"C TO NEAREST ACCESSIBLE MAJOR PATHWAY SYSTEM.]
POWER POLE WITH SEPARATE CHANNELS FOR POWER AND
COMMUNICATIONS ROUTING AND CONNECTIONS.
• FOR POWER CONNECTION TO A PRE-WIRED WIRING HARNESS WITH THE
FOLLOWING CONFIGURATION[S]:
1. [8-WIRE HARNESS CONSISTING OF 3 CIRCUIT CONDUCTORS, 3 NEUTRAL
CONDUCTORS, AND 2 EGC]
2. [10-WIRE HARNESS CONSISTING OF 4 CIRCUIT CONDUCTORS, 4
NEUTRAL CONDUCTORS, AND 2 EGC]
3. [5-WIRE HARNESS CONSISTING OF 2 CIRCUIT CONDUCTORS, 2 NEUTRAL
CONDUCTORS, AND 1 EGC]
• FOR COMMUNICATIONS:
1. [WITH FACEPLATE GROMMIT OPENING FOR CONTINUOUS CABLING TO
THE OUTLETS.]
VOICE/DATA OUTLET. MOUNT 18" AFF, UON. 'c' INDICATES MOUNT 48" AFF OR
6" ABOVE COUNTER TOP WHERE COUNTER IS INDICATED. 'F' INDICATES
OUTLET INSTALLED IN MODULAR FURNITURE. 'M' INDICATED OUTLET
INSTALLED IN MAGISTRATE AREA. 'FM' INDICATES OUTLET INSTALLED IN
MODULAR FURNITURE IN MAGISTRATE AREA. SEE DETAIL D4/ET501H.
TELEPHONE OUTLET. MOUNT 48" AFF, UON. "E" INDICATES OUTLET FOR
EMERGENCY TWO WAY COMMUNICATION. SEE DETAIL D4/ET501H.
SINGLE DATA OUTLET. MOUNT 18" AFF, UON. SEE DETAIL D4/ET501H.
COMBINATION POWER / TELECOM / AV DEVICES
FBP
FPD
FB1
FP1
+60 WP
F
W
VIRGINIA BEACH, VIRGINIA 23462
4525 MAIN STREET, SUITE 1400
757·455·5800
1 2 3 4 5 6
A
B
C
D
E
SHEET
B
C
D
E
DESIGN:
DRAWN:
REVIEW:
REVISIONSDESIGNER
A
PROFESSIONAL SEAL
NOT F
OR C
ONSTRUCTIO
N
5032 ROUSE DRIVE, SUITE 200
VIRGINIA BEACH, VA 23462-3764
757.490.9264
CIVIL CONSULTANT
C U s e rs \C a m e ro n .B a n d y \O n e
D ri v e
C la rk
N e x s e n
\D o c u m e n ts
\1
P o rt s m o u th C o m p le x H
Q
E
C a m e ro n .B a n d y .r v t
/1
/2
:3
:2
P
M
ELECTRICAL LEGEND, NOTES AND
ABBREVIATIONS
CSA
MSW
SPS
CN 1020535% SUBMITTAL DOCUMENTS
JANUARY 16, 2024
PORTSMOUTH PUBLIC SAFETY COMPLEX
CITY OF PORTSMOUTH
3701 WILLETT DR
PORTSMOUTH, VA 23707
E-001
A AMPERE
A/C AIR CONDITIONING
AF AMPERE FRAME
AFCI ARC FAULT CIRCUIT INTERRUPTER
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AHU AIR HANDLING UNIT
ASD ADJUSTABLE SPEED DRIVE
AT AMPERE TRIP
ATC AUTOMATIC TEMPERATURE CONTROL
AWG AMERICAN WIRE GAUGE
B.U.G. BACKLIGHT / UPLIGHT / GLARE
BG BELOW GRADE
BLDG BUILDING
BRKR BREAKER
C CONDUIT
CB CIRCUIT BREAKER
CCT CORRELATED COLOR TEMPERATURE
CKT CIRCUIT
CRI COLOR RENDERING INDEX
DAS DISTRIBUTED ANTENNA SYSTEM
DISC SW DISCONNECT SWITCH
DT DRY TYPE
DVP DOMINION ENERGY
DWG DRAWING
EA EACH
EC EMPTY CONDUIT
EF EXHAUST FAN
ELEC ELECTRICAL
EMT ELECTRICAL METALLIC TUBING
EQUIP EQUIPMENT
ETR EXISTING TO REMAIN
EWC ELECTRIC WATER COOLER
EWH ELECTRIC WATER HEATER
EXIST EXISTING
EXP EXPLOSION PROOF EQUIPMENT
FACP FIRE ALARM CONTROL PANEL
FC FOOTCANDLE
FCU FAN COIL UNIT
FLA FULL LOAD AMPS
FLUOR FLUORESCENT
FMC FLEXIBLE METAL CONDUIT
FT FEET
GFCI GOVERNMENT FURNISHED,
CONTRACTOR INSTALLED
GFGI GOVERNMENT FURNISHED,
GOVERNMENT INSTALLED
GFI GROUND FAULT INTERRUPTER
GND GROUND
GRS GALVANIZED RIGID METAL CONDUIT
HDPE HIGH DENSITY POLYETHYLENE
CONDUIT
HH HANDHOLE
HID HIGH INTENSITY DISCHARGE
HP HORSEPOWER
HPS HIGH PRESSURE SODIUM
IBTB INTERSYSTEM BONDING TERMINATION
BUSBAR
IMC INTERMEDIATE METAL CONDUIT
KAIC THOUSAND AMP CAPACITY, RMS
SYMMETRICAL
KCMIL THOUSAND CIRCULAR MILS
KVA KILOVOLT AMPERE
KWH KILOWATT HOUR
LAN LOCAL AREA NETWORK
LCP LIGHTING CONTROL PANEL
LED LIGHT EMITTING DIODE
LFMC LIQUIDTIGHT FLEXIBLE METAL CONDUIT
LTG LIGHTING
A. WIRING IN CONDUIT, MINIMUM SIZE ONE-HALF (1/2) INCH WITH LARGER SIZES AS INDICATED OR
REQUIRED BY NEC.
B. WIRE AND CABLE MUST BE #12 AWG MINIMUM.
C. FOR PURPOSES OF MOUNTING ELECTRICAL EQUIPMENT OR DEVICES IN AREAS WITH RAISED FLOORING
OR RAISED PLATFORMS, THE TOP OF THE RAISED FLOOR SURFACE MUST BE CONSIDERED THE
FINISHED FLOOR LEVEL.
D. OPENINGS CREATED IN A FIRE OR SMOKE RATED WALL OR FLOOR BY PROVISION OF ANY ELECTRICAL
DEVICE OR CONDUIT MUST BE SEALED AFTER THE WORK IS COMPLETED WITH A UL APPROVED
FIRE/SMOKE SEALANT TO RE-ESTABLISH THE PREVIOUS RATING OF THE WALL OR FLOOR. SEE
ARCHITECTURAL PLANS FOR FIRE RATED WALLS/FLOORS AND THEIR RATING.
E. COORDINATE EXACT LOCATION OF CEILING MOUNTED LIGHTING FIXTURES AND SPEAKERS WITH
ARCHITECTURAL REFLECTED CEILING PLANS.
F. 20A, 120V BRANCH CIRCUIT VOLTAGE DROP MINIMUM SIZES:
a. #10 AWG FROM 100' TO 150'
b. #8 AWG FROM 151' TO 250'
1. WIRE AND CONDUIT FOR MOTOR AND EQUIPMENT LOADS MUST BE CONTINUOUS IN SIZE AND COUNT FROM SOURCE TO FINAL CONNECTION. SIZE AND COUNT AS INDICATED ON THE CIRCUIT HOMERUN
UNLESS OTHERWISE NOTED.
2. WHERE BRANCH CIRCUIT HOMERUNS ARE LABELED "SPLIT CIRCUIT" (SC), THE BRANCH CIRCUIT NUMBER INDICATED HAS BEEN USED ON MORE THAN ONE HOMERUN INDICATOR. ONE CONDUCTOR PER CIRCUIT BREAKER POLE WITHIN THE PANELBOARD ENCLOSURE. SPLICES NECESSARY TO COMPLY WITH THIS REQUIREMENT MUST BE MADE IN A SEPARATE SPLICE BOX OUTSIDE OF THE PANELBOARD ENCLOSURE.
3. WHERE A NEW-TO-EXISTING CONNECTION IS INDICATED, PROVIDE MATERIALS AND LABOR REQUIRED TO
MAKE THE CONNECTION.
4. BRANCH CIRCUIT WIRING TO EXIT LIGHT FIXTURES AND TO THE BATTERY INVERTERS WITHIN FIXTURES
WITH INTEGRAL BATTERY UNITS MUST BE UNSWITCHED, CONNECTED AHEAD OF ANY CONTROL
SWITCHES.
5. AN (*) IN THE FUSE RATING OR TRIP RATING POSITION FOR THIS SYMBOL INDICATES TO PROVIDE FUSE
OR BREAKER TRIP RATING IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATION.
6. WHERE EQUIPMENT OR DEVICES ARE NOTED AS "REMOVE", REMOVE CONDUCTORS ASSOCIATED WITH THESE ITEMS TO THE LAST ACTIVE ITEM ON THE CIRCUIT, OR TO THE BRANCH CIRCUIT BREAKER IF ALL ITEMS ON THE CIRCUIT ARE REMOVED. REMOVE CONDUITS FOR THESE CIRCUITS WHERE THEY RUN EXPOSED OR IN CEILING OR FLOOR PLENUMS. CONDUITS RUN CONCEALED IN WALLS OR FLOOR SLABS MUST BE CUT OFF FLUSH WITH THE SURFACE AND ABANDONED. VOIDS IN WALLS OR FLOOR SLABS LEFT BY THE REMOVAL OF ELECTRICAL EQUIPMENT OR CONDUITS MUST BE FILLED WITH NON-SHRINK GROUT
AND FINISHED TO MATCH ADJACENT SURFACES.
LTS LUMINAIRE
MC METAL-CLAD CABLE
MCA MINIMUM CIRCUIT AMPACITY
MCB MAIN CIRCUIT BREAKER
MH MANHOLE
MI MINERAL-INSULATED,
METAL-SHEATHED CABLE
MIN MINIMUM
MLO MAIN LUG ONLY
MOCP MAXIMUM OVERCURRENT PROTECTION
MSB MAIN SWITCHBOARD
MT MOUNT
MTD MOUNTED
MTG HT MOUNTING HEIGHT
MV MEDIUM VOLTAGE
N/C NORMALLY CLOSED
N/O NORMALLY OPEN
NAC NOTIFICATION APPLIANCE CIRCUIT
NEC NATIONAL ELECTRICAL CODE
NESC NATIONAL ELECTRICAL SAFETY CODE
NEU NEUTRAL
NF NON FUSIBLE
NIC NOT IN CONTRACT
NL NIGHT LIGHT
NTS NOT TO SCALE
OBI OUTLET BASE INFEED
OC OCCUPANCY SENSOR
P POLE
PBB PRIMARY BONDING BUSBAR
(FORMERLY TELECOMMUNICATIONS
MAIN GROUNDING BUSBAR - TMGB)
PH PHASE
PNL PANEL
PVC RIGID POLYVINYL CHLORIDE CONDUIT
QTY QUANTITY
RCPT,
RECEPT
RECEPTACLE
REQ'D REQUIRED
RFI RADIO FREQUENCY INTERFERENCE
RM ROOM
RMC RIGID METAL CONDUIT
S.E., SE SERVICE ENTRANCE
S/N SOLID NEUTRAL
SBB SECONDARY BONDING BUSBAR
(FORMERLY TELECOMMUNICATIONS
GROUND BUSBAR - TGB)
SC SPLIT CIRCUIT (SEE LEGEND NOTE 2)
SF SUPPLY FAN
SPD SURGE PROTECTIVE DEVICE
SPGB SINGLE POINT GROUND BAR
SW SWITCH
TEL TELEPHONE
TELECOM TELECOMMUNICATIONS
TTB TELEPHONE TERMINAL
TV TELEVISION
TYP TYPICAL
UG UNDERGROUND
UH UNIT HEATER
UON UNLESS OTHERWISE NOTED
UP UNDERGROUND PRIMARY POWER
US UNDERGROUND SECONDARY POWER
V VOLTAGE OR VOLTS
VAC VOLTS ALTERNATING CURRENT
VDC VOLTS DIRECT CURRENT
VFD VARIABLE FREQUENCY DRIVE
W WIRE
WH WATER HEATER
WP WEATHERPROOF
X IN SCHEDULES, ITEM NOT APPLICABLE
XFMR TRANSFORMER
Ø PHASE
GENERAL NOTES
LEGEND NOTES
W D
PF
SALLY PORT
H1021
PRIVATE
CORRIDOR
H1022
STAIR
ST2
MEN'S
TOILET
H1046
RECORDS
H1100
RESIDENTIAL
SIMULATOR
H1042
LRG. CONF.
H1043
TELECOM
H1041
ELEC.
H1040
BREAK
H1039
EMS
TRAINING
H1037
EMS
VIEWING
H1036
SML. CONF.
H1035
COMPUTER
CLASSROOM
H1038
LT OFFICE
H1032
STORAGE
H1031
LT
H1034STORAGE
H1033
FIRE
TRAINING
OFFICE
H1028
CLINICAL
H1030
CAPTAIN
H1029
VEHICLE
EXAMINATION
H1014
SHIPPING &
RECEIVING
H1009
OFFICER
LOBBY
H1006
STAIR
ST1
VESTIBULE
H1005
DRUG CAGE
H1004
GUN CAGE
H1003
VESTIBULE
H1001
PUBLIC
LOBBY
H1000
VCIN
TERMINAL
H1047
WOMEN'S
TOILET
H1045
FORENSIC
TECH
H1017
FORENSICS
LAB
H1018
FILE AND
SUPPLY
STORAGE
H1019
CORRIDOR
H1023
AFIS
STORAGE
H1016
FORENSICS
H1013
VESTIBULE
H1012
QUARTERMASTER
H1011A
PROPERTY
& EVIDENCE
H1002
ANIMAL
SERVICES
H1025
STORAGE
H1026
VESTIBULE
H1027
PRIVATE
CORRIDOR
H1010
EQUIPMENT
STORAGE
H1015
VESTIBULE
H1024
LC32
LC23
LC23
LC4
LC19
LC20
LC26
LC26
LC26
LC26
LC5
LC26
LC40LC26
LC30
LC39
LC6
LC25
LC23
LC37
LC20
LC33
LC33
LC20
LC37
LC23
LC9
LC9 LC23
LC30
LC18
LC39
LC39
LC39
LC15
LC39
LC30
LC30
LC20
LC20
LC18
LC16
LC9
LC38 LC38
LC15
LC2
A5
FIRE PUMP
H1008
JAN
H1007
PROPERTY
& EVIDENCE
H1002
CORRIDOR
H1044
EL102H
EL101H
WE
W16
WA
W9
WH WK
W15
W14
WC WGWB WF
W10
W11
W12
W13
WJWD
A5
A5
A5A5A5
A5 A5 A5
A5A5A5
A5A5A5A5
P3P3P3P3
P3P3P3P3
P3P3P3P3
P3P3P3P3
R1P3P3P3
P3P3P3P3
P3P3P3P3
P3P3P3P3
P3P3P3P3
P3P3P3P3
P3 P3
P3 P3
P3P3
P3P3P3P3
P3P3
P3 P3
P3
P3
P3
P3
P3
P3
P3
P3
P3
P3
P3
P3P3P3
P3
P3
P3
P3
P3
P3
P3
P3
P3
P3
P3
P3
P3
CF
CF
D1
D2
D1D1D1
D1
D1D1 D1 D1
D1 D1
D1D1
D1D1D1D1 D1D1
D1D1D1
D1 D1 D1 D1 D1 D1
D1 D1 D1 D1
D2 D2 D2
D2D2
D2
D2
D1 D2
A6
A6
A6 A6
A6
A6
A6 A6
R1
R1
R1
A6 A6 A6 A6
A6 A6
A1 A1 A1
A1A1A1
P3
P3
P3
P3
P3
P3
P3
P3
P3
A6
A6 A6
A1
A1 A1
A1
A6
A6 A6 A6
A6 A6 A6
A6 A6
A6 A6A6
A6
A6
A6
A6
A6
A6
A6
A6
A6
A6
P3
P3 S1
S1
S1
S1
S1
A4 A4 A4 A4 A4 A4
A4
A6A6A6
A6A6A6
A6A6A6
A6A6A6
A6A6A6
A6
A6 A6 A6
A6A6
A6
A6
A6A6
A6 A6
A6
A6A6
A6
A4 A4
A4 A2 A2
A2A2A2
A2
A2
A2
A2
A6A6A6A6
A6
A6
A6 A6
A6
A6
A6
A6
A1
A1
A1
A1
A6A6
A6
A6
A6A6
A6
A6
A1
A2A2A2 A2
A2A2 A2
A2A6A6A6
A6A6A6
P3 P3
P3 P3
P3 P3
P3
DP3
DP3
DP3
DP3
DP3
DP3
A1 A1
A1 A1
A1A1
DP3 DP3
DP3DP3 DP3
DP3
DS
A6
A6
A6
A6
P1P1P1
P1P1P1
P1P1P1
P1P1
P1P1
P1P1
P1 P1
P1
P1 P1
P3P3P3
D2D2D2
P3P3P3
P3P3P3
P3P3P3
DP3
DP3
DP3
DP3
DP3
DP3
D1
D1
D1
D1
A6
A1
A1
A1
A1 A1
A1
A1
A1
A1 A1
A1
A1
A1
P1
P1
P1
P1
V1
LC26
CHANGING
ROOM
H1011B
CHANGING
ROOM
H1011C
LC9
LC24
LC32
PROPERTY
& EVIDENCE
H1002
W1
W1
W2
W2
DS
W2
W2
X1
LC14
JAN
H1020
A2
ELEV.
ELV 1
X1
A2 A2
A2
A2A2A2
A2 A2
A2
W1
W1
S2S2
S2 S2
P3S1
S1 P3 S1
S1
VIRGINIA BEACH, VIRGINIA 23462
4525 MAIN STREET, SUITE 1400
757·455·5800
1 2 3 4 5 6
A
B
C
D
E
SHEET
B
C
D
E
DESIGN:
DRAWN:
REVIEW:
REVISIONSDESIGNER
A
PROFESSIONAL SEAL
NOT F
OR C
ONSTRUCTIO
N
5032 ROUSE DRIVE, SUITE 200
VIRGINIA BEACH, VA 23462-3764
757.490.9264
CIVIL CONSULTANT
C U s e rs \C a m e ro n .B a n d y \O n e
D ri v e
C la rk
N e x s e n
\D o c u m e n ts
\1
P o rt s m o u th C o m p le x H
Q
E
C a m e ro n .B a n d y .r v t
/1
/2
:3
:2
P
M
HQ FIRST FLOOR LIGHTING PLAN - AREA A
CSA
MSW
SPS
CN 1020535% SUBMITTAL DOCUMENTS
JANUARY 16, 2024
PORTSMOUTH PUBLIC SAFETY COMPLEX
CITY OF PORTSMOUTH
3701 WILLETT DR
PORTSMOUTH, VA 23707
EL101H
GRAPHIC SCALE(S)
KEY PLAN
# KEY NOTES
GENERAL NOTES
1/8" = 1' - 0" 0 5' 10' 15' 30'
SCALE: 1/8" = 1'-0"
HQ FIRST FLOOR LIGHTING PLAN - AREA A
A. COORDINATE EXACT LOCATIONS OF ALL LIGHTING FIXTURES WITH
ARCHITECTURAL REFLECTED CEILING PLANS. ENSURE PROPER MOUNTING
EQUIPMENT AND OTHER PROPER APPURTENANCES ARE PROVIDED FOR
CORRECT CEILING TYPE.
B. COORDINATE MOUNTING HEIGHT OF LOCATIONS OF ALL LIGHTING WITH OBJECTS
INCLUDING BUT NOT LIMITED TO DUCTWORK, PIPING, CONDUIT, ETC. SUCH THAT
LIGHT OUTPUT IS NOT OBSCURED BY ANY OBJECT.
C. SEE SHEET E-001 FOR ELECTRICAL LEGEND AND GENERAL NOTES.
A
B C
D
PF
SALLY PORT
H1021
PRIVATE
CORRIDOR
H1022
RECORDS
H1100
VEHICLE
SERVICES
H1110
STORAGE
H1109 BREAK
ROOM
H1108
ARMOR
OFFICE
H1115
SRGT
H1117
STORAGE
H1114
CADET
BREAK
ROOM
H1122
FORCE
SIMULATOR
H1106
CORRIDOR
H1104
PREFUNCTION
SPACE
H1250
RECORDS
H1103
PATROL
GEAR ISSUE
H1102
PUBLIC
LOBBY
H1202
ELEV.
ELV 2
CORRIDOR
H1107
MULTIPURPOSE
ROOM
H1204
STORAGE
H1120
POLY
H1101
LC15
LC39
LC26
LC39
LC26
LC4
LC2
LC25
LC38
LC9
LC39
LC13
LC23
LC30
LC27
LC39
LC26
LC2
ACADEMY
CLASSROOM
H1112
COMPUTER
CLASSROOM
H1111
DEFENSE
TACTICS
TRAINING
CLASSROOM
H1121
STORAGE
H1120A
STORAGE
H1119
LT
H1118
POLICE
TRAINING
OFFICE
H1116
EL101HEL101H
EL103H
EL103H
EL102HEL102H
EL102H
EL102H
WE
W1
WA
W9
WH WKWC WGWB WF
W2
W4
W6
E8EC ED EE
E16
E18
E17
E11
E14
EA
E10EB WJ
W8
EZ
E15
W3
W7
W5
WD
R2
R2
A6 A6
R1
R1
R1
R1
R1
R1
R1
R1
R1
R1
R1
R1
A6
A6 A6
A6 A1
A6
A6
A6
A6
A6
A6
A6
A6
A6
A6
A1
A1A1
A1
A6
A6
A6 A6
A6 A6
A6 A6
A6
A6
A6
A6
A6
A6
A6
A6
A6
A6
A6
A6 A6
A6
A6 A6 A6
A6A6A6
A6 A6 A6
A6
A6
A6
A6
A6
A6
A6
A6
A6
A6
A6
A6 A6
A6
A6
A6
A6A6A6
A6
A6
A6
A6
DS
DS
DS
A1A1A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1A1A1A1
A1A1A1A1
D2
A1
A1
A1
D2
D2
A3
A3
A3
A3
A3
A3A3
A3
A3
DP1
DP1
P3P3P3
P3
P3
P3
P3 P3
P3
LC40
W2
LC10
LC39
LC27
LC9
LC4
A3
A3
A3
A6
A6
VIRGINIA BEACH, VIRGINIA 23462
4525 MAIN STREET, SUITE 1400
757·455·5800
1 2 3 4 5 6
A
B
C
D
E
SHEET
B
C
D
E
DESIGN:
DRAWN:
REVIEW:
REVISIONSDESIGNER
A
PROFESSIONAL SEAL
NOT F
OR C
ONSTRUCTIO
N
5032 ROUSE DRIVE, SUITE 200
VIRGINIA BEACH, VA 23462-3764
757.490.9264
CIVIL CONSULTANT
C U s e rs \C a m e ro n .B a n d y \O n e
D ri v e
C la rk
N e x s e n
\D o c u m e n ts
\1
P o rt s m o u th C o m p le x H
Q
E
C a m e ro n .B a n d y .r v t
/1
/2
:3
:3
P
M
HQ FIRST FLOOR LIGHTING PLAN - AREA B
CSA
MSW
SPS
CN 1020535% SUBMITTAL DOCUMENTS
JANUARY 16, 2024
PORTSMOUTH PUBLIC SAFETY COMPLEX
CITY OF PORTSMOUTH
3701 WILLETT DR
PORTSMOUTH, VA 23707
EL102H
GRAPHIC SCALE(S)
1/8" = 1' - 0" 0 5' 10' 15' 30'
# KEY NOTESGENERAL NOTES
SCALE: 1/8" = 1'-0"
HQ FIRST FLOOR LIGHTING PLAN - AREA B
A
B C
D
KEY PLAN
A. COORDINATE EXACT LOCATIONS OF ALL LIGHTING FIXTURES WITH ARCHITECTURAL REFLECTED CEILING PLANS. ENSURE PROPER MOUNTING
EQUIPMENT AND OTHER PROPER APPURTENANCES ARE PROVIDED FOR CORRECT CEILING TYPE.
B. COORDINATE MOUNTING HEIGHT OF LOCATIONS OF ALL LIGHTING WITH OBJECTS INCLUDING BUT NOT LIMITED TO DUCTWORK, PIPING, CONDUIT, ETC.
SUCH THAT LIGHT OUTPUT IS NOT OBSCURED BY ANY OBJECT.
C. SEE SHEET E-001 FOR ELECTRICAL LEGEND AND GENERAL NOTES.
PREFUNCTION
SPACE
H1250
VISITOR
WAITING
H1211
PROFESSIONAL
STANDARDS
H1209
INTERVIEW
H1212
POLYGRAPH
H1213
RECORD
STORAGE
H1214
WAITING
AREA
H1232
VISITOR
H1228
HEARING
H1235
HEARING
H1236
VISITOR
H1229
VISITOR
H1230
HEARING
H1237
HEARING
H1238
VISITOR
H1231
HEARING
H1239
VISITOR
H1233
MAG
H1241
CONFERENCE
H1242
CHIEF
MAGISTRATE
H1243
PROBABLE
CAUSE
H1245
MAIN ELEC.
H1247
EM. ELEC.
H1246
MECHANICAL
H1248
ELEV.
ELV 3
STAIR
ST3
WOMENS
LOCKER
ROOM
H1301
MENS
LOCKER
ROOM
H1302
COMMERCIAL
KITCHEN &
CAFETERIA
H1300
MED. CONF.
H1222
MED. CONF.
H1223
CORRIDOR
H1104
OUTDOOR
COVERED
SEATING
H1310
REGIONAL
SUPERVISOR
H1244
MENS
H1218
WOMENS
H1219
MENS
H1216
WOMENS
H1217
BREAK
H1251
LC26
LC7
LC42LC42
LC7LC7
LC42
LC7
LC7
LC42
LC25
LC26
LC5
LC39
LC34
LC25
LC25
LC39
LC34
LC42
LC42
LC39
LC4
LC5
LC37
LC19
LC2
LC12
LC33
LC33
LC33
LC33
LC24
LC2
LC2
LC24
LC5
LC25
LC24
MULTIPURPOSE
ROOM
H1204
STORAGE
H1205
BREIFING
ROOM
H1220
PUBLIC
TOILET
H1227
PRIVATE
BATHROOM
H1234
E L1
H
E L1
H
EL104H EL104H
EL103H EL103H
E L1
H
E L1
H
EMEH
E8
EFEC ED EE
E16
E18
E17
EP EQEJ
E11
E13
EG
E14
EA
E10
EBEZ
E15
E12
EL
E9
ENEK
STORAGE
H1224
STO
H1221
FAMILY
WAITING
H1207
AV
H1206
BREAK
ROOM
H1226
LT OFFICE
H1215
MAGISTRATE
H1240
COAT
H1225
INTERVIEW
H1210
D2D2 D2D2D2D2
A5A5 A5
D1D1
A6
A6
A6
A6
A6
A6
A6
A6
A6
P3 P3 P3 P3 P3
P3 P3 P3 P3
P3P3
X1
X1 P3 P3 P3
P3 P3 P3P3
P3
P3P3
A1
A1A1
A1
A1
A1
A1
A1
A1
A1
A1
D1
D1V1
D1
D1
V1
A3A3A3A3
A3 A3 A3 A3
A1
A1
A1A1A1A1
A1
A1A1
A6A6 A6 A6 A6A6A6
A6A6
A6 A6
A6
A6 A6
A6
A1A1 A1
A6
R2R2R2R2R2R2
A6
A6
A6
A6
D1
D1
D1
D1
D1
D1
D1
D1
D1
D1 D1
D1
D1
D1
D2
D2
D2
D2
D2
D2
D2
D2
D1
D1
D1
D1
D1
D1
D1
D1
D1
D1
D1
D1
D1
D1
D2
D2
R2R2R2R2R2 A6
A6
A6
A6
A6
A6
A6
A6
A6
A6A6
A6
A6
A6
A6 A6
A1
A1
A6
A6
A6A6
A6
A6
A6A6A6A6A6
A6
A6
DS
X1
X1
X1X1
A6
P3P3
S1
X1
S1
X1
X1
S1
DS
DS
A6
A6
A6
A1 A1
A1A1
A3A3A3A3A3A3A3A3A3A3A3A3A3A3
A3A3 A3 A3
DP1
DP1
DP1DP1DP1DP1
LC42
A6
A6 A6
A6A6
A1A1
D1 D1 D1
D1D1D1
ENTRANCE
VESTIBULE
H1200
PUBLIC
LOBBY
H1202
A1 A1
A1A1
A1 A1
A1A1
A1 A1
A1A1
D1 D1 D1 D1 D1
D1
D1
A3 A3
DS
S2S2
LC34
VIRGINIA BEACH, VIRGINIA 23462
4525 MAIN STREET, SUITE 1400
757·455·5800
1 2 3 4 5 6
A
B
C
D
E
SHEET
B
C
D
E
DESIGN:
DRAWN:
REVIEW:
REVISIONSDESIGNER
A
PROFESSIONAL SEAL
NOT F
OR C
ONSTRUCTIO
N
5032 ROUSE DRIVE, SUITE 200
VIRGINIA BEACH, VA 23462-3764
757.490.9264
CIVIL CONSULTANT
C U s e rs \C a m e ro n .B a n d y \O n e
D ri v e
C la rk
N e x s e n
\D o c u m e n ts
\1
P o rt s m o u th C o m p le x H
Q
E
C a m e ro n .B a n d y .r v t
/1
/2
:3
:4
P
M
HQ FIRST FLOOR LIGHTING PLAN - AREA C
CSA
MSW
SPS
CN 1020535% SUBMITTAL DOCUMENTS
JANUARY 16, 2024
PORTSMOUTH PUBLIC SAFETY COMPLEX
CITY OF PORTSMOUTH
3701 WILLETT DR
PORTSMOUTH, VA 23707
EL103H
GRAPHIC SCALE(S)
1/8" = 1' - 0" 0 5' 10' 15' 30'
# KEY NOTESGENERAL NOTES
SCALE: 1/8" = 1'-0"
HQ FIRST FLOOR LIGHTING PLAN - AREA C
A. COORDINATE EXACT LOCATIONS OF ALL LIGHTING FIXTURES WITH ARCHITECTURAL REFLECTED CEILING PLANS. ENSURE PROPER MOUNTING
EQUIPMENT AND OTHER PROPER APPURTENANCES ARE PROVIDED FOR CORRECT CEILING TYPE.
B. COORDINATE MOUNTING HEIGHT OF LOCATIONS OF ALL LIGHTING WITH OBJECTS INCLUDING BUT NOT LIMITED TO DUCTWORK, PIPING, CONDUIT, ETC.
SUCH THAT LIGHT OUTPUT IS NOT OBSCURED BY ANY OBJECT.
C. SEE SHEET E-001 FOR ELECTRICAL LEGEND AND GENERAL NOTES.
A
B C
KEY PLAN
WOMENS
LOCKER
ROOM
H1301 MENS
LOCKER
ROOM
H1302
COMMERCIAL
KITCHEN &
CAFETERIA
H1300
OUTDOOR
COVERED
SEATING
H1310
TELECOM
H1304
ELECTRICAL
H1303
GYM
H1305
BASKETBALL
COURT
H1306
BREAK
H1251
LC21 LC21
LC13
LC23
LC12
LC1
LC23
HB HB
HBHB
HB
HBHB
HB
DP2 DP2 DP2 DP2
DP2DP2DP2DP2
DP2
DP2
DP2 DP2
DP2
DP2 DP2 DP2
DP2DP2
DP2
EL103H
EL104H
EL103H
EL104H
EM
E3
EH
E5
E6
E8
EP EQEJ
E4
E7
EL
E9
EN
E1
EK
E2
LC50
A5
D2D2D2
D1
D1
D1
D1
D1
D1
D1
D2
D2
D2
D1D1
D1
D1
D1D1
D1
D1
D1
D1
D1
D1
D1
D1
D1D2
D2
D2
D2 D2D2
A5 A5
A5
A5
A5 A5
A5
A5
P3
P3
P3
P3
P3
P3
P3
P3
P3
P3
P3
P3 P3
P3 P3
A5A5
D1D1 D1
D1
D1
D1
D1
D1
D2
D2
D2
D2
D1 D1 D1
D1
D1
D1D1
D1
D1
D1 D1
A6A6A6A6A6
A6
A6
A6 A6
X1
X1
X1
X1 DS
X1
X1
W1
W1
W1
W1
GYM
H1305
ELECTRICAL
H1307 W1
W1
W1
VIRGINIA BEACH, VIRGINIA 23462
4525 MAIN STREET, SUITE 1400
757·455·5800
1 2 3 4 5 6
A
B
C
D
E
SHEET
B
C
D
E
DESIGN:
DRAWN:
REVIEW:
REVISIONSDESIGNER
A
PROFESSIONAL SEAL
NOT F
OR C
ONSTRUCTIO
N
5032 ROUSE DRIVE, SUITE 200
VIRGINIA BEACH, VA 23462-3764
757.490.9264
CIVIL CONSULTANT
C U s e rs \C a m e ro n .B a n d y \O n e
D ri v e
C la rk
N e x s e n
\D o c u m e n ts
\1
P o rt s m o u th C o m p le x H
Q
E
C a m e ro n .B a n d y .r v t
/1
/2
:3
:4
P
M
HQ FIRST FLOOR LIGHTING PLAN - AREA D
CSA
MSW
SPS
CN 1020535% SUBMITTAL DOCUMENTS
JANUARY 16, 2024
PORTSMOUTH PUBLIC SAFETY COMPLEX
CITY OF PORTSMOUTH
3701 WILLETT DR
PORTSMOUTH, VA 23707
EL104H
SCALE: 1/8" = 1'-0"
HQ FIRST FLOOR LIGHTING PLAN - AREA D
A. COORDINATE EXACT LOCATIONS OF ALL LIGHTING FIXTURES WITH
ARCHITECTURAL REFLECTED CEILING PLANS. ENSURE PROPER MOUNTING
EQUIPMENT AND OTHER PROPER APPURTENANCES ARE PROVIDED FOR
CORRECT CEILING TYPE.
B. COORDINATE MOUNTING HEIGHT OF LOCATIONS OF ALL LIGHTING WITH OBJECTS
INCLUDING BUT NOT LIMITED TO DUCTWORK, PIPING, CONDUIT, ETC. SUCH THAT
LIGHT OUTPUT IS NOT OBSCURED BY ANY OBJECT.
C. SEE SHEET E-001 FOR ELECTRICAL LEGEND AND GENERAL NOTES.
GRAPHIC SCALE(S)
KEY PLAN
# KEY NOTES
GENERAL NOTES
1/8" = 1' - 0" 0 5' 10' 15' 30'
A
STAIR
ST2
LT
H2026
MEN'S
TOILET
H2054
TELECOM
H2022
NARCOTICS
H2023
STORAGE
H2024
SURVEILLANCE
EQUP.
H2025
DISTRICT
LTS
H2019
ASSISTANT
CHIEF
H2055
PIO
H2056
PIO
H2057
ASSISTANT
CHIEF
H2065
LOBBY
H2018
GSU
STORAGE
H2016
GANG
SUPPRESSION
H2017
INTERVIEW
H2015
CRIMINAL
INVESTIGATIONS
H2010
CAPTAIN
H2004
LT
H2005 STORAGE
H2006
STORAGE
H2007
MD. CONF.
H2008
STORAGE
H2012
STORAGE
H2013
SPECIAL
OPS
H2011
LT
H2014
MD. CONF.
H2000
BREAK
ROOM
H2003
STAIR
ST1
ELEV.
ELV 4
UNISEX
H2041
UNISEX
H2040
HOLDING
H2039
HOLDING
H2038 HOLDING
H2037
HOLDING
H2036
HOLDING
H2035
AV
MONITORING
H2042
INTERVIEW
H2043
HOLDING
H2046
HOLDING
H2047
HOLDING
H2048
HOLDING
H2049
HOLDING
H2050
PRIVATE
INTERVIEW
CORE
H2028
INTERVIEW
H2045
AV
MONITORING
H2044
INTERVIEW
H2051
AV
MONITORING
H2033
INTERVIEW
H2034
HOLDING
H2032
HOLDING
H2031
HOLDING
H2030
HOLDING
H2029
VESTIBULE
H2027
LRG. CONF.
H2001
WOMEN'S
TOILET
H2053
LC39
LC26
LC40
LC30
LC39
LC39
LC25
LC20
LC30
LC26
LC26
LC26
LC26
LC26
LC39
LC39
LC26
LC38
LC7
LC7 LC7 LC7
LC7
LC7LC7LC7LC7LC7
LC20LC7LC7LC7LC7
LC25
LC25
LC25
LC26
LC26
LC7
LC34
LC25
LC26
LC9
LC34
LC2
LC23
LC37
LC23
LC37
LC20
LC26
LC6
LC30
LC39
LC30
LC8
LC23
LC23
LC33
LC33
LC8
LC5
LC26
LC9
EL106H
EL105H
WE
W16
WA
W9
WH WK
W15
W14
WC WGWB WF
W10
W11
W12
W13
WJWD
STORAGE
H2020
ELEC.
H2021
SECURITY
H2052
ADMIN
SERVICES
H2249
A6 A6
A6 A6
A6 A6
A6 A6
D2D2D2
D1D1D1D1 D1D1
D2D2D2
D1D1D1D1
D1D1D1D1
D1D1D1D1
D1 D1
A6
A6
A6
A6
A6
A6
A6
A6
A6
A6
A6A6A6A6A6A6A6A6
A6
A6
A1 A1
A1 A1
A6
A6 A6 A6 A6 A6 A6
A6 A6A6A6A6A6A6 A6
A6 A6 A6 A6 A6 A6 A6 A6
A6 A6 A6 A6 A6 A6 A6 A6
A6A6A6A6A6A6A6
A6 A6 A6 A6
A6 A6
A6
A6 A6
A6
A6 A6 A6 A6 A6
A6 A6
A6 A6
A6 A6 A6
A6
A4A4A4 A4
A4A4A4A4A4
A4A4A4A4A4
D1D1
D1D1
V1
V1
P3
P3
P3
P3
A6
A6
A6
A6A6
A6
A6
A6A6
A4A4
A4
A4
A4
A4
A6
A6 A6 A6 A6
A6 A6
A6
A6
A6 A6
A6 A6
A6
A6
A6A6 A1
A6 A6
A6A6
A6A6
A6 A6
A6 A6
P3
P3
A6
A6 A6
A6
A6 A6
A6
A6
A4 A4
A6 A6 A6
A6 A6 A6
A6 A6 A6
A6 A6 A6
A6
A6 A6 A6
A6A6
S1
S1 S1
A1 A1 A1
A1
A1
A1A1
A1 A1
A1 A1
A1 A1
A1 A1
A1
A1
A1
A1
A1
A1
A4A4A4
A4
A4 A4 A4
A4
A4 A4
A4
A4 A4 A4 A4 A4
A4
A4
A4
S1
S1
A6
A6
P3
P3 S1
S1
VIRGINIA BEACH, VIRGINIA 23462
4525 MAIN STREET, SUITE 1400
757·455·5800
1 2 3 4 5 6
A
B
C
D
E
SHEET
B
C
D
E
DESIGN:
DRAWN:
REVIEW:
REVISIONSDESIGNER
A
PROFESSIONAL SEAL
NOT F
OR C
ONSTRUCTIO
N
5032 ROUSE DRIVE, SUITE 200
VIRGINIA BEACH, VA 23462-3764
757.490.9264
CIVIL CONSULTANT
C U s e rs \C a m e ro n .B a n d y \O n e
D ri v e
C la rk
N e x s e n
\D o c u m e n ts
\1
P o rt s m o u th C o m p le x H
Q
E
C a m e ro n .B a n d y .r v t
/1
/2
:3
:5
P
M
HQ SECOND FLOOR LIGHTING PLAN -
AREA A
CSA
MSW
SPS
CN 1020535% SUBMITTAL DOCUMENTS
JANUARY 16, 2024
PORTSMOUTH PUBLIC SAFETY COMPLEX
CITY OF PORTSMOUTH
3701 WILLETT DR
PORTSMOUTH, VA 23707
EL105H
SCALE: 1/8" = 1'-0"
HQ SECOND FLOOR LIGHTING PLAN - AREA A
A. COORDINATE EXACT LOCATIONS OF ALL LIGHTING FIXTURES WITH
ARCHITECTURAL REFLECTED CEILING PLANS. ENSURE PROPER MOUNTING
EQUIPMENT AND OTHER PROPER APPURTENANCES ARE PROVIDED FOR
CORRECT CEILING TYPE.
B. COORDINATE MOUNTING HEIGHT OF LOCATIONS OF ALL LIGHTING WITH OBJECTS
INCLUDING BUT NOT LIMITED TO DUCTWORK, PIPING, CONDUIT, ETC. SUCH THAT
LIGHT OUTPUT IS NOT OBSCURED BY ANY OBJECT.
C. SEE SHEET E-001 FOR ELECTRICAL LEGEND AND GENERAL NOTES.
GRAPHIC SCALE(S)
KEY PLAN
# KEY NOTES
GENERAL NOTES
1/8" = 1' - 0" 0 5' 10' 15' 30'
A
ADMIN
SERVICES
H2249
CRIME
ANALYSIS
H2108
SM. CONF.
H2105
EXECUTIVE
CONF.
H2104
COPY/PRINT
H2100
ASSISTANT
CHIEF
H2101
CHIEF OF
POLICE
H2103
DIRECTOR
H2135
SUPERVISOR
H2136
EMS
H2130
POLYGRAPH
H2131
OPEN TO BELOW
STREET
CRIMES
H2125
MOTHERS
H2128
WELLNESS
ROOM
H2129
ELEV.
ELV 2
PLATOON 1
H2116
PLATOON 2
H2117
CORRIDOR
H2114B
PLATOON 3
H2120
PLATOON 4
H2121
LT
H2122
CAPT
H2123
CAPT
H2124
STORAGE
H2126
FUGITIVE
APPREHENSION
H2112
STORAGE
H2113
BREATHALYZER
H2111
REPORT
H2115
ROLL CALL
H2119 ADMIN
SERVICES
H2133
HOLDING
H2046
STORAGE
H2118
LC25
LC5
LC5
LC5
LC26
LC26
LC8
LC26
LC25
LC26
LC30
LC15
LC39
LC30
LC30
LC30
LC39
LC30
LC23
LC39
LC2
LC26
LC30
LC26LC26
LC2
LC9
LC2
LC6
LC5
EL105HEL105H
EL107H
EL107H
EL106HEL106H
EL106H
EL106H
WE
W1
W9
WH WKWC WGWF
W2
W4
W6
E8EC ED
E16
E17
E11
E14
EA E10EB WJ
W8
EZ
E15
W3
W7
W5
WD
SOFT
INTERVIEW
H2107
SOFT
INTERVIEW
H2106
PLOTTER
WORK AREA
H2110
CRIME
ANALYSIS
SVR
H2109
CORRIDOR
H2114B A6
A6
A6
A6
A6
A6
A6
A6
A6
A6 A6
A6
A6
A6
A6
A6
A6
A6
A1
A1
A1
A1
A6
A6
A6
A6 A6
A6
A6 A6 A6
A6 A6
A6 A6
A6
A6 A6 A6
A6 A6
A6A6A6
A6 A6 A6
A6 A6
A6 A6 A6
A6A6A6
A6A6
A6
A6
A6
A6
A6
A6 A6 A6
A6A6A6
A6
A6
A6 A6
A6
A6A6
A6
A6
A6 A6
A6
A6
A6A6
A6
A6 A6
A6
A6
A6
A6
A6
A6
A6
A6
A6
A6
A6
A6 A6 A6
A6
A6
A6
A6
A6
A6
A6
A6
A6 A6 A6
A6 A6 A6
A6 A6
A6
A6
A6
A6 A6
A6
A6 A6 A6 A6
A1
A1
A1
A1A1
A1
A1 A1
A1
D1
D2
D1
D1
D1
D1
D1
A1A1
A1
A1 A1
A1
A1
A1
A1
A1 A1 A1
A1A1A1
TL
D2
D2
D1
D1
D1
D1
D1
D1
D1
D1
D1
A6
A6A6A6
A6 A6
BREAK
H2127
ASSISTANT
CHIEF
H2065
CHIEF OF
POLICE
H2103
A6
D2
D2D2D2D2
D2
D2
D2
D2
D2
D2
D2
D2
D2
VIRGINIA BEACH, VIRGINIA 23462
4525 MAIN STREET, SUITE 1400
757·455·5800
1 2 3 4 5 6
A
B
C
D
E
SHEET
B
C
D
E
DESIGN:
DRAWN:
REVIEW:
REVISIONSDESIGN…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .