Public Safety Complex - Preliminary Drawings_Part2.pdf

PDF 21 MB Posted

Attached to
REQUEST FOR PROPOSAL (RFP) # 49-26-SKL PPEA Project to Construct a Public Safety Facility
Solicitation number
RFP-121372
Issued by
Portsmouth City, Virginia

About this file

This is a preliminary architectural drawings document prepared by Clark Nexsen for the Portsmouth Public Safety Complex in Portsmouth, Virginia, a multi-building facility designed to house police, fire, emergency medical services, and emergency operations center functions. The project represents a significant public safety infrastructure investment featuring approximately 150,000 square feet of construction across headquarters, training, and warehouse facilities. The drawings specify a two-story headquarters building with precast concrete construction, 28-inch deep precast prestressed double-tee roof systems with cast-in-place concrete topping, reinforced masonry walls on pile-supported foundations, and comprehensive interior programming including administrative offices, training facilities, forensic laboratories, detention holding areas, dispatch centers, and operational support spaces. The facility is designed to accommodate police administration, criminal investigation divisions, emergency management functions, fire department operations, EMS administration, and emergency operations center staff with segregated facilities for evidence and property management, vehicle examination, and training simulation spaces.

The structural design incorporates significant load criteria reflecting the facility's operational demands, including 150 PSF storage loads, HS-20 wheel loads for vehicle examination areas, and 130 MPH wind design speeds appropriate to the Virginia coastal location. Foundations are designed for 4,000 PSF net allowable bearing capacity on engineered fill with rigid inclusions per geotechnical recommendations, and the project utilizes precast concrete wall panels as the primary lateral load-resisting system acting as shear walls. The design includes comprehensive details for reinforced masonry, concrete slabs-on-grade with construction and control joints, wall folding reinforcement, and column-to-foundation connections. All precast concrete manufacturing and lateral load-resisting system design is delegated to the contractor's specialty structural engineer per PCI Design Handbook standards. The submittal documents dated January 16, 2024, indicate this project is being advanced under the PPEA procurement structure referenced in the related RFP 49-26-SKL with proposal submissions due July 29, 2026.

View the file

Other files

Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

NOT AT CONTROL JOINT

SEE LINTEL SCHEDULE

FOR SIZE AND

REINFORCING

AT CONTROL JOINT

GROUT SOLID

24" DEEP x16" WIDE

ADDITIONAL VERTICAL

WALL REINFORCING

JAMB VERTICAL

REINFORCING,

OFFSET AND

LAP 48 BAR

DIAMETERS

0' - 3'-4"

BOND BEAM LINTEL SCHEDULE

8" (2) #4 BOTTOM8"

NOTE:

VENEER MASONRY AND ANGLE

LINTELS NOT SHOWN FOR CLARITY.

SECTION

TOP REINFORCING,

SEE LINTEL SCHEDULE

TYPICAL VERTICAL

REINFORCING MOW

(IF SPACING IS LESS

THAN CLEAR SPAN)

BOTTOM REINFORCING,

SEE LINTEL SCHEDULE

[SEE ARCH]

BOTTOM

OF LINTEL

D

W

MASONRY

CONTROL JOINT

CLEAR SPAN DEPTH 'D' REINFORCINGWIDTH 'W'

BRG

8"

BRG

8"

3'-5" - 5'-4" 8" (2) #5 BOTTOM8"

5'-5" - 6'-8" 16" (2) #5 BOTTOM8"

NOTE:

FOR ADDITIONAL INFORMATION,

SEE 'NOT AT CONTROL JOINT'.

PLAN AT CORNER PLAN AT INTERSECTION

2 ADDITIONAL

BARS AS SHOWN,

SAME SIZE AS

CONT REINF

CONT BOND

BEAM REINF

ADDITIONAL

CORNER BARS

AS SHOWN,

SAME SIZE AS

CONT REINF

T Y

P

1' -6

LA

P0", TYP

1'-6"

0", TYP

CORNERINTERSECTION CONTROL JOINT

OPENING -

WALL TERMINATION

VERTICAL WALL

REINFORCING,

MOW (TYP)

VERTICAL WALL

REINFORCING,

MOW (TYP)

CONTROL JOINT,

SEE ARCH DWGS FOR

LOCATIONS AND DETAILS

TYPICAL VERTICAL

WALL REINFORCING,

(3) BARSMOW AS SHOWN

VERTICAL WALL

REINFORCING, MOW (TYP)

JOINT REINFORCING

FACTORY-PREFAB

TEE UNIT AT

INTERSECTIONS

COURSE BLOCKS TOGETHER

(OVERLAP) AT INTERSECTION

OR PROVIDE RIGID STEEL

ANCHORS AT 4'-0" OC, MAX;

FILL CELLS TO END OF RIGID

ANCHOR WITH GROUT

JOINT REINFORCING

FACTORY-PREFAB CORNER

UNIT AT INTERSECTIONS

COURSE BLOCKS

TOGETHER (OVERLAP)

AT CORNERS

SEALANT AND

BACKER ROD,

EACH FACE

SASH BLOCK

CONT RIGID GASKET

SQUARE END

MASONRY UNIT

'A' AND

'C' BARS

CONT

'B' AND

'D' BARS

L

C O

N T

PLAN AT WALL

WALL

'A' AND

'C' BARS

'B' AND

'D' BARS

PLAN AT COLUMN

COLUMN,

WALL SIMILAR

W

L

SECTION

'B' BARS'A' BARS

'D' BARS'C' BARS

W

T

W

SUPPORTS FOR

REINFORCEMENT AT

3'-0" OC EACH WAY, MAX

POROUS FILL

[SEE PLAN]

TOC

VAPOR RETARDER

SLAB REINFORCEMENT,

SEE PLAN (TYP)

1/

2"

U O

N CONCRETE

SLAB-ON-GRADE

SAWCUT JOINT, DEPTH

EQUAL TO 1/4 OF

SLAB THICKNESS

TYPICAL SLAB-ON-GRADE SAWED JOINT (SJ)

CONCRETE

SLAB-ON-GRADE

2x4 CONT KEY

APPLY LIQUID CURING

COMPOUND TO ENTIRE

FACE OF PREVIOUS POUR

TO PREVENT BONDING

SLAB REINFORCEMENT,

SEE PLAN (TYP)

PREVIOUS POUR

CONCRETE

SLAB-ON-GRADE

2" CLR, TYP

6" 6"

CONSTRUCTION JOINT (CJ)

SEE PLANSEE PLAN

[SEE PLAN]

TOC

1' -0

SEE PLAN

[SEE PLAN]

TOC

1CUT REINFORCEMENT

ALONG JOINT LINES

SLAB REINFORCEMENT,

SEE PLAN (TYP)

3" 3"

NOTES:

1. POSITION DOWELS

PERPENDICULAR TO JOINT

AND PARALLEL TO TOP OF SLAB.

2. SUPPORT DOWELS

INDEPENDENTLY OF REINFORCING.

[SEE PLAN]

TOC

4" 4"

E Q

E Q

SLAB REINFORCEMENT,

SEE PLAN

APPLY LIQUID CURING

COMPOUND ALONG ENTIRE

FACE OF PREVIOUS POUR

TO PREVENT BOND

SEE PLAN

JOINT DOWEL:

1"Ø x1'-8" LONG

SMOOTH BAR AT 12" OC

CONCRETE

SLAB-ON-GRADE

PREVIOUS POUR

CONCRETE

SLAB-ON-GRADE

POROUS FILL

[SEE PLAN]

TOC

SEE PLAN

VAPOR RETARDER

SLAB REINFORCEMENT,

SEE PLAN

2" C

LR

NOTES:

1. POSITION DOWELS

PERPENDICULAR TO JOINT

AND PARALLEL TO TOP OF SLAB.

2. SUPPORT DOWELS

INDEPENDENTLY OF REINFORCING.

CONCRETE

SLAB-ON-GRADE

[SEE PLAN]

TOC

4" 4"

E Q

E Q

SLAB REINFORCEMENT,

SEE PLAN

JOINT DOWEL:

1"Ø x1'-8" LONG

SMOOTH BAR AT 12" OC

SAWCUT JOINT

(3" DEEP)

SEE PLAN

TYPICAL SLAB-ON-GRADE

DOWELED

CONSTRUCTION JOINT (DCJ)

DOWELED

SAWED CONTRACTION JOINT (DSJ)

JOINT SEALANT

JOINT SEALANT,

SEE TYPICAL DETAIL

GREASE DOWEL PRIOR TO

CONCRETE PLACEMENT

3" C

LR

[SEE ARCH]

TOM

STEEL FRAME BY METAL

BUILDING SUPPLIER

CMU WALL, SEE PLAN

AND SCHEDULE

1/2"Ø ANCHOR ROD

AT 6'-0" OC MAX

(5" EMBEDMENT)

PROVIDE (2) AT CMU

PIERS < 6'-0" WIDE

GIRT SUPPORTING

TOP OF WALL BY METAL

BUILDING SUPPLIER

CONT BOND BEAM

AT TOP OF WALL

VENEER,

SEE ARCH DWGS

3'-0"

3' -0

TYP

1'-6"

CONTINUOUS TURNED

DOWN SLAB REINFORCING,

SEE SECTIONS (TYP)

NOTE:

WHERE THREE BARS

OCCUR, TREAT

CENTER BAR AS AN

INNER FACE BAR

0", TYP

PLAN AT

INTERSECTION

PLAN AT

CORNER

SEE FOOTING

SCHEDULE ON

THIS SHEET

REINFORCING (TYP)

NOTES:

1. WHERE THREE BARS

OCCUR, CENTER BAR

SHALL BE TREATED

AS AN INNER FACE BAR.

2. 'B' AND 'D' BARS NOT

SHOWN FOR CLARITY.

3' -0

TYP

1'-6"

3'-0"

0", TYP

1'-6" 1'-6"

0" , T

Y P

VIRGINIA BEACH, VIRGINIA 23462

4525 MAIN STREET, SUITE 1400

757·455·5800

1 2 3 4 5 6

A

B

C

D

E

SHEET

B

C

D

E

DESIGN:

DRAWN:

REVIEW:

REVISIONSDESIGNER

A

PROFESSIONAL SEAL

NOT F

OR C

ONSTRUCTIO

N

5032 ROUSE DRIVE, SUITE 200

VIRGINIA BEACH, VA 23462-3764

757.490.9264

CIVIL CONSULTANT

C U s e rs \S

S M

IT

H

\D o c u m e n ts

\R e v it P ro je c ts

\2

\1

P o rt s m o u th

C o m p le x W a re h o u s e

S s s m it h

Z C

M

Y .r v t

/1

/2

:5

:3

P

M

WAREHOUSE TYPICAL DETAILS

SDS

SMS

LSS

CN 1020535% SUBMITTAL DOCUMENTS

JANUARY 16, 2024

PORTSMOUTH PUBLIC SAFETY COMPLEX

Owner

PROJECT ADDRESS

SB501W

NOT TO SCALE

A1

TYPICAL BOND BEAM LINTEL

NOT TO SCALE

B3

TYPICAL BOND BEAM REINFORCING

NOT TO SCALE

B1

TYPICAL REINFORCED MASONRY WALL

FOOTING SCHEDULE

MARK

DIMENSIONS REINFORCING

NOTESW L T 'A' BARS 'B' BARS 'C' BARS 'D' BARS

F3.0 3'-0" 3'-0" 1'-0" - - - -

F7.0 7'-0" 7'-0" 2'-0" - - - -

F8.0 8'-0" 8'-0" 2'-0" - - - -

F101 8'-0" 11'-0" 2'-0" - - - -

WF2.0 2'-0" CONT 1'-0" - - - -

WF5.0 5'-0" CONT 1'-8" - - - -

NOT TO SCALE

E2

TYPICAL FOOTING REINFORCING DIAGRAMS

NOT TO SCALE

C4

TYPICAL 5" THICK CONCRETE SLAB-ON-GRADE DETAILS

NOT TO SCALE

C1

TYPICAL 10" THICK CONCRETE SLAB-ON-GRADE DETAILS

NOT TO SCALE

B5

TYPICAL TOP OF EXTERIOR

MASONRY WALL AT METAL BUILDING

NOT TO SCALE

E6

TYPICAL CONTINUOUS TURNED

DOWN SLAB REINFORCING

NOT TO SCALE

E4

TYPICAL CONTINUOUS FOOTING REINFORCING

DESIGN LOAD CRITERIA

1. LIVE LOADS (UNIFORM)

PARTITION ALLOWANCE 15 PSF

OFFICES 50 PSF

TOILETS 75 PSF

STORAGE 150 PSF

ELECTRICAL ROOMS 125 PSF

MECHANICAL ROOMS 150 PSF

LIVE LOADS (CONCENTRATED)

OFFICE CONCENTRATED LOAD (APPLIED TO 6.25 FT2) 2,000 LB

WHEEL LOAD (HS-20) 16,000 LB (SLAB-ON-GRADE, UON)

NOTE: LIVE LOAD REDUCTION WAS NOT USED IN THE DESIGN OF THIS STRUCTURE

2. SNOW LOADS:

GROUND SNOW LOAD, Pg 10 PSF

SNOW EXPOSURE FACTOR, Cₑ 0.9

THERMAL FACTOR, Ct 1.0

SNOW LOAD IMPORTANCE FACTOR, IS 1.0

FLAT ROOF SNOW LOAD, Pf 7 PSF

SLOPED-ROOF SNOW LOAD, PS 7 PSF

SLOPE FACTOR, CS 1.0

MINIMUM ROOF SNOW LOAD, Pm 10 PSF

RAIN-ON-SNOW SURCHARGE 5 PSF

3. WIND LOADS:

BASIC DESIGN WIND SPEED, V 130 MPH

ALLOWABLE STRESS DESIGN WIND SPEED, V(ASD) 101 MPH

RISK CATEGORY II

ENCLOSURE CLASSIFICATION PARTIALLY ENCLOSED

WIND EXPOSURE CATEGORY C

GUST EFFECT FACTOR, G 0.85

INTERNAL PRESSURE COEFFICIENTS, GCpi ±0.55

WIND BASE SHEAR VX=60K (PLAN EAST-WEST DIRECTION)

VY=120K(PLAN NORTH-SOUTH DIRECTION)

4. COMPONENTS AND CLADDING WIND PRESSURES:

USE WIND PRESSURES BELOW FOR THE DESIGN OF COMPONENT AND CLADDING ELEMENTS OR

RETAIN A PROFESSIONAL ENGINEER TO DETERMINE WIND PRESSURES FOR SPECIFIC EFFECTIVE

WIND AREAS.

DESIGN LOAD CRITERIA, CONTINUED:

5. SEISMIC LOADS:

RISK CATEGORY II

SEISMIC IMPORTANCE FACTOR, IE 1.0

SPECTRAL RESPONSE ACCELERATION, SS 0.088g SPECTRAL RESPONSE ACCELERATION, S1 0.040g SPECTRAL RESPONSE COEFFICIENT, SDS 0.094g SPECTRAL RESPONSE COEFFICIENT, SD1 0.064g

SITE CLASS D

SEISMIC DESIGN CATEGORY A

SEISMIC FORCE-RESISTING SYSTEM ORDINARY PRECAST SHEAR WALLS (A6)

RESPONSE MODIFICATION COEFFICIENT, R 3

DEFLECTION AMPLIFICATION FACTOR, Cd 3

SEISMIC RESPONSE COEFFICIENT, CS 0.01

OVERSTRENGTH FACTOR, Ωo 2.5 REDUNDANCY FACTOR, ρ 1.0

SEISMIC BASE SHEAR VX=50K (PLAN EAST-WEST DIRECTION)

VY=50K (PLAN NORTH-SOUTH DIRECTION)

ANALYSIS PROCEDURE EQUIVALENT LATERAL FORCE

STRUCTURAL PRECAST CONCRETE NOTES

1. DESIGN OF ALL PRECAST CONCRETE CONSTRUCTION IS DELEGATED TO THE CONTRACTOR’S SPECIALTY

STRUCTURAL ENGINEER. DESIGN PRECAST CONCRETE IN ACCORDANCE WITH PCI DESIGN HANDBOOK

(8TH EDITION, MNL 120-17) AND ACI 318-14.

2. THE PRECAST CONCRETE MANUFACTURER (PCM) SHALL BE RESPONSIBLE FOR THE DESIGN OF ALL PRECAST CONCRETE ELEMENTS SHOWN ON THE CONTRACT DOCUMENTS. DESIGN ALL ELEMENTS AND CONNECTIONS TO RESIST THE VERTICAL AND HORIZONTAL LIVE, DEAD, WIND, AND SEISMIC LOADINGS

INDICATED IN THE DESIGN NOTES ON THIS SHEET.

3. IN ADDITION TO LIVE LOADS STATED ON S-001T, DESIGN ALL PRECAST CONCRETE DOUBLE-TEES FOR THE

FOLLOWING LOADS:

A. DOUBLE-TEE SELF WEIGHT

B. TOPPING SELF WEIGHT

C. 10 PSF SUPERIMPOSED DEAD LOAD - APPLIED TO TOP OF DOUBLE TEE

D. 36 PSF SUPERIMPOSED DEAD LOAD - HUNG FROM DOUBLE-TEE RIBS

4. THE PCM SHALL BE RESPONSIBLE FOR THE DESIGN OF ALL LATERAL LOAD RESISTANCE OF THE PRECAST CONCRETE STRUCTURAL SYSTEM. THE LATERAL LOAD RESISTING SYSTEMS FOR THE BUILDING SHALL BE

AS FOLLOWS:

A. PRECAST CONCRETE WALLS SHALL ACT AS SHEAR WALLS. PROVIDE SHEAR CONNECTIONS BETWEEN WALL PANELS ALONG SAME COLUMN LINE WHERE INDICATED SO PANELS ACT AS A SINGLE SHEAR

WALL. SHEAR WALLS WILL PROVIDE ALL LATERAL LOAD RESISTANCE FOR THE BUILDING.

B. PRECAST CONCRETE DOUBLE-TEE AND CONCRETE TOPPING SHALL ACT AS THE HORIZONTAL

DIAPHRAGM. PROVIDE CHORD STEEL AND/OR CONNECTIVITY BETWEEN DOUBLE-TEES TO RESIST THE

APPLIED LATERAL LOADS.

C. THE PCM IS RESPONSIBLE FOR DESIGNING ALL PANEL TO FOUNDATION CONNECTIONS WHERE

LATERAL FORCES RESULT IN NET UPLIFT.

5. LIMIT DESIGN DEFORMATIONS OF PRECAST WALL PANELS TO PCI RECOMMENDATIONS AND AS FOLLOWS

(H = PANEL HEIGHT):

A. LATERAL DRIFT OF SHEAR WALL PANELS (IN-PLANE): H/480 (10-YEAR WIND)

B. HORIZONTAL DEFLECTION OF PANELS (OUT-OF-PLANE): H/240, 1 1/2” MAX

C. VERTICAL DEFLECTION OF PANELS OVER OPENINGS: L/600

D. RACKING OF PANELS: H/500

6. MANUFACTURE PRECAST CONCRETE WALL PANELS TO MEET THE PROFILE LINES, DIMENSIONS, REVEALS, AND JOINTS AS INDICATED. COORDINATE ROUGH OPENINGS WITH DOOR, WINDOW, AND LOUVER FRAME REQUIREMENTS. COORDINATE WITH OTHER TRADES FOR PENETRATIONS, ATTACHMENTS, INSERTS, AND

OTHER ITEMS TO BE CAST INTO OR ATTACHED TO WALL PANELS.

7. INDICATE ALL OPENINGS IN PRECAST CONCRETE WALL PANELS ON SHOP DRAWINGS. FIELD CUT

OPENINGS ARE NOT PERMITTED UNLESS SPECIFICALLY SHOWN ON THE SHOP DRAWINGS AND

ACCOUNTED FOR IN THE DESIGN BY THE PRECAST MANUFACTURER.

8. PRECAST MANUFACTURER MUST PROVIDE GUIDANCE AND LIMITATIONS ON FIELD-INSTALLED

PENETRATIONS AND ATTACHMENTS TO PRECAST PANELS. FIELD CUTTING, DRILLING, PENETRATING, AND

ANCHORING TO PANELS IS NOT PERMITTED WITHOUT APPROVAL OF PRECAST MANUFACTURER.

9. CONCRETE FOR PRECAST PANELS MUST BE NORMAL-WEIGHT, WITH MINIMUM 5000 PSI 28-DAY

COMPRESSIVE STRENGTH.

10. CONCRETE REINFORCING STEEL MUST BE DEFORMED BARS CONFORMING TO ASTM A615, GRADE 60.

11. CEMENT GROUT MUST BE NON-SHRINK, NON-METALLIC, WITH MINIMUM COMPRESSIVE STRENGTH OF

5000 PSI AT 28 DAYS.

12. ERECT PANELS TRUE TO LINE, LEVEL, AND PLUMB. LEVEL TO A TRUE PLANE WITH FULL BEARING ON SUPPORTING STRUCTURE. USE NON-SHRINK GROUT TO PROVIDE FULL UNIFORM BEARING AND MAINTAIN

LEVEL BASE ELEVATION.

13. PRESTRESSING STRAND SHALL BE UNCOATED, 7-WIRE, LOW-RELAXATION STRAND CONFORMING TO

ASTM A416/A416M, GRADE 270.

14. GALVANIZE ALL STEEL CONNECTION MATERIAL EXPOSED TO WEATHER OR BELOW GRADE.

15. DESIGN ALL PRECAST CONCRETE TO MEET THE FIRE RATING REQUIREMENTS INDICATED IN THE

CONTRACT DOCUMENTS.

16. COORDINATE ALL ARCHITECTURAL RECESSES, TEXTURES, OPENINGS, AND SIZES OF PRECAST CONCRETE

ELEMENTS WITH THE ARCHITECTURAL DRAWINGS.

17. VERIFY AND COORDINATE THE REQUIREMENTS OF THE STRUCTURAL DRAWINGS WITH THE DRAWINGS OF ALL OTHER DISCIPLINES INCLUDING, BUT NOT LIMITED TO, CIVIL, MECHANICAL, PLUMBING, AND

ELECTRICAL. PROVIDE ALL SLEEVES AND PENETRATIONS THROUGH THE PRECAST CONCRETE.

18. THE PCM SHALL ACCOUNT FOR VOLUMETRIC CHANGE STRAIN AND DEFORMATIONS DUE TO

TEMPERATURE CHANGES, SHRINKAGE, AND CREEP WHERE NECESSARY.

19. DESIGN AND PROVIDE ALL EMBEDDED ITEMS SHOWN ON THE CONTRACT DOCUMENTS TO RESIST THE

LOADS INDICATED. ALL LOADS INDICATED ARE SERVICE LOADS UNLESS OTHERWISE NOTED.

FOUNDATION NOTES

1. FOUNDATIONS HAVE BEEN DESIGNED IN ACCORDANCE WITH THE RECOMMENDATIONS IN THE

GEOTECHNICAL REPORT PREPARED BY ECS MID-ATLANTIC, LLC DATED JULY 10, 2023.

2. FOUNDATIONS HAVE BEEN DESIGNED TO BEAR ON UNDISTURBED, FIRM NATURAL SOIL OR ENGINEERED FILL AND GROUND IMPROVEMENT PROGRAM CONSISTING OF RIGID INCLUSION AS INDICATED IN THE

GEOTECHNICAL REPORT WITH A NET ALLOWABLE BEARING CAPACITY OF 4000 PSF.

3. PRIOR TO PLACING FOUNDATION CONCRETE, AN INDEPENDENT TESTING LABORATORY AND

GEOTECHNICAL ENGINEER REGISTERED IN VIRGINIA MUST INSPECT FOUNDATION EXCAVATIONS TO EVALUATE THE EXTENT OF LOOSE, SOFT OR OTHERWISE UNSATISFACTORY SOIL MATERIAL AND TO VERIFY THE BEARING CAPACITY. SOILS NOT SUITABLE FOR FOUNDATION SUPPORT MUST BE UNDERCUT

AND REPLACED WITH ENGINEERED FILL.

4. MINIMUM SUBGRADE PREPARATIONS ARE AS INDICATED IN THE GEOTECHNICAL REPORT.

5. ADEQUATELY PROTECT FOUNDATION EXCAVATIONS TO PREVENT WATER FROM ACCUMULATING AND STANDING IN THE EXCAVATION BOTTOMS. DO NOT PLACE FOUNDATION CONCRETE ON FROZEN OR

SATURATED SUBGRADES.

6. ENSURE THAT EARTH-FORMED FOOTINGS CONFORM TO THE SHAPE, LINES AND THICKNESSES INDICATED

ON THE FOUNDATION PLAN.

7. PLACE FOUNDATION CONCRETE THE SAME DAY EXCAVATIONS ARE MADE OR AS SOON AS PRACTICAL

THEREAFTER.

8. DO NOT INSTALL FOUNDATIONS UNTIL FOUNDATION WORK HAS BEEN COORDINATED WITH ADJACENT UNDERGROUND UTILITIES AND STRUCTURES. ANY FOOTING STEPS INDICATED ON PLAN ARE SCHEMATIC

AND MUST BE COORDINATED WITH OTHER TRADES.

9. CONTINUOUS FOOTINGS MUST BE LOWERED AS REQUIRED TO PASS UNDER UTILITY LINES. STEP CONTINUOUS FOOTINGS DOWN AS SHOWN IN THE “TYPICAL STEPPED FOOTING” DETAIL ON SHEET SB501T.

IN LIEU OF STEPPED FOOTINGS, PIPE SLEEVES BELOW CONTINUOUS FOOTINGS MAY BE PROVIDED IN ACCORDANCE WITH THE “TYPICAL PIPE SLEEVE BENEATH FOOTING” DETAIL ON SHEET SB501T.

Y

X

Z

APPLIED FORCE COORDINATE

SYSTEM FOR CONNECTIONS

NOTES:

A. POSITIVE AND NEGATIVE SIGNS SIGNIFY PRESSURES ACTING TOWARD AND AWAY

FROM THE SURFACES, RESPECTIVELY.

B. BUILDING ZONES ARE DEFINED IN ASCE 7. ZONE 2 ROOF WIND LOADS APPLY IN ZONE

3 AREAS WHERE PARAPET HEIGHT EXCEEDS 3 FEET.

C. WIND PRESSURES INDICATED ARE AT STRENGTH-LEVEL (WIND LOAD FACTOR = 1.0).

D. DESIGN WIND PRESSURES FOR DEFLECTION-CONTROLLED COMPONENTS AND

CLADDING MAY UTILIZE A 10-YEAR MEAN RECURRENCE INTERVAL.

DESIGN WIND PRESSURE FOR

ROOF COMPONENTS (PSF)

1 - 100

ROOF ZONE

101+

COMPONENT TRIBUTARY AREA (FT2)

+24 -40 -40

-62 -50

-78 -64

1'

+21

DESIGN WIND PRESSURE FOR

WALL COMPONENTS (PSF)

1 - 100

WALL ZONE

101+

COMPONENT TRIBUTARY AREA (FT2)

+40 -42 -38

-50 -415

+36

+36

+40

DESIGN WIND PRESSURE FOR

PARAPETS (PSF)

ALOAD CASE B

COMPONENT

TRIBUTARY AREA (FT2)

+92 +73 +45

+81 +455

+67

+59

+117

WALL ZONE

COMPONENT

TRIBUTARY AREA (FT2)

0 - 100 101+ 101+0 - 100

-103 -743

+24 +21

+24 +21

+24 +21

VIRGINIA BEACH, VIRGINIA 23462

4525 MAIN STREET, SUITE 1400

757·455·5800

1 2 3 4 5 6

A

B

C

D

E

SHEET

B

C

D

E

DESIGN:

DRAWN:

REVIEW:

REVISIONSDESIGNER

A

PROFESSIONAL SEAL

NOT F

OR C

ONSTRUCTIO

N

5032 ROUSE DRIVE, SUITE 200

VIRGINIA BEACH, VA 23462-3764

757.490.9264

CIVIL CONSULTANT

C U s e rs \S

S M

IT

H

\D o c u m e n ts \R e v it P ro je c ts

\2

\1

P o rt s m o u th

C o m p le x R a n g e

S s s m it h Z

C

M Y

.r v t

/1

/2

:5

:0

P

M

TRAINING STRUCTURAL NOTES

SSD

SMS

LSS

CN 1020535% SUBMITTAL DOCUMENTS

JANUARY 16, 2024

PORTSMOUTH PUBLIC SAFETY COMPLEX

CITY OF PORTSMOUTH

3701 WILLETT DR

PORTSMOUTH, VA 23707

S-001T

'-8

108'-9" 93'-3"

202'-0"

'-4

WF3.0

W F

3.

WF3.0

WF3.0

W F

3.

W F

3.

WF3.0

VIRGINIA BEACH, VIRGINIA 23462

4525 MAIN STREET, SUITE 1400

757·455·5800

1 2 3 4 5 6

A

B

C

D

E

SHEET

B

C

D

E

DESIGN:

DRAWN:

REVIEW:

REVISIONSDESIGNER

A

PROFESSIONAL SEAL

NOT F

OR C

ONSTRUCTIO

N

5032 ROUSE DRIVE, SUITE 200

VIRGINIA BEACH, VA 23462-3764

757.490.9264

CIVIL CONSULTANT

C U s e rs \S

S M

IT

H

\D o c u m e n ts \R e v it P ro je c ts

\2

\1

P o rt s m o u th

C o m p le x R a n g e

S s s m it h Z

C

M Y

.r v t

/1

/2

:5

:0

P

M

TRAINING FOUNDATION PLAN

SSD

SMS

LSS

CN 1020535% SUBMITTAL DOCUMENTS

JANUARY 16, 2024

PORTSMOUTH PUBLIC SAFETY COMPLEX

CITY OF PORTSMOUTH

3701 WILLETT DR

PORTSMOUTH, VA 23707

SB101T

1/8" = 1' - 0" 0 5' 10' 15' 30'

GRAPHIC SCALE(S)

FOUNDATION PLAN NOTES

# KEY NOTES

SCALE: 1/8" = 1'-0"

A1

FOUNDATION PLAN

1. TOP OF SLAB-ON-GRADE IS DATUM ELEVATION [0'-0"], UNLESS

OTHERWISE NOTED.

2. TOP OF FOOTING ELEVATION IS [-2'-0"], UNLESS OTHERWISE NOTED.

3. WALL FOOTINGS ARE INDICATED 'WFx' ON PLAN. REFER TO 'FOOTING

SCHEDULE' ON SHEET SB501T FOR SIZE AND REINFORCING. WALL

FOOTINGS ARE LOCATED AT THE CENTERLINES OF WALLS, UNLESS

OTHERWISE NOTED.

4. SLAB-ON-GRADE IS 6" THICK CONCRETE REINFORCED WITH

6x6-W2.9xW2.9 WWR OVER VAPOR RETARDER OVER 4" OF POROUS FILL, UNLESS OTHERWISE NOTED. REFER TO TYPICAL SLAB-ON-GRADE

DETAILS ON SHEET SB501T.

5. SLAB-ON-GRADE CONTRACTION OR CONSTRUCTION JOINT SPACING

MUST NOT EXCEED 15'-0" SPACING AND PANEL ASPECT RATIO MUST NOT

EXCEED 1:1.5. SUBMIT JOINT LAYOUT PLAN FOR APPROVAL 2 WEEKS

PRIOR TO PLACING SLAB-ON-GRADE CONCRETE.

6. COORDINATE ALL FOOTING LOCATIONS WITH CIVIL, PLUMBING AND

ELECTRICAL DRAWINGS. FOOTINGS MUST BE LOWERED AS NECESSARY

TO PASS UNDER UTILITY LINES ACCORDING TO 'TYPICAL STEPPED

FOOTING' DETAIL ON SHEET SB501T. CONTRACTOR MAY PROVIDE PIPE

SLEEVES BELOW FOOTING IN LIEU OF STEPPED FOOTING IF THE

DIMENSIONAL REQUIREMENTS IN THE TYPICAL DETAIL ON SHEET SB501T

ARE MET.

PAVING OR

FINISHED GRADE,

SEE CIVIL DWGS

CONCRETE

SLAB-ON-GRADE

1/2" PJF

CONCRETE FOOTING,

SEE PLAN AND SCHEDULE

ON THIS SHEET

NON-SHRINK GROUT

PRECAST CONCRETE

WALL PANEL, SEE PLAN

CL WALL PANEL

AND FOOTING

DETAIL 'A'

NOTES:

1. PAINT STEEL BELOW GRADE WITH

TWO (2) COATS OF COAL TAR EPOXY.

2. DETAIL SIMILAR AT INTERIOR WALL.

3" CLR,

TYP

GRID

[SEE PLAN]

TOF

[SEE PLAN]

TOC

ANGLE AND

POST-INSTALLED

STRUCTURAL

ANCHOR BY PCM

3 SIDESPANEL SHEAR

CONNECTION

BY PCM

DETAIL 'A'

2" G

R O

U T

T H

IC

K

N E

S S

V

A R

IE

S

PAVING, SEE

CIVIL DWGS

1'-4"

2" CLR

SEE ARCH DWGS

WALL OPENING

PLAN

#4 AT 12" OC TOP

(3 BARS MIN)

12" LAP MIN

CONCRETE

SLAB-ON-GRADE

SECTION

(1) #4 AT RE-ENTRANT

CORNER, MIDDLE OF

SLAB, EACH SIDE

(1) #5 CONT, TOP

EDGE OF

SLAB (EOS)

0"

3' -0

1'-0"

3/4" CLR

CL FOOTING AND

WALL PANEL

FACE OF WALL PANEL

AND TURN-DOWN

WALL PANEL (TYP)

SLOPE

CONCRETE SLAB-ON-GRADE

CONCRETE FOOTING,

SEE PLAN AND SCHEDULE

ON THIS SHEET

#4 AT 24" OC WITH

STD 90° HOOK

(2) #5 CONT,

BOTTOM

PRECAST CONCRETE

WALL PANEL BEYOND

[SEE PLAN]

TOF

[SEE PLAN]

TOC

1/2" PFJ

PLAN AT

INTERSECTION

PLAN AT

CORNER

SEE FOOTING

SCHEDULE ON

SHEET S____ FOR

REINFORCING (TYP)

NOTES:

1. WHERE THREE BARS

OCCUR, CENTER BAR

SHALL BE TREATED

AS AN INNER FACE BAR.

2. 'B' AND 'D' BARS NOT

SHOWN FOR CLARITY.

3' -0

TYP

1'-6"

3'-0"

0", TYP

1'-6" 1'-6"

0" , T

Y P

8" STEP

16" MIN FOR

16" STEP

32" MIN FOR 3" CLR, TYP

1'-0" MIN

CONTINUOUS WALL

FOOTING REINFORCING,

SEE SCHEDULE

ON THIS SHEET

'Z' BARS SAME SIZE AND

NUMBER AS CONTINUOUS

FOOTING REINFORCING,

BEND AS SHOWN

'A' BARS

'B' BARS

CONTINUOUS WALL

FOOTING REINFORCING

8" M

IN

M A

X

TYP

36 BD LAP

CONTINUOUS WALL

FOOTING, SEE PLAN

AND SCHEDULE

PVC OR GALVANIZED

STEEL PIPE SLEEVE.

(Ø = PIPE Ø + 2" MIN)

1'-0" M

IN, TYP

8" MIN

1500 PSI LEAN CONCRETE,

WIDTH EQUAL TO

CONTINUOUS FOOTING WIDTH

M

IN

M A

X

SECTION

WALL

'B' BARS'A' BARS

'D' BARS'C' BARS

W

T 'A' AND

'C' BARS CONT

'B' AND

'D' BARS

O

N T

PLAN

WALL

W

NOTE:

FOOTINGS ARE CENTERED

BENEATH WALL UNLESS

OTHERWISE NOTED.

BOTTOM REINFORCING

CONTINUOUS

THROUGH JOINT

TIE BAR EACH SIDE OF

CONSTRUCTION JOINT

2" C

LR

T

O P

(3) #5 x4'-0" TOP

CENTERED ON JOINT

S E

E P

LA

N

T

PREVIOUS POUR NEW POUR

T/

T/

T/

4" 4"

SUPPORTS FOR

REINFORCEMENT AT

3'-0" OC EACH WAY, MAX

CONCRETE SLAB-ON-GRADE

POROUS FILL

[SEE PLAN]

TOC

SEE PLAN

VAPOR RETARDER

SLAB REINFORCEMENT,

SEE PLAN

U O

N CONCRETE

SLAB-ON-GRADE

SAWCUT JOINT, DEPTH

EQUAL TO 1/4 OF

SLAB THICKNESS

[SEE PLAN]

TOC

SEE PLAN

SLAB REINFORCEMENT,

SEE PLAN

2x4 CONT KEY

APPLY LIQUID CURING

COMPOUND TO ENTIRE

FACE OF PREVIOUS POUR

TO PREVENT BONDING

SLAB REINFORCEMENT,

SEE PLAN

PREVIOUS POUR

CONCRETE

SLAB-ON-GRADE

2" CLR, TYP

6"

8" 6" 6" 8"

[SEE PLAN]

TOC

MIN

1'-0"

SLAB REINFORCEMENT,

SEE PLAN

[SEE PLAN]

TOC

CONCRETE

SLAB-ON-GRADE

SEE PLAN FOR

DEPTH OF SLAB

DEPRESSION

(2" MAX) 1

1/ 2"

U O

N

VIRGINIA BEACH, VIRGINIA 23462

4525 MAIN STREET, SUITE 1400

757·455·5800

1 2 3 4 5 6

A

B

C

D

E

SHEET

B

C

D

E

DESIGN:

DRAWN:

REVIEW:

REVISIONSDESIGNER

A

PROFESSIONAL SEAL

NOT F

OR C

ONSTRUCTIO

N

5032 ROUSE DRIVE, SUITE 200

VIRGINIA BEACH, VA 23462-3764

757.490.9264

CIVIL CONSULTANT

C U s e rs \S

S M

IT

H

\D o c u m e n ts \R e v it P ro je c ts

\2

\1

P o rt s m o u th

C o m p le x R a n g e

S s s m it h Z

C

M Y

.r v t

/1

/2

:5

:0

P

M

TRAINING TYPICAL FOUNDATION DETAILS

SSD

SMS

LSS

CN 1020535% SUBMITTAL DOCUMENTS

JANUARY 16, 2024

PORTSMOUTH PUBLIC SAFETY COMPLEX

CITY OF PORTSMOUTH

3701 WILLETT DR

PORTSMOUTH, VA 23707

SB501T

NOT TO SCALE

C1

TYPICAL FOUNDATION DETAIL AT EXTERIOR PRECAST WALL

NOT TO SCALE

A1

TYPICAL SLAB AT EXTERIOR OPENING

FOOTING SCHEDULE

MARK

DIMENSIONS REINFORCING

NOTESW T 'A' BARS 'B' BARS 'C' BARS 'D' BARS

WF3.0 3'-0" 1'-6" - - - -

NOT TO SCALE

D2

TYPICAL CONTINUOUS

FOOTING REINFORCING

NOT TO SCALE

D5

TYPICAL STEPPED FOOTING

NOT TO SCALE

D6

TYPICAL PIPE SLEEVE

BENEATH FOOTING

NOT TO SCALE

D1

TYPICAL WALL FOOTING

REINFORCING DIAGRAMS

NOT TO SCALE

D4

TYPICAL CONCRETE FOOTING

CONSTRUCTION JOINT

NOT TO SCALE

B1

TYPICAL SLAB-ON-GRADE (SOG)

NOT TO SCALE

B2

TYPICAL SLAB-ON-GRADE

SAWED (CONTRACTION) JOINT (SJ)

NOT TO SCALE

B3

TYPICAL SLAB-ON-GRADE

CONSTRUCTION JOINT (CJ)

NOT TO SCALE

B4

TYPICAL SLAB DEPRESSION (SD)

S

S L

S L

'-8

108'-9" 93'-3"

'-4

TOC

[+21'-2"]

TOC

[+21'-2"]

TOW

[+21'-10"]

TOW

[+21'-10"]

TOC

[+20'-0"]

TOC

[+20'-0"]

TOW

[+21'-10"]

TOW

[+21'-10"]

TOC

[+20'-8"]

VIRGINIA BEACH, VIRGINIA 23462

4525 MAIN STREET, SUITE 1400

757·455·5800

1 2 3 4 5 6

A

B

C

D

E

SHEET

B

C

D

E

DESIGN:

DRAWN:

REVIEW:

REVISIONSDESIGNER

A

PROFESSIONAL SEAL

NOT F

OR C

ONSTRUCTIO

N

5032 ROUSE DRIVE, SUITE 200

VIRGINIA BEACH, VA 23462-3764

757.490.9264

CIVIL CONSULTANT

C U s e rs \S

S M

IT

H

\D o c u m e n ts \R e v it P ro je c ts

\2

\1

P o rt s m o u th

C o m p le x R a n g e

S s s m it h Z

C

M Y

.r v t

/1

/2

:5

:0

P

M

TRAINING ROOF FRAMING PLAN

SSD

SMS

LSS

CN 1020535% SUBMITTAL DOCUMENTS

JANUARY 16, 2024

PORTSMOUTH PUBLIC SAFETY COMPLEX

CITY OF PORTSMOUTH

3701 WILLETT DR

PORTSMOUTH, VA 23707

SF101T

1/8" = 1' - 0" 0 5' 10' 15' 30'

GRAPHIC SCALE(S)

FRAMING PLAN NOTES

# KEY NOTES

SCALE: 1/8" = 1'-0"

A1

ROOF FRAMING PLAN

1. ROOF ELEVATIONS ARE REFERENCED FROM FINISHED FIRST FLOOR

ELEVATION = [0'-0"].

2. ROOF STRUCTURE IS 28" DEEP, 12'-0" WIDE PRECAST PRESTRESSED

CONCRETE DOUBLE TEES WITH 2" MINIMUM TOPPING SLAB, REFER TO

"TYPICAL CONCRETE TOPPING THICKNESS" ON SHEET SF501T.

PRECAST MANUFACTURER TO ADJUST LAYOUT OF DOUBLE TEES AS

NEEDED TO ACCOMMODATE ATYPICAL WIDTHS. TOP SURFACE OF

DOUBLE TEE DECK MUST BE ROUGHENED TO 1/4" AMPLITUDE TO BOND

TOPPING.

PRECAST

CONCRETE

WALL PANEL,

SEE PLAN

CONTINUOUS

BACKER ROD

AND SEALANT

AT 1" JOINT

PRECAST CONCRETE

DOUBLE-TEE, SEE PLAN

BEARING PAD

PRECAST CONCRETE

CORBEL BY PCM

2" MIN TOPPING SLAB WITH

6x6-W4.0x4.0 WWR

CHORD STEEL AT PERIMETER TYPICAL

AS REQUIRED FOR LATERAL DIAPHRAGM

DESIGNED AND DETAILED BY PCM.

COORDINATE SIZE AND LOCATION OF

CHORD STEEL WITH CAST-IN-PLACE

CONCRETE CONTRACTOR.

1" PJF, CONT

GRID

SLOPE

PCM TO PROVIDE LATERAL FORCE

RESISTING SYSTEM CONNECTIONS

AS REQUIRED TO MEET PERFORMANCE

CRITERIA FOR DESIGN LOADS IN THE

"DESIGN NOTES" ON SHEET S-001T.

PRECAST CONCRETE

DOUBLE-TEE, SEE PLAN

2" MIN TOPPING SLAB WITH

6x6-W4.0x4.0 WWR

CHORD STEEL AT PERIMETER TYPICAL

AS REQUIRED FOR LATERAL DIAPHRAGM

DESIGNED AND DETAILED BY PCM.

COORDINATE SIZE AND LOCATION OF

CHORD STEEL WITH CAST-IN-PLACE

CONCRETE CONTRACTOR.

1" PJF, CONT

PRECAST

CONCRETE

WALL PANEL,

SEE PLAN

CONTINUOUS BACKER

ROD AND SEALANT

AT 1" JOINT

GRID

PCM TO PROVIDE LATERAL FORCE

RESISTING SYSTEM CONNECTIONS

AS REQUIRED TO MEET PERFORMANCE

CRITERIA FOR DESIGN LOADS IN THE

"DESIGN NOTES" ON SHEET S-001T.

[VARIES]

TOC

[SEE PLAN]

TOW

[SEE PLAN]

TOC

[SEE PLAN]

TOW

PERPENDICULAR TO WALL PANEL PARALLEL TO WALL PANEL

ROOFING, SEE ARCH DWGS

ROOFING, SEE ARCH DWGS

SF501T

D3

3 SIDES

VIRGINIA BEACH, VIRGINIA 23462

4525 MAIN STREET, SUITE 1400

757·455·5800

1 2 3 4 5 6

A

B

C

D

E

SHEET

B

C

D

E

DESIGN:

DRAWN:

REVIEW:

REVISIONSDESIGNER

A

PROFESSIONAL SEAL

NOT F

OR C

ONSTRUCTIO

N

5032 ROUSE DRIVE, SUITE 200

VIRGINIA BEACH, VA 23462-3764

757.490.9264

CIVIL CONSULTANT

C U s e rs \S

S M

IT

H

\D o c u m e n ts \R e v it P ro je c ts

\2

\1

P o rt s m o u th

C o m p le x R a n g e

S s s m it h Z

C

M Y

.r v t

/1

/2

:5

:0

P

M

TRAINING TYPICAL FRAMING DETAILS

SSD

SMS

LSS

CN 1020535% SUBMITTAL DOCUMENTS

JANUARY 16, 2024

PORTSMOUTH PUBLIC SAFETY COMPLEX

CITY OF PORTSMOUTH

3701 WILLETT DR

PORTSMOUTH, VA 23707

SF501T

NOT TO SCALE

D1

TYPICAL PRECAST DOUBLE-TEE TO WALL PANEL CONNECTION

NOT TO SCALE

D3

DETAIL

AND&

EXIST EXISTING

VINYL COMPOSITION TILEVCT

AFS

ADJ

AT

APPROX

AFF

BD

ALUM

APPROXIMATE

BOARD

ABOVE FINISH FLOOR

ABOVE FINISH SLAB

ALUMINUM

ADJUSTABLE, ADJUST

CEILING

COL

CLG

DIA

CMU

CONC

DOWNDN

EQUIP

ELEC

ELEV

EQUIPMENT

ELECTRICAL

ELEVATION

CONCRETE MASONRY UNIT

CONCRETE

DIAMETER

COLUMN

FLOOR

FO

FLR

GWB GYPSUM WALLBOARD

FACE OF

EQ EQUAL

CENTER LINE

HORIZ HORIZONTAL

TYPICALTYP

TOC TOP OF CONCRETE

WIDTH / WASHER

VERT

W

VERTICAL

UNLESS OTHERWISE NOTEDUON

HOLLOW METALHM

VIF VERIFY IN FIELD

CL

ALT ALTERNATE

APC ARCHITECTURAL PRECAST CONCRETE

ACT ACOUSTICAL CEILING TILE

BLDG BUILDING

BLKG BLOCKING

BRG BEARING

BUR BUILT-UP ROOFING

CORNER GUARDCG

CONTROL JOINTCJ

CLEARCLR

CONST CONSTRUCTION

CONT CONTINUOUS

CPT CARPET

CT CERAMIC TILE

D DEPTH / DRYER

DBL DOUBLE

DIAG DIAGONAL

DIM DIMENSION

DISP DISPENSER

DOWNSPOUTDS

DRAWINGDWG

EACHEA

EXPANSION JOINTEJ

EDGE OF SLABEOS

EPS EXPANDED POLYSTYRENE

EXP EXPANSION / EXPOSED

EXT EXTERIOR

FD FLOOR DRAIN

FEB FIRE EXTINGUISHER BRACKET

FEC FIRE EXTINGUISHER CABINET

FGL FIBERGLASS

FF FINISH FLOOR

FIN FINISH

FRT FIRE RETARDANT TREATED

GA GAUGE

GALV GALVANIZED

GFRG GLASS FIBER REINFORCED GYPSUM

GL GLASS

GYP GYPSUM

HDW HARDWARE

HDWD HARDWOOD

HT HEIGHT

HVAC HEATING, VENTILATION, & AIR

CONDITIONING

ID INSIDE DIAMETER

INSUL INSULATION

INT INTERIOR

JT JOINT

L LENGTH / LONG

MATL MATERIAL

SUSPENDEDSUSP

THR THRESHOLD

TOW TOP OF WALL

TP TOILET PARTITION

TOP & BOTTOMT & B

VINYL BASEVB

VTR VENT THRU ROOF

WITHW/

WITHOUTW/O

WALLCOVERINGWC

WOODWD

WINDOWWDW

WINDOW OPENINGWO

WORK POINTWP

WEIGHTWT

EXTRUDED POLYSTYRENEXPS

METALMTL

NIC

MISC

OC

MISCELLANEOUS

ON CENTER

NOT IN CONTRACT

ROOM

SIMILAR

R

RM

REF

SIM

RO

SS

RADIUS

STAINLESS STEEL

ROUGH OPENING

REFRIGERATORMAX MAXIMUM

MECH MECHANICAL

MFR MANUFACTURER

MIN MINIMUM

MO MASONRY OPENING

MTG MOUNTING

NO NUMBER

NOM NOMINAL

NTS NOT TO SCALE

OD OUTSIDE DIAMETER

OFCI OWNER FURNISHED

OFOI OWNER FURNISHED

OH OPPOSITE HAND

OPNG OPENING

OPP OPPOSITE

ORD OVERFLOW ROOF DRAIN

PL PLATE

PLAM PLASTIC LAMINATE

PLYWD PLYWOOD

PR PAIR

PTD PAINTED

RD ROOF DRAIN

REINF REINFORCING

REQ'D REQUIRED

RWL RAIN WATER LEADER

SAFB SOUND ATTENUATING FIRE BLANKET

SF SQUARE FEET

SQUARESQ

STRUCTURALSTRUCT

STD STANDARD

STL STEELCONTRACTOR INSTALLED

OWNER INSTALLED

TTL TOTAL

PH PANIC HARDWARE

KO KNOCK OUT

GC GENERAL CONTRACTOR

IGU INSULATING GLASS UNIT

POLYISO POLYISOCYANURATE

INSULATION

SAB SOUND ATTENUATING BLANKET

FP FIRE PROTECTION

TELE TELECOMMUNICATION

BSJ BUILDING SEPARATION JOINT

COLUMN LINECL

CONCRETE WOOD BLOCKING - INTERRUPTED

BRICK

CONCRETE MASONRY UNIT (CMU)

INSULATION - BATT / LOOSE / BLANKET

PLYWOOD / MDF

EARTH

INSULATION - MINERAL WOOL

SPANDREL GLAZING

WOOD BLOCKING / FRAMING -

CONTINUOUSINSULATION - RIGID

GRAVEL INSULATION - SPRAY FOAM

GWB / GROUT / SPRAY FIREPROOFING

STEELALUMINUM FILL - GRANULAR

FILL - POROUS

A

XX.X

DIRECTION OF SLOPE

ROOF SLOPE

FLOOR DRAIN

FIRE EXTINGUISHER CABINET

FIRE EXTINGUISHER BRACKET

FD

WINDOW / LOUVER / CURTAIN WALL / STOREFRONT

DESIGNATION

FEC

FEB

W1 L1 C1 S1

SPECIALTY ITEM DESIGNATION

PARTITION / WALL TYPE

DOOR NUMBER

CJ BSJ EJ

CONTROL

JOINT

EXPANSION

JOINT

BUILDING

SEPARATION JOINT

REFER TO THE GENERAL "G" SERIES SHEETS FOR

GENERAL PROJECT SYMBOLOGY

2' x 2' ACOUSTICAL

TILE LAY-IN CEILING

GWB

CEILING / SOFFIT

METAL PANEL

CEILING / SOFFIT

4' x 4' ACOUSTICAL

TILE LAY-IN CEILING

OS

S

H P

LIGHT FIXTURES

CEILING MOUNTED

EXIT LIGHT

FIRE ALARM STROBE

CEILING MOUNTED

OCCUPANCY SENSOR

CARBON MONOXIDE DETECTOR

HEAT DETECTOR

SMOKE DETECTOR

CEILING HEIGHT EXPOSED CEILING

SPRINKLER HEAD

CEILING MOUNTED

RECEPTACLE

CO

8'-0"

S

S

EXP

SUPPLY GRILLE

V F

EXHAUST FAN

CEILING MOUNTED

SECURITY CAMERA

ACCESS PANEL CEILING FAN

2' x 4' ACOUSTICAL

TILE LAY-IN CEILING

CEILING MOUNTED

EXIT LIGHT W/ ARROW

EMERGENCY EGRESS LIGHT FIXTURES

INDICATES BRACKET, WALL MOUNTED

ELECTRICAL LIGHT / FIXTURE / EQUIPMENT, ETC

INDICATES BRACKET, WALL MOUNTED

FIRE PROTECTION FIXTURE / EQUIPMENT, ETC

WOOD

CEILING / SOFFIT

PHOTO DETECTOR

SPEAKER SPEAKER W/ STROBE

FIRE ALARM HORN STROBE

RETURN GRILLE

1. PLAN DIMENSIONS SHOWN ARE TO FACE OF FRAMING MEMBERS, FACE OF MASONRY, FACE OF EXISTING WALL AND TO

CENTERLINE OF COLUMNS.

2. ALL NOTES, DETAILS, AND FEATURES DRAWN AS APPLICABLE FOR ONE CONDITION ARE APPLICABLE TO SIMILAR

CONDITIONS, WHETHER OR NOT SPECIFICALLY INDICATED.

3. IN STUD WALLS, LOCATE ALL INTERIOR DOOR FRAMES A DISTANCE OF 4" (FOUR) INCHES FROM THE THROAT RETURN TO THE CLOSEST ADJACENT PERPENDICULAR PARTITION, UON. IN CMU WALLS, LOCATE MASONRY OPENING AT DOORS 8"

(EIGHT) FROM THE PERPENDICULAR WALL.

4. ALL ELEVATIONS ARE MEASURED FROM THE REFERENCE ELEVATION +0'-0", WHICH IS THE TOP OF THE FIRST FLOOR

SLAB, UON.

5. DO NOT SCALE DRAWINGS TO DETERMINE DIMENSIONS OR SIZES OF BUILDING ELEMENTS.

6. ALL WOOD BLOCKING AND MISCELLANEOUS STEEL SHOWN IN DETAILS AND SECTIONS SHALL BE CONTINUOUS, UON.

7. USE FIRE-RETARDANT TREATED WOOD PRODUCTS FOR ALL CONCEALED WOOD BLOCKING, UON.

8. USE PRESERVATIVE-TREATED WOOD PRODUCTS FOR ALL WOOD BLOCKING IN CONTACT WITH EXTERIOR MASONRY OR CONCRETE WALLS, AND FOR ALL WOOD BLOCKING IN CONTACT WITH CONCRETE SLABS ON GRADE.

9. VERIFY ALL DIMENSIONS. BRING ANY DISCREPANCIES TO THE IMMEDIATE ATTENTION OF THE ARCHITECT.

10. ANY CONFLICTING INFORMATION BETWEEN THE ARCHITECTURAL DRAWINGS AND ANY OTHER DRAWINGS, SPECIFICATIONS, AND/OR EXISTING CONDITIONS SHALL BE NOTED IN WRITING TO THE ARCHITECT FOR REVIEW AND

MUST BE CLARIFIED PRIOR TO COMMENCING THE CONSTRUCTION IN QUESTION.

11. PROVIDE WOOD OR METAL BLOCKING BEHIND GWB AT THE FOLLOWING LOCATIONS:

A. ALL WALL-MOUNTED OR CEILING-MOUNTED DOOR STOPS, DOOR HOLD-OPEN DEVICES, AND OTHER HARDWARE.

B. ALL WALL-MOUNTED TOILET ACCESSORIES. AT GRAB BARS, PROVIDE BLOCKING CAPABLE OF RESISTING A MINIMUM LOAD OF 250 POUNDS APPLIED VERTICALLY OR HORIZONTALLY AT ANY POINT ON THE GRAB BAR.

C. ALL WALL-MOUNTED PLUMBING FIXTURES, INCLUDING BUT NOT LIMITED TO LAVATORIES, SINKS, URINALS, WATER CLOSETS, AND WATER COOLERS. PROVIDE BLOCKING CAPABLE OF RESISTING A MINIMUM LOAD OF 400 POUNDS

APPLIED VERTICALLY AT ANY POINT ON THE PLUMBING FIXTURE.

D. ALL WALL-MOUNTED CABINETRY, SHELVING, AND SIMILAR ITEMS.

E. ALL WALL-MOUNTED VIDEO MONITORS, AND SIMILAR ITEMS.

12. ALL MATERIALS USED IN THE PROJECT SHALL BE NEW AND PROVIDED BY THE CONTRACTOR, UON.

13. USE BITUMINOUS MEMBRANE TO SEPARATE PRESERVATIVE-TREATED WOOD PRODUCTS FROM CONTACT WITH ANY

METAL SURFACE.

VIRGINIA BEACH, VIRGINIA 23462

4525 MAIN STREET, SUITE 1400

757·455·5800

1 2 3 4 5 6

A

B

C

D

E

SHEET

B

C

D

E

DESIGN:

DRAWN:

REVIEW:

REVISIONSDESIGNER

A

PROFESSIONAL SEAL

NOT F

OR C

ONSTRUCTIO

N

5032 ROUSE DRIVE, SUITE 200

VIRGINIA BEACH, VA 23462-3764

757.490.9264

CIVIL CONSULTANT

C U s e rs

\B G

U R

C Z

Y N

S K

I\ O n e D ri v e

C la rk N e x s e n \D o c u m e n ts

\1

P o rt s m o u th C o m p le x H

Q A b g u rc z y n s k i_

C la rk N e x s e n c o m

.r v t

/1

/2

:1

:3

P

M

ARCHITECTURAL LEGEND, NOTES AND

ABBREVIATIONS

Designer

Author

Checker

CN 1020535% SUBMITTAL DOCUMENTS

JANUARY 16, 2024

PORTSMOUTH PUBLIC SAFETY COMPLEX

CITY OF PORTSMOUTH

3701 WILLETT DR

PORTSMOUTH, VA 23707

A-001

ARCHITECTURAL GENERAL NOTES

ARCHITECTURAL ABBREVIATIONS

ARCHITECTURAL SYMBOLOGY

MATERIAL LEGENDRATED PARTITION LEGEND

RCP LEGEND

NOT ALL ABBREVIATIONS, SYMBOLS, AND

LEGEND GRAPHICS LISTED ARE NECESSARILY

USED ON THIS PROJECT. REFER TO

DOCUMENTS FOR SPECIFIC INFORMATION.

TWO HOUR FIRE RATING

ONE HOUR FIRE RATING

E

LE

C T

R

IC

A L

F

IR

E P

R O

T E

C T

IO

N

A R

C H

IT

E

C T

U R

A L

M E

C H

A N

IC

UP

W D

AE201H

A1

AE201H

C1

AE201H

B1

AE201H

D1

96'-0"

'-0

'-0

'-0

'-0

19'-10"

20'-0"

85'-0"

'-1

/8

20'-0"

AE203H

D1

AE101H

AE102H

AE101H

AE102H

A E

3H

A E

2H

A E

3H

A E

2H

AE103H

AE104H

AE103H

AE104H

AE202H

D1

AE202H

C6

AE203H

C1

AE203H

C4

AE203H

A5

AE204H

D2

AE204H

D1

AE204H

B2

AE204H

C1

AE202H

A1

AE202H

C1

H1002

H1014

H1009

H1021

ST2

ELV 1

H1121

H1110

H1106

H1042

H1046

H1111

H1038

H1116

H1028

H1100

ELV 2

H1202

H1204

H1218

H1209

H1220

H1223

H1222

H1246

H1247

H1248

ELV 3

ST3

H1302H1301

H1300

H1304 H1303

H1305

H1306

H1040

H1041

H1250

H1310

H1104

H1022

H1010

H1207

H1211

H1112

H1018

H1039

H1241 H1214

H1215

H1212 H1213

H1210

H1238

H1227

H1224

H1234 H1226

H1232

H1237H1236H1235

H1228 H1229 H1230

H1231

H1233

H1239

H1244 H1243 H1242

H1245

H1006

H1005

H1001

H1000

ST1

H1003

H1004

H1205

H1221

H1036

H1037

H1035

H1033

H1032

H1030

H1029

H1034

H1031

H1120

H1114

H1115

H1122

H1118

H1117

H1109

H1108

H1103

H1102

H1047

H1045

H1219

H1216 H1217

H1251

H1208

H1024

H1107

H1019

H1016

H1013

H1011A

H1026

H1025

H1027

H1119

H1017

H1015

H1012

H1023

H1101

H1200

AE204H

A2

W1

W2

W3

W4

W5

W6

W7

W8

W9

W10

W11

W12

W13

W14

W15

W16

WA

WB

WC

WC

WD

WD

WE

WE

WF

WG

WH

WJ

WK

EZ EA EB EC ED EE EF EG EH EJ EK EL EM EN EP

E1

E2

E3

E4

E5

E6

E7

E8

E9

E10

E11

E12

E13

E14

E15

E16

H1043

H1203

'-8

H1008

H1240

H1307

H1309

H1308

1107A

1107B

1113B

1113A

M8R1

S6NS6N

E17

E18

EQ

A1

AE310H

A6

AE313H

A6

AE310H

A4

AE310H

A3

AE310H

_____ A1

AE311H

A6

AE311H

A4

AE311H

A1

AE312H

A3

AE312H

A1

AE313H

'-0

'-1

0"

8' -9

'-9

9' -1

'-3

'-3

'-1

'-0

'-7

'-0

'-0

'-7

/2

'-5

/2

'-0

17'-8"

9'-6"

32'-11"

32'-1"

8'

-9

39'-8 1/2" 66'-0" 149'-4"

A1

AE301H

A1

AE301H

150'-8 1/2" 34'-3" 24'-0" 59'-8"

C1

AE302H

_____C1

AE302H

A1

AE302H

A1

AE302H

D1

AE302H

D1

AE302H

D3

AE301H

D3

AE301H

C3

AE301H

C3

AE301H

27'-9"

20'-3"

24'-0"

16'-7"

11'-11"

17'-8"

9'-6"

'-5

'-0

'-1

8'

-0

'-3

5'

-6

4' -6

'-3

1' -9

'-4

'-1

0"

'-1

8' -5

'-4

'-4

'-0

'-0

1'-6" 15'-10" 17'-11" 20'-7" 21'-6" 21'-0" 22'-9" 23'-2" 29'-6" 4'-3" 12'-11" 8'-4" 9'-6" 14'-6" 24'-0"

1'-8"

H1311

H1312

H1312

SCALE: 1/16" = 1'-0"

HQ FIRST FLOOR OVERALL PLAN

GRAPHIC SCALE(S)

KEY PLAN

1/16" = 1' - 0" 0 5' 10' 20' 30' 60'

A

B C

D

VIRGINIA BEACH, VIRGINIA 23462

4525 MAIN STREET, SUITE 1400

757·455·5800

1 2 3 4 5 6

A

B

C

D

E

SHEET

B

C

D

E

DESIGN:

DRAWN:

REVIEW:

REVISIONSDESIGNER

A

PROFESSIONAL SEAL

NOT F

OR C

ONSTRUCTIO

N

5032 ROUSE DRIVE, SUITE 200

VIRGINIA BEACH, VA 23462-3764

757.490.9264

CIVIL CONSULTANT

C U s e rs

\B G

U R

C Z

Y N

S K

I\ O n e D ri v e

C la rk N e x s e n \D o c u m e n ts

\1

P o rt s m o u th C o m p le x H

Q A b g u rc z y n s k i_

C la rk N e x s e n c o m

.r v t

/1

/2

:1

:4

P

M

HQ FIRST FLOOR OVERALL PLAN

Designer

Author

Checker

CN 1020535% SUBMITTAL DOCUMENTS

JANUARY 16, 2024

PORTSMOUTH PUBLIC SAFETY COMPLEX

CITY OF PORTSMOUTH

3701 WILLETT DR

PORTSMOUTH, VA 23707

AE001H

DN

UP

AE201H

A1

AE201H

C1

AE201H

B1

AE201H

D1

AE203H

D1

AE105H

AE106H

AE105H

AE106H

A E

7H

A E

6H

A E

7H

A E

6H

AE107H

AE108H

AE107H

AE108H

AE202H

D1

AE202H

C6

AE203H

C1

AE203H

C4

AE203H

A1

AE204H

D2

AE204H

D1

AE204H

B2

AE204H

B1

AE204H

C1

AE202H

A1

AE202H

C1

H2103

H2249

H2105

ELV 2

H2019

H2011

H2017

H2008

H2125

ST1

ELV 4

H2010

H2023

ST2

H2119

H2054

H2022

H2021

H2129

H2218

H2214

H2217

H2311

ELV 3

ST3

H2238

H2314 H2312

H2235

H2236

H2323

H2028

H2000

H2234

H2233

H2315

H2102

H2104

H2209

H2206

H2131

H2208

H2207

H2130

H2203

H2221 H2224H2223

H2200H2201

H2222

H2202

H2215

H2211

H2205

H2020

H2013

H2014

H2012

H2016

H2015

H2018

H2056

H2057

H2065

H2055

H2101H2100

H2247

H2306

H2246

H2303 H2301

H2248

H2310

H2308 H2307

H2305

H2135

H2136

H2213

H2210

H2212 H2216

H2313

H2229

H2006

H2007

H2044

H2004

H2005

H2024

H2026

H2025

H2237

H2317

H2324

H2325

H2320

H2053

H2318

H2319

H2321 H2322

H2316

H2219 H2126

H2111

H2112

H2113

H2116

H2117

H2120

H2121

H2115

H2128

H2124

H2052

H2122

H2123

H2133

H2114B

H2118

H2309

H2302

H2304

H2232

H2228

H2225

H2227

H2241

H2244 H2242

H2245

H2240

H2243

H2220

H2009

H2127

H2051

H2034

H2045

H2043

H2033

H2042

H2027

H2030

H2029

H2031

H2032

H2050

H2049

H2048

H2047

H2046

H2035

H2036

H2037

H2038

H2039

H2041

H2040

AE204H

A2

W1

W2

W2

W3

W3

W4

W5

W6

W7

W8

W9

W10

W11

W12

W13

W14

W15

W16

W16

WA

WB

WC

WC

WD

WD

WE

WE

WF

WF

WG

WG

WH

WH

WJ

WK

EZ EA EB EC ED EE EF EG EH EJ EK EL EM EN EP

E1

E2

E3

E4

E5

E6

E7

E8

E9

E10

E11

E12

E13

E14

E15

E16

H

H2003

H2001

E17

E18

EQ

A1

AE310H

A6

AE313H

A6

AE310H

A4

AE310H

A3

AE310H

A1

AE311H

A6

AE311H

A4

AE311H

A1

AE312H

A3

AE312H

A1

AE313H

'-0

'-0

'-0

'-0

19'-10"

20'-0"

85'-0"

'-0

3/

20'-0"

'-8

17'-8"

9'-6"

32'-11"

32'-1"

8'

-9

/2

39'-8 119/256" 66'-0" 149'-9 13/16"

24'-0" 59'-8"

27'-9"

20'-3"

24'-0"

16'-7"

11'-11"

17'-8"

9'-6"

'-5

'-0

'-1

8'

-0

'-3

5'

-6

4' -6

'-3

1' -9

'-4

'-1

0"

'-1

8' -5

'-4

'-4

'-0

'-0

1'-6" 15'-10" 17'-11" 20'-7" 21'-6" 21'-0" 22'-9" 23'-2" 29'-6" 4'-3" 12'-11" 8'-4" 9'-6" 14'-6" 24'-0"

1'-8"

OPEN TO BELOW

SCALE: 1/16" = 1'-0"

HQ SECOND FLOOR OVERALL PLAN

A

B C

D

VIRGINIA BEACH, VIRGINIA 23462

4525 MAIN STREET, SUITE 1400

757·455·5800

1 2 3 4 5 6

A

B

C

D

E

SHEET

B

C

D

E

DESIGN:

DRAWN:

REVIEW:

REVISIONSDESIGNER

A

PROFESSIONAL SEAL

NOT F

OR C

ONSTRUCTIO

N

5032 ROUSE DRIVE, SUITE 200

VIRGINIA BEACH, VA 23462-3764

757.490.9264

CIVIL CONSULTANT

C U s e rs

\B G

U R

C Z

Y N

S K

I\ O n e D ri v e

C la rk N e x s e n \D o c u m e n ts

\1

P o rt s m o u th C o m p le x H

Q A b g u rc z y n s k i_

C la rk N e x s e n c o m

.r v t

/1

/2

:1

:5

P

M

HQ SECOND FLOOR OVERALL PLAN

Designer

Author

Checker

CN 1020535% SUBMITTAL DOCUMENTS

JANUARY 16, 2024

PORTSMOUTH PUBLIC SAFETY COMPLEX

CITY OF PORTSMOUTH

3701 WILLETT DR

PORTSMOUTH, VA 23707

AE002H

GRAPHIC SCALE(S)

KEY PLAN

1/16" = 1' - 0" 0 5' 10' 20' 30' 60'

W D

'-0

'-0

'-0

20'-0"

20'-0"

5'-0"

5'-0"

'-6

17'-11"

6' -0

6'-11"

8' -4

18'-0"

31'-11" 6'-0" 27'-1"

AE102H AE102H

AE101H

PROPERTY &

EVIDENCE

H1002

VEHICLE

EXAMINATION

H1014

SHIPPING &

RECEIVING

H1009

SALLY PORT

H1021

STAIR

ST2

ELEV.

ELV 1

RESIDENTIAL

SIMULATOR

H1042

MEN'S TOILET

H1046

COMPUTER

CLASSROOM

H1038

FIRE TRAINING

OFFICE

H1028

ELEC.

H1040

TELECOM

H1041

PRIVATE

CORRIDOR

H1022

PRIVATE

CORRIDOR

H1010

FORENSICS LAB

H1018

BREAK

H1039

LRG. CONF.

H1043

OFFICER LOBBY

H1006

VESTIBULE

H1005

VESTIBULE

H1001

PUBLIC LOBBY

H1000

STAIR

ST1

GUN CAGE

H1003

DRUG CAGE

H1004

EMS VIEWING

H1036

EMS TRAINING

H1037

SML. CONF.

H1035

STORAGE

H1033

LT OFFICE

H1032

CLINICAL

H1030

CAPTAIN

H1029

LT

H1034

STORAGE

H1031

WOMEN'S

TOILET

H1045

VESTIBULE

H1024

FILE AND

SUPPLY

STORAGE

H1019

AFIS STORAGE

H1016

QUARTERMASTER

H1011A

STORAGE

H1026

ANIMAL

SERVICES

H1025

VESTIBULE

H1027

FORENSIC TECH

H1017

EQUIPMENT

STORAGE

H1015

VESTIBULE

H1012

CORRIDOR

H1023

PROPERTY &

EVIDENCE

H1002

AFIS STORAGE

H1016

FORENSICS

H1013

AE204H

B1

AE204H

C1

AE202H

C1

AE202H

A1

AE204H

A2

A1

AE301H

_____A1

AE301H

OFFICE

H1017A

AE404H

A5

CORRIDOR

H1017B

CORRIDOR

H1044

14'-6"59'-0"20'-1"

20'-0" 96'-0" 100'-0"

12'-0" 6'-2" 22'-9"

28'-11"

W9

W10

W11

W12

W13

W14

W15

W16

WA WB WC WD WE WF WG WH WJ WK

A

B

1009A

1009B

C

1009B

1009D

1009E

A

A

B

1011C

1011D

E

B

A

ST2

ST2

A

S T

1034 1031

E

T

A

1042E

1042D

B

C

F

B2B1B1B1B1

B

B

B1 B1 B2

B1021C

1021D

1021B 10

A

1102A

9'-5" 27'-3" 11'-0"

'-1

1"

19'-3 1/2"

'-2

'-2

'-0

7' -1

3/

8"

'-8

'-7

5' -5

'-6

5' -2

9' -1

1"

'-2

'-0

/2

5' -8

'-2

'-7

6'

-2

33'-6"26'-5"25'-5"

93'-8 1/4"18'-7"22'-9"26'-7 5/8"31'-11"

M8R2M8R2

S6NS6N

S6N

S6NS6N

S6N

S6N

S6R1S6R1

S6NS6N

S6N

B

S6N

S6N

S6N

S6NS6N

S6NS6N

S6N

S6N S6N

S6NS6N

S6N

S6NS6N

S6NS6N

S6NS6N

S6NS6N

S6N

S6R1

M8R1M8R1

M8R1

M8R1

M8R1

M8R1

M8R1

S6R1N S6R1NS6R1N

M8R1FS3

M8R1FS3M8R1FS3 M8R1FS3

BM8

BM8BM8

BM8

S6R1N

S6R1N

S6R1N

S6R1S6R1

S6N

S6R1

S6NS6N

S6R1N

S6R1

8' -4

S6NS6N

S6NS6N

S6NS6N

S6N M8R1

M8R1

M8R1

M8R1

M8R1

M8R1FS3

M8R1FS3

M8R1M8R1

S6R1NS6R1N M8R1FS3

FS6

FS6

A1

AE310H

A6

AE310H

JAN

H1007

FIRE PUMP

H1008

1'-8" 32'-1" 32'-11" 27'-2" 2'-2" 9'-9" 16'-7" 24'-0" 20'-3" 27'-9"

21'-8" 32'-1"

PROPERTY &

EVIDENCE

H1002

PROPERTY &

EVIDENCE

H1002

QUARTERMASTER

H1011A

JAN

H1020

CORRIDOR

H1017B

VCIN TERMINAL

H1047

CHANGING

ROOM

H1011B

CHANGING

ROOM

H1011C

A

E

VIRGINIA BEACH, VIRGINIA 23462

4525 MAIN STREET, SUITE 1400

757·455·5800

1 2 3 4 5 6

A

B

C

D

E

SHEET

B

C

D

E

DESIGN:

DRAWN:

REVIEW:

REVISIONSDESIGNER

A

PROFESSIONAL SEAL

NOT F

OR C

ONSTRUCTIO

N

5032 ROUSE DRIVE, SUITE 200

VIRGINIA BEACH, VA 23462-3764

757.490.9264

CIVIL CONSULTANT

C U s e rs

\B G

U R

C Z

Y N

S K

I\ O n e D ri v e

C la rk N e x s e n \D o c u m e n ts

\1

P o rt s m o u th C o m p le x H

Q A b g u rc z y n s k i_

C la rk N e x s e n c o m

.r v t

/1

/2

:1

:5

P

M

HQ FIRST FLOOR PLAN - AREA A

Designer

Author

Checker

CN 1020535% SUBMITTAL DOCUMENTS

JANUARY 16, 2024

PORTSMOUTH PUBLIC SAFETY COMPLEX

CITY OF PORTSMOUTH

3701 WILLETT DR

PORTSMOUTH, VA 23707

AE101H

GRAPHIC SCALE(S)

KEY PLAN

# KEY NOTES

GENERAL NOTES

1/8" = 1' - 0" 0 5' 10' 15' 30'

A

B C

D

1 PASS THRU SERVICE WINDOW

2 FULL HEIGHT CHAIN LINK FENCE PARTITION WITH SLIDE

GATE

3 EMERGENCY SHOWER AND EYE WASH

4 10,000 LBS HYDRAULIC VEHICLE LIFT

5 FORENSIC EVIDENCE PASS THRU LOCKERS

6 BALLISTIC LEVEL 4 PASS THRU SERVICE WINDOW

7 12' HIGH STORAGE RACKS

8 ONE WAY VIEWING MIRROR

9 CASEWORK WITH LOWER AND UPPER CABINETS

10 RESIDENTIAL CASEWORK WITH LOWER AND UPPER

CABINETS AND CASE WORK ISLAND WITH NO UPPER

CABINET

11 WORK BENCH

12 ROOF ACCESS LADDER

13 6'x6' DOCK LEVELER

14 PROPERTY LOCKER (LOCKABLE WEAPON LOCKERS)

15 WALL MOUNTED FOLD OUT DESK

1. PLAN DIMENSIONS SHOWN ARE TO FACE OF FRAMING MEMBERS, FACE OF

MASONRY, FACE OF EXISTING WALL, AND TO CENTER LINE OF COLUMNS,

EXCLUSIVE OF INTERIOR WALLS

2. PROVIDE FIRE RETARDANT TREATED WOOD BLOCKING IN METAL STUD

PARTITIONS FOR MOUNTING FIXTURES, MILLWORK, SHELVING, HARDWARE,

DOOR STOPS AND OTHER EQUIPMENT

3. VERIFY AND COORDINATE PENETRATIONS THROUGH FLOOR SLABS, ROOF

DECK AND PARTITIONS WITH PM&E AND FP DRAWINGS

SCALE: 1/8" = 1'-0"

HQ FIRST FLOOR PLAN - AREA A

5'-0"

'-6

17'-11"

6' -0

AE101HAE101H

AE103H

AE103H

STAIR

ST2

ELEV.

ELV 1

FORCE

SIMULATOR

H1106

MEN'S TOILET

H1046

RECORDS

H1100

CORRIDOR

H1104

PRIVATE

CORRIDOR

H1022

BREAK ROOM

H1108

PATROL GEAR

ISSUE

H1102

VESTIBULE

H1024

CORRIDOR

H1107

DEFENSE

TACTICS

TRAINING

CLASSROOM

H1121

VEHICLE

SERVICES

H1110

COMPUTER

CLASSROOM

H1111

POLICE

TRAINING

OFFICE

H1116

ELEV.

ELV 2

ACADEMY

CLASSROOM

H1112

STORAGE

H1120

STORAGE

H1114

ARMOR OFFICE

H1115

CADET BREAK

ROOM

H1122

LT

H1118

SRGT

H1117

STORAGE

H1109

RECORDS

H1103

STORAGE

H1119

POLY

H1101

CORRIDOR

H1104

CORRIDOR

H1104

AE204H

D1

AE204H

B2

AE202HD1

AE203HA1

C3

AE301H

_____C3

AE301H

D3

AE301H

D3

AE301H

1107A

1107B

B

1121A

CORRIDOR

H1113

W1

W2

W3

W4

W5

W6

W7

W8

W9

WA WB

WC WD WE WF WG WH WJ

EZ

EA

EB

EC

E8

STORAGE

H1120A

6"

6"

VESTIBULE

H1105

ST2

ST2

A

B2B1B1B1B1

B

B1 B1 B2

B1021C

1021D

1102A

1120A

B

1121B

A

B

C

B

A

20'-2" 20'-2"

'-9

'-0

'-1

1"

'-0

30'-10" 9'-6" 6'-1" 30'-6"

'-7

6'

-2

56'-5 3/4"

'-3

93'-8 1/4"18'-7"22'-9"26'-7 5/8"31'-11"

S6NS6N

S6NS6N

S6NS6N

S6N

S6R1

8' -4

S6N M8R1

M8R1

M8R1

M8R1

M8R1

M8R1FS3

M8R1FS3

M8R1M8R1

S6R1NS6R1N M8R1FS3

S6R1

S6NS6N

S6NS6N

S6N

S6R1

S6N

S6NS6N

S6N

8'-2 1/2"22'-1"6'-1"

S6NAS6NA

S6NA

S6NS6N

S6NS6N

S6N

S6NS6N

S6N

S6NS6N

S6N

S6NS6N

S6N

M8R1FS3M8R1FS3

M8R1A

M8R1

FS3FS3 FS3FS3

FS3FS3

30'-6"

FS6N

FS6N

FS6

FS6

BS6N

BS6N

E17A4

AE310H

'-0

'-1 0"

8' -9

'-9

9' -1

'-3

'-3

'-1

21'-8" 32'-1"

FS3FS3

20'-3"24'-0"16'-7"11'-11"17'-8"9'-6"

JAN

H1020

CORRIDOR

H1017B

SRGT

H1203

CORRIDOR

H1113

VCIN TERMINAL

H1047

SRGT

H1203

CORRIDOR

H1104

S4NA

CORRIDOR

H1104

PUBLIC LOBBY

H1202

8'-0"

25'-3"

25'-3"

14'-1"

1105A

1105B

1113A

VIRGINIA BEACH, VIRGINIA 23462

4525 MAIN STREET, SUITE 1400

757·455·5800

1 2 3 4 5 6

A

B

C

D

E

SHEET

B

C

D

E

DESIGN:

DRAWN:

REVIEW:

REVISIONSDESIGNER

A

PROFESSIONAL SEAL

NOT F

OR C

ONSTRUCTIO

N

5032 ROUSE DRIVE, SUITE 200

VIRGINIA BEACH, VA 23462-3764

757.490.9264

CIVIL CONSULTANT

C U s e rs

\B G

U R

C Z

Y N

S K

I\ O n e D ri v e

C la rk N e x s e n \D o c u m e n ts

\1

P o rt s m o u th C o m p le x H

Q A b g u rc z y n s k i_

C la rk N e x s e n c o m

.r v t

/1

/2

:1

:0

P

M

HQ FIRST FLOOR PLAN - AREA B

Designer

Author

Checker

CN 1020535% SUBMITTAL DOCUMENTS

JANUARY 16, 2024

PORTSMOUTH PUBLIC SAFETY COMPLEX

CITY OF PORTSMOUTH

3701 WILLETT DR

PORTSMOUTH, VA 23707

AE102H

SCALE: 1/8" = 1'-0"

HQ FIRST FLOOR PLAN - AREA B

A

B C

D

GRAPHIC SCALE(S)

KEY PLAN

# KEY NOTES

GENERAL NOTES

1/8" = 1' - 0" 0 5' 10' 15' 30'

1. PLAN DIMENSIONS SHOWN ARE TO FACE OF FRAMING MEMBERS, FACE OF

MASONRY, FACE OF EXISTING WALL, AND TO CENTER LINE OF COLUMNS,

EXCLUSIVE OF INTERIOR WALLS

2. PROVIDE FIRE RETARDANT TREATED WOOD BLOCKING IN METAL STUD

PARTITIONS FOR MOUNTING FIXTURES, MILLWORK, SHELVING, HARDWARE,

DOOR STOPS AND OTHER EQUIPMENT

3. VERIFY AND COORDINATE PENETRATIONS THROUGH FLOOR SLABS, ROOF

DECK AND PARTITIONS WITH PM&E AND FP DRAWINGS

1 CASEWORK WITH LOWER AND UPPER CABINETS

2 WORK COUNTER

3 8' HIGH STORAGE RACKS

4 FORCE SIMULATOR, OWNER FURNISHED CONTRACTOR

INSTALLED

5 MONUMENTAL STAIR WITH TERRAZZO TREADS AND

RISERS WITH BAR STOCK GUARDRAIL AND STAINLESS

STEEL HANDRAIL

6 TERRAZZO TREADS IN MONUMENTAL STAIR PLINTH

7 WOOD STAIR PLINTH

8 WALK OFF MAT

E

3H

A E

2H

A E

2H

AE104H AE104H

RECORDS

H1100

PUBLIC LOBBY

H1202

PUBLIC LOBBY

H1202

MULTIPURPOSE

ROOM

H1204

PREFUNCTION

SPACE

H1250

STORAGE

H1205

POLY

H1101

MENS

H1218

PROFESSIONAL

STANDARDS

H1209

BREIFING ROOM

H1220

MED. CONF.

H1223

MED. CONF.

H1222

EM. ELEC.

H1246

MAIN ELEC.

H1247

ELEV.

ELV 3

STAIR

ST3

FAMILY WAITING

H1207

VISITOR

WAITING

H1211

MAG

H1241

RECORD

STORAGE

H1214

LT OFFICE

H1215

INTERVIEW

H1212

POLYGRAPH

H1213

INTERVIEW

H1210

HEARING

H1238

PUBLIC TOILET

H1227

STORAGE

H1224

PRIVATE

BATHROOM

H1234

BREAK ROOM

H1226

WAITING AREA

H1232

HEARING

H1237

HEARING

H1236

HEARING

H1235

VISITOR

H1228

VISITOR

H1229

VISITOR

H1230

VISITOR

H1231

VISITOR

H1233

HEARING

H1239

REGIONAL

SUPERVISOR

H1244

CHIEF

MAGISTRATE

H1243

CONFERENCE

H1242

PROBABLE

CAUSE

H1245

STO

H1221

WOMENS

H1219

MENS

H1216

WOMENS

H1217

BREAK

H1251

JAN

H1208

ENTRANCE

VESTIBULE

H1200

MECHANICAL

H1248

AE202H

D1

AE202H

C6

AE204H

A1

AE203H

A1

AE203H

D1

D1

AE302H

D1

AE302H

A1

AE302H

A1

AE302H

AV

H1206

STORAGE

H1201

MAGISTRATE

H1240

COAT

H1225

EZ EA EB EC ED EE EF EG EH EJ EK EL EM EN EP

E8E8

E9

E10E10

E11E11

E12

E13E13

E14E14

E15

E16

A

B

C

B

1204D

A

C

B B

B1

B1

B1

B2B2

B2 B2

B1

B1

B1

B B

J 12

B

A

C

D

1202D 1202E

1232A

B

E

1248A 1248B

ST3S

1300B

1'-0" 74'-10" 13'-4" 29'-2" 51'-11" 8'-6 3/16" 12'-9"

'-6

'-4

'-1

1" 6'

-1

/4

'-1

0" 7'

-2

/8

'-6

/2

S6N S6N

S6NS6N

S6N

S6NS6NS6N

S6N

S6N

S6N

S6N

S6N

S4NS4N

S6N

S6N S6N

S6N

S6N

S6N

S6N

S6N

S6N

S6N S6N

S6NS6N

S6N

S6N

S6N

S6N

S6N

S6N S6N S6N

S6NS6N

S6N

S6N

S6NS6NS6N

S6N

M8R1

M8R1M8R1

M8R1FS3

M8R1FS3

FS6FS6

FS6

FS6N

FS6N

FS6NFS6N

FS6

M8R1M8R1

BS6N

BS6NBS6N

BS4N

BS4N

BS4NBS4N

BS4N

BS4N

BS4N

BS4N

BS4N

BS4N

BS4NBS4NBS4N

BS4NBS4N

BS4N

BS4N

BS4N

BS4N BS4N

BS4N

79'-8"

E17

E18

EQ

A6

AE313H

A3

AE310H

A1

AE312H

A3

AE312H

A1

AE313H

3 1 33 1 3

1'-6" 15'-10" 17'-11" 20'-7" 21'-6" 21'-0" 22'-9" 23'-2" 29'-6" 4'-3" 12'-11" 8'-4" 9'-6" 14'-6" 24'-0"

'-5

'-0

'-1

8'

-0

'-3

5'

-6

4' -6

'-3

1' -9

'-4

CORRIDOR

H1312

CORRIDOR

H1311

CORRIDOR

H1312

SRGT

H1203

SRGT

H1203

CORRIDOR

H1104

PUBLIC LOBBY

H1202

6 6

'-3

'-0

'-3

'-1

FS3

FS3

FS3FS3

8' -0

'-3

'-3

'-1

1105A 1105B

A

A

B

B

1202C

VIRGINIA BEACH, VIRGINIA 23462

4525 MAIN STREET, SUITE 1400

757·455·5800

1 2 3 4 5 6

A

B

C

D

E

SHEET

B

C

D

E

DESIGN:

DRAWN:

REVIEW:

REVISIONSDESIGNER

A

PROFESSIONAL SEAL

NOT F

OR C

ONSTRUCTIO

N

5032 ROUSE DRIVE, SUITE 200

VIRGINIA BEACH, VA 23462-3764

757.490.9264

CIVIL CONSULTANT

C U s e rs

\B G

U R

C Z

Y N

S K

I\ O n e D ri v e

C la rk N e x s e n \D o c u m e n ts

\1

P o rt s m o u th C o m p le x H

Q A b g u rc z y n s k i_

C la rk N e x s e n c o m

.r v t

/1

/2

:1

:1

P

M

HQ FIRST FLOOR PLAN - AREA C

Designer

Author

Checker

CN 1020535% SUBMITTAL DOCUMENTS

JANUARY 16, 2024

PORTSMOUTH PUBLIC SAFETY COMPLEX

CITY OF PORTSMOUTH

3701 WILLETT DR

PORTSMOUTH, VA 23707

AE103H

SCALE: 1/8" = 1'-0"

HQ FIRST FLOOR PLAN - AREA C

A

B C

D

GRAPHIC SCALE(S)

KEY PLAN

# KEY NOTES

GENERAL NOTES

1/8" = 1' - 0" 0 5' 10' 15' 30'

1. PLAN DIMENSIONS SHOWN ARE TO FACE OF FRAMING MEMBERS, FACE OF

MASONRY, FACE OF EXISTING WALL, AND TO CENTER LINE OF COLUMNS,

EXCLUSIVE OF INTERIOR WALLS

2. PROVIDE FIRE RETARDANT TREATED WOOD BLOCKING IN METAL STUD

PARTITIONS FOR MOUNTING FIXTURES, MILLWORK, SHELVING, HARDWARE,

DOOR STOPS AND OTHER EQUIPMENT

3. VERIFY AND COORDINATE PENETRATIONS THROUGH FLOOR SLABS, ROOF

DECK AND PARTITIONS WITH PM&E AND FP DRAWINGS

1 BALLISTIC LEVEL 4 PASS THRU SERVICE WINDOW

2 CASEWORK WITH LOWER AND UPPER CABINETS

3 WORK COUNTER

4 PORTABLE STORAGE, OWNER FURNISHED CONTRACTOR

INSTALLED

5 ARCHITECTURAL CONCRETE STEPS

6 WALK OFF MAT

7 SUPER GRAPHIC VINYL WALL COVERING

8 DISPLAY CASE

'-0

'-6

/4

'-0

/4

'-1

/8

0'

-8

14'-0"

AE103HAE103H

STAIR

ST3

MENS LOCKER

ROOM

H1302

WOMENS

LOCKER ROOM

H1301

COMMERCIAL

KITCHEN &

CAFETERIA

H1300

OUTDOOR

COVERED

SEATING

H1310

BREAK

H1251

TELECOM

H1304

ELECTRICAL

H1303

GYM

H1305

BASKETBALL

COURT

H1306

AE203H

D6

AE203H

C1

AE203H

C4

AE203H

A5

AE203H

D1

AE203H

C1

AE403H

A5

1114C

1305E

1305D

B B

B1

B1

B2

B3

B3

B3

B4

B1

B1

B1

B1

B2

B3

B3

B3

B4

1305B

1305C

1305F

1306B

1306C

A

1300C

T E

EF EG

EH EJ EK EL EM EN EP

E1

E2

E3

E4

E5

E6

E7

E8E8

ELECTRICAL

H1307

TELECOM

H1309

TELECOM

H1308

1305A

1307A

B

ST3S

1300B

56'-6 3/8"

6' -1

/4

'-8

/4

'-4

56'-4"

S6N S6N S6N

S6NS6N

S6NS6NS6N

S6N

S6N

S6NS6N

S6N

M8R1

M8R1M8R1

M8R1FS3

M8R1FS3

FS6

M12R2

M12R2

M8R2

M8R2

FS6

S6N

S6N

FS6FS6

EQ

A1

AE311H

A6

AE311H

A4

AE311H

TYP

29'-6" 4'-3" 12'-11" 8'-4" 9'-6" 14'-6" 24'-0"

'-1

0"

'-1

8' -5

'-4

'-4

'-0

'-0

CORRIDOR

H1312

FS4

S6N

CORRIDOR

H1312

VIRGINIA BEACH, VIRGINIA 23462

4525 MAIN STREET, SUITE 1400

757·455·5800

1 2 3 4 5 6

A

B

C

D

E

SHEET

B

C

D

E

DESIGN:

DRAWN:

REVIEW:

REVISIONSDESIGNER

A

PROFESSIONAL SEAL

NOT F

OR C

ONSTRUCTIO

N

5032 ROUSE DRIVE, SUITE 200

VIRGINIA BEACH, VA 23462-3764

757.490.9264

CIVIL CONSULTANT

C U s e rs

\B G

U R

C Z

Y N

S K

I\ O n e D ri v e

C la rk N e x s e n \D o c u m e n ts

\1

P o rt s m o u th C o m p le x H

Q A b g u rc z y n s k i_

C la rk N e x s e n c o m

.r v t

/1

/2

:1

:1

P

M

HQ FIRST FLOOR PLAN - AREA D

Designer

Author

Checker

CN 1020535% SUBMITTAL DOCUMENTS

JANUARY 16, 2024

PORTSMOUTH PUBLIC SAFETY COMPLEX

CITY OF PORTSMOUTH

3701 WILLETT DR

PORTSMOUTH, VA 23707

AE104H

SCALE: 1/8" = 1'-0"

HQ FIRST FLOOR PLAN - AREA D

A

B C

D

GRAPHIC SCALE(S)

KEY PLAN

# KEY NOTES

GENERAL NOTES

1/8" = 1' - 0" 0 5' 10' 15' 30'

1. PLAN DIMENSIONS SHOWN ARE TO FACE OF FRAMING MEMBERS, FACE OF

MASONRY, FACE OF EXISTING WALL, AND TO CENTER LINE OF COLUMNS,

EXCLUSIVE OF INTERIOR WALLS

2. PROVIDE FIRE RETARDANT TREATED WOOD BLOCKING IN METAL STUD

PARTITIONS FOR MOUNTING FIXTURES, MILLWORK, SHELVING, HARDWARE,

DOOR STOPS AND OTHER EQUIPMENT

3. VERIFY AND COORDINATE PENETRATIONS THROUGH FLOOR SLABS, ROOF

DECK AND PARTITIONS WITH PM&E AND FP DRAWINGS

1 CASEWORK WITH LOWER AND UPPER CABINETS

2 TWO TIER LOCKERS

3 LOCKER ROOM BENCH

4 ADA LOCKER ROOM BENCH

5 EXERCISE EQUIPMENT, OWNER FURNISHED OWNER

INSTALLED

ROOF

BELOW

ROOF

BELOW

'-4

AE105H

SPECIAL OPS

H2011

GANG

SUPPRESSION

H2017

BREAK ROOM

H2003

MD. CONF.

H2008

STAIR

ST1

ELEV.

ELV 4

CRIMINAL

INVESTIGATIONS

H2010

STAIR

ST2

MEN'S TOILET

H2054

TELECOM

H2022

ELEC.

H2021

PRIVATE

INTERVIEW

CORE

H2028

MD. CONF.

H2000

STORAGE

H2020

STORAGE

H2013

LT

H2014

STORAGE

H2012

GSU STORAGE

H2016INTERVIEW

H2015

LOBBY

H2018

PIO

H2056

PIO

H2057

ASSISTANT

CHIEF

H2065

ASSISTANT

CHIEF

H2055

STORAGE

H2006

STORAGE

H2007

AV MONITORING

H2044

CAPTAIN

H2004

LT

H2005

STORAGE

H2024

LT

H2026

SURVEILLANCE

EQUP.

H2025

WOMEN'S

TOILET

H2053

SECURITY

H2052

PRINT COPY

H2009

INTERVIEW

H2051

INTERVIEW

H2034

INTERVIEW

H2045

INTERVIEW

H2043

AV MONITORING

H2033

AV MONITORING

H2042

VESTIBULE

H2027

HOLDING

H2030

HOLDING

H2029

HOLDING

H2031

HOLDING

H2032

HOLDING

H2050

HOLDING

H2049

HOLDING

H2048

HOLDING

H2047

HOLDING

H2046

HOLDING

H2035

HOLDING

H2036

HOLDING

H2037

HOLDING

H2038

HOLDING

H2039

UNISEX

H2041

UNISEX

H2040

DISTRICT LTS

H2019

NARCOTICS

H2023

AE202H

A1

AE202H

C1

AE102H

W9

W10

W11

W12

W13

W14

W15

WA WC WD WE WG WH WJ WK

LRG. CONF.

H2001

S

A

B

A

T

E

20162018

B

'-5

'-1 0"

'-1

1"

40'-11 3/16"

'-1

'-8

'-1

0"

'-1 0"

20'-7"

'-0

M8R1FS3

M8R1FS3

M8R1FS3

M8R1FS3

M8R1FS3

M8R1 20 03 S6N S6N

S6N

S6N

S6NS6N

S6NS6N

S6N

S6N

S6NS6N

S6NS6N

S6N

S6N

S6NS6N

M6FS3

M6FS3

M6M6M6M6

M6FS3M6FS3

M6

M6FS3M6FS3

M6M6M6M6M6

M6

M6M6

M6M6 M6M6

M6

M6FS3

M6

S6NS6N

S6N

M6

M6M6M6 M6

M6M6

M6

M6M6

M6M6

M6

M8R1M8R1

M8R1M8R1

M8R1M8R1

M8R1

S6NS6N

S6N

S6N

S6N

S6N

S6NS6N

S6NS6N

M8 M8R1FS3

A

9'-8" 6'-0" 16'-5" 14'-5" 10'-6" 7'-8"

A1

AE310H

A6

AE310H

'-0

'-7

'-7

/2

'-5

/2

27'-9"20'-3"24'-0"28'-6"17'-8"9'-6"65'-0"

FS3FS3 FS3FS3

2010B

CORRIDOR

H2114A

S

S

M8R1

VIRGINIA BEACH, VIRGINIA 23462

4525 MAIN STREET, SUITE 1400

757·455·5800

1 2 3 4 5 6

A

B

C

D

E

SHEET

B

C

D

E

DESIGN:

DRAWN:

REVIEW:

REVISIONSDESIGNER

A

PROFESSIONAL SEAL

NOT F

OR C

ONSTRUCTIO

N

5032 ROUSE DRIVE, SUITE 200

VIRGINIA BEACH, VA 23462-3764

757.490.9264

CIVIL CONSULTANT

C U s e rs

\B G

U R

C Z

Y N

S K

I\ O n e D ri v e

C la rk N e x s e n \D o c u m e n ts

\1

P o rt s m o u th C o m p le x H

Q A b g u rc z y n s k i_

C la rk N e x s e n c o m

.r v t

/1

/2

:1

:2

P

M

HQ SECOND FLOOR PLAN - AREA A

Designer

Author

Checker

CN 1020535% SUBMITTAL DOCUMENTS

JANUARY 16, 2024

PORTSMOUTH PUBLIC SAFETY COMPLEX

CITY OF PORTSMOUTH

3701 WILLETT DR

PORTSMOUTH, VA 23707

AE105H

SCALE: 1/8" = 1'-0"

HQ SECOND FLOOR PLAN - AREA A

A

B C

D

GRAPHIC SCALE(S)

KEY PLAN

# KEY NOTES

GENERAL NOTES

1/8" = 1' - 0" 0 5' 10' 15' 30'

1. PLAN DIMENSIONS SHOWN ARE TO FACE OF FRAMING MEMBERS, FACE OF

MASONRY, FACE OF EXISTING WALL, AND TO CENTER LINE OF COLUMNS,

EXCLUSIVE OF INTERIOR WALLS

2. PROVIDE FIRE RETARDANT TREATED WOOD BLOCKING IN METAL STUD

PARTITIONS FOR MOUNTING FIXTURES, MILLWORK, SHELVING, HARDWARE,

DOOR STOPS AND OTHER EQUIPMENT

3. VERIFY AND COORDINATE PENETRATIONS THROUGH FLOOR SLABS, ROOF

DECK AND PARTITIONS WITH PM&E AND FP DRAWINGS

1 CASEWORK WITH LOWER AND UPPER CABINETS

2 WORK COUNTER

3 PROPERTY LOCKER (LOCKABLE WEAPON LOCKERS)

4 ROOF ACCESS LADDER

5 30" X 66" ROOF HATCH

OPEN TO BELOW

OPEN TO

BELOW

ROOF

BELOW

'-4

AE105H AE105H

AE107H

AE107H

CHIEF OF

POLICE

H2103

STAIR

ST2

MEN'S TOILET

H2054

CRIME

ANALYSIS

H2108

PRIVATE

INTERVIEW

CORE

H2028

SOFT

INTERVIEW

H2106

EXECUTIVE

CONF.

H2104

PIO

H2056

PIO

H2057

ASSISTANT

CHIEF

H2065

COPY/PRINT

H2100

AV MONITORING

H2044

WOMEN'S

TOILET

H2053

BREATHALYZER

H2111

FUGITIVE

APPREHENSION

H2112

SECURITY

H2052

INTERVIEW

H2045

INTERVIEW

H2043

AV MONITORING

H2042

HOLDING

H2050

HOLDING

H2049

HOLDING

H2048

HOLDING

H2047

HOLDING

H2046

UNISEX

H2041

UNISEX

H2040

SM. CONF.

H2105

ELEV.

ELV 2

STREET CRIMES

H2125

ROLL CALL

H2119

WELLNESS

ROOM

H2129

POLICE CHIEF

H2102

SUPERVISOR

H2206

POLYGRAPH

H2131

MEDICAL

DIRECTOR

H2208

CLINCAL CARE

H2207

EM…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .