Public Safety Complex - Preliminary Drawings_Part1.pdf

PDF 26 MB Posted

Attached to
REQUEST FOR PROPOSAL (RFP) # 49-26-SKL PPEA Project to Construct a Public Safety Facility
Solicitation number
RFP-121372
Issued by
Portsmouth City, Virginia

About this file

This file contains preliminary architectural and structural drawings for the Portsmouth Public Safety Complex, a new 35% submittal document dated January 16, 2024, prepared by Clark Nexsen for the City of Portsmouth, Virginia, located at 3701 Willett Drive. The project encompasses three distinct buildings: a headquarters (HQ) facility with 147,533 gross square feet across two stories, a warehouse building with 27,044 square feet, and a training range facility with 13,747 square feet. The HQ building is designed as Type IIB construction serving as a public safety complex containing office space for fire and police departments, emergency operations center, and dispatch facilities. The warehouse provides storage for fire and police departments, while the training range serves as a shooting facility. The complex is designed to accommodate maximum occupancy loads of 1,203 people in the HQ building, 74 people in the warehouse, and 82 people in the training range. Design compliance follows the 2018 Virginia Construction Code, 2017 NFPA 70 National Electrical Code, 2016 NFPA 13 sprinkler standards, and 2010 ADA accessibility requirements.

The structural design utilizes steel ordinary concentrically braced frames for lateral load resistance, composite concrete slabs at elevated floors, and open-web steel joists. Foundations are designed for a net allowable bearing capacity of 4,000 PSF on undisturbed soil or engineered fill with rigid inclusions per geotechnical recommendations. The HQ building features 1-hour fire-rated exits and vertical enclosures with no sprinkler system but with fire detection and alarm systems throughout. The warehouse operates as non-sprinklered Type IIB construction with 0-hour fire ratings for most building elements. Design wind loads are based on 130 mph basic design wind speed for Risk Category IV structures, with seismic design for Seismic Design Category A. The preliminary drawings include comprehensive sheet indexes, life safety plans, structural notes, foundation and framing plans, architectural floor plans, reflected ceiling plans, exterior elevations, building sections, wall sections, mechanical, electrical, plumbing, fire protection, and telecom systems documentation to support the 35% design submittal phase.

View the file

Other files

Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

VIRGINIA BEACH, VIRGINIA 23462

4525 MAIN STREET, SUITE 1400

757·455·5800

1 2 3 4 5 6

A

B

C

D

E

SHEET

B

C

D

E

DESIGN:

DRAWN:

REVIEW:

REVISIONSDESIGNER

A

PROFESSIONAL SEAL

NOT F

OR C

ONSTRUCTIO

N

5032 ROUSE DRIVE, SUITE 200

VIRGINIA BEACH, VA 23462-3764

757.490.9264

CIVIL CONSULTANT

C U s e rs

\B G

U R

C Z

Y N

S K

I\ O n e D ri v e

C la rk N e x s e n \D o c u m e n ts

\1

P o rt s m o u th C o m p le x H

Q A b g u rc z y n s k i_

C la rk N e x s e n c o m

.r v t

/1

/2

:2

:5

P

M

COVER SHEET

Designer

Author

Checker

CN 1020535% SUBMITTAL DOCUMENTS

JANUARY 16, 2024

PORTSMOUTH PUBLIC SAFETY COMPLEX

CITY OF PORTSMOUTH

3701 WILLETT DR

PORTSMOUTH, VA 23707

G-001

N

PORTSMOUTH PUBLIC SAFETY COMPLEX

CITY OF PORTSMOUTH

35% SUBMITTAL DOCUMENTS

JANUARY 16, 2024

3701 WILLETT DR

PORTSMOUTH, VA 23707

SITE MAP

PROJECT SITE

VICINITY MAP

CONSTRUCTION MANAGER

x

OWNER

CITY OF PORTSMOUTH

ENGINEERING AND TECHNICAL SERVICES

801 CRAWFORD STREET, 4TH FLOOR

PORTSMOUTH, VIRGINIA 23704

PROJECT TEAM

MECHANICAL, PLUMBING, ELECTRICAL

AND FIRE PROTECTION ENGINEER

CLARK NEXSEN

4525 MAIN STREET, SUITE 1400

VIRGINIA BEACH, VA 23462

T: 757.455.5800 F: 757.455.5638

ARCHITECT

CLARK NEXSEN

4525 MAIN STREET, SUITE 1400

VIRGINIA BEACH, VA 23462

T: 757.455.5800 F: 757.455.5638

LANDSCAPE ARCHITECT

CLARK NEXSEN

4525 MAIN STREET, SUITE 1400

VIRGINIA BEACH, VA 23462

T: 757.455.5800 F: 757.455.5638

STRUCTURAL ENGINEER

CLARK NEXSEN

4525 MAIN STREET, SUITE 1400

VIRGINIA BEACH, VA 23462

T: 757.455.5800 F: 757.455.5638

PROJECT SITE

CIVIL ENGINEER

MSA

5032 ROUSE DRIVE, SUITE 200

VIRGINIA BEACH, VA 23462-3764

T: 757.490.9264

- SITE PACKAGE

1 2 3 4 5 6

C

D

E

C

D

E

PORTSMOUTH PUBLIC SAFETY COMPLEX

CITY OF PORTSMOUTH

PRELIMINARY DRAWINGS

JANUARY 16, 2024

3701 WILLETT DR

PORTSMOUTH, VA 23707

DETAIL / PLAN NUMBER

SHEET WHERE SHOWN

COLUMN GRID LINE

ELEVATION DATUM

+12'-0"

FIRST FLOOR

ROOM DESIGNATION

PLAN TITLE AND

NORTH ARROW

ELEVATION NUMBER

SHEET WHERE SHOWN

SECTION NUMBER

SHEET WHERE SHOWN

1E1

EXISTING COLUMN GRID LINE

A1

DETAIL NUMBER

SHEET NUMBER REFERENCE NOTED IN GENERAL NOTES ON SHEET

BUILDING

SHEET WHERE SHOWN

SECTION NUMBER

NAME

SCALE:

A1

NAME

SCALE:

TRUE NORTH INDICATOR

PLAN NORTH INDICATOR

ROOM NAME

BUILDING

3D

A1 / AE101A1 / AE101

A1

AE301

A1

AE201

A1

AE410

A1

A1

AE402

A3

A2A4

A1

AE301

A1

AE311

ADDITIONAL ID INFO

IF USED

VIEW REFERENCE

ELEVATION NUMBER

SHEET WHERE SHOWN

DETAIL /

ENLARGED PLAN

INTERIOR

ELEVATION

EXTERIOR

ELEVATION

BUILDING SECTION

DETAIL / WALL

SECTION

DETAIL SECTION

PHOTOGRAPH / 3D

VIEW REFERENCE

DETAIL, SECTION,

ELEVATION TITLE

REVISION TAG

A1 / AE101

ADJACENT AREA

REFERENCE 1

MATCHLINE

DEMOLITION KEYNOTENEW WORK KEYNOTE

VIRGINIA BEACH, VIRGINIA 23462

4525 MAIN STREET, SUITE 1400

757·455·5800

1 2 3 4 5 6

A

B

C

D

E

SHEET

B

C

D

E

DESIGN:

DRAWN:

REVIEW:

REVISIONSDESIGNER

A

PROFESSIONAL SEAL

NOT F

OR C

ONSTRUCTIO

N

5032 ROUSE DRIVE, SUITE 200

VIRGINIA BEACH, VA 23462-3764

757.490.9264

CIVIL CONSULTANT

C U s e rs

\B G

U R

C Z

Y N

S K

I\ O n e D ri v e

C la rk N e x s e n \D o c u m e n ts

\1

P o rt s m o u th C o m p le x G e n e ra l_ A b g u rc z y n s k i_

C la rk N e x s e n c o m

.r v t

/1

/2

:2

:0

P

M

SHEET INDEX AND GENERAL PROJECT

SYMBOLOGY

Designer

Author

Checker

CN 1020535% SUBMITTAL DOCUMENTS

JANUARY 16, 2024

PORTSMOUTH PUBLIC SAFETY COMPLEX

CITY OF PORTSMOUTH

3701 WILLETT DR

PORTSMOUTH, VA 23707

GI001

SHEET INDEX - VOLUME IGENERAL PROJECT SYMBOLOGY

SHEET

NUMBER SHEET NAME

SHEET

NUMBER SHEET NAME

GENERAL

G-001 COVER SHEET

GI001 SHEET INDEX AND GENERAL PROJECT SYMBOLOGY

GI002H BUILDING CODE SUMMARY

GI101H HQ FIRST FLOOR LIFE SAFETY PLAN

GI102H HQ SECOND FLOOR LIFE SAFETY PLAN

GI110H ROOM NUMBER DIAGRAMS

GI101W WAREHOUSE LIFE SAFETY PLAN

GI101T RANGE LIFE SAFETY PLAN

STRUCTURAL

S-001 STRUCTURAL NOTES

S-002 STRUCTURAL NOTES

S-001H HQ STRUCTURAL NOTES

SB101H HQ FOUNDATION PLAN - OVERALL

SB102H HQ FOUNDATION PLAN - AREA A

SB103H HQ FOUNDATION PLAN - AREA B

SB104H HQ FOUNDATION PLAN - AREA C

SB105H HQ FOUNDATION PLAN - AREA D

SB301H HQ FOUNDATION SECTIONS

SB501H HQ TYPICAL FOUNDATION DETAILS

SB502H HQ TYPICAL SLAB-ON-GRADE DETAILS

SF101H HQ SECOND FLOOR FRAMING PLAN - OVERALL

SF102H HQ SECOND FLOOR FRAMING PLAN - AREA A

SF103H HQ SECOND FLOOR FRAMING PLAN - AREA B

SF104H HQ SECOND FLOOR FRAMING PLAN - AREA C

SF105H HQ SECOND FLOOR FRAMING PLAN - AREA D

SF111H HQ ROOF FRAMING PLAN - OVERALL

SF112H HQ ROOF FRAMING PLAN - AREA A

SF113H HQ ROOF FRAMING PLAN - AREA B

SF114H HQ ROOF FRAMING PLAN - AREA C

SF115H HQ ROOF FRAMING PLAN - AREA D

SF116H HQ ROOF FRAMING PLAN - AREA C

SF117H HQ ROOF SCREENWALL FRAMING PLAN - AREA C

SF201H HQ BRACED FRAME ELEVATIONS

SF202H HQ BRACED FRAME ELEVATIONS

SF301H HQ FRAMING SECTIONS

SF501H HQ TYPICAL FRAMING DETAILS

SF502H HQ TYPICAL FRAMING DETAILS

S-001W WAREHOUSE STRUCTURAL NOTES

SB101W WAREHOUSE FOUNDATION PLAN

SB301W WAREHOUSE SECTIONS

SB501W WAREHOUSE TYPICAL DETAILS

S-001T TRAINING STRUCTURAL NOTES

SB101T TRAINING FOUNDATION PLAN

SB501T TRAINING TYPICAL FOUNDATION DETAILS

SF101T TRAINING ROOF FRAMING PLAN

SF501T TRAINING TYPICAL FRAMING DETAILS

ARCHITECTURAL

A-001 ARCHITECTURAL LEGEND, NOTES AND ABBREVIATIONS

AE001H HQ FIRST FLOOR OVERALL PLAN

AE002H HQ SECOND FLOOR OVERALL PLAN

AE101H HQ FIRST FLOOR PLAN - AREA A

AE102H HQ FIRST FLOOR PLAN - AREA B

AE103H HQ FIRST FLOOR PLAN - AREA C

AE104H HQ FIRST FLOOR PLAN - AREA D

AE105H HQ SECOND FLOOR PLAN - AREA A

AE106H HQ SECOND FLOOR PLAN - AREA B

AE107H HQ SECOND FLOOR PLAN - AREA C

AE108H HQ SECOND FLOOR PLAN - AREA D

AE110H HQ FIRST FLOOR REFLECTED CEILING PLAN - AREA A

AE111H HQ FIRST FLOOR REFLECTED CEILING PLAN - AREA B

AE112H HQ FIRST FLOOR REFLECTED CEILING PLAN - AREA C

AE113H HQ FIRST FLOOR REFLECTED CEILING PLAN - AREA D

AE114H HQ SECOND FLOOR REFLECTED CEILING PLAN - AREA A

AE115H HQ SECOND FLOOR REFLECTED CEILING PLAN - AREA B

AE116H HQ SECOND FLOOR REFLECTED CEILING PLAN - AREA C

AE117H HQ SECOND FLOOR REFLECTED CEILING PLAN - AREA D

AE120H HQ OVERALL ROOF PLAN

AE201H HQ OVERALL EXTERIOR ELEVATIONS

AE202H HQ EXTERIOR ELEVATIONS

AE203H HQ EXTERIOR ELEVATIONS

AE204H HQ EXTERIOR ELEVATIONS

AE301H HQ BUILDING SECTIONS

AE302H HQ BUILDING SECTIONS

AE310H HQ WALL SECTIONS

AE311H HQ WALL SECTIONS

AE312H HQ WALL SECTIONS

AE313H HQ WALL SECTIONS

AE403H HQ ENLARGED KITCHEN PLAN

AE404H HQ ENLARGED PLANS

AE501H PARTITION TYPES AND DETAILS

AE601H HQ DOOR SCHEDULE AND DOOR / FRAME TYPES

AE602H HQ DOOR SCHEDULE

AE101W WAREHOUSE FIRST FLOOR PLAN

AE110W WAREHOUSE REFLECTED CEILING PLAN

AE120W WAREHOUSE ROOF PLAN

AE201W WAREHOUSE EXTERIOR ELEVATIONS

AE301W WAREHOUSE BUILDING SECTIONS

AE310W WAREHOUSE WALL SECTIONS

AE601W WAREHOUSE DOOR SCHEDULE AND DOOR / FRAME TYPES

AE101T TRAINING FIRST FLOOR PLAN

AE110T TRAINING FIRST FLOOR REFLECTED CEILING PLAN

AE120T TRAINING ROOF PLAN

AE201T TRAINING EXTERIOR ELEVATIONS

AE301T TRAINING BUILDING SECTIONS

AE310T TRAINING WALL SECTIONS

AE601T TRAINING DOOR SCHEDULE

SHEET

NUMBER SHEET NAME

INTERIORS

IN601H HQ - FINISH SCHEDULE & NOTES

IN602H FINISH LEGEND & GENERAL FINISH NOTES

IN601W WAREHOUSE - FINISH SCHEDULE & NOTES

IN601T TRAINING - FINISH SCHEDULE & NOTES

FIRE PROTECTION

F-001 FIRE PROTECTION LEGEND

F-002 SEQUENCE OF OPERATIONS

FP101H HQ FIRST FLOOR FIRE PROTECTION PLAN - AREA A

FP102H HQ FIRST FLOOR FIRE PROTECTION PLAN - AREA B

FP103H HQ FIRST FLOOR FIRE PROTECTION PLAN - AREA C

FP104H HQ FIRST FLOOR FIRE PROTECTION PLAN - AREA D

FP105H HQ SECOND FLOOR FIRE PROTECTION PLAN - AREA A

FP106H HQ SECOND FLOOR FIRE PROTECTION PLAN - AREA B

FP107H HQ SECOND FLOOR FIRE PROTECTION PLAN - AREA C

FP108H HQ SECOND FLOOR FIRE PROTECTION PLAN - AREA D

FP401H HQ ENLARGED FIRE PUMP ROOM

PLUMBING

P-001 PLUMBING LEGEND

PF101H HQ FOUNDATION PLAN - AREA A

PF102H HQ FOUNDATION PLAN - AREA B

PF103H HQ FOUNDATION PLAN - AREA C

PF104H HQ FOUNDATION PLAN - AREA D

PL101H HQ FIRST FLOOR PLAN - AREA A

PL102H HQ FIRST FLOOR PLAN - AREA B

PL103H HQ FIRST FLOOR PLAN - AREA C

PL104H HQ FIRST FLOOR PLAN - AREA D

PL105H HQ SECOND FLOOR PLAN - AREA A

PL106H HQ SECOND FLOOR PLAN - AREA B

PL107H HQ SECOND FLOOR PLAN - AREA C

PL108H HQ SECOND FLOOR PLAN - AREA D

P-601H SCHEDULES

PF101W WAREHOUSE FOUNDATION PLAN

PL101W WAREHOUSE FIRST FLOOR PLAN

P-601W SCHEDULES

PF101T TRAINING FOUNDATION PLAN

PL101T TRAINING FIRST FLOOR PLAN

P-601T SCHEDULES

MECHANICAL

M-001 MECHANICAL LEGEND

MZ101H HQ FIRST FLOOR OVERALL HVAC SYSTEMS PLAN

MZ102H HQ SECOND FLOOR OVERALL HVAC SYSTEMS PLAN

MZ103H HQ FIRST FLOOR OVERALL HVAC ZONING PLAN

MZ104H HQ SECOND FLOOR OVERALL HVAC ZONING PLAN

MH101H HQ FIRST FLOOR DUCTWORK PLAN - AREA A

MH102H HQ FIRST FLOOR DUCTWORK PLAN - AREA B

MH103H HQ FIRST FLOOR DUCTWORK PLAN - AREA C

MH104H HQ FIRST FLOOR DUCTWORK PLAN - AREA D

MH105H HQ SECOND FLOOR DUCTWORK PLAN - AREA A

MH106H HQ SECOND FLOOR DUCTWORK PLAN - AREA B

MH107H HQ SECOND FLOOR DUCTWORK PLAN - AREA C

MH108H HQ SECOND FLOOR DUCTWORK PLAN - AREA D

MP101H HQ FIRST FLOOR PIPING PLAN - AREA A

MP102H HQ FIRST FLOOR PIPING PLAN - AREA B

MP103H HQ FIRST FLOOR PIPING PLAN - AREA C

MP104H HQ FIRST FLOOR PIPING PLAN - AREA D

MP105H HQ SECOND FLOOR PIPING PLAN - AREA A

MP106H HQ SECOND FLOOR PIPING PLAN - AREA B

MP107H HQ SECOND FLOOR PIPING PLAN - AREA C

MP108H HQ SECOND FLOOR PIPING PLAN - AREA D

M-111H HQ OVERALL ROOF PLAN

M-401H HQ ENLARGED PLANS

M-601H HQ SCHEDULES

M-602H HQ SCHEDULES

M-603H HQ SCHEDULES

M-604H HQ SCHEDULES

M-701H HQ DIAGRAMS

MZ101W WAREHOUSE FIRST FLOOR HVAC ZONING PLAN

MH101W WAREHOUSE FIRST FLOOR PLAN - AREA A

MH102W WAREHOUSE FIRST FLOOR PLAN - AREA B

M-601W WAREHOUSE SCHEDULES

M-602W WAREHOUSE SCHEDULES

MH101T TRAINING FIRST FLOOR DUCTWORK PLAN

M-601T TRAINING SCHEDULES

ELECTRICAL

E-001 ELECTRICAL LEGEND, NOTES AND ABBREVIATIONS

EL101H HQ FIRST FLOOR LIGHTING PLAN - AREA A

EL102H HQ FIRST FLOOR LIGHTING PLAN - AREA B

EL103H HQ FIRST FLOOR LIGHTING PLAN - AREA C

EL104H HQ FIRST FLOOR LIGHTING PLAN - AREA D

EL105H HQ SECOND FLOOR LIGHTING PLAN - AREA A

EL106H HQ SECOND FLOOR LIGHTING PLAN - AREA B

EL107H HQ SECOND FLOOR LIGHTING PLAN - AREA C

EL108H HQ SECOND FLOOR LIGHTING PLAN - AREA D

EL601H HQ LIGHTING FIXTURE SCHEDULE

EL602H HQ LIGHTING CONTROL SCHEDULES

EL603H HQ LIGHTING CONTROL SCHEDULES

EL604H HQ LIGHTING CONTROL SCHEDULES

EL605H HQ LIGHTING CONTROL SCHEDULES

EP101H HQ FIRST FLOOR POWER PLAN - AREA A

EP102H HQ FIRST FLOOR POWER PLAN - AREA B

EP103H HQ FIRST FLOOR POWER PLAN - AREA C

EP104H HQ FIRST FLOOR POWER PLAN - AREA D

EP105H HQ SECOND FLOOR POWER PLAN - AREA A

EP106H HQ SECOND FLOOR POWER PLAN - AREA B

EP107H HQ SECOND FLOOR POWER PLAN - AREA C

SHEET

NUMBER SHEET NAME

EP108H HQ SECOND FLOOR POWER PLAN - AREA D

EP201H HQ FIRST FLOOR EQUIPMENT CONNECTIONS PLAN - AREA A

EP202H HQ FIRST FLOOR EQUIPMENT CONNECTIONS PLAN - AREA B

EP203H HQ FIRST FLOOR EQUIPMENT CONNECTIONS PLAN - AREA C

EP204H HQ FIRST FLOOR EQUIPMENT CONNECTIONS PLAN - AREA D

EP205H HQ SECOND FLOOR EQUIPMENT CONNECTIONS PLAN - AREA A

EP206H HQ SECOND FLOOR EQUIPMENT CONNECTIONS PLAN - AREA B

EP207H HQ SECOND FLOOR EQUIPMENT CONNECTIONS PLAN - AREA C

EP208H HQ SECOND FLOOR EQUIPMENT CONNECTIONS PLAN - AREA D

EP221H HQ ELECTRICAL ROOF PLAN - AREA A

EP222H HQ ELECTRICAL ROOF PLAN - AREA B

EP223H HQ ELECTRICAL ROOF PLAN - AREA C

EP224H HQ ELECTRICAL ROOF PLAN - AREA D

EP401H HQ ENLARGED POWER PLANS

EP402H HQ ENLARGED POWER PLANS

EP403H HQ ENLARGED POWER PLANS

EP601H HQ EQUIPMENT CONNECTION SCHEDULE

EP602H HQ EQUIPMENT CONNECTION SCHEDULE

EP603H HQ EQUIPMENT CONNECTION SCHEDULE

EP701H HQ PARTIAL POWER RISER DIAGRAM

EP702H HQ PARTIAL POWER RISER DIAGRAM

EP703H HQ PARTIAL POWER RISER DIAGRAM

EP704H HQ PARTIAL POWER RISER DIAGRAM

ET101H HQ FIRST FLOOR TELECOM PLAN - AREA A

ET102H HQ FIRST FLOOR TELECOM PLAN - AREA B

ET103H HQ FIRST FLOOR TELECOM PLAN - AREA C

ET104H HQ FIRST FLOOR TELECOM PLAN - AREA D

ET105H HQ SECOND FLOOR TELECOM PLAN - AREA A

ET106H HQ SECOND FLOOR TELECOM PLAN - AREA B

ET107H HQ SECOND FLOOR TELECOM PLAN - AREA C

ET108H HQ SECOND FLOOR TELECOM PLAN - AREA D

ET401H HQ ENLARGED TELECOM PLANS

ET402H HQ ENLARGED TELECOM PLANS

ET501H HQ TELECOM DETAILS

ET701H HQ TELECOM RISER DIAGRAMS

EY101H HQ FIRST FLOOR SECURITY PLAN - AREA A

EY102H HQ FIRST FLOOR SECURITY PLAN - AREA B

EY103H HQ FIRST FLOOR SECURITY PLAN - AREA C

EY104H HQ FIRST FLOOR SECURITY PLAN - AREA D

EY105H HQ SECOND FLOOR SECURITY PLAN - AREA A

EY106H HQ SECOND FLOOR SECURITY PLAN - AREA B

EY107H HQ SECOND FLOOR SECURITY PLAN - AREA C

EY108H HQ SECOND FLOOR SECURITY PLAN - AREA D

EL101W WAREHOUSE FIRST FLOOR LIGHTING PLAN

EL601W LIGHTING FIXTURE AND CONTROLS SCHEDULE

EP101W WAREHOUSE FIRST FLOOR POWER PLAN

EP111W WAREHOUSE FIRST FLOOR EQUIPMENT CONNECTIONS PLAN

EP121W WAREHOUSE ROOF ELECTRICAL PLAN

EP601W WAREHOUSE EQUIPMENT CONNECTION SCHEDULE

EP701W WAREHOUSE POWER RISER DIAGRAM

ET101W WAREHOUSE FIRST FLOOR TELECOM PLAN

EY101W WAREHOUSE FIRST FLOOR SECURITY PLAN

EL101T TRAINING FIRST FLOOR LIGHTING PLAN

EL601T TRAINING LUMINAIRE SCHEDULE

EP101T TRAINING FIRST FLOOR POWER PLAN

EP701T TRAINING POWER RISER DIAGRAM

ET101T TRAINING FIRST FLOOR TELECOM PLAN

EY101T TRAINING FIRST FLOOR SECURITY PLAN

FP110W WAREHOUSE FIRST FLOOR FIRE PROTECTION PLAN

PLUMBING

P-001 PLUMBING LEGEND

PF101H HQ FOUNDATION PLAN - AREA A

PF102H HQ FOUNDATION PLAN - AREA B

PF103H HQ FOUNDATION PLAN - AREA C

PF104H HQ FOUNDATION PLAN - AREA D

PL101H HQ FIRST FLOOR PLAN - AREA A

PL102H HQ FIRST FLOOR PLAN - AREA B

PL103H HQ FIRST FLOOR PLAN - AREA C

PL104H HQ FIRST FLOOR PLAN - AREA D

PL105H HQ SECOND FLOOR PLAN - AREA A

PL106H HQ SECOND FLOOR PLAN - AREA B

PL107H HQ SECOND FLOOR PLAN - AREA C

PL108H HQ SECOND FLOOR PLAN - AREA D

P-601H SCHEDULES

PF101W WAREHOUSE FOUNDATION PLAN

PL101W WAREHOUSE FIRST FLOOR PLAN

P-601W SCHEDULES

PF101T TRAINING FOUNDATION PLAN

PL101T TRAINING FIRST FLOOR PLAN

P-601T SCHEDULES

MECHANICAL

M-001 MECHANICAL LEGEND

MZ101H HQ FIRST FLOOR OVERALL HVAC SYSTEMS PLAN

MZ102H HQ SECOND FLOOR OVERALL HVAC SYSTEMS PLAN

MZ103H HQ FIRST FLOOR OVERALL HVAC ZONING PLAN

MZ104H HQ SECOND FLOOR OVERALL HVAC ZONING PLAN

MH101H HQ FIRST FLOOR DUCTWORK PLAN - AREA A

MH102H HQ FIRST FLOOR DUCTWORK PLAN - AREA B

MH103H HQ FIRST FLOOR DUCTWORK PLAN - AREA C

MH104H HQ FIRST FLOOR DUCTWORK PLAN - AREA D

MH105H HQ SECOND FLOOR DUCTWORK PLAN - AREA A

MH106H HQ SECOND FLOOR DUCTWORK PLAN - AREA B

MH107H HQ SECOND FLOOR DUCTWORK PLAN - AREA C

MH108H HQ SECOND FLOOR DUCTWORK PLAN - AREA D

MP101H HQ FIRST FLOOR PIPING PLAN - AREA A

MP102H HQ FIRST FLOOR PIPING PLAN - AREA B

MP103H HQ FIRST FLOOR PIPING PLAN - AREA C

MP104H HQ FIRST FLOOR PIPING PLAN - AREA D

MP105H HQ SECOND FLOOR PIPING PLAN - AREA A

MP106H HQ SECOND FLOOR PIPING PLAN - AREA B

MP107H HQ SECOND FLOOR PIPING PLAN - AREA C

MP108H HQ SECOND FLOOR PIPING PLAN - AREA D

M-111H HQ OVERALL ROOF PLAN

M-401H HQ ENLARGED PLANS

M-601H HQ SCHEDULES

M-602H HQ SCHEDULES

M-603H HQ SCHEDULES

M-604H HQ SCHEDULES

M-701H HQ DIAGRAMS

MZ101W WAREHOUSE FIRST FLOOR HVAC ZONING PLAN

MH101W WAREHOUSE FIRST FLOOR PLAN - AREA A

MH102W WAREHOUSE FIRST FLOOR PLAN - AREA B

M-601W WAREHOUSE SCHEDULES

M-602W WAREHOUSE SCHEDULES

MH101T TRAINING FIRST FLOOR DUCTWORK PLAN

M-601T TRAINING SCHEDULES

ELECTRICAL

E-001 ELECTRICAL LEGEND, NOTES AND ABBREVIATIONS

EL101H HQ FIRST FLOOR LIGHTING PLAN - AREA A

EL102H HQ FIRST FLOOR LIGHTING PLAN - AREA B

EL103H HQ FIRST FLOOR LIGHTING PLAN - AREA C

EL104H HQ FIRST FLOOR LIGHTING PLAN - AREA D

EL105H HQ SECOND FLOOR LIGHTING PLAN - AREA A

EL106H HQ SECOND FLOOR LIGHTING PLAN - AREA B

EL107H HQ SECOND FLOOR LIGHTING PLAN - AREA C

EL108H HQ SECOND FLOOR LIGHTING PLAN - AREA D

EL601H HQ LIGHTING FIXTURE SCHEDULE

EL602H HQ LIGHTING CONTROL SCHEDULES

EL603H HQ LIGHTING CONTROL SCHEDULES

EL604H HQ LIGHTING CONTROL SCHEDULES

EL605H HQ LIGHTING CONTROL SCHEDULES

EP101H HQ FIRST FLOOR POWER PLAN - AREA A

EP102H HQ FIRST FLOOR POWER PLAN - AREA B

EP103H HQ FIRST FLOOR POWER PLAN - AREA C

EP104H HQ FIRST FLOOR POWER PLAN - AREA D

EP105H HQ SECOND FLOOR POWER PLAN - AREA A

EP106H HQ SECOND FLOOR POWER PLAN - AREA B

EP107H HQ SECOND FLOOR POWER PLAN - AREA C

EP701W WAREHOUSE POWER RISER DIAGRAM

ET101W WAREHOUSE FIRST FLOOR TELECOM PLAN

EY101W WAREHOUSE FIRST FLOOR SECURITY PLAN

EL101T TRAINING FIRST FLOOR LIGHTING PLAN

EL601T TRAINING LUMINAIRE SCHEDULE

EP101T TRAINING FIRST FLOOR POWER PLAN

EP701T TRAINING POWER RISER DIAGRAM

ET101T TRAINING FIRST FLOOR TELECOM PLAN

EY101T TRAINING FIRST FLOOR SECURITY PLAN

SF301H HQ FRAMING SECTIONS

SF501H HQ TYPICAL FRAMING DETAILS

SF502H HQ TYPICAL FRAMING DETAILS

S-001W WAREHOUSE STRUCTURAL NOTES

SB101W WAREHOUSE FOUNDATION PLAN

SB301W WAREHOUSE SECTIONS

SB501W WAREHOUSE TYPICAL DETAILS

S-001T TRAINING STRUCTURAL NOTES

SB101T TRAINING FOUNDATION PLAN

SB501T TRAINING TYPICAL FOUNDATION DETAILS

SF101T TRAINING ROOF FRAMING PLAN

SF501T TRAINING TYPICAL FRAMING DETAILS

ARCHITECTURAL

A-001 ARCHITECTURAL LEGEND, NOTES AND ABBREVIATIONS

AE001H HQ FIRST FLOOR OVERALL PLAN

AE002H HQ SECOND FLOOR OVERALL PLAN

AE101H HQ FIRST FLOOR PLAN - AREA A

AE102H HQ FIRST FLOOR PLAN - AREA B

AE103H HQ FIRST FLOOR PLAN - AREA C

AE104H HQ FIRST FLOOR PLAN - AREA D

AE105H HQ SECOND FLOOR PLAN - AREA A

AE106H HQ SECOND FLOOR PLAN - AREA B

AE107H HQ SECOND FLOOR PLAN - AREA C

AE108H HQ SECOND FLOOR PLAN - AREA D

AE110H HQ FIRST FLOOR REFLECTED CEILING PLAN - AREA A

AE111H HQ FIRST FLOOR REFLECTED CEILING PLAN - AREA B

AE112H HQ FIRST FLOOR REFLECTED CEILING PLAN - AREA C

AE113H HQ FIRST FLOOR REFLECTED CEILING PLAN - AREA D

AE114H HQ SECOND FLOOR REFLECTED CEILING PLAN - AREA A

AE115H HQ SECOND FLOOR REFLECTED CEILING PLAN - AREA B

AE116H HQ SECOND FLOOR REFLECTED CEILING PLAN - AREA C

AE117H HQ SECOND FLOOR REFLECTED CEILING PLAN - AREA D

AE120H HQ OVERALL ROOF PLAN

AE201H HQ OVERALL EXTERIOR ELEVATIONS

AE202H HQ EXTERIOR ELEVATIONS

AE203H HQ EXTERIOR ELEVATIONS

AE204H HQ EXTERIOR ELEVATIONS

AE301H HQ BUILDING SECTIONS

AE302H HQ BUILDING SECTIONS

AE310H HQ WALL SECTIONS

AE311H HQ WALL SECTIONS

AE312H HQ WALL SECTIONS

AE313H HQ WALL SECTIONS

AE403H HQ ENLARGED KITCHEN PLAN

AE404H HQ ENLARGED PLANS

AE501H PARTITION TYPES AND DETAILS

AE601H HQ DOOR SCHEDULE AND DOOR / FRAME TYPES

AE602H HQ DOOR SCHEDULE

AE101W WAREHOUSE FIRST FLOOR PLAN

AE110W WAREHOUSE REFLECTED CEILING PLAN

AE120W WAREHOUSE ROOF PLAN

AE201W WAREHOUSE EXTERIOR ELEVATIONS

AE301W WAREHOUSE BUILDING SECTIONS

AE310W WAREHOUSE WALL SECTIONS

AE601W WAREHOUSE DOOR SCHEDULE AND DOOR / FRAME TYPES

AE101T TRAINING FIRST FLOOR PLAN

AE110T TRAINING FIRST FLOOR REFLECTED CEILING PLAN

AE120T TRAINING ROOF PLAN

AE201T TRAINING EXTERIOR ELEVATIONS

AE301T TRAINING BUILDING SECTIONS

AE310T TRAINING WALL SECTIONS

AE601T TRAINING DOOR SCHEDULE

SF203H HQ BRACED FRAME ELEVATIONS

C R

CR

C R

CR

CRCR

C R

C R

C R

CR

C R

C R

CR

C

RCR

C R

C R

C R

C R C

R

CR

CR

C R

CR

C R

C

RC

R

CR

C R

C R

C R

CR

CR

C R

CR

CR

C R

C R

C R

CR

C R

C R

C R

CR

C

RC

R

DN

UP

BUILDING CODE SUMMARY

APPLICABLE CODES

BUILDING PURPOSE/OCCUPANCY:

CONSTRUCTION TYPE:

USE GROUP:

ALLOWABLE BUILDING HEIGHT:

-2018 VIRGINIA CONSTRUCTION CODE

-2018 VIRGINIA STATEWIDE FIRE PREVENTION CODE (VSFPC)

-2018 VIRGINIA PLUMBING CODE

-2018 VIRGINIA MECHANICAL CODE

-2018 VIRGINIA ENERGY CONSERVATION CODE - IECC 2018

-2018 VIRGINIA FUEL GAS CODE (VFGC)

-2017 NFPA 70 NATIONAL ELECTRICAL CODE

-2016 NFPA 13 STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS

-2016 NFPA 72 NATIONAL FIRE ALARM CODE

-2010 NFPA 110 STANDARD FOR EMERGENCY AND STANDBY POWER SYSTEMS

-2010 UL294 ACCESS CONTROLS SYSTEM UNITS

-2010 ADA STANDARDS FOR ACCESSIBLE DESIGN - DEPARTMENT OF JUSTICE (ADASAD) AND 2009 ICC A117.1

ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES

-BUSINESS - PUBLIC SAFETY COMPLEX WHICH CONTAINS OFFICE SPACE FOR FIRE AND

POLICE DEPARTMENTS. IN ADDITION THE BUILDING SERVES AS AN EMERGENCY

OPERATIONS CENTER AND CONTAINS A DISPATCH.

-TYPE IIB (VCC TABLE 504.3 AND TABLE 601)

BUSINESS GROUP B; OFFICES

TABLE 504.3 ALLOWABLE BUILDING HEIGHT IN FEET ABOVE GRADE PLANE

TYPE IIB SPRINKLERED:

ALLOWABLE: 75'-0"

ACTUAL: 47'-6"

TABLE 504.4 ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLANE

TYPE IIB SPRINKLERED

ALLOWABLE: 4 STORIES

ACTUAL: 2 STORY

ALLOWABLE BUILDING AREA

TABLE 506.2 ALLOWABLE AREA

TYPE IIB SPRINKLERED:

TABULATION OF BUILDING AREA

AREA, BUILDING. THE AREA INCLUDED WITHIN SURROUNDING EXTERIOR WALLS (OR

EXTERIOR WALLS AND FIRE WALLS) EXCLUSIVE OF VENT SHAFTS AND COURTS. AREAS

OF THE BUILDING NOT PROVIDED WITH SURROUNDING WALLS SHALL BE INCLUDED IN

THE BUILDING AREA IF SUCH AREAS ARE INCLUDED WITHIN THE HORIZONTAL

PROJECTION OF THE ROOF OR FLOOR ABOVE.

TABULATION OF GROSS SQUARE FOOTAGE

FIRE PROTECTION

THE BUILDING IS NOT SPRINKLERED. THE FIRE DETECTION SYSTEM IS PROVIDED IN

ACCORDANCE WITH VCC REQUIREMENTS. THE WHOLE BUILDING HAS A FIRE ALARM

SYSTEM

FIRE RESISTANT RATING REQUIREMENTS FOR BUILDING ELEMENTS(TABLE 601)

BEARING WALLS: INTERIOR/EXTERIOR 0 HOUR

NONBEARING WALLS & PARTITIONS: 0 HOUR EXTERIOR/INTERIOR

COLUMNS: 0 HOUR

BEAMS: 0 HOUR

FLOOR CONSTRUCTION: 0 HOUR

ROOF CONSTRUCTION: 0 HOUR

EXITS AND EXIT PASSAGEWAY: 1 HOUR

VERTICAL EXIT ENCLOSURE: 1 HOUR

VERTICAL SHAFTS 1- 3 STORIES: 1 HOUR

ACCESSIBLE MEANS OF EGRESS:

1009.1 ACCESSIBLE MEANS OF EGRESS REQUIRED. ACCESSIBLE MEANS OF EGRESS SHALL

COMPLY WITH THIS SECTION. ACCESSIBLE SPACES SHALL BE PROVIDED WITH NOT LESS

THAN ONE ACCESSIBLE MEANS OF EGRESS. WHERE MORE THAN ONE MEANS OF EGRESS

ARE REQUIRED BY SECTION 1006.2 OR 1006.3 FROM ANY ACCESSIBLE SPACE, EACH

ACCESSIBLE PORTION OF THE SPACE SHALL BE SERVED BY NOT LESS THAN TWO

ACCESSIBLE MEANS OF EGRESS.

MEANS OF EGRESS STAIRWAYS:

1005.3.1 STAIRWAYS. THE CAPACITY, IN INCHES, OF MEANS OF EGRESS STAIRWAYS SHALL BE CALCULATED BY MULTIPLYING THE OCCUPANT LOAD SERVED BY SUCH STAIRWAYS BY A MEANS OF EGRESS CAPACITY FACTOR OF

0.3 INCH PER OCCUPANT. WHERE STAIRWAYS SERVE MORE THAN ONE STORY, ONLY THE OCCUPANT LOAD OF EACH STORY CONSIDERED INDIVIDUALLY SHALL BE USED IN CALCULATING THE REQUIRED CAPACITY OF THE

STAIRWAYS SERVING THAT STORY.

EXCEPTIONS: 1. FOR OTHER THAN GROUP H AND I-2 OCCUPANCIES, THE CAPACITY, IN INCHES, OF MEANS OF EGRESS STAIRWAYS SHALL BE CALCULATED BY MULTIPLYING THE OCCUPANT LOAD SERVED BY SUCH STAIRWAYS BY A MEANS OF EGRESS CAPACITY FACTOR OF 0.2 INCH PER OCCUPANT IN BUILDINGS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM INSTALLED IN ACCORDANCE WITH SECTION 903.3.1.1 OR 903.3.1.2 AND AN EMERGENCY VOICE/ALARM COMMUNICATION SYSTEM IN ACCORDANCE WITH SECTION 907.5.2.2.

1009.1 ACCESSIBLE MEANS OF EGRESS REQUIRED. ACCESSIBLE MEANS OF EGRESS SHALL COMPLY WITH THIS SECTION. ACCESSIBLE SPACES SHALL BE PROVIDED WITH NOT LESS THAN ONE ACCESSIBLE MEANS OF EGRESS.

WHERE MORE THAN ONE MEANS OF EGRESS ARE REQUIRED BY SECTION 1006.2 OR 1006.3 FROM ANY ACCESSIBLE SPACE, EACH ACCESSIBLE PORTION OF THE SPACE SHALL BE SERVED BY NOT LESS THAN TWO ACCESSIBLE

MEANS OF EGRESS.

1011.2 WIDTH AND CAPACITY. THE REQUIRED CAPACITY OF STAIRWAYS SHALL BE DETERMINED AS SPECIFIED IN

SECTION 1005.1, BUT THE MINIMUM WIDTH SHALL

BE NOT LESS THAN 44 INCHES.

EXIT WIDTH STAIRWAYS FLOOR 2

775 OCCUPANTS / 4 EXITS = 120 X 0.2 = 39" REQUIRED WIDTH - 48" ACTUAL WIDTH

AREA INCREASE

BUSINESS B AREA INCREASE

If = [F/P - 0.25]W/30

NOTE IN THE ABOVE COMPUTATION FOR W THAT, WHERE THE ACTUAL WIDTH

EXCEEDS 30 FEET (9144 MM), A VALUE OF 30 FEET (9144 MM) IS USED AS REQUIRED

BY SECTION 506.3.2.

.75= [F/P - 0.25]30/30

Aa = At + (NS x If) 86,250 = 69,000+ (23,000 x .75) = TOTAL ALLOWABLE AREA INCREASE

ACTUAL: 58,263 SF

EGRESS AND OCCUPANCY

1010.1.1 SIZE OF DOORS. THE REQUIRED CAPACITY OF EACH DOOR OPENING SHALL BE SUFFICIENT FOR THE

OCCUPANT LOAD THEREOF AND SHALL PROVIDE A MINIMUM CLEAR WIDTH OF 32 INCHES.

1006.2.1 EGRESS BASED ON OCCUPANT LOAD AND COMMON PATH OF EGRESS TRAVEL DISTANCE. TWO EXITS OR EXIT ACCESS DOORWAYS FROM ANY SPACE SHALL BE PROVIDED WHERE THE DESIGN OCCUPANT LOAD OR THE COMMON PATH OF EGRESS TRAVEL DISTANCE EXCEEDS THE VALUES LISTED IN TABLE 1006.2.1.

1004.3 POSTING OF OCCUPANT LOAD. EVERY ROOM OR SPACE THAT IS AN ASSEMBLY OCCUPANCY SHALL HAVE THE OCCUPANT LOAD OF THE ROOM OR SPACE POSTED IN A CONSPICUOUS PLACE, NEAR THE MAIN EXIT OR EXIT ACCESS DOORWAY FROM THE ROOM OR SPACE. POSTED SIGNS SHALL BE OF AN APPROVED LEGIBLE PERMANENT DESIGN AND SHALL BE MAINTAINED BY THE OWNER OR THE OWNER’S AUTHORIZED AGENT.

PER TABLE 1006.2.1 SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY THE MAXIMUM OCCUPANT LOAD OF SPACE WITH ONE EXIT IS 49 AND THE MAXIMUM COMMON PATH OF EGRESS TRAVEL DISTANCE WITH SPRINKLER

SYSTEM IS 100 FEET

EXIT ACCESS TRAVEL DISTANCE

-PER TABLE 1017.2 EXIT ACCESS TRAVEL DISTANCE OCCUPANCY GROUP B BUILDINGS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION 903.3.1.1 CAN HAVE AN EXIT ACCESS

TRAVEL DISTANCE OF 300 FEET.

-EXIT ACCESS TRAVEL DISTANCE WITH ONE EXIT (TABLE 1006.3.2(2)) B 75 FEET

EXIT ACCESS:

-EGRESS THROUGH INTERVENING SPACES (VCC 1016.2,2): EGRESS FROM A ROOM OR SPACE SHALL NOT PASS

THROUGH ADJOINING OR

INTERVENING ROOMS OR AREAS, EXCEPT WHERE SUCH ADJOINING ROOMS OR AREAS AND THE AREA SERVED

ARE ACCESSORY TO

ONE OR THE OTHER, ARE NOT A GROUP H OCCUPANCY AND PROVIDE A DISCERNIBLE PATH OF EGRESS TRAVEL

TO AN EXIT

EGRESS CORRIDORS

-MINIMUM CORRIDOR WIDTH (VCC TABLE 1020.2): 44” REQUIRED OTHER THAN LISTED BELOW 24” ACCESS TO

MECHANICAL, PLUMBING,

OR ELECTRICAL SYSTEMS OR EQUIPMENT 36” WITH REQUIRED OCCUPANCY CAPACITY LESS THAN 50 -1020.4 DEAD ENDS. WHERE MORE THAN ONE EXIT OR EXIT ACCESS DOORWAY IS REQUIRED, THE EXIT ACCESS

SHALL BE ARRANGED

SUCH THAT THERE ARE NO DEAD ENDS IN CORRIDORS MORE THAN 20 FEET IN LENGTH.

EXCEPTIONS: 2. IN OCCUPANCIES IN GROUPS B, E, F, I-1, M, R-1, R-2, R-4, S AND U, WHERE THE BUILDING IS

EQUIPPED

THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION 903.3.1.1, THE LENGTH

OF THE DEAD-END

CORRIDORS SHALL NOT EXCEED 50 FEET.

FIRE EXTINGUISHERS

-MAXIMUM FLOOR AREA FOR EXTINGUISHER (VCC TABLE 906.3 (1)) ORDINARY HAZARD OCCUPANCY:11,250 SF -MAXIMUM FLOOR TRAVEL DISTANCE FOR EXTINGUISHER (VCC TABLE 906.3 (1)) ORDINARY HAZARD OCCUPANCY:75 FEET

-FIRE EXTINGUISHER CLASSIFICATION (VCC 906.1, 1. AND VCC TABLE 906.3 (1)) 2-ABC

-FIRE EXTINGUISHERS FOR FLAMMABLE OR COMBUSTIBLE LIQUIDS WITH DEPTHS LESS THAN OR EQUAL TO 0.25 INCH:

TYPE OF HAZARD BASIC MINIMUM EXTINGUISHER RATING MAXIMUM DISTANCE OF TRAVEL TO EXTINGUISHERS

LOW 5-B 30 FEET

10-B 50 FEET

ORDINARY 10-B 30 FEET

20-B 50 FEET

EXTRA 40-B 30 FEET

80-B 50 FEET

STORAGE S-2 AREA INCREASE

If = [F/P - 0.25]W/30

NOTE IN THE ABOVE COMPUTATION FOR W THAT, WHERE THE ACTUAL WIDTH

EXCEEDS 30 FEET (9144 MM), A VALUE OF 30 FEET (9144 MM) IS USED AS REQUIRED

BY SECTION 506.3.2.

.75= [F/P - 0.25]30/30

Aa = At + (NS x If) 97,500 = 78,000 + (26,000 x .75) = TOTAL ALLOWABLE AREA INCREASE

ACTUAL: 20,182 SF

ASSEMBLY A-3 AREA INCREASE

If = [F/P - 0.25]W/30

NOTE IN THE ABOVE COMPUTATION FOR W THAT, WHERE THE ACTUAL WIDTH

EXCEEDS 30 FEET (9144 MM), A VALUE OF 30 FEET (9144 MM) IS USED AS REQUIRED

BY SECTION 506.3.2.

.75= [F/P - 0.25]30/30

Aa = At + (NS x If) 35,625 = 28,500+ (9,500 x .75) = TOTAL ALLOWABLE AREA INCREASE

ACTUAL: 4,290 SF

508.4.2 ALLOWABLE BUILDING AREA. IN EACH STORY, THE BUILD-ING

AREA SHALL BE SUCH THAT THE SUM OF THE RATIOS OF THE

ACTUAL BUILDING AREA OF EACH SEPARATED OCCUPANCY DIVIDED

BY THE ALLOWABLE BUILDING AREA OF EACH SEPARATED OCCU-PANCY

SHALL NOT EXCEED 1

ASSEMBLY A-3 AREA INCREASE

58,263/86250 + 20,182/97,500 +4,290 /35,625

.68 + .2 +.12 = 1

S-2

A-3

B

B

VIRGINIA BEACH, VIRGINIA 23462

4525 MAIN STREET, SUITE 1400

757·455·5800

1 2 3 4 5 6

A

B

C

D

E

SHEET

B

C

D

E

DESIGN:

DRAWN:

REVIEW:

REVISIONSDESIGNER

A

PROFESSIONAL SEAL

NOT F

OR C

ONSTRUCTIO

N

5032 ROUSE DRIVE, SUITE 200

VIRGINIA BEACH, VA 23462-3764

757.490.9264

CIVIL CONSULTANT

C U s e rs

\B G

U R

C Z

Y N

S K

I\ O n e D ri v e

C la rk N e x s e n \D o c u m e n ts

\1

P o rt s m o u th C o m p le x H

Q A b g u rc z y n s k i_

C la rk N e x s e n c o m

.r v t

/1

/2

:2

:1

P

M

BUILDING CODE SUMMARY

Designer

Author

Checker

CN 1020535% SUBMITTAL DOCUMENTS

JANUARY 16, 2024

PORTSMOUTH PUBLIC SAFETY COMPLEX

CITY OF PORTSMOUTH

3701 WILLETT DR

PORTSMOUTH, VA 23707

GI002H

FLOOR EXISTING (SQ FT) RENOVATION (SQ FT) NEW (SQ FT) SUB-TOTAL (SQ FT)

FIRST FLOOR 0 SF 0 SF 82735 SF 82,735 SF

SECOND FLOOR 0 SF 0 SF 64798 SF 64,798 SF

TOTAL 0 SF 0 SF 147533 SF 147,533 SF

NOT TO SCALE

FIRST FLOOR ROOM DIAGRAM

NOT TO SCALE

SECOND FLOOR ROOM DIAGRAM

UP

W D

PF

A CCES SORY

S TORAGE

A REAS,

MECHA NICAL

E QUIP ME NT

ROOM

A SSE MBLY

W ITHOUT

FIX ED

S EATS

UNCONCENTRATED

(TA BLES

AND

CHA IRS)

B USINESS

A REAS

E DUCA TIONAL

CLA SSROOM

AREA

E XERCISE

ROOMS

K ITCHENS,

COMMERCIAL

LOCKER

ROOMS

W AREHOUSES

5,857 SF

B

40 OCC

H1002

H1014

H1009

H1021

ST2

ELV 1

H1121

H1110

H1106

H1042

H1046

H1111

H1038

H1116

H1028

H1100

ELV 2

H1202

H1204

H1218

H1209

H1220

H1223

H1222

H1246 H1247

H1248

ELV 3

ST3

H1302H1301

H1300

H1304 H1303

H1305

H1306

H1040

H1041

H1250

H1104

H1022

H1010

H1207

H1211

H1112

H1018

H1039

H1043

H1241 H1214

H1215

H1212 H1213H1210

H1238

H1227

H1224

H1234

H1226

H1232

H1237H1236H1235

H1228 H1229 H1230

H1231

H1233

H1239

H1244 H1243 H1242

H1245

H1006

H1005

H1001

H1000

ST1

H1003

H1004

H1205

H1221

H1036

H1037

H1035

H1033

H1032

H1030

H1029

H1034

H1031

H1120

H1114

H1115

H1122

H1118

H1117

H1109

H1108

H1103

H1102

H1047

H1045

H1219

H1216 H1217

H1251

H1208

H1024

H1107

H1019

H1016

H1013

H1011A

H1026

H1025

H1027

H1119

H1017

H1015

H1012

H1023

H1101

H1200

1,595 SF

B-W

4 OCC

72 SF

B-AS

1 OCC

1,659 SF

B-AS

6 OCC

598 SF

B-E

30 OCC

519 SF

B-E

26 OCC

3,735 SF

A3

249 OCC

1,804 SF

A3

121 OCC

224 SF

B-A3

15 OCC

213 SF

B-A3

15 OCC

208 SF

B-A3

14 OCC

3,622 SF

B-EX

73 OCC

465 SF

B-AS

2 OCC

120 SF

B-AS

1 OCC

287 SF

B-AS

1 OCC

53 SF

B-AS

1 OCC

157 SF

B-AS

1 OCC

156 SF

B-AS

1 OCC

937 SF

B-AS

4 OCC

193 SF

B-AS

1 OCC

336 SF

B-A3

23 OCC

703 SF

B-A3

47 OCC

198 SF

B-A3

14 OCC

385 SF

B-AS

2 OCC

179 SF

B-AS

1 OCC

179 SF

B-AS

1 OCC

137 SF

B-AS

1 OCC

404 SF

B-AS

2 OCC

268 SF

B-AS

1 OCC

112 SF

B-AS

1 OCC

669 SF

B-AS

3 OCC 20,182 SF

S2-W

41 OCC

661 SF

S2-B

5 OCC

855 SF

S2-B

6 OCC

1,169 SF

B-E

59 OCC

260 SF

B-AU

18 OCC

532 SF

B-AU

36 OCC

719 SF

B-K

4 OCC

1,666 SF

B-L

34 OCC

4,290 SF

A3

366 OCC

60 SF

B-AS

1 OCC

H1017A

440137

22057

220183

220183

220 37

220 37

220 1

220 1

220 2

833 SF

B-AS

3 OCC

75 SF

B-AS

1 OCC

51 SF

B-AS

1 OCC

729 SF

B-W

2 OCC

H1008

428 SF

B-AS

2 OCC

22,934 SF

B

145 OCC

22057

578 SF

B-AS

2 OCC

4,290 SF

A3

366 OCC

R-1

75 OCC

RESIDENTIAL

200 GSF / 1 PERSON

(VUSBC TABLE 1004.1.1)

ACTUAL OCCUPANCY

BASED ON COT SLEEPING

CONFIGURATION : 75 COTS

1. COORDINATE ALL FIRE EXTINGUISHERS LOCATIONS SHOWN ON PLANS W/

LOCAL FIRE OFFICIAL'S REQUIREMENTS.

2. PROVIDE & INSTALL ALL BLOCKING IN WALLS AS REQUIRED FOR

MOUNTING FIRE EXTINGUISHERS.

3. COORDINATE INSTALLATION REQUIREMENTS OF EXIT SIGNS, ALL

ASSOCIATED HARDWARE, JUNCTION BOXES, WIRING & REQUIRED EXIT

DEVICES W/ ELECTRICAL DRAWINGS & LOCAL INSPECTOR.

4. RATED WALLS AND PARTITIONS REQUIRED TO HAVE PROTECTED

OPENINGS SHALL BE PERMANENTLY STENCILED EVERY 10'-0" ABOVE THE

CEILING OR CONCEALED SPACE.

EXAMPLE:

• 1-HOUR RATED BARRIER - PROTECT ALL OPENINGS

EGRESS TRAVEL PATH

FIRE EXTINGUISHER CABINET

FIRE EXTINGUISHER BRACKET

FEC

SPACE AREA

SPACE NAME

OCCUPANT LOAD (PEOPLE)

PATH ID

FEB

SPACE NAME

9,876 SF 385 OCC

MAXIMUM OCCUPANT EGRESS LOAD

ACTUAL OCCUPANT EGRESS LOAD 220 120

USE GROUP LEGEND - AREAS BASED ON VUSBC TABLE 1004.5

B BUSINESS

B BUSINESS 150 GROSS

B-AS ACCESSORY STORAGE AREAS, MECHANICAL

EQUIPEMENT ROOM 300 GROSS

B-AU ASSEMBLY WITHOUT FIXED SEATS 15 NET

B-E CLASSROOM 20 NET

B-EX EXERCISE ROOMS 50 GROSS

B-L LOCKER ROOMS 50 GROSS

B-K KITCHENS, COMMERCIAL 200 GROSS

S-2 LOW HAZARD STORAGE

S2-W WAREHOUSE 500 GROSS

S2-B BUSINESS AREA 150 GROSS

A-3 ASSEMBLY

A-3 ASSEMBLY

SCALE: 1/16" = 1'-0"

FIRST FLOOR LIFE SAFETY PLAN GRAPHIC SCALE(S)

RATED PARTITION

LEGEND 1

1/16" = 1' - 0" 0 5' 10' 20' 30' 60'

VIRGINIA BEACH, VIRGINIA 23462

4525 MAIN STREET, SUITE 1400

757·455·5800

1 2 3 4 5 6

A

B

C

D

E

SHEET

B

C

D

E

DESIGN:

DRAWN:

REVIEW:

REVISIONSDESIGNER

A

PROFESSIONAL SEAL

NOT F

OR C

ONSTRUCTIO

N

5032 ROUSE DRIVE, SUITE 200

VIRGINIA BEACH, VA 23462-3764

757.490.9264

CIVIL CONSULTANT

C U s e rs

\B G

U R

C Z

Y N

S K

I\ O n e D ri v e

C la rk N e x s e n \D o c u m e n ts

\1

P o rt s m o u th C o m p le x H

Q A b g u rc z y n s k i_

C la rk N e x s e n c o m

.r v t

/1

/2

:2

:4

P

M

HQ FIRST FLOOR LIFE SAFETY PLAN

Designer

Author

Checker

CN 1020535% SUBMITTAL DOCUMENTS

JANUARY 16, 2024

PORTSMOUTH PUBLIC SAFETY COMPLEX

CITY OF PORTSMOUTH

3701 WILLETT DR

PORTSMOUTH, VA 23707

GI101H

LIFE SAFETY - OCCUPANT CALCULATION - FIRST FLOOR

LEVEL PATTERN FUNCTION OF SPACE

SF PER

PERSON OCCUPANCY SF TYPE AREA

*NUMBER OF

OCCUPANTS

FIRST FLOOR ACCESSORY STORAGE AREAS, MECHANICAL EQUIPMENT ROOM 300 GROSS 8,458 SF 41

FIRST FLOOR ASSEMBLY WITHOUT FIXED SEATS - UNCONCENTRATED (TABLES AND CHAIRS) 15 NET 12,502 SF 918

FIRST FLOOR BUSINESS AREAS 150 GROSS 30,307 SF 196

FIRST FLOOR EDUCATIONAL - CLASSROOM AREA 20 NET 2,286 SF 115

FIRST FLOOR EXERCISE ROOMS 50 GROSS 3,622 SF 73

FIRST FLOOR KITCHENS, COMMERCIAL 200 GROSS 719 SF 4

FIRST FLOOR LOCKER ROOMS 50 GROSS 1,666 SF 34

FIRST FLOOR WAREHOUSES 500 GROSS 22,505 SF 47

FIRST FLOOR TOTALS: 82,065 SF 1428

* NUMBER OF OCCUPANTS IS AN AGGREGATE AND IS A RESULT OF ROUNDING UP INDIVIDUAL AREAS

(SB)

SMOKE BARRIER (SB), SMOKE PARTITION

(SP), OR PARTITION CAPABLE OF

RESISTING THE PASSAGE OF SMOKE (S)

TWO HOUR FIRE RATING

ONE HOUR FIRE RATING

GENERAL NOTES

2-HOUR MIXED USE SEPERATION

FIRST FLOOR ROOM SCHEDULE

Number Name

H1002 PROPERTY & EVIDENCE

H1014 VEHICLE EXAMINATION

H1009 SHIPPING & RECEIVING

H1021 SALLY PORT

ST2 STAIR

ELV 1 ELEV.

H1121 DEFENSE TACTICS TRAINING CLASSROOM

H1110 VEHICLE SERVICES

H1106 FORCE SIMULATOR

H1042 RESIDENTIAL SIMULATOR

H1046 MEN'S TOILET

H1111 COMPUTER CLASSROOM

H1038 COMPUTER CLASSROOM

H1116 POLICE TRAINING OFFICE

H1028 FIRE TRAINING OFFICE

H1100 RECORDS

ELV 2 ELEV.

H1202 PUBLIC LOBBY

H1204 MULTIPURPOSE ROOM

H1218 MENS

H1209 PROFESSIONAL STANDARDS

H1220 BREIFING ROOM

H1223 MED. CONF.

H1222 MED. CONF.

H1246 EM. ELEC.

H1247 MAIN ELEC.

H1248 MECHANICAL

ELV 3 ELEV.

ST3 STAIR

H1302 MENS LOCKER ROOM

H1301 WOMENS LOCKER ROOM

H1300 COMMERCIAL KITCHEN & CAFETERIA

H1304 TELECOM

H1303 ELECTRICAL

H1305 GYM

H1306 BASKETBALL COURT

H1040 ELEC.

H1041 TELECOM

H1250 PREFUNCTION SPACE

H1310 OUTDOOR COVERED SEATING

H1104 CORRIDOR

H1022 PRIVATE CORRIDOR

H1010 PRIVATE CORRIDOR

H1207 FAMILY WAITING

H1211 VISITOR WAITING

H1112 ACADEMY CLASSROOM

H1018 FORENSICS LAB

H1039 BREAK

H1043 LRG. CONF.

H1241 MAG

H1214 RECORD STORAGE

H1215 LT OFFICE

H1212 INTERVIEW

H1213 POLYGRAPH

FIRST FLOOR ROOM SCHEDULE

Number Name

H1001 VESTIBULE

H1000 PUBLIC LOBBY

ST1 STAIR

H1003 GUN CAGE

H1004 DRUG CAGE

H1205 STORAGE

H1221 STO

H1036 EMS VIEWING

H1037 EMS TRAINING

H1035 SML. CONF.

H1033 STORAGE

H1032 LT OFFICE

H1030 CLINICAL

H1029 CAPTAIN

H1034 LT

H1031 STORAGE

H1120 STORAGE

H1114 STORAGE

H1115 ARMOR OFFICE

H1122 CADET BREAK ROOM

H1118 LT

H1117 SRGT

FIRST FLOOR ROOM SCHEDULE

Number Name

H1210 INTERVIEW

H1238 HEARING

H1227 PUBLIC TOILET

H1224 STORAGE

H1234 PRIVATE BATHROOM

H1226 BREAK ROOM

H1232 WAITING AREA

H1237 HEARING

H1236 HEARING

H1235 HEARING

H1228 VISITOR

H1229 VISITOR

H1230 VISITOR

H1231 VISITOR

H1233 VISITOR

H1239 HEARING

H1244 REGIONAL SUPERVISOR

H1243 CHIEF MAGISTRATE

H1242 CONFERENCE

H1245 PROBABLE CAUSE

H1006 OFFICER LOBBY

H1005 VESTIBULE

FIRST FLOOR ROOM SCHEDULE

Number Name

H1109 STORAGE

H1108 BREAK ROOM

H1103 RECORDS

H1102 PATROL GEAR ISSUE

H1047 VCIN TERMINAL

H1045 WOMEN'S TOILET

H1219 WOMENS

H1216 MENS

H1217 WOMENS

H1251 BREAK

H1208 JAN

H1024 VESTIBULE

H1107 CORRIDOR

H1019 FILE AND SUPPLY STORAGE

H1016 AFIS STORAGE

H1013 FORENSICS

H1011A QUARTERMASTER

H1026 STORAGE

H1025 ANIMAL SERVICES

H1027 VESTIBULE

H1119 STORAGE

H1017 FORENSIC TECH

FIRST FLOOR ROOM SCHEDULE

Number Name

H1015 EQUIPMENT STORAGE

H1012 VESTIBULE

H1023 CORRIDOR

H1101 POLY

H1200 ENTRANCE VESTIBULE

H1007 JAN

H1020 JAN

H1017A OFFICE

H1017B CORRIDOR

H1206 AV

H1201 STORAGE

H1240 MAGISTRATE

H1225 COAT

H1113 CORRIDOR

H1044 CORRIDOR

H1203 SRGT

H1008 FIRE PUMP

H1307 ELECTRICAL

H1309 TELECOM

H1308 TELECOM

H1120A STORAGE

H1105 VESTIBULE

H1312 CORRIDOR

H1311 CORRIDOR

H1011B CHANGING ROOM

H1011C CHANGING ROOM

DN

UP

45,948 SF

B

317 OCC

H2103

H2249

H2105

ELV 2

H2019

H2011

H2017H2003

H2008

H2125

ST1

ELV 4

H2010

H2023

ST2

H2119

H2054

H2108

H2022

H2021

H2129

H2218

H2214

H2217

H2311

ELV 3

ST3

H2238

H2314 H2312

H2235

H2236

H2323

H2028

H2000

H2106

H2234

H2233

H2315

H2102

H2104

H2209

H2206

H2131

H2208

H2207

H2130

H2203

H2221

H2226

H2224H2223

H2200H2201

H2222

H2202

H2215

H2211

H2205

H2020

H2013

H2014

H2012

H2016

H2015

H2018

H2056

H2057

H2065

H2055

H2101

H2100

H2247

H2306

H2246

H2303 H2301

H2248

H2310 H2308 H2307

H2305

H2135

H2136

H2213

H2210

H2212 H2216

H2313

H2229

H2006

H2007

H2044

H2004

H2005

H2024

H2026

H2025

H2237

H2317

H2324

H2325

H2320

H2053

H2318

H2319

H2321 H2322

H2316

H2001

H2219H2126

H2111

H2112

H2113

H2116

H2117

H2120

H2121

H2115

H2128

H2124

H2052

H2122

H2123

H2133

H2114B

H2118

H2309

H2302

H2304

H2232

H2228

H2225

H2227

H2241

H2244

H2242

H2245

H2240

H2243

H2220

H2009

H2127

H2051

H2034

H2045

H2043

H2033

H2042

H2027

H2030

H2029

H2031

H2032

H2050

H2049

H2048

H2047

H2046

H2035

H2036

H2037

H2038

H2039

H2041

H2040

299 SF

B-A3

20 OCC

303 SF

B-A3

21 OCC

252 SF

B-A3

17 OCC

150 SF

B-A3

11 OCC

296 SF

B-A3

20 OCC

326 SF

B-A3

22 OCC

621 SF

B-A3

42 OCC

342 SF

B-A3

23 OCC

392 SF

B-A3

27 OCC

182 SF

B-A3

13 OCC

209 SF

B-A3

14 OCC

416 SF

B-A3

28 OCC

411 SF

B-E

28 OCC

145 SF

B-A3

10 OCC

111 SF

B-A3

8 OCC

156 SF

B-AS

11 OCC

162 SF

B-AS

1 OCC

172 SF

B-AS

1 OCC

149 SF

B-A3

10 OCC

112 SF

B-AS

1 OCC

245 SF

B-AS

1 OCC

175 SF

B-AS

1 OCC

175 SF

B-AS

1 OCC

168 SF

B-AS

1 OCC

99 SF

B-AS

1 OCC

A CCES SORY STORAGE A RE AS , MECHA NICAL E QUIP MENT ROOM

A SS EMBLY WITHOUT FIXE D SE ATS - UNCONCENTRATED (TA BLES A ND CHA IRS)

B USINES S AREAS

1,071 SF

B-AS

4 OCC

151 SF

B-AS

1 OCC

150 SF

B-AS

1 OCC

114 SF

B-AS

1 OCC

109 SF

B-AS

1 OCC

185 SF

B-AS

1 OCC

164 SF

B-AS

1 OCC

192 SF

B-AS

1 OCC

200 SF

B-AS

1 OCC

88 SF

B-AS

1 OCC

42 SF

B-AS

1 OCC

220194

2 HOUR APPLIED

FIREPROOFING AT

COLUMNS, BEAMS, GIRDERS,

BRACED FRAMES, AND

UNDERSIDE OF FLOOR SLAB

ABOVE

1,566 SF

Area

1. COORDINATE ALL FIRE EXTINGUISHERS LOCATIONS SHOWN ON PLANS W/

LOCAL FIRE OFFICIAL'S REQUIREMENTS.

2. PROVIDE & INSTALL ALL BLOCKING IN WALLS AS REQUIRED FOR

MOUNTING FIRE EXTINGUISHERS.

3. COORDINATE INSTALLATION REQUIREMENTS OF EXIT SIGNS, ALL

ASSOCIATED HARDWARE, JUNCTION BOXES, WIRING & REQUIRED EXIT

DEVICES W/ ELECTRICAL DRAWINGS & LOCAL INSPECTOR.

4. RATED WALLS AND PARTITIONS REQUIRED TO HAVE PROTECTED

OPENINGS SHALL BE PERMANENTLY STENCILED EVERY 10'-0" ABOVE THE

CEILING OR CONCEALED SPACE.

EXAMPLE:

• 1-HOUR RATED BARRIER - PROTECT ALL OPENINGS

EGRESS TRAVEL PATH

FIRE EXTINGUISHER CABINET

FIRE EXTINGUISHER BRACKET

FEC

SPACE AREA

SPACE NAME

OCCUPANT LOAD (PEOPLE)

PATH ID

FEB

SPACE NAME

9,876 SF 385 OCC

MAXIMUM OCCUPANT EGRESS LOAD

ACTUAL OCCUPANT EGRESS LOAD 220 120

USE GROUP LEGEND - AREAS BASED ON VUSBC TABLE 1004.5

B BUSINESS

B BUSINESS 150 GROSS

B-AS ACCESSORY STORAGE AREAS, MECHANICAL

EQUIPEMENT ROOM 300 GROSS

B-AU ASSEMBLY WITHOUT FIXED SEATS 15 NET

B-E CLASSROOM 20 NET

B-EX EXERCISE ROOMS 50 GROSS

B-L LOCKER ROOMS 50 GROSS

B-K KITCHENS, COMMERCIAL 200 GROSS

S-2 LOW HAZARD STORAGE

S2-W WAREHOUSE 500 GROSS

S2-B BUSINESS AREA 150 GROSS

A-3 ASSEMBLY

A-3 ASSEMBLY

SCALE: 1/16" = 1'-0"

SECOND FLOOR LIFE SAFETY PLAN

VIRGINIA BEACH, VIRGINIA 23462

4525 MAIN STREET, SUITE 1400

757·455·5800

1 2 3 4 5 6

A

B

C

D

E

SHEET

B

C

D

E

DESIGN:

DRAWN:

REVIEW:

REVISIONSDESIGNER

A

PROFESSIONAL SEAL

NOT F

OR C

ONSTRUCTIO

N

5032 ROUSE DRIVE, SUITE 200

VIRGINIA BEACH, VA 23462-3764

757.490.9264

CIVIL CONSULTANT

C U s e rs

\B G

U R

C Z

Y N

S K

I\ O n e D ri v e

C la rk N e x s e n \D o c u m e n ts

\1

P o rt s m o u th C o m p le x H

Q A b g u rc z y n s k i_

C la rk N e x s e n c o m

.r v t

/1

/2

:2

:2

P

M

HQ SECOND FLOOR LIFE SAFETY PLAN

Designer

Author

Checker

CN 1020535% SUBMITTAL DOCUMENTS

JANUARY 16, 2024

PORTSMOUTH PUBLIC SAFETY COMPLEX

CITY OF PORTSMOUTH

3701 WILLETT DR

PORTSMOUTH, VA 23707

GI102H

* NUMBER OF OCCUPANTS IS AN AGGREGATE AND IS A RESULT OF ROUNDING UP INDIVIDUAL AREAS

LIFE SAFETY - OCCUPANT CALCULATION - SECOND FLOOR

LEVEL PATTERN OCCUPANCY

SF PER

PERSON OCCUPANCY SF TYPE AREA

*NUMBER OF

OCCUPANTS

SECOND FLOOR ACCESSORY STORAGE AREAS, MECHANICAL EQUIPMENT ROOM 300 GROSS 5,342 SF 22

SECOND FLOOR ASSEMBLY WITHOUT FIXED SEATS - UNCONCENTRATED (TABLES AND CHAIRS) 15 NET 6,355 SF 436

SECOND FLOOR BUSINESS AREAS 150 GROSS 45,948 SF 317

FIRST FLOOR TOTALS: 57,645 SF 775

SECOND FLOOR ROOM SCHEDULE

Number Name

H2103 CHIEF OF POLICE

H2249 ADMIN SERVICES

H2105 SM. CONF.

ELV 2 ELEV.

H2019 DISTRICT LTS

H2011 SPECIAL OPS

H2017 GANG SUPPRESSION

H2003 BREAK ROOM

H2008 MD. CONF.

H2125 STREET CRIMES

ST1 STAIR

ELV 4 ELEV.

H2010 CRIMINAL INVESTIGATIONS

H2023 NARCOTICS

ST2 STAIR

H2119 ROLL CALL

H2054 MEN'S TOILET

H2108 CRIME ANALYSIS

H2022 TELECOM

H2021 ELEC.

H2129 WELLNESS ROOM

H2218 MENS RESTROOM

H2214 STORAGE

H2217 FINANCIAL SUPPORT

H2311 FIRE MARSHALL

ELV 3 ELEV.

ST3 STAIR

H2238 I.T.

H2314 TELECOM

H2312 ELEC.

H2235 WELLNESS ROOM

H2236 MOTHERS ROOM

H2323 EOC

H2028 PRIVATE INTERVIEW CORE

H2000 MD. CONF.

H2106 SOFT INTERVIEW

H2234 REAL TIME CRIME

H2233 PRINT/COPY

H2315 BREAKOUT

H2102 POLICE CHIEF

H2104 EXECUTIVE CONF.

H2209 HR STORAGE

H2206 SUPERVISOR

H2131 POLYGRAPH

H2208 MEDICAL DIRECTOR

H2207 CLINCAL CARE

H2130 EMS

H2203 CAPTAIN

H2221 CHIEF

H2226 MED. CONF.

H2224 DEPUTY CHIEF

H2223 DEPUTY CHIEF

H2200 BATTALION CHIEF

H2201 BATTALION CHEIF

H2222 ADMIN SERVICES CORDINATOR

H2202 EMS MANAGER

H2215 SUPPLIES

H2211 HR

H2205 FISCAL MANAGER

H2020 STORAGE

H2013 STORAGE

H2014 LT

H2012 STORAGE

H2016 GSU STORAGE

SECOND FLOOR ROOM SCHEDULE

Number Name

H2015 INTERVIEW

H2018 LOBBY

H2056 PIO

H2057 PIO

H2065 ASSISTANT CHIEF

H2055 ASSISTANT CHIEF

H2101 ASSISTANT CHIEF

H2100 COPY/PRINT

H2247 LT

H2306 CAPT

H2246 EVIDENCE STORAGE

H2303 STORAGE

H2301 FIRE FIGHTER

H2248 DECON

H2310 FIRE FIGHTER

H2308 FIRE FIGHTER

H2307 FIRE FIGHTER

H2305 INTERVIEW ROOM

H2135 DIRECTOR

H2136 SUPERVISOR

H2213 MEETING

H2210 COPY/ PRINT

SECOND FLOOR ROOM SCHEDULE

Number Name

H2212 LOBBY

H2216 STORAGE

H2313 MEETING

H2229 BREAK ROOM

H2006 STORAGE

H2007 STORAGE

H2044 AV MONITORING

H2004 CAPTAIN

H2005 LT

H2024 STORAGE

H2026 LT

H2025 SURVEILLANCE EQUP.

H2237 I.T.

H2317 BREAKOUT

H2324 MANAGER

H2325 CAPTAIN

H2320 PLANNER

H2053 WOMEN'S TOILET

H2318 JOINT OPERATIONS

H2319 REPONSES AND RECOVERY

H2321 PIO

H2322 PLANNING

SECOND FLOOR ROOM SCHEDULE

Number Name

H2316 PLOTTER

H2001 LRG. CONF.

H2219 WOMENS RESTROOM

H2126 STORAGE

H2111 BREATHALYZER

H2112 FUGITIVE APPREHENSION

H2113 STORAGE

H2116 PLATOON 1

H2117 PLATOON 2

H2120 PLATOON 3

H2121 PLATOON 4

H2115 REPORT

H2128 MOTHERS

H2124 CAPT

H2052 SECURITY

H2122 LT

H2123 CAPT

H2133 ADMIN SERVICES

H2114B CORRIDOR

H2118 STORAGE

H2309 FIRE FIGHTER

H2302 FIRE FIGHTER

SECOND FLOOR ROOM SCHEDULE

Number Name

H2304 INTERVIEW ROOM

H2232 CLASSROOM

H2228 QUIET

H2225 MEETING

H2227 LOCKERS

H2241 MANAGER

H2244 QUALITY ASSURANCE

H2242 TRAINING

H2245 IT

H2240 DISPATCH

H2243 ADMIN

H2220 FIRE ADMIN

H2009 PRINT COPY

H2127 BREAK

H2051 INTERVIEW

H2034 INTERVIEW

H2045 INTERVIEW

H2043 INTERVIEW

H2033 AV MONITORING

H2042 AV MONITORING

H2027 VESTIBULE

H2030 HOLDING

SECOND FLOOR ROOM SCHEDULE

Number Name

H2029 HOLDING

H2031 HOLDING

H2032 HOLDING

H2050 HOLDING

H2049 HOLDING

H2048 HOLDING

H2047 HOLDING

H2046 HOLDING

H2035 HOLDING

H2036 HOLDING

H2037 HOLDING

H2038 HOLDING

H2039 HOLDING

H2041 UNISEX

H2040 UNISEX

H2239 OFFICE

H2107 SOFT INTERVIEW

H2109 CRIME ANALYSIS SVR

H2110 PLOTTER WORK AREA

H2230 BREAK

H2229 QUIET

H2231 STORAGE

H2114C ELEC

H2114A CORRIDOR

GRAPHIC SCALE(S)

RATED PARTITION

LIFE SAFETY LEGEND

1/16" = 1' - 0" 0 5' 10' 20' 30' 60'

(SB)

SMOKE BARRIER (SB), SMOKE PARTITION

(SP), OR PARTITION CAPABLE OF

RESISTING THE PASSAGE OF SMOKE (S)

TWO HOUR FIRE RATING

ONE HOUR FIRE RATING

GENERAL NOTES

V e n t H o o d

C R

CR

C R

CR

CRCR

C R

C R

C R

CR

C R

C R

CR

C R

CR

C R

C R

C R

C R

C R

CR

CR

C R

CR

C R

C R

C R

CR

C R

C R

C R

CR

CR

C R

CR

CR

C R

C R

C R

CR

C R

C R

C R

CR

C

RC

R

DN

UP

12002100

VIRGINIA BEACH, VIRGINIA 23462

4525 MAIN STREET, SUITE 1400

757·455·5800

1 2 3 4 5 6

A

B

C

D

E

SHEET

B

C

D

E

DESIGN:

DRAWN:

REVIEW:

REVISIONSDESIGNER

A

PROFESSIONAL SEAL

NOT F

OR C

ONSTRUCTIO

N

5032 ROUSE DRIVE, SUITE 200

VIRGINIA BEACH, VA 23462-3764

757.490.9264

CIVIL CONSULTANT

C U s e rs

\B G

U R

C Z

Y N

S K

I\ O n e D ri v e

C la rk N e x s e n \D o c u m e n ts

\1

P o rt s m o u th C o m p le x H

Q A b g u rc z y n s k i_

C la rk N e x s e n c o m

.r v t

/1

/2

:2

:4

P

M

ROOM NUMBER DIAGRAMS

Designer

Author

Checker

CN 1020535% SUBMITTAL DOCUMENTS

JANUARY 16, 2024

PORTSMOUTH PUBLIC SAFETY COMPLEX

CITY OF PORTSMOUTH

3701 WILLETT DR

PORTSMOUTH, VA 23707

GI110H

NOT TO SCALE

FIRST FLOOR ROOM DIAGRAM

NOT TO SCALE

SECOND FLOOR ROOM DIAGRAM

1. THE BUILDING HAS TWO LEVELS, EACH WITH DISTINCT

AREAS. ON THE FIRST LEVEL, THE ROOM NUMBERS ARE

ORGANIZED INTO SECTIONS: 1000'S, 1100'S, 1200'S, AND

1300'S. ON THE SECOND LEVEL, THE ROOM NUMBERS ARE

ORGANIZED INTO SECTIONS: 2000'S, 2100'S, 2200'S, AND

2300'S.

2. THIS SYSTEMATIC ARRANGEMENT PROVIDES CLARITY IN

NAVIGATING THE BUILDING AND LOCATING SPECIFIC

ROOMS WITHIN EACH DESIGNATED AREA DURING

CONSTRUCTION. FINAL BUILDING NUMBERING FOR

SIGNAGE SUBJECT TO CHANGE.

GENERAL NOTES

EGRESS TRAVEL PATH

FIRE EXTINGUISHER CABINET

FIRE EXTINGUISHER BRACKET

FEC

SPACE AREA

SPACE NAME

OCCUPANT LOAD (PEOPLE)

PATH ID

FEB

SPACE NAME

9,876 SF 385 OCC

MAXIMUM OCCUPANT EGRESS LOAD

ACTUAL OCCUPANT EGRESS LOAD 220 120

6,779 SF

S-1

14 OCC

A CCES SORY

S TORAGE

A REAS,

MECHA NICAL

E QUIP ME NT

ROOM

B USINESS

A REAS

W AREHOUSES

6,429 SF

S-1

13 OCC

378 SF

S-1

1 OCC 808 SF

S-1

2 OCC

167 SF

S-1

1 OCC

29 SF

S-1

1 OCC

194 SF

S-1

1 OCC

194 SF

S-1

1 OCC

200 SF

S-1

1 OCC

194 SF

S-1

1 OCC

661 SF

S-1

2 OCC901 SF

S-1

2 OCC

431 SF

S-1

1 OCC40 SF

AS

1 OCC

74 SF

AS

1 OCC

74 SF

AS

1 OCC

521 SF

S-1

2 OCC

QUARTERMASTER

STORAGE

127W

CIVIL

DISTURBANCE

121W

PROPERTY &

EVIDENCE

STORAGE

126W

DISTRICT

LIEUTENANTS

STORAGE

118W

RESTROOM

124W

CORRIDOR

122W

TELECOM

119W

FIRE MARSHALL

STORAGE

114W

EMS TRAINING

STORAGE

116W

EMS DIVISION

STORAGE

115W

LOGISTICS

STORAGE

117W

VEHICLE

STORAGE

130W

VEHICLE

STORAGE

100W

VEHICLE

STORAGE

135W

VEHICLE

STORAGE

136W

SPECIAL OPS

STORAGE

128W

VEHICLE

STORAGE

105W

VEHICLE

STORAGE

104W

VEHICLE

STORAGE

103W

VEHICLE

STORAGE

101W

VEHICLE

STORAGE

129W

VEHICLE

STORAGE

133W

VEHICLE

STORAGE

132W

VEHICLE

STORAGE

134W

I.T. MONOPOLE

125W

ELEC

120W

VEHICLE

STORAGE

131W

VEHICLE

STORAGE

137W

LOGISTICS

OFFICES

106W

RESTROOM

123WCAPTAIN

109W

LT

108W

LT

107W

TURN OUT GEAR

113W

MAINTENCE

AREA

110W

SUPPLY

STORAGE

111W

CRAWL GEAR

STORAGE

112W

819 SF

B

6 OCC

393 SF

S-1

1 OCC

141' - 9"

TD-1

128' - 3"

TD-2

93' - 9"

TD-4

116' - 8"

TD-3

1,395 SF

B

10 OCC

JAN

137X

220 5 2205

220 21

2,123 SF

S-1

5 OCC

1. COORDINATE ALL FIRE EXTINGUISHERS LOCATIONS SHOWN ON PLANS

W/ LOCAL FIRE OFFICIAL'S REQUIREMENTS.

2. PROVIDE & INSTALL ALL BLOCKING IN WALLS AS REQUIRED FOR

MOUNTING FIRE EXTINGUISHERS.

3. COORDINATE INSTALLATION REQUIREMENTS OF EXIT SIGNS, ALL

ASSOCIATED HARDWARE, JUNCTION BOXES, WIRING & REQUIRED EXIT

DEVICES W/ ELECTRICAL DRAWINGS & LOCAL INSPECTOR.

4. RATED WALLS AND PARTITIONS REQUIRED TO HAVE PROTECTED

OPENINGS SHALL BE PERMANENTLY STENCILED EVERY 10'-0" ABOVE

THE CEILING OR CONCEALED SPACE.

EXAMPLE:

• 1-HOUR RATED BARRIER - PROTECT ALL OPENINGS

BUILDING CODE SUMMARY

APPLICABLE CODES

BUILDING PURPOSE/OCCUPANCY:

CONSTRUCTION TYPE:

USE GROUP:

ALLOWABLE BUILDING HEIGHT:

-2018 VIRGINIA CONSTRUCTION CODE

-2018 VIRGINIA STATEWIDE FIRE PREVENTION CODE (VSFPC)

-2018 VIRGINIA PLUMBING CODE

-2018 VIRGINIA MECHANICAL CODE

-2018 VIRGINIA ENERGY CONSERVATION CODE - IECC 2018

-2018 VIRGINIA FUEL GAS CODE (VFGC)

-2017 NFPA 70 NATIONAL ELECTRICAL CODE

-2016 NFPA 13 STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS

-2016 NFPA 72 NATIONAL FIRE ALARM CODE

-2010 NFPA 110 STANDARD FOR EMERGENCY AND STANDBY POWER SYSTEMS

-2010 UL294 ACCESS CONTROLS SYSTEM UNITS

-2010 ADA STANDARDS FOR ACCESSIBLE DESIGN - DEPARTMENT OF JUSTICE (ADASAD)

-2009 ICC A117.1 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES

-WAREHOUSE STORAGE SPACE FOR FIRE AND POLICE DEPARTMENTS.

-TYPE IIB (VCC TABLE 504.3 AND TABLE 601)

STORAGE GROUP S-1; WAREHOUSE

TABLE 504.3 ALLOWABLE BUILDING HEIGHT IN FEET ABOVE GRADE PLANE

TYPE IIB SPRINKLERED:

ALLOWABLE: 75'-0"

ACTUAL: 47'-6"

TABLE 504.4 ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLANE

TYPE IIB SPRINKLERED

ALLOWABLE: 4 STORIES

ACTUAL: 1 STORY

ALLOWABLE BUILDING AREA

TABLE 506.2 ALLOWABLE AREA

TYPE IIB NON SPRINKLERED:

ALLOWABLE: 69,000 SF

ACTUAL: 27,044

TABULATION OF BUILDING AREA

AREA, BUILDING. THE AREA INCLUDED WITHIN SURROUNDING EXTERIOR WALLS (OR EXTERIOR

WALLS AND FIRE WALLS) EXCLUSIVE OF VENT SHAFTS AND COURTS. AREAS OF THE BUILDING NOT PROVIDED WITH SURROUNDING WALLS SHALL BE INCLUDED IN THE BUILDING AREA IF SUCH AREAS

ARE INCLUDED WITHIN THE HORIZONTAL PROJECTION OF THE ROOF OR FLOOR ABOVE.

TABULATION OF GROSS SQUARE FOOTAGE

FIRE PROTECTION

THE BUILDING IS NOT SPRINKLERED. THE FIRE DETECTION SYSTEM IS PROVIDED IN ACCORDANCE

WITH VCC REQUIREMENTS. THE WHOLE BUILDING HAS A FIRE ALARM SYSTEM

FIRE RESISTANT RATING REQUIREMENTS

FOR BUILDING ELEMENTS(TABLE 601)

BEARING WALLS: INTERIOR/EXTERIOR 0 HOUR

NONBEARING WALLS & PARTITIONS: 0 HOUR EXTERIOR/INTERIOR

COLUMNS: 0 HOUR

BEAMS: 0 HOUR

FLOOR CONSTRUCTION: 0 HOUR

ROOF CONSTRUCTION: 0 HOUR

EXITS AND EXIT PASSAGEWAY: 1 HOUR

VERTICAL EXIT ENCLOSURE: 1 HOUR

VERTICAL SHAFTS 1- 3 STORIES: 1 HOUR

ACCESSIBLE MEANS OF EGRESS:

1009.1 ACCESSIBLE MEANS OF EGRESS REQUIRED. ACCESSIBLE MEANS OF EGRESS SHALL COMPLY WITH THIS SECTION. ACCESSIBLE SPACES SHALL BE PROVIDED WITH NOT LESS THAN ONE ACCESSIBLE MEANS OF EGRESS. WHERE MORE THAN ONE MEANS OF EGRESS ARE REQUIRED BY SECTION 1006.2 OR 1006.3 FROM ANY ACCESSIBLE SPACE, EACH ACCESSIBLE PORTION OF THE SPACE SHALL BE

SERVED BY NOT LESS THAN TWO ACCESSIBLE MEANS OF EGRESS.

EGRESS AND OCCUPANCY

1010.1.1 SIZE OF DOORS. THE REQUIRED CAPACITY OF EACH DOOR OPENING SHALL BE SUFFICIENT FOR THE

OCCUPANT LOAD THEREOF AND SHALL PROVIDE A MINIMUM CLEAR WIDTH OF 32 INCHES.

1006.2.1 EGRESS BASED ON OCCUPANT LOAD AND COMMON PATH OF EGRESS TRAVEL DISTANCE. TWO EXITS OR EXIT ACCESS DOORWAYS FROM ANY SPACE SHALL BE PROVIDED WHERE THE DESIGN OCCUPANT LOAD OR THE COMMON PATH OF EGRESS TRAVEL DISTANCE EXCEEDS THE VALUES LISTED IN TABLE 1006.2.1.

1004.3 POSTING OF OCCUPANT LOAD. EVERY ROOM OR SPACE THAT IS AN ASSEMBLY OCCUPANCY SHALL HAVE THE OCCUPANT LOAD OF THE ROOM OR SPACE POSTED IN A CONSPICUOUS PLACE, NEAR THE MAIN EXIT OR EXIT ACCESS DOORWAY FROM THE ROOM OR SPACE. POSTED SIGNS SHALL BE OF AN APPROVED LEGIBLE PERMANENT DESIGN AND SHALL BE MAINTAINED BY THE OWNER OR THE OWNER’S AUTHORIZED AGENT.

PER TABLE 1006.2.1 SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY THE MAXIMUM OCCUPANT LOAD OF SPACE WITH ONE EXIT IS 49 AND THE MAXIMUM COMMON PATH OF EGRESS TRAVEL DISTANCE WITH SPRINKLER

SYSTEM IS 100 FEET

EXIT ACCESS TRAVEL DISTANCE

-PER TABLE 1017.2 EXIT ACCESS TRAVEL DISTANCE OCCUPANCY GROUP B BUILDINGS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION 903.3.1.1 CAN HAVE AN EXIT ACCESS

TRAVEL DISTANCE OF 300 FEET.

-EXIT ACCESS TRAVEL DISTANCE WITH ONE EXIT (TABLE 1006.3.2(2)) B 75 FEET

EXIT ACCESS:

-EGRESS THROUGH INTERVENING SPACES (VCC 1016.2,2): EGRESS FROM A ROOM OR SPACE SHALL NOT PASS

THROUGH ADJOINING OR

INTERVENING ROOMS OR AREAS, EXCEPT WHERE SUCH ADJOINING ROOMS OR AREAS AND THE AREA SERVED ARE

ACCESSORY TO

ONE OR THE OTHER, ARE NOT A GROUP H OCCUPANCY AND PROVIDE A DISCERNIBLE PATH OF EGRESS TRAVEL TO

AN EXIT

EGRESS CORRIDORS

-MINIMUM CORRIDOR WIDTH (VCC TABLE 1020.2): 44” REQUIRED OTHER THAN LISTED BELOW 24” ACCESS TO MECHANICAL, PLUMBING, OR ELECTRICAL SYSTEMS OR EQUIPMENT 36” WITH REQUIRED OCCUPANCY CAPACITY

LESS THAN 50

-1020.4 DEAD ENDS. WHERE MORE THAN ONE EXIT OR EXIT ACCESS DOORWAY IS REQUIRED, THE EXIT ACCESS SHALL BE ARRANGED SUCH THAT THERE ARE NO DEAD ENDS IN CORRIDORS MORE THAN 20 FEET IN LENGTH.

EXCEPTIONS: 2. IN OCCUPANCIES IN GROUPS B, E, F, I-1, M, R-1, R-2, R-4, S AND U, WHERE THE BUILDING IS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION 903.3.1.1, THE

LENGTH OF THE DEAD-END CORRIDORS SHALL NOT EXCEED 50 FEET.

FIRE EXTINGUISHERS

TYPE OF HAZARD BASIC MINIMUM EXTINGUISHER RATING MAXIMUM DISTANCE OF TRAVEL TO EXTINGUISHERS

LOW 5-B 30 FEET

10-B 50 FEET

ORDINARY 10-B 30 FEET

20-B 50 FEET

EXTRA 40-B 30 FEET

80-B 50 FEET

-MAXIMUM FLOOR AREA FOR EXTINGUISHER (VCC TABLE 906.3 (1)) ORDINARY HAZARD OCCUPANCY:11,250 SF -MAXIMUM FLOOR TRAVEL DISTANCE FOR EXTINGUISHER (VCC TABLE 906.3 (1))…

This is the start of the file's text. The full file is on GovTribe.