This file contains preliminary architectural and structural drawings for the Portsmouth Public Safety Complex, a new 35% submittal document dated January 16, 2024, prepared by Clark Nexsen for the City of Portsmouth, Virginia, located at 3701 Willett Drive. The project encompasses three distinct buildings: a headquarters (HQ) facility with 147,533 gross square feet across two stories, a warehouse building with 27,044 square feet, and a training range facility with 13,747 square feet. The HQ building is designed as Type IIB construction serving as a public safety complex containing office space for fire and police departments, emergency operations center, and dispatch facilities. The warehouse provides storage for fire and police departments, while the training range serves as a shooting facility. The complex is designed to accommodate maximum occupancy loads of 1,203 people in the HQ building, 74 people in the warehouse, and 82 people in the training range. Design compliance follows the 2018 Virginia Construction Code, 2017 NFPA 70 National Electrical Code, 2016 NFPA 13 sprinkler standards, and 2010 ADA accessibility requirements.
The structural design utilizes steel ordinary concentrically braced frames for lateral load resistance, composite concrete slabs at elevated floors, and open-web steel joists. Foundations are designed for a net allowable bearing capacity of 4,000 PSF on undisturbed soil or engineered fill with rigid inclusions per geotechnical recommendations. The HQ building features 1-hour fire-rated exits and vertical enclosures with no sprinkler system but with fire detection and alarm systems throughout. The warehouse operates as non-sprinklered Type IIB construction with 0-hour fire ratings for most building elements. Design wind loads are based on 130 mph basic design wind speed for Risk Category IV structures, with seismic design for Seismic Design Category A. The preliminary drawings include comprehensive sheet indexes, life safety plans, structural notes, foundation and framing plans, architectural floor plans, reflected ceiling plans, exterior elevations, building sections, wall sections, mechanical, electrical, plumbing, fire protection, and telecom systems documentation to support the 35% design submittal phase.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
VIRGINIA BEACH, VIRGINIA 23462
4525 MAIN STREET, SUITE 1400
757·455·5800
1 2 3 4 5 6
A
B
C
D
E
SHEET
B
C
D
E
DESIGN:
DRAWN:
REVIEW:
REVISIONSDESIGNER
A
PROFESSIONAL SEAL
NOT F
OR C
ONSTRUCTIO
N
5032 ROUSE DRIVE, SUITE 200
VIRGINIA BEACH, VA 23462-3764
757.490.9264
CIVIL CONSULTANT
C U s e rs
\B G
U R
C Z
Y N
S K
I\ O n e D ri v e
C la rk N e x s e n \D o c u m e n ts
\1
P o rt s m o u th C o m p le x H
Q A b g u rc z y n s k i_
C la rk N e x s e n c o m
.r v t
/1
/2
:2
:5
P
M
COVER SHEET
Designer
Author
Checker
CN 1020535% SUBMITTAL DOCUMENTS
JANUARY 16, 2024
PORTSMOUTH PUBLIC SAFETY COMPLEX
CITY OF PORTSMOUTH
3701 WILLETT DR
PORTSMOUTH, VA 23707
G-001
N
PORTSMOUTH PUBLIC SAFETY COMPLEX
CITY OF PORTSMOUTH
35% SUBMITTAL DOCUMENTS
JANUARY 16, 2024
3701 WILLETT DR
PORTSMOUTH, VA 23707
SITE MAP
PROJECT SITE
VICINITY MAP
CONSTRUCTION MANAGER
x
OWNER
CITY OF PORTSMOUTH
ENGINEERING AND TECHNICAL SERVICES
801 CRAWFORD STREET, 4TH FLOOR
PORTSMOUTH, VIRGINIA 23704
PROJECT TEAM
MECHANICAL, PLUMBING, ELECTRICAL
AND FIRE PROTECTION ENGINEER
CLARK NEXSEN
4525 MAIN STREET, SUITE 1400
VIRGINIA BEACH, VA 23462
T: 757.455.5800 F: 757.455.5638
ARCHITECT
CLARK NEXSEN
4525 MAIN STREET, SUITE 1400
VIRGINIA BEACH, VA 23462
T: 757.455.5800 F: 757.455.5638
LANDSCAPE ARCHITECT
CLARK NEXSEN
4525 MAIN STREET, SUITE 1400
VIRGINIA BEACH, VA 23462
T: 757.455.5800 F: 757.455.5638
STRUCTURAL ENGINEER
CLARK NEXSEN
4525 MAIN STREET, SUITE 1400
VIRGINIA BEACH, VA 23462
T: 757.455.5800 F: 757.455.5638
PROJECT SITE
CIVIL ENGINEER
MSA
5032 ROUSE DRIVE, SUITE 200
VIRGINIA BEACH, VA 23462-3764
T: 757.490.9264
- SITE PACKAGE
1 2 3 4 5 6
C
D
E
C
D
E
PORTSMOUTH PUBLIC SAFETY COMPLEX
CITY OF PORTSMOUTH
PRELIMINARY DRAWINGS
JANUARY 16, 2024
3701 WILLETT DR
PORTSMOUTH, VA 23707
DETAIL / PLAN NUMBER
SHEET WHERE SHOWN
COLUMN GRID LINE
ELEVATION DATUM
+12'-0"
FIRST FLOOR
ROOM DESIGNATION
PLAN TITLE AND
NORTH ARROW
ELEVATION NUMBER
SHEET WHERE SHOWN
SECTION NUMBER
SHEET WHERE SHOWN
1E1
EXISTING COLUMN GRID LINE
A1
DETAIL NUMBER
SHEET NUMBER REFERENCE NOTED IN GENERAL NOTES ON SHEET
BUILDING
SHEET WHERE SHOWN
SECTION NUMBER
NAME
SCALE:
A1
NAME
SCALE:
TRUE NORTH INDICATOR
PLAN NORTH INDICATOR
ROOM NAME
BUILDING
3D
A1 / AE101A1 / AE101
A1
AE301
A1
AE201
A1
AE410
A1
A1
AE402
A3
A2A4
A1
AE301
A1
AE311
ADDITIONAL ID INFO
IF USED
VIEW REFERENCE
ELEVATION NUMBER
SHEET WHERE SHOWN
DETAIL /
ENLARGED PLAN
INTERIOR
ELEVATION
EXTERIOR
ELEVATION
BUILDING SECTION
DETAIL / WALL
SECTION
DETAIL SECTION
PHOTOGRAPH / 3D
VIEW REFERENCE
DETAIL, SECTION,
ELEVATION TITLE
REVISION TAG
A1 / AE101
ADJACENT AREA
REFERENCE 1
MATCHLINE
DEMOLITION KEYNOTENEW WORK KEYNOTE
VIRGINIA BEACH, VIRGINIA 23462
4525 MAIN STREET, SUITE 1400
757·455·5800
1 2 3 4 5 6
A
B
C
D
E
SHEET
B
C
D
E
DESIGN:
DRAWN:
REVIEW:
REVISIONSDESIGNER
A
PROFESSIONAL SEAL
NOT F
OR C
ONSTRUCTIO
N
5032 ROUSE DRIVE, SUITE 200
VIRGINIA BEACH, VA 23462-3764
757.490.9264
CIVIL CONSULTANT
C U s e rs
\B G
U R
C Z
Y N
S K
I\ O n e D ri v e
C la rk N e x s e n \D o c u m e n ts
\1
P o rt s m o u th C o m p le x G e n e ra l_ A b g u rc z y n s k i_
C la rk N e x s e n c o m
.r v t
/1
/2
:2
:0
P
M
SHEET INDEX AND GENERAL PROJECT
SYMBOLOGY
Designer
Author
Checker
CN 1020535% SUBMITTAL DOCUMENTS
JANUARY 16, 2024
PORTSMOUTH PUBLIC SAFETY COMPLEX
CITY OF PORTSMOUTH
3701 WILLETT DR
PORTSMOUTH, VA 23707
GI001
SHEET INDEX - VOLUME IGENERAL PROJECT SYMBOLOGY
SHEET
NUMBER SHEET NAME
SHEET
NUMBER SHEET NAME
GENERAL
G-001 COVER SHEET
GI001 SHEET INDEX AND GENERAL PROJECT SYMBOLOGY
GI002H BUILDING CODE SUMMARY
GI101H HQ FIRST FLOOR LIFE SAFETY PLAN
GI102H HQ SECOND FLOOR LIFE SAFETY PLAN
GI110H ROOM NUMBER DIAGRAMS
GI101W WAREHOUSE LIFE SAFETY PLAN
GI101T RANGE LIFE SAFETY PLAN
STRUCTURAL
S-001 STRUCTURAL NOTES
S-002 STRUCTURAL NOTES
S-001H HQ STRUCTURAL NOTES
SB101H HQ FOUNDATION PLAN - OVERALL
SB102H HQ FOUNDATION PLAN - AREA A
SB103H HQ FOUNDATION PLAN - AREA B
SB104H HQ FOUNDATION PLAN - AREA C
SB105H HQ FOUNDATION PLAN - AREA D
SB301H HQ FOUNDATION SECTIONS
SB501H HQ TYPICAL FOUNDATION DETAILS
SB502H HQ TYPICAL SLAB-ON-GRADE DETAILS
SF101H HQ SECOND FLOOR FRAMING PLAN - OVERALL
SF102H HQ SECOND FLOOR FRAMING PLAN - AREA A
SF103H HQ SECOND FLOOR FRAMING PLAN - AREA B
SF104H HQ SECOND FLOOR FRAMING PLAN - AREA C
SF105H HQ SECOND FLOOR FRAMING PLAN - AREA D
SF111H HQ ROOF FRAMING PLAN - OVERALL
SF112H HQ ROOF FRAMING PLAN - AREA A
SF113H HQ ROOF FRAMING PLAN - AREA B
SF114H HQ ROOF FRAMING PLAN - AREA C
SF115H HQ ROOF FRAMING PLAN - AREA D
SF116H HQ ROOF FRAMING PLAN - AREA C
SF117H HQ ROOF SCREENWALL FRAMING PLAN - AREA C
SF201H HQ BRACED FRAME ELEVATIONS
SF202H HQ BRACED FRAME ELEVATIONS
SF301H HQ FRAMING SECTIONS
SF501H HQ TYPICAL FRAMING DETAILS
SF502H HQ TYPICAL FRAMING DETAILS
S-001W WAREHOUSE STRUCTURAL NOTES
SB101W WAREHOUSE FOUNDATION PLAN
SB301W WAREHOUSE SECTIONS
SB501W WAREHOUSE TYPICAL DETAILS
S-001T TRAINING STRUCTURAL NOTES
SB101T TRAINING FOUNDATION PLAN
SB501T TRAINING TYPICAL FOUNDATION DETAILS
SF101T TRAINING ROOF FRAMING PLAN
SF501T TRAINING TYPICAL FRAMING DETAILS
ARCHITECTURAL
A-001 ARCHITECTURAL LEGEND, NOTES AND ABBREVIATIONS
AE001H HQ FIRST FLOOR OVERALL PLAN
AE002H HQ SECOND FLOOR OVERALL PLAN
AE101H HQ FIRST FLOOR PLAN - AREA A
AE102H HQ FIRST FLOOR PLAN - AREA B
AE103H HQ FIRST FLOOR PLAN - AREA C
AE104H HQ FIRST FLOOR PLAN - AREA D
AE105H HQ SECOND FLOOR PLAN - AREA A
AE106H HQ SECOND FLOOR PLAN - AREA B
AE107H HQ SECOND FLOOR PLAN - AREA C
AE108H HQ SECOND FLOOR PLAN - AREA D
AE110H HQ FIRST FLOOR REFLECTED CEILING PLAN - AREA A
AE111H HQ FIRST FLOOR REFLECTED CEILING PLAN - AREA B
AE112H HQ FIRST FLOOR REFLECTED CEILING PLAN - AREA C
AE113H HQ FIRST FLOOR REFLECTED CEILING PLAN - AREA D
AE114H HQ SECOND FLOOR REFLECTED CEILING PLAN - AREA A
AE115H HQ SECOND FLOOR REFLECTED CEILING PLAN - AREA B
AE116H HQ SECOND FLOOR REFLECTED CEILING PLAN - AREA C
AE117H HQ SECOND FLOOR REFLECTED CEILING PLAN - AREA D
AE120H HQ OVERALL ROOF PLAN
AE201H HQ OVERALL EXTERIOR ELEVATIONS
AE202H HQ EXTERIOR ELEVATIONS
AE203H HQ EXTERIOR ELEVATIONS
AE204H HQ EXTERIOR ELEVATIONS
AE301H HQ BUILDING SECTIONS
AE302H HQ BUILDING SECTIONS
AE310H HQ WALL SECTIONS
AE311H HQ WALL SECTIONS
AE312H HQ WALL SECTIONS
AE313H HQ WALL SECTIONS
AE403H HQ ENLARGED KITCHEN PLAN
AE404H HQ ENLARGED PLANS
AE501H PARTITION TYPES AND DETAILS
AE601H HQ DOOR SCHEDULE AND DOOR / FRAME TYPES
AE602H HQ DOOR SCHEDULE
AE101W WAREHOUSE FIRST FLOOR PLAN
AE110W WAREHOUSE REFLECTED CEILING PLAN
AE120W WAREHOUSE ROOF PLAN
AE201W WAREHOUSE EXTERIOR ELEVATIONS
AE301W WAREHOUSE BUILDING SECTIONS
AE310W WAREHOUSE WALL SECTIONS
AE601W WAREHOUSE DOOR SCHEDULE AND DOOR / FRAME TYPES
AE101T TRAINING FIRST FLOOR PLAN
AE110T TRAINING FIRST FLOOR REFLECTED CEILING PLAN
AE120T TRAINING ROOF PLAN
AE201T TRAINING EXTERIOR ELEVATIONS
AE301T TRAINING BUILDING SECTIONS
AE310T TRAINING WALL SECTIONS
AE601T TRAINING DOOR SCHEDULE
SHEET
NUMBER SHEET NAME
INTERIORS
IN601H HQ - FINISH SCHEDULE & NOTES
IN602H FINISH LEGEND & GENERAL FINISH NOTES
IN601W WAREHOUSE - FINISH SCHEDULE & NOTES
IN601T TRAINING - FINISH SCHEDULE & NOTES
FIRE PROTECTION
F-001 FIRE PROTECTION LEGEND
F-002 SEQUENCE OF OPERATIONS
FP101H HQ FIRST FLOOR FIRE PROTECTION PLAN - AREA A
FP102H HQ FIRST FLOOR FIRE PROTECTION PLAN - AREA B
FP103H HQ FIRST FLOOR FIRE PROTECTION PLAN - AREA C
FP104H HQ FIRST FLOOR FIRE PROTECTION PLAN - AREA D
FP105H HQ SECOND FLOOR FIRE PROTECTION PLAN - AREA A
FP106H HQ SECOND FLOOR FIRE PROTECTION PLAN - AREA B
FP107H HQ SECOND FLOOR FIRE PROTECTION PLAN - AREA C
FP108H HQ SECOND FLOOR FIRE PROTECTION PLAN - AREA D
FP401H HQ ENLARGED FIRE PUMP ROOM
PLUMBING
P-001 PLUMBING LEGEND
PF101H HQ FOUNDATION PLAN - AREA A
PF102H HQ FOUNDATION PLAN - AREA B
PF103H HQ FOUNDATION PLAN - AREA C
PF104H HQ FOUNDATION PLAN - AREA D
PL101H HQ FIRST FLOOR PLAN - AREA A
PL102H HQ FIRST FLOOR PLAN - AREA B
PL103H HQ FIRST FLOOR PLAN - AREA C
PL104H HQ FIRST FLOOR PLAN - AREA D
PL105H HQ SECOND FLOOR PLAN - AREA A
PL106H HQ SECOND FLOOR PLAN - AREA B
PL107H HQ SECOND FLOOR PLAN - AREA C
PL108H HQ SECOND FLOOR PLAN - AREA D
P-601H SCHEDULES
PF101W WAREHOUSE FOUNDATION PLAN
PL101W WAREHOUSE FIRST FLOOR PLAN
P-601W SCHEDULES
PF101T TRAINING FOUNDATION PLAN
PL101T TRAINING FIRST FLOOR PLAN
P-601T SCHEDULES
MECHANICAL
M-001 MECHANICAL LEGEND
MZ101H HQ FIRST FLOOR OVERALL HVAC SYSTEMS PLAN
MZ102H HQ SECOND FLOOR OVERALL HVAC SYSTEMS PLAN
MZ103H HQ FIRST FLOOR OVERALL HVAC ZONING PLAN
MZ104H HQ SECOND FLOOR OVERALL HVAC ZONING PLAN
MH101H HQ FIRST FLOOR DUCTWORK PLAN - AREA A
MH102H HQ FIRST FLOOR DUCTWORK PLAN - AREA B
MH103H HQ FIRST FLOOR DUCTWORK PLAN - AREA C
MH104H HQ FIRST FLOOR DUCTWORK PLAN - AREA D
MH105H HQ SECOND FLOOR DUCTWORK PLAN - AREA A
MH106H HQ SECOND FLOOR DUCTWORK PLAN - AREA B
MH107H HQ SECOND FLOOR DUCTWORK PLAN - AREA C
MH108H HQ SECOND FLOOR DUCTWORK PLAN - AREA D
MP101H HQ FIRST FLOOR PIPING PLAN - AREA A
MP102H HQ FIRST FLOOR PIPING PLAN - AREA B
MP103H HQ FIRST FLOOR PIPING PLAN - AREA C
MP104H HQ FIRST FLOOR PIPING PLAN - AREA D
MP105H HQ SECOND FLOOR PIPING PLAN - AREA A
MP106H HQ SECOND FLOOR PIPING PLAN - AREA B
MP107H HQ SECOND FLOOR PIPING PLAN - AREA C
MP108H HQ SECOND FLOOR PIPING PLAN - AREA D
M-111H HQ OVERALL ROOF PLAN
M-401H HQ ENLARGED PLANS
M-601H HQ SCHEDULES
M-602H HQ SCHEDULES
M-603H HQ SCHEDULES
M-604H HQ SCHEDULES
M-701H HQ DIAGRAMS
MZ101W WAREHOUSE FIRST FLOOR HVAC ZONING PLAN
MH101W WAREHOUSE FIRST FLOOR PLAN - AREA A
MH102W WAREHOUSE FIRST FLOOR PLAN - AREA B
M-601W WAREHOUSE SCHEDULES
M-602W WAREHOUSE SCHEDULES
MH101T TRAINING FIRST FLOOR DUCTWORK PLAN
M-601T TRAINING SCHEDULES
ELECTRICAL
E-001 ELECTRICAL LEGEND, NOTES AND ABBREVIATIONS
EL101H HQ FIRST FLOOR LIGHTING PLAN - AREA A
EL102H HQ FIRST FLOOR LIGHTING PLAN - AREA B
EL103H HQ FIRST FLOOR LIGHTING PLAN - AREA C
EL104H HQ FIRST FLOOR LIGHTING PLAN - AREA D
EL105H HQ SECOND FLOOR LIGHTING PLAN - AREA A
EL106H HQ SECOND FLOOR LIGHTING PLAN - AREA B
EL107H HQ SECOND FLOOR LIGHTING PLAN - AREA C
EL108H HQ SECOND FLOOR LIGHTING PLAN - AREA D
EL601H HQ LIGHTING FIXTURE SCHEDULE
EL602H HQ LIGHTING CONTROL SCHEDULES
EL603H HQ LIGHTING CONTROL SCHEDULES
EL604H HQ LIGHTING CONTROL SCHEDULES
EL605H HQ LIGHTING CONTROL SCHEDULES
EP101H HQ FIRST FLOOR POWER PLAN - AREA A
EP102H HQ FIRST FLOOR POWER PLAN - AREA B
EP103H HQ FIRST FLOOR POWER PLAN - AREA C
EP104H HQ FIRST FLOOR POWER PLAN - AREA D
EP105H HQ SECOND FLOOR POWER PLAN - AREA A
EP106H HQ SECOND FLOOR POWER PLAN - AREA B
EP107H HQ SECOND FLOOR POWER PLAN - AREA C
SHEET
NUMBER SHEET NAME
EP108H HQ SECOND FLOOR POWER PLAN - AREA D
EP201H HQ FIRST FLOOR EQUIPMENT CONNECTIONS PLAN - AREA A
EP202H HQ FIRST FLOOR EQUIPMENT CONNECTIONS PLAN - AREA B
EP203H HQ FIRST FLOOR EQUIPMENT CONNECTIONS PLAN - AREA C
EP204H HQ FIRST FLOOR EQUIPMENT CONNECTIONS PLAN - AREA D
EP205H HQ SECOND FLOOR EQUIPMENT CONNECTIONS PLAN - AREA A
EP206H HQ SECOND FLOOR EQUIPMENT CONNECTIONS PLAN - AREA B
EP207H HQ SECOND FLOOR EQUIPMENT CONNECTIONS PLAN - AREA C
EP208H HQ SECOND FLOOR EQUIPMENT CONNECTIONS PLAN - AREA D
EP221H HQ ELECTRICAL ROOF PLAN - AREA A
EP222H HQ ELECTRICAL ROOF PLAN - AREA B
EP223H HQ ELECTRICAL ROOF PLAN - AREA C
EP224H HQ ELECTRICAL ROOF PLAN - AREA D
EP401H HQ ENLARGED POWER PLANS
EP402H HQ ENLARGED POWER PLANS
EP403H HQ ENLARGED POWER PLANS
EP601H HQ EQUIPMENT CONNECTION SCHEDULE
EP602H HQ EQUIPMENT CONNECTION SCHEDULE
EP603H HQ EQUIPMENT CONNECTION SCHEDULE
EP701H HQ PARTIAL POWER RISER DIAGRAM
EP702H HQ PARTIAL POWER RISER DIAGRAM
EP703H HQ PARTIAL POWER RISER DIAGRAM
EP704H HQ PARTIAL POWER RISER DIAGRAM
ET101H HQ FIRST FLOOR TELECOM PLAN - AREA A
ET102H HQ FIRST FLOOR TELECOM PLAN - AREA B
ET103H HQ FIRST FLOOR TELECOM PLAN - AREA C
ET104H HQ FIRST FLOOR TELECOM PLAN - AREA D
ET105H HQ SECOND FLOOR TELECOM PLAN - AREA A
ET106H HQ SECOND FLOOR TELECOM PLAN - AREA B
ET107H HQ SECOND FLOOR TELECOM PLAN - AREA C
ET108H HQ SECOND FLOOR TELECOM PLAN - AREA D
ET401H HQ ENLARGED TELECOM PLANS
ET402H HQ ENLARGED TELECOM PLANS
ET501H HQ TELECOM DETAILS
ET701H HQ TELECOM RISER DIAGRAMS
EY101H HQ FIRST FLOOR SECURITY PLAN - AREA A
EY102H HQ FIRST FLOOR SECURITY PLAN - AREA B
EY103H HQ FIRST FLOOR SECURITY PLAN - AREA C
EY104H HQ FIRST FLOOR SECURITY PLAN - AREA D
EY105H HQ SECOND FLOOR SECURITY PLAN - AREA A
EY106H HQ SECOND FLOOR SECURITY PLAN - AREA B
EY107H HQ SECOND FLOOR SECURITY PLAN - AREA C
EY108H HQ SECOND FLOOR SECURITY PLAN - AREA D
EL101W WAREHOUSE FIRST FLOOR LIGHTING PLAN
EL601W LIGHTING FIXTURE AND CONTROLS SCHEDULE
EP101W WAREHOUSE FIRST FLOOR POWER PLAN
EP111W WAREHOUSE FIRST FLOOR EQUIPMENT CONNECTIONS PLAN
EP121W WAREHOUSE ROOF ELECTRICAL PLAN
EP601W WAREHOUSE EQUIPMENT CONNECTION SCHEDULE
EP701W WAREHOUSE POWER RISER DIAGRAM
ET101W WAREHOUSE FIRST FLOOR TELECOM PLAN
EY101W WAREHOUSE FIRST FLOOR SECURITY PLAN
EL101T TRAINING FIRST FLOOR LIGHTING PLAN
EL601T TRAINING LUMINAIRE SCHEDULE
EP101T TRAINING FIRST FLOOR POWER PLAN
EP701T TRAINING POWER RISER DIAGRAM
ET101T TRAINING FIRST FLOOR TELECOM PLAN
EY101T TRAINING FIRST FLOOR SECURITY PLAN
FP110W WAREHOUSE FIRST FLOOR FIRE PROTECTION PLAN
PLUMBING
P-001 PLUMBING LEGEND
PF101H HQ FOUNDATION PLAN - AREA A
PF102H HQ FOUNDATION PLAN - AREA B
PF103H HQ FOUNDATION PLAN - AREA C
PF104H HQ FOUNDATION PLAN - AREA D
PL101H HQ FIRST FLOOR PLAN - AREA A
PL102H HQ FIRST FLOOR PLAN - AREA B
PL103H HQ FIRST FLOOR PLAN - AREA C
PL104H HQ FIRST FLOOR PLAN - AREA D
PL105H HQ SECOND FLOOR PLAN - AREA A
PL106H HQ SECOND FLOOR PLAN - AREA B
PL107H HQ SECOND FLOOR PLAN - AREA C
PL108H HQ SECOND FLOOR PLAN - AREA D
P-601H SCHEDULES
PF101W WAREHOUSE FOUNDATION PLAN
PL101W WAREHOUSE FIRST FLOOR PLAN
P-601W SCHEDULES
PF101T TRAINING FOUNDATION PLAN
PL101T TRAINING FIRST FLOOR PLAN
P-601T SCHEDULES
MECHANICAL
M-001 MECHANICAL LEGEND
MZ101H HQ FIRST FLOOR OVERALL HVAC SYSTEMS PLAN
MZ102H HQ SECOND FLOOR OVERALL HVAC SYSTEMS PLAN
MZ103H HQ FIRST FLOOR OVERALL HVAC ZONING PLAN
MZ104H HQ SECOND FLOOR OVERALL HVAC ZONING PLAN
MH101H HQ FIRST FLOOR DUCTWORK PLAN - AREA A
MH102H HQ FIRST FLOOR DUCTWORK PLAN - AREA B
MH103H HQ FIRST FLOOR DUCTWORK PLAN - AREA C
MH104H HQ FIRST FLOOR DUCTWORK PLAN - AREA D
MH105H HQ SECOND FLOOR DUCTWORK PLAN - AREA A
MH106H HQ SECOND FLOOR DUCTWORK PLAN - AREA B
MH107H HQ SECOND FLOOR DUCTWORK PLAN - AREA C
MH108H HQ SECOND FLOOR DUCTWORK PLAN - AREA D
MP101H HQ FIRST FLOOR PIPING PLAN - AREA A
MP102H HQ FIRST FLOOR PIPING PLAN - AREA B
MP103H HQ FIRST FLOOR PIPING PLAN - AREA C
MP104H HQ FIRST FLOOR PIPING PLAN - AREA D
MP105H HQ SECOND FLOOR PIPING PLAN - AREA A
MP106H HQ SECOND FLOOR PIPING PLAN - AREA B
MP107H HQ SECOND FLOOR PIPING PLAN - AREA C
MP108H HQ SECOND FLOOR PIPING PLAN - AREA D
M-111H HQ OVERALL ROOF PLAN
M-401H HQ ENLARGED PLANS
M-601H HQ SCHEDULES
M-602H HQ SCHEDULES
M-603H HQ SCHEDULES
M-604H HQ SCHEDULES
M-701H HQ DIAGRAMS
MZ101W WAREHOUSE FIRST FLOOR HVAC ZONING PLAN
MH101W WAREHOUSE FIRST FLOOR PLAN - AREA A
MH102W WAREHOUSE FIRST FLOOR PLAN - AREA B
M-601W WAREHOUSE SCHEDULES
M-602W WAREHOUSE SCHEDULES
MH101T TRAINING FIRST FLOOR DUCTWORK PLAN
M-601T TRAINING SCHEDULES
ELECTRICAL
E-001 ELECTRICAL LEGEND, NOTES AND ABBREVIATIONS
EL101H HQ FIRST FLOOR LIGHTING PLAN - AREA A
EL102H HQ FIRST FLOOR LIGHTING PLAN - AREA B
EL103H HQ FIRST FLOOR LIGHTING PLAN - AREA C
EL104H HQ FIRST FLOOR LIGHTING PLAN - AREA D
EL105H HQ SECOND FLOOR LIGHTING PLAN - AREA A
EL106H HQ SECOND FLOOR LIGHTING PLAN - AREA B
EL107H HQ SECOND FLOOR LIGHTING PLAN - AREA C
EL108H HQ SECOND FLOOR LIGHTING PLAN - AREA D
EL601H HQ LIGHTING FIXTURE SCHEDULE
EL602H HQ LIGHTING CONTROL SCHEDULES
EL603H HQ LIGHTING CONTROL SCHEDULES
EL604H HQ LIGHTING CONTROL SCHEDULES
EL605H HQ LIGHTING CONTROL SCHEDULES
EP101H HQ FIRST FLOOR POWER PLAN - AREA A
EP102H HQ FIRST FLOOR POWER PLAN - AREA B
EP103H HQ FIRST FLOOR POWER PLAN - AREA C
EP104H HQ FIRST FLOOR POWER PLAN - AREA D
EP105H HQ SECOND FLOOR POWER PLAN - AREA A
EP106H HQ SECOND FLOOR POWER PLAN - AREA B
EP107H HQ SECOND FLOOR POWER PLAN - AREA C
EP701W WAREHOUSE POWER RISER DIAGRAM
ET101W WAREHOUSE FIRST FLOOR TELECOM PLAN
EY101W WAREHOUSE FIRST FLOOR SECURITY PLAN
EL101T TRAINING FIRST FLOOR LIGHTING PLAN
EL601T TRAINING LUMINAIRE SCHEDULE
EP101T TRAINING FIRST FLOOR POWER PLAN
EP701T TRAINING POWER RISER DIAGRAM
ET101T TRAINING FIRST FLOOR TELECOM PLAN
EY101T TRAINING FIRST FLOOR SECURITY PLAN
SF301H HQ FRAMING SECTIONS
SF501H HQ TYPICAL FRAMING DETAILS
SF502H HQ TYPICAL FRAMING DETAILS
S-001W WAREHOUSE STRUCTURAL NOTES
SB101W WAREHOUSE FOUNDATION PLAN
SB301W WAREHOUSE SECTIONS
SB501W WAREHOUSE TYPICAL DETAILS
S-001T TRAINING STRUCTURAL NOTES
SB101T TRAINING FOUNDATION PLAN
SB501T TRAINING TYPICAL FOUNDATION DETAILS
SF101T TRAINING ROOF FRAMING PLAN
SF501T TRAINING TYPICAL FRAMING DETAILS
ARCHITECTURAL
A-001 ARCHITECTURAL LEGEND, NOTES AND ABBREVIATIONS
AE001H HQ FIRST FLOOR OVERALL PLAN
AE002H HQ SECOND FLOOR OVERALL PLAN
AE101H HQ FIRST FLOOR PLAN - AREA A
AE102H HQ FIRST FLOOR PLAN - AREA B
AE103H HQ FIRST FLOOR PLAN - AREA C
AE104H HQ FIRST FLOOR PLAN - AREA D
AE105H HQ SECOND FLOOR PLAN - AREA A
AE106H HQ SECOND FLOOR PLAN - AREA B
AE107H HQ SECOND FLOOR PLAN - AREA C
AE108H HQ SECOND FLOOR PLAN - AREA D
AE110H HQ FIRST FLOOR REFLECTED CEILING PLAN - AREA A
AE111H HQ FIRST FLOOR REFLECTED CEILING PLAN - AREA B
AE112H HQ FIRST FLOOR REFLECTED CEILING PLAN - AREA C
AE113H HQ FIRST FLOOR REFLECTED CEILING PLAN - AREA D
AE114H HQ SECOND FLOOR REFLECTED CEILING PLAN - AREA A
AE115H HQ SECOND FLOOR REFLECTED CEILING PLAN - AREA B
AE116H HQ SECOND FLOOR REFLECTED CEILING PLAN - AREA C
AE117H HQ SECOND FLOOR REFLECTED CEILING PLAN - AREA D
AE120H HQ OVERALL ROOF PLAN
AE201H HQ OVERALL EXTERIOR ELEVATIONS
AE202H HQ EXTERIOR ELEVATIONS
AE203H HQ EXTERIOR ELEVATIONS
AE204H HQ EXTERIOR ELEVATIONS
AE301H HQ BUILDING SECTIONS
AE302H HQ BUILDING SECTIONS
AE310H HQ WALL SECTIONS
AE311H HQ WALL SECTIONS
AE312H HQ WALL SECTIONS
AE313H HQ WALL SECTIONS
AE403H HQ ENLARGED KITCHEN PLAN
AE404H HQ ENLARGED PLANS
AE501H PARTITION TYPES AND DETAILS
AE601H HQ DOOR SCHEDULE AND DOOR / FRAME TYPES
AE602H HQ DOOR SCHEDULE
AE101W WAREHOUSE FIRST FLOOR PLAN
AE110W WAREHOUSE REFLECTED CEILING PLAN
AE120W WAREHOUSE ROOF PLAN
AE201W WAREHOUSE EXTERIOR ELEVATIONS
AE301W WAREHOUSE BUILDING SECTIONS
AE310W WAREHOUSE WALL SECTIONS
AE601W WAREHOUSE DOOR SCHEDULE AND DOOR / FRAME TYPES
AE101T TRAINING FIRST FLOOR PLAN
AE110T TRAINING FIRST FLOOR REFLECTED CEILING PLAN
AE120T TRAINING ROOF PLAN
AE201T TRAINING EXTERIOR ELEVATIONS
AE301T TRAINING BUILDING SECTIONS
AE310T TRAINING WALL SECTIONS
AE601T TRAINING DOOR SCHEDULE
SF203H HQ BRACED FRAME ELEVATIONS
C R
CR
C R
CR
CRCR
C R
C R
C R
CR
C R
C R
CR
C
RCR
C R
C R
C R
C R C
R
CR
CR
C R
CR
C R
C
RC
R
CR
C R
C R
C R
CR
CR
C R
CR
CR
C R
C R
C R
CR
C R
C R
C R
CR
C
RC
R
DN
UP
BUILDING CODE SUMMARY
APPLICABLE CODES
BUILDING PURPOSE/OCCUPANCY:
CONSTRUCTION TYPE:
USE GROUP:
ALLOWABLE BUILDING HEIGHT:
-2018 VIRGINIA CONSTRUCTION CODE
-2018 VIRGINIA STATEWIDE FIRE PREVENTION CODE (VSFPC)
-2018 VIRGINIA PLUMBING CODE
-2018 VIRGINIA MECHANICAL CODE
-2018 VIRGINIA ENERGY CONSERVATION CODE - IECC 2018
-2018 VIRGINIA FUEL GAS CODE (VFGC)
-2017 NFPA 70 NATIONAL ELECTRICAL CODE
-2016 NFPA 13 STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS
-2016 NFPA 72 NATIONAL FIRE ALARM CODE
-2010 NFPA 110 STANDARD FOR EMERGENCY AND STANDBY POWER SYSTEMS
-2010 UL294 ACCESS CONTROLS SYSTEM UNITS
-2010 ADA STANDARDS FOR ACCESSIBLE DESIGN - DEPARTMENT OF JUSTICE (ADASAD) AND 2009 ICC A117.1
ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES
-BUSINESS - PUBLIC SAFETY COMPLEX WHICH CONTAINS OFFICE SPACE FOR FIRE AND
POLICE DEPARTMENTS. IN ADDITION THE BUILDING SERVES AS AN EMERGENCY
OPERATIONS CENTER AND CONTAINS A DISPATCH.
-TYPE IIB (VCC TABLE 504.3 AND TABLE 601)
BUSINESS GROUP B; OFFICES
TABLE 504.3 ALLOWABLE BUILDING HEIGHT IN FEET ABOVE GRADE PLANE
TYPE IIB SPRINKLERED:
ALLOWABLE: 75'-0"
ACTUAL: 47'-6"
TABLE 504.4 ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLANE
TYPE IIB SPRINKLERED
ALLOWABLE: 4 STORIES
ACTUAL: 2 STORY
ALLOWABLE BUILDING AREA
TABLE 506.2 ALLOWABLE AREA
TYPE IIB SPRINKLERED:
TABULATION OF BUILDING AREA
AREA, BUILDING. THE AREA INCLUDED WITHIN SURROUNDING EXTERIOR WALLS (OR
EXTERIOR WALLS AND FIRE WALLS) EXCLUSIVE OF VENT SHAFTS AND COURTS. AREAS
OF THE BUILDING NOT PROVIDED WITH SURROUNDING WALLS SHALL BE INCLUDED IN
THE BUILDING AREA IF SUCH AREAS ARE INCLUDED WITHIN THE HORIZONTAL
PROJECTION OF THE ROOF OR FLOOR ABOVE.
TABULATION OF GROSS SQUARE FOOTAGE
FIRE PROTECTION
THE BUILDING IS NOT SPRINKLERED. THE FIRE DETECTION SYSTEM IS PROVIDED IN
ACCORDANCE WITH VCC REQUIREMENTS. THE WHOLE BUILDING HAS A FIRE ALARM
SYSTEM
FIRE RESISTANT RATING REQUIREMENTS FOR BUILDING ELEMENTS(TABLE 601)
BEARING WALLS: INTERIOR/EXTERIOR 0 HOUR
NONBEARING WALLS & PARTITIONS: 0 HOUR EXTERIOR/INTERIOR
COLUMNS: 0 HOUR
BEAMS: 0 HOUR
FLOOR CONSTRUCTION: 0 HOUR
ROOF CONSTRUCTION: 0 HOUR
EXITS AND EXIT PASSAGEWAY: 1 HOUR
VERTICAL EXIT ENCLOSURE: 1 HOUR
VERTICAL SHAFTS 1- 3 STORIES: 1 HOUR
ACCESSIBLE MEANS OF EGRESS:
1009.1 ACCESSIBLE MEANS OF EGRESS REQUIRED. ACCESSIBLE MEANS OF EGRESS SHALL
COMPLY WITH THIS SECTION. ACCESSIBLE SPACES SHALL BE PROVIDED WITH NOT LESS
THAN ONE ACCESSIBLE MEANS OF EGRESS. WHERE MORE THAN ONE MEANS OF EGRESS
ARE REQUIRED BY SECTION 1006.2 OR 1006.3 FROM ANY ACCESSIBLE SPACE, EACH
ACCESSIBLE PORTION OF THE SPACE SHALL BE SERVED BY NOT LESS THAN TWO
ACCESSIBLE MEANS OF EGRESS.
MEANS OF EGRESS STAIRWAYS:
1005.3.1 STAIRWAYS. THE CAPACITY, IN INCHES, OF MEANS OF EGRESS STAIRWAYS SHALL BE CALCULATED BY MULTIPLYING THE OCCUPANT LOAD SERVED BY SUCH STAIRWAYS BY A MEANS OF EGRESS CAPACITY FACTOR OF
0.3 INCH PER OCCUPANT. WHERE STAIRWAYS SERVE MORE THAN ONE STORY, ONLY THE OCCUPANT LOAD OF EACH STORY CONSIDERED INDIVIDUALLY SHALL BE USED IN CALCULATING THE REQUIRED CAPACITY OF THE
STAIRWAYS SERVING THAT STORY.
EXCEPTIONS: 1. FOR OTHER THAN GROUP H AND I-2 OCCUPANCIES, THE CAPACITY, IN INCHES, OF MEANS OF EGRESS STAIRWAYS SHALL BE CALCULATED BY MULTIPLYING THE OCCUPANT LOAD SERVED BY SUCH STAIRWAYS BY A MEANS OF EGRESS CAPACITY FACTOR OF 0.2 INCH PER OCCUPANT IN BUILDINGS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM INSTALLED IN ACCORDANCE WITH SECTION 903.3.1.1 OR 903.3.1.2 AND AN EMERGENCY VOICE/ALARM COMMUNICATION SYSTEM IN ACCORDANCE WITH SECTION 907.5.2.2.
1009.1 ACCESSIBLE MEANS OF EGRESS REQUIRED. ACCESSIBLE MEANS OF EGRESS SHALL COMPLY WITH THIS SECTION. ACCESSIBLE SPACES SHALL BE PROVIDED WITH NOT LESS THAN ONE ACCESSIBLE MEANS OF EGRESS.
WHERE MORE THAN ONE MEANS OF EGRESS ARE REQUIRED BY SECTION 1006.2 OR 1006.3 FROM ANY ACCESSIBLE SPACE, EACH ACCESSIBLE PORTION OF THE SPACE SHALL BE SERVED BY NOT LESS THAN TWO ACCESSIBLE
MEANS OF EGRESS.
1011.2 WIDTH AND CAPACITY. THE REQUIRED CAPACITY OF STAIRWAYS SHALL BE DETERMINED AS SPECIFIED IN
SECTION 1005.1, BUT THE MINIMUM WIDTH SHALL
BE NOT LESS THAN 44 INCHES.
EXIT WIDTH STAIRWAYS FLOOR 2
775 OCCUPANTS / 4 EXITS = 120 X 0.2 = 39" REQUIRED WIDTH - 48" ACTUAL WIDTH
AREA INCREASE
BUSINESS B AREA INCREASE
If = [F/P - 0.25]W/30
NOTE IN THE ABOVE COMPUTATION FOR W THAT, WHERE THE ACTUAL WIDTH
EXCEEDS 30 FEET (9144 MM), A VALUE OF 30 FEET (9144 MM) IS USED AS REQUIRED
BY SECTION 506.3.2.
.75= [F/P - 0.25]30/30
Aa = At + (NS x If) 86,250 = 69,000+ (23,000 x .75) = TOTAL ALLOWABLE AREA INCREASE
ACTUAL: 58,263 SF
EGRESS AND OCCUPANCY
1010.1.1 SIZE OF DOORS. THE REQUIRED CAPACITY OF EACH DOOR OPENING SHALL BE SUFFICIENT FOR THE
OCCUPANT LOAD THEREOF AND SHALL PROVIDE A MINIMUM CLEAR WIDTH OF 32 INCHES.
1006.2.1 EGRESS BASED ON OCCUPANT LOAD AND COMMON PATH OF EGRESS TRAVEL DISTANCE. TWO EXITS OR EXIT ACCESS DOORWAYS FROM ANY SPACE SHALL BE PROVIDED WHERE THE DESIGN OCCUPANT LOAD OR THE COMMON PATH OF EGRESS TRAVEL DISTANCE EXCEEDS THE VALUES LISTED IN TABLE 1006.2.1.
1004.3 POSTING OF OCCUPANT LOAD. EVERY ROOM OR SPACE THAT IS AN ASSEMBLY OCCUPANCY SHALL HAVE THE OCCUPANT LOAD OF THE ROOM OR SPACE POSTED IN A CONSPICUOUS PLACE, NEAR THE MAIN EXIT OR EXIT ACCESS DOORWAY FROM THE ROOM OR SPACE. POSTED SIGNS SHALL BE OF AN APPROVED LEGIBLE PERMANENT DESIGN AND SHALL BE MAINTAINED BY THE OWNER OR THE OWNER’S AUTHORIZED AGENT.
PER TABLE 1006.2.1 SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY THE MAXIMUM OCCUPANT LOAD OF SPACE WITH ONE EXIT IS 49 AND THE MAXIMUM COMMON PATH OF EGRESS TRAVEL DISTANCE WITH SPRINKLER
SYSTEM IS 100 FEET
EXIT ACCESS TRAVEL DISTANCE
-PER TABLE 1017.2 EXIT ACCESS TRAVEL DISTANCE OCCUPANCY GROUP B BUILDINGS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION 903.3.1.1 CAN HAVE AN EXIT ACCESS
TRAVEL DISTANCE OF 300 FEET.
-EXIT ACCESS TRAVEL DISTANCE WITH ONE EXIT (TABLE 1006.3.2(2)) B 75 FEET
EXIT ACCESS:
-EGRESS THROUGH INTERVENING SPACES (VCC 1016.2,2): EGRESS FROM A ROOM OR SPACE SHALL NOT PASS
THROUGH ADJOINING OR
INTERVENING ROOMS OR AREAS, EXCEPT WHERE SUCH ADJOINING ROOMS OR AREAS AND THE AREA SERVED
ARE ACCESSORY TO
ONE OR THE OTHER, ARE NOT A GROUP H OCCUPANCY AND PROVIDE A DISCERNIBLE PATH OF EGRESS TRAVEL
TO AN EXIT
EGRESS CORRIDORS
-MINIMUM CORRIDOR WIDTH (VCC TABLE 1020.2): 44” REQUIRED OTHER THAN LISTED BELOW 24” ACCESS TO
MECHANICAL, PLUMBING,
OR ELECTRICAL SYSTEMS OR EQUIPMENT 36” WITH REQUIRED OCCUPANCY CAPACITY LESS THAN 50 -1020.4 DEAD ENDS. WHERE MORE THAN ONE EXIT OR EXIT ACCESS DOORWAY IS REQUIRED, THE EXIT ACCESS
SHALL BE ARRANGED
SUCH THAT THERE ARE NO DEAD ENDS IN CORRIDORS MORE THAN 20 FEET IN LENGTH.
EXCEPTIONS: 2. IN OCCUPANCIES IN GROUPS B, E, F, I-1, M, R-1, R-2, R-4, S AND U, WHERE THE BUILDING IS
EQUIPPED
THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION 903.3.1.1, THE LENGTH
OF THE DEAD-END
CORRIDORS SHALL NOT EXCEED 50 FEET.
FIRE EXTINGUISHERS
-MAXIMUM FLOOR AREA FOR EXTINGUISHER (VCC TABLE 906.3 (1)) ORDINARY HAZARD OCCUPANCY:11,250 SF -MAXIMUM FLOOR TRAVEL DISTANCE FOR EXTINGUISHER (VCC TABLE 906.3 (1)) ORDINARY HAZARD OCCUPANCY:75 FEET
-FIRE EXTINGUISHER CLASSIFICATION (VCC 906.1, 1. AND VCC TABLE 906.3 (1)) 2-ABC
-FIRE EXTINGUISHERS FOR FLAMMABLE OR COMBUSTIBLE LIQUIDS WITH DEPTHS LESS THAN OR EQUAL TO 0.25 INCH:
TYPE OF HAZARD BASIC MINIMUM EXTINGUISHER RATING MAXIMUM DISTANCE OF TRAVEL TO EXTINGUISHERS
LOW 5-B 30 FEET
10-B 50 FEET
ORDINARY 10-B 30 FEET
20-B 50 FEET
EXTRA 40-B 30 FEET
80-B 50 FEET
STORAGE S-2 AREA INCREASE
If = [F/P - 0.25]W/30
NOTE IN THE ABOVE COMPUTATION FOR W THAT, WHERE THE ACTUAL WIDTH
EXCEEDS 30 FEET (9144 MM), A VALUE OF 30 FEET (9144 MM) IS USED AS REQUIRED
BY SECTION 506.3.2.
.75= [F/P - 0.25]30/30
Aa = At + (NS x If) 97,500 = 78,000 + (26,000 x .75) = TOTAL ALLOWABLE AREA INCREASE
ACTUAL: 20,182 SF
ASSEMBLY A-3 AREA INCREASE
If = [F/P - 0.25]W/30
NOTE IN THE ABOVE COMPUTATION FOR W THAT, WHERE THE ACTUAL WIDTH
EXCEEDS 30 FEET (9144 MM), A VALUE OF 30 FEET (9144 MM) IS USED AS REQUIRED
BY SECTION 506.3.2.
.75= [F/P - 0.25]30/30
Aa = At + (NS x If) 35,625 = 28,500+ (9,500 x .75) = TOTAL ALLOWABLE AREA INCREASE
ACTUAL: 4,290 SF
508.4.2 ALLOWABLE BUILDING AREA. IN EACH STORY, THE BUILD-ING
AREA SHALL BE SUCH THAT THE SUM OF THE RATIOS OF THE
ACTUAL BUILDING AREA OF EACH SEPARATED OCCUPANCY DIVIDED
BY THE ALLOWABLE BUILDING AREA OF EACH SEPARATED OCCU-PANCY
SHALL NOT EXCEED 1
ASSEMBLY A-3 AREA INCREASE
58,263/86250 + 20,182/97,500 +4,290 /35,625
.68 + .2 +.12 = 1
S-2
A-3
B
B
VIRGINIA BEACH, VIRGINIA 23462
4525 MAIN STREET, SUITE 1400
757·455·5800
1 2 3 4 5 6
A
B
C
D
E
SHEET
B
C
D
E
DESIGN:
DRAWN:
REVIEW:
REVISIONSDESIGNER
A
PROFESSIONAL SEAL
NOT F
OR C
ONSTRUCTIO
N
5032 ROUSE DRIVE, SUITE 200
VIRGINIA BEACH, VA 23462-3764
757.490.9264
CIVIL CONSULTANT
C U s e rs
\B G
U R
C Z
Y N
S K
I\ O n e D ri v e
C la rk N e x s e n \D o c u m e n ts
\1
P o rt s m o u th C o m p le x H
Q A b g u rc z y n s k i_
C la rk N e x s e n c o m
.r v t
/1
/2
:2
:1
P
M
BUILDING CODE SUMMARY
Designer
Author
Checker
CN 1020535% SUBMITTAL DOCUMENTS
JANUARY 16, 2024
PORTSMOUTH PUBLIC SAFETY COMPLEX
CITY OF PORTSMOUTH
3701 WILLETT DR
PORTSMOUTH, VA 23707
GI002H
FLOOR EXISTING (SQ FT) RENOVATION (SQ FT) NEW (SQ FT) SUB-TOTAL (SQ FT)
FIRST FLOOR 0 SF 0 SF 82735 SF 82,735 SF
SECOND FLOOR 0 SF 0 SF 64798 SF 64,798 SF
TOTAL 0 SF 0 SF 147533 SF 147,533 SF
NOT TO SCALE
FIRST FLOOR ROOM DIAGRAM
NOT TO SCALE
SECOND FLOOR ROOM DIAGRAM
UP
W D
PF
A CCES SORY
S TORAGE
A REAS,
MECHA NICAL
E QUIP ME NT
ROOM
A SSE MBLY
W ITHOUT
FIX ED
S EATS
UNCONCENTRATED
(TA BLES
AND
CHA IRS)
B USINESS
A REAS
E DUCA TIONAL
CLA SSROOM
AREA
E XERCISE
ROOMS
K ITCHENS,
COMMERCIAL
LOCKER
ROOMS
W AREHOUSES
5,857 SF
B
40 OCC
H1002
H1014
H1009
H1021
ST2
ELV 1
H1121
H1110
H1106
H1042
H1046
H1111
H1038
H1116
H1028
H1100
ELV 2
H1202
H1204
H1218
H1209
H1220
H1223
H1222
H1246 H1247
H1248
ELV 3
ST3
H1302H1301
H1300
H1304 H1303
H1305
H1306
H1040
H1041
H1250
H1104
H1022
H1010
H1207
H1211
H1112
H1018
H1039
H1043
H1241 H1214
H1215
H1212 H1213H1210
H1238
H1227
H1224
H1234
H1226
H1232
H1237H1236H1235
H1228 H1229 H1230
H1231
H1233
H1239
H1244 H1243 H1242
H1245
H1006
H1005
H1001
H1000
ST1
H1003
H1004
H1205
H1221
H1036
H1037
H1035
H1033
H1032
H1030
H1029
H1034
H1031
H1120
H1114
H1115
H1122
H1118
H1117
H1109
H1108
H1103
H1102
H1047
H1045
H1219
H1216 H1217
H1251
H1208
H1024
H1107
H1019
H1016
H1013
H1011A
H1026
H1025
H1027
H1119
H1017
H1015
H1012
H1023
H1101
H1200
1,595 SF
B-W
4 OCC
72 SF
B-AS
1 OCC
1,659 SF
B-AS
6 OCC
598 SF
B-E
30 OCC
519 SF
B-E
26 OCC
3,735 SF
A3
249 OCC
1,804 SF
A3
121 OCC
224 SF
B-A3
15 OCC
213 SF
B-A3
15 OCC
208 SF
B-A3
14 OCC
3,622 SF
B-EX
73 OCC
465 SF
B-AS
2 OCC
120 SF
B-AS
1 OCC
287 SF
B-AS
1 OCC
53 SF
B-AS
1 OCC
157 SF
B-AS
1 OCC
156 SF
B-AS
1 OCC
937 SF
B-AS
4 OCC
193 SF
B-AS
1 OCC
336 SF
B-A3
23 OCC
703 SF
B-A3
47 OCC
198 SF
B-A3
14 OCC
385 SF
B-AS
2 OCC
179 SF
B-AS
1 OCC
179 SF
B-AS
1 OCC
137 SF
B-AS
1 OCC
404 SF
B-AS
2 OCC
268 SF
B-AS
1 OCC
112 SF
B-AS
1 OCC
669 SF
B-AS
3 OCC 20,182 SF
S2-W
41 OCC
661 SF
S2-B
5 OCC
855 SF
S2-B
6 OCC
1,169 SF
B-E
59 OCC
260 SF
B-AU
18 OCC
532 SF
B-AU
36 OCC
719 SF
B-K
4 OCC
1,666 SF
B-L
34 OCC
4,290 SF
A3
366 OCC
60 SF
B-AS
1 OCC
H1017A
440137
22057
220183
220183
220 37
220 37
220 1
220 1
220 2
833 SF
B-AS
3 OCC
75 SF
B-AS
1 OCC
51 SF
B-AS
1 OCC
729 SF
B-W
2 OCC
H1008
428 SF
B-AS
2 OCC
22,934 SF
B
145 OCC
22057
578 SF
B-AS
2 OCC
4,290 SF
A3
366 OCC
R-1
75 OCC
RESIDENTIAL
200 GSF / 1 PERSON
(VUSBC TABLE 1004.1.1)
ACTUAL OCCUPANCY
BASED ON COT SLEEPING
CONFIGURATION : 75 COTS
1. COORDINATE ALL FIRE EXTINGUISHERS LOCATIONS SHOWN ON PLANS W/
LOCAL FIRE OFFICIAL'S REQUIREMENTS.
2. PROVIDE & INSTALL ALL BLOCKING IN WALLS AS REQUIRED FOR
MOUNTING FIRE EXTINGUISHERS.
3. COORDINATE INSTALLATION REQUIREMENTS OF EXIT SIGNS, ALL
ASSOCIATED HARDWARE, JUNCTION BOXES, WIRING & REQUIRED EXIT
DEVICES W/ ELECTRICAL DRAWINGS & LOCAL INSPECTOR.
4. RATED WALLS AND PARTITIONS REQUIRED TO HAVE PROTECTED
OPENINGS SHALL BE PERMANENTLY STENCILED EVERY 10'-0" ABOVE THE
CEILING OR CONCEALED SPACE.
EXAMPLE:
• 1-HOUR RATED BARRIER - PROTECT ALL OPENINGS
EGRESS TRAVEL PATH
FIRE EXTINGUISHER CABINET
FIRE EXTINGUISHER BRACKET
FEC
SPACE AREA
SPACE NAME
OCCUPANT LOAD (PEOPLE)
PATH ID
FEB
SPACE NAME
9,876 SF 385 OCC
MAXIMUM OCCUPANT EGRESS LOAD
ACTUAL OCCUPANT EGRESS LOAD 220 120
USE GROUP LEGEND - AREAS BASED ON VUSBC TABLE 1004.5
B BUSINESS
B BUSINESS 150 GROSS
B-AS ACCESSORY STORAGE AREAS, MECHANICAL
EQUIPEMENT ROOM 300 GROSS
B-AU ASSEMBLY WITHOUT FIXED SEATS 15 NET
B-E CLASSROOM 20 NET
B-EX EXERCISE ROOMS 50 GROSS
B-L LOCKER ROOMS 50 GROSS
B-K KITCHENS, COMMERCIAL 200 GROSS
S-2 LOW HAZARD STORAGE
S2-W WAREHOUSE 500 GROSS
S2-B BUSINESS AREA 150 GROSS
A-3 ASSEMBLY
A-3 ASSEMBLY
SCALE: 1/16" = 1'-0"
FIRST FLOOR LIFE SAFETY PLAN GRAPHIC SCALE(S)
RATED PARTITION
LEGEND 1
1/16" = 1' - 0" 0 5' 10' 20' 30' 60'
VIRGINIA BEACH, VIRGINIA 23462
4525 MAIN STREET, SUITE 1400
757·455·5800
1 2 3 4 5 6
A
B
C
D
E
SHEET
B
C
D
E
DESIGN:
DRAWN:
REVIEW:
REVISIONSDESIGNER
A
PROFESSIONAL SEAL
NOT F
OR C
ONSTRUCTIO
N
5032 ROUSE DRIVE, SUITE 200
VIRGINIA BEACH, VA 23462-3764
757.490.9264
CIVIL CONSULTANT
C U s e rs
\B G
U R
C Z
Y N
S K
I\ O n e D ri v e
C la rk N e x s e n \D o c u m e n ts
\1
P o rt s m o u th C o m p le x H
Q A b g u rc z y n s k i_
C la rk N e x s e n c o m
.r v t
/1
/2
:2
:4
P
M
HQ FIRST FLOOR LIFE SAFETY PLAN
Designer
Author
Checker
CN 1020535% SUBMITTAL DOCUMENTS
JANUARY 16, 2024
PORTSMOUTH PUBLIC SAFETY COMPLEX
CITY OF PORTSMOUTH
3701 WILLETT DR
PORTSMOUTH, VA 23707
GI101H
LIFE SAFETY - OCCUPANT CALCULATION - FIRST FLOOR
LEVEL PATTERN FUNCTION OF SPACE
SF PER
PERSON OCCUPANCY SF TYPE AREA
*NUMBER OF
OCCUPANTS
FIRST FLOOR ACCESSORY STORAGE AREAS, MECHANICAL EQUIPMENT ROOM 300 GROSS 8,458 SF 41
FIRST FLOOR ASSEMBLY WITHOUT FIXED SEATS - UNCONCENTRATED (TABLES AND CHAIRS) 15 NET 12,502 SF 918
FIRST FLOOR BUSINESS AREAS 150 GROSS 30,307 SF 196
FIRST FLOOR EDUCATIONAL - CLASSROOM AREA 20 NET 2,286 SF 115
FIRST FLOOR EXERCISE ROOMS 50 GROSS 3,622 SF 73
FIRST FLOOR KITCHENS, COMMERCIAL 200 GROSS 719 SF 4
FIRST FLOOR LOCKER ROOMS 50 GROSS 1,666 SF 34
FIRST FLOOR WAREHOUSES 500 GROSS 22,505 SF 47
FIRST FLOOR TOTALS: 82,065 SF 1428
* NUMBER OF OCCUPANTS IS AN AGGREGATE AND IS A RESULT OF ROUNDING UP INDIVIDUAL AREAS
(SB)
SMOKE BARRIER (SB), SMOKE PARTITION
(SP), OR PARTITION CAPABLE OF
RESISTING THE PASSAGE OF SMOKE (S)
TWO HOUR FIRE RATING
ONE HOUR FIRE RATING
GENERAL NOTES
2-HOUR MIXED USE SEPERATION
FIRST FLOOR ROOM SCHEDULE
Number Name
H1002 PROPERTY & EVIDENCE
H1014 VEHICLE EXAMINATION
H1009 SHIPPING & RECEIVING
H1021 SALLY PORT
ST2 STAIR
ELV 1 ELEV.
H1121 DEFENSE TACTICS TRAINING CLASSROOM
H1110 VEHICLE SERVICES
H1106 FORCE SIMULATOR
H1042 RESIDENTIAL SIMULATOR
H1046 MEN'S TOILET
H1111 COMPUTER CLASSROOM
H1038 COMPUTER CLASSROOM
H1116 POLICE TRAINING OFFICE
H1028 FIRE TRAINING OFFICE
H1100 RECORDS
ELV 2 ELEV.
H1202 PUBLIC LOBBY
H1204 MULTIPURPOSE ROOM
H1218 MENS
H1209 PROFESSIONAL STANDARDS
H1220 BREIFING ROOM
H1223 MED. CONF.
H1222 MED. CONF.
H1246 EM. ELEC.
H1247 MAIN ELEC.
H1248 MECHANICAL
ELV 3 ELEV.
ST3 STAIR
H1302 MENS LOCKER ROOM
H1301 WOMENS LOCKER ROOM
H1300 COMMERCIAL KITCHEN & CAFETERIA
H1304 TELECOM
H1303 ELECTRICAL
H1305 GYM
H1306 BASKETBALL COURT
H1040 ELEC.
H1041 TELECOM
H1250 PREFUNCTION SPACE
H1310 OUTDOOR COVERED SEATING
H1104 CORRIDOR
H1022 PRIVATE CORRIDOR
H1010 PRIVATE CORRIDOR
H1207 FAMILY WAITING
H1211 VISITOR WAITING
H1112 ACADEMY CLASSROOM
H1018 FORENSICS LAB
H1039 BREAK
H1043 LRG. CONF.
H1241 MAG
H1214 RECORD STORAGE
H1215 LT OFFICE
H1212 INTERVIEW
H1213 POLYGRAPH
FIRST FLOOR ROOM SCHEDULE
Number Name
H1001 VESTIBULE
H1000 PUBLIC LOBBY
ST1 STAIR
H1003 GUN CAGE
H1004 DRUG CAGE
H1205 STORAGE
H1221 STO
H1036 EMS VIEWING
H1037 EMS TRAINING
H1035 SML. CONF.
H1033 STORAGE
H1032 LT OFFICE
H1030 CLINICAL
H1029 CAPTAIN
H1034 LT
H1031 STORAGE
H1120 STORAGE
H1114 STORAGE
H1115 ARMOR OFFICE
H1122 CADET BREAK ROOM
H1118 LT
H1117 SRGT
FIRST FLOOR ROOM SCHEDULE
Number Name
H1210 INTERVIEW
H1238 HEARING
H1227 PUBLIC TOILET
H1224 STORAGE
H1234 PRIVATE BATHROOM
H1226 BREAK ROOM
H1232 WAITING AREA
H1237 HEARING
H1236 HEARING
H1235 HEARING
H1228 VISITOR
H1229 VISITOR
H1230 VISITOR
H1231 VISITOR
H1233 VISITOR
H1239 HEARING
H1244 REGIONAL SUPERVISOR
H1243 CHIEF MAGISTRATE
H1242 CONFERENCE
H1245 PROBABLE CAUSE
H1006 OFFICER LOBBY
H1005 VESTIBULE
FIRST FLOOR ROOM SCHEDULE
Number Name
H1109 STORAGE
H1108 BREAK ROOM
H1103 RECORDS
H1102 PATROL GEAR ISSUE
H1047 VCIN TERMINAL
H1045 WOMEN'S TOILET
H1219 WOMENS
H1216 MENS
H1217 WOMENS
H1251 BREAK
H1208 JAN
H1024 VESTIBULE
H1107 CORRIDOR
H1019 FILE AND SUPPLY STORAGE
H1016 AFIS STORAGE
H1013 FORENSICS
H1011A QUARTERMASTER
H1026 STORAGE
H1025 ANIMAL SERVICES
H1027 VESTIBULE
H1119 STORAGE
H1017 FORENSIC TECH
FIRST FLOOR ROOM SCHEDULE
Number Name
H1015 EQUIPMENT STORAGE
H1012 VESTIBULE
H1023 CORRIDOR
H1101 POLY
H1200 ENTRANCE VESTIBULE
H1007 JAN
H1020 JAN
H1017A OFFICE
H1017B CORRIDOR
H1206 AV
H1201 STORAGE
H1240 MAGISTRATE
H1225 COAT
H1113 CORRIDOR
H1044 CORRIDOR
H1203 SRGT
H1008 FIRE PUMP
H1307 ELECTRICAL
H1309 TELECOM
H1308 TELECOM
H1120A STORAGE
H1105 VESTIBULE
H1312 CORRIDOR
H1311 CORRIDOR
H1011B CHANGING ROOM
H1011C CHANGING ROOM
DN
UP
45,948 SF
B
317 OCC
H2103
H2249
H2105
ELV 2
H2019
H2011
H2017H2003
H2008
H2125
ST1
ELV 4
H2010
H2023
ST2
H2119
H2054
H2108
H2022
H2021
H2129
H2218
H2214
H2217
H2311
ELV 3
ST3
H2238
H2314 H2312
H2235
H2236
H2323
H2028
H2000
H2106
H2234
H2233
H2315
H2102
H2104
H2209
H2206
H2131
H2208
H2207
H2130
H2203
H2221
H2226
H2224H2223
H2200H2201
H2222
H2202
H2215
H2211
H2205
H2020
H2013
H2014
H2012
H2016
H2015
H2018
H2056
H2057
H2065
H2055
H2101
H2100
H2247
H2306
H2246
H2303 H2301
H2248
H2310 H2308 H2307
H2305
H2135
H2136
H2213
H2210
H2212 H2216
H2313
H2229
H2006
H2007
H2044
H2004
H2005
H2024
H2026
H2025
H2237
H2317
H2324
H2325
H2320
H2053
H2318
H2319
H2321 H2322
H2316
H2001
H2219H2126
H2111
H2112
H2113
H2116
H2117
H2120
H2121
H2115
H2128
H2124
H2052
H2122
H2123
H2133
H2114B
H2118
H2309
H2302
H2304
H2232
H2228
H2225
H2227
H2241
H2244
H2242
H2245
H2240
H2243
H2220
H2009
H2127
H2051
H2034
H2045
H2043
H2033
H2042
H2027
H2030
H2029
H2031
H2032
H2050
H2049
H2048
H2047
H2046
H2035
H2036
H2037
H2038
H2039
H2041
H2040
299 SF
B-A3
20 OCC
303 SF
B-A3
21 OCC
252 SF
B-A3
17 OCC
150 SF
B-A3
11 OCC
296 SF
B-A3
20 OCC
326 SF
B-A3
22 OCC
621 SF
B-A3
42 OCC
342 SF
B-A3
23 OCC
392 SF
B-A3
27 OCC
182 SF
B-A3
13 OCC
209 SF
B-A3
14 OCC
416 SF
B-A3
28 OCC
411 SF
B-E
28 OCC
145 SF
B-A3
10 OCC
111 SF
B-A3
8 OCC
156 SF
B-AS
11 OCC
162 SF
B-AS
1 OCC
172 SF
B-AS
1 OCC
149 SF
B-A3
10 OCC
112 SF
B-AS
1 OCC
245 SF
B-AS
1 OCC
175 SF
B-AS
1 OCC
175 SF
B-AS
1 OCC
168 SF
B-AS
1 OCC
99 SF
B-AS
1 OCC
A CCES SORY STORAGE A RE AS , MECHA NICAL E QUIP MENT ROOM
A SS EMBLY WITHOUT FIXE D SE ATS - UNCONCENTRATED (TA BLES A ND CHA IRS)
B USINES S AREAS
1,071 SF
B-AS
4 OCC
151 SF
B-AS
1 OCC
150 SF
B-AS
1 OCC
114 SF
B-AS
1 OCC
109 SF
B-AS
1 OCC
185 SF
B-AS
1 OCC
164 SF
B-AS
1 OCC
192 SF
B-AS
1 OCC
200 SF
B-AS
1 OCC
88 SF
B-AS
1 OCC
42 SF
B-AS
1 OCC
220194
2 HOUR APPLIED
FIREPROOFING AT
COLUMNS, BEAMS, GIRDERS,
BRACED FRAMES, AND
UNDERSIDE OF FLOOR SLAB
ABOVE
1,566 SF
Area
1. COORDINATE ALL FIRE EXTINGUISHERS LOCATIONS SHOWN ON PLANS W/
LOCAL FIRE OFFICIAL'S REQUIREMENTS.
2. PROVIDE & INSTALL ALL BLOCKING IN WALLS AS REQUIRED FOR
MOUNTING FIRE EXTINGUISHERS.
3. COORDINATE INSTALLATION REQUIREMENTS OF EXIT SIGNS, ALL
ASSOCIATED HARDWARE, JUNCTION BOXES, WIRING & REQUIRED EXIT
DEVICES W/ ELECTRICAL DRAWINGS & LOCAL INSPECTOR.
4. RATED WALLS AND PARTITIONS REQUIRED TO HAVE PROTECTED
OPENINGS SHALL BE PERMANENTLY STENCILED EVERY 10'-0" ABOVE THE
CEILING OR CONCEALED SPACE.
EXAMPLE:
• 1-HOUR RATED BARRIER - PROTECT ALL OPENINGS
EGRESS TRAVEL PATH
FIRE EXTINGUISHER CABINET
FIRE EXTINGUISHER BRACKET
FEC
SPACE AREA
SPACE NAME
OCCUPANT LOAD (PEOPLE)
PATH ID
FEB
SPACE NAME
9,876 SF 385 OCC
MAXIMUM OCCUPANT EGRESS LOAD
ACTUAL OCCUPANT EGRESS LOAD 220 120
USE GROUP LEGEND - AREAS BASED ON VUSBC TABLE 1004.5
B BUSINESS
B BUSINESS 150 GROSS
B-AS ACCESSORY STORAGE AREAS, MECHANICAL
EQUIPEMENT ROOM 300 GROSS
B-AU ASSEMBLY WITHOUT FIXED SEATS 15 NET
B-E CLASSROOM 20 NET
B-EX EXERCISE ROOMS 50 GROSS
B-L LOCKER ROOMS 50 GROSS
B-K KITCHENS, COMMERCIAL 200 GROSS
S-2 LOW HAZARD STORAGE
S2-W WAREHOUSE 500 GROSS
S2-B BUSINESS AREA 150 GROSS
A-3 ASSEMBLY
A-3 ASSEMBLY
SCALE: 1/16" = 1'-0"
SECOND FLOOR LIFE SAFETY PLAN
VIRGINIA BEACH, VIRGINIA 23462
4525 MAIN STREET, SUITE 1400
757·455·5800
1 2 3 4 5 6
A
B
C
D
E
SHEET
B
C
D
E
DESIGN:
DRAWN:
REVIEW:
REVISIONSDESIGNER
A
PROFESSIONAL SEAL
NOT F
OR C
ONSTRUCTIO
N
5032 ROUSE DRIVE, SUITE 200
VIRGINIA BEACH, VA 23462-3764
757.490.9264
CIVIL CONSULTANT
C U s e rs
\B G
U R
C Z
Y N
S K
I\ O n e D ri v e
C la rk N e x s e n \D o c u m e n ts
\1
P o rt s m o u th C o m p le x H
Q A b g u rc z y n s k i_
C la rk N e x s e n c o m
.r v t
/1
/2
:2
:2
P
M
HQ SECOND FLOOR LIFE SAFETY PLAN
Designer
Author
Checker
CN 1020535% SUBMITTAL DOCUMENTS
JANUARY 16, 2024
PORTSMOUTH PUBLIC SAFETY COMPLEX
CITY OF PORTSMOUTH
3701 WILLETT DR
PORTSMOUTH, VA 23707
GI102H
* NUMBER OF OCCUPANTS IS AN AGGREGATE AND IS A RESULT OF ROUNDING UP INDIVIDUAL AREAS
LIFE SAFETY - OCCUPANT CALCULATION - SECOND FLOOR
LEVEL PATTERN OCCUPANCY
SF PER
PERSON OCCUPANCY SF TYPE AREA
*NUMBER OF
OCCUPANTS
SECOND FLOOR ACCESSORY STORAGE AREAS, MECHANICAL EQUIPMENT ROOM 300 GROSS 5,342 SF 22
SECOND FLOOR ASSEMBLY WITHOUT FIXED SEATS - UNCONCENTRATED (TABLES AND CHAIRS) 15 NET 6,355 SF 436
SECOND FLOOR BUSINESS AREAS 150 GROSS 45,948 SF 317
FIRST FLOOR TOTALS: 57,645 SF 775
SECOND FLOOR ROOM SCHEDULE
Number Name
H2103 CHIEF OF POLICE
H2249 ADMIN SERVICES
H2105 SM. CONF.
ELV 2 ELEV.
H2019 DISTRICT LTS
H2011 SPECIAL OPS
H2017 GANG SUPPRESSION
H2003 BREAK ROOM
H2008 MD. CONF.
H2125 STREET CRIMES
ST1 STAIR
ELV 4 ELEV.
H2010 CRIMINAL INVESTIGATIONS
H2023 NARCOTICS
ST2 STAIR
H2119 ROLL CALL
H2054 MEN'S TOILET
H2108 CRIME ANALYSIS
H2022 TELECOM
H2021 ELEC.
H2129 WELLNESS ROOM
H2218 MENS RESTROOM
H2214 STORAGE
H2217 FINANCIAL SUPPORT
H2311 FIRE MARSHALL
ELV 3 ELEV.
ST3 STAIR
H2238 I.T.
H2314 TELECOM
H2312 ELEC.
H2235 WELLNESS ROOM
H2236 MOTHERS ROOM
H2323 EOC
H2028 PRIVATE INTERVIEW CORE
H2000 MD. CONF.
H2106 SOFT INTERVIEW
H2234 REAL TIME CRIME
H2233 PRINT/COPY
H2315 BREAKOUT
H2102 POLICE CHIEF
H2104 EXECUTIVE CONF.
H2209 HR STORAGE
H2206 SUPERVISOR
H2131 POLYGRAPH
H2208 MEDICAL DIRECTOR
H2207 CLINCAL CARE
H2130 EMS
H2203 CAPTAIN
H2221 CHIEF
H2226 MED. CONF.
H2224 DEPUTY CHIEF
H2223 DEPUTY CHIEF
H2200 BATTALION CHIEF
H2201 BATTALION CHEIF
H2222 ADMIN SERVICES CORDINATOR
H2202 EMS MANAGER
H2215 SUPPLIES
H2211 HR
H2205 FISCAL MANAGER
H2020 STORAGE
H2013 STORAGE
H2014 LT
H2012 STORAGE
H2016 GSU STORAGE
SECOND FLOOR ROOM SCHEDULE
Number Name
H2015 INTERVIEW
H2018 LOBBY
H2056 PIO
H2057 PIO
H2065 ASSISTANT CHIEF
H2055 ASSISTANT CHIEF
H2101 ASSISTANT CHIEF
H2100 COPY/PRINT
H2247 LT
H2306 CAPT
H2246 EVIDENCE STORAGE
H2303 STORAGE
H2301 FIRE FIGHTER
H2248 DECON
H2310 FIRE FIGHTER
H2308 FIRE FIGHTER
H2307 FIRE FIGHTER
H2305 INTERVIEW ROOM
H2135 DIRECTOR
H2136 SUPERVISOR
H2213 MEETING
H2210 COPY/ PRINT
SECOND FLOOR ROOM SCHEDULE
Number Name
H2212 LOBBY
H2216 STORAGE
H2313 MEETING
H2229 BREAK ROOM
H2006 STORAGE
H2007 STORAGE
H2044 AV MONITORING
H2004 CAPTAIN
H2005 LT
H2024 STORAGE
H2026 LT
H2025 SURVEILLANCE EQUP.
H2237 I.T.
H2317 BREAKOUT
H2324 MANAGER
H2325 CAPTAIN
H2320 PLANNER
H2053 WOMEN'S TOILET
H2318 JOINT OPERATIONS
H2319 REPONSES AND RECOVERY
H2321 PIO
H2322 PLANNING
SECOND FLOOR ROOM SCHEDULE
Number Name
H2316 PLOTTER
H2001 LRG. CONF.
H2219 WOMENS RESTROOM
H2126 STORAGE
H2111 BREATHALYZER
H2112 FUGITIVE APPREHENSION
H2113 STORAGE
H2116 PLATOON 1
H2117 PLATOON 2
H2120 PLATOON 3
H2121 PLATOON 4
H2115 REPORT
H2128 MOTHERS
H2124 CAPT
H2052 SECURITY
H2122 LT
H2123 CAPT
H2133 ADMIN SERVICES
H2114B CORRIDOR
H2118 STORAGE
H2309 FIRE FIGHTER
H2302 FIRE FIGHTER
SECOND FLOOR ROOM SCHEDULE
Number Name
H2304 INTERVIEW ROOM
H2232 CLASSROOM
H2228 QUIET
H2225 MEETING
H2227 LOCKERS
H2241 MANAGER
H2244 QUALITY ASSURANCE
H2242 TRAINING
H2245 IT
H2240 DISPATCH
H2243 ADMIN
H2220 FIRE ADMIN
H2009 PRINT COPY
H2127 BREAK
H2051 INTERVIEW
H2034 INTERVIEW
H2045 INTERVIEW
H2043 INTERVIEW
H2033 AV MONITORING
H2042 AV MONITORING
H2027 VESTIBULE
H2030 HOLDING
SECOND FLOOR ROOM SCHEDULE
Number Name
H2029 HOLDING
H2031 HOLDING
H2032 HOLDING
H2050 HOLDING
H2049 HOLDING
H2048 HOLDING
H2047 HOLDING
H2046 HOLDING
H2035 HOLDING
H2036 HOLDING
H2037 HOLDING
H2038 HOLDING
H2039 HOLDING
H2041 UNISEX
H2040 UNISEX
H2239 OFFICE
H2107 SOFT INTERVIEW
H2109 CRIME ANALYSIS SVR
H2110 PLOTTER WORK AREA
H2230 BREAK
H2229 QUIET
H2231 STORAGE
H2114C ELEC
H2114A CORRIDOR
GRAPHIC SCALE(S)
RATED PARTITION
LIFE SAFETY LEGEND
1/16" = 1' - 0" 0 5' 10' 20' 30' 60'
(SB)
SMOKE BARRIER (SB), SMOKE PARTITION
(SP), OR PARTITION CAPABLE OF
RESISTING THE PASSAGE OF SMOKE (S)
TWO HOUR FIRE RATING
ONE HOUR FIRE RATING
GENERAL NOTES
V e n t H o o d
C R
CR
C R
CR
CRCR
C R
C R
C R
CR
C R
C R
CR
C R
CR
C R
C R
C R
C R
C R
CR
CR
C R
CR
C R
C R
C R
CR
C R
C R
C R
CR
CR
C R
CR
CR
C R
C R
C R
CR
C R
C R
C R
CR
C
RC
R
DN
UP
12002100
VIRGINIA BEACH, VIRGINIA 23462
4525 MAIN STREET, SUITE 1400
757·455·5800
1 2 3 4 5 6
A
B
C
D
E
SHEET
B
C
D
E
DESIGN:
DRAWN:
REVIEW:
REVISIONSDESIGNER
A
PROFESSIONAL SEAL
NOT F
OR C
ONSTRUCTIO
N
5032 ROUSE DRIVE, SUITE 200
VIRGINIA BEACH, VA 23462-3764
757.490.9264
CIVIL CONSULTANT
C U s e rs
\B G
U R
C Z
Y N
S K
I\ O n e D ri v e
C la rk N e x s e n \D o c u m e n ts
\1
P o rt s m o u th C o m p le x H
Q A b g u rc z y n s k i_
C la rk N e x s e n c o m
.r v t
/1
/2
:2
:4
P
M
ROOM NUMBER DIAGRAMS
Designer
Author
Checker
CN 1020535% SUBMITTAL DOCUMENTS
JANUARY 16, 2024
PORTSMOUTH PUBLIC SAFETY COMPLEX
CITY OF PORTSMOUTH
3701 WILLETT DR
PORTSMOUTH, VA 23707
GI110H
NOT TO SCALE
FIRST FLOOR ROOM DIAGRAM
NOT TO SCALE
SECOND FLOOR ROOM DIAGRAM
1. THE BUILDING HAS TWO LEVELS, EACH WITH DISTINCT
AREAS. ON THE FIRST LEVEL, THE ROOM NUMBERS ARE
ORGANIZED INTO SECTIONS: 1000'S, 1100'S, 1200'S, AND
1300'S. ON THE SECOND LEVEL, THE ROOM NUMBERS ARE
ORGANIZED INTO SECTIONS: 2000'S, 2100'S, 2200'S, AND
2300'S.
2. THIS SYSTEMATIC ARRANGEMENT PROVIDES CLARITY IN
NAVIGATING THE BUILDING AND LOCATING SPECIFIC
ROOMS WITHIN EACH DESIGNATED AREA DURING
CONSTRUCTION. FINAL BUILDING NUMBERING FOR
SIGNAGE SUBJECT TO CHANGE.
GENERAL NOTES
EGRESS TRAVEL PATH
FIRE EXTINGUISHER CABINET
FIRE EXTINGUISHER BRACKET
FEC
SPACE AREA
SPACE NAME
OCCUPANT LOAD (PEOPLE)
PATH ID
FEB
SPACE NAME
9,876 SF 385 OCC
MAXIMUM OCCUPANT EGRESS LOAD
ACTUAL OCCUPANT EGRESS LOAD 220 120
6,779 SF
S-1
14 OCC
A CCES SORY
S TORAGE
A REAS,
MECHA NICAL
E QUIP ME NT
ROOM
B USINESS
A REAS
W AREHOUSES
6,429 SF
S-1
13 OCC
378 SF
S-1
1 OCC 808 SF
S-1
2 OCC
167 SF
S-1
1 OCC
29 SF
S-1
1 OCC
194 SF
S-1
1 OCC
194 SF
S-1
1 OCC
200 SF
S-1
1 OCC
194 SF
S-1
1 OCC
661 SF
S-1
2 OCC901 SF
S-1
2 OCC
431 SF
S-1
1 OCC40 SF
AS
1 OCC
74 SF
AS
1 OCC
74 SF
AS
1 OCC
521 SF
S-1
2 OCC
QUARTERMASTER
STORAGE
127W
CIVIL
DISTURBANCE
121W
PROPERTY &
EVIDENCE
STORAGE
126W
DISTRICT
LIEUTENANTS
STORAGE
118W
RESTROOM
124W
CORRIDOR
122W
TELECOM
119W
FIRE MARSHALL
STORAGE
114W
EMS TRAINING
STORAGE
116W
EMS DIVISION
STORAGE
115W
LOGISTICS
STORAGE
117W
VEHICLE
STORAGE
130W
VEHICLE
STORAGE
100W
VEHICLE
STORAGE
135W
VEHICLE
STORAGE
136W
SPECIAL OPS
STORAGE
128W
VEHICLE
STORAGE
105W
VEHICLE
STORAGE
104W
VEHICLE
STORAGE
103W
VEHICLE
STORAGE
101W
VEHICLE
STORAGE
129W
VEHICLE
STORAGE
133W
VEHICLE
STORAGE
132W
VEHICLE
STORAGE
134W
I.T. MONOPOLE
125W
ELEC
120W
VEHICLE
STORAGE
131W
VEHICLE
STORAGE
137W
LOGISTICS
OFFICES
106W
RESTROOM
123WCAPTAIN
109W
LT
108W
LT
107W
TURN OUT GEAR
113W
MAINTENCE
AREA
110W
SUPPLY
STORAGE
111W
CRAWL GEAR
STORAGE
112W
819 SF
B
6 OCC
393 SF
S-1
1 OCC
141' - 9"
TD-1
128' - 3"
TD-2
93' - 9"
TD-4
116' - 8"
TD-3
1,395 SF
B
10 OCC
JAN
137X
220 5 2205
220 21
2,123 SF
S-1
5 OCC
1. COORDINATE ALL FIRE EXTINGUISHERS LOCATIONS SHOWN ON PLANS
W/ LOCAL FIRE OFFICIAL'S REQUIREMENTS.
2. PROVIDE & INSTALL ALL BLOCKING IN WALLS AS REQUIRED FOR
MOUNTING FIRE EXTINGUISHERS.
3. COORDINATE INSTALLATION REQUIREMENTS OF EXIT SIGNS, ALL
ASSOCIATED HARDWARE, JUNCTION BOXES, WIRING & REQUIRED EXIT
DEVICES W/ ELECTRICAL DRAWINGS & LOCAL INSPECTOR.
4. RATED WALLS AND PARTITIONS REQUIRED TO HAVE PROTECTED
OPENINGS SHALL BE PERMANENTLY STENCILED EVERY 10'-0" ABOVE
THE CEILING OR CONCEALED SPACE.
EXAMPLE:
• 1-HOUR RATED BARRIER - PROTECT ALL OPENINGS
BUILDING CODE SUMMARY
APPLICABLE CODES
BUILDING PURPOSE/OCCUPANCY:
CONSTRUCTION TYPE:
USE GROUP:
ALLOWABLE BUILDING HEIGHT:
-2018 VIRGINIA CONSTRUCTION CODE
-2018 VIRGINIA STATEWIDE FIRE PREVENTION CODE (VSFPC)
-2018 VIRGINIA PLUMBING CODE
-2018 VIRGINIA MECHANICAL CODE
-2018 VIRGINIA ENERGY CONSERVATION CODE - IECC 2018
-2018 VIRGINIA FUEL GAS CODE (VFGC)
-2017 NFPA 70 NATIONAL ELECTRICAL CODE
-2016 NFPA 13 STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS
-2016 NFPA 72 NATIONAL FIRE ALARM CODE
-2010 NFPA 110 STANDARD FOR EMERGENCY AND STANDBY POWER SYSTEMS
-2010 UL294 ACCESS CONTROLS SYSTEM UNITS
-2010 ADA STANDARDS FOR ACCESSIBLE DESIGN - DEPARTMENT OF JUSTICE (ADASAD)
-2009 ICC A117.1 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES
-WAREHOUSE STORAGE SPACE FOR FIRE AND POLICE DEPARTMENTS.
-TYPE IIB (VCC TABLE 504.3 AND TABLE 601)
STORAGE GROUP S-1; WAREHOUSE
TABLE 504.3 ALLOWABLE BUILDING HEIGHT IN FEET ABOVE GRADE PLANE
TYPE IIB SPRINKLERED:
ALLOWABLE: 75'-0"
ACTUAL: 47'-6"
TABLE 504.4 ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLANE
TYPE IIB SPRINKLERED
ALLOWABLE: 4 STORIES
ACTUAL: 1 STORY
ALLOWABLE BUILDING AREA
TABLE 506.2 ALLOWABLE AREA
TYPE IIB NON SPRINKLERED:
ALLOWABLE: 69,000 SF
ACTUAL: 27,044
TABULATION OF BUILDING AREA
AREA, BUILDING. THE AREA INCLUDED WITHIN SURROUNDING EXTERIOR WALLS (OR EXTERIOR
WALLS AND FIRE WALLS) EXCLUSIVE OF VENT SHAFTS AND COURTS. AREAS OF THE BUILDING NOT PROVIDED WITH SURROUNDING WALLS SHALL BE INCLUDED IN THE BUILDING AREA IF SUCH AREAS
ARE INCLUDED WITHIN THE HORIZONTAL PROJECTION OF THE ROOF OR FLOOR ABOVE.
TABULATION OF GROSS SQUARE FOOTAGE
FIRE PROTECTION
THE BUILDING IS NOT SPRINKLERED. THE FIRE DETECTION SYSTEM IS PROVIDED IN ACCORDANCE
WITH VCC REQUIREMENTS. THE WHOLE BUILDING HAS A FIRE ALARM SYSTEM
FIRE RESISTANT RATING REQUIREMENTS
FOR BUILDING ELEMENTS(TABLE 601)
BEARING WALLS: INTERIOR/EXTERIOR 0 HOUR
NONBEARING WALLS & PARTITIONS: 0 HOUR EXTERIOR/INTERIOR
COLUMNS: 0 HOUR
BEAMS: 0 HOUR
FLOOR CONSTRUCTION: 0 HOUR
ROOF CONSTRUCTION: 0 HOUR
EXITS AND EXIT PASSAGEWAY: 1 HOUR
VERTICAL EXIT ENCLOSURE: 1 HOUR
VERTICAL SHAFTS 1- 3 STORIES: 1 HOUR
ACCESSIBLE MEANS OF EGRESS:
1009.1 ACCESSIBLE MEANS OF EGRESS REQUIRED. ACCESSIBLE MEANS OF EGRESS SHALL COMPLY WITH THIS SECTION. ACCESSIBLE SPACES SHALL BE PROVIDED WITH NOT LESS THAN ONE ACCESSIBLE MEANS OF EGRESS. WHERE MORE THAN ONE MEANS OF EGRESS ARE REQUIRED BY SECTION 1006.2 OR 1006.3 FROM ANY ACCESSIBLE SPACE, EACH ACCESSIBLE PORTION OF THE SPACE SHALL BE
SERVED BY NOT LESS THAN TWO ACCESSIBLE MEANS OF EGRESS.
EGRESS AND OCCUPANCY
1010.1.1 SIZE OF DOORS. THE REQUIRED CAPACITY OF EACH DOOR OPENING SHALL BE SUFFICIENT FOR THE
OCCUPANT LOAD THEREOF AND SHALL PROVIDE A MINIMUM CLEAR WIDTH OF 32 INCHES.
1006.2.1 EGRESS BASED ON OCCUPANT LOAD AND COMMON PATH OF EGRESS TRAVEL DISTANCE. TWO EXITS OR EXIT ACCESS DOORWAYS FROM ANY SPACE SHALL BE PROVIDED WHERE THE DESIGN OCCUPANT LOAD OR THE COMMON PATH OF EGRESS TRAVEL DISTANCE EXCEEDS THE VALUES LISTED IN TABLE 1006.2.1.
1004.3 POSTING OF OCCUPANT LOAD. EVERY ROOM OR SPACE THAT IS AN ASSEMBLY OCCUPANCY SHALL HAVE THE OCCUPANT LOAD OF THE ROOM OR SPACE POSTED IN A CONSPICUOUS PLACE, NEAR THE MAIN EXIT OR EXIT ACCESS DOORWAY FROM THE ROOM OR SPACE. POSTED SIGNS SHALL BE OF AN APPROVED LEGIBLE PERMANENT DESIGN AND SHALL BE MAINTAINED BY THE OWNER OR THE OWNER’S AUTHORIZED AGENT.
PER TABLE 1006.2.1 SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY THE MAXIMUM OCCUPANT LOAD OF SPACE WITH ONE EXIT IS 49 AND THE MAXIMUM COMMON PATH OF EGRESS TRAVEL DISTANCE WITH SPRINKLER
SYSTEM IS 100 FEET
EXIT ACCESS TRAVEL DISTANCE
-PER TABLE 1017.2 EXIT ACCESS TRAVEL DISTANCE OCCUPANCY GROUP B BUILDINGS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION 903.3.1.1 CAN HAVE AN EXIT ACCESS
TRAVEL DISTANCE OF 300 FEET.
-EXIT ACCESS TRAVEL DISTANCE WITH ONE EXIT (TABLE 1006.3.2(2)) B 75 FEET
EXIT ACCESS:
-EGRESS THROUGH INTERVENING SPACES (VCC 1016.2,2): EGRESS FROM A ROOM OR SPACE SHALL NOT PASS
THROUGH ADJOINING OR
INTERVENING ROOMS OR AREAS, EXCEPT WHERE SUCH ADJOINING ROOMS OR AREAS AND THE AREA SERVED ARE
ACCESSORY TO
ONE OR THE OTHER, ARE NOT A GROUP H OCCUPANCY AND PROVIDE A DISCERNIBLE PATH OF EGRESS TRAVEL TO
AN EXIT
EGRESS CORRIDORS
-MINIMUM CORRIDOR WIDTH (VCC TABLE 1020.2): 44” REQUIRED OTHER THAN LISTED BELOW 24” ACCESS TO MECHANICAL, PLUMBING, OR ELECTRICAL SYSTEMS OR EQUIPMENT 36” WITH REQUIRED OCCUPANCY CAPACITY
LESS THAN 50
-1020.4 DEAD ENDS. WHERE MORE THAN ONE EXIT OR EXIT ACCESS DOORWAY IS REQUIRED, THE EXIT ACCESS SHALL BE ARRANGED SUCH THAT THERE ARE NO DEAD ENDS IN CORRIDORS MORE THAN 20 FEET IN LENGTH.
EXCEPTIONS: 2. IN OCCUPANCIES IN GROUPS B, E, F, I-1, M, R-1, R-2, R-4, S AND U, WHERE THE BUILDING IS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION 903.3.1.1, THE
LENGTH OF THE DEAD-END CORRIDORS SHALL NOT EXCEED 50 FEET.
FIRE EXTINGUISHERS
TYPE OF HAZARD BASIC MINIMUM EXTINGUISHER RATING MAXIMUM DISTANCE OF TRAVEL TO EXTINGUISHERS
LOW 5-B 30 FEET
10-B 50 FEET
ORDINARY 10-B 30 FEET
20-B 50 FEET
EXTRA 40-B 30 FEET
80-B 50 FEET
-MAXIMUM FLOOR AREA FOR EXTINGUISHER (VCC TABLE 906.3 (1)) ORDINARY HAZARD OCCUPANCY:11,250 SF -MAXIMUM FLOOR TRAVEL DISTANCE FOR EXTINGUISHER (VCC TABLE 906.3 (1))…