This file includes construction drawings and specifications for upgrades to a porch and other areas of a building for a veterans program, along with the corresponding federal contract opportunity. The drawings show plans for replacing windows, adding French doors, creating a new doorway opening, relocating washers and dryers' connections, and building a new wrap around porch. Specifications include requirements for materials, construction, demolition, supervision, and completion of work. The related federal contract opportunity is seeking a contractor to perform this work for the PACER program building located at the South Texas Veterans Health Care System campus in San Antonio, Texas. The solicitation is being issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 17.
View the file
Other files for this federal contract opportunity
Show all 23
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
W as he r
W as he r
D ry er D ry er
UP
DN
A101
A102
A102
A102
A102
11' - 5"11' - 5" 11' - 5" 11' - 5" 11' - 5"
11' - 5"
8'
3"
11' - 5"
1' - 4"
5'
0"
1'
4"
1' - 4"
0' - 8"
0' - 8"
A102
A102
A102
A103
A103
Level 1 0' - 0"
Level 2 14' - 0"
A102
1' - 4"
11' - 5"11' - 5"11' - 5"11' - 5"11' - 5"11' - 5" 13
3' - 4" 3' - 4"
3' - 4" 3' - 4"
A103
Level 1 0' - 0"
Level 2 14' - 0"
0'
4"
8'
0"
COLUMN: HSS 6X6X1/4
WELDED BASE PLATE
1' - 4"
Level 1 0' - 0"
Level 2 14' - 0"
A102
3' - 4" 3' - 4" 3' - 4" 3' - 4" 3' - 4"3' - 4" 3' - 4" 3' - 4" 3' - 4" 3' - 4" 3' - 4"
A104
A104
Level 2 14' - 0"
3' - 4" 3' - 4"
3' - 4" 3' - 4"
3' - 4"
Level 1 0' - 0"
A102
0'
8"
3' - 10"
Level 1 0' - 0"
Level 2 14' - 0"
3' - 4" 3' - 4"
3' - 4" 3' - 4"
3' - 4"
A102
A102
A102
A102
A102
A103
Level 1 0' - 0"
A102 www.autodesk.com/revit
Scale
Date
Drawn By
Checked By
Project Number
Consultant Address Address Address Phone
Consultant Address Address Address Phone
Consultant Address Address Address Phone
Consultant Address Address Address Phone
Consultant Address Address Address Phone
As indicated
3/
/2
:0 0:
P
M
A102
Porch
Install Upgrades for PACER Program @
PTRP
Checker Author
Issue Date Project Number
No. Description Date
1/8" = 1'-0"5 New Piers
1/8" = 1'-0"1 Section 11
16" DIA. 3000 PSI PIER
w/ (4) - #6 VERTICAL BARS
& #3 TIES @ 8" PLUS
EXTRA 2 WINDS AT TOP
12' DEPTH
1/4" = 1'-0"2 Structure Framing
4" 3000 PSI CONCRETE FLAT WORK
w/ #4 @ 12"
ON MIN. 6" COMPACTED SELECT FILL
USE MINIMUM:
3/4 IN. ANCHOR ROD DIAMETER
1-5/16 IN. HOLE DIAMETER
2 IN. WASHER DIMENSION
1/4 IN. WASHER THICKNESS
(4) - 12 IN ANCHOR ROD LENGTH
USE BRICK VEREER:
ACME BRICK BLEND 121, MODULARSIZE, HERITAGE TEXTURE
MORTAR TYPE S MIX DESIGN:
1 BAG PORTLAND TYPE 1 ASTM C150
1/2 BAG LIME TYPE S ASTM C207
7 - 5 GALLON BUCKETS A-! MASONRY
1/2 QUART ADMIXTURE WATER REPELLANT
16 OUNCES COLOR PIGMENTATION
12 to 16 GALLONS WATER
1/8" = 1'-0"3 Section 4
1/4" = 1'-0"4 Roof Framing
6" x 6" PRE-FINISHED METAL GUTTER
USE 6"X6" PRE-FINISHED METAL DOWNSPOUT
USE HSS 4X4X1/4 FOR ROOF FRAMING
KEYNOTES
1. USE BERRIDGE DOUBLE-LOCK ZEE-LOCK PANEL 24 GAUGE STEEL
2. PRIME & PAINT FRAMING
3.. CAP STONE ALL BRICK LOCATIONS
1.
2.3.
1/8" = 1'-0"6 Exterior Stairs
1/8" = 1'-0"7 Section 3 1/8" = 1'-0"8 Handrail