Project Statement 171-26617.pdf

PDF 145 KB Posted

Attached to
171/26617. JGH; Hall of Justice - Structural Study
Solicitation number
RFP 171 270000000297 1
Issued by
Michigan

About this file

This is a Project Statement issued by the Michigan Department of Technology, Management and Budget (DTMB), Design and Construction Division, for a structural evaluation and study of the Hall of Justice located at 925 W Ottawa Street in Lansing, Michigan. The project seeks professional services to conduct a comprehensive evaluation of multiple building failures and provide repair recommendations for the Hall of Justice, which houses the Michigan Supreme Court and was constructed between 1999-2002. The identified issues include a sinkhole on the north side of the building, water and concrete problems in two of three underground parking garages, failure of entry doors and cladding, heaving exterior pavers and ramps with water infiltration, and cracking and failing exterior masonry. The scope of work is a Phase 100 study project that will require evaluation of the existing site and structure, preparation of a comprehensive study with repair recommendations and cost estimation, and may include survey work, geotechnical evaluation, and structural and civil evaluation. The mandatory walk-through inspection is scheduled for Wednesday, December 2, 2026, at 1:00 p.m. in the main lobby, and proposals must be submitted via SIGMA VSS by Thursday, December 17, 2026, at 2:00 p.m. Eastern Time. Questions must be emailed to the Project Director, Jared Gavin-Helfrich, by Wednesday, December 9, 2026, at 2:00 p.m. Eastern Time. Design work is scheduled to take place in 2027.

Proposing firms must submit their total cost for all phases as the bid amount and may combine technical and cost proposals into one attachment not to exceed 25 megabytes. All proposals must be uploaded to SIGMA VSS; emailed submissions are only acceptable on a case-by-case basis with Design and Construction Division approval and must be received prior to the 2:00 p.m. deadline. The project must comply with all applicable federal, state, and local codes, standards, and regulations administered by agencies including the EPA, OSHA, DOT, DHHS, EGLE, DNR, and MIOSHA. The applicable NIGP codes are 90607, 90610, 90633, 90638, and 91066. No set-asides, incumbent information, funding sources, or specific contract amounts are identified in this document.

View the file

Other files

File Type Posted
RFP Billable Rate 171-26617.pdf PDF
SAMPLE Billable Rate Contract (Rev 04-25).pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DTMB-0427 (R 04/26)

PROJECT STATEMENT

STATE OF MICHIGAN

DEPARTMENT OF TECHNOLOGY, MANAGEMENT AND BUDGET

State Facilities Administration Design and Construction Division

3111 West St. Joseph Street Lansing, Michigan 48909

FILE NUMBER

171/26617.JGH

PROPOSAL DUE DATE

Thursday December 17, 2026, at 2:00 p.m., EASTERN

CLIENT AGENCY

Department of Technology, Management, & Budget

PROJECT NAME AND LOCATION

Hall of Justice – Structural Study

PROJECT ADDRESS (if applicable) 925 W Ottawa Street Lansing, MI 48909

CLIENT AGENCY CONTACT

Bill Harris

TELEPHONE NUMBER

(517) 896-7614

DTMB - DCD PROJECT DIRECTOR

Jared Gavin-Helfrich

TELEPHONE NUMBER

(517) 290-1516

WALK-THROUGH INSPECTION DATE, TIME, AND LOCATION:

Wednesday December 2, 2026, 1:00 pm

Pre-proposal attendees should meet in the main lobby.

MANDATORY (Check box if Mandatory)

NOTE: An individual is only permitted to represent one firm at a mandatory walk-through.

PROJECT DESCRIPTION/SERVICES REQUESTED:

The Hall of Justice is experiencing multiple internal and external failures and needs an evaluation/study to determine the cause(s) of these failures and recommendations for repairs. The Hall of Justice houses the Michigan Supreme Court as well as extensive legal staff and was constructed between 1999-2002.

The observed (2025-2026) issues include:

• A sinkhole has formed at the north side of the building, approximately 6’ in diameter and 2-3’ deep.

• Two of three underground parking garages are experiencing both water and concrete problems, including sand appearing at the drain of the lower level, slow drainage, cracking and spalling concrete within the garage, and possible structural shifting.

• The entry doors and surrounding cladding are experiencing failure and need to be replaced.

• Exterior pavers and ramps are heaving (design documentation was previously completed for mitigation of these issues but not implemented) and experiencing water infiltration.

• The exterior masonry cladding of the building has multiple issues including cracking and failing stone.

Proposing firms will be responsible for a full evaluation of the existing site and structure and preparing a study that outlines these issues and includes recommendations for repairs as well as cost estimation. This may need to include survey work, geotechnical evaluation, structural and civil evaluation.

This will be a Phase 100 study project.

Please NOTE:

• Proposal responses MUST be uploaded to SIGMA VSS.

https://sigma.michigan.gov/webapp/PRDVSS1X1/Advantage4

• Please enter the total cost for all phases as the bid amount.

• Firms are encouraged to combine their technical and cost proposals into one (1) attachment for proposal submission.

• Please remember that attachments can be no larger than 25mb.

• Do not wait until just before the 2:00 p.m. solicitation deadline to submit your proposal response.

SIGMA VSS will not allow a proposal to be submitted after 2:00 p.m., even if a portion of the proposal response has been uploaded.

• If you experience issues or have questions regarding your electronic submission, you must contact the SIGMA Help Desk for assistance prior to the 2:00 p.m., solicitation deadline. You may contact the SIGMA Help Desk by telephone at 517.284.0540 or toll-free at 888.734.9749. You may also email the SIGMA Help Desk at sigma-procurement-helpdesk@michigan.gov

• Please email the Design and Construction Contract Specialists if you are having SIGMA VSS issues. Please include your SIGMA ticket number and any supporting documentation (i.e., screenshots) to Anne Watros (WatrosA@michigan.gov) and Don Klein (KleinD4@michigan.gov).

• You may be asked by our contract specialists to email your proposal. Emailed submissions will require DCD approval and will be handled on a case-by-case basis.

• Approved emailed submissions MUST be received prior to 2:00 p.m. deadline to be considered responsive and responsible.

• Responses should not be emailed to the Project Director.

NIGP CODES

90607, 90610, 90633, 90638, 91066

DESIRED SCHEDULE OF WORK

Design to take place in 2027

ACCEPTING RFP QUESTIONS UNTIL:

Please do not submit online questions via SIGMA VSS. ALL questions should be emailed to Jared Gavin- Helfrich at gavinhelfrichj@michigan.gov address no later than 2:00 p.m., Eastern on Wednesday December 9th, 2026.

REFERENCE STANDARDS: This project will comply with all codes, standards, regulations, and workers' safety rules that are administered by federal agencies (EPA, OSHA, and DOT), state agencies (DHHS, EGLE, DNR, and MIOSHA), and any other local regulations and standards that may apply.

This form is required to be a part of the professional service contract. (Authority: 1984 PA 431) Attachment(s) https://sigma.michigan.gov/webapp/PRDVSS1X1/Advantage4 mailto:sigma-procurement-helpdesk@michigan.gov mailto:WatrosA@michigan.gov mailto:KleinD4@michigan.gov mailto:gavinhelfrichj@michigan.gov

File details come from the government source that posted it. Updated .