Project Drawings.pdf
PDF 1 MB Posted
- Attached to
- Ottumwa Community Schools Tennis Courts
- Solicitation number
- 02305957
- Issued by
- Wapello County, Iowa
About this file
This document contains the project drawings and specifications for the Ottumwa Community Schools Tennis Courts project, which is being solicited by the Ottumwa Community School District located in Ottumwa, Iowa. Sealed bids for this project will be received on November 7, 2023 at 2:00 PM local time. A pre-bid conference will be held on November 2, 2023 at 1:00 PM at the Ottumwa District Office. Bidders are strongly encouraged to attend the pre-bid conference and perform a site visit prior to submitting bids. The project involves the construction of new tennis courts using a post-tensioned concrete slab on grade. The drawings provide details on the slab design, reinforcement, post-tensioning, and other construction requirements. A bid alternate is included to construct the courts using a reinforced concrete slab on grade instead of post-tensioning.
The bid proposals will be lump sum, and bid security in the form of a bid bond, certified check, or cash is required. The school district reserves the right to reject any or all bids. Contractors may obtain electronic bid documents at no cost from the district or state of Iowa website. Hard copies of the plans and specifications will be available at the contractor's expense. The contract award date is not specified in the documents.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Ottumwa Courts - Addendum No. 1.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CLIENT CONTACT INFORMATION:
DAVID HARPER
CHIEF OPERATIONS OFFICER
PHONE: (641) 684-6597 EXT. #66112
OLSSON CONTACT INFORMATION:
CARY SCHROEDER, SE (NE)
TECHNICAL LEADER
PHONE: (402) 970-2316
drawn by:
checked by:
approved by:
QA/QC by:
project no.:
drawing no.:
date
SHEET
R E
V
IS
IO
N
S
R E
V
N O
D
A T
E R
E V
IS
IO
N D
E S
C R
IP
T
IO
N
:5 :0
P M
C R e vi t L o c a l F il e s S O tt u m w a
T e n n is
C o u rt s C e n tr a l_ c a ry s c h ro e d e r.
rv t
XXX
XXX
XXX
10/17/2023
O T
T U
M W
A
IA
O T
T U
M W
A C
O M
M U
N
IT
Y S
C H
O O
L S
T E
N N
IS
C
O U
R T
S
C O
V E
R S
H E
E T
G000
OTTUMWA COMMUNITY SCHOOLS
TENNIS COURTS
Ottumwa, IA 52501
SHEET INDEX
SHEET SHEET NAME
REVISION
DATE REV
G000 COVER SHEET
S001 POST-TENSION SLAB NOTES AND SPECIAL INSPECTION SCHEDULE
S100 POST-TENSION SLAB PLAN - OVERALL
S101 POST-TENSION SLAB PLAN
S200 DETAILS - POST-TENSION
P S tr ee t S ui te
Li nc ol n, N E
T E
L
2.
4.
F
A X
.4
.5 w w w
.o ls so n.
co m
E ng in ee rin g
N eb ra sk a
C O
A
C A
-0
INSTRUCTIONS TO BIDDERS:
1. SEALED BIDS WILL BE RECIEVED ON TUESDAY, NOVEMBER 7, 2023 AT 2:00 PM PREVIALING TIME FOR THE
TENNIS COURT PROJECT BY;
THE BOARD OF EDUCATION: OTTUMWA COMMUNITY SCHOOL DISTRICT
1112 N. VAN BUREN
OTTUMWA, IA 52501
2. LUMP SUM BID PROPOSALS WILL BE RECIEVED FOR THIS PROJECT AT THE SCHEDULED TIME OF
RECIEPT OF BIDS ABOVE AND WILL BE PUBLICLY OPENED AT THAT TIME.
3. A PRE-BID CONFERENCE WILL BE HELD ON THURSDAY NOVEMBER 2, 2023 AT 1:00 PM (CST) AT THE OTTUMWA DISTRICT OFFICE; 1112 N. VAN BUREN, OTTUMWA, IA 52501. ALL BIDDERS ARE STRONGLY ENCOURAGED TO ATTEND AND SIGN IN AT THE MEETING WHICH WILL ALSO BE ATTENDED BY THE
OWNER.
4. ALL BIDDERS ARE STRONGLY ENCOURAGED TO PERFORM A SITE VISIT PRIOR TO SUBMITTING BIDS.
5. BID SECURITY IN THE FOR OF A BID BOND, CERTIFIED CHECK OR CASH IN AN AMOUNT EQUAL TO FIVE PERCENT OF THE BASE BID AMOUNT SHALL BE SUBMITTED WITH THE BID. SHOULD A BID BOND BE SUBMITTED, THE BID BOND SHALL BE PAYABLE TO THE BOARD OF EDUCATION - OTTUMWA COMMUNITY
SCHOOL DISTRICT.
6. BIDS SHALL BE SUBMITTED ON OR BEFORE THE SPECIFIED CLOSING TIME IN AN OPAQUE SEALED
ENVELOPE ADDRESSED TO:
OTTUMWA COMMUNITY SCHOOL DISTRICT
ATTN: MR. MIKE McGREGORY, SUPERINTENDENT
1112 N. VAN BUREN
OTTUMWA, IA 52501
7. THE BOARD OF EDUCATION RESERVES THE RIGHT TO REJECT ANY BID OR ALL BIDS OR PART THEREOF, OR WAIVE ANY IRREGULARITIES OR INFORMALITIES, AND TO MAKE THE AWARD IN THE BEST INTEREST
OF THE DISTRICT.
8. CONTRACTOR MAY OBTAIN ELECTRONIC BID DOCUMENTS AT NO COST IN PDF FORM THROUGH DAVID
HARPER AT DAVID.HARPER@OTTUMWASCHOOLS.COM OR THROUGH CARY SCHROEDER AT
CSCHROEDER@OLSSON.COM OR VIA THE STATE OF IOWA AT https://bidopportunities.iowa.gov/
9. CONTRACTORS SHALL BE RESPONSIBLE FOR ANY HARD COPY SETS OF PLANS OR SPECIFICATIONS AT
THE CONTRACTORS COST.
MY LICENSE RENEWAL DATE IS DECEMBER 31, 2019.
PAGES OR SHEETS COVERED BY THIS SEAL:
I HEREBY CERTIFY THAT THIS ENGINEERING DOCUMENT WAS PREPARED BY ME OR
UNDER MY DIRECT PERSONAL SUPERVISION AND THAT I AM A DULY REGISTERED
PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF IOWA
SIGNATURE
MY LICENSE RENEWAL DATE IS DECEMBER 31, 2023.
NAME: ADAM R. CHRISTENSEN
S001, S100, S101, S200
10/24/2023 drawn by:
checked by:
approved by:
QA/QC by:
project no.:
drawing no.:
date
SHEET
R E
V
IS
IO
N
S
R E
V
N O
D
A T
E R
E V
IS
IO
N D
E S
C R
IP
T
IO
N
:5 :0
P M
C R e vi t L o c a l F il e s S O tt u m w a
T e n n is
C o u rt s C e n tr a l_ c a ry s c h ro e d e r.
rv t
PKM
CWS
CWS
023-05957
10/17/2023
O T
T U
M W
A
IA
O T
T U
M W
A C
O M
M U
N
IT
Y S
C H
O O
L S
T E
N N
IS
C
O U
R T
S
P O
S T
-T E
N S
IO
N
S L A
B N
O T
E S
A N
D S
P E
C
IA
L
IN
S P
E C
T
IO
N S
C H
E D
U L E
S001
AE AIR ENTRAINING
AFF ABOVE FINISHED
FLOOR
AHU AIR HANDLING UNIT
ALT ALTERNATE
APPROX APPROXIMATE(LY)
ARCH ARCHITECT(URAL)
B/ BOTTOM OF
BLDG BUILDING
BM BEAM
BOT BOTTOM
BRG BEARING
C COMPRESSION
CA CAISSON
CIP CAST-IN-PLACE
CJ CONTROL JOINT
CL CENTERLINE
CLR CLEAR
CMU CONCRETE
MASONRY UNIT
COL COLUMN
CONC CONCRETE
CONN CONNECTION
CONST CONSTRUCTION
CONT CONTINUE(D)(OUS)
DBA DEFORMED BAR
ANCHOR
DBL DOUBLE
DET DETAIL
DIA DIAMETER
DIM DIMENSION(S)
DL DEAD LOAD
DP DRILLED PIER
DWG DRAWING
EA EACH
ECC ECCENTRICITY
EF EACH FACE
EJ EXPANSION JOINT
ELEV ELEVATION
EOR ENGINEER OF
RECORD
EQ EQUAL
EQUIP EQUIPMENT
ES EACH SIDE
EW EACH WAY
EWEF EACH WAY EACH
FACE
FF FINISHED FLOOR
FND FOUNDATION
FT FEET (FOOT)
FTG FOOTING
GA GAUGE
GALV GALVANIZED
GB GRADE BEAM
GL GLUE LAMINATE
TIMBER
HORZ HORIZONTAL
HS HEADED STUD
ID INSIDE DIAMETER
K KIP (1000 POUNDS)
STRUCTURAL ABBREVIATIONS
w w w .o ls so n.
co m
S ou th
7t h S tr ee t, S ui te
O m ah a, N E
T
E L
2.
1.
F A
X
.3
.5
E ng in ee rin g
N eb ra sk a
C O
A
C A
-0
KLF KIPS PER LINEAR
FOOT
LB, # POUNDS
LH LEFT HAND
LL LIVE LOAD
LLH LONG LEG
HORIZONTAL
LLV LONG LEG VERTICAL
LVL LAMINATED VENEER
LUMBER
MAX MAXIMUM
MECH MECHANICAL
MEP MECHANICAL,
ELECTRICAL,
PLUMBING
MFR MANUFACTURER
MIN MINIMUM
MISC MICELLANEOUS
NA NOT APPLICABLE
NO, # NUMBER
NTS NOT TO SCALE
OC ON CENTER
OCEW ON CENTER EACH
WAY
OD OUTSIDE DIAMETER
OH OPPOSITE HAND
PEMB PRE-ENGINEERED
METAL BUILDING
PJF PREMOLDED JOINT
FILLER
PL PLATE
PLF POUNDS PER LINEAR
FOOT
PSF POUND PER SQUARE
FOOT
PSI POUND PER SQUARE
INCH
PT POST TENSION(ED)
QTY QUANTITY
R RADIUS
REINF REINFORCE(D)
REV REVISED/REVISION
RH RIGHT HAND
RO ROUGH OPENING
RTU ROOF TOP UNIT
SF SQUARE FOOT
SIM SIMILAR
SPEC SPECIFICATION
SS STAINLESS STEEL
STD STANDARD
T TENSION
T&B TOP AND BOTTOM
T&G TONGUE AND GROVE
T/ TOP OF
TBD TO BE DETERMINED
TYP TYPICAL
UON UNLESS OTHERWISE
NOTED
V SHEAR
VERT VERTICAL
VIF VERIFY IN FIELD
W/ WITH
W/O WITHOUT
WG WORKABLE GAGE
WP WORKING POINT
WWR WELDED WIRE
REINFORCEMENT
CONCRETE & REINFORCING STEEL
VERIFY CORRECT MATERIAL USED,
INCLUDING THE USE OF A706 IN
WELDED SPLICES, IF ANY
OBSERVE & VERIFY PLACEMENT OF
EMBEDDED BOLTS & RODS PRIOR TO
CONCRETE PLACEMENT
SAMPLE CONCRETE SPECIMENS FOR
STRENGTH TESTS TO BE PERFORMED IN
LAB. A MINIMUM OF FIVE (5) CYLINDERS
SHALL BE MADE. TEST TWO AT 7 DAYS
AND TWO AT 28 DAYS. THE 5TH
CYLINDER SHALL BE HELD IN RESERVE
PERFORM CONCRETE STRENGTH
TESTING
MAINTAIN A SPREADSHEET SHOWING
DATE, SEQUENTIAL ORDER OF
STRENGTH TEST RESULTS, AND
INDICATE RUNNING AVERAGE
INSPECT CONCRETE AND SHOTCRETE
PLACEMENT FOR PROPER APPLICATION
TECHNIQUES
VERIFY THAT THE NECESSARY DESIGN
STRENGTH HAS BEEN REACHED PRIOR
TO THE REMOVAL OF FORMS
MEASURE FLOOR FLATNESS AND
LEVELNESS AS DIRECTED
AWS: D1.4
IBC: 1908.10
ASTM: C172, C31
ACI 318: 26.4,
26.12
ACI 318 PAR. 6.2
IBC: 1908.6,
1908.7, 1908.8
ACI 318: 26.5
ADDITIONAL CYLINDERS SHALL BE
MADE AS NEEDED FOR EARLY FORM
REMOVAL. NOTE: TWO 6X12 OR 4X8
CYLINDERS ARE REQUIRED FOR AN
ACCEPTABLE TEST.
INSPECT CONCRETE FORMWORK FOR
SHAPE, LOCATION, AND DIMENSIONS
OF THE CONCRETE MEMBER BEING
FORMED
VERIFY PLANT IS PCI
CERTIFIED
VERIFY FABRICATION/ QUALITY CONTROL
PROCEDURES FOR PRECAST CONCRETE
MANUFACTURER
GENERAL
CONDUCT WEEKLY VISUAL
OBSERVATIONS OF THE STRUCTURAL
SYSTEMS FOR GENERAL CONFORMANCE
TO THE CONSTRUCTION DOCUMENTS AND
PREPARE WEEKLY REPORTS OF
OBSERVATIONS DESCRIBING WORK
PROGRESS AND NON-CONFORMING ITEMS
INSPECTION ITEM REQUIRED
FREQUENCY
CONTINUOUS PERIODIC
REMARKSCODE
REFERENCE
IBC SCHEDULE OF SPECIAL INSPECTION SERVICES
OBSERVE PROOF ROLLING OF
SUBGRADE PRIOR TO FILL
PLACEMENT
EARTHWORK
TESTING AND EVALUATION OF IN-
PLACE DENSITY OF COMPACTED
FILL AS WORK PROGRESSES
VERIFY EXCAVATIONS ARE
EXTENDED TO PROPER DEPTH
AND HAVE REACHED PROPER
MATERIAL
PERFORM CLASSIFICATION AND
TESTING OF COMPACTED FILL
MATERIALS
ALL FOOTING AND PILE CAP
EXCAVATIONS SHALL BE OBSERVED
AND APPROVED PRIOR TO
CONCRETE PLACEMENT
TEST EACH SOURCE
ONE DENSITY TEST FOR EACH
LIFT, DAYS OPERATION, OR 5000
SQ. FT. OF FILL AREA
INSPECT VAPOR RETARDER FOR
CONFORMANCE WITH MANUFACTURERS
WRITTEN INSTALLATION INSTRUCTIONS
VERIFY MATERIAL BELOW SHALLOW
FOUNDATIONS ARE ADEQUATE TO
ACHIEVE THE DESIGN BEARING
CAPACITY
VERIFY USE OF PROPER MATERIALS,
DENSITIES AND LIFT THICKNESS DURING
PLACEMENT AND COMPACTION OF
COMPACTED FILL
INSPECTION ITEM REQUIRED
FREQUENCY
CONTINUOUS PERIODIC
REMARKSCODE
REFERENCE
IBC SCHEDULE OF SPECIAL INSPECTION SERVICES
INSPECT REINFORCEMENT, INCLUDING
PRESTRESSING TENDONS, AND VERIFY
PLACEMENT PRIOR TO CLOSING OF
FORMS AND ARRIVAL OF CONCRETE TO
THE JOB-SITE
IBC: 1908.4
ACI 318: CH. 20,
25.2, 25.3, 26.6.1-26.6.3
REINFORCING BAR WELDING:
a. VERIFY WELDABILITY OF
REINFORCING BARS
OTHER THAN ASTM A706
b. INSPECT SINGLE-PASS
FILLET WELDS, MAXIMUM
5/16"
c. INSPECT ALL OTHER
WELDS
AWS D1.4
ACI 318: 26.6.4
INSPECT ANCHORS CAST IN CONCRETE ACI 318:
17.8.2
INSPECT ANCHORS POST-INSTALLED IN
HARDENED CONCRETE MEMBERS:
a. ADHESIVE ANCHORS
INSTALLED IN
HORIZONTALLY UP
UPWARDLY INCLINED
ORIENTATIONS TO RESIST
SUSTAINED TENSION
LOADS
b. MECHANICAL ANCHORS
AND ADHESIVE ANCHORS
NOT DEFINED ABOVE
ACI 318:
17.8.2.4
ACI 318:
17.8.2
SPECIFIC REQUIREMENTS FOR
SPECIAL INSPECTION SHALL BE
INCLUDED IN THE RESEARCH
REPORT FOR THE ANCHOR ISSUED
BY AN APPROVED SOURCE IN
ACCORDANCE WITH 17.8.2 IN ACI 318,
OR OTHER QUALIFICATION
PROCEDURES. WHERE SPECIFIC
REQUIREMENTS ARE NOT PROVIDED,
SPECIAL INSPECTION
REQUIREMENTS SHALL BE
SPECIFIED BY THE REGISTERED
DESIGN PROFESSIONAL AND SHALL
BE APPROVED BY THE BUILDING
OFFICIAL PRIOR TO
COMMENCEMENT OF THE WORK
VERIFY USE OF REQUIRED MIX DESIGN IBC: 1904.1,
1904.2, 1908.2, 1908.3
ACI 318: CH. 19,
26.4.3, 26.4.4
PRIOR TO CONCRETE PLACEMENT,
FABRICATE SPECIMENS FOR STRENGTH
TESTS, PERFORM SLUMP AND AIR
CONTENT TESTS, AND DETERMINE THE
TEMPERATURE OF THE CONCRETE
OBTAIN ONE COMPOSITE SAMPLE
FOR EACH 100 CUBIC YARDS OR
FRACTION THEREOF OF EACH
CONCRETE MIX PLACED EACH DAY.
WHEN FREQUENCY OF TESTING WILL
PROVIDE FEWER THAN FIVE
COMPRESSIVE STRENGTH TESTS
FOR EACH CONCRETE MIX, TESTING
SHALL BE CONDUCTED FROM AT
LEAST FIVE RANDOMLY SELECTED
BATCHES OR FROM EACH BATCH IF
FEWER THAN FIVE ARE USED.
VERIFY MAINTENANCE OF SPECIFIED
CURING TEMPERATURE AND TECHNIQUES
IBC: 1908.9
ACI 318:
26.5.3-26.5.5
INSPECT PRESTRESSED CONCRETE FOR:
a. APPLICATION OF
PRESTRESSING FORCES
b. GROUTING OF BONDED
PRESTRESSING TENDONS
ACI 318: 2610
INSPECT ERECTION OF PRECAST
CONCRETE MEMBERS AND CONNECTIONS
ACI 318: CH. 26.8
VERIFY IN-SITU CONCRETE STRENGTH,
PRIOR TO STRESSING OF TENDONS IN
POST-TENSIONED CONCRETE AND PRIOR
TO REMOVAL OF SHORES AND FORMS
FROM BEAMS AND STRUCTURAL SLABS
ACI 318:
CH. 26.11.2
ACI 318:
26.11.1.2(b)
GENERAL STRUCTURAL NOTES:
FOUNDATIONS:
1. THE GEOTECHNICAL ENGINEER SHALL BE RETAINED FOR TESTING AND SPECIAL INSPECTIONS
DURING ALL EARTHWORK AND FOUNDATION CONSTRUCTION PHASES TO VERIFY THAT THE
RECOMMENDATIONS OF THE SUBSOIL INVESTIGATION ARE BEING IMPLEMENTED. THE
GEOTECHNICAL ENGINEER SHALL INSPECT ALL FOUNDATION EXCAVATIONS AND SLAB SUBGRADE
IMMEDIATELY PRIOR TO PLACEMENT OF ANY CONCRETE AND SHALL TEST ALL FILL FOR PROPER
COMPACTION.
2. FILL BELOW SLABS-ON-GRADE SHALL CONSIST OF CLEAN GRANULAR MATERIAL COMPACTED TO
95% TO 98% OF STANDARD PROCTOR DENSITY. SEE GEOTECHNICAL REPORT FOR COMPACTION
REQUIREMENTS.
3. ALL STRUCTURAL SLABS-ON-GRADE SHALL BEAR ON A SUB-BASE OF 6 INCHES OF CLEAN
AGGREGATE BASE. SEE GEOTECHNICAL REPORT FOR FILL REQUIREMENTS.
CONCRETE AND REINFORCING
1. CONCRETE WORK SHALL CONFORM TO ALL REQUIREMENTS OF ACI 318-08, "BUILDING CODE
REQUIREMENTS FOR STRUCTURAL CONCRETE," EXCEPT AS MODIFIED BY THE SUPPLEMENTAL
REQUIREMENTS BELOW. PLACEMENT SHALL CONFORM TO THE LATEST VERSION OF ACI 302.1R,
"GUIDE FOR CONCRETE FLOOR AND SLAB CONSTRUCTION."
2. CONCRETE SHALL ATTAIN A MINIMUM 28-DAY COMPRESSIVE STRENGTH OF 4,000 PSI. CONCRETE SHALL DEVELOP MINIMUM ULTIMATE COMPRESSIVE DESIGN STRENGTH OF 4,000 PSI IN 28 DAYS, BUT NOT LESS THAN 564 POUNDS OF CEMENT SHALL BE USED PER CUBIC YARD OF CONCRETE
REGARDLESS OF STRENGTH OBTAINED, 0.48 W/C RATIO, WITH 6% PLUS OR MINUS 1% AIR
ENTRAINMENT, AND NOT MORE THAN 4" OF SLUMP.
3. THE ADDITION OF WATER TO THE MIX ON SITE SHALL NOT BE ALLOWED. CONCRETE MAY NOT BE
PLACED DURING FREEZING WEATHER UNLESS SUITABLY PROTECTED PER ACI 306. CONFORM TO
ACI 305 FOR HOT WEATHER CONCRETING.
4. APPLY A BROOM FINISH TO SLAB SURFACE, UNLESS SPECIFIED OTHERWISE BY THE COURT-
COATING MANUFACTURER'S RECOMMENDATIONS.
5. CURE CONCRETE FLATWORK BY MOIST CURE ONLY FOR A MINIMUM OF 72 HOURS.
6. ALL REINFORCING STEEL SHALL BE ASTM A615, GRADE 60.
7. CONCRETE COVER AND MINIMUM LAP SPLICES OF REINFORCING SHALL CONFORM TO ACI 318, LATEST EDITION, UNLESS OTHERWISE DETAILED.
8. CONTRACTOR TO SUBMIT REINFORCING STEEL SHOP DRAWINGS INDICATING PLACEMENT,
SPACING, SIZE, AND LAP LENGTHS FOR REVIEW BY ENGINEER OF RECORD PRIOR TO FABRICATION.
9. CONTRACTOR SHALL VERIFY THAT ALL CONCRETE INSERTS, REINFORCING AND EMBEDDED ITEMS
ARE CORRECTLY LOCATED AND RIGIDLY SECURED PRIOR TO CONCRETE PLACEMENT.
10. ANY HORIZONTAL CONSTRUCTION JOINTS IN CONCRETE POURS NOT SHOWN ON THE DRAWINGS
SHALL BE SUBMITTED TO THE ENGINEER OF RECORD FOR REVIEW PRIOR TO COMMENCEMENT OF
CONSTRUCTION.
COORDINATION AND VERIFICATION
1. CONTRACTOR TO COORDINATE STRUCTURAL DRAWINGS WITH ARCHITECTURAL, MECHANICAL,
ELECTRICAL, AND CIVIL DRAWINGS FOR ADDITIONAL OPENINGS, SLEEVES, ETC, NOT SHOWN ON
THE STRUCTURAL DRAWINGS. COORDINATE LOCATION, SIZE, AND REINFORCEMENT OF ALL
OPENINGS WITH RESPECTIVE TRADES PRIOR TO FABRICATION.
2. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO STARTING WORK OR FABRICATING
ANY STRUCTURAL MATERIALS AND NOTIFY THE ENGINEER OF RECORD OF ANY DISCREPANCIES.
POST-TENSIONING
1. POST-TENSIONING TENDONS SHALL BE 0.5" DIAMETER, 270 KSI TENSILE STRENGTH LOW-
RELAXATION MONO-STRAND TENDONS, PLASTIC SHEATHED AND GREASED, WITH A MINIMUM
ULTIMATE LOAD CAPACITY OF 41.5 KIPS PER CABLE.
2. PROVIDE CERTIFIED MILL REPORTS AND OTHER TEST DATA AS SPECIFIED.
3. ENSURE THAT ANCHORAGES ARE POSITIONED ACCORDING TO THE DESIGN AND FIXED SO THE DO
NOT MOVE DURING NORMAL CONSTRUCTION ACTIVITIES. ENSURE THAT ANTI-BURST
REINFORCEMENT IS PRESENT AND FIXED CENTRAL TO ANCHORAGE.
4. PROVIDE SUPPORTS AND ACCESSORIES AS REQUIRED TO ASSURE PROPER CABLE POSITION
BEFORE, DURING, AND AFTER CONCRETE PLACEMENT. CONTINUALLY MONITOR CABLE PROFILES
DURING CONCRETE PLACEMENT TO AVOID DISPLACEMENT OF CABLES.
5. DURING CONCRETE PLACEMENT, CHECK THAT STRANDS ARE NOT DAMAGED BY CONCRETE. IF
DAMAGE OCCURS, NOTIFY CONCRETE CONTRACTOR AND ARRANGE FOR REPAIR.
6. AT COMPLETION OF CONCRETE PLACEMENT, CHECK THAT ALL ANCHORS ARE CLEAR OF SLURRY, ETC. CHECK THAT TEST CYLINDERS HAVE BEEN TAKEN DURING POUR AND STORED ON SITE IN
CONDITIONS SIMILAR TO SLAB BEING POURED.
7. THE FINAL TENSIONING OPERATION SHOULD NOT BEGIN UNTIL A MINIMUM CONCRETE
COMPRESSIVE STRENGTH OF 2,000 PSI HAS BEEN ATTAINED. TENDONS SHOULD NOT BE STRESSED
WHERE CRACKS, VOIDS, OR EXCESSIVE HONEYCOMBING IS VISIBLE AT ANCHORAGES.
8. INFORM THE SITE SUPERINTENDENT BEFORE STRESSING COMMENCES IN THE AREA. TAKE CARE
AND ENSURE THAT APPROPRIATE SAFETY PRECAUTIONS ARE TAKEN TO PROTECT FIELD
PERSONNEL CONDUCTING AND INSPECTING OPERATIONS.
9. POST-TENSIONING CABLES SHALL BE INSTALLED AS FOLLOWS:
A. UNDER DIRECT SUPERVISION OF SUPPLIER'S REPRESENTATIVE.
B. STRESS ALL CABLES TO 80% OF ULTIMATE.
C. SET ALL CABLES OFF AT 70% OF ULTIMATE.
D. USE HYDRAULIC JACKS, CALIBRATE JACKS BEFORE FIRST PULL.
E. MEASURE AND LOG ELONGATION OF EACH CABLE DURING STRESSING AND REPORT IN
WRITING TO ENGINEER OF RECORD. DO NOT CUT OFF STRESSED CABLE ENDS UNTIL ENGINEER
OF RECORD HAS REVIEWED AND ACCEPTED ELONGATIONS.
F. CUT ALL TENDONS, ENSURING THAT SPECIFIED CONCRETE COVER CAN BE ACHIEVED, USING
FRICTION CUTTER. DO NOT USE HEAT-TYPE CUTTING DEVICE.
10. POST-TENSIONING SUPPLIER TO VERIFY TENDON LAYOUT TO PROVIDE 150PSI EFFECTIVE STRESS
IN ACCORDANCE WITH PTI DC10.3 - DESIGN AND CONSTRUCTION OF POST- TENSIONED SPORT
COURTS.
'-0
'-0
'-0
206'-0"
206'-0"
S101
S101 drawn by:
checked by:
approved by:
QA/QC by:
project no.:
drawing no.:
date
SHEET
R E
V
IS
IO
N
S
R E
V
N O
D
A T
E R
E V
IS
IO
N D
E S
C R
IP
T
IO
N
:5 :0
P M
C R e vi t L o c a l F il e s S O tt u m w a
T e n n is
C o u rt s C e n tr a l_ c a ry s c h ro e d e r.
rv t
PKM
CWS
CWS
023-05957
10/17/2023
O T
T U
M W
A
IA
O T
T U
M W
A C
O M
M U
N
IT
Y S
C H
O O
L S
T E
N N
IS
C
O U
R T
S
P O
S T
-T E
N S
IO
N
S L A
B P
L A
N
O V
E R
A L L
S100 w w w .o ls so n.
co m
S ou th
7t h S tr ee t, S ui te
O m ah a, N E
T
E L
2.
1.
F A
X
.3
.5
E ng in ee rin g
N eb ra sk a
C O
A
C A
-0
SCALE = 1/16" = 1'-0"
1 SLAB PLAN - OVERALL
BID ALTERNATE #1:
1. CONTRACTOR TO PROVIDE BID ALTERNATE ELIMINATING POST-TENSIONING TENDONS.
2. REMOVE POST-TENSIONING TENDONS FROM DESIGN.
REPLACE 5" THICK POST-TENSIONED SLAB WITH 8" THICK MILD-REINFORCED SLAB ON
GRADE WITH #5 BARS AT 12" ON CENTER EACH WAY, CENTERED IN SLAB DEPTH.
3. ALL OTHER DETAILING REMAINS THE SAME.
NOTES:
1. INDICATES STRESSING DIRECTION AND STRESSING END ANCHORAGE FOR 5" POST-TENSIONED SLAB ON GRADE.
2. INDICATES DEAD END ANCHORAGE FOR 5" POST-TENSIONED SLAB ON GRADE.
3. 5" POST TENSIONED SLAB ON GRADE ON (1) LAYER OF 6 MIL AND (1) LAYER OF 10 MIL POYETHYLENE SHEETING ON 6" LIME SCREENINGS BASE ON COMPACTED SUBGRADE. APPLY SHEETING LAYERS NORMAL TO ONE ANOTHER AND TAPE OR SEAL SEAMS AND LAPS.
TENDON SYMBOL LEGEND - SHORT DIRECTION
S E
E P
L A
N S
E E
P L A
N
116'-0"
7 7/8" 9 5/8"
STRESSING REQ'D
AT BOTH ENDS.
TENDON NUMBER
AT STRESSING-END
MIN. TENDON LENGTH (ADDED
LENGTH FOR STRESSING TO BE
DETERMINED BY CONTRACTOR)
MINIMUM ELONGATION
MAXIMUM ELONGATION
SLAB TENDON
FIXED-END
ANCHORAGE PER
DETAIL INDICATED
ON PLANS
TENDON SYMBOL LEGEND - LONG DIRECTION
S E
E P
L A
N S
E E
P L A
N
206'-0"
17 1/4"14 1/8"
STRESSING REQ'D
AT BOTH ENDS.
TENDON NUMBER
AT STRESSING-END
MIN. TENDON LENGTH (ADDED
LENGTH FOR STRESSING TO BE
DETERMINED BY CONTRACTOR)
MINIMUM ELONGATION
MAXIMUM ELONGATION
SLAB TENDON
FIXED-END
ANCHORAGE PER
DETAIL INDICATED
ON PLANS
13'-0" 36'-0" 12'-0" 36'-0" 12'-0" 36'-0" 12'-0" 36'-0" 13'-0"
S200
S200
'-0
'-0
'-0
S200
S200
S200
TYP ALL EDGES
'-0
FENCE
'-9
T
E N
D O
N S
E Q
U A
L L Y
S P
A C
E D
A T
'-3
'-9
1'-8" TENDONS EQUALLY SPACED AT 2'-8" 1'-8"
206'-0"
12852 drawn by:
checked by:
approved by:
QA/QC by:
project no.:
drawing no.:
date
SHEET
R E
V
IS
IO
N
S
R E
V
N O
D
A T
E R
E V
IS
IO
N D
E S
C R
IP
T
IO
N
:5 :0
P M
C R e vi t L o c a l F il e s S O tt u m w a
T e n n is
C o u rt s C e n tr a l_ c a ry s c h ro e d e r.
rv t
PKM
CWS
CWS
023-05957
10/17/2023
O T
T U
M W
A
IA
O T
T U
M W
A C
O M
M U
N
IT
Y S
C H
O O
L S
T E
N N
IS
C
O U
R T
S
P O
S T
-T E
N S
IO
N
S L A
B P
L A
N
S101 w w w .o ls so n.
co m
S ou th
7t h S tr ee t, S ui te
O m ah a, N E
T
E L
2.
1.
F A
X
.3
.5
E ng in ee rin g
N eb ra sk a
C O
A
C A
-0
SCALE = 3/32" = 1'-0"
2 SLAB PLAN
2'-0" 2'-0" 12∆12∆
M
IN
STRESSING OR DEAD END
ANCHORAGE - SEE TENDON
LAYOUT PLAN (TYP)
(2) - #4 CONT.
EDGE OF SLAB
SLAB TENDONS
SEE LAYOUT SEE LAYOUT
1'-0"
S E
E L
A Y
O U
T
FENCE POST, BY OTHERS. PROVIDE
1" COMPRESSIBLE JOINT MATL. ALL
AROUND POST FOR FULL DEPTH OF
SLAB PENETRATION. INSTALL
SEALANT ALL AROUND AT TOP OF
JOINT. SEE GENERAL NOTES.
#4 X 6'-0" HAIRPIN BAR
AT EACH POST
PLACE HAIRPIN WITH
1-1/2" CLR FROM TOP
OF SLAB
3'-0"
3'-0"
1 1/2"CLR
FENCE POST, BY OTHERS.
PROVIDE 1" COMPRESSIBLE
JOINT MATL. ALL AROUND POST FOR
FULL DEPTH OF SLAB PENETRATION.
INSTALL SEALANT ALL AROUND AT TOP
OF JOINT. SEE NOTES
STRESSING OR DEAD END
ANCHORAGE - SEE TENDON
LAYOUT PLAN (TYP)
2 - #4 CONT. - LAP 2'-0"" MIN.
AS REQUIRED (TYP)
EDGE OF SLAB
1/2"Ø SLAB TENDONS1/2"Ø SLAB TENDONS1/2"Ø SLAB TENDONS
SEE LAYOUT SEE LAYOUT
1'-0"
L A
Y O
U T
S E
E S
E E
L A
Y O
U T
2 - #4 CONT.
2'-0"
'-0
#4 X 6'-0" HAIRPIN BAR
AT EA. FENCH POST
PLACE HAIRPIN WITH
1-1/2" CLR. FROM TOP
OF SLAB
3'-0"
3'-0"
1 1/2"CLR
R E
Q D
A S
AS REQUIRED
(1) LAYER OF 6 MIL TOP, (1) LAYER OF 10 MIL
BOTTOM POLYETHYLENE SHEETING. APPLY
LAYERS NORMAL TO EACH OTHER AND
TAPE OR SEAL SEAMS AND LAPS
SUBGRADE
STRAP ANCHOR FOUNDATION
MONOLITHIC W/ TENNIS COURTS
CENTER STRAP ANCHOR SET FLUSH W/
TOP OF CONCRETE PRIOR TO
POUR
POST-TENSIONED
TENNIS COURT SLAB
/2
/2
6" LIME SCREENINGS BASE
POST
POCKET FORMER
STRESSING OR DEAD END
ANCHORAGE - SEE TENDON
LAYOUT PLAN (TYP)
1'-0"
POST-TENSION SLAB
T/SLAB
1" COMPRESSIBLE JT. MATL.
ALL AROUND FENCE POST
W/ SEALANT
FENCE POST FTG.,
BY OTHERS
NOTE: CONTRACTOR SHALL USE EXTREME CARE IN PLACING
CONCRETE FOR FENCE POST FOOTINGS. TOP OF FOOTING
SHALL BE SMOOTH AND LEVEL AND PLACED A MINIMUM OF
2" BELOW BOTTOM OF SLAB THICKENED EDGE. TAMP FILL
OVER FOOTING AND COVER WITH 2 LAYERS OF 10 MIL
POLYETHYLENE SHEETING. SLAB MUST BE ISOLATED FROM
FOOTING AND POST. WRAP POSTS WITH 1" MIN.
THICKNESS COMPRESSIBLE JOINT MATERIAL FOR FULL DEPTH
OF SLAB.
(1) LAYER OF 6 MIL TOP, (1)
LAYER OF 10 MIL BOTTOM
POLYETHYLENE SHEETING.
APPLY LAYERS NORMAL TO
EACH OTHER AND TAPE OR
SEAL SEAMS AND LAPS
6" LIME SCREENINGS BASE
COMPACTED SUBGRADE
HAIRPIN BAR - SEE SLAB EDGE DETAILS
/2
/2
CONCRETE BASE SHALL BE
DUG/DRILLED PRIOR TO POST
TENSIONED CONCRETE SLAB BEING
FORMED, BUT HOLE/SLEEVE/POST
SHALL BE PROTECTED DURING SLAB
PLACEMENT OR POST INSTALLED
AFTER SLAB HAS BEEN PLACED.
NET POST SLEEVE, BY OTHERS
BONDBREAKER (1) LAYER OF 6 MIL AND (1)
LAYER OF 10 MIL POLYETHYLENE SHEETING
POST TENSIONED
CONCRETE COURT SLAB
TENNIS NET, BY OTHERS
NET POST, BY OTHERS
1" COMPRESSIBLE JT.
MATL. W/ SEALANT
ALL AROUND NET POST
NET TENSIONER,
BY OTHERS
NOTES:
1. DIMENSIONS SHOWN ARE MINIMUMS ONLY.
COORDINATE FOUNDATION REQUIREMENTS
WITH POST ANCHOR MANUFACTURER.
2. USE EXTREME CARE TO SET ELEVATIONS OF
TOP OF NET POST FOUNDATION AT OR BELOW
BOTTOM OF SLAB ELEVATION.
'-6
'-6
M
IN
DIAMETER
1'-6" MIN.
drawn by:
checked by:
approved by:
QA/QC by:
project no.:
drawing no.:
date
SHEET
R E
V
IS
IO
N
S
R E
V
N O
D
A T
E R
E V
IS
IO
N D
E S
C R
IP
T
IO
N
:5 :0
P M
C R e vi t L o c a l F il e s S O tt u m w a
T e n n is
C o u rt s C e n tr a l_ c a ry s c h ro e d e r.
rv t
PKM
CWS
CWS
023-05957
10/17/2023
O T
T U
M W
A
IA
O T
T U
M W
A C
O M
M U
N
IT
Y S
C H
O O
L S
T E
N N
IS
C
O U
R T
S
D E
T A
IL
S
P
O S
T -T
E N
S
IO
N
S200
SCALE = 1/2" = 1'-0"
1 CURVATURE OF TENDONS AT PENETRATIONS DETAIL
SCALE = 3/4" = 1'-0"
5 FENCE POST DETAIL
SCALE = 3/4" = 1'-0"
2 CENTER STRAP ANCHOR SECTION
SCALE = 3/4" = 1'-0"
6 NET POST SECTION
SCALE = 3/4" = 1'-0"
3 SLAB EDGE DETAIL
SCALE = 3/4" = 1'-0"
4 SLAB CORNER DETAIL - NO HAIRPIN
w w w .o ls so n.
co m
S ou th
7t h S tr ee t, S ui te
O m ah a, N E
T
E L
2.
1.
F A
X
.3
.5
E ng in ee rin g
N eb ra sk a
C O
A
C A
-0
| Sheets |
| G000 - COVER SHEET |
| S001 - POST-TENSION SLAB NOTES AND SPECIAL INSPECTION SCHEDULE |
| S100 - POST-TENSION SLAB PLAN - OVERALL |
| S101 - POST-TENSION SLAB PLAN |
| S200 - DETAILS - POST-TENSION |
File details come from the government source that posted it. Updated .