Product Specifications.pdf
PDF 85 KB Posted
- Solicitation number
- N0025922Q0031
About this file
This is a request for quotation (RFQ) from the Department of the Navy Naval Supply Systems Command seeking firm fixed price quotations for the BioFire Respiratory Panel 2.1 (RP2.1) Reagent Kit product code #423742 with an expiration date of 3/15/2023 or later. The RFQ requires delivery of 45 kits on 5/18/2022 and 45 kits on 9/14/2022. Quotes must be received by 12:01pm PST on 4/15/2022 and include pricing, point of contact information, business size, and payment terms. The source selection method is lowest price technically acceptable. The RFQ incorporates standard Federal Acquisition Regulation clauses on small business subcontracting, equal opportunity, combating trafficking in persons, and electronic funds transfer.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
The BioFire® Respiratory
2.1 (RP2.1) Panel 1 Test. 22 Targets. ~45 Minutes.
The BioFire RP2.1 Panel Targets
VIRUSES
Adenovirus Coronavirus 229E Coronavirus HKU1 Coronavirus NL63 Coronavirus OC43 Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) Human Metapneumovirus Human Rhinovirus/Enterovirus Influenza A
Influenza A/H1 Influenza A/H3 Influenza A/H1-2009 Influenza B Parainfluenza Virus 1 Parainfluenza Virus 2 Parainfluenza Virus 3 Parainfluenza Virus 4 Respiratory Syncytial Virus
BACTERIA
Bordetella parapertussis Bordetella pertussis Chlamydia pneumoniae Mycoplasma pneumoniae
COVID-19 and the Value of the Syndromic Approach
Study results suggest higher rates of co-infection between SARS-CoV-2 and other respiratory pathogens than previously reported. In some cases, as many as 20% of COVID-19 patients have co-infections with another respiratory virus.1 Because respiratory symptoms are similar and overlapping, a syndromic panel can provide fast, comprehensive answers and take the guesswork out of choosing which pathogens to test for.
Co-infection for SARS-CoV-2 Positive Patients1
Only Infected with SARS-CoV-2
Co-infection with Another Respiratory Virus
79.3%
20.7%
BFR0001-3107-01
Part Number
BioFire RP2.1 Reagent Kit (30 Pouches): 423742
Sample Type: Nasopharyngeal swab in transport media or saline Sample Volume: 0.3 mL
Hands-On Time: approximately 2 minutes Storage Conditions: All kit components stored at room temperature (15-25 ˚C)
Overall Performance: 97.1% sensitivity, 99.3% specificity7 SARS-CoV-2 Performance: 98.4% PPA, 98.9% NPA8
Panel Specifications
The BioFire RP Panel resulted in avoidance of antibiotics in 30% of pediatric patients tested.6
Help Guide Antimicrobial Stewardship Programs
The US CDC estimates that 50% of outpatient prescriptions for acute respiratory conditions are unnecessary, contributing to increased levels of antibiotic resistance.5 Use of the BioFire RP Panel has been shown to reduce antibiotic use by identifying respiratory viruses in a clinically actionable timeframe.6
Knowing the Pathogen Matters
Reduce Length of Stay The hospital length of stay was nearly 5 days less for febrile infants with a positive BioFire RP Panel result compared to those with a negative result.4
Reduce Unnecessary Testing Use of the BioFire RP Panel was shown to reduce chest radiographs in children by 19%.3
Inform Clinical Decisions Respiratory infections can be characterized by similar symptoms, making diagnosis difficult.
The BioFire® FilmArray® Respiratory (RP) Panel was shown to increase diagnostic yield by 30%, compared to traditional testing methods.2
45%
15%
BioFire RP Panel
Traditional Testing
References
1. Kim, D et al. (2020) JAMA doi:10.1001/jama.2020.6266
2. Brendish et al. (2017) Lancet Respiratory Medicine. 5(5):401.
3. Subramony A, Zachariah P, Krones A, Whittier S, Saiman L. J Pediatr. 2016; doi: 10.1016/j.jpeds.2016.02.050016.02.050.
4. McFall, et al., Pediatrics. 2017 Feb;:000992281774066.
5. CDC. Antibiotic Use in the United States, 2017: Progress and Opportunities. Atlanta, GA: US Department of Health and Human Services, CDC; 2017.
6. Sutton C, Walton P, Williams M, Bastian T, Wright M, Spires S. Impact of Multiplex Polymerase Chain Reaction Testing for Respiratory Pathogen Detection in Pediatric Patients, ID Week 2017, poster 1607.
7. Overall performance based on prospective clinical study for the BioFire® FilmArray® Respiratory 2 Panel, Data on file, BioFire Diagnostics.
8. Overall performance based on prospective SARS-COV-2 clinical study for the BioFire® Respiratory 2.1 Panel in comparison to 3 EUA tests, Data on file, BioFire Diagnostics.
Contact Us
Phone: +1-801-736-6354 x 2
Email: sales@biofiredx.com biofiredx.com
FDA-Cleared
File details come from the government source that posted it. Updated .