POSTING FBR 1691-25 Precast Concrete - Google Docs.pdf

PDF 4 MB Posted

Attached to
298-FBR1691-25 Precast Concrete
Solicitation number
298-298-FBR1691-25
Issued by
Buncombe County, Asheville City, North Carolina

About this file

This document is a Formal Bid Request (FBR) issued by the City of Asheville, North Carolina for precast concrete materials for the Stormwater Division of the City's Public Works Department. The FBR seeks to establish a 12-month term contract with two optional 12-month renewal periods for the supply of various precast concrete products such as catch basins, risers, and lids. The FBR provides detailed specifications for each item, including size, material composition, and compliance with NCDOT and City of Asheville standards. Bidders must submit their responses by 3:00 PM local time on August 22, 2024, at which point bids will be publicly opened and read. The City reserves the right to award the contract to the lowest, responsive, and responsible bidder.

The FBR specifies that pricing must be FOB Destination, with all freight/delivery costs included in the unit price. The City will not accept any additional freight charges. The contract will utilize a market-based material escalation/de-escalation clause for potential price adjustments during the renewal periods. The City is exempt from federal excise tax but not state and local sales tax. The FBR also outlines the City's Asheville Business Inclusion Policy to encourage participation from women and minority-owned businesses.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

REQUEST FOR BIDS

FORMAL BID REQUEST NO. FBR 1691-25

PRECAST CONCRETE

FOR THE CITY OF ASHEVILLE

QUESTIONS DUE BY WEDNESDAY, AUGUST 14, 2024

BY 3:00 PM LOCAL TIME

BID OPENING DATE: THURSDAY, AUGUST 22, 2024

AT 3:00 PM LOCAL TIME

ISSUED BY: CITY OF ASHEVILLE PURCHASING DIVISION

70 COURT PLAZA, CITY HALL, 1 ST FLOOR

ASHEVILLE, NC 28801

PHONE: (828) 259-5950

TAWNYA VESS, PURCHASING SPECIALIST

08/07/2024

BIDS ARE TO BE SEALED AND

HAND DELIVERED TO THE CITY OF ASHEVILLE’S FORMAL BID DROPBOX

OR SENT BY COURIER SUCH AS: UPS OR FEDEX TO THE CITY OF ASHEVILLE

70 COURT PLAZA, SUITE 100A, ASHEVILLE, NC 28801

*PLEASE NOTE: IT IS THE RESPONSIBILITY OF THE BIDDER TO ENSURE WHATEVER

METHOD OF DELIVERY IS USED THAT THE BID IS RECEIVED ON TIME

Formal Bid Request FBR 1691-25 1

REQUEST FOR BIDS FOR

CITY OF ASHEVILLE, NORTH CAROLINA

PURCHASING DIVISION

Pursuant to General Statutes of North Carolina, Section 143-129, as amended, sealed bids and proposals, subject to the conditions and specifications herein, are invited for furnishing the following equipment, materials, services or repair work. All bids will be received by the City of Asheville Purchasing Division until: 3:00 p.m. local time on Thursday, August 22, 2024 after which time they will be publicly opened and read.

TERMS: Net 30 Days CITY OF ASHEVILLE, N. C.

DELIVERY: ASAP - Bidder Specify Best Delivery Tawnya Vess, Purchasing Specialist

POSITIVELY NO BIDS CONSIDERED UNLESS SUBMITTED ON THIS FORM

NOTICE TO BIDDERS: All tax imposed upon any article on which you are bidding shall be shown as separate items and in no case included with price bid. Failure to comply with these conditions will be considered grounds for rejection.

Bid request to establish a (12) Month Term Contract for Precast Concrete per the enclosed Bid Sheets, Specifications, and Terms and Conditions. Per Terms and Conditions the PO/Contract will hold two options to renew.

Quantities shown are an estimated amount for a 12 Month Term Period, and are not a guaranteed purchase amount.

All pricing to be FOB Destination .

ANY AND ALL FREIGHT/DELIVERY CHARGES MUST BE INCLUDED IN THE UNIT

PRICE ON THE QUOTE FORM FOR THE PRECAST CONCRETE. NO ADDITIONAL

FREIGHT/DELIVERY CHARGES WILL BE ALLOWED ON INVOICE.

Orders will be placed throughout the term of this contract on an as needed basis.

Deadline for any and all questions is 3:00 p.m., Wednesday, August 14, (Exceptions also include any issues with the specifications, unavailable options, etc.)

THIS BID WILL BE AWARDED TO ONE VENDOR

Company Name Bid Submitted By (Signature)

Address Printed Name and Title

City State Zip Email Address

Telephone No. Fax No.

Web Address Federal Taxpayer ID No.

Delivery to City __________ calendar days after receipt of order Payment Terms: Net ____________ Discount:_______% Net ________

Bid Submitted By: Company _____________________________________ Rep. Name __________________________

Formal Bid Request FBR 1691-25 2

INSTRUCTIONS TO BIDDERS:

Delivery of Bids:

1) All bids should be submitted in a sealed (glued/taped)envelope, the outside should be clearly marked with the bid number and the date and time scheduled for the opening of the bid.

2) Bids may be delivered to the Purchasing bid drop box located inside City Hall at the Security Station. The drop box is labeled “Formal Bid Dropbox”

3) Courier Delivery such as UPS or FedEx: All Courier deliveries can be addressed to:

City of Asheville 70 Court Plaza (Security Station) Asheville, NC 28801

Attn: Tawnya Vess

Bid #: FBR 1691-25 Precast Concrete

Bids must be received by 3:00pm on August 22, 2024

*PLEASE NOTE: IT IS THE RESPONSIBILITY OF THE BIDDER TO ENSURE WHATEVER METHOD OF DELIVERY IS USED

THAT THE BID IS RECEIVED ON TIME.

Bid Submitted By: Company _____________________________________ Rep. Name __________________________

Formal Bid Request FBR 1691-25 3

BID FORM

All pricing to be FOB Destination Unit Price must include the cost of shipping/delivery

Quantities are estimates. Those parts listed with a quantity of one (1) may or may not be ordered. You must provide accurate cost as the quantity may increase if needed and we are simply wanting a price and may not be calculated into the total bid price. Low bids may be reviewed for accuracy.

ITEM

NO.

EST.

ANNUAL

QTY.

ITEM DESCRIPTION Manufacturer/ Product #

UNIT

PRICE

EXTENDED

COST

PRECAST CONCRETE

Catch Basins:

1 100 EA 27” x 3’ x 3’ Concrete Catch Basin with Waffle Knockouts

2 100 EA 3’ x 3’ x 3’ Concrete Catch Basin with Waffle Knockouts

3 20 EA 4’ x 4’ x 4’ Concrete Catch Basin with Waffle Knockouts

4 50 EA 27” x 3’ x 3’ Concrete Catch Basin Solid Wall $ $

5 50 EA 3’ x 3’ x 3’ Concrete Catch Basin Solid Wall $ $

6 20 EA 4’ x 4’ x 4’ Concrete Catch Basin Solid Wall $ $

Subtotal:

DELIVERY ON ITEMS IN THIS SUBGROUP WILL BE

MADE WITHIN _____ DAYS (show in column at right)

Risers:

7 25 EA 27”x3’x6”’ Concrete solid wall riser $ $

8 25 EA 27”x3’x1’ Concrete solid wall riser $ $

9 25 EA 27”x3’x2’ Concrete solid wall riser $ $

10 25 EA 27”x3’x3’ Concrete solid wall riser $ $

11 25 EA 27”x3’x3’ Concrete riser with waffle knockouts $ $

12 25 EA 3’x3’x6” Concrete solid wall riser $ $

Bid Submitted By: Company _____________________________________ Rep. Name __________________________

Formal Bid Request FBR 1691-25 4 13 25 EA 3’x3’x1’ Concrete solid wall riser $ $

14 25 EA 3’x3’x2’ Concrete solid wall riser $ $

15 25 EA 3’x3’x3’ Concrete solid wall riser $ $

16 25 EA 3’x3’x3’ Concrete riser with waffle knockouts $ $

17 10 EA 4’x4’x6” Concrete solid wall riser $ $

18 10 EA 4’x4’x1’ Concrete solid wall riser $ $

19 10 EA 4’x4’x2’ Concrete solid wall riser $ $

20 10 EA 4’x4’x3’ Concrete solid wall riser $ $

21 10 EA 4’x4’x4’ Concrete riser with waffle knockouts $ $

Subtotal:

DELIVERY ON ITEMS IN THIS SUBGROUP WILL BE

MADE WITHIN _____ DAYS (show in column at right)

Lids with 24” Hole in center:

22 25 EA 3’x3’x6” Lids with 24” Hole in center $ $

23 25 EA 39”x4’x6” Lids with 24” Hole in center $ $

24 25 EA 4’x4’x6” Lids with 24” Hole in center $ $

25 1 EA 4’x5’x6” Lids with 24” Hole in center $ $

26 10 EA 5’x5’x6” Lids with 24” Hole in center $ $

27 1 EA 5’x6’x6” Lids with 24” Hole in center $ $

Subtotal:

DELIVERY ON ITEMS IN THIS SUBGROUP WILL BE

MADE WITHIN _____ DAYS (show in column at right)

Lids with ring and cover cast in:

28 10 EA 3’x3’x6” Lids with ring and cover cast in $ $

29 30 EA 39”x4’x6” Lids with ring and cover cast in $ $

30 30 EA 4’x4’x6” Lids with ring and cover cast in $ $

31 1 EA 4’x5’x6” Lids with ring and cover cast in $ $

Bid Submitted By: Company _____________________________________ Rep. Name __________________________

Formal Bid Request FBR 1691-25 5 32 1 EA 4’x6’x6” Lids with ring and cover cast in $ $

33 10 EA 5’x5’x6” Lids with ring and cover cast in $ $

34 1 EA 5’x6’x6” Lids with ring and cover cast in $ $

Subtotal:

DELIVERY ON ITEMS IN THIS SUBGROUP WILL BE

MADE WITHIN _____ DAYS (show in column at right)

Concrete Grade Rings:

35 25 EA 2” Concrete Grade Rings; Round for Manholes $ $

36 25 EA 4” Concrete Grade Rings; Round for Manholes $ $

37 25 EA 6” Concrete Grade Rings; Round for Manholes $ $

Subtotal:

DELIVERY ON ITEMS IN THIS SUBGROUP WILL BE

MADE WITHIN _____ DAYS (show in column at right)

GRAND TOTAL: $

Bid Submitted By: Company _____________________________________ Rep. Name __________________________

Formal Bid Request FBR 1691-25 6

SPECIFICATIONS

NEW and UNUSED equipment only **No Additional Freight For Delivery Allowed** *Do Not Include Sales Tax in your the quote*

Review of bid specification sheets will focus on the compliance column with deviations noting where specifications exceed minimum requirements ONLY. Compliance deviations that do not meet or exceed the minimum requests will not be accepted.

NOTE : All bidders shall respond to each category below. Any 'no' responses or deviations shall be explained in the space provided. If it complies, put a check mark in the appropriate box.

SPECIFICATION COMPLIES IF NO: DEVIATES

AS NOTED

ITEM 1. 27” x 3’ x 3’ Concrete Catch Basin with Waffle Knockouts

A. 4000 PSI Minimum Compressive Strength Concrete

B. ASTM A615 Grade 60 reinforcing steel

C. Meets ASTM C913 standards

D. Meets NCDOT Standard Drawing 840.45

E. Meets NCDOT Standard 1077

F. Meets City of Asheville Standard & Specification Section 8B.03: Structure Materials All storm drainage structures such as manholes, inlets, junction boxes, catch basins, endwalls and headwalls shall be constructed of solid brick, solid block, or precast concrete meeting NCDOT standards. Any structure with a depth greater than 4 feet shall have steps installed. All hoods, frames, and grates shall be domestically produced cast iron or steel and approved by NCDOT.

G. Meets City of Asheville Standard Detail 8.03 and 8.03A

H. NCDOT Certified/Stamped/Approved with inspection paperwork provided upon delivery

I. From sources on NCDOT’s Approved Producer / Supplier List for Precast Concrete

J. Advance Delivery Notification: Vendor must call 24 hours in advance to schedule a mutually agreeable delivery time. Hours are Monday - Thursday 7:00am - 3:30pm. Note: The City will not pay overtime for late deliveries. Deliveries must be unloaded and inspected prior to 3:30pm, any overtime after that will be charged back to the vendor.

Bid Submitted By: Company _____________________________________ Rep. Name __________________________

Formal Bid Request FBR 1691-25 7

Review of bid specification sheets will focus on the compliance column with deviations noting where specifications exceed minimum requirements ONLY. Compliance deviations that do not meet or exceed the minimum requests will not be accepted.

NOTE : All bidders shall respond to each category below. Any 'no' responses or deviations shall be explained in the space provided. If it complies, put a check mark in the appropriate box.

SPECIFICATION COMPLIES IF NO: DEVIATES

AS NOTED

ITEM 2. 3’ x 3’ x 3’ Concrete Catch Basin with Waffle Knockouts

A. 4000 PSI Minimum Compressive Strength Concrete

B. ASTM A615 Grade 60 reinforcing steel

C. Meets ASTM C913 standards

D. Meets NCDOT Standard Drawing 840.45

E. Meets NCDOT Standard 1077

F. Meets City of Asheville Standard & Specification Section 8B.03: Structure Materials All storm drainage structures such as manholes, inlets, junction boxes, catch basins, endwalls and headwalls shall be constructed of solid brick, solid block, or precast concrete meeting NCDOT standards. Any structure with a depth greater than 4 feet shall have steps installed. All hoods, frames, and grates shall be domestically produced cast iron or steel and approved by NCDOT.

G. Meets City of Asheville Standard Detail 8.03 and 8.03A

H. NCDOT Certified/Stamped/Approved with inspection paperwork provided upon delivery

I. From sources on NCDOT’s Approved Producer / Supplier List for Precast Concrete

J. Advance Delivery Notification: Vendor must call 24 hours in advance to schedule a mutually agreeable delivery time. Hours are Monday - Thursday 7:00am - 3:30pm. Note: The City will not pay overtime for late deliveries. Deliveries must be unloaded and inspected prior to 3:30pm, any overtime after that will be charged

Bid Submitted By: Company _____________________________________ Rep. Name __________________________

Formal Bid Request FBR 1691-25 8

Review of bid specification sheets will focus on the compliance column with deviations noting where specifications exceed minimum requirements ONLY. Compliance deviations that do not meet or exceed the minimum requests will not be accepted.

NOTE : All bidders shall respond to each category below. Any 'no' responses or deviations shall be explained in the space provided. If it complies, put a check mark in the appropriate box.

SPECIFICATION COMPLIES IF NO: DEVIATES

AS NOTED

ITEM 3. 4’ x 4’ x 4’ Concrete Catch Basin with Waffle Knockouts

A. 4000 PSI Minimum Compressive Strength Concrete

B. ASTM A615 Grade 60 reinforcing steel

C. Meets ASTM C913 standards

D. Meets NCDOT Standard Drawing 840.45

E. Meets NCDOT Standard 1077

F. Meets City of Asheville Standard & Specification Section 8B.03: Structure Materials All storm drainage structures such as manholes, inlets, junction boxes, catch basins, endwalls and headwalls shall be constructed of solid brick, solid block, or precast concrete meeting NCDOT standards. Any structure with a depth greater than 4 feet shall have steps installed. All hoods, frames, and grates shall be domestically produced cast iron or steel and approved by NCDOT.

G. Meets City of Asheville Standard Detail 8.03 and 8.03A

H. NCDOT Certified/Stamped/Approved with inspection paperwork provided upon delivery

I. From sources on NCDOT’s Approved Producer / Supplier List for Precast Concrete

J. Advance Delivery Notification: Vendor must call 24 hours in advance to schedule a mutually agreeable delivery time. Hours are Monday - Thursday 7:00am - 3:30pm. Note: The City will not pay overtime for late deliveries. Deliveries must be unloaded and inspected prior to 3:30pm, any overtime after that will be charged

Bid Submitted By: Company _____________________________________ Rep. Name __________________________

Formal Bid Request FBR 1691-25 9

Drawings Associated with Items 1- 3

NCDOT 840.45.pdf

Bid Submitted By: Company _____________________________________ Rep. Name __________________________ https://drive.google.com/file/d/11O1tlWyI31W-M2yeQKyPdGIFCo9RIBgf/view?usp=drive_link

Formal Bid Request FBR 1691-25 10

Bid Submitted By: Company _____________________________________ Rep. Name __________________________

Formal Bid Request FBR 1691-25 11

COA 8.03A.pdf

Bid Submitted By: Company _____________________________________ Rep. Name __________________________ https://drive.google.com/file/d/1kcJaLexosvR1rZVupNDgDUkyyigPIAwL/view?usp=drive_link

Formal Bid Request FBR 1691-25 12

COA 8.03.pdf

Bid Submitted By: Company _____________________________________ Rep. Name __________________________ https://drive.google.com/file/d/1joAugva9QYrj_8U5MJ3pnSTRlqW8qwM-/view?usp=drive_link

Formal Bid Request FBR 1691-25 13

NEW and UNUSED equipment only **No Additional Freight For Delivery Allowed** *Do Not Include Sales Tax in your the quote*

Review of bid specification sheets will focus on the compliance column with deviations noting where specifications exceed minimum requirements ONLY. Compliance deviations that do not meet or exceed the minimum requests will not be accepted.

NOTE : All bidders shall respond to each category below. Any 'no' responses or deviations shall be explained in the space provided. If it complies, put a check mark in the appropriate box.

SPECIFICATION COMPLIES IF NO: DEVIATES

AS NOTED

ITEM 4. 27” x 3’ x 3’ Concrete Catch Basin Solid Wall

A. 4000 PSI Minimum Compressive Strength Concrete

B. ASTM A615 Grade 60 reinforcing steel

C. Meets ASTM C913 standards

D. Meets NCDOT Standard Drawing 840.46

E. Meets NCDOT Standard 1077

F. Meets City of Asheville Standard & Specification Section 8B.03: Structure Materials All storm drainage structures such as manholes, inlets, junction boxes, catch basins, endwalls and headwalls shall be constructed of solid brick, solid block, or precast concrete meeting NCDOT standards. Any structure with a depth greater than 4 feet shall have steps installed. All hoods, frames, and grates shall be domestically produced cast iron or steel and approved by NCDOT.

G. Meets City of Asheville Standard Detail 8.03 and 8.03A

H. NCDOT Certified/Stamped/Approved with inspection paperwork provided upon delivery

I. From sources on NCDOT’s Approved Producer / Supplier List for Precast Concrete

J. Advance Delivery Notification: Vendor must call 24 hours in advance to schedule a mutually agreeable delivery time. Hours are Monday - Thursday 7:00am - 3:30pm. Note: The City will not pay overtime for late deliveries. Deliveries must be unloaded and inspected prior to 3:30pm, any overtime after that will be charged

Bid Submitted By: Company _____________________________________ Rep. Name __________________________

Formal Bid Request FBR 1691-25 14

Review of bid specification sheets will focus on the compliance column with deviations noting where specifications exceed minimum requirements ONLY. Compliance deviations that do not meet or exceed the minimum requests will not be accepted.

NOTE : All bidders shall respond to each category below. Any 'no' responses or deviations shall be explained in the space provided. If it complies, put a check mark in the appropriate box.

SPECIFICATION COMPLIES IF NO: DEVIATES

AS NOTED

ITEM 5. 3’ x 3’ x 3’ Concrete Catch Basin Solid Wall

A. 4000 PSI Minimum Compressive Strength Concrete

B. ASTM A615 Grade 60 reinforcing steel

C. Meets ASTM C913 standards

D. Meets NCDOT Standard Drawing 840.46

E. Meets NCDOT Standard 1077

F. Meets City of Asheville Standard & Specification Section 8B.03: Structure Materials All storm drainage structures such as manholes, inlets, junction boxes, catch basins, endwalls and headwalls shall be constructed of solid brick, solid block, or precast concrete meeting NCDOT standards. Any structure with a depth greater than 4 feet shall have steps installed. All hoods, frames, and grates shall be domestically produced cast iron or steel and approved by NCDOT.

G. Meets City of Asheville Standard Detail 8.03 and 8.03A

H. NCDOT Certified/Stamped/Approved with inspection paperwork provided upon delivery

I. From sources on NCDOT’s Approved Producer / Supplier List for Precast Concrete

J. Advance Delivery Notification: Vendor must call 24 hours in advance to schedule a mutually agreeable delivery time. Hours are Monday - Thursday 7:00am - 3:30pm. Note: The City will not pay overtime for late deliveries. Deliveries must be unloaded and inspected prior to 3:30pm, any overtime after that will be charged

Bid Submitted By: Company _____________________________________ Rep. Name __________________________

Formal Bid Request FBR 1691-25 15

Review of bid specification sheets will focus on the compliance column with deviations noting where specifications exceed minimum requirements ONLY. Compliance deviations that do not meet or exceed the minimum requests will not be accepted.

NOTE : All bidders shall respond to each category below. Any 'no' responses or deviations shall be explained in the space provided. If it complies, put a check mark in the appropriate box.

SPECIFICATION COMPLIES IF NO: DEVIATES

AS NOTED

ITEM 6. 4’ x 4’ x 4’ Concrete Catch Basin Solid Wall

A. 4000 PSI Minimum Compressive Strength Concrete

B. ASTM A615 Grade 60 reinforcing steel

C. Meets ASTM C913 standards

D. Meets NCDOT Standard Drawing 840.46

E. Meets NCDOT Standard 1077

F. Meets City of Asheville Standard & Specification Section 8B.03: Structure Materials All storm drainage structures such as manholes, inlets, junction boxes, catch basins, endwalls and headwalls shall be constructed of solid brick, solid block, or precast concrete meeting NCDOT standards. Any structure with a depth greater than 4 feet shall have steps installed. All hoods, frames, and grates shall be domestically produced cast iron or steel and approved by NCDOT.

G. Meets City of Asheville Standard Detail 8.03 and 8.03A

H. NCDOT Certified/Stamped/Approved with inspection paperwork provided upon delivery

I. From sources on NCDOT’s Approved Producer / Supplier List for Precast Concrete

J. Advance Delivery Notification: Vendor must call 24 hours in advance to schedule a mutually agreeable delivery time. Hours are Monday - Thursday 7:00am - 3:30pm. Note: The City will not pay overtime for late deliveries. Deliveries must be unloaded and inspected prior to 3:30pm, any overtime after that will be charged

Bid Submitted By: Company _____________________________________ Rep. Name __________________________

Formal Bid Request FBR 1691-25 16

Drawings Associated with Items 4 - 6

NCDOT 840.46

Bid Submitted By: Company _____________________________________ Rep. Name __________________________ https://drive.google.com/file/d/1jTA0-G4EWKa_-6fAANIjgfJSZ5OtIv9u/view?usp=drive_link

Formal Bid Request FBR 1691-25 17

Bid Submitted By: Company _____________________________________ Rep. Name __________________________

Formal Bid Request FBR 1691-25 18

Bid Submitted By: Company _____________________________________ Rep. Name __________________________

Formal Bid Request FBR 1691-25 19

Review of bid specification sheets will focus on the compliance column with deviations noting where specifications exceed minimum requirements ONLY. Compliance deviations that do not meet or exceed the minimum requests will not be accepted.

NOTE : All bidders shall respond to each category below. Any 'no' responses or deviations shall be explained in the space provided. If it complies, put a check mark in the appropriate box.

SPECIFICATION COMPLIES IF NO: DEVIATES

AS NOTED

ITEM 7. 27”x3’x6” Concrete solid wall riser

A. 4000 PSI Minimum Compressive Strength Concrete

B. ASTM A615 Grade 60 reinforcing steel

C. Meets ASTM C913 standards

D. Meets NCDOT Standard Drawing 840.45 and 840.46

E. Meets NCDOT Standard 1077

F. Meets City of Asheville Standard & Specification Section 8B.03: Structure Materials All storm drainage structures such as manholes, inlets, junction boxes, catch basins, endwalls and headwalls shall be constructed of solid brick, solid block, or precast concrete meeting NCDOT standards. Any structure with a depth greater than 4 feet shall have steps installed. All hoods, frames, and grates shall be domestically produced cast iron or steel and approved by NCDOT.

G. Meets City of Asheville Standard Detail 8.03 and 8.03A

H. NCDOT Certified/Stamped/Approved with inspection paperwork provided upon delivery

I. From sources on NCDOT’s Approved Producer / Supplier List for Precast Concrete

J. Advance Delivery Notification: Vendor must call 24 hours in advance to schedule a mutually agreeable delivery time. Hours are Monday - Thursday 7:00am - 3:30pm. Note: The City will not pay overtime for late deliveries. Deliveries must be unloaded and inspected prior to 3:30pm, any overtime after that will be charged

Bid Submitted By: Company _____________________________________ Rep. Name __________________________

Formal Bid Request FBR 1691-25 20

Review of bid specification sheets will focus on the compliance column with deviations noting where specifications exceed minimum requirements ONLY. Compliance deviations that do not meet or exceed the minimum requests will not be accepted.

NOTE : All bidders shall respond to each category below. Any 'no' responses or deviations shall be explained in the space provided. If it complies, put a check mark in the appropriate box.

SPECIFICATION COMPLIES IF NO: DEVIATES

AS NOTED

ITEM 8. 27”x3’x1’ Concrete solid wall riser

A. 4000 PSI Minimum Compressive Strength Concrete

B. ASTM A615 Grade 60 reinforcing steel

C. Meets ASTM C913 standards

D. Meets NCDOT Standard Drawing 840.45 and 840.46

E. Meets NCDOT Standard 1077

F. Meets City of Asheville Standard & Specification Section 8B.03: Structure Materials All storm drainage structures such as manholes, inlets, junction boxes, catch basins, endwalls and headwalls shall be constructed of solid brick, solid block, or precast concrete meeting NCDOT standards. Any structure with a depth greater than 4 feet shall have steps installed. All hoods, frames, and grates shall be domestically produced cast iron or steel and approved by NCDOT.

G. Meets City of Asheville Standard Detail 8.03 and 8.03A

H. NCDOT Certified/Stamped/Approved with inspection paperwork provided upon delivery

I. From sources on NCDOT’s Approved Producer / Supplier List for Precast Concrete

J. Advance Delivery Notification: Vendor must call 24 hours in advance to schedule a mutually agreeable delivery time. Hours are Monday - Thursday 7:00am - 3:30pm. Note: The City will not pay overtime for late deliveries. Deliveries must be unloaded and inspected prior to 3:30pm, any overtime after that will be charged

Bid Submitted By: Company _____________________________________ Rep. Name __________________________

Formal Bid Request FBR 1691-25 21

Review of bid specification sheets will focus on the compliance column with deviations noting where specifications exceed minimum requirements ONLY. Compliance deviations that do not meet or exceed the minimum requests will not be accepted.

NOTE : All bidders shall respond to each category below. Any 'no' responses or deviations shall be explained in the space provided. If it complies, put a check mark in the appropriate box.

SPECIFICATION COMPLIES IF NO: DEVIATES

AS NOTED

ITEM 9. 27”x3’x2’ Concrete solid wall riser

A. 4000 PSI Minimum Compressive Strength Concrete

B. ASTM A615 Grade 60 reinforcing steel

C. Meets ASTM C913 standards

D. Meets NCDOT Standard Drawing 840.45 and 840.46

E. Meets NCDOT Standard 1077

F. Meets City of Asheville Standard & Specification Section 8B.03: Structure Materials All storm drainage structures such as manholes, inlets, junction boxes, catch basins, endwalls and headwalls shall be constructed of solid brick, solid block, or precast concrete meeting NCDOT standards. Any structure with a depth greater than 4 feet shall have steps installed. All hoods, frames, and grates shall be domestically produced cast iron or steel and approved by NCDOT.

G. Meets City of Asheville Standard Detail 8.03 and 8.03A

H. NCDOT Certified/Stamped/Approved with inspection paperwork provided upon delivery

I. From sources on NCDOT’s Approved Producer / Supplier List for Precast Concrete

J. Advance Delivery Notification: Vendor must call 24 hours in advance to schedule a mutually agreeable delivery time. Hours are Monday - Thursday 7:00am - 3:30pm. Note: The City will not pay overtime for late deliveries. Deliveries must be unloaded and inspected prior to 3:30pm, any overtime after that will be charged

Bid Submitted By: Company _____________________________________ Rep. Name __________________________

Formal Bid Request FBR 1691-25 22

Review of bid specification sheets will focus on the compliance column with deviations noting where specifications exceed minimum requirements ONLY. Compliance deviations that do not meet or exceed the minimum requests will not be accepted.

NOTE : All bidders shall respond to each category below. Any 'no' responses or deviations shall be explained in the space provided. If it complies, put a check mark in the appropriate box.

SPECIFICATION COMPLIES IF NO: DEVIATES

AS NOTED

ITEM 10. 27”x3’x3’ Concrete solid wall riser

A. 4000 PSI Minimum Compressive Strength Concrete

B. ASTM A615 Grade 60 reinforcing steel

C. Meets ASTM C913 standards

D. Meets NCDOT Standard Drawing 840.45 and 840.46

E. Meets NCDOT Standard 1077

F. Meets City of Asheville Standard & Specification Section 8B.03: Structure Materials All storm drainage structures such as manholes, inlets, junction boxes, catch basins, endwalls and headwalls shall be constructed of solid brick, solid block, or precast concrete meeting NCDOT standards. Any structure with a depth greater than 4 feet shall have steps installed. All hoods, frames, and grates shall be domestically produced cast iron or steel and approved by NCDOT.

G. Meets City of Asheville Standard Detail 8.03 and 8.03A

H. NCDOT Certified/Stamped/Approved with inspection paperwork provided upon delivery

I. From sources on NCDOT’s Approved Producer / Supplier List for Precast Concrete

J. Advance Delivery Notification: Vendor must call 24 hours in advance to schedule a mutually agreeable delivery time. Hours are Monday - Thursday 7:00am - 3:30pm. Note: The City will not pay overtime for late deliveries. Deliveries must be unloaded and inspected prior to 3:30pm, any overtime after that will be charged

Bid Submitted By: Company _____________________________________ Rep. Name __________________________

Formal Bid Request FBR 1691-25 23

Review of bid specification sheets will focus on the compliance column with deviations noting where specifications exceed minimum requirements ONLY. Compliance deviations that do not meet or exceed the minimum requests will not be accepted.

NOTE : All bidders shall respond to each category below. Any 'no' responses or deviations shall be explained in the space provided. If it complies, put a check mark in the appropriate box.

SPECIFICATION COMPLIES IF NO: DEVIATES

AS NOTED

ITEM 11. 27”x3’x3’ Concrete riser with waffle knockouts

A. 4000 PSI Minimum Compressive Strength Concrete

B. ASTM A615 Grade 60 reinforcing steel

C. Meets ASTM C913 standards

D. Meets NCDOT Standard Drawing 840.45 and 840.46

E. Meets NCDOT Standard 1077

F. Meets City of Asheville Standard & Specification Section 8B.03: Structure Materials All storm drainage structures such as manholes, inlets, junction boxes, catch basins, endwalls and headwalls shall be constructed of solid brick, solid block, or precast concrete meeting NCDOT standards. Any structure with a depth greater than 4 feet shall have steps installed. All hoods, frames, and grates shall be domestically produced cast iron or steel and approved by NCDOT.

G. Meets City of Asheville Standard Detail 8.03 and 8.03A

H. NCDOT Certified/Stamped/Approved with inspection paperwork provided upon delivery

I. From sources on NCDOT’s Approved Producer / Supplier List for Precast Concrete

J. Advance Delivery Notification: Vendor must call 24 hours in advance to schedule a mutually agreeable delivery time. Hours are Monday - Thursday 7:00am - 3:30pm. Note: The City will not pay overtime for late deliveries. Deliveries must be unloaded and inspected prior to 3:30pm, any overtime after that will be charged

Bid Submitted By: Company _____________________________________ Rep. Name __________________________

Formal Bid Request FBR 1691-25 24

Review of bid specification sheets will focus on the compliance column with deviations noting where specifications exceed minimum requirements ONLY. Compliance deviations that do not meet or exceed the minimum requests will not be accepted.

NOTE : All bidders shall respond to each category below. Any 'no' responses or deviations shall be explained in the space provided. If it complies, put a check mark in the appropriate box.

SPECIFICATION COMPLIES IF NO: DEVIATES

AS NOTED

ITEM 12. 3’x3’x6” Concrete solid wall riser

A. 4000 PSI Minimum Compressive Strength Concrete

B. ASTM A615 Grade 60 reinforcing steel

C. Meets ASTM C913 standards

D. Meets NCDOT Standard Drawing 840.45 and 840.46

E. Meets NCDOT Standard 1077

F. Meets City of Asheville Standard & Specification Section 8B.03: Structure Materials All storm drainage structures such as manholes, inlets, junction boxes, catch basins, endwalls and headwalls shall be constructed of solid brick, solid block, or precast concrete meeting NCDOT standards. Any structure with a depth greater than 4 feet shall have steps installed. All hoods, frames, and grates shall be domestically produced cast iron or steel and approved by NCDOT.

G. Meets City of Asheville Standard Detail 8.03 and 8.03A

H. NCDOT Certified/Stamped/Approved with inspection paperwork provided upon delivery

I. From sources on NCDOT’s Approved Producer / Supplier List for Precast Concrete

J. Advance Delivery Notification: Vendor must call 24 hours in advance to schedule a mutually agreeable delivery time. Hours are Monday - Thursday 7:00am - 3:30pm. Note: The City will not pay overtime for late deliveries. Deliveries must be unloaded and inspected prior to 3:30pm, any overtime after that will be charged

Bid Submitted By: Company _____________________________________ Rep. Name __________________________

Formal Bid Request FBR 1691-25 25

Review of bid specification sheets will focus on the compliance column with deviations noting where specifications exceed minimum requirements ONLY. Compliance deviations that do not meet or exceed the minimum requests will not be accepted.

NOTE : All bidders shall respond to each category below. Any 'no' responses or deviations shall be explained in the space provided. If it complies, put a check mark in the appropriate box.

SPECIFICATION COMPLIES IF NO: DEVIATES

AS NOTED

ITEM 13. 3’x3’x1’ Concrete solid wall riser

A. 4000 PSI Minimum Compressive Strength Concrete

B. ASTM A615 Grade 60 reinforcing steel

C. Meets ASTM C913 standards

D. Meets NCDOT Standard Drawing 840.45 and 840.46

E. Meets NCDOT Standard 1077

F. Meets City of Asheville Standard & Specification Section 8B.03: Structure Materials All storm drainage structures such as manholes, inlets, junction boxes, catch basins, endwalls and headwalls shall be constructed of solid brick, solid block, or precast concrete meeting NCDOT standards. Any structure with a depth greater than 4 feet shall have steps installed. All hoods, frames, and grates shall be domestically produced cast iron or steel and approved by NCDOT.

G. Meets City of Asheville Standard Detail 8.03 and 8.03A

H. NCDOT Certified/Stamped/Approved with inspection paperwork provided upon delivery

I. From sources on NCDOT’s Approved Producer / Supplier List for Precast Concrete

J. Advance Delivery Notification: Vendor must call 24 hours in advance to schedule a mutually agreeable delivery time. Hours are Monday - Thursday 7:00am - 3:30pm. Note: The City will not pay overtime for late deliveries. Deliveries must be unloaded and inspected prior to 3:30pm, any overtime after that will be charged

Bid Submitted By: Company _____________________________________ Rep. Name __________________________

Formal Bid Request FBR 1691-25 26

Review of bid specification sheets will focus on the compliance column with deviations noting where specifications exceed minimum requirements ONLY. Compliance deviations that do not meet or exceed the minimum requests will not be accepted.

NOTE : All bidders shall respond to each category below. Any 'no' responses or deviations shall be explained in the space provided. If it complies, put a check mark in the appropriate box.

SPECIFICATION COMPLIES IF NO: DEVIATES

AS NOTED

ITEM 14. 3’x3’x2’ Concrete solid wall riser

A. 4000 PSI Minimum Compressive Strength Concrete

B. ASTM A615 Grade 60 reinforcing steel

C. Meets ASTM C913 standards

D. Meets NCDOT Standard Drawing 840.45 and 840.46

E. Meets NCDOT Standard 1077

F. Meets City of Asheville Standard & Specification Section 8B.03: Structure Materials All storm drainage structures such as manholes, inlets, junction boxes, catch basins, endwalls and headwalls shall be constructed of solid brick, solid block, or precast concrete meeting NCDOT standards. Any structure with a depth greater than 4 feet shall have steps installed. All hoods, frames, and grates shall be domestically produced cast iron or steel and approved by NCDOT.

G. Meets City of Asheville Standard Detail 8.03 and 8.03A

H. NCDOT Certified/Stamped/Approved with inspection paperwork provided upon delivery

I. From sources on NCDOT’s Approved Producer / Supplier List for Precast Concrete

J. Advance Delivery Notification: Vendor must call 24 hours in advance to schedule a mutually agreeable delivery time. Hours are Monday - Thursday 7:00am - 3:30pm. Note: The City will not pay overtime for late deliveries. Deliveries must be unloaded and inspected prior to 3:30pm, any overtime after that will be charged

Bid Submitted By: Company _____________________________________ Rep. Name __________________________

Formal Bid Request FBR 1691-25 27

Review of bid specification sheets will focus on the compliance column with deviations noting where specifications exceed minimum requirements ONLY. Compliance deviations that do not meet or exceed the minimum requests will not be accepted.

NOTE : All bidders shall respond to each category below. Any 'no' responses or deviations shall be explained in the space provided. If it complies, put a check mark in the appropriate box.

SPECIFICATION COMPLIES IF NO: DEVIATES

AS NOTED

ITEM 15. 3’x3’x3’ Concrete solid wall riser

A. 4000 PSI Minimum Compressive Strength Concrete

B. ASTM A615 Grade 60 reinforcing steel

C. Meets ASTM C913 standards

D. Meets NCDOT Standard Drawing 840.45 and 840.46

E. Meets NCDOT Standard 1077

F. Meets City of Asheville Standard & Specification Section 8B.03: Structure Materials All storm drainage structures such as manholes, inlets, junction boxes, catch basins, endwalls and headwalls shall be constructed of solid brick, solid block, or precast concrete meeting NCDOT standards. Any structure with a depth greater than 4 feet shall have steps installed. All hoods, frames, and grates shall be domestically produced cast iron or steel and approved by NCDOT.

G. Meets City of Asheville Standard Detail 8.03 and 8.03A

H. NCDOT Certified/Stamped/Approved with inspection paperwork provided upon delivery

I. From sources on NCDOT’s Approved Producer / Supplier List for Precast Concrete

J. Advance Delivery Notification: Vendor must call 24 hours in advance to schedule a mutually agreeable delivery time. Hours are Monday - Thursday 7:00am - 3:30pm. Note: The City will not pay overtime for late deliveries. Deliveries must be unloaded and inspected prior to 3:30pm, any overtime after that will be charged

Bid Submitted By: Company _____________________________________ Rep. Name __________________________

Formal Bid Request FBR 1691-25 28

Review of bid specification sheets will focus on the compliance column with deviations noting where specifications exceed minimum requirements ONLY. Compliance deviations that do not meet or exceed the minimum requests will not be accepted.

NOTE : All bidders shall respond to each category below. Any 'no' responses or deviations shall be explained in the space provided. If it complies, put a check mark in the appropriate box.

SPECIFICATION COMPLIES IF NO: DEVIATES

AS NOTED

ITEM 16. 3’x3’x3’ Concrete riser with waffle knockouts

A. 4000 PSI Minimum Compressive Strength Concrete

B. ASTM A615 Grade 60 reinforcing steel

C. Meets ASTM C913 standards

D. Meets NCDOT Standard Drawing 840.45 and 840.46

E. Meets NCDOT Standard 1077

F. Meets City of Asheville Standard & Specification Section 8B.03: Structure Materials All storm drainage structures such as manholes, inlets, junction boxes, catch basins, endwalls and headwalls shall be constructed of solid brick, solid block, or precast concrete meeting NCDOT standards. Any structure with a depth greater than 4 feet shall have steps installed. All hoods, frames, and grates shall be domestically produced cast iron or steel and approved by NCDOT.

G. Meets City of Asheville Standard Detail 8.03 and 8.03A

H. NCDOT Certified/Stamped/Approved with inspection paperwork provided upon delivery

I. From sources on NCDOT’s Approved Producer / Supplier List for Precast Concrete

J. Advance Delivery Notification: Vendor must call 24 hours in advance to schedule a mutually agreeable delivery time. Hours are Monday - Thursday 7:00am - 3:30pm. Note: The City will not pay overtime for late deliveries. Deliveries must be unloaded and inspected prior to 3:30pm, any overtime after that will be charged

Bid Submitted By: Company _____________________________________ Rep. Name __________________________

Formal Bid Request FBR 1691-25 29

Review of bid specification sheets will focus on the compliance column with deviations noting where specifications exceed minimum requirements ONLY. Compliance deviations that do not meet or exceed the minimum requests will not be accepted.

NOTE : All bidders shall respond to each category below. Any 'no' responses or deviations shall be explained in the space provided. If it complies, put a check mark in the appropriate box.

SPECIFICATION COMPLIES IF NO: DEVIATES

AS NOTED

ITEM 17. 4’x4’x6” Concrete solid wall riser

A. 4000 PSI Minimum Compressive Strength Concrete

B. ASTM A615 Grade 60 reinforcing steel

C. Meets ASTM C913 standards

D. Meets NCDOT Standard Drawing 840.45 and 840.46

E. Meets NCDOT Standard 1077

F. Meets City of Asheville Standard & Specification Section 8B.03: Structure Materials All storm drainage structures such as manholes, inlets, junction boxes, catch basins, endwalls and headwalls shall be constructed of solid brick, solid block, or precast concrete meeting NCDOT standards. Any structure with a depth greater than 4 feet shall have steps installed. All hoods, frames, and grates shall be domestically produced cast iron or steel and approved by NCDOT.

G. Meets City of Asheville Standard Detail 8.03 and 8.03A

H. NCDOT Certified/Stamped/Approved with inspection paperwork provided upon delivery

I. From sources on NCDOT’s Approved Producer / Supplier List for Precast Concrete

J. Advance Delivery Notification: Vendor must call 24 hours in advance to schedule a mutually agreeable delivery time. Hours are Monday - Thursday 7:00am - 3:30pm. Note: The City will not pay overtime for late deliveries. Deliveries must be unloaded and inspected prior to 3:30pm, any overtime after that will be charged

Bid Submitted By: Company _____________________________________ Rep. Name __________________________

Formal Bid Request FBR 1691-25 30

Review of bid specification sheets will focus on the compliance column with deviations noting where specifications exceed minimum requirements ONLY. Compliance deviations that do not meet or exceed the minimum requests will not be accepted.

NOTE : All bidders shall respond to each category below. Any 'no' responses or deviations shall be explained in the space provided. If it complies, put a check mark in the appropriate box.

SPECIFICATION COMPLIES IF NO: DEVIATES

AS NOTED

ITEM 18. 4’x4’x1’ Concrete solid wall riser

A. 4000 PSI Minimum Compressive Strength Concrete

B. ASTM A615 Grade 60 reinforcing steel

C. Meets ASTM C913 standards

D. Meets NCDOT Standard Drawing 840.45 and 840.46

E. Meets NCDOT Standard 1077

F. Meets City of Asheville Standard & Specification Section 8B.03: Structure Materials All storm drainage structures such as manholes, inlets, junction boxes, catch basins, endwalls and headwalls shall be constructed of solid brick, solid block, or precast concrete meeting NCDOT standards. Any structure with a depth greater than 4 feet shall have steps installed. All hoods, frames, and grates shall be domestically produced cast iron or steel and approved by NCDOT.

G. Meets City of Asheville Standard Detail 8.03 and 8.03A

H. NCDOT Certified/Stamped/Approved with inspection paperwork provided upon delivery

I. From sources on NCDOT’s Approved Producer / Supplier List for Precast Concrete

J. Advance Delivery Notification: Vendor must call 24 hours in advance to schedule a mutually agreeable delivery time. Hours are Monday - Thursday 7:00am - 3:30pm. Note: The City will not pay overtime for late deliveries. Deliveries must be unloaded and inspected prior to 3:30pm, any overtime after that will be charged

Bid Submitted By: Company _____________________________________ Rep. Name __________________________

Formal Bid Request FBR 1691-25 31

Review of bid specification sheets will focus on the compliance column with deviations noting where specifications exceed minimum requirements ONLY. Compliance deviations that do not meet or exceed the minimum requests will not be accepted.

NOTE : All bidders shall respond to each category below. Any 'no' responses or deviations shall be explained in the space provided. If it complies, put a check mark in the appropriate box.

SPECIFICATION COMPLIES IF NO: DEVIATES

AS NOTED

ITEM 19. 4’x4’x2’ Concrete solid wall riser

A. 4000 PSI Minimum Compressive Strength Concrete

B. ASTM A615 Grade 60 reinforcing steel

C. Meets ASTM C913 standards

D. Meets NCDOT Standard Drawing 840.45 and 840.46

E. Meets NCDOT Standard 1077

F. Meets City of Asheville Standard & Specification Section 8B.03: Structure Materials All storm drainage structures such as manholes, inlets, junction boxes, catch basins, endwalls and headwalls shall be constructed of solid brick, solid block, or precast concrete meeting NCDOT standards. Any structure with a depth greater than 4 feet shall have steps installed. All hoods, frames, and grates shall be domestically produced cast iron or steel and approved by NCDOT.

G. Meets City of Asheville Standard Detail 8.03 and 8.03A

H. NCDOT Certified/Stamped/Approved with inspection paperwork provided upon delivery

I. From sources on NCDOT’s Approved Producer / Supplier List for Precast Concrete

J. Advance Delivery Notification: Vendor must call 24 hours in advance to schedule a mutually agreeable delivery time. Hours are Monday - Thursday 7:00am - 3:30pm. Note: The City will not pay overtime for late deliveries. Deliveries must be unloaded and inspected prior to 3:30pm, any overtime after that will be charged

Bid Submitted By: Company _____________________________________ Rep. Name __________________________

Formal Bid Request FBR 1691-25 32

Review of bid specification sheets will focus on the compliance column with deviations noting where specifications exceed minimum requirements ONLY. Compliance deviations that do not meet or exceed the minimum requests will not be accepted.

NOTE : All bidders shall respond to each category below. Any 'no' responses or deviations shall be explained in the space provided. If it complies, put a check mark in the appropriate box.

SPECIFICATION COMPLIES IF NO: DEVIATES

AS NOTED

ITEM 20. 4’x4’x3’ Concrete solid wall riser

A. 4000 PSI Minimum Compressive Strength Concrete

B. ASTM A615 Grade 60 reinforcing steel

C. Meets ASTM C913 standards

D. Meets NCDOT Standard Drawing 840.45 and 840.46

E. Meets NCDOT Standard 1077

F. Meets City of Asheville Standard & Specification Section 8B.03: Structure Materials All storm drainage structures such as manholes, inlets, junction boxes, catch basins, endwalls and headwalls shall be constructed of solid brick, solid block, or precast concrete meeting NCDOT standards. Any structure with a depth greater than 4 feet shall have steps installed. All hoods, frames, and grates shall be domestically produced cast iron or steel and approved by NCDOT.

G. Meets City of Asheville Standard Detail 8.03 and 8.03A

H. NCDOT Certified/Stamped/Approved with inspection paperwork provided upon delivery

I. From sources on NCDOT’s Approved Producer / Supplier List for Precast Concrete

J. Advance Delivery Notification: Vendor must call 24 hours in advance to schedule a mutually agreeable delivery time. Hours are Monday - Thursday 7:00am - 3:30pm. Note: The City will not pay overtime for late deliveries. Deliveries must be unloaded and inspected prior to 3:30pm, any overtime after that will be charged

Bid Submitted By: Company _____________________________________ Rep. Name __________________________

Formal Bid Request FBR 1691-25 33

Review of bid specification sheets will focus on the compliance column with deviations noting where specifications exceed minimum requirements ONLY. Compliance deviations that do not meet or exceed the minimum requests will not be accepted.

NOTE : All bidders shall respond to each category below. Any 'no' responses or deviations shall be explained in the space provided. If it complies, put a check mark in the appropriate box.

SPECIFICATION COMPLIES IF NO: DEVIATES

AS NOTED

ITEM 21. 4’x4’x4’ Concrete riser with waffle knockouts

A. 4000 PSI Minimum Compressive Strength Concrete

B. ASTM A615 Grade 60 reinforcing steel

C. Meets ASTM C913 standards

D. Meets NCDOT Standard Drawing 840.45 and 840.46

E. Meets NCDOT Standard 1077

F. Meets City of Asheville Standard & Specification Section 8B.03: Structure Materials All storm drainage structures such as manholes, inlets, junction boxes, catch basins, endwalls and headwalls shall be constructed of solid brick, solid block, or precast concrete meeting NCDOT standards. Any structure with a depth greater than 4 feet shall have steps installed. All hoods, frames, and grates shall be domestically produced cast iron or steel and approved by NCDOT.

G. Meets City of Asheville Standard Detail 8.03 and 8.03A

H. NCDOT Certified/Stamped/Approved with inspection paperwork provided upon delivery

I. From sources on NCDOT’s Approved Producer / Supplier List for Precast Concrete

J. Advance Delivery Notification: Vendor must call 24 hours in advance to schedule a mutually agreeable delivery time. Hours are Monday - Thursday 7:00am - 3:30pm. Note: The City will not pay overtime for late deliveries. Deliveries must be unloaded and inspected prior to 3:30pm, any overtime after that will be charged

Bid Submitted By: Company _____________________________________ Rep. Name __________________________

Formal Bid Request FBR 1691-25 34

Drawings Associated with Items 7 - 21

NCDOT 840.45.pdf

Bid Submitted By: Company _____________________________________ Rep. Name __________________________ https://drive.google.com/file/d/11O1tlWyI31W-M2yeQKyPdGIFCo9RIBgf/view?usp=drive_link

Formal Bid Request FBR 1691-25 35

Bid Submitted By: Company _____________________________________ Rep. Name __________________________

Formal Bid Request FBR 1691-25 36

NCDOT 840.46

Bid Submitted By: Company _____________________________________ Rep. Name __________________________ https://drive.google.com/file/d/1jTA0-G4EWKa_-6fAANIjgfJSZ5OtIv9u/view?usp=drive_link

Formal Bid Request FBR 1691-25 37

Bid Submitted By: Company _____________________________________ Rep. Name __________________________

Formal Bid Request FBR 1691-25 38

Bid Submitted By: Company _____________________________________ Rep. Name __________________________

Formal Bid Request FBR 1691-25 39

Review of bid specification sheets will focus on the compliance column with deviations noting where specifications exceed minimum requirements ONLY. Compliance deviations that do not meet or exceed the minimum requests will not be accepted.

NOTE : All bidders shall respond to each category below. Any 'no' responses or deviations shall be explained in the space provided. If it complies, put a check mark in the appropriate box.

SPECIFICATION COMPLIES IF NO: DEVIATES

AS NOTED

ITEM 22. 3’x3’x6” Lids with 24” Hole in center

A. 4000 PSI Minimum Compressive Strength Concrete

B. ASTM A615 Grade 60 reinforcing steel

C. Meets ASTM C913 standards

D. Meets NCDOT Standard 10.44

E. Meets NCDOT Standard Drawing 840.04

F. Meets COA Standard Detail 8.01 and 8.03

G. NCDOT Certified/Stamped/Approved with inspection paperwork provided upon delivery

H. From sources participating in NCDOT’s Precast Concrete QC/QA Program

I. Advance Delivery Notification: Vendor must call 24 hours in advance to schedule a mutually agreeable delivery time. Hours are Monday - Thursday 7:00am - 3:30pm. Note: The City will not pay overtime for late deliveries. Deliveries must be unloaded and inspected prior to 3:30pm, any overtime after that will be charged

Bid…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .