About this file
This document is a site plan for the Wyatt Swimming Pool project, prepared by MetroCorp Development Enterprises, Inc. for the City of College Park, located at 3620 Godby Road, College Park, GA 30337. The site plan, dated 09/07/2023, provides a detailed aerial view of the recreation center's outdoor pool facility, which includes a main pool and a splash pool. The plan indicates specific architectural and infrastructural details, such as existing light pole heights (28' typical), mounted light heights (6'-8'), and a note about drain frames and grates that need to be reinstalled or lowered to be flush with the swimming pool floor.
The site plan reveals the pool complex's layout within the Wyatt Recreation Center, showing the main pool and splash pool positioned adjacent to a green-roofed building, with surrounding parking areas and landscaped grounds. The plan includes an expansion joint with tile lining and provides precise measurements and spatial relationships. While the document does not contain specific pricing, contract terms, or funding details, it serves as a critical design and planning tool for the pool renovation or maintenance project, offering a comprehensive overhead view of the facility's current configuration and potential improvement areas.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| RFP _ 26_16 OUTDOOR POOL REHABILITATION.pdf | ||
| POOL ATTACHEMENT 3.pdf | ||
| POOL ATTACHEMNT.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
EXISTING LIGHT POLE
HT: 28'
TYP. 4
EXISTING MOUNTED LIGHTS
HT.:7'
EXISTING MOUNTED LIGHTS
HT.:7'
EXISTING MOUNTED LIGHTS
HT.:6' -8"
Drain frames and grates need to be reinstalled/lowered to be flush/level with the swimming pool floor
EXPANSION JT. W/ TILE LINING
M
ET
RO
CO
RP
DE
VE
LO
PM
EN
T
EN
TE
RP
RI
SE
S, IN
C.
C :\U
SE
R
S\
PC
\D O
C U
M
EN
TS
\M
D E
P R
O
JE
C
TS
3\ C
O
LL
EG
E
PA
R
K
SW
IM
M
IN
G
PO
O
LS
.D
W G
6/
/2
W
YA
TT
S
W
IM
M
IN
G P
O O
L C
IT
Y
O F
C O
LL
EG
E
PA
R K
09/07/2023
3/32"=1'-0"
23CP_SWPL
SI
TE
P
LA
N
S1
1.1Locations: Wyatt Recreation Center Outdoor Pool 3620 Godby Road, College, Park 30337
MAIN
POOL
SPLASH
POOL
AutoCAD SHX Text Sheet
AutoCAD SHX Text Scale:
AutoCAD SHX Text Project No.:
AutoCAD SHX Text Date:
AutoCAD SHX Text Revision/Issue
AutoCAD SHX Text No.
AutoCAD SHX Text Date
AutoCAD SHX Text Technician:
AutoCAD SHX Text Checked by:
AutoCAD SHX Text Designer:
AutoCAD SHX Text (404)695-7902 www.metrocorpde.com
AutoCAD SHX Text
8491 HOSPITAL DRIVE, STE. 101,
AutoCAD SHX Text
DOUGLASVILLE, GEORGIA 30135
AutoCAD SHX Text THE DRAWING IS COPYRIGHTED. THE ORIGINAL DRAWING WAS PRODUCED AND IS ON RECORD IN THE OFFICES OF THIS FIRM. ANY UNAUTHORIZED USE, MODIFICATION, AND/OR REPRODUCTION OF THIS DRAWING,IN PART OR WHOLE, IS HEREBY PROHIBITED UNLESS AUTHORIZED IN WRITING BY METROCORP DEVELOPMENT ENTERPRISES, INC..
| Sheets and Views |
| WYATT POOL |
File details come from the government source that posted it. Updated .