PLANS Tucker 1st Ave Compactor _ Final 6_16_.pdf
PDF 17 MB Posted
- Solicitation number
- PE-66956-NONST-2026-000000051
- Issued by
- Dekalb County, Georgia
About this file
This is a construction plan document for the City of Tucker, Georgia, detailing the site construction of a sanitary compactor facility on a permanent easement at 4239 1st Avenue, Tucker, GA 30084. The project requires the contractor to provide all materials, equipment, shipping and delivery, installation, and labor to complete construction according to specifications and contract terms under the direction of the City's Public Works director. The plans include detailed architectural and site layout drawings showing the compactor facility footprint, access points, utility connections, and site grading requirements. The document specifies construction standards and technical requirements necessary for the facility's proper installation and operation, with dimensions and specifications clearly marked for contractor reference during bidding and construction phases.
The plans establish the technical baseline for ITB 2025-019, enabling contractors to develop accurate cost estimates and project timelines. Bidders must review the plans in conjunction with the contract's scope of work to ensure complete understanding of all requirements, site conditions, and construction specifications. The document serves as a binding reference for all construction activities and serves as the basis for contract performance evaluation and payment processing. Contractors should conduct thorough site inspections and review all plan details prior to submitting bids to ensure accurate pricing and feasibility assessments.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| ITB 2025_019 First Avenue Sanitary Compact Fa.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CONTACTS
TUCKER, DEKALB COUNTY, GEORGIA
1S T
AV
E
C O
M
PA
C
TO
R F
AC
IL
IT
Y
C
IT
Y O
F
TU
C
KE
R
C0.01
VICINITY MAP
NOT TO SCALE
DESIGN PROFESSIONAL BARGE DESIGN SOLUTIONS
2839 PACES FERRY ROAD SE//SUITE 850
ATLANTA, GEORGIA 30339
PHONE (770) 282-4958
CONTACT: BRIAN DERISO
CITY OF TUCKER
Know what'sbelow Callbefore you dig.
www.call811.com
Copyright 2023, Barge Design Solutions, Inc. ALL RIGHTS RESERVED
U
SE
R :J
AC
O
U
SI
N
EA
U
FI
LE
:F
:\3 8\
8\
7\
_C
AD
\C
IV
L\ D ra w in g\
PL
O
T\
4_ C
O
VE
R .d w g
PL
O
TT
ED
:6 /1
6/
SA
VE
D
:5 /1
9/
2839 PACES FERRY ROAD SE//SUITE 850
ATLANTA, GEORGIA 30339
Phone (770) 282-4958
OWNER CITY OF TUCKER
1975 LAKESIDE PKWY, SUITE 350
TUCKER, GA 30084
470-603-1279
CONTACT: MICAH SEIBEL ASSISTANT CITY MANAGER
TU
C
KE
R
, D
EK
AL
B
C O
U N
TY
G
EO
R
G
IA
N
SITE
INDEX OF DRAWINGS
DESCRIPTIONSHEET NO.
C0.0 COVER SHEET
C0.10 GENERAL NOTES
C0.21 EXISTING CONDITIONS
C0.41 DEMOLITION AND TREE PROTECTION PLAN
C1.01 SITE LAYOUT PLAN
C2.00 GRADING AND DRAINAGE PLAN
C3.01 SITE UTILITY PLAN
C4.01 SEWER LATERAL PROFILE
EC1.01 EROSION CONTROL PLAN
C7.01 SITE DETAILS
C7.02 SITE DETAILS
C7.03 SITE DETAILS
E0.01 ELECTRICAL LEGEND
ES1.01 ELECTRICAL SITE PLAN
E5.01 ELECTRICAL DETAILS
S0.01 GENERAL NOTES AND SCHEDULES
S1.01 FOUNDATION PLAN AND SECTIONS
S3.01 STRUCTURAL DETAILS
1ST AVENUE COMPACTOR FACILITY
APRIL 2025
PROJECT No. 3808807
SHEET
NONE OF THE DISTURBED AREA IS WITHIN THE FEMA 100-YR FLOOD ZONE.
GENERAL NOTES:
1. CONTRACTOR MUST FIELD VERIFY EXISTING CONDITIONS PRIOR TO AND DURING
CONSTRUCTION, AND VERIFY DEPTH OF EXISTING UTILITY LINES PRIOR TO LAND
DISTURBANCE.
2. CONTRACTOR TO ABIDE BY ALL STATE AND LOCAL CODES AND ORDINANCES PRIOR
TO AND DURING CONSTRUCTION, INCLUDING INSPECTIONS.
3. CONTRACTOR TO ERECT AND MAINTAIN ALL APPROPRIATE BARRICADES, SIGNAGE,
AND WARNINGS TO PROTECT THE SITE DURING DEMOLITION AND CONSTRUCTION.
4. ALL TREE PROTECTION AREAS TO BE PROTECTED FROM SEDIMENTATION.
5. CONTRACTOR SHALL INSTALL ALL TREE PROTECTION FENCING AND ALL EROSION
CONTROL MEASURES PRIOR TO THE START OF LAND DISTURBANCE ACTIVITIES OR
DEMOLITION, AND MAINTAIN UNTIL FINAL LANDSCAPING IS COMPLETE.
6. ALL TREE PROTECTION FENCING TO BE INSPECTED DAILY, AND REPAIRED AND
REPLACED AS NEEDED.
7. NO PARKING, STORAGE OR OTHER CONSTRUCTION ACTIVITIES ARE TO OCCUR
WITHIN TREE PROTECTION AREAS.
8. CONTRACTOR TO NOTIFY OWNER IMMEDIATELY IF ANY ITEM EXISTING ON SITE IS
NOT SHOWN ON THESE PLANS (E.G. UTILITY/DRAINAGE LINES).
9. ANY UNDERGROUND UTILITY THAT IS BROKEN OR DISRUPTED THAT IS A NOT PART
OF A SCHEDULED OUTAGE SHALL BE REPAIRED AS QUICKLY AS POSSIBLE AT
CONTRACTOR'S EXPENSE.
10. CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS FOR THE PROTECTION
OF THE PUBLIC, INCLUDING BUT NOT LIMITED TO THE INSTALLATION OF LIGHTS,
BARRIERS, FLAGMEN, AND TEMPORARY DETOURS, ETC.
11. CONTRACTOR SHALL UTILIZE ALL PRACTICABLE MEASURES TO ENSURE THE
PREVENTION OF ENVIRONMENTAL IMPACTS ARE TAKEN BY ALL PERSONNEL
EMPLOYED IN THE WORK. IMPACTS INCLUDE BUT ARE NOT NECESSARILY LIMITED
TO NOISE, DUST, CHEMICAL SPILL, EROSION AND SEDIMENTATION, AND DAMAGE TO
EXISTING TREES AND PLANTS.
12. CONTRACTOR SHALL ENSURE POSITIVE DRAINAGE AWAY FROM STRUCTURES.
13. ALL SANITARY SEWER MATERIALS, INSTALLATION TECHNIQUES, AND TESTING
REQUIREMENTS TO CONFORM TO DEKALB COUNTY WATERSHED STANDARDS.
14. IT IS THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE INSPECTIONS WITH
DEKALB DEPARTMENT OF WATERSHED MANAGEMENT.
15. CONTRACTOR TO PROVIDE A TRAFFIC CONTROL PLAN CONFORMING TO THE
MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD) FOR CITY REVIEW
REGARDING WORK WITHIN THE 1ST AVENUE RIGHT OF WAY.
PROJECT AREA: 0.18 AC
DISTURBED AREA: 0.17 AC
04/22/2025
N/F
FA TUCKER LLC
PIN # 18 213 14 011
N/F
OUR GENERATIONS INC.
PIN # 18 213 14 028
N/F
ISLAND STYLE INVESTMENT LLC
PIN # 18 213 14 010
N/F
ROBERT H. BEASLEY
PIN # 18 213 14 004
N/F
KGEF LLC
PIN # 18 213 14 005
N/F
DAVID S. CARR
PIN # 18 213 14 006
N/F
CARRS PHARMACY INC.
PIN # 18 213 14 007
N/F
LTR INVESTMENTS INC.
PIN # 18 213 12 012
N/F
P AND B PROPERTIES LLC
PIN # 18 213 14 008
N/F
MONTREAL PARTNERS LLC
PIN # 18 213 14 008
(BURNETT & ASSOC.)
(TANDEM BANK)
(FURBUSTERS)
PROPERTY LINE
PROPERTY LINE
PROPERTY LINE
PROPERTY LINE
PROPERTY LINE
20' 40'
SCALE: 1 INCH = 20 FEET
10'20' 0'
1ST AVE
M
AI
N S
T 3808804
C0.21
TU
C
KE
R
, D
EK
AL
B
C O
U N
TY
, G
EO
R
G
IA
C
IT
Y O
F
TU
C
KE
R
EX
IS
TI
N
G C
O N
D
IT
IO
N
S
1S T
AV
E
C O
M
PA
C
TO
R F
AC
IL
IT
Y
EXISTING TRAIL
FILE NO.
C H
K.
D
R
D
AT
E D
ES
C
R
IP
TI
O
N R
EV
R
EV
IS
IO
N
IN
FO
R
M
AT
IO
N
Copyright 2024, Barge Design Solutions, Inc. ALL RIGHTS RESERVED
T he
C or ne rs
P kw y
Su ite
P ea ch tre e
C or ne rs
, G A
PH
O N
E (6
) 5
-9
U
SE
R :J
AC
O
U
SI
N
EA
U
FI
LE
:F
:\3 8\
8\
7\
_C
AD
\C
IV
L\ D ra w in g\
PL
O
T\
EX
C on di tio ns
.d w g
PL
O
TT
ED
:6 /1
6/
SA
VE
D
:4 /1
1/
JA
C
JA
C
-1
5-
D
EK
AL
B C
O U
N
TY
C O
M M
EN
TS
Know what'sbelow Callbefore you dig.
www.call811.com
Know what'sbelow Callbefore you dig.
www.call811.com
JA
C
JA
C
-1
3-
G
EO
R
G
IA
P O
W
ER
N O
TE
S
AN
D
C
AL
LO
U
TS
LEGEND
EXISTING CONTOUR
EX. SPOT ELEVATION (+1100)
EX. WATERLINE
OVERHEAD POWER LINE
UNDERGROUND POWER
EX. SEWER LINE
EX. GAS LINE
SUPPLEMENTAL SPOT ELEVATION (+1100)
EASEMENT
EXISTING TRAIL
EXISTING GRAVEL ROAD
NOTES:
1. SURVEY PROVIDED BY OWNER. EXISTING TRAIL SIDEWALK IMPROVEMENTS SHOWN
BASED ON PLANS. NO AS-BUILT SURVEY WAS COMPLETED AFTER SIDEWALK WAS
CONSTRUCTED.
2. SUPPLEMENTAL SPOT ELEVATIONS PROVIDED BY THE CITY SHOWN IN BLUE. TOP OF
EXISTING SEWER MANHOLE, ELEVATION 1102.08, AS IDENTIFIED IN PLAN, WAS USED AS
BENCHMARK. SURVEY DATE FEB 14, 2024.
3. TEMPORARY CONSTRUCTION EASEMENT GRANTED TO CITY OF TUCKER BY ISLAND
STYLE INVESTMENT, LLC.
4. PERMANENT EASEMENT GRANTED TO CITY OF TUCKER BY MONTREAL PARTNERS, LLC.
5. PERMANENT EASEMENT GRANTED TO CITY OF TUCKER BY P AND B PROPERTIES, LLC.
6. TEMPORARY CONSTRUCTION EASEMENT GRANTED TO CITY OF TUCKER BY 1619 HOSEA,
LLC.
7. CONTRACTOR SHALL VERIFY THE LOCATIONS AND INVERTS OF ALL EXISTING UTILITY
LINES AND STRUCTURES (INCLUDING STORM DRAINAGE PIPES AND STRUCTURES)
BEFORE THE COMMENCEMENT OF CONSTRUCTION.
SURVEY DATA PROVIDED BY CITY OF TUCKER.
BENCHMARK
(EX. MANHOLE,
TOP ELEV. 1102.08)
EXISTING 280 SF PERMANENT
EASEMENT (SEE NOTE 4)
EXISTING 259.8 SF PERMANENT
EASEMENT (SEE NOTE 5)
EXISTING 380.9 SF CONSTRUCTION
EASEMENT (SEE NOTE 6)
EXISTING 1825.1 SF TEMPORARY
CONSTRUCTION EASEMENT (SEE NOTE 3)
100' EXISTING RIGHT OF WAY
EXISTING R/W
EXISTING TRAIL
PIN # 18 213 14 011
N/F
OUR GENERATIONS INC.
PIN # 18 213 14 028
N/F
ISLAND STYLE INVESTMENT LLC
PIN # 18 213 14 010
N/F
ROBERT H. BEASLEY
PIN # 18 213 14 004
N/F
KGEF LLC
PIN # 18 213 14 005
N/F
DAVID S. CARR
PIN # 18 213 14 006
N/F
CARRS PHARMACY INC.
PIN # 18 213 14 007
N/F
LTR INVESTMENTS INC.
PIN # 18 213 12 012
N/F
PARIKH & PARIKH LLC
PIN # 18 213 12 010
N/F
P AND B PROPERTIES LLC
PIN # 18 213 14 008
N/F
MONTREAL PARTNERS LLC
PIN # 18 213 14 008
(BURNETT & ASSOC.)
(TANDEM BANK)
(FURBUSTERS)
PROPERTY LINE
PROPERTY LINE
PROPERTY LINE
PROPERTY LINE
PROPERTY LINE
SA
SA
SA
SA
SA
SA
20' 40'
SCALE: 1 INCH = 20 FEET
10'20' 0'
1ST AVE
3808804
C0.41
TU
C
KE
R
, D
EK
AL
B
C O
U N
TY
, G
EO
R
G
IA
C
IT
Y O
F
TU
C
KE
R
D
EM
O
LI
TI
O
N A
N D
T R
EE
P
R O
TE
C
TI
O
N P
LA
N
1S T
AV
E
C O
M
PA
C
TO
R F
AC
IL
IT
Y
FILE NO.
C H
K.
D
R
D
AT
E D
ES
C
R
IP
TI
O
N R
EV
R
EV
IS
IO
N
IN
FO
R
M
AT
IO
N
Copyright 2024, Barge Design Solutions, Inc. ALL RIGHTS RESERVED
T he
C or ne rs
P kw y
Su ite
P ea ch tre e
C or ne rs
, G A
N
E (6
) 5
-9
U
SE
R :J
AC
O
U
SI
N
EA
U
FI
LE
:F
:\3 8\
8\
7\
_C
AD
\C
IV
L\ D ra w in g\
PL
O
T\
D em o Pl an .d w g
PL
O
TT
ED
:6 /1
6/
SA
VE
D
:4 /1
4/
JA
C
JA
C
-1
5-
D
EK
AL
B C
O U
N
TY
C O
M M
EN
TS
Know what'sbelow Callbefore you dig.
www.call811.com
Know what'sbelow Callbefore you dig.
www.call811.com
JA
C
JA
C
-1
3-
G
EO
R
G
IA
P O
W
ER
N O
TE
S
AN
D
C
AL
LO
U
TS
SAW CUT CLEAN EDGE
SAW CUT
SAW CUT CLEAN EDGE
SAW CUT CLEAN EDGE
SAW CUT CLEAN EDGE
DEMOLITION NOTES
1. CONTRACTOR TO FIELD VERIFY LOCATIONS OF EXISTING UTILITIES
PRIOR TO START OF CONSTRUCTION.
2. CONTRACTOR TO PROVIDE SMOOTH, STRAIGHT SAW-CUT LINES
ALONG ALL AREAS OF CURB, PAVEMENT, TRAIL, SIDEWALK REMOVAL.
3. CONTRACTOR TO PROTECT EXISTING IMPROVEMENTS WITHIN
PROJECT AREA. ANY AREAS THAT BECOME DAMAGED DURING
CONSTRUCTION ARE THE RESPONSIBILITY OF THE CONTRACTOR TO
REPAIR.
4. CONTRACTOR TO DISPOSE DEMOLISHED MATERIAL OFFSITE IN
ACCORDANCE WITH ALL LEGAL REQUIREMENTS.
LEGEND
CURB AND GUTTER, PAVEMENT,
SIDEWALK REMOVAL
GRAVEL REMOVAL
DEMOLITION KEYNOTES
REMOVE EXISTING GRAVEL
REMOVE EXISTING CURB AND GUTTER AND
SIDEWALK RAMP
REMOVE PORTION OF EXISTING WALL REQ'D FOR
PROJECT CONSTRUCTION
REMOVE EXISTING CURB AND GUTTER AND
PAVEMENT
REMOVE EXISTING CONCRETE SIDEWALK
REMOVE EXISTING CURB AND GUTTER AND ISLAND
REMOVE EXISTING CONCRETE/DEBRIS IN PATH OF
PROPOSED SANITARY LATERAL AS REQ'D
SAWCUT & REMOVE EXISTING SIDEWALK
EXISTING TREES TO BE PROTECTED WITH TREE
PROTECTION FENCING (1/C0.41)
REMOVE EXISTING CURB AND PAVEMENT FOR
INSTALLATION OF CONDUIT
LEGEND
EXISTING CONTOUR
EX. SPOT ELEVATION (+1100)
EX. WATERLINE
OVERHEAD POWER LINE
EX. SEWER LINE
EX. GAS LINE
SUPPLEMENTAL EXISTING SPOT
ELEVATION (+1100)
EXISTING TRAIL
TREE PROTECTION FENCING
TREE PROTECTION NOTES
1. IF THERE ARE INCONSISTENCIES BETWEEN ANY ITEMS ON THESE PLANS THE
MORE STRICT INTERPRETATION OF THOSE REQUIREMENTS SHALL BE
FOLLOWED. PLEASE CONTACT CITY OF TUCKER PROJECT MANAGER FOR
ANY INTERPRETATION.
2. TREE SAVE FENCE AND SIGNAGE FOR ENTIRE SITE MUST BE INSTALLED,
INSPECTED AND APPROVED PRIOR TO INSTALLATION OF EROSION CONTROL
MEASURES. NO LAND DISTURBANCE OR DEMOLITION IS ALLOWED BEFORE
THIS INSPECTION AND APPROVAL HAS OCCURRED.
3. INSTALLATION OF THE TREE SAVE FENCE WILL INVOLVE NO TRENCHING.
4. ALL EXISTING TREES IDENTIFIED FOR PRESERVATION OR FOUND WITHIN
TREE SAVE AREAS MUST BE FULLY PROTECTED DURING ALL PHASES OF THE
PROJECT.
5. ALL ROOTS ENCOUNTERED 12" OR GREATER DURING GRADING OR
EXCAVATING OPERATIONS SHALL BE CLEAN CUT UNDER THE DIRECTION OF
AN ISA CERTIFIED ARBORIST.
6. ANY LIMBS OVERHANGING THE LOD THAT MAY BE RIPPED, TORN, OR
DAMAGED DURING CONSTRUCTION SHALL BE PROPERLY PRUNED UNDER
THE DIRECTION OF AN ISA CERTIFIED ARBORIST.
7. IT IS THE CONTRACTOR'S RESPONSIBILITY TO MAINTAIN THE VEGETATION
AND REMOVE TRASH AND DEBRIS AROUND THE PERIMETER OF THE
PROJECT, EVEN IF WITHIN THE PUBLIC ROW.
PLAN VIEW
NETTING OR EQUIVALENT
2" X 2" POSTS
ORANGE SAFETY
SCALE: N.T.S.
TREE PROTECTION FENCE
CRITICAL ROOT ZONE
TREE DRIPLINE
4' M
IN
10'
TREE PROTECTION FENCING1
C0.41
PROTECT/SUPPORT EXISTING SANITARY
MANHOLE DURING CONSTRUCITON
SA
SA
SA
SA
SA
SA SAS
N/F
FA TUCKER LLC
PIN # 18 213 14 011
N/F
OUR GENERATIONS INC.
PIN # 18 213 14 028
N/F
ISLAND STYLE INVESTMENT LLC
PIN # 18 213 14 010
N/F
ROBERT H. BEASLEY
PIN # 18 213 14 004
N/F
KGEF LLC
PIN # 18 213 14 005
N/F
DAVID S. CARR
PIN # 18 213 14 006
N/F
CARRS PHARMACY INC.
PIN # 18 213 14 007
N/F
LTR INVESTMENTS INC.
PIN # 18 213 12 012
N/F
PARIKH & PARIKH LLC
PIN # 18 213 12 010
N/F
P AND B PROPERTIES LLC
PIN # 18 213 14 008
N/F
MONTREAL PARTNERS LLC
PIN # 18 213 14 008
(BURNETT & ASSOC.)
(TANDEM BANK)
(FURBUSTERS)
PROPERTY LINE
PROPERTY LINE
PROPERTY LINE
PROPERTY LINE
PROPERTY LINE
S
S
SA
SA
S
20' 40'
SCALE: 1 INCH = 20 FEET
10'20' 0'
1ST AVE
3808804
C1.01
TU
C
KE
R
, D
EK
AL
B
C O
U N
TY
, G
EO
R
G
IA
C
IT
Y O
F
TU
C
KE
R
SI
TE
L
AY
O U
T
PL
AN
1S T
AV
E
C O
M
PA
C
TO
R F
AC
IL
IT
Y
FILE NO.
C H
K.
D
R
D
AT
E D
ES
C
R
IP
TI
O
N R
EV
R
EV
IS
IO
N
IN
FO
R
M
AT
IO
N
Copyright 2024, Barge Design Solutions, Inc. ALL RIGHTS RESERVED
T he
C or ne rs
P kw y
Su ite
P ea ch tre e
C or ne rs
, G A
N
E (6
) 5
-9
U
SE
R :J
AC
O
U
SI
N
EA
U
FI
LE
:F
:\3 8\
8\
7\
_C
AD
\C
IV
L\ D ra w in g\
PL
O
T\
Si te
P la n.
dw g
PL
O
TT
ED
:6 /1
6/
SA
VE
D
:4 /1
4/
JA
C
JA
C
-1
5-
D
EK
AL
B C
O U
N
TY
C O
M M
EN
TS
Know what'sbelow Callbefore you dig.
www.call811.com
Know what'sbelow Callbefore you dig.
www.call811.com
JA
C
JA
C
-1
3-
G
EO
R
G
IA
P O
W
ER
N O
TE
S
AN
D
C
AL
LO
U
TS
LEGEND
NOTES:
1. SURVEY PROVIDED BY OWNER. EXISTING TRAIL SIDEWALK
IMPROVEMENTS SHOWN BASED ON PLANS. NO AS-BUILT SURVEY WAS
COMPLETED AFTER SIDEWALK WAS CONSTRUCTED.
2. SUPPLEMENTAL SPOT ELEVATIONS PROVIDED BY THE CITY SHOWN IN
BLUE. TOP OF EXISTING SEWER MANHOLE, ELEVATION 1102.08, AS
IDENTIFIED IN PLAN, WAS USED AS BENCHMARK. SURVEY DATE FEB 14,
2024.
3. COMPACTOR FACILITY FINISHES, COLORS, EXTERIORS, MATERIALS, AND
OVERALL SCHEME TO MATCH ADJACENT TUCKER TOWN GREEN PARK
PROJECT'S SCHEME. SEE STRUCTURAL AND ARCHITECTURAL PLANS.
CONCRETE
EX. SPOT ELEVATION (+1100)
EX. WATERLINE
OVERHEAD POWER LINE
EX. SEWER LINE
EX. GAS LINE
SUPPLEMENTAL EXISTING SPOT
ELEVATION (+1100)
SITE KEYNOTES & DETAIL REFERENCES
GRANITE CURB, 1/C7.02
CURB AND GUTTER, 3/C7.01
CONCRETE PAVEMENT, 2/C7.01, WITH THICKENED
EDGE AND ISOLATION JOINT, ALL EDGES, 9/C7.01
CONCRETE SIDEWALK, 4/C7.01
CONCRETE COMPACTOR PAD AND APPROACH PAD,
3/S1.01, APPROACH PAD WITH THICKENED EDGE, ALL
EDGES, 4/S3.01
PARKING STRIPING, 4" WHITE PAINTED LINES
CROSSWALK STRIPING, 7/C7.01
PIPE BOLLARD (3 IN ENCLOSURE, 1 AT
CORNER),9/S3.01
COMPACTOR GUIDES & STOPS, 2/C7.02
SELF-CONTAINED 30 CY COMPACTOR (PROVIDED AND
INSTALLED BY DEKALB CO. SANITATION)
COMPACTOR REMOTE POWER UNIT (PROVIDED AND
INSTALLED BY DEKALB CO. SANITATION)
METAL GATES (PROVIDED BY CITY), 3/S1.01
DETECTABLE WARNING STRIP, 5/C7.01
REPLACE CONCRETE WALL TO MATCH EXISTING AS
REQ'D AT REAR OF ENCLOSURE
4" THICK CONCRETE ISLAND, 4/C7.01
GRASS ISLAND
RESTORE & BACKFILL SANITARY UTILITY EXCAVATION
PER DETAIL G-004 AND G-005 ON SHEET C7.02
ENCLOSURE WALL, SEE S0.01 TO S3.01 (BRICK COLOR
CHOICE BY CITY)
SIDE ENTRY DOOR WITH 4-BUTTON CODE LOCK,
SWING AS SHOWN, 2/S3.01, 5/S3.01 (PAINT TO MATCH
CITY CHOICE BRICK COLOR
ELECTRICAL PANEL, 1/E5.01
ELECTRICAL METER, 1/55.01
SEWER DRAIN & GRATE, 6/C7.01
GRANITE CURB
CURB & GUTTER
COMPACTOR PAD AND APPROACH PAD
CONCRETE SIDEWALK/ISLAND
5' 10'
SCALE: 1 INCH = 5 FEET
0'
ENCLOSURE WALL
13 16
EXISTING RIGHT OF WAY
EXISTING RIGHT OF WAY
MILL AND OVERLAY PAVEMENT
PIN # 18 213 14 011
N/F
OUR GENERATIONS INC.
PIN # 18 213 14 028
N/F
ISLAND STYLE INVESTMENT LLC
PIN # 18 213 14 010
N/F
ROBERT H. BEASLEY
PIN # 18 213 14 004
N/F
KGEF LLC
PIN # 18 213 14 005
N/F
DAVID S. CARR
PIN # 18 213 14 006
N/F
CARRS PHARMACY INC.
PIN # 18 213 14 007
N/F
LTR INVESTMENTS INC.
PIN # 18 213 12 012
N/F
P AND B PROPERTIES LLC
PIN # 18 213 14 008
N/F
MONTREAL PARTNERS LLC
PIN # 18 213 14 008
(BURNETT & ASSOC.)
(TANDEM BANK)
(FURBUSTERS)
PROPERTY LINE
PROPERTY LINE
PROPERTY LINE
PROPERTY LINE
PROPERTY LINE
S
S
SA
SA
S
TOP ENCLOSURE
WALL ELEV. 11.9
TOC:4.4
BOC:3.9
TOC:5.0
BOC:4.5
TOC:4.5
BOC:4.0
TOC:5.44
BOC:4.94
3.9
3.9
SEWER DRAIN AND GRATE, TOP 3.8
(SEE DETAIL 6/C7.01)
3.9
3.7
3.6
3.4
TOC:4.7
BOC:4.2
1.96
TOC:4.45
BOC:4.11
TOC:4.55
BOC:4.05
TOC:4.33
BOC:3.83
TOC:4.7
2.5
2.3
3.9
3.9
4.4
4.5
4.6
3.8
4.3
4.2
4.0
3.9
TOP ENCLOSURE WALL ELEV. 11.9
(SEE SHEETS S0.01 TO S3.01)
3.3
3.2
3.1
3.0
2.9
2.8
2.7
2.71
2.1
2.98
3.15
3.37
4.0
3.5
3.6
3.85
4.14.2
4.3
4.1
4.4 4.5
1%
1%
1%
1%
1%
20' 40'
SCALE: 1 INCH = 20 FEET
10'20' 0'
1ST AVE
M
AIN
ST
3808804
C2.01
TU
C
KE
R
, D
EK
AL
B
C O
U N
TY
, G
EO
R
G
IA
C
IT
Y O
F
TU
C
KE
R
G R
AD
IN
G A
N D
D R
AI
N
AG
E
PL
AN
1S T
AV
E
C O
M
PA
C
TO
R F
AC
IL
IT
Y
FILE NO.
C H
K.
D
R
D
AT
E D
ES
C
R
IP
TI
O
N R
EV
R
EV
IS
IO
N
IN
FO
R
M
AT
IO
N
Copyright 2024, Barge Design Solutions, Inc. ALL RIGHTS RESERVED
T he
C or ne rs
P kw y
Su ite
P ea ch tre e
C or ne rs
, G A
N
E (6
) 5
-9
U
SE
R :J
AC
O
U
SI
N
EA
U
FI
LE
:F
:\3 8\
8\
7\
_C
AD
\C
IV
L\ D ra w in g\
PL
O
T\
G ra di ng
P la n.
dw g
PL
O
TT
ED
:6 /1
6/
SA
VE
D
:4 /1
4/
JA
C
JA
C
-1
5-
D
EK
AL
B C
O U
N
TY
C O
M M
EN
TS
Know what'sbelow Callbefore you dig.
www.call811.com
Know what'sbelow Callbefore you dig.
www.call811.com
JA
C
JA
C
-1
3-
G
EO
R
G
IA
P O
W
ER
N O
TE
S
AN
D
C
AL
LO
U
TS
LEGEND
EXISTING CONTOUR
SPOT ELEVATION (+1100)
EX. WATERLINE
OVERHEAD POWER LINE
EX. SEWER LINE
EX. GAS LINE
SUPPLEMENTAL EXISTING SPOT ELEVATION
(+1100)
PROPOSED CONTOUR
PROPOSED SPOT ELEVATION (+1100)
TOP OF CURB ELEVATION (+1100)
BOTTOM OF CURB ELEVATION (+1100)
WATER FLOW PATH
GRADING & DRAINAGE NOTES:
1. SURVEY PROVIDED BY OWNER. EXISTING TRAIL SIDEWALK
IMPROVEMENTS SHOWN BASED ON PLANS. NO AS-BUILT SURVEY WAS
COMPLETED AFTER SIDEWALK WAS CONSTRUCTED.
2. SUPPLEMENTAL SPOT ELEVATIONS PROVIDED BY THE CITY SHOWN IN
BLUE. TOP OF EXISTING SEWER MANHOLE, ELEVATION 1102.08, AS
IDENTIFIED IN PLAN, WAS USED AS BENCHMARK. SURVEY DATE FEB 14,
2024.
3. CONTRACTOR TO VERIFY LOCATIONS OF EXISTING UTILITIES PRIOR TO
CONSTRUCTION.
4. EXISTING DRAIN DOWNSPOUTS SPLASH ON PROPOSED GRADE.
MATCH EXISTING GRADE
BOC:4.0
3.2
TOC:4.5
MATCH EXISTING GRADE
MATCH EXISTING GRADE
MATCH EXISTING GRADE
SLOPED ISLAND
MATCH EXISTING GRADE
GRADE SWALE PER
SPOT ELEVATIONS
MATCH EXISTING GRADE
AT EXISTING SIDEWALK
MATCH EXISTING GRADE
MATCH EXISTING GRADE
MATCH EXISTING GRADE
MATCH EXISTING GRADE
SWALE WITH FRENCH DRAIN
CENTERLINE (SEE DETAIL
SHEET C7.01)
CORE 8" FRENCH DRAIN PIPE INTO
EXISTING STORM STRUCTURE -
MATCH STRUCTURE OUTLET INVERT
ELEVATION
PIN # 18 213 14 011
N/F
OUR GENERATIONS INC.
PIN # 18 213 14 028
N/F
ISLAND STYLE INVESTMENT LLC
PIN # 18 213 14 010
N/F
ROBERT H. BEASLEY
PIN # 18 213 14 004
N/F
KGEF LLC
PIN # 18 213 14 005
N/F
DAVID S. CARR
PIN # 18 213 14 006
N/F
CARRS PHARMACY INC.
PIN # 18 213 14 007
N/F
LTR INVESTMENTS INC.
PIN # 18 213 12 012
N/F
P AND B PROPERTIES LLC
PIN # 18 213 14 008
N/F
MONTREAL PARTNERS LLC
PIN # 18 213 14 008
(BURNETT & ASSOC.)
(TANDEM BANK)
(FURBUSTERS)
PROPERTY LINE
PROPERTY LINE
PROPERTY LINE
PROPERTY LINE
PROPERTY LINE
UGP
UG
P
UG
P
UGP
U G
P
S
S
SA
SA
S
UTILITIES KEYNOTES & DETAIL REFERENCES
REPLACE ASPHALT PAVEMENT (1/C7.01) AND GRANITE
CURB (1/C7.02)
DUCT/CONDUIT ROUTING, 4/E5.01 - CONDUIT TO BE
PROVIDED BY GEORGIA POWER
SEWER DRAIN AND GRATE, 6/C7.01
CLEANOUT, 8/C7.01
DUCT/CONDUIT ROUTING UNDER FOOTING, SEE
DETAIL 6/S3.01
SEWER LATERAL UNDER FOOTING, SEE DETAIL
6/S3.01
CORE INTO EXISTING MANHOLE
20' 40'
SCALE: 1 INCH = 20 FEET
10'20' 0'
1ST AVE
3808804
C3.01
TU
C
KE
R
, D
EK
AL
B
C O
U N
TY
, G
EO
R
G
IA
C
IT
Y O
F
TU
C
KE
R
SI
TE
U
TI
LI
TI
ES
P
LA
N
1S T
AV
E
C O
M
PA
C
TO
R F
AC
IL
IT
Y
FILE NO.
C H
K.
D
R
D
AT
E D
ES
C
R
IP
TI
O
N R
EV
R
EV
IS
IO
N
IN
FO
R
M
AT
IO
N
Copyright 2024, Barge Design Solutions, Inc. ALL RIGHTS RESERVED
T he
C or ne rs
P kw y
Su ite
P ea ch tre e
C or ne rs
, G A
N
E (6
) 5
-9
U
SE
R :J
AC
O
U
SI
N
EA
U
FI
LE
:F
:\3 8\
8\
7\
_C
AD
\C
IV
L\ D ra w in g\
PL
O
T\
U tl
Pl an
.d w g
PL
O
TT
ED
:6 /1
6/
SA
VE
D
:6 /1
3/
JA
C
JA
C
-1
5-
D
EK
AL
B C
O U
N
TY
C O
M M
EN
TS
Know what'sbelow Callbefore you dig.
www.call811.com
Know what'sbelow Callbefore you dig.
www.call811.com
JA
C
JA
C
-1
3-
G
EO
R
G
IA
P O
W
ER
N O
TE
S
AN
D
C
AL
LO
U
TS
UTILITY NOTES
1. ALL WORK ASSOCIATED WITH THE WATER AND SEWER IMPROVEMENTS SHALL COMPLY
WITH DEKALB COUNTY DEPARTMENT OF WATERSHED MANAGEMENT DEVELOPMENT
REGULATIONS.
2. CONTRACTOR TO COORDINATE INSPECTIONS.
SA
SEE SEWER PROFILE , C4.01 DEKALB
COUNTY OWNED/MAINTAINED
LEGEND
EXISTING CONTOUR
EX. SPOT ELEVATION (+1100)
EX. WATERLINE
OVERHEAD POWER LINE
UNDERGROUND POWER LINE
EX. SEWER LINE
EX. GAS LINE
SUPPLEMENTAL EX. SPOT ELEVATION (+1100)
PROPOSED SEWER LATERAL (6" DIP)
PROPOSED UNDERGROUND DUCT/CONDUIT
ROUTING
NOTES:
1. SURVEY PROVIDED BY OWNER. EXISTING TRAIL SIDEWALK
IMPROVEMENTS SHOWN BASED ON PLANS. NO AS-BUILT SURVEY WAS
COMPLETED AFTER SIDEWALK WAS CONSTRUCTED.
2. SUPPLEMENTAL SPOT ELEVATIONS PROVIDED BY THE CITY SHOWN IN
BLUE. TOP OF EXISTING SEWER MANHOLE, ELEVATION 1102.08, AS
IDENTIFIED IN PLAN, WAS USED AS BENCHMARK. SURVEY DATE FEB 14,
2024.
3. CONTRACTOR SHALL INSTALL FITTINGS AS REQUIRED TO PROVIDE
FOR SEWER DRAIN, TRAP, VENT AND HORIZONTAL ALIGNMENT
DEFLECTIONS.
4. COMPACTOR FACILITY FINISHES, COLORS, EXTERIORS, MATERIALS,
AND OVERALL SCHEME TO MATCH ADJACENT TUCKER TOWN GREEN
PARK PROJECT'S SCHEME. SEE STRUCTURAL AND ARCHITECTURAL
PLANS.
5. SEE GEORGIA POWER NOTES AND CALLOUTS THIS SHEET FOR POWER
REQUIREMENTS.
CONTRACTOR TO FIELD
VERIFY DUCT/CONDUIT
ROUTING WITH EX. UTILITIES
CONTRACTOR SHALL PROVIDE PRICING FOR
ALTERNATE HORIZONTAL DIRECTION DRILLING
METHOD FOR INSTALLATION OF TWO 3-INCH
CONDUITS. AT A MINIMUM THIS SHALL BE
CONSIDERED FOR THE SECTION CROSSING
1ST AVENUE
4' DIAMETER MANHOLE DEKALB
COUNTY OWNED/MAINTAINED
6" DIP SEWER LATERAL CITY OF
TUCKER OWNED/MAINTAINED
8" DIP SEWER MAIN DEKALB
COUNTY OWNED/MAINTAINED
M
AIN
STR
EET
SEE SEWER PROFILE , C4.01 CITY
OF TUCKER OWNED/MAINTAINED
1,000 GALLON GREASE TRAP SEE
DEKALB STANDARD DETAIL SHEET C7.03
CITY OF TUCKER OWNED/MAINTAINED
6" DIP SEWER LATERAL CITY OF
TUCKER OWNED/MAINTAINEDEXISTING WATER MAIN
CITY OF TUCKER
RIGHT OF WAY
CITY OF TUCKER
RIGHT OF WAY
17.87'
19.11'
14.10'
WL1
INSTALL:
- 35' 1/0QA TO WL2
CONTACTOR TO COORDINATE WITH
GEORGIA POWER
WL2
INSTALL:
- 40' CLASS 5 POLE
- 3PH PRI TANGENT ARM
- 150' 1/0UQA TO WL3
- 3" RISER SHIELD
- PULL 110' OF SVC WIRE THRU
CUST INSTALLED CONDUIT
WL3
INSTALL:
- 200 A METER
COMPACTOR SANITARY -0+25 TO 3+25
SCALE: 1"=20' H
1"=4' V
4' MANHOLE
EX. GRADE
PROPOSED GRADE
N E
W
IN
V
IN
:1
3.
EXISTING GAS SERVICE
APPROXIMATE LOCATION
AND ELEVATION
EXISTING WATER SERVICE
APPROXIMATE LOCATION
AND ELEVATION
EXISTING GAS SERVICE
APPROXIMATE LOCATION
AND ELEVATION
EXISTING WATER SERVICE
APPROXIMATE LOCATION
AND ELEVATION
EX
IS
TI
N G
M
AN
H O
LE
ST
A:
0+
.0
TO
P:
.1
IN
V
IN
:1
3.
E
215 LF 8" DIP @ 2.00%
28 LF 6" DIP @ 2.00%
24 LF 6" DIP @ 2.00%
PR
O
PO
SE
D M
AN
H
O
LE
ST
A:
+1
4.
TO
P:
.4
IN
V
IN
:1
8.
S E
IN
V
O U
T:
.2
W
PR
O
PO
SE
D M
AN
H
O
LE
ST
A:
+1
4.
TO
P:
.4
IN
V
IN
:1
8.
S E
IN
V
O U
T:
.2
W
P R
O P
O S
E D
" C
LE
A
N O
U T
C O
M P
A C
TO
R
D R
A
IN
S E
E D
E
TA
IL
S
H E
E T
C 7.
PROPOSED 1,000 GALLON
GREASE TRAP
SEE DETAIL SHEET C7.03
P R
O P
O S
E D
G R
E A
S E
T R
A P
S
TA
:2 +4
6.
TO
P
: 1
4.
IN
V
IN
: 1
9.
IN
V O
U T:
9.
3'
3.09'
2.81' 13 LF 6" DIP @ 2.01%
3.54' 2.11'
3808804
C4.01
TU
C
KE
R
, D
EK
AL
B
C O
U N
TY
, G
EO
R
G
IA
C
IT
Y O
F
TU
C
KE
R
SE
W
ER
L
AT
ER
AL
P
R O
FI
LE
1S T
AV
E
C O
M
PA
C
TO
R F
AC
IL
IT
Y
FILE NO.
C H
K.
D
R
D
AT
E D
ES
C
R
IP
TI
O
N R
EV
R
EV
IS
IO
N
IN
FO
R
M
AT
IO
N
Copyright 2024, Barge Design Solutions, Inc. ALL RIGHTS RESERVED
T he
C or ne rs
P kw y
Su ite
P ea ch tre e
C or ne rs
, G A
N
E (6
) 5
-9
U
SE
R :J
AC
O
U
SI
N
EA
U
FI
LE
:F
:\3 8\
8\
7\
_C
AD
\C
IV
L\ D ra w in g\
PL
O
T\
Pr of ile .d w g
PL
O
TT
ED
:6 /1
6/
SA
VE
D
:5 /1
9/
JA
C
JA
C
-1
5-
D
EK
AL
B C
O U
N
TY
C O
M M
EN
TS
Know what'sbelow Callbefore you dig.
www.call811.com
Know what'sbelow Callbefore you dig.
www.call811.com
JA
C
JA
C
-1
3-
G
EO
R
G
IA
P O
W
ER
N O
TE
S
AN
D
C
AL
LO
U
TS
NOTES:
1. SURVEY PROVIDED BY OWNER. EXISTING TRAIL SIDEWALK
IMPROVEMENTS SHOWN BASED ON PLANS. NO AS-BUILT SURVEY WAS
COMPLETED AFTER SIDEWALK WAS CONSTRUCTED.
2. CONTRACTOR TO INSTALL FITTINGS AS REQUIRED TO PROVIDE FOR
INLINE TRAP AND HORIZONTAL ALIGNMENT DEFLECTIONS.
3. THE CONTRACTOR SHALL VERIFY THE LOCATIONS AND INVERTS OF ALL
EXISTING UTILITY LINES AND STRUCTURES (INCLUDING STORM
DRAINAGE PIPES OR STRUCTURES) BEFORE THE COMMENCEMENT OF
CONSTRUCTION.
10' 20' 40'
HORIZONTAL SCALE: 1 INCH = 20 FEET
20' 0'
VERTICAL SCALE: 1 INCH = 4 FEET
PIN # 18 213 14 011
N/F
OUR GENERATIONS INC.
PIN # 18 213 14 028
N/F
ISLAND STYLE INVESTMENT LLC
PIN # 18 213 14 010
N/F
ROBERT H. BEASLEY
PIN # 18 213 14 004
N/F
KGEF LLC
PIN # 18 213 14 005
N/F
DAVID S. CARR
PIN # 18 213 14 006
N/F
CARRS PHARMACY INC.
PIN # 18 213 14 007
N/F
LTR INVESTMENTS INC.
PIN # 18 213 12 012
N/F
PARIKH & PARIKH LLC
PIN # 18 213 12 010
N/F
P AND B PROPERTIES LLC
PIN # 18 213 14 008
N/F
MONTREAL PARTNERS LLC
PIN # 18 213 14 008
(BURNETT & ASSOC.)
(TANDEM BANK)
(FURBUSTERS)
PROPERTY LINE
PROPERTY LINE
PROPERTY LINE
PROPERTY LINE
PROPERTY LINE
S
S
SA
SA
S
20' 40'
SCALE: 1 INCH = 20 FEET
10'20' 0'
EROSION CONTROL NOTES:
1. SEE SHEETS C7.02 FOR DETAILS OF EROSION CONTROL BMPS.
2. CLEARING AND GRUBBING SHALL BE LIMITED TO THAT NECESSARY FOR
THE INSTALLATION OF INITIAL PHASE BMP'S.
3. EXISTING BMP'S SHALL BE MAINTAINED AND REPAIRED AS NECESSARY.
EXISTING BMP'S MAY BE REMOVED AS NECESSARY FOR PROJECT
DEVELOPMENT.
4. WASTE MATERIALS SHALL NOT BE DISCHARGED TO WATERS OF THE STATE,
EXCEPT AS AUTHORIZED BY A SECTION 404 PERMIT.
5. THE ESCAPE OF SEDIMENT FROM THE SITE SHALL BE PREVENTED BY THE
INSTALLATION OF EROSION AND SEDIMENT CONTROL MEASURES AND
PRACTICES PRIOR TO LAND DISTURBING ACTIVITIES.
6. EROSION CONTROL MEASURES SHALL BE MAINTAINED AT ALL TIMES. IF FULL
IMPLEMENTATION OF THE APPROVED PLAN DOES NOT PROVIDE FOR
EFFECTIVE EROSION CONTROL, ADDITIONAL EROSION AND SEDIMENT
CONTROL MEASURES SHALL BE IMPLEMENTED TO CONTROL OR TREAT THE
SEDIMENT SOURCE.
7. EROSION CONTROL MEASURES WILL BE INSPECTED AT LEAST WEEKLY AND
AFTER EACH RAIN, AND REPAIRED BY THE GENERAL CONTRACTOR AS
NEEDED.
8. ALL DESIGN WILL CONFORM TO AND ALL WORK WILL BE PERFORMED IN
ACCORDANCE WITH THE STANDARDS AND SPECIFICATIONS OF THE
CURRENT PUBLICATION ENTITLED "MANUAL FOR EROSION AND SEDIMENT
CONTROL IN GEORGIA".
9. MAINTENANCE OF ALL SOIL EROSION AND SEDIMENTATION CONTROL
MEASURES AND PRACTICES, WHETHER TEMPORARY OR PERMANENT, SHALL
BE AT ALL TIMES THE RESPONSIBILITY OF THE CONTRACTOR.
10. TREE PROTECTION MEASURES SHALL BE INSTALLED PRIOR TO LAND
DISTURBING ACTIVITIES.
11. ALL DISTURBED AREAS OUTSIDE CONCRETE SHALL BE STABILIZED WITH
PERMANENT VEGETATION.
12. ALL EROSION CONTROL DEVICES TO BE REMOVED UPON FINAL
STABILIZATION OF DISTURBED AREAS.
1ST AVE
M
AIN
ST
3808804
EC1.01
TU
C
KE
R
, D
EK
AL
B
C O
U N
TY
, G
EO
R
G
IA
C
IT
Y O
F
TU
C
KE
R
ER
O
SI
O
N C
O N
TR
O
L
PL
AN
1S T
AV
E
C O
M
PA
C
TO
R F
AC
IL
IT
Y
FILE NO.
C H
K.
D
R
D
AT
E D
ES
C
R
IP
TI
O
N R
EV
R
EV
IS
IO
N
IN
FO
R
M
AT
IO
N
Copyright 2024, Barge Design Solutions, Inc. ALL RIGHTS RESERVED
T he
C or ne rs
P kw y
Su ite
P ea ch tre e
C or ne rs
, G A
N
E (6
) 5
-9
U
SE
R :J
AC
O
U
SI
N
EA
U
FI
LE
:F
:\3 8\
8\
7\
_C
AD
\C
IV
L\ D ra w in g\
PL
O
T\
ES
PC
P la n.
dw g
PL
O
TT
ED
:6 /1
6/
SA
VE
D
:4 /1
1/
JA
C
JA
C
-1
5-
D
EK
AL
B C
O U
N
TY
C O
M M
EN
TS
Know what'sbelow Callbefore you dig.
www.call811.com
Know what'sbelow Callbefore you dig.
www.call811.com
JA
C
JA
C
-1
3-
G
EO
R
G
IA
P O
W
ER
N O
TE
S
AN
D
C
AL
LO
U
TS
LEGEND
EXISTING CONTOUR
SPOT ELEVATION
EX. WATERLINE
OVERHEAD POWER LINE
EX. SEWER LINE
EX. GAS LINE
SUPPLEMENTAL EX. SPOT ELEVATION
PROPOSED SILT FENCE
DRAIN INLET FILTER
NOTES:
1. SURVEY PROVIDED BY OWNER. EXISTING TRAIL SIDEWALK
IMPROVEMENTS SHOWN BASED ON PLANS. NO AS-BUILT SURVEY WAS
COMPLETED AFTER SIDEWALK WAS CONSTRUCTED.
2. SUPPLEMENTAL SPOT ELEVATIONS PROVIDED BY THE CITY SHOWN IN
BLUE. TOP OF EXISTING SEWER MANHOLE, ELEVATION 11020.8, AS
IDENTIFIED IN PLAN, WAS USED AS BENCHMARK. SURVEY DATE FEB 14,
2024.
EROSION CONTROL KEYNOTES
SILT FENCE, 4/C7.02
DRAIN INLET FILTER, 3/C7.02
PROJECT AREA: 0.18 AC
DISTURBED AREA: 0.17 AC
DISTURBED AREA
DISTURBED AREADISTURBED AREA
6" CURB
COARSE BROOM
FINISH
6'-0"
NTSC1.01
CL
CL CL
0.2"
0.9" 2.35"
2.35"
NTS
DETECTABLE WARNING STRIP DETAIL
CURB RAMP
NOTES:
1.
2.
3.
4.
5.
6.
7.
NTS
DOME SPACING
DETECTABLE WARNINGS SHALL BE 24 INCHES IN THE DIRECTION OF TRAVEL AND
EXTEND THE FULL WIDTH OF THE CURB RAMP OR FLUSH SURFACE.
THE DETECTABLE WARNING SHALL BE LOCATED DIRECTLY BEHIND THE 6" FLUSH
CURB.
TRUNCATED DOMES SHALL HAVE A DIAMETER OF 0.9 INCH AT THE BOTTOM, 0.4
INCH AT THE TOP, A HEIGHT OF 0.2 INCH, AND A CENTER-TO-CENTER SPACING OF
2.35 INCHES MEASURED ALONG ONE SIDE OF A SQUARE ARRANGEMENT.
DOMES SHALL BE ALIGNED ON A SQUARE GRID IN THE PREDOMINANT DIRECTION
OF TRAVEL TO PERMIT WHEELS TO ROLL BETWEEN DOMES.
THERE SHALL BE A MINIMUM OF 70% CONTRAST IN LIGHT REFLECTANCE
BETWEEN THE DETECTABLE WARNING AND AN ADJOINING SURFACE, OR THE
DETECTABLE WARNING SHALL BE "SAFETY YELLOW". THE MATERIAL USED TO
PROVIDE VISUAL CONTRAST SHALL BE AN INTEGRAL PART OF THE DETECTABLE
WARNING SURFACE.
DETECTABLE WARNING SHALL BE 12" x 12" CONCRETE PAVERS CONFORMING TO
THE CRITERIA LISTED ABOVE.
THE CONTRACTOR SHALL SUBMIT PRODUCT INFORMATION AND COLOR SAMPLES
TO A/E FOR APPROVAL PRIOR TO ORDERING.
VARIES
6" COMPACTED MINERAL
AGGREGATE BASE, TYPE "A"
GRADING "D"
COMPACTED SUBGRADE
8.0" CONCRETE
SURFACE,
4000 P.S.I.
C1.01
2 CONCRETE PAVEMENT
SCALE: NTS
6"
VARIES - SEE PLAN
(5' MIN.)
NOTES:
1. PREFORMED 1/2" EXPANSION JOINTS SHALL BE EQUALLY SPACED AT 25'
CENTERS.
2. 1/4" CONTRACTION JOINTS SHALL BE EQUALLY SPACED AT 5' CENTERS
BETWEEN EXPANSION JOINTS.
3. SEE PLANS FOR SPECIFIC AND/OR SPECIAL JOINT LAYOUTS, IF ANY.
4. 1.5% CROSS SLOPE TYPICAL FOR POSITIVE DRAINAGE.
5. 2.0% ABSOLUTE MAXIMUM CROSS SLOPE, STRICTLY ENFORCED.
6. SIDEWALK TO HAVE MEDIUM BROOM FINISH PERPENDICULAR TO PRIMARY
DIRECTION OF TRAVEL.
7. 1
2" EXPANSION JOINT TO BE PLACED BETWEEN EXISTING BUILDINGS AND
COMPACTOR FACILITY
SLOPE (SEE PLAN)
4" MINERAL
AGGREGATE BASE.COMPACTED EARTH
FINISH GRADE
4" CONCRETE
(4000 PSI)
6"
C1.01
4 CONCRETE SIDEWALK
SCALE: NTS
3808804
C7.01
TU
C
KE
R
, D
EK
AL
B
C O
U N
TY
, G
EO
R
G
IA
C
IT
Y O
F
TU
C
KE
R
SI
TE
D
ET
AI
LS
1S T
AV
E
C O
M
PA
C
TO
R F
AC
IL
IT
Y
C3.01
6 SEWER DRAIN AND GRATE
SCALE: NTS
FILE NO.
C H
K.
D
R
D
AT
E D
ES
C
R
IP
TI
O
N R
EV
R
EV
IS
IO
N
IN
FO
R
M
AT
IO
N
Copyright 2024, Barge Design Solutions, Inc. ALL RIGHTS RESERVED
T he
C or ne rs
P kw y
Su ite
P ea ch tre e
C or ne rs
, G A
N
E (6
) 5
-9
U
SE
R :J
AC
O
U
SI
N
EA
U
FI
LE
:F
:\3 8\
8\
7\
_C
AD
\C
IV
L\ D ra w in g\
PL
O
T\
Si te
D et ai ls
.d w g
PL
O
TT
ED
:6 /1
6/
SA
VE
D
:4 /1
1/
JA
C
JA
C
-1
5-
D
EK
AL
B C
O U
N
TY
C O
M M
EN
TS
JA
C
JA
C
-1 3-
G
EO
R G
IA
P
O W
ER
N
O
TE
S
AN
D C
AL
LO
U
TS
C3.01
8 CLEANOUT
SCALE: NTS
TOP OF CLEANOUT CAP
TO MATCH PAVED
FINISHED GRADE
2'X2'X6" THICK
CONCRETE COLLAR W/
FINISHED GRADE
BACKFILL WITH SELECT
EXCAVATED MATERIAL
FOR PAVED AREAS
45° BENDS
SEWER LATERAL
NOTE: SEE PLAN SHEET(S) FOR ELEVATION
CONTRACTOR TO PROVIDE
REQ'D FITTINGS TO TRANSITION
TO 6" PVC SEWER LATERAL
NOTE: EMBED IN CONCRETE, SEE DETAIL 6/S3.01
UPSLOPE
SOD LAID OVER
COARSE SAND LAYER
4" COARSE SAND
LAYER
2" LAYER PEA GRAVEL
NOTES:
1. TRENCH MUST BE NO LESS THAN 14" WIDE AND 14" DEEP.
2. MINIMUM SLOPE TO VARY AS REQUIRED TO PROVIDE POSITIVE DRAINAGE.
C2.01
1 FRENCH DRAIN DETAIL
SCALE: NTS
8" DIA. ADS N-12
CORRUGATED,
PERFORATED HDPE PIPE
OR APPROVED EQUAL
2%2%
SEE PLAN FOR GRADING
6 OZ/SQ. YD. MIN. NON-WOVEN
GEOTEXTILE FABRIC AROUND
TRENCH WALLS WITH OVERLAP
12" MIN. OVERLAP
FOR FABRIC
3808804
C7.02
TU
C
KE
R
, D
EK
AL
B
C O
U N
TY
, G
EO
R
G
IA
C
IT
Y O
F
TU
C
KE
R
SI
TE
D
ET
AI
LS
1S T
AV
E
C O
M
PA
C
TO
R F
AC
IL
IT
Y
NOTE: MOUNT TO SLAB WITH 12" DIA. ADHESIVE ANCHR AT 24" O.C., EMBED 3 5 8" INTO SLAB.
FILE NO.
C H
K.
D
R
D
AT
E D
ES
C
R
IP
TI
O
N R
EV
R
EV
IS
IO
N
IN
FO
R
M
AT
IO
N
Copyright 2024, Barge Design Solutions, Inc. ALL RIGHTS RESERVED
T he
C or ne rs
P kw y
Su ite
P ea ch tre e
C or ne rs
, G A
N
E (6
) 5
-9
U
SE
R :J
AC
O
U
SI
N
EA
U
FI
LE
:F
:\3 8\
8\
7\
_C
AD
\C
IV
L\ D ra w in g\
PL
O
T\
Si te
D et ai ls
.d w g
PL
O
TT
ED
:6 /1
6/
SA
VE
D
:4 /1
1/
JA
C
JA
C
-1
5-
D
EK
AL
B C
O U
N
TY
C O
M M
EN
TS
JA
C
JA
C
-1 3-
G
EO
R G
IA
P
O W
ER
N
O
TE
S
AN
D C
AL
LO
U
TS
SIDE VIEW
FLOW
18" MIN.
30" MIN. *
6"
2"
4' MAX. O.C.
FABRIC
(WOVEN WIRE
FENCE BACKING)
TRENCH
6"
18" MIN.
FRONT VIEW
NOTES:
1. USE STEEL OR WOOD POSTS OR AS SPECIFIED BY THE EROSION, SEDIMENTATION, AND
POLLUTION CONTROL PLAN.
2. HEIGHT (3') IS TO BE SHOWN ON THE EROSION, SEDIMENTATION, AND POLLUTION CONTROL PLAN.
3. C-POP IS APPROVED ALTERNATIVE.
30" MIN.
18" MIN.
6"
TRENCH
FABRIC
(WOVEN WIRE
FENCE BACKING)
4' MAX. O.C.
* FLOW
C4.01
1 GRANITE CURB
SCALE: NTS
10'
10'
C4.01
2 GUIDES AND STOPS
SCALE: NTS
DRAIN INLET SECTION
FILTREXX® 8" SOXX™ OR
APPROVED EQUIVALENT
STORM GRATE
WIRE TIES, (TYP.)
DRAIN INLET PLAN
NOTES:
1. ALL MATERIAL TO MEET FILTREXX® OR APPROVE EQUIVALENT SPECIFICATIONS.
2. FILTERING FILL MEDIA TO MEET APPLICATION REQUIREMENTS.
3. COMPOST MATERIAL TO BE DISPERSED ON SITE, AS DETERMINED BY ENGINEER.
FILTREXX® 8" SOXX™ OR
APPROVED EQUIVALENT
CATCH
BASIN
N.T.S.
3 DRAIN INLET FILTER
EC1.01
N.T.S.
4 SILT FENCE - TYPE SENSITIVE
EC1.01
C1.01
9 THICKENED EDGE AND ISOLATION JOINT
SCALE: NTS
STRUCTURE
OR ASPHALT
TOOLED WITH 18" RADIUS 12"
PREMOLDED JOINT FILLER
C1.01
3 TYPICAL CURB & GUTTER DETAIL
SCALE: NTS
12"
1"R
6"18"
6"
1"
2"R
SLOPE: 1" PER 18"
4"
COMPACTED GAB
3808804
C7.03
TU
C
KE
R
, D
EK
AL
B
C O
U N
TY
, G
EO
R
G
IA
C
IT
Y O
F
TU
C
KE
R
SI
TE
D
ET
AI
LS
1S T
AV
E
C O
M
PA
C
TE
R D
ES
IG
N
FILE NO.
C H
K.
D
R
D
AT
E D
ES
C
R
IP
TI
O
N R
EV
R
EV
IS
IO
N
IN
FO
R
M
AT
IO
N
Copyright 2024, Barge Design Solutions, Inc. ALL RIGHTS RESERVED
T he
C or ne rs
P kw y
Su ite
P ea ch tre e
C or ne rs
, G A
N
E (6
) 5
-9
U
SE
R :J
AC
O
U
SI
N
EA
U
FI
LE
:F
:\3 8\
8\
7\
_C
AD
\C
IV
L\ D ra w in g\
PL
O
T\
Si te
D et ai ls
.d w g
PL
O
TT
ED
:6 /1
6/
SA
VE
D
:4 /1
1/
JA
C
JA
C
-1
5-
D
EK
AL
B C
O U
N
TY
C O
M M
EN
TS
JA
C
JA
C
-1 3-
G
EO
R G
IA
P
O W
ER
N
O
TE
S
AN
D C
AL
LO
U
TS
CODES AND STANDARDS
THE FOLLOWING CODES AND STANDARDS HAVE BEEN USED AS THE BASIS FOR DESIGN
AND/OR SHALL BE UTILIZED BY THE CONTRACTOR TO ESTABLISH MINIMUM LEVELS OF
QUALITY AND CONSTRUCTION TECHNIQUES.
1. GENERAL
A. INTERNATIONAL BUILDING CODE (IBC 2018). WITH GEORGIA AMMENDMENTS
B. AMERICAN SOCIETY OF CIVIL ENGINEERS, "MINIMUM DESIGN LOADS AND
ASSOCIATED CRITERIA FOR BUILDINGS AND OTHER STRUCTURES," (ASCE 7-16).
2. CONCRETE
A. AMERICAN CONCRETE INSTITUTE, "BUILDING CODE REQUIREMENTS FOR
STRUCTURAL CONCRETE" (ACI 318-14).
B. AMERICAN CONCRETE INSTITUTE, "SPECIFICATIONS FOR STRUCTURAL
CONCRETE," (ACI 301-16).
C. AMERICAN CONCRETE INSTITUTE, "GUIDE TO CONCRETE FLOOR AND SLAB
CONSTRUCTION" (ACI 302.1R-15).
3. MASONRY
A. THE MASONRY SOCIETY, "BUILDING CODE REQUIREMENTS FOR MASONRY
STRUCTURES," (TMS 402-16).
B. THE MASONRY SOCIETY, "SPECIFICATION FOR MASONRY STRUCTURES," (TMS
602-16).
THE STRUCTURE HAS BEEN DESIGNED FOR THE FOLLOWING LOADS.
1. DEAD LOADS: ACTUAL WEIGHTS OF BUILDING MATERIALS, STRUCTURAL COMPONENTS,
AND EQUIPMENT.
2. LIVE LOADS
A. FLOOR LIVE LOADS
1. SLAB-ON-GRADE UNIFORM LOAD 125 PSF
3. WIND LOADS
A. ENCLOSURE
1. ULTIMATE DESIGN WIND SPEED (Vult) 107 MPH
2. ALLOWABLE STRESS DESIGN WIND SPEED (Vasd) 82.9 MPH
3. RISK CATEGORY II
4. EXPOSURE CATEGORY C
5. INTERNAL PRESSURE COEFF. (GCpi) N/A
6. C & C WIND PRESSURES SEE SCHEDULE (THIS SHEET)
4. SEISMIC LOADS
A. ENCLOSURE
1. RISK CATEGORY II
2. SEISMIC IMPORTANCE FACTOR (Ie) 1.0
3. 0.2 SEC MAPPED SPECTRAL ACCELERATION (SS) 0.187
4. 1.0 SEC MAPPED SPECTRAL ACCELERATION (S1) 0.086
5. SITE CLASS D - Default
6. 0.2 SEC DESIGN SPECTRAL ACCELERATION (SDS) 0.20
7. 1.0 SEC DESIGN SPECTRAL ACCELERATION (SD1) 0.137
8. SEISMIC DESIGN CATEGORY C
9. BASIC SEISMIC FORCE RESISTING SYSTEM N/A
DESIGN CRITERIA
5 5 a a h a a θ
1. MINIMUM 28 DAY CONCRETE COMPRESSIVE STRENGTH SHALL BE AS FOLLOWS:
A. CONTINUOUS FOOTINGS 3,000 PSI
B. FLOOR SLABS 4,000 PSI
2. CONCRETE SHALL BE PROPORTIONED, BATCHED, MIXED, PLACED,
CONSOLIDATED, AND CURED IN ACCORDANCE WITH ACI 301, 304, 308, 309 AND 318.
3. ALL CONCRETE EXPOSED TO WEATHER SHALL BE AIR ENTRAINED.
4. WHERE STRIP/GRADE FOOTINGS OR WALLS INTERSECT COLUMN FOUNDATIONS,
LONGITUDINAL REINFORCEMENT SHALL BE CONTINUOUS THROUGH THE COLUMN
FOUNDATION.
5. UNLESS OTHERWISE SHOWN, THE CONCRETE CLEAR COVER AT ALL
REINFORCING STEEL SHALL BE:
A. CONCRETE CAST AGAINST EARTH 3"
B. CONCRETE EXPOSED TO EARTH OR WEATHER 2"
C. CONCRETE NOT EXPOSED TO EARTH OR WEATHER 3/4"
6. ALL CONCRETE SHALL BE MECHANICALLY VIBRATED IN ACCORDANCE WITH ACI
304 AND ACI 309.
7. PROVIDE 3/4"x3/4"x 45 DEGREE CHAMFERED CORNERS AT ALL EXPOSED
CONCRETE CORNERS UNO.
8. ALL EXTERIOR CONCRETE SHALL BE AIR ENTRAINED PER ACI 318.
CONCRETE
1. REINFORCING STEEL SHALL CONFORM TO ASTM A615, GRADE 60
(DEFORMED).
2. DETAILING, FABRICATION, AND ERECTION OF REINFORCING STEEL,
UNLESS OTHERWISE NOTED, SHALL CONFORM TO ACI MNL-66, THE
CRSI, "MANUAL OF STANDARD PRACTICE," AND ACI 318.
3. REINFORCING STEEL SHALL BE CONTINUOUS ACROSS ALL
CONSTRUCTION JOINTS UNO.
4. REINFORCING STEEL SHALL NOT BE HEATED OR WELDED AND MUST
BE DRY AND FREE OF CONTAMINANTS SUCH AS RUST, DIRT,
GREASE, AND PROTECTIVE COATINGS.
5. ALL BAR SPLICES SHALL BE CLASS B TENSION SPLICES IN
ACCORDANCE WITH ACI 318.
REINFORCING STEEL FOR CONCRETE
1. THE GEOTECHNICAL ENGINEER SHALL REVIEW THE AGGREGATE BASE AND
VERIFY A MINIMUM MODULUS OF SUBGRADE REACTION OF 100 PCI HAS BEEN
ACHIEVED.
2. EXCAVATED / STRIPPED AREAS SHALL BE PROOF-ROLLED WITH APPROPRIATE
EQUIPMENT AS APPROVED BY THE GEOTECHNICAL ENGINEER. SOFT AREAS
SHALL BE REMOVED AND REPLACED WITH APPROVED BACKFILL AS DIRECTED BY
THE GEOTECHNICAL ENGINEER.
3. SAWED CONTROL JOINTS SHALL BE CUT AS SOON AS SLAB CAN BE WALKED ON,
BUT STARTED NO LATER THAN 8 HOURS AFTER POURING. CONTROL JOINTS
SHALL BE COMPLETED NO LATER THAN 16 HOURS AFTER POURING. THESE TIME
LIMITS SHALL APPLY REGARDLESS OF THE TIME OF DAY. AN EARLY ENTRY DRY
CUT SAW SUCH AS THE SOFF-CUT SYSTEM SHALL BE USED.
4. ADEQUATE MEASURE TO PREVENT PLASTIC SHRINKAGE OF SLAB SHALL BE
TAKEN BY THE CONTRACTOR AS OUTLINED IN ACI 302.1R.
SLAB ON GRADE
1. CONCRETE MASONRY UNITS (CMU) SHALL CONFORM TO ASTM C90 NORMAL
WEIGHT HOLLOW LOAD BEARING BLOCK UNITS. FIRE-RATED CMU SHALL BE
PROVIDED WHERE NOTED ON THE ARCHITECTURAL DRAWINGS.
2. MORTAR SHALL CONFORM TO ASTM C270, TYPE S
3. HORIZONTAL JOINT REINFORCING SHALL BE W1.7 (9 GAGE), GALVANIZED,
LADDER TYPE SPACED AT 16" OC, PROVIDE MIN 8" LAP AT ALL SPLICE
LOCATIONS.
4. COMPRESSIVE STRENGTH OF CONCRETE MASONRY AS DEFINED IN THE
TMS 602. SPECIFICATION SHALL BE f'm = 2,000 PSI MINIMUM AT 28 DAYS.
5. ALL CORES CONTAINING REINFORCING SHALL BE FULLY GROUTED. GROUT
SHALL CONFORM TO ASTM C476 WITH A 3000 PSI MINIMUM COMPRESSIVE
STRENGTH. GROUT SHALL HAVE A SLUMP OF 8" TO 10".
6. PROVIDE TWO GROUTED CORES ON EACH SIDE OF ALL DOOR AND
WINDOW OPENINGS. PROVIDE TWO GROUTED CORES ON EACH SIDE OF
ALL CORNERS AND AT EACH END CORE. REINFORCE EACH CORE WITH
ONE-BAR OF SIZE MATCHING WALL REINFORCING, UNO.
7. PROVIDE AN 8” BOND BEAM AT THE TOP OF ALL CMU WALLS AND
REINFORCE WITH TWO #5 CONTINUOUS REINFORCING BARS, UNO.
REINFORCED MASONRY
1. SHALLOW FOUNDATION DESIGN IS BASED ON THE ASSUMED DESIGN SOIL
BEARING PRESSURE PER APPLICABLE CODES.
2. THE FOUNDATIONS WERE DESIGNED BASED ON THE FOLLOWING NET
ALLOWABLE SOIL BEARING PRESSURES:
A. CONTINUOUS FOUNDATIONS 2,000 PSF
3. ALLOWABLE BEARING PRESSURES ARE BASED ON BEARING AGAINST FIRM,
UNDISTURBED SOIL AND OR ENGINEERED BACKFILL. WHERE UNACCEPTABLE
MATERIAL OCCURS, EXCAVATE AND REPLACE WITH ENGINEERED FILL AS
DIRECTED BY THE GEOTECHNICAL ENGINEER.
4. ALL FOUNDATION BEARING SURFACES SHALL BE REVIEWED BY THE
GEOTECHNICAL ENGINEER PRIOR TO STEEL OR CONCRETE PLACEMENT TO
ENSURE THAT THE BEARING SURFACES ARE CONSISTENT WITH THE ALLOWABLE
BEARING PRESSURES NOTED.
5. CONTRACTOR SHALL KEEP ALL FREE STANDING WATER OUT OF EXCAVATION.
CONTRACTOR SHALL PROVIDE DEWATERING MEASURES AS NECESSARY PRIOR
TO PLACING CONCRETE.
6. EXISTING SOIL WHICH IS DEEMED NON-USABLE BY THE GEOTECHNICAL
ENGINEER DUE TO FAILURE OF THE CONTRACTOR TO PROMPTLY DE-WATER THE
SITE SHALL BE REMOVED AND REPLACED WITH SUITABLE FILL AT THE
CONTRACTOR’S EXPENSE.
7. DESIGN OF TEMPORARY AND PERMANENT SHORING FOR EXCAVATIONS SHALL BE
THE RESPONSIBILITY OF THE CONTRACTOR.
8. FOR WALLS OR GRADE WALLS HAVING FILL ON EACH SIDE, PROCEED WITH
BACKFILLING OPERATIONS SIMULTANEOUSLY IN UNIFORM LIFTS. DIFFERENTIAL
ELEVATION OF TOP OF LIFTS BETWEEN EACH SIDE SHALL NOT EXCEED 18
INCHES.
FOUNDATIONS
ABBREVIATIONS
AB ANCHOR BOLT
ADDL ADDITIONAL
AFF ABOVE FINISH FLOOR
ALT ALTERNATE
APPROX APPROXIMATE, APPROXIMATELY
ARCH ARCHITECT, ARCHITECTURAL
B/ BOTTOM OF
BLDG BUILDING
BM BEAM
BO BOTTOM OF
BOD BASIS OF DESIGN
BOT BOTTOM
BP BASEPLATE
BRG BEARING
CC CENTER TO CENTER
CJ CONTROL JOINT, CONSTRUCTION JOINT
CL CENTER LINE
CLR CLEAR
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONC CONCRETE
CONT CONTINUOUS
CP COMPLETE PENETRATION
DIA DIAMETER
DIAG DIAGONAL
DL DEAD LOAD
DO DITTO
DWG DRAWING
EOS EDGE OF SLAB
EA EACH
EF EACH FACE
EL ELEVATION
EOR ENGINEER OF RECORD
EW EACH WAY
EXIST EXISTING
EXP EXPANSION
EXT EXTERIOR
FD FLOOR DRAIN
FDN FOUNDATION
FIN FLR FINISHED FLOOR
FTG FOOTING
GA GAUGE
GALV GALVANIZE, GALVANIZED
HDD HEADED
HORIZ HORIZONTAL
INT INTERIOR
JT JOINT
K KIPS
KSF KIPS PER SQUARE FOOT
KSI KIPS PER SQUARE INCH
L ANGLE
LG LONG
LL LIVE LOAD
LLV LONG LEG VERTICAL
LONG LONGITUDINAL
LVL LAMINATED VENEER LUMBER
LW LIGHT-WEIGHT
MANUF MANUFACTURER
MAS MASONRY
MATL MATERIAL
MAX MAXIMUM
MIN MINIMUM
MTL METAL
NIC NOT IN CONTRACT
NTS NOT TO SCALE
NW NORMAL-WEIGHT
OC ON CENTER
OPNG OPENING
OPP OPPOSITE
PAF POWDER ACTUATED FASTENER
PC PRECAST CONCRETE
PEJF PRE-MOLDED EXPANSION JOINT FILLER
PEMB PRE-ENGINEERED METAL BUILDING
PL PLATE
PREFAB PREFABRICATED
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PSL PARALLEL STRAND LUMBER
PT PRESERVATIVE TREATED
RD ROOF DRAIN
REF REFER, REFERENCE
REINF REINFORCING
REQD REQUIRED
RET RETAINING
SCHED SCHEDULE
SECT SECTION
SIM SIMILAR
SLV SHORT LEG VERTICAL
SOG SLAB-ON-GRADE
SPEC SPECIFICATIONS
STIFF STIFFENER
SQ SQUARE
SS STAINLESS STEEL
STD STANDARD
STL STEEL
SYM SYMMETRICAL
T&B TOP AND BOTTOM
T&G TONGUE AND GROOVE
T/ TOP OF
THDD THREADED
TO TOP OF
TRANS TRANSVERSE
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
VIF VERIFY IN FIELD
VERT VERTICAL
W/ WITH
W/O WITHOUT
WP WORKING POINT
WWR WELDED WIRE REINFORCING
TABLE 1704.7
REQUIRED VERIFICATION AND INSPECTION OF SOILS
VERIFICATION AND INSPECTION TASK
VERIFY MATERIALS BELOW SHALLOW FOUNDATIONS ARE
ADEQUATE TO ACHIEVE THE DESIGN BEARING CAPACITY.
VERIFY EXCAVATIONS ARE EXTENDED TO PROPER
DEPTH AND HAVE REACHED PROPER MATERIAL.
CONTINUOUS DURING
TASK LISTED
PERIODICALLY
DURING TASK LISTED
X
X
PERFORM CLASSFICATION AND TESTING OF
COMPACTED FILL MATERIALS.
- X
VERIFY USE OF PROPER MATERIALS, DENSITIES AND
LIFT THICKNESSES DURING PLACEMENT AND
COMPACTION OF COMPACTED FILL.
X -
PRIOR TO PLACEMENT OF COMPACTED FILL, OBSERVE
SUBGRADE AND VERIFY THAT SITE HAS BEEN
PREPARED PROPERLY.
- X
1.
2.
3.
4.
5.
TABLE 1704.5.1
LEVEL 1 REQUIRED VERIFICATION AND INSPECTION OF MASONRY CONSTRUCTION
CONTINUOUSVERIFICATION AND INSPECTION PERIODIC IBC SECTION
TMS 402/ACI
530/ASCE 5a
COMPLIANCE WITH REQUIRED INSPECTION PROVISIONS
OF THE CONSTRUCTION DOCUMENTS AND THE
APPROVED SUBMITTALS SHALL BE VERIFIED.
DURING CONSTRUCTION THE INSPECTION PROGRAM SHALL VERIFY:
- X - SEC. 1.2.2(E),
1.16.1
TMS 602/ACI
530.1/ASCE 6a
REFERENCE FOR CRITERIAFREQUENCY OF INSPECTION
- X - ART. 1.5-
VERIFICATION OF F'M AND F'AAC PRIOR TO CONSTRUCTION
EXCEPT WHERE SPECIFICALLY EXEMPTED BY THIS CODE.
- X - - ART. 1.4B
VERIFICATION OF SLUMP FLOW AND VSI AS DELIVERED TO
THE SITE FOR SELF-CONSOLIDATING GROUT.
X - - - ART. 1.5B.1.B.3
AS MASONRY CONSTRUCTION BEGINS, THE FOLLOWING SHALL BE VERIFIED TO ENSURE COMPLIANCE:
A. PROPORTIONS OF SITE-PREPARED MORTAR. -X- - ART. 2.6A
B. CONSTRUCTION OF MORTAR JOINTS. -X- - ART. 3.3B
C. LOCATION OF REINFORCEMENT AND CONNECTORS.
- X - - ART. 3.4, 3.6A
D. GRADE AND SIZE OF PRESTRESSING TENDONS AND
ANCHORAGES.
- X - - ART. 2.4B, 2.4H
A. SIZE AND LOCATION OF STRUCTURAL ELEMENTS.
B. TYPE, SIZE AND LOCATION OF ANCHORS, INCLUDING OTHER
DETAILS OF ANCHORAGE OF MASONRY TO STRUCTURAL
MEMBERS, FRAMES OR OTHER CONSTRUCTION.
-X- - ART. 3.3F
C. SPECIFIED SIZE, GRADE AND TYPE OF REINFORCEMENT.
- X - SEC. 1.15 ART. 2.4, 3.4
D. WELDING OF REINFORCING BARS. X - - SEC. 2.1.9.7.2,
3.3.3.4(B)
E. PREPARATION, CONSTRUCTION AND PROTECTION OF MASONRY
DURING COLD WEATHER (TEMPERATURE BELOW 40°F) OR HOT
WEATHER (TEMPERATURE ABOVE 90°F).
- X SEC. 2104.3,
2104.4
- ART. 1.8C,
1.8D
PRIOR TO GROUTING, THE FOLLOWING SHALL BE VERIFIED TO ENSURE COMPLIANCE:
A. GROUT SPACE IS CLEAN -X- - ART. 3.2D
B. PLACEMENT OF REINFORCEMENT AND CONNECTORS, AND
PRESTRESSING TENDONS AND ANCHORAGES.
- X - SEC. 1.13 ART. 3.4
C. PROPORTIONS OF SITE-PREPARED GROUT.
- X - - ART. 2.6B
D. CONSTRUCTION OF MORTAR JOINTS. -X- - ART. 3.3B
GROUT PLACEMENT SHALL BE VERIFIED TO ENSURE COMPLIANCE: --X - ART. 3.5
PREPARATION OF ANY REQUIRED GROUT SPECIMENS,
MORTAR SPECIMENS AND/OR PRISMS SHALL BE OBSERVED.
- X
SEC. 2105.2.2,
2105.3
- ART. 1.4
a. THE SPECIFIC STANDARDS REFERENCED ARE THOSE LISTED IN CHAPTER 35.
1.
2.
3.
4.
5.
6.
7.
8.
TABLE 1705.3
REQUIRED VERIFICATION AND INSPECTION OF CONCRETE CONSTRUCTION
CONTINUOUS
VERIFICATION AND
INSPECTION
PERIODIC
REFERENCED
STANDARDa
IBC
REFERENCE
1. INSPECTION OF REINFORCING STEEL, INCLUDING
PLACEMENT.
- X ACI 318: 3.5,
7.1-7.7
1910.4
AWS D1.4
ACI 318: 3.5.2
2. INSPECTION OF REINFORCING STEEL WELDING
IN ACCORDANCE WITH TABLE 1705.2.2, ITEM 2B.
- X ACI 318: Ch. 4, 5.2-5.4
3. VERIFYING USE OF REQUIRED DESIGN MIX.
4. AT THE TIME FRESH CONCRETE IS SAMPLED TO
FABRICATE SPECIMENS FOR STRENGTH TESTS,
PERFORM SLUMP AND AIR CONTENT TESTS, AND
DETERMINE THE TEMPERATURE OF THE CONCRETE.
X -
ASTM C 172
ASTM C 31
ACI 318: 5.6, 5.8
1910.10
X - ACI 318: 5.9, 5.10
1910.6, 1910.7, 1910.8
5. INSPECTION OF CONCRETE AND SHOTCRETE
PLACEMENT FOR PROPER APPLICATION
TECHNIQUES.
- X ACI 318: 5.11-5.13 1910.9
6. INSPECTION FOR MAINTENANCE OF SPECIFIED
CURING TEMPERATURE AND TECHNIQUES.
1904.2, 1910.2, 1913.3
BAR SIZE
CMU TYPE
8" CMU
12" CMU
#3
MINIMUM LAP SPLICE LENGTH SCHEDULE FOR CONCRETE
MASONRY UNITS (CMU)
#4 #5 #6 #7 #8 #9
19" 25" 31" 57" 79" 112" 146"
19" 25" 31" 52" 61" 75" 90"
BAR SIZE
USE
FOOTING
WALL
#3
MINIMUM LAP SPLICE LENGTH SCHEDULE FOR CONCRETE
(f'c = 3000 PSI)
#4 #5 #6 #7 #8
17" 22" 28" 33" 48" 55"
22" 29" 36" 43" 63" 72"
1. GENERAL NOTES AND TYPICAL DETAILS DESCRIBE GENERAL CRITERIA
APPLICABLE TO ALL SIMILAR CONDITIONS THROUGHOUT THE PROJECT
REGARDLESS OF WHETHER OR NOT THEY ARE SPECIFICALLY REFERENCED
IN THE PLANS OR DETAILS.
2. DO NOT SCALE DRAWINGS. IF DIMENSIONS ARE IN QUESTION, THE
CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING CLARIFICATION FROM
THE STRUCTURAL ENGINEER BEFORE CONTINUING WITH CONSTRUCTION.
3. CONTRACTOR SHALL COORDINATE THE STRUCTURAL DOCUMENTS WITH THE
ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING, FIRE PROTECTION
AND CIVIL DOCUMENTS. ARCHITECT/STRUCTURAL ENGINEER SHALL BE
NOTIFIED OF ANY DISCREPANCY.
4. THE CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR COMPLIANCE
WITH THE CONTRACT DOCUMENTS, FOR DIMENSIONS TO BE CONFIRMED AT
THE JOBSITE, FOR FABRICATION PROCESSES, AND FOR THE MEANS,
METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES OF
CONSTRUCTION.
5. NO SUBSTITUTIONS OF MATERIAL WILL BE ALLOWED WITHOUT WRITTEN
PERMISSION FROM THE ENGINEER.
6. THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS, MILL CERTIFICATES, AND
PRODUCT DATA FOR ALL MATERIALS AND PRODUCTS SHOWN IN THE
CONSTRUCTION DOCUMENTS, INCLUDING BUT NOT LIMITED TO, CONCRETE
MIX DESIGNS, STEEL REINFORCEMENT, STRUCTURAL STEEL, AND CAST-IN-
PLACE AND POST-INSTALLED ANCHORS. THE SHOP DRAWINGS SHALL
INCLUDE BOTH FABRICATION AND ERECTION DRAWINGS AND SHALL CONTAIN
PLANS, ELEVATIONS, AND DETAILS. REPRODUCTION OF THE CONSTRUCTION
DRAWINGS IS NOT AN ACCEPTABLE SHOP DRAWING SUBMITTAL.
7. SHOP DRAWINGS SHALL NOT BE REVIEWED FOR APPROVAL UNLESS
CHECKED BY THE FABRICATOR AND APPROVED BY THE CONTRACTOR.
REVIEW OF THE SHOP DRAWINGS BY THE ENGINEER DOES NOT ELIMINATE
THE CONTRACTOR'S RESPONSIBILITY TO COMPLY WITH ALL REQUIREMENTS
SET FORTH IN THE CONSTRUCTION DOCUMENTS.
8. CONTRACTOR SHALL COMPLY WITH LOCAL, STATE, FEDERAL AND OWNERS
SAFETY REGULATIONS WHILE WORKING. STRUCTURAL ENGINEER DOES NOT
ASSUME ANY RESPONSIBILITY FOR CONSTRUCTION SITE SAFETY.
9. CONTRACTOR SHALL REFER TO THE PROJECT SPECIFICATIONS FOR
ADDITIONAL REQUIREMENTS
10. VERIFY ALL EXISTING CONDITIONS, DIMENSIONS, AND ELEVATIONS BEFORE
STARTING WORK. NOTIFY STRUCTURAL ENGINEER OF ANY DISCREPANCY.
NOTIFY STRUCTURAL ENGINEER IN WRITING OF CONDITIONS ENCOUNTERED
IN THE FIELD CONTRADICTORY TO THOSE SHOWN ON THE STRUCTURAL
CONTRACT DOCUMENTS.
MISCELLANEOUS
WALL ZONE
EFFECTIVE WIND AREA (SF)
10 SF
20 SF
IBC 2018 ASCE 7-16 COMPONENTS AND CLADDING LOADS (PSF)
-32.6 -38.3
-31.6 -36.3
50 SF -30.2 -33.6
100 SF -29.2 -31.6
200 SF -28.2 -29.5
500 SF -26.9 -26.9
NOTES:
1. WALL CORNER ZONE WIDTH:
2. PLUS AND MINUS SIGNS SIGNIFY PRESSURES ACTING TOWARD
AND AWAY FROM THE SURFACES, RESPECTIVELY.
3. PRESSURES SHOWN IN TABLE ARE VULT, STRENGTH LEVEL
(LRFD).
a = 3 ft
T h e C o rn e rs
P a rk w a y
S u it e
P e a c h tr e e C o rn e rs
G e o rg ia
P h o n e
.5
.9
Copyright 2024, Barge Design Solutions, Inc. ALL RIGHTS RESERVED
T im e
D a te
SHEET:
FILE NO.
F ile
R E
V
IS
IO
N
I N
F O
R M
A T
IO
N
D ra w in g
D is c ip lin e S o rt
/1
/2
:5 :0
P
M
C
U s e rs
\K G
P e te rs \D o c u m e n ts
\3 T
U C
K a S v k a th le e n .p e te rs Y
Z
E .r v t
G E
N E
R A
L N
O T
E S
A N
D S
C H
E D
U L E
S
S0.01
C
IT
Y O
F T
U C
K E
R
T U
C K
E R
D
E K
A L
B C
O U
N T
Y
G E
O R
G
IA
3808804
S
T A
V E
C O
M P
A C
T O
R F
A C
IL
IT
Y
S .0
G E
N E
R A
L N
O T
E S
A N
D S
C H
E D
U L E
S
R E
V
D R
C H
K D
A T
E
D E
S C
R
IP
T
IO
N
K
P Z
R
-0
-2
D R
A F
T
K
P Z
R
-2
-2
F O
R C
O N
S T
R U
C T
IO
N
/8
GROUT
FILLED
SEE SCHED
FOR REINF
LINTEL SCHEDULE
WIDTH OF
OPENING
CMU
SIZE
TYPE
TOP
REINFORCING
BOTTOM
REINFORCING
STIRRUPS
<4'-0" 8" A (2) #5
TYPE A
WIDTH
WALL
LINTEL NOTES:
1. ALL BOND BEAM LINTELS SHALL BE CAST IN PLACE.
2. CMU LINTELS TO HAVE 8" MINIMUM BEARING EACH END.
LOOSE BRICK STEEL LINTELS SHALL HAVE 6" MINIMUM
BEARING EACH END.
3. VERTICAL WALL REINFORCEMENT SHALL BE CONTINUOUS
THROUGH LINTEL.
4. CONTROL JOINT SHALL NOT BE LOCATED WITHIN BEARING.
5. WHEN THE DISTANCE BETWEEN TWO ADJACENT OPENINGS
IS LESS THAN THE WIDTH OF EITHER OPENING, THE LINTEL
INDICATED SHALL BE CONTINUOUS OVER BOTH OPENINGS.
6. SEE ARCHITECTURAL FOR HEIGHT AND WIDTH OF
MASONRY OPENINGS.
C L R
/2
OPENING WIDTH
0'-0" TO 4'-0"
ANGLE SIZE
L3 1/2x3 1/2x1/4
REMARKS
LOOSE BRICK LINTEL SCHEDULE
8" CMU REINF. W/#5 @ 16"
O.C. IN GROUT FILLED
CELL - EXTEND INTO
BOND BEAM AT TOP OF
WALL
8" BOND BEAM W/(2) #5
CONT. IN GROUT FILL
(4) #5 CONT (EQ SPA,
TOP & BOTTOM)
#5 @ 9" O.C. (TOP &
BOTTOM)
T/SLAB
0'-0"
T/WALL
8'-0" AFF
T/FOOTING
-1'-4"
T/SIDEWALK
SEE CIVIL
TYP.
3" CLR
T Y
P
C L R
DOWELS TO MATCH SIZE AND
SPACING OF VERTICAL WALL
REINFORCING
1'-0"
CONCRETE SLAB ON
GRADE - SEE
FOUNDATION PLAN
3'-6"
GROUT SOLID
BELOW GRADE
EXTERIOR VENEER
(ATTACH TO CMU
W/VENEER ANCHORS AT
16" O.C.)
1/2" PJF w/ EXTERIOR GRADE
SEALANT
1/2" PJF w/ EXTERIOR
GRADE SEALANT
PREFINISHED METAL
COPING - MATCH COLOR
OF GATE
NOTES:
1. CMU IS TO BE PAINTED
(EXTERIOR AND INTERIOR
FACES OF CMU).
2. BRICK VENEER IS TO MATCH
THE TUCKER TOWN GREEN
PROJECT IN STYLE, COLOR,
AND MATERIAL.
26'-8"
NOTES:
1. SEE CIVIL FOR ORIENTATION AND LOCATION OF COMPACTOR.
2. GENERAL CONTRACTOR TO VERIFY WALL DIMENSIONS WITH CIVIL PRIOR TO FABRICATION.
3. TOP OF FOOTING ELEVATION = -1'-4" (BELOW TOP OF SLAB), U.N.O.
4. 6" NORMAL WEIGHT CONCRETE (f'c = 4000 PSI) REINFORCED WITH #5 @ 12" O.C. E.W. AT SLAB
MID-DEPTH OVER 4" GRANULAR BASE ON COMPACTED SUBGRADE. PROVIDE LIGHT BROOM
FINISH.
5. SEE CIVIL FOR QUANTITY AND LOCATION OF 6" BOLLARDS. SEE FOR DETAIL.
6. GATE POSTS TO BE SLEEVED/EMBEDDED IN CONCRETE, SIMILAR TO DETAIL . GATE
AND HARDWARE TO BE DESIGNED AND PROVIDED BY MFR - HSS 3X3X1/4 (MIN) FRAME WITH
DIAGONAL HSS3X3X1/4 (MIN.) BRACE. PROVIDE 3/4" SLEEVE IN TURNDOWN SLAB AT CANE
BOLT AT MIDDLE OF GATE PER MFR AND AT OPEN POSITION OF GATE.
7. PROVIDE 8" DEEP BOND BEAM LINTEL OVER DOOR OPENING - SEE DETAIL .
8. PROVIDE LOOSE STEEL BRICK LINTEL OVER DOOR OPENING - SEE DETAIL .
9. GATE:
A. GATE DESIGN TO BE APPROVED BY THE CITY PRIOR TO FABRICATION OR INSTALLATION.
TOP OF GATE TO BE 4" BELOW TOP OF WALL. BOTTOM OF GATE TO BE 4" ABOVE TOP OF
SLAB.
B. GATE TO BE DESIGNED AND INSTALLED IN ACCORDANCE WITH CITY APPROVED VENDOR
REQUIREMENTS.
C. GATE OPENING IS TO BE 12'-0" WIDE (MIN.) IN OPEN POSITION.
D. PROVIDE 3/4" DIAMETER CANE BOLTS AND SLEEVES IN CONCRETE AT BOTH CLOSED AND
OPEN POSITIONS - SEE NOTE 6 ABOVE.
E. GATE TO BE PAINTED PER CITY REQUIREMENTS.
F. SEE NOTE 6 ABOVE FOR ADDITIONAL REQUIREMENTS.
10'-0"
4'-8" 3'-10"
(2) REINF/GROUTED CELLS,
TYP AT WALL END - SEE
(3) REINF/GROUTED CELLS,
TYP AT WALL CORNER - SEE
6" BOLLARD - SEE
NOTE 5
NOTE 4
GATE POST - SEE
NOTE 6
(1) REINF/GROUTED CELL,
TYP AT EACH SIDE OF
OPNG - SEE
S1.01
S1.01
S1.01
S1.014
S3.01
3/4" SLEEVE FOR CANE BOLT
(AT OPEN AND CLOSED
POSITIONS OF GATE)
SLAB CONTROL
JOINTS, SEE
/9 S3.01
/9 S3.01
/1 S1.01
/2 S1.01
/7 S3.01 /1 S3.01
/7 S3.01
/7 S3.01
C L
R
2'-0"
T/CMU = (+)8'-0" (TYP)
8" CMU REINF. W/#5 @ 16"
O.C. IN GROUT FILLED
CELL - EXTEND INTO
BOND BEAM AT TOP OF
WALL
8" BOND BEAM W/(2) #5
CONT. IN GROUT FILL
(5) #5 CONT (EQ SPA,
TOP & BOTTOM)
#5 @ 9" O.C. (TOP &
BOTTOM)
T/SLAB
0'-0"
T/WALL
8'-0" AFF
T/FOOTING
-1'-4"
T/SIDEWALK
SEE CIVIL
TYP.
3" CLR.
T Y
P
C L R
DOWELS TO MATCH SIZE AND
SPACING OF VERTICAL WALL
REINFORCING
1'-0"
CONCRETE SLAB ON
GRADE - SEE
FOUNDATION PLAN
4'-3"
GROUT SOLID BELOW GRADE
1/2" PJF w/ EXTERIOR GRADE
SEALANT
EXTERIOR VENEER
(ATTACH TO CMU
W/VENEER ANCHORS AT
16" O.C.)
1/2" PJF w/ EXTERIOR
GRADE SEALANT
NOTES:
1. CMU IS TO BE PAINTED
(EXTERIOR AND INTERIOR
FACES OF CMU).
2. BRICK VENEER IS TO MATCH
THE TUCKER TOWN GREEN
PROJECT IN STYLE, COLOR,
AND MATERIAL.
PREFINISHED METAL
COPING - MATCH COLOR
OF GATE
(4) #5 CONT (EQ SPA,
TOP & BOTTOM)
#5 @ 9" O.C. (TOP &
BOTTOM)
T/SLAB
0'-0"
T/FOOTING
-1'-4"
T/SIDEWALK
SEE CIVIL
TYP.
3" CLR
T Y
P
C L R
#5 @ 16" O.C. (2 MIN.)
CONCRETE SLAB ON
GRADE - SEE
FOUNDATION PLAN
3'-6"
GROUT SOLID BELOW GRADE
8" CMU
CMU BEYOND (HM DOOR IN HM
FRAME AT OPNG)
3/4" SLOPED THRESHOLD
T h e C o rn e rs
P a rk w a y
S u it e
P e a c h tr e e C o rn e rs
G e o rg ia
P h o n e
.5
.9 im e
D a te
SHEET:
FILE NO.
F ile
R E
V
IS
IO
N
I N
F O
R M
A T
IO
N
D ra w in g
D is c ip lin e S o rt
/1
/2
:5 :0
P
M
C
U s e rs
\K G
P e te rs \D o c u m e n ts
\3 T
U C
K a S v k a th le e n .p e te rs Y
Z
E .r v t
F O
U N
D A
T
IO
N P
L A
N A
N D
S E
C T
IO
N
S
S1.01
C
IT
Y O
F T
U C
K E
R
T U
C K
E R
D
E K
A L
B C
O U
N T
Y
G E
O R
G
IA
3808804
S
T A
V E
C O
M P
A C
T O
R F
A C
IL
IT
Y
S .0
F O
U N
D A
T
IO
N P
L A
N A
N D
S E
C T
IO
N
S
S1.01
SCALE: 3/4" = 1'-0"
1 CMU LINTEL SCHEDULE
S1.01
SCA…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .