PLANS SPEC BID 2988 - 20417.pdf
PDF 9 MB Posted
- Attached to
- PW Prequal Bid -2988-Relay of Water Mains in Devereaux Ave from Walker St to Gillispie St
- Solicitation number
- B2728426
- Issued by
- Pennsylvania
About this file
Water Main Relay Project - Plans and Specifications Summary
This is a comprehensive plans and specifications document for the City of Philadelphia Water Department's Water Main Relay Project (Work No. W-20417-DG), prepared by design engineer Zachary Young and dated December 26, 2026. The project encompasses the installation of new ductile iron water mains and associated appurtenances across multiple Philadelphia streets, including Devereaux Avenue, Walker Street, Cottage Street, Gillespie Street, Jackson Street, Hale Street, Ditman Street, and Marsden Street. The project involves the installation of approximately 7,120 linear feet of water pipe in various sizes (6-inch through 36-inch diameter), along with fire hydrants, valves, valve boxes, tees, bends, reducers, sleeves, caps, mechanical couplings, and specialized fittings. The specifications detail extensive underground utility coordination, including interaction with existing water mains, sewer lines, gas infrastructure, and telecommunications conduits. The document includes 24 sheets of detailed plans with cross-sectional profiles, bills of materials for each project section, and transmission main crossing details.
The project requires strict adherence to Pennsylvania Act 287 of 1974 (Underground Utility Line Protection Act) and Act 121 of 2008, with contractors mandated to contact the Pennsylvania One Call System at least three days prior to excavation. Payment will be made only for the actual amount of pipe and appurtenances installed, with bills of materials provided for contractor convenience. The contractor must maintain minimum clearances of six inches between all underground structures and new water mains, and eighteen inches of vertical clearance when crossing active water transmission mains sixteen inches and larger. Extensive corrosion control provisions are detailed across sheets W-13 through W-24, including magnesium anode installation at eighteen-foot intervals, test station placement, thermite welding of bond wires, and bitumastic coating applications. The document specifies numerous technical requirements for existing main cuts and plugging, fire hydrant relocation approval procedures, and comprehensive utility notification and coordination procedures.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Seller_Prequal_Checklist 2020.~17.pdf | ||
| AD 2988~1.pdf | ||
| SPEC BID 2988 - 20417 Final~2.pdf | ||
| Prequal. Questionnaire Public Works~20.pdf | ||
| Consent Authorization Form.~25.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
36" 24"
24"
24" 24"
.02712
.02712
.0
.0
.02712
.02712
.0 06 .0
.02712
.02712.01137
.01056
.0
.0
.0
.0
DEVEREAUX AVENUE
PARKING
NO PARKING
PARKING
NO PARKING
W A
LK
ER
S T.
PA
RK
IN
G
NO PARKING
PA
RK
IN
G
NO PARKING
A
LG
A R
D S
T.
PA
RK
IN
G
NO PARKING
PA
RK
IN
G
NO PARKING
A
A
G
V
V G
W
TS
V W V W
G
V G
G
W V V
G G W W W V
X X
X X
X
W
G W
G G W
TS
W W
V V
TS
V
V W
G G
W
V V
TS
2 Sty. Brick Row Houses
2 Sty. Brick Row Houses
2 Sty. Brick Row Houses
St y.
B ric k
Ro w
H ou se s
2 Sty. Brick Row Houses
2 Sty. Brick Row Houses
C/R
C/ R
V V
.6
.8
4CI
#3
#3
#4
#3
2 1
1 1
3'
-6
'-0
6'
-0
6' -5
3'-0"
2'-0" 13'-0"
6'-0"
'-6
3' -6
6' -0
1' -3
'-0
1'-6" 8'-0" 11'-4"
4'-6"
7' -6
2' -0
'-0
4' -6
8'
-0
6' -6
'-6
6' -6
4'
-6
7' -6
2'
-0
4' -6
6'-0"
10'-0"
4'-0"
5' -0
'-0
6' -6
'-6
3' -6
2'
-0
4' -6
8' -0
6'
-0
9'-10"
Sewer 21" Dia. RCP, 9'-9"± Cov.
Water 8", 4'-0" Cov.
Verizon 9" x 9", Unk. Cov.
Gas 6", 3'-0" Cov.
Sewer 12" Vent
Gas 6", 4'-6" Cov.
Water 6", 3'-0" Cov.
Gas 12", 4'-0" Cov.
Gas 12" H.P., 3'-6" Cov.
Water 48", 3'-0" Cov.
Verizon 9" x 18", 3'-0" Cov.
Water 30", 2'-3" Cov.
Verizon 9" x 9", 3'-9" Cov.
Sewer 3'-6" x 2'-4" Br., 10'-3"± Cov.
Gas 6", 4'-0" Cov.
Verizon 9" x 9", 3'-9" Cov.
Sewer 2'-3" x 1'-6" Br., 10'-10"± Cov.
Water 6", 3'-1" Cov.
Gas 6", 3'-0" Cov.
Verizon 5" x 9", 3'-9" Cov. Water 6", 4'-0" Cov.
Gas 8", 3'-0" Cov.
Gas 12", 4'-1" Cov.
PROP. 8" D.I. WATER MAIN, 4'-0" COVERGas 12", 5'-3" Cov.
Gas 12", 8'-0" Cov.
Gas 6", 3'-2" Cov.
Water 6", 4'-0" Cov.
(TO BE ABAND.)
Gas 6", 3'-6" Cov.
'-6
Sewer 18" Dia. RCP 9'-7"± Cov.
Water 8", 4'-0" Cov.
Gas 8", 1'-9" Cov.
Sewer 12" Vent
Gas 8", 6'-8" Cov.
Sewer 2'-3" x 1'-6" Br., 10'-2"± Cov.
Sewer 10" Dia. VCP, Unk. Cov.
Water 6", 4'-0" Cov.
Sewer 18" Dia. RCP, 11'-0"± Cov.
Gas 6", 4'-5" Cov.
'-6
5'-0"
4'-0" 5'-0"
11'-0"
(TO BE ABAND.)
Verizon 10" x 10", 3'-9" Cov.
Sewer 3'-6" x 2'-4" Br.
11'-0"± Cov.
(TO BE ABAND. AND FILLED )
Gas 6", 2'-9" Cov.
3' -6
Verizon 10" x 10", 3'-0" Cov.
6' -0
Gas 12", 3'-6" Cov.
Gas 12", 2'-4" Cov.
Verizon 10" x 10", 3'-9" Cov.
'-6
Water 30", 2'-3" Cov.
PROP. 8" D.I. WATER MAIN
DEFLECT PIPE AS NECESSARY
'-6
(TO BE FILLED AND ABAND.)
4' -0
5'-0" 8'-0"
SECTION A - A
PROPOSED 8" WATER MAIN, 4'-0" COV.
10'-6"
REMOVE FRAME & COVER - SEE SPEC'S.
REMOVE FIRE HYDRANT - SEE SPEC'S.
REMOVE PIPE AND/OR FITTING & RECONNECT.
4 ROTATE FITTINGS AS REQUIRED.
5 REMOVE & RETURN VALVE - SEE SPEC'S.
NOTES:
1. EXISTING WATER MAINS SHALL BE CUT & PLUGGED AS
APPROVED BY THE CITY ENGINEER.
2. THE CONTRACTOR SHALL MAINTAIN A MINIMUM 6-INCH
CLEARANCE BETWEEN ALL UNDERGROUND STRUCTURES AND
THE NEW WATER MAINS.
3. BILLS OF MATERIAL AND PIPE TOTALS ARE FOR THE
CONVENIENCE OF THE CONTRACTOR ONLY AND PAYMENT WILL
BE MADE ONLY FOR THE ACTUAL AMOUNT OF PIPE AND
APPURTENANCES INSTALLED.
4. FIRE HYDRANTS SHALL NOT BE CONSTRUCTED OR RELOCATED
UNTIL SUCH LOCATIONS HAVE BEEN APPROVED BY THE WATER
DEPARTMENT CONSTRUCTION DIVISION IN THE FIELD.
5. ALL DISTANCES SHOWN ARE IN DISTRICT STANDARD
MEASUREMENTS
BILL OF MATERIALS
4 STD. FIRE HYDRANT W/CCL
11 STD. 7" VALVE BOX(ES)
7 8" VALVE(S)
4 6" VALVE(S)
5 8"X8" TEE(S)
4 8"X6" HYDRANT ANCHOR TEE(S)
18 8" 1/8 BENDS (10 VERTICAL)
6 6" 1/8 BENDS (0 VERTICAL)
3 8"X6" REDUCER(S)
2 8" SLEEVE(S)
3 6" SLEEVE(S)
PIPE TOTALS (ALL SHEETS)
70' ± 30" DUCTILE IRON WATER MAIN
740' ± 24" DUCTILE IRON WATER MAIN
1665' ± 12" DUCTILE IRON PIPE MAIN
3770' ± 8" DUCTILE IRON PIPE MAIN
275' ± 6" DUCTILE IRON PIPE MAIN
PIPE TOTALS (THIS SHEET)
875' ± 8" DUCTILE IRON WATER MAIN
80' ± 6" DUCTILE IRON WATER MAIN
APPROVED
CHIEF, DESIGN BRANCH, ENGINEERING DIVISION
APPROVED
APPROVED
DEPUTY COMMISSIONER - ENGINEERING
WATER COMMISSIONER
DRAWN BY
PROJECT ENGR.
SUPERVISOR DATE
WORK NO.
SHEET NO. OF
CITY OF PHILADELPHIA
WATER DEPARTMENT
WATER MAIN RELAY PROJECT
PURSUANT TO THE REQUIREMENTS OF PENNSYLVANIA ACT 287 OF 1974 (THE UNDERGROUND UTILITY
LINE PROTECTION ACT), AS AMENDED BY PA ACT 121 OF 2008, THE CONTRACTOR
SHALL CONTACT THE PENNSYLVANIA ONE CALL SYSTEM AT 1-800-242-1776, AT LEAST
3 DAYS PRIOR TO EXCAVATION.
HIGHWAY DISTRICT NO. WARD NO.
SURVEY DISTRICT NO.
ONE CALL SERIAL NO.
NOTICE:
WATER PLATE NO.
FROM
SCALES:
PLAN 1" = 20'
AND AS NOTED
W-1
GPIS NO.
g\ ap pd at a\ lo ca l\t em p\
Ac Pu bl ish
_1
\W at er
Sh ee ts .d w g\
W -1
B y:
Z
AC
H
AR
Y.
YO
U
N G
/6
/2
CS
V
1.
SHEETS
W-20417-DG
ZACHARY YOUNG
ZACHARY YOUNG 12/26/26
12/26/26
DEVEREAUX AVENUE
WALKER STREET TO ALGARD STREET
20240121522,20240121523,20240121541
5 55
G2024-00104
M A
TC
H
LI
N
E
SE
E
SH
EE
T
W -2A
A
PROP. 8" D.I. WATER MAIN
(SEE CROSSING DETAIL SHEET W-12)
Gas 6", 3'-0" Cov.
Water 6", 4'-0" Cov.
(TO BE ABAND.)
Sewer 4'-6" x 3'-0" Br., 10'-2" Cov.
Gas 12" HP, 3'-6" Cov.
Water 48", 3'-0" Cov.
Verizon 10" x 10", 2'-6" Cov.
Water 30", 2'-3" Cov.
Water 6", 4'-0" Cov.
Verizon 9" x 9", 3'-9" Cov.
Gas 12", 2'-8" Cov.
(TO BE FILLED AND ABAND.)
(TO BE ABAND.)
10/30/2026
William.Dobbins Stamp zachary.young Text Box
FINAL DESIGN ONE CALL NO.
zachary.young Line zachary.young Text Box 20263060727, 20263060728, 20263060736, 20263060737
2 Sty. Brick Row
Houses
2 Sty. Brick Row
Houses
24" 24" 12"
.0
.0
.00757
.008
.02712
.0
.0245
.0245
.0245
.0245
B
BD.E.
D.E.
V V
TS
TS
W V
W V
G
V
TS
G
G
12"
TS
G
G
WVWV
G
G
G
W W
W?V
G
G
W
V
V G
W
V G G
W W
V V G
G W V
W?
V V
W W W V V
G
V W
V W G
VW
V W
GGGGGGGGGG
G
G V V
W
W
W
WW
V
V V?
W
V W
W W V V
W V
WVV W
W
VWVWV
W
V
W
VWV
VV
WWV W
St y.
B ric k Ro w H ou se s
St y.
B ric k
Ro w
H ou se s
2 Sty. Brick Row Houses
2 Sty. Brick Row Houses
#3
3 1
A.V.
12'-6" 6'-6"
3'-6" 8'-0" 6'-0" 7'-6" 4'-6"
17'-0"
2'-0" 5'-6"
3'-6"
3'-0"
3'-0" 6'-0"
3'-0"
13'-0"
8'-0"
13'-0"
8'-0"
8'-0"
5'-4"
12'-6" 6'-6"
3'-6" 4'-6"
17'-0" 6'-0"
Sew er 2'-3" x 1'-6" Br., 10'-2"± Cov.
Sew er 18" Dia. RCP, 11'-0"± Cov.
10'-6"
11'-0" 8'-0"
Verizon 5"x 5", 2'-8" Cov. & 2-4", Unk. Cov.
Verizon 5"x 9", Unk. Cov.
Gas 6",2'-2" Cov.
Gas 6",2'-2" Cov.
Gas 6",2'-6" Cov.
11'-0"
Sewer 18" Dia. RCP, 9'-6"± Cov.
Water 12", 4'-0" Cov.
Gas 6",2'-6" Cov.
Sewer 18" Dia. RCP, 9'-9"± Cov.
7'-0"
(TO BE ABAND. )
4'-6"
11'-0"
12'-10"
10'-0"
10'-6"
(SEE SPEC)
6'-0"
6'-0"
SECTION B - B
REMOVE FRAME & COVER - SEE SPEC'S.
REMOVE FIRE HYDRANT - SEE SPEC'S.
REMOVE PIPE AND/OR FITTING & RECONNECT.
4 ROTATE FITTINGS AS REQUIRED.
5 REMOVE & RETURN VALVE - SEE SPEC'S.
NOTES:
1. EXISTING WATER MAINS SHALL BE CUT & PLUGGED AS
APPROVED BY THE CITY ENGINEER.
2. THE CONTRACTOR SHALL MAINTAIN A MINIMUM 6-INCH
CLEARANCE BETWEEN ALL UNDERGROUND STRUCTURES AND
THE NEW WATER MAINS.
3. BILLS OF MATERIAL AND PIPE TOTALS ARE FOR THE
CONVENIENCE OF THE CONTRACTOR ONLY AND PAYMENT WILL
BE MADE ONLY FOR THE ACTUAL AMOUNT OF PIPE AND
APPURTENANCES INSTALLED.
4. FIRE HYDRANTS SHALL NOT BE CONSTRUCTED OR RELOCATED
UNTIL SUCH LOCATIONS HAVE BEEN APPROVED BY THE WATER
DEPARTMENT CONSTRUCTION DIVISION IN THE FIELD.
5. ALL DISTANCES SHOWN ARE IN DISTRICT STANDARD
MEASUREMENTS
BILL OF MATERIALS
2 STD. FIRE HYDRANT W/CCL
10 STD. 7" VALVE BOX(ES)
1 24" VALVE(S)
5 12" VALVE(S)
2 8" VALVE(S)
2 6" VALVE(S)
1 12"X6" HYDRANT ANCHOR TEE(S)
1 8"X6" HYDRANT ANCHOR TEE(S)
1 24"X12" TEE(S)
3 12"X12" TEE(S)
1 12"X8" TEE(S)
8 24" 1/8 BENDS (6 VERTICAL)
26 12" 1/8 BENDS (21 VERTICAL)
6 8" 1/8 BENDS (4 VERTICAL)
1 30"X24" REDUCER(S)
2 12"X8" REDUCER(S)
1 12" SLEEVE(S)
1 24" CAP(S)
2 12" CAP(S)
1 30"
MECHANICAL
COUPLING(S)
1 24" 2" MANUAL AIR VALVE
PIPE TOTALS (THIS SHEET)
15' ± 30" DUCTILE IRON WATER MAIN
430' ± 24" DUCTILE IRON WATER MAIN
530' ± 12" DUCTILE IRON WATER MAIN
235' ± 8" DUCTILE IRON WATER MAIN
25' ± 6" DUCTILE IRON WATER MAIN
APPROVED
CHIEF, DESIGN BRANCH, ENGINEERING DIVISION
DRAWN BY
PROJECT ENGR.
SUPERVISOR DATE
WORK NO.
SHEET NO. OF
CITY OF PHILADELPHIA
WATER DEPARTMENT
WATER MAIN RELAY PROJECT
PURSUANT TO THE REQUIREMENTS OF PENNSYLVANIA ACT 287 OF 1974 (THE UNDERGROUND UTILITY
LINE PROTECTION ACT), AS AMENDED BY PA ACT 121 OF 2008, THE CONTRACTOR
SHALL CONTACT THE PENNSYLVANIA ONE CALL SYSTEM AT 1-800-242-1776, AT LEAST
3 DAYS PRIOR TO EXCAVATION.
HIGHWAY DISTRICT NO. WARD NO.
SURVEY DISTRICT NO.
ONE CALL SERIAL NO.
NOTICE:
WATER PLATE NO.
FROM
SCALES:
PLAN 1" = 20'
AND AS NOTED
W-2
GPIS NO.
g\ ap pd at a\ lo ca l\t em p\
Ac Pu bl ish
_1
\W at er
Sh ee ts .d w g\
-2
Z
AC
H
AR
Y.
YO
U
N G
/6
/2
CS
V
1.
SHEETS
W-20417-DG
ZACHARY YOUNG
ZACHARY YOUNG 12/26/26
12/26/26
COTTAGE STREET
DEVEREAUX AVE. TO 260' WEST OF ROBBINS STREET(S.R. 1024)
20240121485
5 55
G2024-00104
MATCHLINE SEE SHEET W-1
AA
MATCHLINE SEE SHEET W-4
CC
M A
TC
H
LI
N
E
SE
E
SH
EE
T
W -3B
B
COTTAGE STREET
PARKING
NO PARKING
PARKING
NO PARKING
D
EV
ER
EA
U X
A
VE
PA
RK
IN
G
NO PARKING
PA
RK
IN
G
NO PARKING
PROP. 12" D.I. WATER MAIN
PROP. 30" CAP
DEFLECT AS NECESSARY
PROP. 24" D.I. WATER MAIN
(SEE PROFILE SHEET W-12)
PROP. 12" D.I. WATER MAIN
Verizon 5"x 5", Unk. Cov.
Sewer 18" Dia. RCP, 9'-2"± Cov.
Gas 6",2'-6" Cov.
PROP. 12" D.I. ROUND CONNECTION(SEE SPEC)
PROPOSED 12" CAP(SEE SPEC.)
District Boundary Control Valve (To Remain Closed)
Water 48", 3'-0" Cov.
Sewer 4'-6" x 3'-0" Br. 10'-2"± Cov.
(TO BE ABAND. )
Water 6", 4'-0" Cov.
Gas 12" HP , 3'-0" Cov.
Gas 6",3'-0" Cov.
PROP. 8" D.I. WATER MAIN, 4'-0" COVER
Gas 12" , 4'-2" Cov.
Gas 8" , 7'-0" Cov.
Water 30", 6'-7" Cov.
Verizon 18"x 10", 2'-6" Cov.
Water 6", 4'-0" Cov.
(TO BE ABAND.)
Sewer 3'-6" x 2'-4" Br., 10'-3"± Cov.
(TO BE REMOVED)
PROP. 24" D.I. WATER MAIN,
PROP. 8" D.I. WATER MAIN, 4'-0" COVER
PROP. 24" D.I. WATER MAIN
Water 30", 2'-6" Cov.
Verizon 5"x 5", Unk. Cov.
Sewer 10" Dia. VCP, 6'-2"± Cov.
Water 12", 3'-3" Cov.
Verizon 5"x 9", 2'-6" Cov.
Gas 6" , 4'-2" Cov.
PROP. DISTRICT BOUNDARY CONTROL
VALVE (TO REMAIN CLOSED)
Gas 12" HP , 3'-0" Cov.
Verizon 10"x 10", 2'-6" Cov.
Verizon 9"x 9", 3'-9" Cov.
Water 30", 2'-3" Cov.
Water 6", 4'-0" Cov.
(TO BE ABAND.)
(TO BE ABAND.)
PROP. 8" D.I. WATER MAIN, 4'-0" COVER
(TO BE FILLED AND ABAND.)
District Boundary Control Valve (To Remain Closed)
District Boundary Control Valve (To Remain Closed)
Sewer 4'-6" x 3'-0" Br., 10'-4"± Cov.
Gas 6" , 3'-6" Cov.
Gas 6" , Unk. Cov.
Sewer 12" Vent
Gas 6" , 3'-0" Cov.
Water 6", 4'-0" Cov.
Gas 12" HP, 3'-0" Cov.
(TO BE ABAND.)
Water 48", 2'-3" Cov.
Water 6", 4'-0" Cov.
(TO BE ABAND.)
PROP. 30" D.I. WATER MAIN
PROP. 2" MANUAL AIR VALVE W/CHAMBER
PROP. 12" D.I. WATER MAIN
Verizon 2 - 4", Unk. Cov.
333333
David.Weld Dtw w date Stamp zachary.young Text Box
FINAL DESIGN ONE CALL NO.
zachary.young Line zachary.young
20263060736, 20263060737, 20263060714, 20263060715
Row Houses
2 Sty. Brick Row Houses
X
X X
X X
12" 12" 12"
6"
6"
6"
11'-0"
.0245
.0245
.0
.0
.0
.0
.004
.004
G V W
V
V V W
G G
TS
V
V W
G
W W V W
V W
G V
W V
W V
W
G GG
V ? W
V
TS V
V W
G
W V
W W
V
G
W V
W
V G
W V W
V
G
TS W V
G
3"
TL
TL
TL
G
VW
V
WG
G
2 Sty. Brick Row Houses
2 Sty. Brick Row Houses
C
C
13'-0"
8'-0"
8'-0"
8'-0"
13'-0"
8'-0" 8'-0"
9'-2"
5'-0"
2'-6"
13'-0" 3'-5" 8'-6"
16'-0"
8'-0"
13'-0"
Gas 6",2'-1" Cov.
Sewer 18" Dia. RCP, 10'-8"± Cov.
13'-0" 3'-0" 8'-10"
Water 12", 4'-0" Cov.
Water 8", 4'-0" Cov.
Sewer 36" Dia. RCP, 9-6"± Cov.
8'-0"
5'-0"
8'-0"
Traffic Conduit, Unk. Size, Unk. Cov., Typ.
8'-0"
Gas 6",2'-6" Cov.
Gas 6",2'-1" Cov.
12" D.I. ROUND CONNECTION
PROP. 24" D.I. WATER MAIN,
(SEE CROSSING DETAIL
THIS SHEET)
PROP. 24" D.I. WATER MAIN,
6'-0" COV.
PROPOSED 24" WATER MAIN, 5'-0" COV.
(SEE PROFILE SHEET W-12)
PROPOSED 12" D.I. WATER MAIN, 4'-0" COV.
DEFLECT PIPE AS NECESSARY
6'-0"
PROPOSED ZAYO FIBEROPTIC 2",
AT GRADE
2'-0"
13'-0"
11'-0"
SECTION C - C
Gas 6",2'-6" Cov.
Water 12", 4'-0" Cov.
Sewer 18" Dia. RCP, 9'-11"± Cov.
Gas 6", 2'-3" Cov.
Gas 6", 1'-10" Cov.
Water 60" Steel, 4'-0" Cov.
Sewer 21" Dia. RCP, 10'-0"± Cov.
Water 24", 2'-6" Cov.
Water 12", 4'-0" Cov.
PROPOSED 8" D.I. WATER MAIN
(SEE CONTRACT W-20552-DG)
Gas 6", 2'-11" Cov.
Water 60" Steel, 3'-6" Cov.
Water 24", 2'-6" Cov.
Gas 6", 2'-2" Cov.
Sewer 21" Dia. RCP, 10'-4"± Cov.
Sewer 21" Dia. RCP, 10'-4"± Cov.
(TO BE ABAND. AND FILLED)
Gas 6", 2'-6" Cov.
Water 12", 4'-0" Cov.
(TO BE ABAND. )
REMOVE FRAME & COVER - SEE SPEC'S.
REMOVE FIRE HYDRANT - SEE SPEC'S.
REMOVE PIPE AND/OR FITTING & RECONNECT.
4 ROTATE FITTINGS AS REQUIRED.
5 REMOVE & RETURN VALVE - SEE SPEC'S.
NOTES:
1. EXISTING WATER MAINS SHALL BE CUT & PLUGGED AS
APPROVED BY THE CITY ENGINEER.
2. THE CONTRACTOR SHALL MAINTAIN A MINIMUM 6-INCH
CLEARANCE BETWEEN ALL UNDERGROUND STRUCTURES AND
THE NEW WATER MAINS.
3. BILLS OF MATERIAL AND PIPE TOTALS ARE FOR THE
CONVENIENCE OF THE CONTRACTOR ONLY AND PAYMENT WILL
BE MADE ONLY FOR THE ACTUAL AMOUNT OF PIPE AND
APPURTENANCES INSTALLED.
4. FIRE HYDRANTS SHALL NOT BE CONSTRUCTED OR RELOCATED
UNTIL SUCH LOCATIONS HAVE BEEN APPROVED BY THE WATER
DEPARTMENT CONSTRUCTION DIVISION IN THE FIELD.
5. ALL DISTANCES SHOWN ARE IN DISTRICT STANDARD
MEASUREMENTS
PIPE TOTALS (THIS SHEET)
310' ± 24" DUCTILE IRON WATER MAIN
285' ± 12" DUCTILE IRON WATER MAIN
5' ± 8" DUCTILE IRON WATER MAIN
20' ± 6" DUCTILE IRON WATER MAIN
APPROVED
CHIEF, DESIGN BRANCH, ENGINEERING DIVISION
DRAWN BY
PROJECT ENGR.
SUPERVISOR DATE
WORK NO.
SHEET NO. OF
CITY OF PHILADELPHIA
WATER DEPARTMENT
WATER MAIN RELAY PROJECT
PURSUANT TO THE REQUIREMENTS OF PENNSYLVANIA ACT 287 OF 1974 (THE UNDERGROUND UTILITY
LINE PROTECTION ACT), AS AMENDED BY PA ACT 121 OF 2008, THE CONTRACTOR
SHALL CONTACT THE PENNSYLVANIA ONE CALL SYSTEM AT 1-800-242-1776, AT LEAST
3 DAYS PRIOR TO EXCAVATION.
HIGHWAY DISTRICT NO. WARD NO.
SURVEY DISTRICT NO.
ONE CALL SERIAL NO.
NOTICE:
WATER PLATE NO.
FROM
SCALES:
PLAN 1" = 20'
AND AS NOTED
W-3
GPIS NO.
g\ ap pd at a\ lo ca l\t em p\
Ac Pu bl ish
_1
\W at er
Sh ee ts .d w g\
-3
Z
AC
H
AR
Y.
YO
U
N G
/6
/2
CS
V
1.
SHEETS
W-20417-DG
ZACHARY YOUNG
ZACHARY YOUNG 12/26/26
12/26/26
COTTAGE STREET
260' WEST OF ROBBINS ST. TO ROBBINS ST. (S.R. 1024)
20240121485
5 55
G2024-00104
M A
TC
H
LI
N
E
SE
E
SH
EE
T
W -2 B
B
COTTAGE STREET
PARKING
NO PARKING
PARKING
NO PARKING
R O
B B
IN
S
ST
S.
R . 1
4)
PA
RK
IN
G
NO PARKING
PA
RK
IN
G
NO PARKING
PROP. 12" CAP(SEE SPEC)
PROP. 24" WATER MAIN
PROP. 24"X12" TEE Water 60" Steel, 4'-0" Cov.
Sewer 21" RCP, 10'-0" Cov.
Approx. Surface
TRANSMISSION MAIN
CROSSING DETAIL
SCALE 18" = 1'-0"
2' -0
PROP. 24" CAP(SEE SPEC)
Water 24", 2'-6" Cov.
THE CONTRACTOR SHALL MAINTAIN A MINIMUM 18-INCH
VERTICAL CLEARANCE WHEN CROSSING UNDER ACTIVE
WATER TRANSMISSION MAINS (16" MAINS AND LARGER).
PROP. 45° BEND
BILL OF MATERIALS
1 STD. FIRE HYDRANT W/CCL
5 STD. 7" VALVE BOX(ES)
2 24" VALVE(S)
1 12" VALVE(S)
2 6" VALVE(S)
1 12"X6" HYDRANT ANCHOR TEE(S)
1 24"X12" TEE(S)
2 12"X12" TEE(S)
1 24"X6" TEE(S)
6 24" 1/8 BENDS (4 VERTICAL)
6 12" 1/8 BENDS(3 VERTICAL)
1 12"X8" REDUCER(S)
3 12" SLEEVE(S)
1 8" SLEEVE(S)
3 24" CAP(S)
1 12" CAP(S)
1 24" MECHANICAL COUPLING(S)
1 6" BLOW-OFF W/CHAMBER
(SEE SPEC)
(TO BE ABAND. )
Water Valve (SEE SPEC)
(SEE SPEC)
PROP. 6" BLOW-OFF W/CHAMBER(SEE SPEC)
PROP. 24"X6" TEE
PROP. 24" BUTTERFLY VALVE
332433
David.Weld Dtw w date Stamp zachary.young Text Box
FINAL DESIGN ONE CALL NO.
zachary.young Line zachary.young
20263060714, 20263060715
6"BB B B B B
E
E
.0
4 .0
.0229
.02277
.0229
.02277
.0
.0
.0
.0
.0077
.0077
D.E.
D.E.
W
W
W V W
G
G W
WV
G G
TS
V ?
W V
V
W
W V
W V
GW
TS
G
W V 12" G V
W
V
W
G G V V
W W G
G W
V
W
V
G WW
W V
G
V
6"W
V
St y.
B ric k
Ro w
H ou se s
St y.
B ric k
Ro w
H ou se s
2 Sty. Brick Row
Houses
2 Sty. Brick Row
Houses 2 St y.
B ric k
Ro w
H ou se s
2 Sty. Brick Row Houses
2 Sty. Brick Row
Houses
#2
#3
4 2
17'-0"
6'-0" 4'-6"
12'-6" 6'-6" 3'-6"
5'-0"
2' -0
'-0
12'-6"
6'-6" 3'-6"
10'-0"
4'-0"
4'-6"
17'-0" 6'-0"
'-0
4' -0
1' -6
6' -0
6' -0
4'
-0
4' -0
Gas 6" , 2'-10" Cov.
Sewer 4'-6" x 3'-0" Br., 9'-8"± Cov.
Water 6", 4'-0" Cov.
10'-0"
(TO BE ABAND.)Water 48", 2'-9" Cov.
Water 30", 2'-6" Cov.
Verizon 18"x 10", 2'-6" Cov.
Verizon 5"x 9, Unk. Cov.
Sewer 2'-6" x 1'-8" Br., 10'-3"± Cov.
Water 6", 3'-7" Cov.
Sewer 8" Dia. TCP, 12'-8"± Cov.
Verizon 18" x 10", 2'-6" Cov.
Water 30", 2'-6" Cov.
Gas 6" , 2'-11" Cov.
Verizon 4", Unk. Cov.
Sewer 18" Dia. RCP, 8'-8"± Cov.
Verizon 4", Unk. Cov.
Water 8", 4'-0" Cov. Water 48", 2'-9" Cov.
Gas 12" H.P. , 3'-0" Cov.
Sewer 4'-6" x 3'-0" Br., 9'-7"± Cov.
Gas 6", 3'-0" Cov.
PROP. 8" D.I. WATER MAIN, 4'-0" COVER
Private Sewer 8" Dia. VCP, Unk. Cov.
Sewer 12" Vent
10'-0"
Gas 6" , 3'-0" Cov.
Water 8", 4'-0" Cov.
7' -9
7' -9
7' -9
Water 6", 4'-0" Cov.
(TO BE ABAND.)
Gas 6" , 3'-0" Cov.
Sewer 18" Dia. RCP 8'-9"± Cov.
Water 8", 4'-0" Cov.
(TO BE ABAND.)
1'-6"
Sewer 12" Vent
6' -0
Gas 12" H.P. , 3'-0" Cov.
PROP. 8" D.I. WATER MAIN, 4'-0" COVER
8' -3
8'-0"
PROP. 30" D.I. WATER MAIN
10'-0"
10'-0"
PROP. 8" D.I. WATER MAIN
(SEE CROSSING DETAIL THIS SHEET)
(SEE SPEC)
SECTION E - E
2' -0
1' -6
REMOVE FRAME & COVER - SEE SPEC'S.
REMOVE FIRE HYDRANT - SEE SPEC'S.
REMOVE PIPE AND/OR FITTING & RECONNECT.
4 ROTATE FITTINGS AS REQUIRED.
5 REMOVE & RETURN VALVE - SEE SPEC'S.
NOTES:
1. EXISTING WATER MAINS SHALL BE CUT & PLUGGED AS
APPROVED BY THE CITY ENGINEER.
2. THE CONTRACTOR SHALL MAINTAIN A MINIMUM 6-INCH
CLEARANCE BETWEEN ALL UNDERGROUND STRUCTURES AND
THE NEW WATER MAINS.
3. BILLS OF MATERIAL AND PIPE TOTALS ARE FOR THE
CONVENIENCE OF THE CONTRACTOR ONLY AND PAYMENT WILL
BE MADE ONLY FOR THE ACTUAL AMOUNT OF PIPE AND
APPURTENANCES INSTALLED.
4. FIRE HYDRANTS SHALL NOT BE CONSTRUCTED OR RELOCATED
UNTIL SUCH LOCATIONS HAVE BEEN APPROVED BY THE WATER
DEPARTMENT CONSTRUCTION DIVISION IN THE FIELD.
5. ALL DISTANCES SHOWN ARE IN DISTRICT STANDARD
MEASUREMENTS
PIPE TOTALS (THIS SHEET)
20' ± 30" DUCTILE IRON WATER MAIN
580' ± 8" DUCTILE IRON WATER MAIN
35' ± 6" DUCTILE IRON WATER MAIN
APPROVED
CHIEF, DESIGN BRANCH, ENGINEERING DIVISION
DRAWN BY
PROJECT ENGR.
SUPERVISOR DATE
WORK NO.
SHEET NO. OF
CITY OF PHILADELPHIA
WATER DEPARTMENT
WATER MAIN RELAY PROJECT
PURSUANT TO THE REQUIREMENTS OF PENNSYLVANIA ACT 287 OF 1974 (THE UNDERGROUND UTILITY
LINE PROTECTION ACT), AS AMENDED BY PA ACT 121 OF 2008, THE CONTRACTOR
SHALL CONTACT THE PENNSYLVANIA ONE CALL SYSTEM AT 1-800-242-1776, AT LEAST
3 DAYS PRIOR TO EXCAVATION.
HIGHWAY DISTRICT NO. WARD NO.
SURVEY DISTRICT NO.
ONE CALL SERIAL NO.
NOTICE:
WATER PLATE NO.
FROM
SCALES:
PLAN 1" = 20'
AND AS NOTED
W-4
GPIS NO.
g\ ap pd at a\ lo ca l\t em p\
Ac Pu bl ish
_1
\W at er
Sh ee ts .d w g\
-4
Z
AC
H
AR
Y.
YO
U
N G
/6
/2
CS
V
1.
SHEETS
W-20417-DG
ZACHARY YOUNG
ZACHARY YOUNG 12/26/26
12/26/26
GILLESPIE STREET
DEVEREAUX AVENUE TO MCKINLEY STREET
20240121477
5 55
G2024-00104
MATCHLINE SEE SHEET W-2
CC
D
EV
ER
EA
U X
A
VE
PA
RK
IN
G
NO PARKING
PA
RK
IN
G
NO PARKING
M C
K
IN
LE
Y
ST
PARKING
N O
P
AR
KI
N
G
PA
RK
IN
G
NO PARKING
GILLESPIE STREET
PARKING
NO PARKING PARKING
NO PARKING
M A
TC
H
LI
N
E
SE
E
SH
EE
T
W -5
E E
THE CONTRACTOR SHALL MAINTAIN A MINIMUM 18-INCH
VERTICAL CLEARANCE WHEN CROSSING UNDER ACTIVE
WATER TRANSMISSION MAINS (16" MAINS AND LARGER).
BILL OF MATERIALS
2 STD. FIRE HYDRANT W/CCL
7 STD. 7" VALVE BOX(ES)
5 8" VALVE(S)
2 6" VALVE(S)
1 8"X8" CROSS(ES)
1 8"X6" HYDRANT ANCHOR TEE(S)
1 8"X8" TEE(S)
1 8"X6" TEE(S)
16 8" 1/8 BENDS (12 VERTICAL)
2 6" 1/8 BENDS (0 VERTICAL)
1 8"X6" REDUCER(S)
2 8" SLEEVE(S)
1 6" SLEEVE(S)
2 30" MECHANICAL COUPLING(S)
TRANSMISSION MAIN
CROSSING DETAIL
SCALE 18" = 1'-0"
Water 6" Verizon 18"x10" Water 48"
Gas 12"
Gas 6"
Sewer 4'-6"x3'-6" Br.
PROP. 30" WATER
MAIN
PROP. 8" WATER
MAIN
PROP. 8"X8" CROSS
Approx. Surface
333333
David.Weld Dtw w date Stamp zachary.young Text Box
FINAL DESIGN ONE CALL NO.
zachary.young Line zachary.young
20263060792, 20263060793
6"6"4"12"4" 6"6"B
F
F
.0229
.02277
.0229
.02277 .01707
.01628
.0
.0
.0
.0
W
V
W
V
G V V W
V V G G
W
V
W
V V W V
W V V W
W V V W G
V V W W
V
W WGG
V
W
W
V
G
V
W G
V
GW G
B B
W V V V V
W
V
W
V V W
V
X
X
WVV V
W W
V V
W ?GG
C.
D
/W De p.
C ur b
C.
D
/W De p.
C ur b
W
WV V
W
V
W V
2 Sty. Brick Row Houses
2 Sty. Brick Row Houses
2 Sty. Brick Row Houses
2 Sty. Brick Row Houses
4' -0
6' -0
6' -0
4' -0
6'
-0
6' -0
4'
-0
7' -6
4'-0"
5'-0"
13'-0" 3'-6"
8'-6"
8' -0
5' -0
8' -0
'-0
6'-0" 4'-3"
17'-0" 8'-0"
3'-0"
3'-6" 13'-0"
Sewer 21" Dia. RCP, 9'-10"± Cov.
Water 12", 4'-0" Cov.
(TO BE ABAND.)
7' -9
7' -9
Water 6", 4'-0" Cov.
(TO BE ABAND.)
Gas 6" , 3'-0" Cov.
Sewer 18" Dia. RCP 8'-9"± Cov.
Gas 6" , 2'-6" Cov.
Water 8", 4'-0" Cov.
(TO BE ABAND.)
PROP. 8" D.I. WATER MAIN, 4'-0" COVER
Gas 6" , 3'-0" Cov.
Water 8", 4'-0" Cov.
(TO BE ABAND.)
Water 8", 4'-0" Cov.
5'-9"
Water 8", 4'-0" Cov.
Gas 6" , 3'-0" Cov.
Sewer 12'-0" x 8'-0" RCP, 11'-2"± Cov.
Water 60", 4'-0" Cov.
Water 24", 2'-4" Cov.
Gas 6" , 2'-7" Cov.
Gas 6" , 3'-0" Cov.
Sewer 12'-0" x 8'-0" RCP, 10'-5"± Cov.
Water 8", 4'-0" Cov.
Gas 6" , 2'-11" Cov.
Gas 6" , 2'-10" Cov.
Water 60" Steel, 3'-6" Cov.
Water 24", 2'-4" Cov.
Sewer 36" Dia. RCP, 11'-2"± Cov.Water 8", 4'-0" Cov.
Sewer 3'-6" x 2'-4" Br., 10'-4"± Cov.
Sewer 2'-3" x 1'-6" Br., 10'-4"± Cov.
Water 6", 4'-0" Cov.
(TO BE ABAND.)
Gas 6" , 2'-7" Cov.
6' -6
4' -0
Water Valve Found In Field
Water Valve Found In Field
PROPOSED ZAYO FIBEROPTIC 2",
AT GRADE
13'-0"
SECTION F - F
REMOVE FRAME & COVER - SEE SPEC'S.
REMOVE FIRE HYDRANT - SEE SPEC'S.
REMOVE PIPE AND/OR FITTING & RECONNECT.
4 ROTATE FITTINGS AS REQUIRED.
5 REMOVE & RETURN VALVE - SEE SPEC'S.
NOTES:
1. EXISTING WATER MAINS SHALL BE CUT & PLUGGED AS
APPROVED BY THE CITY ENGINEER.
2. THE CONTRACTOR SHALL MAINTAIN A MINIMUM 6-INCH
CLEARANCE BETWEEN ALL UNDERGROUND STRUCTURES AND
THE NEW WATER MAINS.
3. BILLS OF MATERIAL AND PIPE TOTALS ARE FOR THE
CONVENIENCE OF THE CONTRACTOR ONLY AND PAYMENT WILL
BE MADE ONLY FOR THE ACTUAL AMOUNT OF PIPE AND
APPURTENANCES INSTALLED.
4. FIRE HYDRANTS SHALL NOT BE CONSTRUCTED OR RELOCATED
UNTIL SUCH LOCATIONS HAVE BEEN APPROVED BY THE WATER
DEPARTMENT CONSTRUCTION DIVISION IN THE FIELD.
5. ALL DISTANCES SHOWN ARE IN DISTRICT STANDARD
MEASUREMENTS
BILL OF MATERIALS
4 8" 1/8 BENDS (4 VERTICAL)
1 8" SLEEVE(S)
PIPE TOTALS (THIS SHEET)
295' ± 8" DUCTILE IRON WATER MAIN
APPROVED
CHIEF, DESIGN BRANCH, ENGINEERING DIVISION
DRAWN BY
PROJECT ENGR.
SUPERVISOR DATE
WORK NO.
SHEET NO. OF
CITY OF PHILADELPHIA
WATER DEPARTMENT
WATER MAIN RELAY PROJECT
PURSUANT TO THE REQUIREMENTS OF PENNSYLVANIA ACT 287 OF 1974 (THE UNDERGROUND UTILITY
LINE PROTECTION ACT), AS AMENDED BY PA ACT 121 OF 2008, THE CONTRACTOR
SHALL CONTACT THE PENNSYLVANIA ONE CALL SYSTEM AT 1-800-242-1776, AT LEAST
3 DAYS PRIOR TO EXCAVATION.
HIGHWAY DISTRICT NO. WARD NO.
SURVEY DISTRICT NO.
ONE CALL SERIAL NO.
NOTICE:
WATER PLATE NO.
FROM
SCALES:
PLAN 1" = 20'
AND AS NOTED
W-5
GPIS NO.
g\ ap pd at a\ lo ca l\t em p\
Ac Pu bl ish
_1
\W at er
Sh ee ts .d w g\
-5
Z
AC
H
AR
Y.
YO
U
N G
/6
/2
CS
V
1.
SHEETS
W-20417-DG
ZACHARY YOUNG
ZACHARY YOUNG 12/26/26
12/26/26
GILLESPIE STREET
MCKINLEY STREET TO ROBBINS STREET(S.R 1024)
20240121477
5 55
G2024-00104
M A
TC
H
LI
N
E
SE
E
SH
EE
T
W -4
E E
GILLESPIE STREET
PARKING
NO PARKINGPARKING
NO PARKING
R O
B B
IN
S
ST
S.
R . 1
4)
PA
RK
IN
G
NO PARKING
PA
RK
IN
G
NO PARKING
333333
David.Weld Dtw w date Stamp zachary.young Text Box
FINAL DESIGN ONE CALL NO.
zachary.young Line zachary.young
20263060792, 20263060793
Row
Houses
2 Sty. Brick Row Houses
36"
36" 36" 24"
.0
.0
.0269
.0269.0216
.02176
.0
.0
.0216
.02176
.0
.0
.0216
.02276
.0
.0
6 .0
34 .0
34G
G
V W
V
W
V
TS
V
V
W
G
G
W
TS
V
V
G G
V
G
W V
? V V V
GG
V
VG
G
W
V V
G W
W
V
G
W V W W W W V W W W
V V V V
TS
VW V V W V W V W V W V
GGG GG GG
G
C/R
X X
X
TS
VW
TS
W
V
G G
G G
V
V
W
G
G
2 Sty. Brick Row
Houses 2 Sty. Brick Row Houses
2 Sty. Brick Row Houses
2 Sty. Brick Row
Houses
St y.
B ric k
Ro w
H ou se s
St y.
B ric k
Ro w
H ou se s
St y.
B ric k
Ro w
H ou se s
St y.
B ric k
Ro w
H ou se s
PROPOSED GSI TRENCH
(SEE SHEET G-1)
#2
#3
#25
1 2
6'-0"
9'-11"
6'-0" 1'-6"
6'-0"
1'-6" 13'-0"
10'-0" 1'-0"
6'-0"
5'-10"
6'-0"
8'-0"
6'-0"
4'-4" 17'-0"
16'-3"
3'-9" 5'-10"
8'-0" 2'-0"
8'-3"
13'-5"
5'-11" 8'-0"8'-0"
3'-0"
Water 8", 4'-0" Cov.
Gas 6", 3'-0" Cov.
Private Sewer 8" Dia. VCP, Unk. Cov.
Gas 6", 3'-0" Cov.
Sewer 21" Dia. RCP, 9'-7"± Cov.
Sewer 18" Dia. RCP, 9'-10"± Cov.
Water 8", 4'-0" Cov.
(TO BE ABAND.)
Verizon 4", Unk. Cov.
11'-0"
11'-0"
Sewer 18" Dia. RCP, 10'-10"± Cov.
Sewer 12" Vent Gas 6", 3'-0" Cov.
Private Sewer 8" Dia. RCP, 10'-7"± Cov.
Water 8", 4'-0" Cov.
PROP. 8" D.I. WATER MAIN,
4'-0" COVER
Water 8", 4'-0" Cov.
Sewer 12" Vent
Sewer 21" Dia. RCP, 12'-8"± Cov.
Gas 6" , 3'-0" Cov.
Sewer 21" Dia. RCP, 11'-2"± Cov.
1'-6" 1'-6"
13'-0"
8'-0"
8' -0
13'-0" Water 8", 4'-0" Cov.
Gas 6" , 2'-10" Cov.
Gas 6" , 2'-8" Cov.
Water 8", 3'-6" Cov.
Gas 4" , 2'-8" Cov.
Gas 4" , 2'-2" Cov.
Water 24", 2'-4" Cov.
Water 60", 4'-6" Cov.
Sewer 8'-0" x 12'-0" RCP, 10'-9"± Cov.
Sewer 2'-3" x 1'-6" Br., 11'-9"± Cov.
Gas 6" , 2'-11" Cov.
Water 24", 2'-4" Cov.
Water 60", 4'-6" Cov.
Sewer 8'-0" x 12'-0" RCP, 10'-9"± Cov.
Water 8", 4'-0" Cov.
Gas 6" , 3'-0" Cov.
1'-6" 1'-6"
13'-0"
(TO BE ABAND.)
8'-0"
Sewer 2'-3" x 1'-6" Br., 11'-4"± Cov.
Private Sewer 4' Dia Br., Unk. Cov.
Gas 6", 3'-0" Cov.
8'-8"
1' -6
PROPOSED GSI TRENCH
(SEE SHEET G-1)
PROPOSED GSI TRENCH
(SEE SHEET G-3)
PROPOSED GSI TRENCH
(SEE SHEET G-4)
7'-0"
7'-3"
'-6
'-6
PROPOSED ZAYO FIBEROPTIC 2",
AT GRADE
13'-0"
5'-0"
SECTION G - G
REMOVE FRAME & COVER - SEE SPEC'S.
REMOVE FIRE HYDRANT - SEE SPEC'S.
REMOVE PIPE AND/OR FITTING & RECONNECT.
4 ROTATE FITTINGS AS REQUIRED.
5 REMOVE & RETURN VALVE - SEE SPEC'S.
NOTES:
1. EXISTING WATER MAINS SHALL BE CUT & PLUGGED AS
APPROVED BY THE CITY ENGINEER.
2. THE CONTRACTOR SHALL MAINTAIN A MINIMUM 6-INCH
CLEARANCE BETWEEN ALL UNDERGROUND STRUCTURES AND
THE NEW WATER MAINS.
3. BILLS OF MATERIAL AND PIPE TOTALS ARE FOR THE
CONVENIENCE OF THE CONTRACTOR ONLY AND PAYMENT WILL
BE MADE ONLY FOR THE ACTUAL AMOUNT OF PIPE AND
APPURTENANCES INSTALLED.
4. FIRE HYDRANTS SHALL NOT BE CONSTRUCTED OR RELOCATED
UNTIL SUCH LOCATIONS HAVE BEEN APPROVED BY THE WATER
DEPARTMENT CONSTRUCTION DIVISION IN THE FIELD.
5. ALL DISTANCES SHOWN ARE IN DISTRICT STANDARD
MEASUREMENTS
BILL OF MATERIALS
2 STD. FIRE HYDRANT W/CCL
6 STD. 7" VALVE BOX(ES)
4 8" VALVE(S)
2 6" VALVE(S)
2 8"X6" HYDRANT ANCHOR TEE(S)
2 8"X8" TEE(S)
24 8" 1/8 BENDS (16 VERTICAL)
2 6" 1/8 BENDS (2 VERTICAL)
3 8" SLEEVE(S)
PIPE TOTALS (THIS SHEET)
540' ± 8" DUCTILE IRON WATER MAIN
25' ± 6" DUCTILE IRON WATER MAIN
APPROVED
CHIEF, DESIGN BRANCH, ENGINEERING DIVISION
DRAWN BY
PROJECT ENGR.
SUPERVISOR DATE
WORK NO.
SHEET NO. OF
CITY OF PHILADELPHIA
WATER DEPARTMENT
WATER MAIN RELAY PROJECT
PURSUANT TO THE REQUIREMENTS OF PENNSYLVANIA ACT 287 OF 1974 (THE UNDERGROUND UTILITY
LINE PROTECTION ACT), AS AMENDED BY PA ACT 121 OF 2008, THE CONTRACTOR
SHALL CONTACT THE PENNSYLVANIA ONE CALL SYSTEM AT 1-800-242-1776, AT LEAST
3 DAYS PRIOR TO EXCAVATION.
HIGHWAY DISTRICT NO. WARD NO.
SURVEY DISTRICT NO.
ONE CALL SERIAL NO.
NOTICE:
WATER PLATE NO.
FROM
SCALES:
PLAN 1" = 20'
AND AS NOTED
W-6
GPIS NO.
g\ ap pd at a\ lo ca l\t em p\
Ac Pu bl ish
_1
\W at er
Sh ee ts .d w g\
-6
Z
AC
H
AR
Y.
YO
U
N G
/6
/2
CS
V
1.
SHEETS
W-20417-DG
ZACHARY YOUNG
ZACHARY YOUNG 12/26/26
12/26/26
JACKSON STREET
MCKINLEY STREET TO ROBBINS STREET(S.R. 1024)
20240121553,2024012155
5 41, 55
G2024-00104
MATCHLINE SEE SHEET W-7
FF
JACKSON STREET
PARKING
NO PARKING
PARKING
NO PARKING
H A
LE
S
T.
PA
RK
IN
G
NO PARKING
PA
RK
IN
G
NO PARKING
R O
B B
IN
S
ST
S.
R . 1
4)
PA
RK
IN
G
NO PARKING
PA
RK
IN
G
NO PARKING
M C
K
IN
LE
Y
ST
PARKING
N O
P
AR
KI
N
G
PA
RK
IN
G
NO PARKING
Gas 4", 3'-0" Cov.
Gas 4", 3'-0" Cov.
Water 8", 4'-0" Cov.
Sewer 18" Dia. RCP, 8'-3" ± Cov.
Gas 4", 3'-0" Cov.
(TO BE ABAND.)
PROP. 8" D.I. WATER
MAIN, 4'-0" COVER.
333333
David.Weld Dtw w date Stamp zachary.young Text Box
FINAL DESIGN ONE CALL NO.
zachary.young Line zachary.young
20263060820, 20263060821
.008213
.008213
.008213
.008213
H
H
G G G G
G G W W
G G V G
G G
W W V V
GG
V W W V G G
W V V
G G
? V V ? V V G
G V V W
G G
W V
W V
2 Sty. Brick Row Houses
2 Sty. Brick Row Houses
'-0
1' -6
1'
-6
'-0
Sewer 18" Dia. RCP, 8'-3"± Cov.
Gas 4", 3'-0" Cov.
Water 8", 4'-0" Cov.
(TO BE ABAND.)
Gas 4", 3'-0" Cov. PROP. 8" D.I. WATER MAIN, 4'-0" COVER
'-0
1' -6
8'
-0
1' -6
'-0
Sewer 18" Dia. RCP, 9'-7"± Cov.
SECTION H - H
REMOVE FRAME & COVER - SEE SPEC'S.
REMOVE FIRE HYDRANT - SEE SPEC'S.
REMOVE PIPE AND/OR FITTING & RECONNECT.
4 ROTATE FITTINGS AS REQUIRED.
5 REMOVE & RETURN VALVE - SEE SPEC'S.
NOTES:
1. EXISTING WATER MAINS SHALL BE CUT & PLUGGED AS
APPROVED BY THE CITY ENGINEER.
2. THE CONTRACTOR SHALL MAINTAIN A MINIMUM 6-INCH
CLEARANCE BETWEEN ALL UNDERGROUND STRUCTURES AND
THE NEW WATER MAINS.
3. BILLS OF MATERIAL AND PIPE TOTALS ARE FOR THE
CONVENIENCE OF THE CONTRACTOR ONLY AND PAYMENT WILL
BE MADE ONLY FOR THE ACTUAL AMOUNT OF PIPE AND
APPURTENANCES INSTALLED.
4. FIRE HYDRANTS SHALL NOT BE CONSTRUCTED OR RELOCATED
UNTIL SUCH LOCATIONS HAVE BEEN APPROVED BY THE WATER
DEPARTMENT CONSTRUCTION DIVISION IN THE FIELD.
5. ALL DISTANCES SHOWN ARE IN DISTRICT STANDARD
MEASUREMENTS
PIPE TOTALS (THIS SHEET)
305' ± 8" DUCTILE IRON WATER MAIN
APPROVED
CHIEF, DESIGN BRANCH, ENGINEERING DIVISION
DRAWN BY
PROJECT ENGR.
SUPERVISOR DATE
WORK NO.
SHEET NO. OF
CITY OF PHILADELPHIA
WATER DEPARTMENT
WATER MAIN RELAY PROJECT
PURSUANT TO THE REQUIREMENTS OF PENNSYLVANIA ACT 287 OF 1974 (THE UNDERGROUND UTILITY
LINE PROTECTION ACT), AS AMENDED BY PA ACT 121 OF 2008, THE CONTRACTOR
SHALL CONTACT THE PENNSYLVANIA ONE CALL SYSTEM AT 1-800-242-1776, AT LEAST
3 DAYS PRIOR TO EXCAVATION.
HIGHWAY DISTRICT NO. WARD NO.
SURVEY DISTRICT NO.
ONE CALL SERIAL NO.
NOTICE:
WATER PLATE NO.
FROM
SCALES:
PLAN 1" = 20'
AND AS NOTED
W-7
GPIS NO.
g\ ap pd at a\ lo ca l\t em p\
Ac Pu bl ish
_1
\W at er
Sh ee ts .d w g\
-7
Z
AC
H
AR
Y.
YO
U
N G
/6
/2
CS
V
1.
SHEETS
W-20417-DG
ZACHARY YOUNG
ZACHARY YOUNG 12/26/26
12/26/26
HALE STREET
JACKSON STREET TO DITMAN STREET
20240121560,20240121566
5 41
G2024-00104
M A
TC
H
LI
N
E
SE
E
SH
EE
T
W -8
G G
M A
TC
H
LI
N
E
SE
E
SH
EE
T
W -6
F F
HALE STREET
PARKING
NO PARKING
PARKING
NO PARKING
333333
David.Weld Dtw w date Stamp zachary.young Text Box
FINAL DESIGN ONE CALL NO.
zachary.young Line zachary.young
20263060807, 20263060808
8"
J
J
.0189
.0189
.0189
.0189
.0
.0
.0
.0
.0249
.0249
.008213
.008213
D.
E.
GG
V
G
V W
G G W
V W
V
V
V
W G G
V
X
XXXXXX
C. D/W Dep. Curb
G G
W V V V V
W W
G G
V ? V
VW
VW
X X
XXXXXX
GV
GW
G W
G
G
V
W
B
B
B
B
B
B
G
V W W GV V
G W
V
W W V
BB
B B
TS
X X
X X
X
G
VW
G G
2 Sty. Brick Row
Houses2 St y.
B ric k
Ro w
H ou se s
St y.
B ric k
Ro w
H ou se s
2 Sty. Brick Row Houses
2 Sty. Brick Row Houses
2 Sty. Brick Row Houses
1'-6"
Alleyway (Conc.)
11'-0"
1'-6"
1'-6"
8'-0"
1'-6"
13'-0"
8'-0"
13'-0"
1'-6" 11'-0"
10'-0"
3'-6"
13'-0" 3'-6"
10'-0" 13'-0"
3'-6"
8'-9"
8'-0"
4'-11"
8'-9"
8'-0"
4'-11"
13'-0"
3'-6"
6'-8"
Sewer 2'-6" x 1'-8" Br., 10'-10"± Cov.
Water 8", 3'-6" Cov.
Gas H.P. 20" , 2'-8" Cov.
Gas 4", 2'-6" Cov.
4'-0"
2'-0"
14'-4" 5'-0"
Sewer 10'-0" Dia.
RCP, 11'-5"± Cov.
Water 8", 3'-6" Cov.
Water 60" Steel, 4'-6" Cov.
Water 24", 2'-4" Cov.
Gas 6", 2'-7" Cov.
Gas 6", 2'-0" Cov.Gas 6", 2'-5" Cov.
Sewer 21"Dia. RCP, 11'-6"± Cov.
Verizon 5" x 9", Unk. Cov.
Water 8", 4'-0" Cov.
(TO BE ABAND.)
Water 24", 2'-4" Cov.
Water 60" Steel, 4'-6" Cov.
2'-0"
14'-4"
5'-5" 6'-9"
Sewer 18"Dia. RCP, 10'-9"± Cov.
PROP. 12" D.I. WATER MAIN, 4'-0" COVER
Sew er 18" Dia. RCP, 9'-7"± Cov.
8'-0"
8'-0"
Sewer 21"Dia. RCP, 11'-6"± Cov.
Sewer 2'-3" x 1'-6" Br., 11'-1"± Cov.
Sewer 10' Dia. Br., 12'-2"± Cov.
Sewer 2'-6" x 1'-8" Br., 10'-10"± Cov.
Gas 6", 3'-0" Cov.
Gas H.P. 20" , 10'-5" Cov.
Gas H.P. 20" , 5'-0" Cov.
Water 8", 4'-0" Cov.
Gas 6", 2'-0" Cov.
PROP. 24" D.I. WATER MAIN
(SEE SPEC.)
PROP. GAS 4" (PROPOSED BY PGW
4X5477)
(TO BE ABAND. BY PGW)
11'-0"
13'-0"
11'-0"
PROP. 8" D.I.
WATER MAIN
6'-6"
PROPOSED ZAYO
FIBEROPTIC 2", AT GRADE
(SEE SPEC)
PROPOSED ZAYO FIBEROPTIC 2",
AT GRADE
(SEE SPEC)
5'-0"
SECTION J - J
PROP. ZAYO FIBEROPTIC,
AT GRADE
6'-6"
3' -6
5' -2
6'-2"
Gas H.P. 20", 3'-0" Cov.
Verizon 4", Unk. Cov.
Verizon 4", Unk. Cov.
Gas H.P. 20", 3'-0" Cov.
Verizon 4", Unk. Cov.
Verizon 5" x 9", Unk. Cov.
REMOVE FRAME & COVER - SEE SPEC'S.
REMOVE FIRE HYDRANT - SEE SPEC'S.
REMOVE PIPE AND/OR FITTING & RECONNECT.
4 ROTATE FITTINGS AS REQUIRED.
5 REMOVE & RETURN VALVE - SEE SPEC'S.
NOTES:
1. EXISTING WATER MAINS SHALL BE CUT & PLUGGED AS
APPROVED BY THE CITY ENGINEER.
2. THE CONTRACTOR SHALL MAINTAIN A MINIMUM 6-INCH
CLEARANCE BETWEEN ALL UNDERGROUND STRUCTURES AND
THE NEW WATER MAINS.
3. BILLS OF MATERIAL AND PIPE TOTALS ARE FOR THE
CONVENIENCE OF THE CONTRACTOR ONLY AND PAYMENT WILL
BE MADE ONLY FOR THE ACTUAL AMOUNT OF PIPE AND
APPURTENANCES INSTALLED.
4. FIRE HYDRANTS SHALL NOT BE CONSTRUCTED OR RELOCATED
UNTIL SUCH LOCATIONS HAVE BEEN APPROVED BY THE WATER
DEPARTMENT CONSTRUCTION DIVISION IN THE FIELD.
5. ALL DISTANCES SHOWN ARE IN DISTRICT STANDARD
MEASUREMENTS
BILL OF MATERIALS
1 STD. FIRE HYDRANT W/CCL
3 STD. 7" VALVE BOX(ES)
2 12" VALVE(S)
1 8" VALVE(S)
1 6" VALVE(S)
1 12"X8" CROSS(ES)
1 8"X6" HYDRANT ANCHOR TEE(S)
1 24"X12" TEE(S)
1 12"X12" TEE(S)
1 12"X8" TEE(S)
23 12" 1/8 BENDS (19 VERTICAL)
8 8" 1/8 BENDS (2 VERTICAL)
1 12"X8" REDUCER(S)
3 8" SLEEVE(S)
2 24" MECHANICAL COUPLING(S)
PIPE TOTALS (THIS SHEET)
25' ± 24" DUCTILE IRON WATER MAIN
400' ± 12" DUCTILE IRON WATER MAIN
125' ± 8" DUCTILE IRON WATER MAIN
15' ± 6" DUCTILE IRON WATER MAIN
APPROVED
CHIEF, DESIGN BRANCH, ENGINEERING DIVISION
DRAWN BY
PROJECT ENGR.
SUPERVISOR DATE
WORK NO.
SHEET NO. OF
CITY OF PHILADELPHIA
WATER DEPARTMENT
WATER MAIN RELAY PROJECT
PURSUANT TO THE REQUIREMENTS OF PENNSYLVANIA ACT 287 OF 1974 (THE UNDERGROUND UTILITY
LINE PROTECTION ACT), AS AMENDED BY PA ACT 121 OF 2008, THE CONTRACTOR
SHALL CONTACT THE PENNSYLVANIA ONE CALL SYSTEM AT 1-800-242-1776, AT LEAST
3 DAYS PRIOR TO EXCAVATION.
HIGHWAY DISTRICT NO. WARD NO.
SURVEY DISTRICT NO.
ONE CALL SERIAL NO.
NOTICE:
WATER PLATE NO.
FROM
SCALES:
PLAN 1" = 20'
AND AS NOTED
W-8
GPIS NO.
g\ ap pd at a\ lo ca l\t em p\
Ac Pu bl ish
_1
\W at er
Sh ee ts .d w g\
-8
Z
AC
H
AR
Y.
YO
U
N G
/6
/2
CS
V
1.
SHEETS
W-20417-DG
ZACHARY YOUNG
ZACHARY YOUNG 12/26/26
12/26/26
DITMAN STREET
MCKINLEY STREET TO ROBBINS STREET(S.R. 1024)
20240121491
5 41
G2024-00104
MATCHLINE SEE SHEET W-7
GG
DITMAN STREET
PARKING
NO PARKING
PARKING
NO PARKING
R O
B B
IN
S
ST
S.
R . 1
4)
PA
RK
IN
G
NO PARKING
PA
RK
IN
G
NO PARKING
H A
LE
S
T.
PA
RK
IN
G
NO PARKING
PA
RK
IN
G
NO PARKING
PROP. 8" D.I. WATER MAIN
Sewer 18" RCP, 10'-9" Cov.
Gas 4", 3'-0" Cov.
Water 8", 4'-0" Cov.
Gas 4", 3'-0" Cov.
PROP. 4" GAS, PGW 4X5477
Ex. 4" Gas
PROP. 12" D.I. WATER
PROP. 24" D.I. WATER
12" D.I. BENDS WITH THRUST
BLOCKS(NOT SHOWN)
12" R.C. DETAIL
SCALE 18" = 1'-0"
THE CONTRACTOR SHALL MAINTAIN A MINIMUM 18-INCH
VERTICAL CLEARANCE WHEN CROSSING UNDER ACTIVE
WATER TRANSMISSION MAINS (16" MAINS AND LARGER).
M A
TC
H
LI
N
E
SE
E
SH
EE
T
W -9
H H
TRANSMISSION MAIN
CROSSING DETAIL
SCALE 18" = 1'-0"
Water 60" Steel
Sewer 10'-0" Dia. Br.
Water 8"Gas 6" PROP. 24" WATER MAIN
PROP. 12"X12" TEE
PROP. 12" WATER MAIN
PROP. 12"X8" CROSS
PROP. 12" D.I. WATER MAIN
(SEE CROSSING DETAIL THIS SHEET)
2' -0
(SEE SPEC)
333333
David.Weld Dtw w date Stamp zachary.young Text Box
FINAL DESIGN ONE CALL NO.
zachary.young Line zachary.young
20263060767, 20263060768, 20263060769
36"
24"
24"
.0
.0
.0
.0
.0126
.013
.01892
.0188
.01892
.0188
.0
.0
.0
.0
.0189
.0189
K
K
D.
E.
D.
E.
D.E.
D.
E.
D.
E.
XXXX
V
G
G
V W
V
W
G
V
W
G
X X
XXXXXXXX
TS
V
TS
TS
TS
G V
G
TS
V
W
G
V
X
XXXXXXX
TS
G
W
V W
V
V
G
V W
2 Sty. Brick Row
Houses2 St y.
B ric k
Ro w
H ou se s
2 Sty. Brick Row
Houses 2 Sty. Brick
Row Houses
St y.
B ric k
Ro w
H ou se s
2 Sty. Brick Row
Houses
St y.
B ric k
Ro w
H ou se s
St y.
B ric k
Ro w
H ou se s
#3
3 4
A.V.
10'-0"
13'-0"
4'-11"
8'-9"
3'-6"
1'-0"
6'-0" 9'-2"
3'-6" 3'-0"
10'-0"
4'-5" 11'-6"
13'-0"
8'-0" 1'-6"
12'-5"17'-0"
4'-6" 2'-6"
10'-0" 6'-8"
13'-4"
3'-6" 8'-1" 3'-6" 5'-9"
5'-5"
6'-0" 1'-0" 4'-6"
10'-0"
17'-0"
12'-6"
1'-6" 8'-0"
4'-3"
1'-0" 9'-8"
5'-0"
Sewer 18"Dia. RCP, 9'-0"± Cov.
Private Sewer 8" Dia.
VCP, 5'-10"± Cov.
Gas 6", 3'-0" Cov.
Water 8", 3'-6" Cov.
Verizon 5"x9", 1'-10" Cov. & 10"x10", 3'-0" Cov.
Gas H.P. 20", 3'-7" Cov.
Private Sewer 8"Dia.
VCP, 12'-10"± Cov.
Water 6", 4'-0" Cov.
(TO BE ABAND.)
Verizon 4", Unk. Cov.
Verizon 5" x 10", 2'-6" Cov.
Sewer 4'-6" x 3'-0" Br. 9'-9"± Cov.
Gas 6", 3'-0" Cov.
Gas 12", 3'-9" Cov.
Water 8", 4'-10" Cov.
Water 48", 2'-9" Cov.
Water 30", 2'-0" Cov.
Verizon 9" x 13", 3'-0" Cov.
Verizon 9" x 9", 5'-11" Cov.
Gas 6", 3'-0" Cov.
Gas 12", 3'-9" Cov.
Sewer 4'-6" x 3'-0" Br. 9'-4"± Cov.
Water 48", 2'-8" Cov.
Water 8", 4'-10" Cov.
Water 30", 2'-0" Cov.
Verizon 9" x 9", 3'-2" Cov.
Gas H.P. 20", 7'-3" Cov.
Water 12", 5'-0" Cov.
Sewer 2'-6" x 1'-8" Br. 10'-11"± Cov.
Gas H.P. 12", 2'-6" Cov.
Gas 6", 3'-5" Cov.
Verizon 5" x 10", 2'-8" Cov.
10'-0"
Water 8", 5'-6" Cov.
Water 6", 3'-6" Cov.
Sewer 18"Dia. RCP, 10'-0"± Cov.
Sewer 18"Dia. RCP, 9'-10"± Cov.
Gas H.P. 20", 3'-2" Cov.
4'-0"
PROP. 8" D.I. WATER MAIN
PROP. 8" D.I. WATER MAIN
PROP. 30" WATER MAIN (SEE SPEC)
7'-0"
PROPOSED 12" CAP(SEE SPEC.)
PROP. 12" D.I. ROUND
CONNECTION
7'-8"
12'-4"
District Boundary Control Valve (To Remain Closed)
PROP. 12" D.I. WATER MAIN
PROP. 2" MANUAL AIR VALVE W/CHAMBER
1' -6
2' -0
SECTION K - K
Gas H.P. 20", 3'-0" Cov.
Verizon 5"x9", 3'-3" Cov.
10"x10, 3'-0" Cov.
Gas 6", 3'-0" Cov.
Water 6", 3'-6" Cov.
Sewer 18"Dia. RCP, 10'-7"± Cov.
Sewer 12" Vent
REMOVE FRAME & COVER - SEE SPEC'S.
REMOVE FIRE HYDRANT - SEE SPEC'S.
REMOVE PIPE AND/OR FITTING & RECONNECT.
4 ROTATE FITTINGS AS REQUIRED.
5 REMOVE & RETURN VALVE - SEE SPEC'S.
NOTES:
1. EXISTING WATER MAINS SHALL BE CUT & PLUGGED AS
APPROVED BY THE CITY ENGINEER.
2. THE CONTRACTOR SHALL MAINTAIN A MINIMUM 6-INCH
CLEARANCE BETWEEN ALL UNDERGROUND STRUCTURES AND
THE NEW WATER MAINS.
3. BILLS OF MATERIAL AND PIPE TOTALS ARE FOR THE
CONVENIENCE OF THE CONTRACTOR ONLY AND PAYMENT WILL
BE MADE ONLY FOR THE ACTUAL AMOUNT OF PIPE AND
APPURTENANCES INSTALLED.
4. FIRE HYDRANTS SHALL NOT BE CONSTRUCTED OR RELOCATED
UNTIL SUCH LOCATIONS HAVE BEEN APPROVED BY THE WATER
DEPARTMENT CONSTRUCTION DIVISION IN THE FIELD.
5. ALL DISTANCES SHOWN ARE IN DISTRICT STANDARD
MEASUREMENTS
BILL OF MATERIALS
2 STD. FIRE HYDRANT W/CCL
10 STD. 7" VALVE BOX(ES)
5 12" VALVE(S)
3 8" VALVE(S)
2 6" VALVE(S)
2 12"X8" CROSS(ES)
1 12"X6" HYDRANT ANCHOR TEE(S)
1 8"X6" HYDRANT ANCHOR TEE(S)
1 30"X12" TEE(S)
2 12"X12" TEE(S)
16 12" 1/8 BENDS (13 VERTICAL)
12 8" 1/8 BENDS (4 VERTICAL)
5 6" 1/8 BENDS (2 VERTICAL)
1 12"X6" REDUCER(S)
1 8"X6" REDUCER(S)
1 12" SLEEVE(S)
3 8" SLEEVE(S)
2 6" SLEEVE(S)
2 30" MECHANICAL COUPLING(S)
1 12" CAP(S)
1 12" 2" MANUAL AIR VALVE
PIPE TOTALS (THIS SHEET)
20' ± 30" DUCTILE IRON WATER MAIN
410' ± 12" DUCTILE IRON WATER MAIN
140' ± 8" DUCTILE IRON WATER MAIN
35' ± 6" DUCTILE IRON WATER MAIN
APPROVED
CHIEF, DESIGN BRANCH, ENGINEERING DIVISION
DRAWN BY
PROJECT ENGR.
SUPERVISOR DATE
WORK NO.
SHEET NO. OF
CITY OF PHILADELPHIA
WATER DEPARTMENT
WATER MAIN RELAY PROJECT
PURSUANT TO THE REQUIREMENTS OF PENNSYLVANIA ACT 287 OF 1974 (THE UNDERGROUND UTILITY
LINE PROTECTION ACT), AS AMENDED BY PA ACT 121 OF 2008, THE CONTRACTOR
SHALL CONTACT THE PENNSYLVANIA ONE CALL SYSTEM AT 1-800-242-1776, AT LEAST
3 DAYS PRIOR TO EXCAVATION.
HIGHWAY DISTRICT NO. WARD NO.
SURVEY DISTRICT NO.
ONE CALL SERIAL NO.
NOTICE:
WATER PLATE NO.
FROM
SCALES:
PLAN 1" = 20'
AND AS NOTED
W-9
GPIS NO.
g\ ap pd at a\ lo ca l\t em p\
Ac Pu bl ish
_1
\W at er
Sh ee ts .d w g\
-9
Z
AC
H
AR
Y.
YO
U
N G
/6
/2
CS
V
1.
SHEETS
W-20417-DG
ZACHARY YOUNG
ZACHARY YOUNG 12/26/26
12/26/26
DITMAN STREET
DEVEREAUX AVENUE TO MCKINLEY STREET
20240121491
5 41
G2024-00104
M A
TC
H
LI
N
E
SE
E
SH
EE
T
W -8H
H
DITMAN STREET
PARKING
NO PARKING
PARKING
NO PARKING
M C
K
IN
LE
Y
ST
PARKING
N O
P
AR
KI
N
G
PA
RK
IN
G
NO PARKING
D
EV
ER
EA
U X
A
VE
PA
RK
IN
G
NO PARKING
PA
RK
IN
G
NO PARKING
Water 48"Water 30"
Water 8" Water 12"
Hydrant 6"
Verizon 9"x9" Gas 12" Gas 12"
Gas 6"
PROP. 12"X8" CROSS
PROP. 12"X12" TEEPROP. 12"X6" TEE
Sewer 4'-6" x 3'-0" Br.
TRANSMISSION MAIN
CROSSING DETAIL
SCALE 18" = 1'-0"
PROP. 12" D.I WATER MAIN,
(SEE CROSSING DETAIL THIS SHEET)
THE CONTRACTOR SHALL MAINTAIN A MINIMUM 18-INCH
VERTICAL CLEARANCE WHEN CROSSING UNDER ACTIVE
WATER TRANSMISSION MAINS (16" MAINS AND LARGER).
PROP. 30" D.I. WATER MAIN
333333
David.Weld Dtw w date Stamp zachary.young Text Box
FINAL DESIGN ONE CALL NO.
zachary.young Line zachary.young
20263060767, 20263060768, 20263060769
18"
12" 12"
12"
6"
.0087
.0087
.0
.0
.0
.0
.0087
.0087
L
L
STUMP
G
V
W
V
V
C.
D
/W De p.
C ur b
V G
W
W
W V V
G
V
V
G
W W
G
V W
G V
TS
W V
W
G W
V
G B B B
V V
G G V? ?
GW
V G G
B B B V
V G G
G
V W ? V G G
G V
V
VVWW
G G
VVV
WGW
G
TS
V
TS
WV
V
GG
STUMP
WV
TS
V V
2 Sty. Brick Row Houses
2 Sty. Brick Row Houses
2 Sty. Brick Row
Houses 2 Sty. Brick
Row Houses
St y.
B ric k
Ro w
H ou se s
#3
3 4
3'-6"
6'-0"
7'-0"
10'-0"
6'-0"
3'-6"
10'-0"
7'-0"
3'-6"
17'-0" 12'-0"
17'-0" 3'-6"
3'-5"
12'-0"
Gas 6", 3'-0" Cov.
Water 12", 4'-0" Cov.
Sewer 2'-6" x 1'-8" Br. 9'-1"± Cov.
Gas 6", 3'-0" Cov.
Water 12", 4'-0" Cov.
Sewer 2'-6" x 1'-8" Br. 9'-1"± Cov.
Water 6", 3'-1" Cov.
(TO BE ABAND.)
PROP. 8" D.I. WATER MAIN, 4'-0" COVER
Gas 6", 3'-6" Cov.
Water 6", 3'-8" Cov.
Sewer 2'-6" x 1'-8" Br. 9'-0"± Cov.
Sewer 2'-6" x 1'-8" Br. 8'-7"± Cov.
(TO BE ABAND.)
15'-0"
SECTION L - LREMOVE FRAME & COVER - SEE SPEC'S.
REMOVE FIRE HYDRANT - SEE SPEC'S.
REMOVE PIPE AND/OR FITTING & RECONNECT.
4 ROTATE FITTINGS AS REQUIRED.
5 REMOVE & RETURN VALVE - SEE SPEC'S.
NOTES:
1. EXISTING WATER MAINS SHALL BE CUT & PLUGGED AS
APPROVED BY THE CITY ENGINEER.
2. THE CONTRACTOR SHALL MAINTAIN A MINIMUM 6-INCH
CLEARANCE BETWEEN ALL UNDERGROUND STRUCTURES AND
THE NEW WATER MAINS.
3. BILLS OF MATERIAL AND PIPE TOTALS ARE FOR THE
CONVENIENCE OF THE CONTRACTOR ONLY AND PAYMENT WILL
BE MADE ONLY FOR THE ACTUAL AMOUNT OF PIPE AND
APPURTENANCES INSTALLED.
4. FIRE HYDRANTS SHALL NOT BE CONSTRUCTED OR RELOCATED
UNTIL SUCH LOCATIONS HAVE BEEN APPROVED BY THE WATER
DEPARTMENT CONSTRUCTION DIVISION IN THE FIELD.
5. ALL DISTANCES SHOWN ARE IN DISTRICT STANDARD
MEASUREMENTS
BILL OF MATERIALS
1 STD. FIRE HYDRANT W/CCL
2 STD. 7" VALVE BOX(ES)
1 8" VALVE(S)
1 6" VALVE(S)
1 12"X8" TEE(S)
1 8"X6" TEE(S)
4 12" 1/8 BENDS (0 VERTICAL)
2 8" 1/8 BENDS (2 VERTICAL)
2 6" 1/8 BENDS (2 VERTICAL)
2 12" SLEEVE(S)
PIPE TOTALS (THIS SHEET)
30' ± 12" DUCTILE IRON WATER MAIN
335' ± 8" DUCTILE IRON WATER MAIN
10' ± 6" DUCTILE IRON WATER MAIN
APPROVED
CHIEF, DESIGN BRANCH, ENGINEERING DIVISION
DRAWN BY
PROJECT ENGR.
SUPERVISOR DATE
WORK NO.
SHEET NO. OF
CITY OF PHILADELPHIA
WATER DEPARTMENT
WATER MAIN RELAY PROJECT
PURSUANT TO THE REQUIREMENTS OF PENNSYLVANIA ACT 287 OF 1974 (THE UNDERGROUND UTILITY
LINE PROTECTION ACT), AS AMENDED BY PA ACT 121 OF 2008, THE CONTRACTOR
SHALL CONTACT THE PENNSYLVANIA ONE CALL SYSTEM AT 1-800-242-1776, AT LEAST
3 DAYS PRIOR TO EXCAVATION.
HIGHWAY DISTRICT NO. WARD NO.
SURVEY DISTRICT NO.
ONE CALL SERIAL NO.
NOTICE:
WATER PLATE NO.
FROM
SCALES:
PLAN 1" = 20'
AND AS NOTED
W-10
GPIS NO.
g\ ap pd at a\ lo ca l\t em p\
Ac Pu bl ish
_1
\W at er
Sh ee ts .d w g\
W
By : Z
AC
H
AR
Y.
YO
U
N G
/6
/2
CS
V
1.
SHEETS
W-20417-DG
ZACHARY YOUNG
ZACHARY YOUNG 12/26/26
12/26/26
MARSDEN STREET
BENNER STREET TO 306' W OF DEVEREAUX AVE.
20240121521
5 41
G2024-00104
M A
TC
H
LI
N
E
SE
E
SH
EE
T
W -1
J
J
MARSDEN STREET
PARKING
NO PARKINGPARKING
NO PARKING
B
EN
N
ER
S T.
PA
RK
IN
G
NO PARKING
PA
RK
IN
G
NO PARKING
333333
David.Weld Dtw w date Stamp zachary.young Text Box
FINAL DESIGN ONE CALL NO.
zachary.young Line zachary.young
20263060830, 20263060831
12" 12"
12"
12" 8" 12"
12"12"
STUMP
24"
.0087
.0087 .0087
.0087
.0
.0
.0
.0
.0066
.0063
M
M
G G V W G
G G
V
W V G G V W V W
VW
G
W
G
VV
W
V
V G ?VV?GW
V
?V G
G
V
W
6"
G
G V V
W
V
G
W
V
2 Sty. Brick Row Houses
2 Sty. Brick Row Houses
St y.
B ric k
Ro w
H ou se s
St y.
B ric k
Ro w
H ou se s
St y.
B ric k
Ro w
H ou se s
St y.
B ric k
Ro w
H ou se s
#3
#3#3
Gas 12", 3'-9" Cov.
4'-6"
10'-4" 1'-0"
6'-0"
12'-6" 17'-0" 1'-6"
6'-0"
3'-6"
5'-4"
1'-6"
17'-0"
6'-0" 5'-0"
10'-0" 7'-0"
4'-6" 11'-0"
1'-4"
8'-0"
12'-6"
3'-6"
7'-0"
10'-0" 6-0"
3'-6"
Water 6", 3'-8" Cov.
(TO BE ABAND.)
Gas 6", 3'-0" Cov.
Sewer 2'-6" x 1'-8" Br. 9'-3"± Cov.
PROP. 8" D.I. WATER MAIN, 4'-0" COVER
Sewer 2'-6" x 1'-8" Br. 9'-8"± Cov.
Verizon 9" x 13", 3'-0" Cov.
Verizon 5" x 5", Unk. Cov.
Verizon 5" x 5", 2'-2" Cov.
Sewer 4'-6" x 3'-0" Br. 8'-5"± Cov.
Water 6", 3'-7" Cov.
Water 30", 2'-0" Cov.
Verizon 9" x 9", 3'-7" Cov.
Water 48", 2'-6" Cov.
Gas H.P. 12", 4'-0" Cov.
Gas 6", 3'-0" Cov.
Gas 6", 3'-2" Cov.
Water 8", 4'-0" Cov.
Sewer 18" Dia. RCP, 8'-3"± Cov.
Sewer 12" Vent
Water 6", 6'-5" Cov.
Water 48", 2'-6" Cov.
Sewer 4'-6" x 3'-0" Br. 8'-8"± Cov.
Gas 6", 3'-0" Cov.
Verizon 9" x 9", 3'-0" Cov.
Water 30", 2'-0" Cov.
Water 8", 5'-6" Cov.
Gas H.P. 12" , 3'-9" Cov.
PROPOSED GSI TRENCH
(SEE SHEET G-5)
(TO BE ABAND.)8'-0"
9'-0"
PROP. 30" D.I. WATER MAIN (SEE SPEC)
7'-10"
(SEE SPEC.)
SECTION M - M
1' -6
REMOVE FRAME & COVER - SEE SPEC'S.
REMOVE FIRE HYDRANT - SEE SPEC'S.
REMOVE PIPE AND/OR FITTING & RECONNECT.
4 ROTATE FITTINGS AS REQUIRED.
5 REMOVE & RETURN VALVE - SEE SPEC'S.
NOTES:
1. EXISTING WATER MAINS SHALL BE CUT & PLUGGED AS
APPROVED BY THE CITY ENGINEER.
2. THE CONTRACTOR SHALL MAINTAIN A MINIMUM 6-INCH
CLEARANCE BETWEEN ALL UNDERGROUND STRUCTURES AND
THE NEW WATER MAINS.
3. BILLS OF MATERIAL AND PIPE TOTALS ARE FOR THE
CONVENIENCE OF THE CONTRACTOR ONLY AND PAYMENT WILL
BE MADE ONLY FOR THE ACTUAL AMOUNT OF PIPE AND
APPURTENANCES INSTALLED.
4. FIRE HYDRANTS SHALL NOT BE CONSTRUCTED OR RELOCATED
UNTIL SUCH LOCATIONS HAVE BEEN APPROVED BY THE WATER
DEPARTMENT CONSTRUCTION DIVISION IN THE FIELD.
5. ALL DISTANCES SHOWN ARE IN DISTRICT STANDARD
MEASUREMENTS
PIPE TOTALS (THIS SHEET)
20' ± 30" DUCTILE IRON WATER MAIN
375' ± 8" DUCTILE IRON WATER MAIN
20' ± 6" DUCTILE IRON PIPE MAIN
APPROVED
CHIEF, DESIGN BRANCH, ENGINEERING DIVISION
DRAWN BY
PROJECT ENGR.
SUPERVISOR DATE
WORK NO.
SHEET NO. OF
CITY OF PHILADELPHIA
WATER DEPARTMENT
WATER MAIN RELAY PROJECT
PURSUANT TO THE REQUIREMENTS OF PENNSYLVANIA ACT 287 OF 1974 (THE UNDERGROUND UTILITY
LINE PROTECTION ACT), AS AMENDED BY PA ACT 121 OF 2008, THE CONTRACTOR
SHALL CONTACT THE PENNSYLVANIA ONE CALL SYSTEM AT 1-800-242-1776, AT LEAST
3 DAYS PRIOR TO EXCAVATION.
HIGHWAY DISTRICT NO. WARD NO.
SURVEY DISTRICT NO.
ONE CALL SERIAL NO.
NOTICE:
WATER PLATE NO.
FROM
SCALES:
PLAN 1" = 20'
AND AS NOTED
W-11
GPIS NO.
g\ ap pd at a\ lo ca l\t em p\
Ac Pu bl ish
_1
\W at er
Sh ee ts .d w g\
W
AC
H
AR
Y.
YO
U
N G
/6
/2
CS
V
1.
SHEETS
W-20417-DG
ZACHARY YOUNG
ZACHARY YOUNG 12/26/26
12/26/26
MARSDEN STREET
306' W OF DEVEREAUX AVE. TO DEVEREAUX AVE.
20240121521
5 41
G2024-00104
M A
TC
H
LI
N
E
SE
E
SH
EE
T
W -1
J
J
MARSDEN STREET
PARKING
NO PARKINGPARKING
NO PARKING
D
EV
ER
EA
U X
A
VE
PA
RK
IN
G
NO PARKING
PA
RK
IN
G
NO PARKING
THE CONTRACTOR SHALL MAINTAIN A MINIMUM 18-INCH
VERTICAL CLEARANCE WHEN CROSSING UNDER ACTIVE
WATER TRANSMISSION MAINS (16" MAINS AND LARGER).
BILL OF MATERIALS
2 STD. FIRE HYDRANT W/CCL
6 STD. 7" VALVE BOX(ES)
4 8" VALVE(S)
2 6" VALVE(S)
2 8"X6" HYDRANT ANCHOR TEE(S)
2 8"X8" TEE(S)
18 8" 1/8 BENDS (14 VERTICAL)
2 6" 1/8 BENDS (0 VERTICAL)
1 8"X6" REDUCER(S)
2 8" SLEEVE(S)
1 6" SLEEVE(S)
2 30" MECHANICAL COUPLINGS
Verizon Manhole
TRANSMISSION MAIN
CROSSING DETAIL
SCALE 18" = 1'-0"
Gas 6"
Gas 12"Water 6"Verizon 9"x13" Verizon 9"x9"
Sewer 4'-6" x 3'-0" Br.
Water 48"
Approx. Surface
PROP. 8" WATER MAIN
PROP. 8"X8" TEE
VALVE 8"
PROP. 8" D.I. WATER MAIN
(SEE CROSSING DETAIL THIS SHEET)
PROP. 30" WATER MAIN
333333
David.Weld Dtw w date Stamp zachary.young Text Box
FINAL DESIGN ONE CALL NO.
zachary.young Line zachary.young
20263060830, 20263060831
Water 48" Gas 6"
Gas 12" HP
Water 30"
Sewer 3'-6"x2'-4" Br.
Sewer 4'-6"x3'-0" Br.
Verizon 5"x5"
Gas 6"
PROP. 24" WATER MAIN
PROP. 12" WATER
Water 12"
PROP. 24"X12" R.C.
PROP. 2" AIR VALVE W/ CHAMBER
Water 60" Steel
Water 24"
Sewer 21" RCP
Water 12"
PROP. 24" GATE VALVE
PROP. 24"X12" TEE
PROP. 24" WATER MAIN
PROP. ZAYO 2"
45° HORIZ. BEND
PROP. 24"X6" TEE
1' -6
"2' -0
NOTES:
1. EXISTING WATER MAINS SHALL BE CUT & PLUGGED AS
APPROVED BY THE CITY ENGINEER.
2. THE CONTRACTOR SHALL MAINTAIN A MINIMUM 6-INCH
CLEARANCE BETWEEN ALL UNDERGROUND STRUCTURES AND
THE NEW WATER MAINS.
3. BILLS OF MATERIAL AND PIPE TOTALS ARE FOR THE
CONVENIENCE OF THE CONTRACTOR ONLY AND PAYMENT WILL
BE MADE ONLY FOR THE ACTUAL AMOUNT OF PIPE AND
APPURTENANCES INSTALLED.
4. FIRE HYDRANTS SHALL NOT BE CONSTRUCTED OR RELOCATED
UNTIL SUCH LOCATIONS HAVE BEEN APPROVED BY THE WATER
DEPARTMENT CONSTRUCTION DIVISION IN THE FIELD.
5. ALL DISTANCES SHOWN ARE IN DISTRICT STANDARD
MEASUREMENTS
APPROVED
CHIEF, DESIGN BRANCH, ENGINEERING DIVISION
DRAWN BY
PROJECT ENGR.
SUPERVISOR DATE
WORK NO.
SHEET NO. OF
CITY OF PHILADELPHIA
WATER DEPARTMENT
WATER MAIN RELAY PROJECT
PURSUANT TO THE REQUIREMENTS OF PENNSYLVANIA ACT 287 OF 1974 (THE UNDERGROUND UTILITY
LINE PROTECTION ACT), AS AMENDED BY PA ACT 121 OF 2008, THE CONTRACTOR
SHALL CONTACT THE PENNSYLVANIA ONE CALL SYSTEM AT 1-800-242-1776, AT LEAST
3 DAYS PRIOR TO EXCAVATION.
HIGHWAY DISTRICT NO. WARD NO.
SURVEY DISTRICT NO.
ONE CALL SERIAL NO.
NOTICE:
WATER PLATE NO.
FROM
SCALES:
PLAN 1" = 20'
AND AS NOTED
W-12
GPIS NO.
g\ ap pd at a\ lo ca l\t em p\
Ac Pu bl ish
_1
\W at er
Sh ee ts .d w g\
W
AC
H
AR
Y.
YO
U
N G
/6
/2
CS
V
1.
SHEETS
W-20417-DG
ZACHARY YOUNG
ZACHARY YOUNG 12/26/26
12/26/26
PROFILE OF 24" TRANSMISSION MAIN IN COTTAGE ST.
DEVEREAUX AVE. TO ROBBINS ST.
20240121521
5 41
G2024-00104
M A
TC
H
LI
N
E
SE
E
SH
EE
T
TH
IS
S H
EE
T
B B
M A
TC
H
LI
N
E
SE
E
SH
EE
T
TH
IS
S H
EE
T
B B
COTTAGE STREET
PARKING
NO PARKING
PARKING
NO PARKING
TRANSMISSION MAIN CROSSING DETAIL FOR 8" MAIN IN WALKER STREET (W-1)
SCALE 14" = 1'-0"
PROP. 8" WATER MAIN
PROP 8"X8" TEEPROP 8"X8" TEE
Water 6"Gas 12" HP Water 48"Verizon 10"x10"Verizon 10"x10"(Unk. Cov.)
Water 30"
Water 6"
Gas 8"
(TO BE FILLED AND ABAND.)
Sewer 3'-6" x 2'-4" Br.
VERTICAL SCALE
1" = 5'-0"
VERTICAL SCALE
1" = 5'-0"
45° HORIZ. BEND
333333
David.Weld Dtw w date Stamp zachary.young Text Box
FINAL DESIGN ONE CALL NO.
zachary.young Line zachary.young
20263060736, 20263060737, 20263060714, 20263060715
X
X X
X
Services, Ltd.
CorTrol
Z Z
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DD
AutoCAD SHX Text
SUPERVISOR
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
CORROSION CONTROL PLAN
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
CORTROL SERVICES, LTD.
AutoCAD SHX Text
SCALE: 1"=20'-0"
AutoCAD SHX Text
CITY OF PHILADELPHIA
AutoCAD SHX Text
WATER DEPARTMENT
AutoCAD SHX Text
6" & 8" DUCTILE IRON WATER MAINS
AutoCAD SHX Text
IN
AutoCAD SHX Text
DEVEREAUX AVENUE
AutoCAD SHX Text
FROM
AutoCAD SHX Text D1339-1
AutoCAD SHX Text
WALKER ST. ALGARD ST.
AutoCAD SHX Text
TO
AutoCAD SHX Text
GG
AutoCAD SHX Text 7/8/26
AutoCAD SHX Text
WORK NO. W-20417-DG
AutoCAD SHX Text SHEET NO. W-13 of 24 SHEETS
AutoCAD SHX Text 7/8/26
AutoCAD SHX Text 2929 Avebury Stone Circle
AutoCAD SHX Text Downingtown, Pennsylvania 19335
AutoCAD SHX Text Drawing prepared by:
AutoCAD SHX Text Office: (484) 378-7996
AutoCAD SHX Text
COLD APPLIED BITUMASTIC COATING (FAST DRYING).
AutoCAD SHX Text
32 LB. MAGNESIUM ANODE PREPACKAGED IN CLOTH OR PAPER BAG, TOTAL WEIGHT 70 LBS.
AutoCAD SHX Text
MATERIALS LIST - CORROSION CONTROL
AutoCAD SHX Text
AWG NO. 4 STRANDED COPPER WIRE WITH TYPE THW 600 VOLT INSULATION.
AutoCAD SHX Text
AWG NO. 8 STRANDED COPPER WIRE WITH TYPE THW 600 VOLT INSULATION.
AutoCAD SHX Text 5-INCH NOMINAL DIAMETER VALVE BOX, UPPER SECTION WITH COVER. BINGHAM & TAYLOR NO. 55-S WITH FLANGE OR EQUAL.
AutoCAD SHX Text STEEL TEST ELECTRODE, 1/2 INCH DIA. X 6 INCH LONG STEEL BAR WITH 15 FT. OF NO. 8 STRANDED COPPER WIRE WITH WHITE HMWPE INSULATION.
AutoCAD SHX Text ZINC REFERENCE ELECTRODE, 1.4 INCH X 1.4 INCH X 9 INCH PACKAGED IN BACKFILL WITH 15 FT. OF AWG NO. 8 WIRE WITH RED HMWPE INSULATION.
AutoCAD SHX Text
THERMITE WELDING EQUIPMENT CHARGES AND MOLDS SUITABLE FOR NO. 4, AND NO. 8 WIRE.
AutoCAD SHX Text QUANTITIES OF MATERIALS AND EQUIPMENT SHOWN ON THIS DRAWING ARE FOR THE CONVENIENCE OF THE CONTRACTOR ONLY AND DOES NOT RELIEVE HIM OF THE RESPONSIBILITY TO FURNISH AND INSTALL ALL MATERIALS AND EQUIPMENT NECESSARY TO COMPLETE THE WORK.
AutoCAD SHX Text
NOTE:
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
STUART STEEL SOMERSET, NJ
AutoCAD SHX Text
AS REQ'D.
AutoCAD SHX Text
AS REQ'D.
AutoCAD SHX Text
STUART STEEL SOMERSET, NJ
AutoCAD SHX Text
STUART STEEL SOMERSET, NJ
AutoCAD SHX Text
STUART STEEL SOMERSET, NJ
AutoCAD SHX Text
STUART STEEL SOMERSET, NJ
AutoCAD SHX Text
STUART STEEL SOMERSET, NJ
AutoCAD SHX Text
STUART STEEL SOMERSET, NJ
AutoCAD SHX Text
STUART STEEL SOMERSET, NJ
AutoCAD SHX Text
AutoCAD SHX Text
AS REQ'D.
AutoCAD SHX Text
AS REQ'D.
AutoCAD SHX Text
AutoCAD SHX Text 177' ±
AutoCAD SHX Text 331' ±
AutoCAD SHX Text INFORMATION SHOWN ON CORROSION CONTROL PLANS TO BE USED FOR GENERAL POSITIONING OF THE CORROSION CONTROL SYSTEM. THE ACTUAL INSTALLATION OF ALL CORROSION CONTROL ITEMS SHALL CONFORM TO P.W.D. STD. DWG. NOS.
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .