Plans.pdf
PDF 9 MB Posted
- Attached to
- Carlton Wellfield Improvements- 16 Wells
- Solicitation number
- 262906RM
- Issued by
- Sarasota County, Siesta Key CDP, Florida
About this file
This file contains construction plans for the Carlton Wellfield Improvements project involving 16 production wells in Florida. The plans document the technical specifications and design requirements for the well rehabilitation services that will be performed under the Major Construction Contract. The project scope includes detailed engineering drawings and site plans necessary for contractors to understand the physical layout, existing well configurations, and proposed improvements to the water production facilities.
The plans serve as essential bid documents that establish the technical standards and construction methodologies required for the rehabilitation work. Prospective bidders must review these plans in conjunction with the solicitation documents to develop accurate proposals and cost estimates for the well rehabilitation services. The plans provide the detailed specifications that contractors will need to follow during construction to ensure the wells meet county standards and operational requirements upon project completion.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PLANS
FOR
CONSTRUCTION PLANS
VICINITY MAP
SCALE: NTS
GENERAL
CIVIL
MECHANICAL
STRUCTURAL
STEVEN KING, PE
NO. 74954
INSTRUMENTATION JEFFREY S. MILLER, PE
NO. 96128
REGISTERED ENGINEERS STATE OF FLORIDA
Black & Veatch Corporation Business License No. F-0794
4210 Metro Parkway, Suite 200 Fort Myers, Florida 33916
Certificate No. 8132
SARASOTA COUNTY, FLORIDA
JANUARY 2026
SARASOTA COUNTY CIP # 88094
CARLTON WELLFIELD REHABILITATION
G-00 OF
100% ISSUED FOR
BID
SARASOTA COUNTY COMMISSIONERS
DISTRICT 1 - TERESA MAST
DISTRICT 2 - MARK SMITH
DISTRICT 3 - TOM KNIGHT
DISTRICT 4 - DR. JOE NEUNDER
DISTRICT 5 - RON CUTSINGER
PROJECT TEAM
OWNER:
SARASOTA COUNTY
1001 SARASOTA CENTER BOULEVARD
SARASOTA, FL, 34240
CONTACT: JEREMY PARKER
941-875-8506
ENGINEER:
BLACK & VEATCH
4210 METRO PARKWAY, SUITE 200
FORT MYERS, FL, 33916
CONTACT: STEVEN KING, P.E.
813-207-7958
UTILITY CONTACTS
MABRY CARLTON WATER TREATMENT PLANT
1255 N MABRY CARLTON PKWY
VENICE, FL 34292
CONTACT: RICHARD BUNN
941-861-1500
SARASOTA COUNTY UTILITIES DEPARTMENT
1001 SARASOTA CENTER BOULEVARD
SARASOTA, FL, 34240
CONTACT: CLIFF HARRISON
941-396-0932
FLORIDA POWER & LIGHT
1253 12TH AVENUE EAST
PALMETTO, FL, 34221
CONTACT: JAMIE PURNELL
386-586-6403
CONSTRUCTION PERMITS:
FLORIDA DEPARTMENT OF ENVIRONMENTAL PROTECTION:
APPLICATION TO CONSTRUCT, REPAIR, MODIFY OR ABANDON A WELL
FORM 62-532.900_1 (CONTRACTOR TO OBTAIN)
STORMWATER POLLUTION PREVENTION PLAN
*ALL CONSTRUCTION ON THIS PROJECT SHALL BE IN ACCORDANCE WITH THE SARASOTA COUNTY UTILITY
MANUAL DATED 11/16/2023
PREPARED BY
FLORIDA LAW REQUIRES
EXCAVATORS TO NOTIFY
OWNERS OF UNDERGROUND
FACILITIES NO LESS THAN TWO
(2) DAYS PRIOR TO EXCAVATION
SITE LOCATION
SHEET LIST TABLE
G-00 G-01 G-02 C-01 C-02 C-03 C-04 M-01 S-01 I-01 I-02 I-03 I-04
GENERAL - COVER AND SHEET LIST
GENERAL - NOTES
GENERAL - OVERALL SITE MAP AND GENERAL LEGEND
CIVIL - DEMOLITION DETAILS
PERMANENT LAYDOWN AREA DETAIL
CIVIL AND PIPING DETAILS
CIVIL - EROSION CONTROL DETAILS
MECHANICAL - TYPICAL SECTION AND PRODUCTION WELL DETAILS
STRUCTURAL - DETAILS
I&C - LEGEND & ABBREVIATIONS
I&C - WELL FIELD TYPICAL P&ID
I&C - CONTROL BLOCK DIAGRAM AND DETAILS
I&C - FIBER RING TOPOLOGY
This item has been digitally signed and sealed by Steven King and Jeffrey Miller on thee dates indicated here.
Printed copies of this document are not considered signed and sealed and the signature must be verifies on any electronic copies.
01-30-2026
King, Steven E.
Digitally signed by King, Steven E.
Date: 2026.01.30 16:02:03-05'00'
GENERAL NOTES
1. THE INFORMATION PROVIDED IN THESE PLANS IS TO ASSIST THE CONTRACTOR IN ASSESSING THE NATURE AND EXTENT OF THE CONDITIONS WHICH MAY BE ENCOUNTERED DURING THE COURSE OF THE WORK. ALL CONTRACTORS ARE DIRECTED, PRIOR TO PRICING PROJECT, TO CONDUCT WHATEVER INVESTIGATIONS THEY DEEM NECESSARY TO ARRIVE AT THEIR OWN CONCLUSIONS REGARDING THE ACTUAL CONDITIONS THAT WILL BE ENCOUNTERED, AND UPON
WHICH, PRICING OF THE PROJECT WILL BE BASED.
2. CALL BEFORE YOU DIG. CONTRACTOR SHALL VERIFY PRECISE LOCATIONS AND ELEVATIONS OF ALL UTILITIES AND STRUCTURES, WHETHER INDICATED ON THE DRAWINGS OR NOT, IN THE FIELD IN ADVANCE OF EXCAVATING, BY CONTACTING ALL UTILITIES AND OTHER AGENCIES, AND BY PROSPECTING. CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL, DEMOLITION, RECONSTRUCTION, AND RECONNECTION OF EXISTING FACILITIES AS REQUIRED TO COMPLETE THE WORK. IF REQUIRED AFTER FIELD VERIFICATION, CONTRACTOR SHALL COORDINATE WITH THE ENGINEER TO
DETERMINE ANY NECESSARY MODIFICATIONS TO NEW WORK.
3. BEFORE CONSTRUCTION IS STARTED, CONTRACTOR SHALL COORDINATE WITH THE OWNER OF EACH UTILITY AND DEFINE THE REQUIREMENTS AND METHODS TO ACCOMMODATE THE PROTECTION, TEMPORARY SUPPORT, ADJUSTMENT, OR RELOCATION OF ANY UTILITIES AFFECTED BY THE NEW WORK.
4. CONTRACTOR SHALL FILE THE NOTICE OF INTENT AND COMPLETE A STORMWATER POLLUTION PREVENTION PLAN IN ACCORDANCE WITH THE FDEP NPDES CONSTRUCTION REQUIREMENTS AND SHALL PROVIDE APPROPRIATE MITIGATION MEASURES OR PROTECTION AND RESTORATION AT ALL LOCATIONS AS REQUIRED BY THEIR OPERATIONS, AND AS DIRECTED BY ENGINEER. SPECIAL MINIMUM CONSTRUCTION REQUIREMENTS, TEMPORARY PROTECTIVE FENCING OR
BARRICADES, SHEETING, SHORING, EROSION PROTECTION, AND SURFACE RESTORATION.
5. CONTRACTOR SHALL INSTALL ALL PIPELINES AT A UNIFORM GRADE BETWEEN ELEVATIONS.
6. THE CONTRACTOR'S OPERATIONS SHALL CONFORM TO THE RULES AND REGULATIONS OF OSHA AND THE STATE
CONSTRUCTION SAFETY ORDERS PERTAINING TO EXCAVATION AND TRENCHING.
7. WHERE SPECIAL EXCAVATION ZONES ARE REQUIRED FOR THE WORK, CONTRACTOR SHALL INSTALL EXCAVATION SUPPORT SYSTEMS TO PROTECT EXISTING PIPES OR STRUCTURES. CONTRACTOR TO VERIFY EXACT LOCATION AND MATERIAL OF EXISTING PIPES WITHIN THE EXCAVATION ZONE. THE SYSTEM SHALL BE DESIGNED AND SEALED BY A
FLORIDA REGISTERED ENGINEER IN GOOD STANDING AND SHALL BE SUBMITTED FOR RECORDS.
8. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO EXISTING FACILITIES AS A RESULT OF CONTRACTOR'S OPERATIONS AND SHALL HAVE ON SITE SUFFICIENT MATERIALS AND EQUIPMENT TO IMMEDIATELY
REPAIR AND DAMAGE TO EXISTING FACILITIES.
9. ALL NEW VALVES BEING INSTALLED SHALL REMAIN CLOSED DURING CONSTRUCTION. DO NOT CONNECT ANY
PROPOSED WATER MAIN TO ANY EXISTING WATER MAIN UNLESS CLEARED BY UTILITIES.
10. ALL BELOW GRADE PIPING SHALL HAVE A MINIMUM COVER OF 36 INCHES, UNLESS OTHERWISE NOTED.
11. ALL BELOW GRADE PIPING CONNECTIONS TO TRANSMISSION LATERALS SHALL HAVE RESTRAINED JOINTS.
12. PIPE DEFLECTION SHALL NOT BE GREATER THAN 50% OF MANUFACTURERS RECOMMENDED DEFLECTION.
13. THE CONTRACTOR SHALL ENSURE THAT CONSTRUCTION ACTIVITIES DO NOT ADVERSELY IMPACT EXISTING DRAINAGE SYSTEMS. IF DRAINAGE SYSTEMS ARE AFFECTED DURING THE WORK, THEY SHALL BE TEMPORARILY RECONFIGURED TO MAINTAIN EFFICIENT SURFACE WATER DRAINAGE AND PREVENT ANY REDUCTION IN DRAINAGE CAPACITY. ALL WORK MUST COMPLY WITH THE REQUIREMENTS OF THE APPROVED STORMWATER POLLUTION PREVENTION PLAN
(SWPPP) FOR THE PROJECT.
14. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING A DEWATERING PERMIT FROM THE SOUTHWEST FLORIDA
WATER MANAGEMENT DISTRICT IF NECESSARY.
15. WELLS TO BE CONSTRUCTED ACCORDING TO AWWA A100, LATEST EDITION. WELLS SHALL BE DISINFECTED PER AWWA
STANDARDS.
16. ALL PIPE AND FITTINGS SHALL CARRY THE NATIONAL SANITATION FOUNDATION (NSF) SEAL OF APPROVAL FOR POTABLE WATER APPLICATIONS. ANY MATERIALS TO BE IN CONTACT WITH THE RAW WATER SHALL ALSO BE APPROVED FOR USE
BY NSF.
17. WHERE THE WORK IS IN PROXIMITY OF EXISTING UTILITIES, CONTRACTORS SHALL MAINTAIN VERTICAL AND HORIZONTAL SEPARATION PER FDEP SEPARATION REQUIREMENTS FOR RAW WATER LINES NEAR POTABLE, SANITARY, OR STORM LINES WHICH MAY BE PRESSURE, GRAVITY, OR VACUUM.
18. THE CONTRACTOR SHALL PREPARE A SITE SPECIFIC SURVEY AND AN AS-BUILT DRAWING FOR EACH REHABILITATED PRODUCTION WELL (16 IN TOTAL) AS A PART OF THE CONSTRUCTION SCOPE. THESE DRAWINGS MUST INCLUDE THE GENERAL WELL CONFIGURATION AND ALL SITE-SPECIFIC DETAILS, SUCH AS THE CONNECTION FROM THE WELL TO THE TRANSMISSION MAIN, PIPING ELEVATIONS, VALVES, WELLHEADS, ELEVATION CHANGES, AND CONCRETE PEDESTALS.
19. THE CONTRACTOR SHALL MAINTAIN REDLINED DRAWINGS FOR THE WORK ACCURATELY SHOWING ANY DEVIATIONS. A COPY OF THESE REDLINED DRAWINGS SHALL BE PROVIDED TO THE ENGINEER PRIOR TO SUBSTANTIAL COMPLETION
AND PRIOR TO REQUESTING FDEP CLEARANCE FOR SERVICE.
20. COORDINATES INDICATED ON THE DRAWINGS ARE STATE PLANE COORDINATE SYSTEM, FLORIDA WEST ZONE, NORTH AMERICAN DATUM 2011 (NAD 83). ELEVATIONS INDICATED ON THE DRAWINGS ARE BASED ON NORTH AMERICAN
VERTICAL DATUM 1988 (NAVD 88).
21. CONTRACTOR LAYDOWN AREA IS LOCATED AT EACH PRODUCTION WELL, ENCLOSED BY AN EXISTING FENCE.
CONTRACTOR TO TEMPORARILY REINFORCE SECURITY OF EACH WELL AND INCORPORATE NO TRESPASSING SIGNS DURING CONSTRUCTION. IF THE EXISTING PERMANENT FENCE CONFLICTS WITH THE RAW WATER TRANSMISSION MAN
(RWTM) CONNECTION, TEMPORARILY REMOVE AND REINSTALL AT THE END OF THE PROJECT.
22. STANDARD HOURS OF WORK ARE 8 AM TO 5 PM MONDAY-FRIDAY, AFTER HOURS WORK NEED TO BE APPROVED IN
ADVANCE BY THE OWNER.
23. CONTRACTOR TO COORDINATE CONSTRUCTION SCHEDULE WITH ON SITE FIRE MITIGATION SPECIALIST TO MINIMIZE
CONSTRUCTION IMPACTS.
24. CONTRACTOR TO CHECK IN/OUT AT THE CARLTON WTP MAIN OFFICE EVERY TIME THEY INGRESS/EGRESS THE
FACILITY.
25. CONTRACTOR SHALL COMPLY WITH THE GOVERNING AGENCY NPDES CONSTRUCTION REQUIREMENTS, AND SHALL PROVIDE APPROPRIATE MITIGATION MEASURES OR PROTECTION AND RESTORATION AT ALL LOCATIONS AS REQUIRED BY THEIR OPERATIONS, AND AS DIRECTED BY ENGINEER; SPECIAL CONSTRUCTION REQUIREMENTS, TEMPORARY PROTECTIVE FENCING OR BARRICADES, SHEETING, SHORING, EROSION PROTECTION, AND SURFACE RESTORATION AT CERTAIN LOCATIONS ARE INDICATED ON THE DRAWINGS TO BRING CONTRACTOR’S ATTENTION TO SENSITIVE AREAS.
26. ALL PIPING SHALL BE PRESSURE TESTED AND LEAKAGE TESTED IN ACCORDANCE WITH APPLICABLE AWWA STANDARDS AND SPECIFICATION 02666, AND ALL PIPING SHALL BE FLUSHED AND DISINFECTED IN ACCORDANCE WITH AWWA C� 651, LATEST EDITION, AS NOTED IN SPECIFICATION 02675.
27. THE PROJECT SHALL BE CONSTRUCTED IN GROUPS AS NOTED IN THE CONTRACT DOCUMENTS TO ENSURE NECESSARY FLOW REQUIREMENTS PER THE SPECIFICATION ARE MET; PRIOR TO ANY WELL OR PIPELINE BEING PLACED BACK INTO SERVICE, THE SYSTEM MUST BE DISINFECTED, PRESSURE TESTED, AND CLEARED BY THE FLORIDA DEPARTMENT OF
ENVIRONMENTAL PROTECTION.
28. THE CONTRACTOR SHALL DEVELOP A STORM WATER POLLUTION PREVENTION PLAN (SWPPP) AND APPOINT A DESIGNATED SWPP INSPECTOR FOR THE PROJECT SITE; THE CONTRACTOR SHALL PAY FOR AND FILE A NOTICE OF INTENT TO USE THE STATE OF FLORIDA DEPARTMENT OF ENVIRONMENTAL PROTECTION GENERIC PERMIT AT THE
COMPLETION OF THE PROJECT.
29. THE DRAWINGS INDICATE TYPES OF PIPE SUPPORT SYSTEMS AT VARIOUS LOCATIONS; HOWEVER, ALL PIPE SUPPORTS, HANGERS, BRACKETS, INSERTS OR BRACES ARE NOT SHOWN; CONTRACTOR SHALL REFER TO THE SPECIFICATIONS
AND PROVIDE COMPLETE SUPPORT SYSTEMS AS REQUIRED.
30. CONTRACTOR SHALL NOT OPERATE ANY EXISTING VALVES; NECESSARY OPERATION OF EXISTING VALVES SHALL BE
COORDINATED WITH THE OWNER.
31. CONTRACTOR’S OPERATIONS SHALL BE LIMITED TO AREAS IN WHICH WORK IS TO BE PERFORMED; ACCESS TO OTHER
AREAS OF SITE SHALL BE COORDINATED WITH OWNER.
32. OPERATIONS AT THIS FACILITY ARE ONGOING AND, AS SUCH, ANY SHUTDOWNS REQUIRED BY THE WORK MUST BE COORDINATED WITH THE OWNER; OWNER SHUTDOWNS ARE INDICATED ACCORDING TO SPECIFICATIONS.
33. THE CONTRACTOR SHALL MAINTAIN AND REPAIR THE SITE ACCESS ROAD AT ALL TIMES DURING CONSTRUCTION IN
ACCORDANCE WITH THE CONTRACT DOCUMENTS.
34. ALL TEES, CROSSES, BENDS (HORIZONTAL AND VERTICAL), PLUGS, BURIED PIPING, AND ABOVEGROUND
APPURTENANCES SHALL BE INSTALLED WITH RESTRAINED JOINTS UNLESS OTHERWISE NOTED.
35. CONTRACTOR SHALL NOTE THE WELLFIELD IS KNOWN HABITAT FOR GOPHER TORTOISES; CONTRACTOR SHALL BE REQUIRED TO WORK WITH THE FLORIDA FISH AND WILDLIFE CONSERVATION COMMISSION (FWC) TO COMPLETE THE REQUIRED SURVEY, COMPLETE ANY NECESSARY PERMITTING AND RELOCATE OR OTHERWISE PROTECT THE
TORTOISES PRIOR TO ANY WORK COMMENCING ON SITE.
DEMOLITION NOTES
1. CONTRACTOR SHALL SUBMIT A DETAILED DEMOLITION PLAN INDICATING THE MAJOR DEMOLITION ACTIVITIES, PLANNED DATES, OWNER COORDINATION REQUIREMENTS, PERMIT REQUIREMENTS (IF ANY), AND ANY SPECIAL
PLANNING CONSIDERATIONS THAT REQUIRE COORDINATION WITH THIRD-PARTIES.
2. INCLUDES SALVAGE OF MATERIALS AND EQUIPMENT AS SPECIFIED IN DRAWINGS OR SPECIFICATIONS.
3. REQUIRES COORDINATION WITH THE OWNER TO ENSURE MINIMAL INTERFERENCE WITH OPERATIONS AND SAFETY OF
ACCESSIBLE AREAS DURING DEMOLITION ACTIVITIES.
4. BLASTING IS GENERALLY NOT PERMITTED UNLESS EXPLICITLY STATED.
5. REMOVAL INCLUDES ALL ACCESSORIES, PIPING, SUPPORTS, AND ASSOCIATED DEVICES UNLESS OTHERWISE DIRECTED. ALL DEMOLITION DEBRIS SHALL BE REMOVED FROM THE SITE AND LEGALLY DISPOSED OF.
6. MATERIALS NOT REUSED BECOME THE CONTRACTOR'S PROPERTY AND MUST BE DISPOSED OF OR RECYCLED PER
STATE LAWS.
7. PROTECTION MUST BE PROVIDED FOR FACILITIES REMAINING IN OPERATION, AND ANY DAMAGE MUST BE REPAIRED
TO ORIGINAL OR BETTER CONDITION.
8. ITEMS TO BE SALVAGED BY THE OWNER OR CONTRACTOR MUST BE CAREFULLY REMOVED AND STORED TO PREVENT
DAMAGE.
WELLFIELD REHABILITATION CONSTRUCTION SEQUENCE GENERAL NOTES
1. CONTRACTOR TO REHABILITATE WELLS IN PHASES. EACH PHASE BELOW CONSISTS OF WELL DOWNHOLE
REHAB AND SURFACE FACILITIES REHAB WORK.
2. THE CONTRACTOR SHALL REHABILITATE PRODUCTION WELLS IN FOUR SEQUENTIAL PHASES. EACH PHASE SHALL INCLUDE INSTALLATION OF AN ISOLATION GATE VALVE AND VALVE BOX, DOWNHOLE WELL
REHABILITATION, AND REHABILITATION OF ASSOCIATED SURFACE FACILITIES.
3. AT THE START OF EACH PHASE, THE CONTRACTOR SHALL INSTALL A BURIED GATE VALVE AND VALVE BOX TO CONTROL FLOW AND MINIMIZE WELLFIELD SHUTDOWNS. THE GATE VALVE SHALL BE INSTALLED TO ISOLATE
THE WELL PRIOR TO ANY REHABILITATION WORK.
4. BEFORE COMMENCING WORK, THE CONTRACTOR SHALL LOCATE, EXCAVATE, AND CONFIRM THE PIPE
LOCATION, MATERIAL, AND DIAMETER.
5. A TOTAL OF FOUR WELLFIELD SHUTDOWNS ARE ANTICIPATED. SHUTDOWNS SHALL BE COORDINATED WITH
THE OWNER AT LEAST THIRTY (30) DAYS IN ADVANCE.
THE REHABILITATION PHASES SHALL BE AS FOLLOWS:
YEAR 1: PHASE 1 AND 2
PHASE 1 – WELLS 22, 60, 38, 39
PHASE 2 – WELLS 30, 31, 32, 33
YEAR 2: PHASE 3 AND 4
PHASE 3 – WELLS 25, 26, 27, 29
PHASE 4 – WELLS 21, 23, 24, 59
6. NO MORE AND NO FEWER THAN EIGHT WELLS SHALL BE REHABILITATED PER YEAR.
7. THE CONTRACTOR SHALL SUBMIT A MONTHLY CONSTRUCTION SCHEDULE FOR APPROVAL BY THE OWNER
AND ENGINEER PRIOR TO STARTING ANY WORK.
8. EXACT SEQUENCING SHALL BE COORDINATED WITH THE OWNER BEFORE BEGINNING EACH PHASE.
CAST-IN-PLACE CONCRETE
1. A MINIMUM 28 DAY COMPRESSIVE STRENGTH (f'c) OF 4,500 PSI WAS UTILIZED IN THE DESIGN OF STRUCTURAL
REINFORCED CONCRETE. SEE SPECIFICATIONS FOR CONSTRUCTION STRENGTH REQUIREMENTS.
2. THE LOCATION OF ALL CONSTRUCTION JOINTS AND OTHER TYPES OF JOINTS, OTHER THAN THOSE SPECIFIED OR SHOWN
ON THE PLANS, SHALL BE ACCEPTABLE TO THE ENGINEER PRIOR TO PLACING CONCRETE.
REINFORCING STEEL
1. ALL REINFORCING BAR SHALL BE GRADE 60, DEFORMED, ASTM A615, UNLESS NOTED OTHERWISE.
2. DIMENSIONS TO REINFORCING BARS ARE TO BAR CENTERLINES, UNLESS NOTED OTHERWISE. BAR COVER IS THE CLEAR
DISTANCE BETWEEN THE BAR AND THE CONCRETE SURFACE.
3. NO WELDING OF REINFORCING BARS SHALL BE PERMITTED UNLESS APPROVAL IS OBTAINED FROM THE ENGINEER PRIOR
TO CONSTRUCTION.
4. FOR CONCRETE SLABS THAT HAVE A SLOPING TOP FACE, THE TOP LAYERS OF REINFORCEMENT SHALL BE PLACED ON A
SIMILAR SLOPE SO THAT SPECIFIED COVER IS MAINTAINED.
POST-INSTALLED ANCHORS
1. POST-INSTALLED ANCHORS SHALL INCLUDE ADHESIVE ANCHORS (THREADED RODS, BOLTS OR REINFORCING BARS), EXPANSION ANCHORS, AND UNDERCUT ANCHORS INSTALLED INTO HARDENED CONCRETE OR MASONRY. SEE THE ANCHORAGE IN CONCRETE AND MASONRY SPECIFICATION SECTION FOR ADDITIONAL REQUIREMENTS.
2. POST-INSTALLED ANCHORS SHALL ONLY BE USED WHERE INDICATED ON THE DRAWINGS, CONTRACTOR SHALL OBTAIN APPROVAL FROM ENGINEER PRIOR TO USING POST-INSTALLED ANCHORS FOR MISSING OR MISPLACED CAST-IN-PLACE
ANCHORS.
3. CARE SHALL BE TAKEN TO AVOID CONFLICTS WITH EXISTING REINFORCING STEEL AND OTHER EMBEDDED ITEMS WHEN DRILLING HOLES. REINFORCING BARS SHALL NOT BE DAMAGED DURING DRILLING OR ANCHOR INSTALLATION. HOLES SHALL BE DRILLED AND CLEANED PER THE PRODUCT MANUFACTURER'S INSTRUCTIONS. ANCHORS SHALL BE INSTALLED PER THE PRODUCT MANUFACTURER'S INSTRUCTIONS AT NOT LESS THAN MINIMUM EDGE DISTANCES AND/OR SPACING
INDICATED IN THE MANUFACTURER'S LITERATURE.
4. SUBSTITUTION REQUESTS FOR PRODUCTS OTHER THAN THOSE LISTED IN THE SPECIFICATION OR INDICATED ON THE DRAWINGS SHALL BE SUBMITTED TO ENGINEER FOR REVIEW AND APPROVAL. PRODUCT ISS-ESR EVALUATION REPORTS SHALL BE INCLUDED WITH THE SUBMITTAL PACKAGE. IF REQUESTED, CALCULATIONS PREPARED BY A REGISTERED PROFESSIONAL ENGINEER USING METHODS AND PROCEDURES REQUIRED BY THE BUILDING CODE MAY BE REQUIRED AS
PART OF THE SUBMITTAL PACKAGE.
5. UNLESS NOTED OTHERWISE, THE MINIMUM EMBEDMENT PROVIDED FOR ADHESIVE ANCHORED REINFORCING BARS SHALL
DEVELOP THE FULL TENSILE STRENGTH OF THE BAR.
6. SPECIAL INSPECTION WILL BE PROVIDED FOR ALL POST-INSTALLED ANCHORS.
FD
C :\P
W _W
O R
KI
N
G \B
VW
_A
M
ER
IC
AS
_2 \D
9\
G -0
1.
D
W G
1/
/2
3:
:3
PM
G-01
GENERAL
NOTES
SAA
KMC
MM
MM
APPROVED:
DESIGNED:
DETAILED:
CHECKED:
DATE:
REVISIONS AND RECORD OF ISSUE
OF
PROJECT NO.:
43211/20(SCALE BAR IS 4" AT FULL SCALE)
D
FI
LE
PL
O
TT
ED
Black & Veatch Corporation
CARLTON WELLFIELD
REHABILITATION
JANUARY 2026
100% ISSUED
FOR BID
421334
SARASOTA COUNTY UTILITIES
1001 SARASOTA CENTER
BOULEVARD,
SARASOTA, FL 34240
FLORIDA LAW REQUIRES
EXCAVATORS TO NOTIFY
OWNERS OF UNDERGROUND
FACILITIES NO LESS THAN TWO
(2) DAYS PRIOR TO EXCAVATION
SEK
SEK
THIS DRAWING WAS
ORIGINALLY SIGNED AND
SEALED BY STEVEN KING, A
LICENSED PROFESSIONAL
ENGINEER IN THE STATE OF
FLORIDA, NO. 74954, ON
1/30/2026
SP21
STP23
TP26
TP27
TP30
TP31
TP32
TP33
TP38
STP24
SP25
TP29
TP39
SP22R
2025 Microsoft Corporation 2025 Maxar CNES (2025) Distribution Airbus DSCC C Microsoft Bing
W
EL
L
FI
EL
D
RD
WELL FIELD RD
WATERLINE TRAIL
N M
AB
RY
C
AR
LT
O
N
PK
W Y
STOCKADE TRAIL
S POWER LINE TRAIL
SARASOTA COUNTY CARLTON WTP -
CONTRACTOR REPRESENTATIVE TO
CHECK IN/OUT AT MAIN BUILDING
(SEE NOTE 7)
EXISTING CARLTON WTP
ACCESS GATE - CONTRACTOR
TO CHECK IN WITH CARLTON
WTP OPERATOR FOR
INGRESS AND EGRESS
EXISTING CARLTON WTP
ACCESS GATE - CONTRACTOR
TO CHECK IN WITH CARLTON
WTP OPERATOR FOR
INGRESS AND EGRESS
1000' 500' 0 1000' 2000'
FD
C :\P
W _W
O R
KI
N
G \B
VW
_A
M
ER
IC
AS
_2 \D
9\
G -0
2.
D
W G
1/
/2
2:
:5
PM
G-02
GENERAL
OVERALL SITE MAP AND
GENERAL LEGEND
SAA
KMC
MM
MM
APPROVED:
DESIGNED:
DETAILED:
CHECKED:
DATE:
REVISIONS AND RECORD OF ISSUE
OF
PROJECT NO.:
43211/20(SCALE BAR IS 4" AT FULL SCALE)
D
FI
LE
PL
O
TT
ED
Black & Veatch Corporation
CARLTON WELLFIELD
REHABILITATION
JANUARY 2026
100% ISSUED
FOR BID
421334
SARASOTA COUNTY UTILITIES
1001 SARASOTA CENTER
BOULEVARD,
SARASOTA, FL 34240
SP22R
TP29
TP27
SP25
SP21
STP23
STP24
TP26
TP30
TP31
TP32
TP33
TP38
TP39
1024005.548
1021556.064
1028679.488
1028827.784
1021334.064
1027827.283
1026605.052
1024553.764
1018614.904
1023760.183
1020869.936
1028137.752
1026158.079
1018578.917
1023312.337
1025735.834
LEGEND
PRODUCTION WELL
INGRESS/EGRESS
ACCESS ROAD
550347.266
546920.079
555237.771
557925.496
565073.13
559868.377
561689.213
564164.57
562164.073
544445.225
549565.323
552131.093
550963.423
566388.725
546221.124
547167.052
COORDINATE TABLE
PRODUCTION
WELL NORTHING EASTING
NOTES:
1. THE PROJECT IS LOCATED AT THE T. MABRY
CARLTON WATER TREATMENT PLANT.
1255 N MABRY CARLTON PKWY,
VENICE, FL 34292
2. ROADS SHOWN ARE AVAILABLE FOR
ACCESS TO THE WELLS. CONTRACTOR
SHALL COORDINATE WITH THE OWNER FOR
ACCESS AND DAILY CHECK-INS, AS
REQUIRED BY THE OWNER.
3. CONDITION OF THE EXISTING ACCESS
ROADS SHALL NOT BE WORSENED BY THE
CONTRACTOR'S ACTIVITIES AND SHALL BE
RESTORED SHOULD DAMAGE OCCUR, AS
NOTED BY THE OWNER AND ENGINEER.
4. EXISTING ROAD CONDITIONS ARE UNPAVED.
SECTIONS OF THE ROAD MAY BECOME
FLOODED OR INACCESSIBLE DURING THE
RAINY SEASON. THE CONTRACTOR SHALL
PLAN ACCORDINGLY AND UTILIZE SUITABLE
OFF-ROAD OR HIGH-CLEARANCE VEHICLES
TO ENSURE ACCESS TO THE SITE.
5. CONTRACTOR PARKING SHALL BE LIMITED
TO AVAILABLE LAND ADJACENT TO EACH
WELL WITHOUT OBSTRUCTING TRAFFIC
ACCESS. THE CONTRACTOR IS
RESPONSIBLE FOR RESTORING THE
PROJECT AREA TO IT'S ORIGINAL CONDITION
AND IMPLEMENTING MEASURES TO MINIMIZE
SOIL DISTURBANCE AND EROSION.
6. CONTRACTOR SHALL FOLLOW SECTION
01614 PRODUCT STORAGE AND HANDLING
REQUIREMENTS AND SECTION 01612
PRODUCT DELIVERY REQUIREMENTS FOR
ALL MATERIAL STORAGE. A PERMANENT
LAYDOWN AREA WILL BE PROVIDED NEAR
THE CARTON WATER TREATMENT PLANT,
AND THE CONTRACTOR SHALL COMPLY
WITH ALL SPECIFIED SAFETY AND
PROTECTION MEASURES. TEMPORARY
LAYDOWN AREAS AT PRODUCTION WELLS
SHALL BE LOCATED WITHIN THE EXISTING
CHAIN-LINK FENCE.
7. CONTRACTOR SHALL CHECK IN AND OUT
WITH THE CARLTON WTP OPERATOR UPON
SITE ENTRY AND EXIT.
8. CONTRACTOR’S SUPERINTENDENT SHALL
PROVIDE A DAILY WORK SUMMARY AND
NOTIFY THE WTP OPERATOR IN ADVANCE
OF ANY WELL-RELATED ACTIVITIES,
OUTAGES, ELECTRICAL CONNECTIONS, OR
OTHER OPERATIONAL IMPACTS.
SEK
SEK
THIS DRAWING WAS
ORIGINALLY SIGNED AND
SEALED BY STEVEN KING, A
LICENSED PROFESSIONAL
ENGINEER IN THE STATE OF
EXISTING WELL PHOTOGRAPHIC DETAIL (TYP OF PRODUCTION WELL SP 21
STP 23,STP 24, SP 25, SP 26, TP 27, TP 29, TP 30, TP 31, TP 32, TP 33, TP 38, TP 39, 59, 60)A
EXISTING WELLHEAD PHOTOGRAPHIC DETAIL
(TYP OF PRODUCTION WELL SP22, SP 25, TP 31, TP 39)B
FD
C :\P
W _W
O R
KI
N
G \B
VW
_A
M
ER
IC
AS
_2 \D
5\
C -0
1.
D
W G
1/
/2
2:
:3
PM
C-01
CIVIL
DEMOLITION DETAILS
SAA
KMC
MM
MM
APPROVED:
DESIGNED:
DETAILED:
CHECKED:
DATE:
REVISIONS AND RECORD OF ISSUE
OF
PROJECT NO.:
43211/20(SCALE BAR IS 4" AT FULL SCALE)
D
FI
LE
PL
O
TT
ED
Black & Veatch Corporation
CARLTON WELLFIELD
REHABILITATION
JANUARY 2026
100% ISSUED
FOR BID
421334
SARASOTA COUNTY UTILITIES
1001 SARASOTA CENTER
BOULEVARD,
SARASOTA, FL 34240
NOTES
SHEET KEYNOTES
1. CONTRACTOR TO COORDINATE WITH OWNER AND EOR
FOR DEMOLITION SCHEDULE.
2. CONTRACTOR TO BE AWARE THAT THERE ARE VARIOUS
WELLHEAD SIZES AND WELL DISCHARGE PIPING SIZES
AND APPURTENANCES. SEE TABLE 2 IN THE TECHNICAL
SPECIFICATIONS FOR SITE SPECIFIC INFORMATION.
3. WELL SITE LAYOUTS AND PIPING CONFIGURATIONS VARY
ACROSS THE EXISTING WELL SITES. THE CONTRACTOR
SHALL PERFORM A SITE VISIT PRIOR TO BIDDING AND
ACKNOWLEDGE ALL VARYING SITE CONDITIONS.
4. EXISTING SUBMERSIBLE PUMPS SHALL BE CAREFULLY
REMOVED, SALVAGED, AND STORED IN OWNER'S WTP.
WELL PUMP REMOVAL AND STORAGE SHALL BE
COORDINATED IN ADVANCE BY THE CONTRACTOR AND
OWNER.
5. EXISTING CONDUCTIVITY METERS SHALL BE SALVAGED
AFTER THE NEW PIPING HAS BEEN INSTALLED.
6. DEMOLITION OF THE EXISTING BURIED WATER MAINS
SHALL NOT STOP AT A JOINT, IF POSSIBLE. THE EXISTING
PIPING SHALL BE CUT TO MAKE A PLAIN END,
APPROXIMATELY 5 FEET OR MORE FROM AN EXISTING
JOINT, TO ALLOW ROOM FOR THE RESTRAINED COUPLING
ADAPTERS TO BE INSTALLED.'
7. LOCATIONS, DEPTHS, SIZE, AND MATERIAL OF EXISTING
UNDERGROUND UTILITIES ARE APPROXIMATE AND ARE
BASED ON THE BEST AVAILABLE INFORMATION.
CONTRACTOR SHALL FIELD-VERIFY ALL LOCATIONS,
DEPTHS, SIZE, AND MATERIAL BEFORE ORDERING
MATERIALS AND BEGINNING WORK.
8. WELL CASING SHALL REMAIN SEALED AT ALL TIMES
EXCEPT WHEN THE WELL PUMP IS BEING REMOVED OR
INSTALLED.”
9. CONTRACTOR SHALL VERIFY WITH THE OWNER AND RPR
PRIOR TO BEGINNING DEMOLITION FOR ALL PHASES, IN
CASE A PUMP/MOTOR IS TO BE SALVAGED AND REUSED.
THERE IS A CHANCE NOT ALL WELLS AND PUMPS WILL BE
REPLACED. CONTRACTOR TO VERIFY.
1. DEMOLISH EXISTING PIPING AND VALVES AT ALL 16 WELLS.
THIS DEMO WORK INCLUDES ALL ABOVE-GRADE PIPING
AND VALVES AND APPURTENANCES AT EACH WELL, AS
WELL AS BELOW-GRADE PIPING UP TO THE FIRST BURIED
FITTING (UP TO THE CONNECTION POINT TO THE EXISTING
RAW WATER LATERAL) (SEE MECHANICAL DWG).
2. DEMOLISH EXISTING WELLHEAD. WELL SHALL REMAIN
SECURE AT ALL TIME TO PREVENT ARTESIAN CONDITIONS.
3. DEMOLISH EXISTING PIPE SUPPORTS. AFTER NEW PIPE
SUPPORTS ARE INSTALLED, REPAIR SLAB TO
PRE-CONSTRUCTION CONDITIONS OR BETTER
4. EXISTING POWER WIRES, LIGHT POLES, POWER PANELS,
INSTRUMENTATION PANELS, FIBER TERMINATION
CONNECTIONS TO REMAIN AND BE PROTECTED IN-PLACE.
5. EXISTING CONCRETE PEDESTAL TO BE DEMOLISHED.
6. PROTECT WELL SITE FENCING IN PLACE TO THE MAXIMUM
PRACTICAL EXTENTS. (SEE GENERAL NOTE 19).
SEK
SEK
THIS DRAWING WAS
ORIGINALLY SIGNED AND
SEALED BY STEVEN KING, A
LICENSED PROFESSIONAL
ENGINEER IN THE STATE OF
PROPOSED SITING
FOR RPR TRAILER
(SEE NOTE 1)
EXISTING POTABLE
WATER TIE IN POINT
FOR RPR TRAILER
(SEE NOTE 1)
EXISTING
TRANSFORMER POWER
FEED FOR RPR TRAILER
(SEE NOTE 3 AND 4)
PERMANENT
LAYDOWN AREA
(SEE NOTE 5)
COVERED
PERMANENT
LAYDOWN AREA
(SEE NOTE 5 AND 6)
PROPOSED
ADDITIONAL
CONTRACTOR
AND RPR
PARKING (SEE
NOTE 1)
T. MABRY CARLTON
WATER TREATMENT
FACILITY
FD
C :\P
W _W
O R
KI
N
G \B
VW
_A
M
ER
IC
AS
_2 \D
5\
C -0
2.
D
W G
1/
/2
2:
:1
PM
C-02
CIVIL
PERMANENT LAYDOWN
AREA DETAIL
SAA
HK
MM
MM
GENERAL NOTES:
1. CONTRACTOR SHALL COORDINATE TRAILER PLACEMENT
WITH SARASOTA COUNTY PRIOR TO MOBILIZATION.
CONTRACTOR IS ADVISED THAT A CONCURRENT PROJECT
WILL BE ACTIVE ON SITE; THEREFORE, ALL MOBILIZATION
ACTIVITIES, MATERIAL STORAGE, AND PARKING
ARRANGEMENTS MUST BE COORDINATED IN ADVANCE
WITH THE OWNER AND OTHER CONTRACTORS.
2. CONTRACTOR SHALL CONNECT TO POTABLE WATER
PIPING USING A TEMPORARY NSF-61 COMPLIANT HOSE
AND PROVIDE ALL NECESSARY PIPING, FITTINGS, AND
COMPONENTS TO SUPPLY WATER TO THE TRAILER.
CONTRACTOR SHALL INSTALL A FLOW METER AND
RECORD WEEKLY WATER USAGE, REPORTING TOTALS TO
THE OWNER.
3. CONTRACTOR SHALL PROVIDE A TEMPORARY POWER
SUPPLY AND CONNECT TO THE EXISTING TRANSFORMER.
ALL TIE-INS MUST BE COORDINATED WITH THE OWNER
AND POWER PROVIDER IN ADVANCE TO PREVENT
OPERATIONAL DISRUPTIONS.
4. CONTRACTOR SHALL NOTIFY THE OWNER AT LEAST 14
DAYS PRIOR AND SUBMIT A DETAILED ELECTRICAL TIE-IN
PLAN FOR REVIEW AND APPROVAL BEFORE SCHEDULING
ANY WORK. TEMPORARY ELECTRICAL MINING CABLE
SHALL BE ROUTED IN COMPLIANCE WITH NEC SAFETY
STANDARDS, CLEARLY IDENTIFIED WITH MARKERS, AND
PROTECTED BY BARRIERS.
5. CONTRACTOR SHALL FOLLOW SECTION 01614 PRODUCT
STORAGE AND HANDLING REQUIREMENTS AND SECTION
01612 PRODUCT DELIVERY REQUIREMENTS FOR ALL
MATERIAL STORAGE.
6. CONTRACTOR SHALL COORDINATE THE LOCATION OF THE
COVERED PERMANENT LAYDOWN AREA WITH CARLTON
WTP OPERATIONS IN ADVANCE TO PREVENT ANY
DISRUPTION TO PLANT OPERATIONS. CONTRACTOR SHALL
SUBMIT A STORAGE PLAN PRIOR TO IMPLEMENTATION,
INCLUDING FOOTPRINT, DURATION, AND PROTECTIVE
MEASURES FOR SPECIALIZED EQUIPMENT.
7. CONTRACTOR SHALL AVOID DISRUPTION TO WTP
OPERATIONS DURING INGRESS, EGRESS, AND MATERIAL
TRANSPORT WITHIN THE WTP PERIMETER.
8. ACTIVITIES SHALL BE LIMITED TO EXISTING ROADWAYS
AND LIMITED AREAS INCLUDED IN THIS SHEET.
CONTRACTOR SHALL DOCUMENT EXISTING SITE
CONDITIONS PRIOR TO MOBILIZATION AND RESTORE ALL
UTILIZED AREAS TO PRE-DISTURBED CONDITIONS,
INCLUDING SODDING, STABILIZATION, AND OTHER
NECESSARY MEASURES.
APPROVED:
DESIGNED:
DETAILED:
CHECKED:
DATE:
REVISIONS AND RECORD OF ISSUE
OF
PROJECT NO.:
43211/20(SCALE BAR IS 4" AT FULL SCALE)
D
FI
LE
PL
O
TT
ED
Black & Veatch Corporation
CARLTON WELLFIELD
REHABILITATION
JANUARY 2026
100% ISSUED
FOR BID
421334
SARASOTA COUNTY UTILITIES
1001 SARASOTA CENTER
BOULEVARD,
SARASOTA, FL 34240
LEGEND
PERMANENT LAYDOWN AREA
COVERED PERMANENT LAYDOWN AREA
PROPOSED SITING FOR RPR TRAILER
PROPOSED ADDITIONAL PARKING FOR
CONTRACTOR AND RPR
SEK
SEK
THIS DRAWING WAS
ORIGINALLY SIGNED AND
SEALED BY STEVEN KING, A
LICENSED PROFESSIONAL
ENGINEER IN THE STATE OF
TABLE A PRODUCTION WELL EXISTING PIPE SIZING TABLE
NOTE:
SET VALVE BOX SO AS TO RESERVE 1/2 OF
THE ADJUSTMENT LENGTH FOR FUTURE USE.
2-1" DIA,
PICKHOLES
ADJUSTABLE VALVE BOX AND COVER DETAIL
8-1/2"
7-1/2"
6-1/8"
2"
-3
/4 " M
IN
2- 5/
8" 2"
1/
3/8"
3/8"
5-11/16"
8-1/2"
10-3/4"
VA
R
IE
S
5- 1/
2"
5-1/4"
1-5/8"
1/16"
7/32"
1/ 2"
1- 5/
8"
1/ 2"
7-3/8"
5-3/4" 3/8" 3/8"
3/8"
3"2" 1"
3/ 8"
NOTE:
1/8" BRASS PLATE WITH ANCHORS IN
SURFACE OF CONCRETE PROVIDE MINIMUM
OF 4 BRASS ANCHORS, MINIMUM OF 2" LONG.
CHAMFER VALVE
PAD TOP EDGES
BRASS I.D. PLATE
2500 PSI CONCRETE PAD
WITH #10-6"x6" WWF
VALVE PAD DETAILS
24"
12"
4" 1"
VALVE BOX
(SEE DETAIL)
NOTES:
1. FITTINGS SHALL BE RESTRAINED JOINTS UNLESS OTHERWISE INDICATED.
2. INSTALL FULL LENGTH JOINTS WITH TOTAL LENGTH EQUAL TO OR GREATER THAN
SHOWN IN THE TABLE.
3. WHERE TWO OR MORE FITTINGS ARE TOGETHER, USE FITTING WHICH YIELDS
GREATEST LENGTH OF RESTRAINED PIPE.
4. ALL LINE VALVES AND THROUGH RUN OF TEES SHALL BE RESTRAINED.
5. WHERE CONNECTIONS TO EXISTING PIPE IS MADE, CONTRACTOR SHALL CONFIRM
THE EXITING PIPE IS RESTRAINED PER THE ABOVE TABLE, AND IF NOT SHALL
ADD RESTRAINING TO THE EXISTING PIPE PER THE ABOVE TABLE.
6. BASED ON RECORD DRAWINGS, SOME EXISTING FITTINGS ARE SHOWN TO HAVE
THRUST BLOCKS. THRUST BLOCKS SHOULD NOT BE RELIED UPON WHEN DETERMINING
MINIMUM LENGTH TO BE RESTRAINED.
PLUG OR BRANCH
OF TEE
TABLE A PRODUCTION WELL EXISTING PIPE SIZING
FD
C :\P
W _W
O R
KI
N
G \B
VW
_A
M
ER
IC
AS
_2 \D
5\
C -0
3.
D
W G
1/
/2
3:
:0
PM
C-03
CIVIL
CIVIL AND PIPING DETAILS
SAA
HK
MM
MM
NOTES
1. TABLE A - EXISTING PRODUCTION WELL AND RWTM
LATERAL PIPE SHALL BE USED FOR REFERENCE ONLY.
LOCATIONS, DEPTHS, SIZE AND MATERIAL OF EXISTING
UNDERGROUND UTILITIES ARE APPROXIMATE AND IS
BASED ON THE BEST AVAILABLE INFORMATION,
CONTRACTOR SHALL FIELD VERIFY ALL LOCATIONS,
DEPTHS, SIZE AND MATERIAL BEFORE ORDERING
MATERIALS AND BEGINNING WORK.
APPROVED:
DESIGNED:
DETAILED:
CHECKED:
DATE:
REVISIONS AND RECORD OF ISSUE
OF
PROJECT NO.:
43211/20(SCALE BAR IS 4" AT FULL SCALE)
D
FI
LE
PL
O
TT
ED
Black & Veatch Corporation
CARLTON WELLFIELD
REHABILITATION
JANUARY 2026
100% ISSUED
FOR BID
421334
SARASOTA COUNTY UTILITIES
1001 SARASOTA CENTER
BOULEVARD,
SARASOTA, FL 34240
SEK
SEK
THIS DRAWING WAS
ORIGINALLY SIGNED AND
SEALED BY STEVEN KING, A
LICENSED PROFESSIONAL
ENGINEER IN THE STATE OF
FD
C :\P
W _W
O R
KI
N
G \B
VW
_A
M
ER
IC
AS
_2 \D
5\
C -0
4.
D
W G
1/
/2
2:
:5
PM
C-04
CIVIL
EROSION CONTROL
DETAILS
SAA
CRS
MM
MM
APPROVED:
DESIGNED:
DETAILED:
CHECKED:
DATE:
REVISIONS AND RECORD OF ISSUE
OF
PROJECT NO.:
43211/20(SCALE BAR IS 4" AT FULL SCALE)
D
FI
LE
PL
O
TT
ED
Black & Veatch Corporation
CARLTON WELLFIELD
REHABILITATION
JANUARY 2026
100% ISSUED
FOR BID
421334
SARASOTA COUNTY UTILITIES
1001 SARASOTA CENTER
BOULEVARD,
SARASOTA, FL 34240
SEK
SEK
THIS DRAWING WAS
ORIGINALLY SIGNED AND
SEALED BY STEVEN KING, A
LICENSED PROFESSIONAL
ENGINEER IN THE STATE OF
WELLHEAD AND PIPING SECTION
1/4" = 1'-0"
16" WELLHEAD PLAN DETAIL 12" WELLHEAD PLAN DETAIL
16" WELLHEAD SECTION DETAIL 12" WELLHEAD SECTION DETAIL
3/4"=1'-0"
6"12" 0 1' 2' 3'
NO SCALE
APPROVED:
DESIGNED:
DETAILED:
CHECKED:
DATE:
REVISIONS AND RECORD OF ISSUE
OF
PROJECT NO.:
43211/20(SCALE BAR IS 4" AT FULL SCALE)
D
FI
LE
PL
O
TT
ED
Black & Veatch Corporation
CARLTON WELLFIELD
REHABILITATION
JANUARY 2026
100% ISSUED
FOR BID
421334
SARASOTA COUNTY UTILITIES
1001 SARASOTA CENTER
BOULEVARD,
SARASOTA, FL 34240
FD
MECHANICAL
TYPICAL SECTION AND
PRODUCTION WELL
DETAILS
SAA
KMC
MM
MM
NOTES
SHEET KEYNOTES
3/4" = 1'-0"
3" = 1'-0"
SEK
SEK
THIS DRAWING WAS
ORIGINALLY SIGNED AND
SEALED BY STEVEN KING, A
LICENSED PROFESSIONAL
ENGINEER IN THE STATE OF
1'-01 2"
1'-5"
DIA. (FIELD VERIFY)
1'-01 2"
1' -0
1 2"
1' -5
D
IA
FI
EL
D V
ER
IF
Y)
1' -0
1 2"
0' -2
" C
LR
TY
P.
3'-6"
3' -6
" 2
0'-2"
TYP
#5@12" O.C. E.F.
#3@6" O.C. U-BARS E.F.
NEW CONC. PEDESTAL, TYP.
STD. LAP TYP.
EXISTING CASING
ACCESS PORT
NEW CONCRETE PEDESTAL
ROUGHEN SURFACE TO
1/4'' AMPLITUDE (TYP)
1'-0" MIN
FIELD
VERIFY
EXISTING FLANGE
2" M
IN
EPOXY DOWELS (TYP)
6" E
M
BE
D M
IN
EXISTING CONCRETE
SLAB ON GRADE
1/2" EXP JT MTL
WITH SEALANT AND
BACKER ROD ALL
AROUND (TYP)
1'-0"
1'-0"
DIA. (FIELD VERIFY)
1'-0"
1' -0
1' -0
D
IA
FI
EL
D V
ER
IF
Y)
1' -0
0' -2
" C
LR
TY
P.
3'-0"
3' -0
" 2
0'-2"
TYP
#5@12" O.C. E.F.
#3@6" O.C. U-BARS E.F.
NEW CONC. PEDESTAL, TYP.
STD. LAP TYP. EXISTING CASING
BUILD UP OR REINFORCE
PIPE AT SUPPORT LOCATIONS
AS NEEDED
1/2" DIAMETER THREADED
ROD ADHESIVE ANCHORS
1" GROUT
3" DIAMETER SCHEDULE 40
STEEL PIPE
1/2" DIAMETER U-BOLT
SEE PLANS FOR PIPE SIZE
MATERIAL AND ELEVATION
5" WIDE PLATE
3/8" THICK FOR ALL AIR PIPE
1/2" THICK FOR LIQUID PIPE
UP TO 20" DIAMETER
1/2" PLATE
TY
P
AS
R
EQ
U
IR
ED
0' -8
SQ
0' -1
/2
TY
P
0' -2
/2
TY
P 0'
-2
/2
TY
P
0' -1
/2
TY
P
0'-5 1/2" MINIMUM FROM EDGE
OF CONCRETE TYPICAL
1/4
1/4
1/
2" M
IN
NOTE:
ALL STEEL MATERIALS SHALL BE HOT-DIP GALVANIZED FOR
EXTERIOR LOCATIONS. VENT HOLES FOR GALVANIZING SHALL
BE THE MINIMUM SIZE NECESSARY. HOLES SHALL BE LOCATED
IN THE BOTTOM BASEPLATE AND ALSO LOCATED IN THE TOP OF
THE PIPE, ADJACENT TO THE CURVED PLATE.
CONCRETE COVER FOR REINFORCEMENT
BEAMS & COLUMNS WALLS & SLABS
LENGTH OF LAPPED SPLICES
FOR REINFORCEMENT (INCHES)
**TOP BARS OTHERS **TOP BARS OTHERS
LOCATION SPECIFIED COVER
BAR
SIZE
UNLESS NOTED OTHERWISE ON THE DRAWINGS
4255#7
122#11
#8
#9
#10
#3 16
#4
#5
#6
#7
#11
#8
#9
#10
#3
#4
#6
#5
* LAP SPLICE LENGTH FOR BARS OF DIFFERENT SIZES SHALL BE THE
GREATER OF THE SMALL BAR LAP LENGTH OR 0.75x THE LARGER BAR
LAP LENGTH.
** TOP BARS ARE HORIZONTAL BARS SO PLACED THAT MORE THAN 12" OF
CONCRETE IS CAST IN THE MEMBER BELOW THE BAR. HORIZONTAL BARS
IN WALLS ARE TO BE PROVIDED WITH LAP LENGTHS AS REQUIRED FOR
TOP BARS. VERTICAL BARS MAY BE CONSIDERED AS OTHER BARS.
UNFORMED SURFACES ADJACENT TO EXCAVATION................... 3"
SURFACES INSIDE OZONE CONTACTOR STRUCTURES EXPOSED
TO OZONE IN WATER OR AIR.......................................................... 3"
FORMED SURFACES THAT ARE SUBMERGED, AND FORMED
OR TOP SURFACES EXPOSED TO WEATHER, SATURATED
AIR, OR EARTH................,................................................................. 2"
OTHER LOCATIONS:
SLABS..............................................................................................1 1/2"
#5 AND LARGER.......................................................................... 1 1/2"
#4 AND SMALLER......................................................................... 1"
NOTES:
1. COVER IS MEASURED TO NEAREST BAR, STIRRUP, TIE, OR
SPIRAL, AS APPLICABLE.
2. TOLERANCES FOR CONCRETE COVER AND THE FABRICATION
AND PLACING OF REINFORCEMENT SHALL CONFORM TO ACI 117.
TOP SURFACES OF SLABS THAT ARE SUBMERGED.................... 3"
UNLESS NOTED OTHERWISE ON THE DRAWINGS
BAR
SIZE
EXISTING CONCRETE
TO BE DEMOLISHED
CONCRETE REPAIR
MATERIAL
EXISTING CONCRETE
FLOOR OR WALL
N O
TE
DEMOLISH EXISTING CONCRETE WITH
CHIPPING HAMMER (30 LB MAX) OR
OTHER APPROVED LIGHT CONCRETE
DEMOLITION TOOLS. PERFORM THIS
OPERATION AFTER EQUIPMENT BASE
REMOVAL. SEE NOTE 2.
1.
2.
NOTES:
DEPTH OF CONCRETE DEMOLITION SHALL BE THE LESSER OF 2" OR THE
DEPTH OF CONCRETE COVER OVER THE EXISTING REINFORCEMENT. DO NOT
DAMAGE EXISTING REINFORCEMENT PARALLEL TO REPAIRED SURFACE.
CARE SHALL BE TAKEN TO AVOID DAMAGING CONCRETE SUBSTRATE DURING
CHIPPING OPERATION.
RECTANGULAR SAW CUT BEYOND
PERIMETER OF CONCRETE TO BE
DEMOLISHED, SEE SPECIFICATION
FOR DEPTH REQUIREMENTS
DEMOLISH EXISTING
REINFORCEMENT TO SAME
LEVEL AS DEMOLISHED
CONCRETE
2" MIN
(TYP)
FD
C :\P
W _W
O R
KI
N
G \B
VW
_A
M
ER
IC
AS
_2 \D
4\
S-
.D W
G 1/
/2
2:
:5
PM
S-01
STRUCTURAL
DETAILS
SAA
CRS
MM
MM
NOTES
1. CONTRACTOR TO DESIGN EQUIPMENT ANCHORAGE.
2. FINAL DIMENSIONS AND LOCATION OF CONCRETE PUMP
PAD TO BE COORDINATED WITH EQUIPMENT SUBMITTALS.
3. CONTRACTOR TO COORDINATE ALL OPENING SIZES AND
LOCATIONS WITH CIVIL AND MECHANICAL DRAWINGS.
4. CONTRACTOR TO COORDINATE ALL EQUIPMENT AND
PUMP LOCATIONS WITH CIVIL AND MECHANICAL
DRAWINGS.
APPROVED:
DESIGNED:
DETAILED:
CHECKED:
DATE:
REVISIONS AND RECORD OF ISSUE
OF
PROJECT NO.:
43211/20(SCALE BAR IS 4" AT FULL SCALE)
D
FI
LE
PL
O
TT
ED
Black & Veatch Corporation
CARLTON WELLFIELD
REHABILITATION
JANUARY 2026
100% ISSUED
FOR BID
421334
SARASOTA COUNTY UTILITIES
1001 SARASOTA CENTER
BOULEVARD,
SARASOTA, FL 34240
16" CASING PIPE PEDESTALA
- 3/4" = 1'-0"
SECTION2
- 1/2" = 1'-0"
12" CASING PIPE PEDESTALB
- 3/4" = 1'-0"
3 INCH DIAMETER STEEL COLUMN PIPE SUPPORTC
- 1" = 1'-0"
4"1
2" 03 4"
GENERAL
1. THE APPLICABLE BUILDING CODE IS INDICATED ON THE LOADING CRITERIA DRAWING.
2. THE REQUIREMENTS INDICATED ON THIS SHEET ARE INTENDED AS A BASIC SUMMARY OF THE MATERIAL AND CONSTRUCTION REQUIREMENTS FOR THE PROJECT. ADDITIONAL , MORE STRINGENT REQUIREMENTS ARE GIVEN IN THE PROJECT DETAIL DRAWINGS AND SPECIFICATIONS.
3. ALL STRUCTURAL RELATED SHOP DRAWINGS SHALL BE REVIEWED BY THE ENGINEER PRIOR TO CONSTRUCTION.
4. STRUCTURES MAY BE BUOYANT WHEN EMPTY DURING CONSTRUCTION. CONTRACTOR SHALL PROTECT STRUCTURES AGAINST FLOTATION UNTIL
CONSTRUCTION IS COMPLETE.
5. STRUCTURES MAY BE UNSTABLE UNTIL THEY ARE CONSTRUCTED IN THEIR ENTIRETY. CONTRACTOR IS RESPONSIBLE FOR DESIGNING TEMPORARY STRUCTURAL SUPPORTS TO RESIST WIND LOADS, CONSTRUCTION LOADS, AND ANY OTHER TEMPORARY CONDITIONS THAT MAY OCCUR DURING CONSTRUCTION, IN ORDER TO MAINTAIN STABILITY OF THE CONSTRUCTION WORK, ANCHORS FOR CONTRACTORS TEMPORARY SUPPORT SYSTEMS THAT ATTACH TO CONCRETE OR MASONRY SHALL BE LOCATED TO AVOID DAMAGING EMBEDDED REINFORCEMENT OR
UTILITIES
CAST-IN-PLACE CONCRETE
1. A MINIMUM 28 DAY COMPRESSIVE STRENGTH (f'c) OF 4,500 PSI WAS UTILIZED IN THE DESIGN OF STRUCTURAL REINFORCED CONCRETE. SEE
SPECIFICATIONS FOR CONSTRUCTION STRENGTH REQUIREMENTS.
2. THE LOCATION OF ALL CONSTRUCTION JOINTS AND OTHER TYPES OF JOINTS, OTHER THAN THOSE SPECIFIED OR SHOWN ON THE PLANS, SHALL
BE ACCEPTABLE TO THE ENGINEER PRIOR TO PLACING CONCRETE.
CONCRETE FLOOR OR WALL REPAIR FOLLOWING DEMOLITIOND
- 3" = 1'- 0
REINFORCING STEEL
1. ALL REINFORCING BAR SHALL BE GRADE 60, DEFORMED,
ASTM A615, UNLESS NOTED OTHERWISE.
2. DIMENSIONS TO REINFORCING BARS ARE TO BAR
CENTERLINES, UNLESS NOTED OTHERWISE. BAR COVER IS
THE CLEAR DISTANCE BETWEEN THE BAR AND THE
CONCRETE SURFACE.
3. NO WELDING OF REINFORCING BARS SHALL BE PERMITTED
UNLESS APPROVAL IS OBTAINED FROM THE ENGINEER
PRIOR TO CONSTRUCTION.
4. FOR CONCRETE SLABS THAT HAVE A SLOPING TOP FACE,
THE TOP LAYERS OF REINFORCEMENT SHALL BE PLACED
ON A SIMILAR SLOPE SO THAT SPECIFIED COVER IS
MAINTAINED.
POST-INSTALLED ANCHORS
1. POST-INSTALLED ANCHORS SHALL INCLUDE ADHESIVE
ANCHORS (THREADED RODS, BOLTS OR REINFORCING
BARS), EXPANSION ANCHORS, AND UNDERCUT ANCHORS
INSTALLED INTO HARDENED CONCRETE OR MASONRY. SEE
THE ANCHORAGE IN CONCRETE AND MASONRY
SPECIFICATION SECTION FOR ADDITIONAL REQUIREMENTS.
2. POST-INSTALLED ANCHORS SHALL ONLY BE USED WHERE
INDICATED ON THE DRAWINGS, CONTRACTOR SHALL
OBTAIN APPROVAL FROM ENGINEER PRIOR TO USING
POST-INSTALLED ANCHORS FOR MISSING OR MISPLACED
CAST-IN-PLACE ANCHORS.
3. CARE SHALL BE TAKEN TO AVOID CONFLICTS WITH
EXISTING REINFORCING STEEL AND OTHER EMBEDDED
ITEMS WHEN DRILLING HOLES. REINFORCING BARS SHALL
NOT BE DAMAGED DURING DRILLING OR ANCHOR
INSTALLATION. HOLES SHALL BE DRILLED AND CLEANED
PER THE PRODUCT MANUFACTURER'S INSTRUCTIONS.
ANCHORS SHALL BE INSTALLED PER THE PRODUCT
MANUFACTURER'S INSTRUCTIONS AT NOT LESS THAN
MINIMUM EDGE DISTANCES AND/OR SPACING INDICATED IN
THE MANUFACTURER'S LITERATURE.
4. SUBSTITUTION REQUESTS FOR PRODUCTS OTHER THAN
THOSE LISTED IN THE SPECIFICATION OR INDICATED ON
THE DRAWINGS SHALL BE SUBMITTED TO ENGINEER FOR
REVIEW AND APPROVAL. PRODUCT ISS-ESR EVALUATION
REPORTS SHALL BE INCLUDED WITH THE SUBMITTAL
PACKAGE. IF REQUESTED, CALCULATIONS PREPARED BY A
REGISTERED PROFESSIONAL ENGINEER USING METHODS
AND PROCEDURES REQUIRED BY THE BUILDING CODE MAY
BE REQUIRED AS PART OF THE SUBMITTAL PACKAGE.
5. UNLESS NOTED OTHERWISE, THE MINIMUM EMBEDMENT
PROVIDED FOR ADHESIVE ANCHORED REINFORCING BARS
SHALL DEVELOP THE FULL TENSILE STRENGTH OF THE
BAR.
6. SPECIAL INSPECTION WILL BE PROVIDED FOR ALL
POST-INSTALLED ANCHORS.
SEK
SEK
THIS DRAWING WAS
ORIGINALLY SIGNED AND
SEALED BY STEVEN KING, A
LICENSED PROFESSIONAL
ENGINEER IN THE STATE OF
L L
MEANINGS OF IDENTIFICATION LETTERS
INSTRUMENT AND I/O ABBREVIATIONS
I
PIPELINE MATERIAL CODE ABBREVIATIONS
pH
CON
LOR LOCAL-OFF-REMOTE
FI FLOW DIGITAL INDICATOR (LED OR SCREEN)
POWER FAILURE ALARM
LEVEL INDICATOR (LED OR SCREEN)
PRESSURE INDICATOR (LED OR SCREEN)
SPEED INDICATION (LED OR SCREEN)
SPEED CONTROL
RUN COMMAND
STOP COMMAND
GENERAL ALARM EVENT
EVENT INDICATION (LED OR SCREEN)
RUNNING INDICATION
JA
LI
PI
SI
SC
UCR
UCS
YA
YI
YIR
AUTO/MANUALUC
M
RW RAW WATER
FD
421344
INSTRUMENTATION
I&C - LEGEND &
ABBREVIATIONS
KRW
AWR
APPROVED:
DESIGNED:
DETAILED:
CHECKED:
DATE:
REVISIONS AND RECORD OF ISSUE
OF
PROJECT NO.:
43211/20(SCALE BAR IS 4" AT FULL SCALE)
D
FI
LE
PL
O
TT
ED
Black & Veatch Corporation
CARLTON WELLFIELD
REHABILITATION
JANUARY 2026
100% ISSUED
FOR BID
SARASOTA COUNTY UTILITIES
1001 SARASOTA CENTER
BOULEVARD
SARASOTA, FL 34240
THIS DRAWING WAS
ORIGINALLY SIGNED AND
SEALED BY JEFFREY S. MILLER,
A LICENSED PROFESSIONAL
ENGINEER IN THE STATE OF
FLORIDA, NO. 96128, ON
PL
C
-X X
SC
AD
A H
M I
PL
C
-X X
SC
AD
A H
M I
HS
XXB
LOR
HS
XXA
START
HMS
XXB
STOP
HMS
XXC
RESET
SIC
XX
SPEED
RUN
YLR
XX
FAIL
YAL
XX
ZS
XX
HS
XXA
BYPASS
LI
XX
LEVEL
DRAWDOWN
LI
XX
LEVEL
DRAWDOWN
UC
XX
MANUAL
AUTO/
UCR
XX
CMD
RUN
UCR
XX
CMD
RUN
UCS
XX
CMD
STOP
UCS
XX
CMD
STOP
YA
XXG
FAULT
DRIVE
YA
XXG
FAULT
DRIVE
YI
XXA
REMOTE
IN
YI
XXA
REMOTE
IN
YI
XXB
LOCAL
IN
YI
XXB
LOCAL
IN
YI
XXC
AFD
ON
YI
XXC
AFD
ON
YI
XXD
BYPASS
ON
YI
XXD
BYPASS
ON
YA
XXB
OVERLOAD
MOTOR
YA
XXB
OVERLOAD
MOTOR
SI
XXA
INDICATION
SPEED
SI
XXA
INDICATION
SPEED
SC
XX
CMD
SPEED
SC
XX
CMD
SPEED
YA
XXE
DETECTED
INTRUSION
YA
XXE
DETECTED
INTRUSION
PI
XX
PRESSURE
DISCHARGE
PI
XX
PRESSURE
DISCHARGE
FI
XX
FLOW
DISCHARGE
FI
XX
FLOW
DISCHARGE
JA
XXD
LOSS
PHASE
JA
XXD
LOSS
PHASE
YIR
XX
RUNNING
AFD
YIR
XX
RUNNING
AFD
I
AFD-XX
LE/LT
XX
PG
XX
PIT
XX
VLV-XX
FE
XX
FIT
XX
ZS
XXB
AE
XX
AI
XX
CONDUCTIVITY
DISCHARGE
AI
XX
CONDUCTIVITY
DISCHARGE
VLV-XXVLV-XX
WELL CASING
NOTE 2
FLOW TRANSMITTER
MOUNTED REMOTELY
ON ELECTRICAL RACK
AIT
XX
COND
PLC-XX
NOTE 4
VLV-XX
VLV-XX
SARASOTA COUNTY CARLTON WELL-FIELD
WELL #/ID PUMP ID PIPE SIZE AFD ID PLC PANEL ID F-O PANEL ID LE/LIT TAG PG/PIT TAG FE/FIT TAG AE/AIT TAG
SP21 (DID 1) p- -RW-DIP AFD- PLC- FO- LE/LIT - PG/PIT - FE/FIT- AE/AIT -
STP23 (DID 3) p- -RW-DIP AFD- PLC- FO- LE/LIT - PG/PIT - FE/FIT- AE/AIT -
STP24 (DID 4) p- -RW-DIP AFD- PLC- FO- LE/LIT - PG/PIT - FE/FIT- AE/AIT -
SP22R (DID 57) p- -RW-DIP AFD- PLC- FO- LE/LIT - PG/PIT - FE/FIT- AE/AIT -
SP25 (DID 5) p- -RW-DIP AFD- PLC- FO- LE/LIT - PG/PIT - FE/FIT- AE/AIT -
TP26 (DID 6) p- -RW-DIP AFD- PLC- FO- LE/LIT - PG/PIT - FE/FIT- AE/AIT -
TP27 (DID 7) p- -RW-DIP AFD- PLC- FO- LE/LIT - PG/PIT - FE/FIT- AE/AIT -
TP29 (DID 8) p- -RW-DIP AFD- PLC- FO- LE/LIT - PG/PIT - FE/FIT- AE/AIT -
TP30 (DID 9) p- -RW-DIP AFD- PLC- FO- LE/LIT - PG/PIT - FE/FIT- AE/AIT -
TP31 (DID 10) p- -RW-DIP AFD- PLC- FO- LE/LIT - PG/PIT - FE/FIT- AE/AIT -
TP32 (DID 11) p- -RW-DIP AFD- PLC- FO- LE/LIT - PG/PIT - FE/FIT- AE/AIT -
TP33 (DID 12) p- -RW-DIP AFD- PLC- FO- LE/LIT - PG/PIT - FE/FIT- AE/AIT -
TP38 (DID 13) p- -RW-DIP AFD- PLC- FO- LE/LIT - PG/PIT - FE/FIT- AE/AIT -
TP39 (DID 14) p- -RW-DIP AFD- PLC- FO- LE/LIT - PG/PIT - FE/FIT- AE/AIT -
59 (DID 59) p- -RW-DIP AFD- PLC- FO- LE/LIT - PG/PIT - FE/FIT- AE/AIT -
60 (DID 60) p- -RW-DIP AFD- PLC- FO- LE/LIT - PG/PIT - FE/FIT- AE/AIT -
120VAC
FD
C :\U
SE
R
S\
SU
D
2\
AP
PD
AT
A\
LO
C
AL
\A
U
TO
D
ES
K\
AU
TO
C
AD
P
LA
N
T 3D
\C O
LL
AB
O R
AT
IO
N C
AC
H
E\
SY
ST
EM
W
ID
E W
EL
LF
IE
LD
A
SS
ES
SM
EN
T\
PI
D
D W
G \I-
.D
W G
1/
/2
6:
:3
AM
421344
I-02
INSTRUMENTATION
WELL FIELD TYPICAL P&ID
KRW
AWR
APPROVED:
DESIGNED:
DETAILED:
CHECKED:
DATE:
REVISIONS AND RECORD OF ISSUE
OF
PROJECT NO.:
43211/20(SCALE BAR IS 4" AT FULL SCALE)
D
FI
LE
PL
O
TT
ED
Black & Veatch Corporation
CARLTON WELLFIELD
REHABILITATION
JANUARY 2026
100% ISSUED
FOR BID
SARASOTA COUNTY UTILITIES
1001 SARASOTA CENTER
BOULEVARD
SARASOTA, FL 34240
THIS DRAWING WAS
ORIGINALLY SIGNED AND
SEALED BY JEFFREY S. MILLER,
A LICENSED PROFESSIONAL
ENGINEER IN THE STATE OF
UPS
UPS-XXA
PLC-XX
ESW-XXA
C
AT
CAT6
C
AT
ESW-XXB
FO
FPP-29A
FO
FD
421344
INSTRUMENTATION
CONTROL BLOCK
DIAGRAM AND DETAILS
KRW
AWR
APPROVED:
DESIGNED:
DETAILED:
CHECKED:
DATE:
REVISIONS AND RECORD OF ISSUE
OF
PROJECT NO.:
43211/20(SCALE BAR IS 4" AT FULL SCALE)
D
FI
LE
PL
O
TT
ED
Black & Veatch Corporation
CARLTON WELLFIELD
REHABILITATION
JANUARY 2026
100% ISSUED
FOR BID
SARASOTA COUNTY UTILITIES
1001 SARASOTA CENTER
BOULEVARD
SARASOTA, FL 34240
THIS DRAWING WAS
ORIGINALLY SIGNED AND
SEALED BY JEFFREY S. MILLER,
A LICENSED PROFESSIONAL
ENGINEER IN THE STATE OF
EXISTING 24F
UNDERGROUND FIBER
OPTICAL CABLE (TYPICAL)
FD
C :\U
SE
R
S\
SU
D
2\
AP
PD
AT
A\
LO
C
AL
\A
U
TO
D
ES
K\
AU
TO
C
AD
P
LA
N
T 3D
\C O
LL
AB
O R
AT
IO
N C
AC
H
E\
SY
ST
EM
W
ID
E W
EL
LF
IE
LD
A
SS
ES
SM
EN
T\
PI
D
D W
G \I-
.D
W G
1/
/2
6:
:0
AM
421344
I-04
INSTRUMENTATION
FIBER RING TOPOLOGY
KRW
AWR
APPROVED:
DESIGNED:
DETAILED:
CHECKED:
DATE:
REVISIONS AND RECORD OF ISSUE
OF
PROJECT NO.:
43211/20(SCALE BAR IS 4" AT FULL SCALE)
D
FI
LE
PL
O
TT
ED
Black & Veatch Corporation
CARLTON WELLFIELD
REHABILITATION
JANUARY 2026
100% ISSUED
FOR BID
SARASOTA COUNTY UTILITIES
1001 SARASOTA CENTER
BOULEVARD
SARASOTA, FL 34240
THIS DRAWING WAS
ORIGINALLY SIGNED AND
SEALED BY JEFFREY S. MILLER,
A LICENSED PROFESSIONAL
ENGINEER IN THE STATE OF