Plans.pdf

PDF 4 MB Posted

Attached to
File No. 751/17107. RAA - Escanaba Wildlife-Workshop Upgrades
Solicitation number
RFQ-171-180000000502-2
Issued by
Clinton County, Fruitport Village, Michigan

About this file

This is a set of architectural, mechanical, electrical and plumbing plans from the Michigan Department of Technology, Management and Budget for converting an existing workshop building located at Mead Road in Gladstone, MI (File No. 751/17107.RAA, Index No. 86350). The project involves converting a storage bay workshop building with upgrades including new infrared heaters, garage door vision panels, insulation, sheathing, vapor barriers, ceiling-mounted hose reels, and electrical modifications. Key mechanical work includes installing gas-fired infrared heaters with venting, a non-freeze yard hydrant, and ductwork insulation. Electrical modifications include new exterior lighting with motion sensors, outlets for garage door openers and an air compressor, and replacing existing light fixtures.

The plans detail specific technical requirements including installation of 7/16" sheathing with Class I or II vapor barriers, 3" spray foam insulation, and corrugated sheet metal ceiling treatments. The storage bay area is 2,540 SF with a 129 SF mezzanine. The building includes four overhead doors that will receive new vision panels. The mechanical systems specify LP gas supply with secondary regulators to provide 11" W.C. supply pressure. No pricing information, bid dates, or contract terms are included in these construction documents.

View the file

Other files

File Type Posted
Specifications.pdf PDF
Addendum_1.pdf PDF
BidSum.pdf PDF
Advertisement.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FILE NO.: 751 / 17107.RAA

INDEX NO.: 86350

STATE OF MICHIGAN

DEPARTMENT OF TECHNOLOGY, MANAGEMENT AND BUDGET

FACILITIES AND BUSINESS SERVICES ADMINISTRATION

DESIGN AND CONSTRUCTION DIVISION

ROBERT C. HALL, RA, NCARB, DIRECTOR

ENGINEERING

ARCHITECTURE

PLANNING

SURVEYING

ENVIRONMENTAL

PROJECT TITLE:

OWNER:

PROJECT LOCATION:

PROJECT NO:

DRAWN BY:

CHECKED:

APPROVED:

1 2 3 4 5

1 2 3 4 5

D

C

B

A

D

C

B

A

© U.P. Engineers & Architects, Inc.

DESIGNED BY:

DATE:ISSUED FOR:

100 PORTAGE STREET

HOUGHTON, MI 49931

(906) 482-4810

424 SOUTH PINE STREET

ISHPEMING, MI 49849

(906) 485-1011

707 ASHMUN ST.

SAULT STE. MARIE, MI 49783

(906) 635-0511

1701 DUNLAP AVE. SUITE B

MARINETTE, WI 54143

(715) 732-4188

2906 N. STEPHENSON AVE. SUITE 2

IRON MOUNTAIN, MI 49801

(906) 779-0937

P :\M

-1

D

TM

B -C on ve rt an

E x.

W or ks ho p bu ild in g\ D w gs

\M

-1

_W or ks ho p

B ld g.

rv t

1/

/2

1:

:4

P

M

G002

GENERAL INFORMATION

CONVERT EXISTING

WORKSHOP BUILDING

MICH. DEPT. OF

TECHNOLOGY,

MANAGEMENT &

BUDGET

MEAD RD.

GLADSTONE, MI 49837

M12-17322

RA

KD

KD

RA

ROOM, DOOR, & WINDOW

IDENTIFICATION NUMBERS

101 DOOR IDENTIFICATION NUMBER

1 WINDOW IDENTIFICATION NUMBER

ROOM IDENTIFICATION BY FLOOR AS FOLLOWS:

BASEMENT FLOORS

FIRST FLOORS

SECOND FLOORS

* CONTINUE FOR AS MANY FLOORS AS REQUIRED

DOOR IDENTIFICATION NUMBERS SHALL REPEAT ROOM NUMBER. MULTIPLE

DOORS IN A ROOM WILL USE A POSTSCRIPT LETTER FOR EACH ADDITIONAL

DOOR REQUIRED

SYMBOLS

TITLE

SCALE: 1/2" = 1'-0"1

DRAWING

NUMBER

ELEVATIONNU

MBER 1

A101SHEET WHERE

ELEVATION IS

FOUND

SHEET WHERE

ELEVATION IS

FOUND

ELEVATIONNU

MBER

A101

SECTION OR

DETAIL NUMBER

A101SHEET WHERE

SECTION OR

DETAIL IS

FOUND

A101

SECTION OR

DETAIL

NUMBER

SHEET WHERE

SECTION OR

DETAIL IS FOUND

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Q

R

S

T

U

V

W

Y

Z

A.B.

ABR.

ABS.

ABV.

AC.

A/C

ACC.

A.C.C.

AC. INSUL.

ACC. PNL.

ACT.

A.C.U.

ADD.

ADDN.

ADH.

ADJ.

A.F.F.

A.H.U.

AL.

ALT.

ALUM./AL.

AMP.

AMPL.

ANCH.

ANG.

APPR.

APPROX.

ARCH.

A.R.F.

ASPH.

A.S.R.

ASSY.

A.T.M.

AUTO.

AUX.

AVG.

AVS.

AW.

ANCHOR BOLT

ABRASIVE

ABSORBING

ABOVE

ACOUSTIC/ACOUSTICAL

AIR CONDITIONING

ACCESS

AIR CONDITIONING COMPRESSOR

ACOUSTIC INSULATION

ACCESS PANEL

ACOUSTIC TILE

AIR CONDITIONING UNIT

ADDENDUM

ADDITION

ADHESIVE

ADJUSTABLE

ABOVE FINISH FLOOR

AIR HANDLING UNIT

ACOUSTICALLY LINED

ALTERNATE

ALUMINUM

AMPERE

AMPLIFIER

ANCHOR

ANGLE

APPROVED

APPROXIMATE

ARCHITECT/ARCHITECTURAL

ABOVE REFERENCE FLOOR

ASPHALT

AUTOMATIC SPRINKLER RISER

ASSEMBLY

AUTOMATIC TELLER MACHINE

AUTOMATIC

AUXILIARY

AVERAGE

ACID VENT STACK

ACID WASTE

B.A.

BB.

B/B B.B.R.

B/C

BD.

B.D.D.

BDRY.

BETW.

BEV.

B.F.

BFE.

B.F.P.

B.I.

BIT.

B.L.

BLDG.

BLK.

BLKG.

BLR.

BLR. F.

BLR. H.

BLVD.

BM.

B.M.

B.N.

BOT.

BOT. EL.

B.PL.

BR.

B.R.

BRG.

BRK.

BRKR.

BRZ.

B.S.

BSMT.

BTU.

BULL.

B.U.R.

B.W.

BURGLAR ALARM

BALLED AND BURLAPPED

BACK-TO-BACK

BASE BOARD RADIATION

BACK OF CURB

BOARD

BACK DRAFT DAMPER

BOUNDARY

BETWEEN

BEVEL

BARRIER FREE

BOTTOM OF FOOTING ELEVATION

BACK FLOW PREVENTER

BLACK-IRON

BITUMINOUS

BUILDING LINE

BUILDING

BLOCK

BLOCKING

BOILER

BOILER FEED

BOILER HOUSE

BOULEVARD

BEAM

BENCH MARK

BULLNOSE

BOTTOM

BOTTOM ELEVATION

BASE PLATE

BRASS

BEDROOM

BEARING

BRICK

BREAKER

BRONZE

BOTH SIDES

BASEMENT

BRITISH THERMAL UNIT

BULLETIN

BUILT-UP ROOFING

BOTH WAYS

C-

CA.

CAB.

CAP.

CAT. NO.

CB.

C.BD.

C.BR.

C/C

C.CL.

CD.

C.C.

CEM.

CEM. PLAS.

CER.

CERT.

CF.

CFH.

CFM.

C.G.

CHAM.

CHAN. OR [

CHD.

CHG.

CHKD. PL.

CHWR.

CHWS.

C.I.

C.I.F.

C.I.P.

CIR.

CIRC.

CIRCUM.

C.J.

CL (CL)

CL.

CLG.

CLO.

CLR.

CLRM.

CLR. GL.

CLR. W.GL.

C.M.U.

CNTR.

CNVYR.

CO.

C.O.

COEF.

COL.

COMB.

COMPO.

COMPR.

COMPT.

CONC.

COND.

CONF.

CONN.

CONST.

CONT.

CONTR.

CONV.

COR.

CORR.

COV.

COV. PL.

C.P.

CPT.

CRS.

C.R.S.

CSG.

CSMT.

CSTG.

CSWRK.

C.T.

C.T.B.

CTR.

C.U.H.

CU. FT.

CULV.

CW.

CWR.

CWS.

CY.

CYC.

CYL.

CIVIL DRAWING-NO.

COMPRESSED AIR

CABINET

CAPACITY

CATALOG NUMBER

CATCH BASIN

CHALKBOARD

CIRCUIT BREAKER

CENTER-TO-CENTER

COAT CLOSET

CONDENSATE DRAIN

CEILING DIFFUSER

CEMENT

CEMENT PLASTER

CERAMIC

CERTIFIED

CEILING FAN

CUBIC FOOT PER HOUR

CUBIC FEET PER MINUTE

CORNER GUARD

CHAMFER

CHANNEL

CHORD

CHANGE

CHECKERED PLATE

CHILLED WATER RETURN

CHILLED WATER SUPPLY

CAST IRON

CAST IRON FRAME

CAST IRON PIPE/CAST-IN-PLACE

CIRCLE/CIRCULAR

CIRCUIT

CIRCUMFERENCE

CONTROL JOINT

CENTERLINE

CLOSET

CEILING

CLOSURE

CLEAR

CLASSROOM

CLEAR GLASS

CLEAR WIRE GLASS

CONCRETE MASONRY UNIT

COUNTER

CONVEY0R

COMPANY

CLEAN OUT

COEFFICIENT

COLUMN

COMBINATION

COMPOSITION

COMPRESSOR

COMPARTMENT

CONCRETE

CONDUIT

CONFERENCE

CONNECTION

CONSTRUCTION

CONTINUE/CONTINUOUS

CONTRACTOR

CONVECTOR

CORNER

CORRIDOR

COVER

COVER PLATE

CONTROL PANEL

CARPET

COURSE

CARPET REDUCER STRIP

CASING

CASEMENT

CASTING

CASEWORK

CERAMIC TILE

CERAMIC TILE BASE

CENTER

CABINET UNIT HEATER

CUBIC FEET/CUBIC FOOT

CULVERT

COLD WATER

CONDENSING WATER RETURN

CONDENSING WATER SUPPLY

CUBIC YARD

CYCLES

CYLINDER

D.

D.A.

DB.

D.B.

DBL.

DEG.

DEPR.

DEPT.

DES.

DET.

D.F.

DGM.

DIA.

DIAG.

DIFF.

DIM.

DIR.

DISC.

DISCONT.

DISP.

DIST.

DIV.

D.L.

DMPFG.

DMPR.

DN.

D.O.

DR.

DRN.

DR. OP.

D.S.

D.S.P.

D.T.

D.T.C.

DUP.

DW.

DWG.

DWL.

DWR.

DEEP

DOUBLE ACTION

DECIBEL

DRY BULB

DOUBLE

DEGREE(S)

DEPRESSED

DEPARTMENT

DESIGN

DETAIL

DRINKING FOUNTAIN

DIAGRAM

DIAMETER

DIAGONAL

DIFFUSER

DIMENSION

DIRECTORY

DISCONNECTED

DISCONTINUOUS

DISPENSER

DISTANCE

DIVIDER/DIVISION

DEAD LOAD

DAMP PROOFING

DAMPER

DOWN

DOOR OPENING

DOOR

DRAIN

DOOR OPERATOR

DOWN SPOUT

DRY STAND PIPE

DRAIN TILE

DRAIN TILE CONNECTOR

DUPLICATE

DISHWASHER

DRAWING

DOWEL

DRAWER

E.

E-

EA.

E.A.

E.C.

E.D.

E/E E.F.

E.G.

E.I.F.S.

E.J.

EL.

ELAST.

ELAST. FLASH.

ELAST. W.P.

ELEC.

ELEC. CL.

ELEC. CAB.

ELEC. OPER.

ELEV.

EMERG.

ENCL.

ENGR.

ENTR.

EP.

E.P.

EPDM.

EQ.

EQUIP.

EQUIV.

E.R.

ESP.

E.S.R.

EWC

EXCAV.

EXH.

EXIST.

EXP.

EXP.B.

EXP'D.

EXT.

EXTR.

EAST

ELECTRICAL DRAWING-NO.

EXHAUST AIR

EACH

ELECTRICAL CONTRACTOR

EXHAUST DUCT

END-TO-END

EXHAUST FAN

EXHAUST GRILLE

EXTERIOR INSULATION FINISH SYSTEM

EXPANSION JOINT

ELEVATION

ELASTOMERIC

ELASTOMERIC FLASHING

ELASTOMERIC WATERPROOFING

ELECTRIC/ELECTRICAL

ELECTRICAL CLOSET

ELECTRICAL CABINET

ELECTRICALLY OPERATED

ELEVATOR

EMERGENCY

ENCLOSURE

ENGINEER

ENTRANCE/ENTRY

EPOXY

ELECTRICAL PANEL

ETHYLENE PROPYLENE DIENE MONOMER

EQUAL

EQUIPMENT

EQUIVALENT

EXHAUST REGISTER

EXTERNAL STATIC PRESSURE

ELASTORMERIC SHEET ROOFING

ELECTRIC WATER COOLER

EXCAVATED

EXHAUST

EXISTING

EXPANSION

EXPANSION BOLT

EXPOSED

EXTERIOR

EXTRUDED

F.

F.A.

FAB.

F.A.C.P.

FAS.

F.BD.

FBGLS.

F. BRK.

F.C.

F.C.O.

F.C.U.

F.D.

FDN.

FDR.

F.D.V.

F.E.

F.E.C.

F/F

F.FIN.

F.H.

F.H.C.

FHMS.

FHWS.

FIG.

FIN.

FIN. FLR/F.F.

FIXT.

F.L.

FLASH.

FLDG.

FLEX.

FLR.

FLR. FIN.

FLUOR.

FM. BD.

FN

FP.

FPC.

FPM.

FPRFG.

FR.

F.R.

FR/COV.

FRMG.

F.R.P.

F.R.T.WD.

FRZR.

FS.

FT OR '

F&T

FTG.

FURN.

FURR.

FUT.

F.V.C.

FAHRENHEIT

FIRE ALARM

FABRICATED/FABRIC

FIRE ALARM CONTROL PANEL

FASTENER

FORM BOARD

FIBERGLASS

FIRE BRICK

FLEXIBLE CONNECTION

FLOOR CLEAN OUT

FAN COIL UNIT

FLOOR DRAIN

FOUNDATION

FEEDER

FIRE DEPARTMENT VALVE

FIRE EXTINGUISHER

FIRE EXTINGUISHER CABINET

FACE-TO-FACE

FACTORY FINISH

FIRE HYDRANT

FIRE HOSE CABINET

FLATHEAD MACHINE SCREW

FLATHEAD WOOD SCREW

FIGURE

FINISH/FINISHED

FINISH FLOOR

FIXTURE

FIRE LANE

FLASHING

FOLDING

FLEXIBLE

FLOOR

FLOOR FINISH

FLUORESCENT

FORMBOARD

FENCE

FIRE PROTECTION

FIRE PROTECTION CONTRACTOR

FEET PER MINUTE

FIREPROOFING

FRAME

FIRE RETARDANT/FIRE RATED

FRAME AND COVER

FRAMING

FIBERGLASS REINFORCED PANELING

FIRE RETARDANT TREATED WOOD

FREEZER

FLOOR SINK

FOOT

FLOAT AND THERMOSTATIC TRAP

FOOTING

FURNISH/FURNISHED

FURRING/FURRED

FUTURE

FIRE VALVE CABINET

G.

GA.

GAL.

GALV.

GALV. I.

G.B.

GC.

GEN.

GEN'L.

GFCI.

G.F.I.

G.H.T.

GI.

GL.

G.L.

GLZ.

GND.

GPH.

GPM.

GR.

GR. B.

GRT.

G.S.

GSKT.

GT.

G.T.

G.V.&B.

GYP.BD.

GAS

GAUGE

GALLON

GALVANIZED

GALVANIZED IRON

GRAB BAR

GENERAL CONTRACTOR

GENERATOR

GENERAL

GROUND FAULT CIRCUIT INTERRUPTER

GROUND FAULT INTERRUPTER

GLAZED HOLLOW TILE

GREASE INTERCEPTOR

GLASS

GRID LINE

GLAZING

GROUND

GALLONS PER HOUR

GALLON'S PER MINUTE

GRILLE

GRADE BEAM

GRAITE

GREASE SEPARATOR

GASKET

GROUT

GREASE TRAP

GATE VALVE AND BOX

GYPSUM BOARD

H H.

H.A. GL.

H.B.

G.BD.

GC.

H.C.

HD.

HDR.

HDWD.

HDWE.

HEX.

HGT.

HHWR.

HHWS.

H.I.D.

H.M.

H.O.

HORIZ.

HOSP.

HP.

H.P.

H.PR.

HR.

H.R.

H.R.V.

H.S.

H.S.B.

H.S.P.

HSTWY.

HTG.

HTR.

H.V.

H/V H.V.A.C.

H.V.C.

H.W.

HWR.

HWS.

HWY.

HX.

HYDROGEN

HIGH

HEAT ABSORBING GLASS

HOSE BIBB

HARDBOARD

HEATING COIL

HOLLOW CORE

HEAD

HEADER

HARDWOOD

HARDWARE

HEXAGON

HEIGHT

HEATING HOT WATER RETURN

HEATING HOT WATER SUPPLY

HIGH INTENSITY DISCHARGE

HOLLOW METAL

HUB OUTLET

HORIZONTAL

HOSPITAL

HORSEPOWER

HIGH POINT

HIGH PRESSURE

HOUR

HANDRAIL

HEAT RECOVERY VENTULATOR

HIGH STRENGTH

HIGH STRENGTH BOLT

HOSE STAND PIPE

HOIST WAY

HEATING

HEATER

HIGH VOLTAGE

HEATING AND VENTILATION

HEATING, VENTILATION, & AIR CONDITIONING

HOSE VALVE CABINET

HOT WATER

HOT WATER RETURN

HOT WATER SUPPLY

HIGHWAY

HEAT EXCHANGER

I.D.

I.E.

I.F.

IN. OR"

INCAND.

INCIN.

INCL.

INFO.

INST'L.

INSUL.

INT.

INTER.

INV.

I.W.

INSIDE DIAMETER

INVERT ELEVATION

INSIDE FACE

INCH/INCHES

INCANDESCENT

INCINERATOR

INCLUDE/INCLUDING

INFORMATION

INSTALL/INSTALLATION

INSULATE/INSULATION

INTERIOR

INTERMEDIATE

INVERT

INDIRECT WASTE

J.B.

J.C.

JST.

JT.

JUNCTION BOX

JANITOR CLOSET

JOIST

JOINT

K.D.

K.O.P.

K.P.

KV.

KVA.

KW.

KNOCK DOWN

KNOCK-OUT PANEL

KICK PLATE

KILOVOLT

KILOVOLT AMPERE

KILOWATT

L-

LAB.

LAM.

LAV.

L.B.

LBL.

LBR.

LBS. OR#

LDG.

LDRY.

LEV.

L.F.

LGTH.

L.H.

L.H.R.B.

LIN.

LIN. DIFF.

LIQ.

L.L.

L.L.H.

L.L.V.

LMST.

L.O.

L.P.

L.P.G.

L.PR.

LPRF.

L.R.P.

LT.

LTG.

LTL.

LTWT.

LTWT. CONC.

LVR.

LANDSCAPE DRAWING-NO

LABORATORY

LAMINATE/LAMINATED

LAVATORY

LAG BOLT

LABEL

LUMBER

POUNDS

LANDING

LAUNDRY

LEVEL

LINEAR FEET/FOOT

LENGTH

LEFT HAND

LEFT HAND REVERSE BEVEL

LINEAR

LINEAR DIFFUSER

LIQUID

LIVE LOAD

LONG LEG HORIZONTAL

LONG LEG VERTICAL

LIMESTONE

LOUVER OPENING

LOCATION

LIQUID PETROLEUM GAS

LOW PRESSURE

LIGHTPROOF

LIGHTING/RECEPTACAL PANEL

LIGHT

LIGHTING

LINTEL

LIGHTWEIGHT

LIGHTWEIGHT CONCRETE

LOUVER

M.

M-

MACH.

MACH. RM.

MAINT.

MAR.

MAS.

MATL.

M.A.U.

MAX.

M.B.

M.B.H.

M.C.

M.D.P.

M.D.S.

MECH.

MED.

MEMB.

M.E.S.

MET.

MET. W.P.

MEZZ.

MFGR.

MH.

M.I.

MIN.

MISC.

MIR.

M.L.

M.L. & PLAS.

MLDG

M.O.

MOD.

M.O.D.

MON.

MOV.

M.S.B.

M.T.

MTD.

MTG.

MULL.

MWK.

THOUSAND (1000)

MECHANICAL DRAWING-NO.

MACHINE

MACHINE ROOM

MAINTENANCE

MARBLE

MASONRY

MATERIAL

MAKE-UP AIR UNIT

MAXIMUM

MACHINE BOLT

1000 BRITISH THERMAL UNITS/HOUR

MECHANICAL CONTRACTOR

MAIN DISTRIBUTION PANEL

METAL DIVIDER STRIP

MECHANICAL

MEDIUM

MEMBRANE

METAL EDGE STRIP

METAL

METALLIC WATERPROOFING

MEZZANINE

MANUFACTURER

MANHOLE

MISCELLANEOUS IRON

MINIMUM

MISCELLANEOUS

MIRROR

METAL LATH

METAL LATH & PLASTER

MOLDING

MASONRY OPENING

MODEL

MOTOR OPERATED DAMPER

MONUMENT

MOVEABLE

MAIN SWITCH BOARD

METAL THRESHOLD

MOUNDED/ING

MEETING

MULLION

MILLWORK

N.

NAT.

NEUT.

N.I.C.

NO. OR #

NOS.

N.S.

N.T.S.

NORTH

NATURAL

NEUTRAL

NOT-IN-CONTRACT

NUMBER

NOSING

NEAR SIDE

NOT-TO-SCALE

O.A.

O.C.

O.D.

OFF.

OH.

OH.DR.

O/O

OPER.

OPG.

OPP.

OPQ.

ORIG.

ORN.

OZ.

OSB.

OXY.

OVERALL

ON CENTER

OUTSIDE DIAMETER

OFFICE

OVERHEAD

OVERHEAD DOOR

OUT-TO-OUT

OPERATOR

OPENING

OPPOSITE

OPAQUE

ORIGINAL

ORNAMENTAL

OUNCE

ORIENTED STRAND BOARD

OXYGEN

P. OR 0/

P.A.

PART.

PASS.

P.B.

P.BD.

PC.

P/C

PCF.

PCS.

PED.

PERIM.

PERM.

PERP.

PFN.

PG.

P.G.

P.H.

PHOTO.

P.I.V.

PKG.

PL.

P.L.

PLAS.

PLAT.

PLBG.

PLF.

PL. GL.

PL. LAM.

PLWD.

PNL.

PORT.

POS.

P.P.

PREFAB.

PRES.

PRIM.

PRL.

PROJ.

PROP.

PRTN.

P.R.V.

PSF.

PSI.

PT.

P.T.D.

P.T.WD.

P.T.W.R.

PVC.

PVMT.

PHASE

PUBLIC ADDRESS

PARTICLE

PASSAGE

PUSH BUTTON

PARTICLE BOARD

PIECE

PRECAST

POUNDS PER CUBIC FOOT

PIECES

PEDESTAL

PERIMETER

PERMANENT

PERPENDICULAR

PREFINISHED

PAGE

PRESSURE GAUGE

PHYSICALLY HANDICAPPED

PHOTOGRAPH

POST INDICATOR VALVE

PARKING

PLATE

PROPERTY LINE

PLASTER

PLATFORM

PLUMBING

POUNDS PER LINEAR FOOT

PLATE GLASS

PLASTIC LAMINATE

PLYWOOD

PANEL

PORTABLE

POSITION

POWER PANEL

PREFABRICATED

PRESSURE

PRIMARY

PARALLEL

PROJECT/PROJECTION

PROPERTY/PROPOSED

PARTITION

PRESSURE REDUCING VALVE

POUNDS PER SQUARE FOOT

POUNDS PER SQUARE INCH

POINT

PAPER TOWEL DISPENSER

PRESERVATIVE TREATED WOOD

PAPER TOWEL WASTE RECEPTACLE

POLYVINYL CHLORIDE

PAVEMENT

Q.T.

Q.T.B.

QTR.

QTR. RD.

QTY.

QUARRY TILE

QUARRY TILE BASE

QUARTER

QUARTER ROUND

QUANTITY

R.A.

R.A.D.

RAD. OR R.

R.A.F.

R.A.G.

R.A.R.

R.C.

RD.

R.D.

RECT.

REC.

RED.

REF.

REFL.

REFR.

REG.

REINF.

REM.

REP.

REPT.

REQ'D.

RET.

RF.

RFG.

RF.H.

R.H.

R.H.M.S.

R.H.R.B.

R.H.W.S.

RIO.

RND. OR O/

R.O.

R.O.W.

R.P.

RPM.

R.R.

R.S.

R.T.

R.T.U.

R.V.

RVT.

R.W.D.

RETURN AIR

RETURN AIR DIFFUSER

RADIUS

RETURN AIR FAN

RETURN AIR GRILLE

RETURN AIR REGISTER

ROOF CONDUCTOR

ROAD

ROOF DRAIN

RECTANGLE/RECTANGULAR

RECEIVE/RECEIVEING

REDUCER

REFER/REFERENCE

REFLECTED/REFLECTIVE

REFRIGERATOR

REGISTER

REINFORCE/REINFORCING/REINFORCEMENT

REMOVE/REMOVEABLE

REPAIR

RECEPTACLE

REQUIRED

RETURN

ROOF

ROOFING

ROOF HATCH

RIGHT HAND

ROUND HEAD MACHINE SCREW

RIGHT HAND REVERSE BEVEL

ROUND HEAD WOOD SCREW

ROUGH-IN-ONLY

ROUND

ROUGH OPENING

RIGHT OF WAY

RECEPTACLE PANEL

REVOLUTIONS PER MINUTE

RAILROAD

ROOF SUMP

RUBBER TILE

ROOF TOP UNIT

RELIEF VENT

RIVET

REDWOOD

S- S.

SA.

SAD.

SAF.

S.A.G.

SAN.

S.A.R.

S.A.T.

S.C.

SCHED.

S.C.R.

S.D.

S.DR.

SECT.

SERV.

S.F.

SGL.

SHT.

SHTHG.

SHT. MET.

SHWR.

SIM.

SK.

S.N.D.

S.N.R.

SNS.

SP.

S.P.

SPEC.

SPKLR.

SPKR.

SPR.

SPRYD.

SQ.

S.S.

S.STL.

ST.

STD.

STG.

STL.

STL. PL.

STM.

STOR.

STR.

STRUCT.

STS.

ST.STL.

SUB.

SUBST.

SUPP.

SURF.

SUSP.

SW.

S.W.

SWBD.

SWGR.

SYM.

SYS.

STRUCTURAL DRAWING-NO.

SOUTH

SUPPLY AIR

SUPPLY AIR DIFFUSER

SUPPLY AIR FAN

SUPPLY AIR GRILLE

SANITARY

SUPPLY AIR REGISTER

SUSPENDED ACOUSTIC TILE

SOLID CORE

SCHEDULE

SHOWER CURTAIN ROD

SMOKE DETECTOR

SHOWER DOOR

SECTION

SERVICE

SQUARE FEET/SQUARE FOOT

SINGLE

SHEET

SHEATHING

SHEET METAL

SHOWER

SIMILAR

SINK

SANITARY NAPKIN DISPENSER

SANITARY NAPKIN RECEPTACLE

SANITARY SEWER

SPACE

STATIC PRESSURE

SPECIFICATIONS

SPRINKLER

SPEAKER

SPARE

SPRAYED

SQUARE

SERVICE SINK

STRUCTURAL STEEL

STREET

STANDARD

SEATING

STEEL

STEEL PLATE

STEAM

STORAGE

STRAIGHT

STRUCTURAL

STORM SEWER

STAINLESS STEEL

SUBSTATION

SUBSTITUTE

SUPPORT

SURFACE/SURFACING

SUSPEND/SUSPENSION

SWITCH

SIDEWALK

SWITCHBOARD

SWITCH GEAR

SYMBOL

SYSTEM

U.C.

U.G.

U.H.

UNFIN.

U.N.O.

UR.

USGS.

U.SUB.

UTIL.

U.V.

UNDERCUT

UNDER GROUND

UNIT HEATER

UNFINISHED

UNLESS NOTED OTHERWISE

URINAL

UNITED STATES GEOLOGICAL SURVEY

UNIT SUBSTATION

UTILITY

UNIT VENTILATOR

VENT

VACUUM

VARIABLE

VARNISH

VARIABLE AIR VOLUME

VINYL BASE

VAPOR BARRIER

VOLUME CONTROL DAMPER

VINYL COMPOSITION TILE

VOLUME DAMPER

VENTILATE/VENTILATION

VERTICAL/VERTICALLY

VESTIBULE

VIBRATION ISOLATOR

VERIFY IN FIELD

VINYL FABRIC

VOLTS

VENEER

VINYL

VOLUME

VENEER PLASTER

VENT STACK

VENT THRU ROOF

V.

VAC.

VAR.

VARN.

VAV.

V.B.

V. BARR.

VCD.

VCT.

V.D.

VENT.

VERT.

VEST.

V.I.

V.I.F.

VIN. FAB.

VLT.

VNR.

VNY.

VOL.

V. PLAS.

VS.

VTR.

YARD

YIELD POINT

YIELD STRENGTH

YEAR

YD.

Y.P.

YR.

Y.S.

ZINCZC.

T.

TAG.

TAN.

T.B.

T&B

TC.

T/C

TCC.

T.D.

TD.&WR.

TECH.

T/EL.

TEL.

TEMP.

TEMP. GL.

TF.

T/F T.G.

T/G T&G

THD.

THERM.

THK.

THRESH.

THRU.

T/M T/P T/R

TRFR.

TS.

T.S.

T/S OR T.O.S.

T./TOIL.

T.U.

TV.

T.V.

TV.M.

T/W OR T.O.W.

TYP.

THREAD

TRANSFER AIR GRILLE

TANGENT

TEST BORING

TOP AND BOTTOM

TOP OF CONCRETE

TOP OF CURB

TEMPERATURE CONTROL CONTRACTOR

TRENCH DRAIN

TOWEL DISPENSER & WASTE RECEPTACLE

TECHNICAL

TOP ELEVATION

TELEPHONE

TEMPERATURE

TEMPERED GLASS

TRANSFER FAN

TOP OF FOOTING

TRANSFER GRILLE

TOP OF GUTTER

TONGUE AND GROOVE

THREAD

THERMOSTAT/THERMOMETER

THICK/THICKNESS

THRESHOLD

THROUGH

TOP OF MASONRY

TOP OF PAVEMENT

TOP OF RIM

TRANSFORMER

TUBE SECTION

THICKENED SLAB

TOP OF STEEL

TOILET

TERMINAL UNIT

TELEVISION

TURNING VANE

TELEVISION MONITOR

TOP OF WALL

TYPICAL

W.

W/

WAINS.

W.C.

W.CAB.

W.C.O.

WD.

WDW.

W.F.

W.G.

W.GL.

W.H.

W.L.

W.M.

W.O.

W/O

WP.

W.P.

W.PT.

W.R.

W.STPG.

WT.

W.V.

W/W W.W.F.

WWM.

W_x_

WASTE/WATTS

WITH

WAINSCOT

WATER CLOSET

WALL CABINET

WALL CLEAN OUT

WOOD

WINDOW

WASH FOUNTAIN

WATER GAUGE

WIRE GLASS

WATER HEATER

WORKING LINE

WIRE MESH

WINDOW OPENING

WITHOUT

WATERPROOFING

WEATHERPROOFING

WORKING POINT

WASTE RECEPTACLE

WEATHER STRIPPING

WEIGHT

WALL VENT

WALL-TO-WALL

WELDED WIRE FABRIC

WELDED WIRE MESH

WIDE FLANGE SECTION

ABBREVIATIONS

SYMBOLS

AND&

ANGLE

CENTERLINE

DIAMETER OR ROUND

AT@

BY (AS IN 6' X 8')X

PER/

PROPERTY LINE

CL

Ø

PL

MISCELLANEOUS:

1. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AT THE JOB SITE.

2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SHORING AND

BRACING AND SHALL DISCUSS THEIR METHODS WITH THE ARCHITECT

PRIOR TO THE START OF WORK.

3. ALL EQUIPMENT PENETRATIONS SHALL BE VERIFIED BY CONTRACTOR.

4. DO NOT SCALE THE DRAWINGS TO DETERMINE BUILDING DIMENSIONS.

FILE NO. 751/17107.RAA

90% REVIEW 01/19/2018

UP

DN

64' - 5 1/2"

8'

- 0

8'

- 0

8'

- 0

8'

- 0

8'

- 0

2 3/4"

2 3/4" 2' - 4 1/2" 5 1/2"

OH DOOR

12' - 0" 5 1/2" 2' - 4 1/2" 5 1/2"

OH DOOR

12' - 0" 5 1/2" 2' - 4 1/2" 5 1/2"

OH DOOR

12' - 0" 5 1/2" 2' - 4 1/2" 5 1/2"

OH DOOR

12' - 0" 5 1/2" 2' - 4 1/2" 2 3/4"

2 3/4"

A101

D3

2540 SF

STORAGE BAY

C3 A102

A2 A102

A101 D4

A101

C1 TYP. @

INTERIOR

WALLS

EQ

UA

L 1'

- 9

/4

0"

EQ

UA

L

1/

2" 4'

- 5

/2

R.

O.

3'

- 4

/2

GAS-FIRED INFRARED

HEATER VENT PIPE, SEE

MECH. DWGS.

M

IN

GAS-FIRED INFRARED HEATER,

SEE MECH. DWGS.

GAS-FIRED INFRARED HEATER

INTAKE VENT, SEE MECH. DWGS.

ALIGN INFRARED

HEATERS

ALIGN INFRARED

HEATERS

ROUTE VENT PIPE

TO AVOID EXISTING

6x6 COLUMN

EXISTING GARAGE DOORS w/

NEW VISION PANELS, SEE ELEV'S

NOTE: NO VEHICLES OVER 10' - 0".

MINIMUM CLEARANCES FROM HEATER

MUST BE MAINTAINED FROM VEHICLES

PARKED BELOW HEATER.

THE POSTING OF SIGNS MAY BE REQUIRED

IN STORAGE AREAS REFERRING TO

CLEARANCES TO THE HEATER.

REFER TO INFRARED HEATER OPERATION

MANUAL FOR MORE INFORMATION.

A101 D1

NEW CEILING MOUTNED

DUPLEX OUTLET REEL,

TYP. OF (4)

HOSE BIBB, SEE

PLUMB. DWGS.

A101 B1

129 SF

MEZZANINE

5 1/2" 3' - 0"

7/

SH

EA

TH

IN

G

TY

P.

T O

'-0

" A .F

.F

1/

2"

IN

SU

LA

TI

ON

M

EZ

ZA

NI

NE

1/

2" I

NS

UL

AT

IO

N

7/

SH

EA

TH

IN

G

PROVIDE WIRE MESH ALONG FACE

OF MEZZANINE WALL TO AVOID

POTENTIAL CONTACT WITH

INFRARED HEATER VENT PIPE

GAS-FIRED INFRARED

HEATER VENT PIPE,

SEE MECH. DWGS.

GAS-FIRED INFRARED

HEATER, SEE MECH. DWGS.

NEW CEILING

MOUTNED HOSE

REEL, TYP. OF (4)

EXISTING GARAGE DOORS w/ NEW

VISION PANELS, TYP. @ OH DOORS

GAS-FIRED INFRARED HEATER

INTAKE VENT, TYP. OF (3).

SEE MECH. DWGS.

EXISTING RIDGE VENT TO REMAIN,

PROVIDE NEW MESH SCREENING

ALONG ENTIRE VENTED OPENING

NEW EXTERIOR LIGHT FIXTURE

w/ MOTION SENSOR, TYP. OF (3), SEE FIXTURE SCHEDULE

PLATE HEIGHT

114' - 0"

FIRST FLOOR

100' - 0"

MEZZANINE

108' - 0"

ROOF

121' - 10"

EX

IS

T' G

1/

2" 1/

2"

EX

IS

T' G

1/

2" 1/

2"

EXISTING METAL PANELSEXISTING 2x6 HORIZ.

FRAMING @ 24" O.C.

EXISTING 6x6 PRESSURE

TREATED WOOD COLUMN, TYP.

7/16" SHEATHING ON CLASS I OR CLASS II

VAPOR BARRIER ON 3" SPRAY FOAM

INSUL., BUTT AGAINST EXIST'G

MEZZANINE WALL

7/16" SHEATHING ON CLASS I OR

CLASS II VAPOR BARRIER ON 3"

SPRAY FOAM INSUL.

FACE OF MEZZANINE WALL

ALIGN SHEATHING w/ FACE OF 6x6 WD COLUMN

EXISTING METAL PANELSEXISTING 2x6 HORIZ.

FRAMING @ 24" O.C.

EXISTING 6x6

PRESSURE TREATED

WOOD COLUMN, TYP. 7/16" SHEATHING ON CLASS I OR CLASS II

VAPOR BARRIER ON 3" SPRAY FOAM INSUL.,

TERMINATE SHEATHING @ EACH FACE OF

EXISTING 6x6 WD COLUMN, TYP.

EX

IS

T' G

1/

2" 1/

2"

NEW 2x4 VERT.

FRAMING @ 24" O.C.

BUTT SHEATHING FLUSH AGAINST

EXISTING 6x6 COLUMNS, TYP.

EXISTING 6x6 PRESSURE

TREATED WOOD COLUMN, TYP.

7/16" SHEATHING ON CLASS I OR CLASS II

VAPOR BARRIER ON 3" SPRAY FOAM

INSUL., TERMINATE SHEATHING @ EACH

FACE OF EXISTING 6x6 WD COLUMN, TYP.

NEW 2x4 VERT.

FRAMING @ EACH END

BUTT SHEATHING FLUSH AGAINST

EXISTING 6x6 COLUMNS, TYP.

EXISTING 6x6 PRESSURE

TREATED WOOD COLUMN, TYP.

EXISTING BOLLARDS

EXISTING O.H. DOOR EXISTING O.H. DOOR

EXISTING METAL PANELS

FILE NO.: 751 / 17107.RAA

INDEX NO.: 86350

STATE OF MICHIGAN

DEPARTMENT OF TECHNOLOGY, MANAGEMENT AND BUDGET

FACILITIES AND BUSINESS SERVICES ADMINISTRATION

DESIGN AND CONSTRUCTION DIVISION

ROBERT C. HALL, RA, NCARB, DIRECTOR

ENGINEERING

ARCHITECTURE

PLANNING

SURVEYING

ENVIRONMENTAL

PROJECT TITLE:

OWNER:

PROJECT LOCATION:

PROJECT NO:

DRAWN BY:

CHECKED:

APPROVED:

1 2 3 4 5

1 2 3 4 5

D

C

B

A

D

C

B

A

© U.P. Engineers & Architects, Inc.

DESIGNED BY:

DATE:ISSUED FOR:

100 PORTAGE STREET

HOUGHTON, MI 49931

(906) 482-4810

424 SOUTH PINE STREET

ISHPEMING, MI 49849

(906) 485-1011

707 ASHMUN ST.

SAULT STE. MARIE, MI 49783

(906) 635-0511

1701 DUNLAP AVE. SUITE B

MARINETTE, WI 54143

(715) 732-4188

2906 N. STEPHENSON AVE. SUITE 2

IRON MOUNTAIN, MI 49801

(906) 779-0937

P :\M

-1

D

TM

B -C on ve rt an

E x.

W or ks ho p bu ild in g\ D w gs

\M

-1

_W or ks ho p

B ld g.

rv t

1/

/2

1:

:3

P

M

A101

PLANS & ELEVATIONS

CONVERT EXISTING

WORKSHOP BUILDING

MICH. DEPT. OF

TECHNOLOGY,

MANAGEMENT &

BUDGET

MEAD RD.

GLADSTONE, MI 49837

M12-17322

RA

KD

KD

RA

1/4" = 1'-0"A2 FIRST FLOOR PLAN

1/4" = 1'-0"A1 MEZZANINE PLAN

1/8" = 1'-0"D3 FRONT ELEVATION

1/8" = 1'-0"D4 SIDE ELEVATION

1" = 1'-0"C1 ENLG PLAN @ TRANSITION

1" = 1'-0"B1 ENLG PLAN @ TYPICAL WALL

PROJECT

NORTH

TRUE

NORTH

PROJECT

NORTH

TRUE

NORTH

FILE NO. 751/17107.RAA

1" = 1'-0"D1 ENLG PLAN @ GARAGE DOORS

PLATE HEIGHT

114' - 0"

FIRST FLOOR

100' - 0"

MEZZANINE

108' - 0"

ROOF

121' - 10"

NEW 7/16" SHEATHING ON

BLOW-IN INSULATION

MOUNTED BETWEEN 6x6

COLUMNS (TYP.)

CARRY INSULATION AND

SHEATHING TO UNDERSIDE OF

ROOF TRUSSES, TYP.

GAS-FIRED INFRARED

HEATER, MOUNTED 6" (MIN.)

BELOW CEILING. SEE MECH.

SHEET METAL CEILING MOUNTED TO

UNDERSIDE OF ROOF JOISTS w/ 14" BLOW-IN

INSUL. ABOVE CEILING, BETWEEN TRUSSES

EXISTING RIDGE VENT TO REMAIN, PROVIDE

NEW MESH SCREENING @ INTERIOR, ALONG

ENTIRE VENTED OPENING

MOUNT GARAGE DOOR ANTENNA

RECEIVERS @ WALL ABOVE DOOR

EXISTING GARAGE DOORS

w/ NEW VISION PANELS, SEE ELEV'S

6"

GAS-FIRED INFRARED HEATER

INTAKE VENT, SEE MECH. DWGS.

GAS-FIRED INFRARED

HEATER VENT PIPE,

SEE MECH. DWGS.

1' - 6"

SNOW GUARD / ICE BREAKER MOUNTED TO

EXISTING STANDING SEAM METAL ROOF SYSTEM

NEW 7/16" OSB SHEATHING

ON RIGID INSULATION, SEE

FLOOR PLAN

TYP.

2' - 0"

2'

- 6

36"x36" ATTIC VENT, TYP. @ BOTH ENDS

PLATE HEIGHT

114' - 0"

FIRST FLOOR

100' - 0"

CARRY INSULATION

AND SHEATHING TO

UNDERSIDE OF ROOF

TRUSSES, TYP.

SHEET METAL CEILING

MOUNTED TO UNDERSIDE

OF ROOF JOISTS

14" BLOW-IN INSULATION ABOVE

CEILING, BETWEEN TRUSSES

GAS-FIRED INFRARED HEATER,

TYP. OF (3), SEE MECH. DWGS.

EXISTING GARAGE DOORS w/

NEW VISION PANELS, TYP.

MOUNT GARAGE DOOR

ANTENNA RECEIVERS @

WALL ABOVE DOOR

6" C

LE

AR

T

OP

M

IN

8"

A102 D1 36"x36" ATTIC VENT, TYP. @ BOTH ENDS

EXISTING GARAGE DOORS w/

NEW VISION PANELS, TYP.

NEW 7/16" OSB SHEATHING w/ 3-1/2" BLOW-IN INSUL., TYP. @ EXISTING GARAGE DOORS, SEE PLAN

NEW 7/16" OSB SHEATHING w/ 3-1/2" BLOW-IN INSUL., TYP. @ EXISTING GARAGE DOORS, SEE PLAN

2'

- 0

6' - 0"

2'

- 0

6' - 0" 6' - 0"

2'

- 0

SNOW GUARD / ICE BREAKER MOUNTED

TO EXISTING STANDING SEAM METAL

ROOF SYSTEM, TYP. OF (3) GAS-FIRED INFRARED HEATER

VENT PIPE, SEE MECH. DWGS.

EXISTING RIDGE VENT TO REMAIN, PROVIDE

NEW MESH SCREENING @ INTERIOR,

ALONG ENTIRE VENTED OPENING

PLATE HEIGHT

114' - 0"

TYP.

4' - 0" O.C.

PROVIDE 14" OF BLOW-IN

INSULATION, MINIMUM

CORRUGATED SHEET METAL CEILING

MOUNTED TO 7/16" OSB SHEATHING ON CLASS I

OR CLASS II VAPOR RETARDER MOUNTED TO

UNDERSIDE OF EXISTING WOOD TRUSSES

M

IN

ADD. ALT. #1

CORRUGATED SHEET METAL CEILING

MOUNTED TO 1" FURRING STRIPS ON CLASS I

OR CLASS II VAPOR RETARDER MOUNTED TO

UNDERSIDE OF EXISTING WOOD TRUSSES.

FILE NO.: 751 / 17107.RAA

INDEX NO.: 86350

STATE OF MICHIGAN

DEPARTMENT OF TECHNOLOGY, MANAGEMENT AND BUDGET

FACILITIES AND BUSINESS SERVICES ADMINISTRATION

DESIGN AND CONSTRUCTION DIVISION

ROBERT C. HALL, RA, NCARB, DIRECTOR

ENGINEERING

ARCHITECTURE

PLANNING

SURVEYING

ENVIRONMENTAL

PROJECT TITLE:

OWNER:

PROJECT LOCATION:

PROJECT NO:

DRAWN BY:

CHECKED:

APPROVED:

1 2 3 4 5

1 2 3 4 5

D

C

B

A

D

C

B

A

© U.P. Engineers & Architects, Inc.

DESIGNED BY:

DATE:ISSUED FOR:

100 PORTAGE STREET

HOUGHTON, MI 49931

(906) 482-4810

424 SOUTH PINE STREET

ISHPEMING, MI 49849

(906) 485-1011

707 ASHMUN ST.

SAULT STE. MARIE, MI 49783

(906) 635-0511

1701 DUNLAP AVE. SUITE B

MARINETTE, WI 54143

(715) 732-4188

2906 N. STEPHENSON AVE. SUITE 2

IRON MOUNTAIN, MI 49801

(906) 779-0937

P :\M

-1

D

TM

B -C on ve rt an

E x.

W or ks ho p bu ild in g\ D w gs

\M

-1

_W or ks ho p

B ld g.

rv t

1/

/2

1:

:3

P

M

A102

WALL SECTIONS

CONVERT EXISTING

WORKSHOP BUILDING

MICH. DEPT. OF

TECHNOLOGY,

MANAGEMENT &

BUDGET

MEAD RD.

GLADSTONE, MI 49837

M12-17322

RA

KD

KD

RA

1/4" = 1'-0"C3 BUILDING SECTION 1

1/4" = 1'-0"A2 BUILDING SECTION 2

1/8" = 1'-0"A1 ROOF PLAN

1" = 1'-0"D1 SECTION @ CEILING

FILE NO. 751/17107.RAA

ABBREVIATIONS NOTES

MECHANICAL AND PLUMBING ABBREVIATIONS, SYMBOLS AND NOTES

SYMBOLS LEGEND

ACCU AIR COOLED CONDENSING UNIT

ACL ACOUSTICAL LINED DUCT

AFF ABOVE FINISHED FLOOR

AHU AIR HANGING UNIT

AI ANALOG INPUT

AO ANALOG OUTPUT

AP ACCESS PANEL IN WALL OR CEILING

APD AIR PRESSURE DROP

AS AIR SEPARATOR

ASHP AIR SOURCE HEAT PUMP

B BOILER

BB BASEBOARD

BC BOOSTER COIL

BDD BACKDRAFT DAMPER

BFG BELOW FINISHED GRADE

BFP BACKFLOW PREVENTER

BHP BRAKE HORSE POWER

BJ BETWEEN JOIST

BOD BOTTOM OF DUCT

BOP BOTTOM OF PIPE

BT BATH TUB

BTU BRITISH THERMAL UNITS

BTUH BRITISH THERMAL UNITS PER HOUR

C CONVECTOR

CA COMPRESSED AIR

CB CATCH BASIN

CC COOLING COIL

CCF 100 CUBIC FEET

CD CEILING DIFFUSER

CF CUBIC FEET

CFH CUBIC FEET PER MINUTE

CFP CLEAN OUT FERRULE AND PLUG

CH CHILLER

CI CAST IRON

CHWR CHILLED WATER RETURN

CHWS CHILLED WATER SUPPLY

CJ CONTROL JOINT

CO CLEAN OUT

CO CARBON MONOXIDE

COND CONDENSATE

CO2 CARBON DIOXIDE

CP CIRCULATING PUMP

CS CIRCUIT SETTER

CT COOLING TOWER

CU CONDENSING UNIT

CU FT CUBIC FOOT

CUH CABINET UNIT HEATER

CW COLD WATER

CWR CONDENSER WATER RETURN

CWS CONDENSER WATER SUPPLY

D DIFFUSER

CB CRY BULB

DEG F DEGREE FAHRENHEIT

DF DRINKING FOUNTAIN

DH DUCT HEATER

DI DIGITAL INPUT

DIA DIAMETER

DN DOWN

DO DIGITAL OUTPUT

DWV DRAIN, WASTE AND VENT

EA EACH

EAT ENTERING AIR TEMPERATURE

EC ELECTRICAL CONTRACTOR

EDH ELECTRIC DUCT HEATER

EF EXHAUST FAN

EG EXHAUST AIR GRILLE

ELEV ELEVATION

ER EXHAUST AIR REGISTER

ES EMERGENCY SHOWER

EUH ELECTRIC UNIT HEATER

EWC ELECTRIC WATER COOLER

EWH ELECTRIC WATER HEATER

EWT ENTERING WATER TEMPERATURE

EX EXISTING

EXA EXHAUST AIR

EXH EXHAUST

F FIRE DAMPER

FAI FRESH AIR INTAKE

FBO FURNISHED BY OTHERS

FC FAN COIL

FD FLOOR DRAIN

FD FIRE DAMPER

FHB FROST PROOF HOSE BIB

FIN FIN TUBE RADIATION

FLG FLANGE

FMB FILTER MIXING BOX

FO FLAT OVAL

FP FIRE PROTECTION

FPM FEET PER MINUTE

FT FOOT OR FEET

FUR FURNACE

F&T FLOAT AND THERMOSTATIC TRAP

G GAS (NATURAL)

GAL GALLON

GC GENERAL CONTRACTOR

GPH GALLONS PER HOUR

GPM GALLONS PER MINUTE

GRV GRAVITY ROOF VENTILATOR

GT GREASE TRAP

GWH GAS WATER HEATER

H HYDROGEN

HB HOSE BIB

HC HEATING COIL

HCO HORIZONTAL CLEANOUT

HP HORSE POWER

HTR HEATER

HVAC HEATING, VENTILATING & AIR CONDITIONING

HW HOT WATER

HWC DOMESTIC HOT WATER RECIRCULATING

HWR HOT WATER RETURN

HWS HOT WATER SUPPLY

HX HEAT EXCHANGER

IE INVERT ELEVATION

IF INLINE FAN

IN INCH OR INCHES

INSUL INSULATION

IP IRON PIPE

INV INVERT

IWH INSTANTANEOUS WATER HEATER

JAN JANITOR

JC JANITOR'S CLOSET

JS JANITOR'S SINK

KW KILOWATT

LAT LEAVING AIR TEMPERATURE

LAV LAVATORY

LBS POUNDS

LHWR LOW TEMPERATURE HOT WATER RETURN

LHWS LOW TEMPERATURE HOT WATER SUPPLY

LIQ LIQUID (REFRIGERATION)

LV LOUVER

LP PROPANE GAS (LIQUID)

LWT LEAVING WATER TEMPERATURE

M METER

MAHU MAKE-UP AIR HANDLING UNIT

MAX MAXIMUM

MB MOP BASIN

MBH BRITISH THERMAL UNITS (1000)

MNTUH BRITISH THERMAL UNITS (1000)

MC MECHANICAL CONTRACTOR

MCA MINIMUM CIRCUIT AMPACITY

MD MOTORIZED DAMPER

MECH MECHANICAL

MIN MINIMUM

MOCP MAXIMUM OVER CURRENT PROTECTION

MS MOTOR STARTER

N20 NITROUS OXIDE

NC NORMALLY CLOSED

NIC NOT INCLUDED OR NOT IN CONTRACT

NIT NITROGEN

NO NORMALLY OPEN

OA OUTDOOR AIR

OAI OUTDOOR AIR INTAKE

OC ON CENTER

OD OVERFLOW DRAIN

ODP OPEN DRIP PROOF

ORD OVERFLOW ROOF DRAIN

OXY OXYGEN

P PUMP

PC PLUMBING CONTRACTOR

PD PUMPED DISCHARGE

PE PIPING ENCLOSURE

PD PNEUMATIC OPERATED DAMPER

PIV POST INDICATING VALVE

PRV PRESSURE REDUCING VALVE

PT PRESSURE TEMPERATURE PLUG

PTAC PACKAGED TERMINAL AIR CONDITIONING UNIT

PVAC PROCESS VACUUM

R REGISTER

RA RETURN AIR

RD ROOF DRAIN

RET RETURN

RF RETURN FAN

RG RETURN AIR GRILLE

RHC REHEAT COIL

RPZ REDUCED PRESSURE ZONE BACKFLOW PREVENTER

RR RETURN REGISTER

RTU ROOF TOP UNIT

S SINK

SA SUPPLY AIR

SAD SUPPLY AIR DIFFUSER

SAF SUPPLY AIR FAN

SAN SANITARY SEWER

SD SMOKE DETECTOR

SDP SMOKE DAMPER

SG SUPPLY AIR GRILLE

SH SHOWER HEAD

SHC STEAM HEATING COIL

SR SUPPLY REGISTER

SS STAINLESS STEEL

ST STORM

STM STEAM

SUCT SUCTION (REFRIGERATION)

SW SOFT WATER

TCC TEMPERATURE CONTROL CONTRACTOR

TCD TEMPERATURE CONTROL DAMPER

TCP TEMPERATURE CONTROL PANEL

TD TRANSFER DUCT

TG TRANSFER AIR GRILLE

TT TERMOSTATIC TRAP

TYP TYPICAL

UG UNDERGROUND

UH UNIT HEATER

UV UNIT VENTILATOR

V VENT

VAC VACUUM

VAV VARIABLE AIR VOLUME BOX

VD VOLUME DAMPER

VFD VARIABLE FREQUENCY DRIVE

VS VENT STACK (SANITARY)

VTR VENT THRU ROOF (SANITARY)

VUV VERTICAL UNIT VENTILATOR

W WASTE

WB WET BULB

WC WATER CLOSET

W/O WITHOUT

WH WATER HEATER

WSHP WATER SOURCE HEAT PUMP

NOTE:

NOT ALL ABBREVIATIONS AND/OR SYMBOLS ARE USED IN

THIS SET OF DOCUMENTS

MECHANICAL AND PLUMBING GENERAL NOTES

1. THESE DRAWINGS ARE DIAGRAMMATIC IN CHARACTER AND DO NOT NECESSARILY INDICATE EVERY OFFSET, VALVE, FITTING, ETC. REQUIRED. CONTRACTOR IS RESPONSIBLE FOR FIELD ROUTING ALL DUCTWORK AND PIPING AT NO ADDITIONAL COST.

2. EXISTING CONDITIONS SHOWN ON THESE DRAWINGS HAVE BEEN OBTAINED FROM EXISTING DRAWINGS AND / OR FIELD INSPECTIONS. CONTRACTOR SHALL FIELD VERIFY EXACT LOCATIONS AT TIME OF CONSTRUCTION. THIS DRAWING IS PART OF A SET

OF DRAWINGS AND SPECIFICATIONS, AND ALL SHALL BE USED AS A COMPLETE SET.

3. CONTRACTOR SHALL SECURE AND PAY FOR ANY AND ALL PERMITS AND INSPECTION FEES APPLICABLE TO THE WORK, AND PAY FOR ALL STATE AND FEDERAL TAXES IMPOSED. ALL TAXES FOR MATERIALS AND EQUIPMENT THAT ARE PERMANENTLY INSTALLED

SHALL BE INCLUDED AS A LINE ITEM ON THE BID FORM.

4. VERIFY ALL LAYOUTS, DIMENSIONS, CLEARANCES, AND METHODS WITH EQUIPMENT SUPPLIERS AND ALL TRADES.

COORDINATE WITH OWNER FOR REQUIREMENTS PERTAINING TO ALL OWNER FURNISHED EQUIPMENT.

5. CONTRACTOR SHALL BE RESPONSIBLE FOR PROJECT COORDINATION WITH OTHER TRADES AND SUPERVISION OF THEIR

OWN SUB-CONTRACTORS.

6. CONTRACTORS SHALL SUBMIT, REVIEW, AND COORDINATE ALL EXISTING BUILDING SHUTDOWNS WITH OWNER PRIOR TO

SCHEDULING AND OPERATIONS.

7. EACH CONTRACTOR SHALL PERFORM ALL CUTTING AND PATCHING NECESSARY FOR INSTALLATION OF THEIR WORK.

CONTRACTORS SHALL REPAIR/PATCH ALL AREAS DISTURBED DURING DEMOLITION AND INSTALLATION TO MATCH SURROUNDING AREAS. MAINTAIN ALL FIRE RATED ASSEMBLY CONSTRUCTION WHEN APPLICABLE, CUTTING AND PATCHING NECESSARY TO EXPOSE

DEFECTIVE WORK FOR REPAIR WILL BE DONE AT THE CONTRACTORS EXPENSE.

8. CONTRACTORS SHALL PROVIDE REPLACEMENTS FOR CEILING SUPPORT WIRES REMOVED FOR NEW WORK.

9. CONTRACTORS ARE RESPONSIBLE FOR REMOVAL AND REPLACEMENT OF CEILING TILES AND CEILING GRID "T" BARS IN

ASSOCIATION WITH THEIR WORK.

10. MATERIALS WITHIN AIR PLENUMS SHALL BE NONCOMBUSTIBLE OR SHALL BE USED AND LABELED AS HAVING A FLAME SPREAD INDEX OF NOT MORE THAN 25 AND A SMOKE-DEVELOPED INDEX OF NOT MORE THAN 50 WHEN TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. COMBUSTIBLE MATERIALS IN PLENUMS SHALL BE FULLY ENCLOSED WITHIN ONE OF THE FOLLOWING:

A. CONTINUOUS NON-COMBUSTIBLE RACEWAY OR ENCLOSURE;

B. APPROVED GYPSUM BOARD ASSEMBLY;

C. MATERIALS LISTED AND LABELED FOR INSTALLATION WITHIN PLENUM (E.G. FIRE BARRIER PLENUM WRAP EQUAL TO

"3M - PLENUM WRAP 5A+ ").

11. PLANS AND SPECIFICATIONS ARE INTENDED TO CONFORM TO GOVERNING CODES AND STANDARDS. IF NON- CONFORMITIES ARE DISCOVERED, BRING SAME TO THE ATTENTION OF THE ENGINEER FOR CLARIFICATION BEFORE SUBMITTING BID OR PROCEEDING WITH WORK. CODE COMPLIANCE OF WORK INSTALLED WITHOUT SUCH CONSULTATION WILL BE THE

CONTRACTORS RESPONSIBILITY.

12. REFER TO ARCHITECTURAL SHEETS FOR FLOOR PLANS AND SECTIONS AS REQUIRED TO DETERMINE ROUTING

REQUIREMENTS AND POTENTIAL CONFLICTS.

13. CONTRACTORS SHALL COORDINATE WITH ALL OTHER TRADES FOR INSTALLATION OF ALL EQUIPMENT. CONTRACTORS SHALL FIELD VERIFY EXISTING CONDITIONS. PREPARE COORDINATION DRAWINGS AT A MINIMUM OF 1/2" - 1'-0" SCALE WHERE

ACCURATE COORDINATION IS REQUIRED.

14. MANUFACTURERS MODEL NUMBERS LISTED ON DRAWINGS ARE BASIS FOR DESIGN. CONTRACTOR MAY SUBMIT AN "APPROVED EQUAL" FOR REVIEW BY THE ENGINEER. REFER TO GENERAL CONDITIONS FOR PROCEDURES TO FOLLOW FOR SUBSTITUTIONS. DESIGNATION OF AN "APPROVED EQUAL" IS OF THE ENGINEER'S DISCRETION.

15 IF EQUIPMENT OTHER THAN AS SPECIFIED IN THESE BID DOCUMENTS IS PROVIDED, THE CONTRACTOR FURNISHING THE EQUIPMENT IS RESPONSIBLE FOR THE IMPACT OF ANY REDESIGN AND INSTALLATION COSTS, INCLUDING BOT NOT LIMITED TO:

STRUCTURE, FOUNDATIONS, ENVIRONMENTAL, UTILITIES, PIPING, DUCTWORK, WIRING, DEVICES, ETC.. REDESIGN SHALL BE

SUBJECT TO THE APPROVAL OF THE OWNER, ARCHITECT AND ENGINEER.

16. MATERIALS, VALVES, EQUIPMENT AND FIXTURES SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURERS' RECOMMENDATIONS. CONNECTIONS TO FIXTURES, DEVICES AND EQUIPMENT SHALL BE VERIFIED WITH MANUFACTURER'S

CERTIFIED DRAWINGS.

17. FINAL LOCATION OF ALL CEILING DIFFUSERS, REGISTERS, GRILLES, LIGHT FIXTURES, SPRINKLER HEADS, DEVICES, ETC.

SHALL BE INSTALLED PER REFLECTED CEILING PLAN AND LOCATED CONSISTENT WITH CEILING AS INSTALLED.

18. PROVIDE DIELECTRIC UNIONS AT ALL JUNCTIONS OF DISSIMILAR METALS.

19. INSTALL PIPING TO ALLOW FOR EXPANSION AND CONTRACTION WITHOUT STRESSING PIPE, JOINTS, OR CONNECTED

EQUIPMENT.

20. PROVIDE ALL VALVING FOR THE PROPER SECTIONALIZING, ZONING AND OPERATION OF PIPING SYSTEMS. PROVIDE ACCESS

PANELS AS REQUIRED FOR ACCESS TO VALVES.

21. ALL INSULATION AND JACKETS SHALL HAVE 25 OR LESS FLAME SPREAD, 50 OR LESS SMOKE DEVELOPED RATING.

22. PENETRATIONS OF FLOOR/CEILING ASSEMBLIES AND ASSEMBLIES REQUIRED TO HAVE A FIRE-RESISTANCE RATING SHALL BE PROTECTED IN ACCORDANCE WITH THE INTERNATIONAL BUILDING CODE. PROVIDE FIRE STOP INSULATION AND/OR CAULK (AND INTUMESCENT WRAP FIRE COLLARS FOR PLASTIC PIPE) WHERE PIPING OR DUCTWORK PENETRATE THE RATED ASSEMBLIES. REFER TO ARCHITECTURAL PLANS FOR LOCATION OF FIRE WALLS, FLOORS, CEILINGS FOR FIRE/SMOKE RATINGS. IN ADDITION TO ACCOUNT

FOR FIRE AND/OR SMOKE DAMPERS AND OTHER MEANS OF PROTECTION REQUIRED.

23. PROVIDE PIPE TAPE MARKERS CONFORMING TO ANSI AND ASME A13.1 STANDARDS. MINIMUM IDENTITY OF PIPING CONVEYING FLUID WITH FLOW DIRECTION ARROWS AROUND ENTIRE DIAMETER COVERING BOTH ENDS OF PIPE LABEL. INTERVAL OF

LABEL SPACING SHALL NOT EXCEED 25 FEET.

24. SUBMIT FOR REVIEW CERTIFIED EQUIPMENT AND FIXTURE DRAWINGS AND/OR SUBMITTALS TO THE ARCHITECT/ENGINEER FOR APPROVAL OF PLUMBING FIXTURES. ARCHITECT/ENGINEER REVIEW OF SHOP DRAWINGS, PRODUCT DATA OR SAMPLES DOES NOT RELIEVE THE CONTRACTOR FROM COMPLYING WITH REQUIREMENTS OF THE CONTRACT DOCUMENTS.

25. PROVIDE OPERATION AND MAINTENANCE MANUAL PRIOR TO PROJECT COMPLETION. THE MANUAL SHALL CONSIST OF, AT MINIMUM; REVIEWED EQUIPMENT DRAWINGS AND/OR SUBMITTALS WITH COLOR SAMPLES (IF APPLICABLE), AND OPERATING AND MAINTENANCE MANUALS. THE MANUAL SHALL ALSO CONTAIN INSPECTION AND TESTING REPORTS, M.S.D.S. INFORMATION FOR MATERIALS LEFT ON THE PROJECT LOCATION. AS-BUILT DRAWINGS MARKED IN RED, PREVENTIVE MAINTENANCE CHECKLIST, PARTS LISTS AND PRODUCT WARRANTY INFORMATION, PROVIDE EMERGENCY CONTACT LIST FOR ALL CONTRACTORS AND THEIR SUBCONTRACTORS WITH A BRIEF DESCRIPTION OF THE DISCIPLINE OF RESPONSIBILITY, INCLUDE IN EACH MANUAL CONTRACTORS GUARANTEES OF MATERIALS AND WORKMANSHIP, A MINIMUM OF ONE YEAR, AND EQUIPMENT WARRANTIES BEGINNING FROM DATE

OF OWNER ACCEPTANCE.

26. AT PROJECT COMPLETION AND PRIOR TO FINAL OWNER ACCEPTANCE PROVIDE OWNER INSTRUCTION FOR ALL

EQUIPMENT AND SYSTEMS OPERATION AND MAINTENANCE.

27. GUARANTEE ALL MATERIALS AND WORKMANSHIP FOR A PERIOD OF ONE YEAR AFTER OWNER ACCEPTANCE OF THE ENTIRE

PROJECT.

SUPPLY AIR DIFFUSER

VD

F

S

SF

M

S D

T

H

H

T

P

M

LINEAR DIFFUSER

RETURN OR EXHAUST AIR GRILLE

EXHAUTS FAN - ROOF

FRESH AIR INTAKE HOOD - ROOF

RELIEF AIR HOOD - ROOF

SUPPLY REGISTER

RETURN OR EXHAUST REGISTER

SQUARE TO ROUND TRANSITION

VOLUME CONTROL DAMPER

FIRE DAMPER (RATING DETERMINED BY WALL TYPE)

SMOKE DAMPER

COMBINATION FIRE / SMOKE DAMPER

MOTORIZED DAMPER

DUCT SMOKE DETECTOR

THERMOSTAT - 48" A.F.F.

HUMIDISTAT - 48" A.F.F.

AIR FLOW

TEMPERATURE SENSOR

HUMIDITY SENSOR

PRESSURE SENSOR

SUPPLY AIR DUCT UP

SUPPLY AIR DUCT DOWN

RETURN AIR DUCT UP

RETURN AIR DUCT DOWN

EXHAUST AIR DUCT UP

EXHAUST AIR DUCT DOWN

BALL VALVE

BUTTERFLY VAVLE

CIRCUIT SETTER

CHECK VALVE

GATE VALVE

GLOBE VALVE

GAS VALVE OR PLUG VALVE

2-WAY CONTROL VALVE

3-WAY CONTROL VALVE

PRESSURE RELIEF VALVE

BALANCE VALVE

INLINE PUMP

REDUCED PRESSURE PRINCIPLE BACK

FLOW PREVENTER

STRAINER

WATER HAMMER ARRESTOR

CAP

PIPING 90

PIPING "T"

HUMIDIFIER

METER

CONNECTION TO EXISTING

M

PIPE BREAK

PIPE DOWN

PIPE UP

CLEAN OUT

GAS METER

UNION

HOSE BIBB

FLOW DETECTOR / SWITCH

VALVE WITH TAMPER SWITCH

ELECTRIC BELL

SIDEWALL SPRINKLER HEAD

CONCEALED SPRINKLER HEAD

PENDANT SPRINKLER HEAD

UPRIGHT SPRINKLER HEAD

SIAMESE CONNECTION

BASE FIN TUBE ELEMENT

FINE TUBE ELEMENT WITH COVER

EXTERNALLY INSULATED DUCTWORK

INTERNALLY INSULATED DUCTWORK

PLUMBING PIPING

MECHANICAL PIPING

DUCTWORK

DOMESTIC COLD WATER - EXISTINGCW

CW

CW

DOMESTIC COLD WATER - DEMO

DOMESTIC COLD WATER - NEW

HW DOMESTIC HOT WATER - EXISTING

HW DOMESTIC HOT WATER - DEMO

HW DOMESTIC HOT WATER - NEW

HWC DOMESTIC HOT WATER RECIRC. - EXISTING

DOMESTIC HOT WATER RECIRC. - DEMOHWC

HWC DOMESTIC HOT WATER RECIRC. - NEW

SAN SANITARY - EXISTING

SAN SANITARY - DEMO

SAN SANITARY - NEW

V VENT - EXISTING

V VENT - DEMO

V VENT - NEW

ST STORM - EXISTING

ST STORM - DEMO

ST STORM - NEW

G GAS - EXISTING

G GAS - DEMO

G GAS - NEW

HWS HYDRONIC HOT WATER SUPPLY - EXISTING

HWS

HWS

HYDRONIC HOT WATER SUPPLY - DEMO

HYDRONIC HOT WATER SUPPLY - NEW

HWR HYDRONIC HOT WATER RETURN - EXISTING

HWR HYDRONIC HOT WATER RETURN - DEMO

HWR HYDRONIC HOT WATER RETURN - NEW

FP FIRE PROTECTION - EXISTING

FP FIRE PROTECTION - DEMO

FIRE PROTECTION - NEWFP

CDS CONDENSOR WATER SUPPLY

CDS

CDS

CONDENSOR WATER SUPPLY - DEMO

CONDENSOR WATER SUPPLY - EXIST

CDR CONDENSOR WATER RETURN

CDR

CDR

CONDENSOR WATER RETURN - DEMO

CONDENSOR WATER RETURN - EXIST

CWS CHILLED WATER SUPPLY

CWS CHILLED WATER SUPPLY - DEMO

CWS CHILLED WATER SUPPLY - EXIST

CWR CHILLED WATER RETURN

CWR CHILLED WATER RETURN - DEMO

CWR CHILLED WATER RETURN - EXIST

AIR COMPRESSED AIR - EXISTING

AIR COMPRESSED AIR - DEMO

AIR COMPRESSED AIR - NEW

STM STEAM - EXISTING

STM STEAM - DEMO

STM STEAM - NEW

C CONDENSATE - EXISTING

C CONDENSATE - DEMO

C CONDENSATE - NEW

EXHAUST AIR DUCT - NEW

EXHAUST AIR DUCT - DEMO

EXHAUST AIR DUCT - EXISTING

24x14 EA

24x14 EA

24x14 EA

24x14 OA

24x14 OA

24x14 OA

24x14 RA

24x14 RA

24x14 RA

24x14 SA

24x14 SA

24x14 SA

OUTSIDE AIR DUCT - NEW

OUTSIDE AIR DUCT - DEMO

OUTSIDE AIR DUCT - EXISTING

RETURN AIR DUCT - NEW

RETURN AIR DUCT - DEMO

RETURN AIR DUCT - EXISTING

SUPPLY AIR DUCT - NEW

SUPPLY AIR DUCT - DEMO

SUPPLY AIR DUCT - EXISTING

FILE NO.: 751 / 17107.RAA

INDEX NO.: 86350

STATE OF MICHIGAN

DEPARTMENT OF TECHNOLOGY, MANAGEMENT AND BUDGET

FACILITIES AND BUSINESS SERVICES ADMINISTRATION

DESIGN AND CONSTRUCTION DIVISION

ROBERT C. HALL, RA, NCARB, DIRECTOR

ENGINEERING

ARCHITECTURE

PLANNING

SURVEYING

ENVIRONMENTAL

PROJECT TITLE:

OWNER:

PROJECT LOCATION:

PROJECT NO:

DRAWN BY:

CHECKED:

APPROVED:

1 2 3 4 5

1 2 3 4 5

D

C

B

A

D

C

B

A

© U.P. Engineers & Architects, Inc.

DESIGNED BY:

DATE:ISSUED FOR:

100 PORTAGE STREET

HOUGHTON, MI 49931

(906) 482-4810

424 SOUTH PINE STREET

ISHPEMING, MI 49849

(906) 485-1011

707 ASHMUN ST.

SAULT STE. MARIE, MI 49783

(906) 635-0511

1701 DUNLAP AVE. SUITE B

MARINETTE, WI 54143

(715) 732-4188

2906 N. STEPHENSON AVE. SUITE 2

IRON MOUNTAIN, MI 49801

(906) 779-0937

P :\M

-1

D

TM

B -C on ve rt an

E x.

W or ks ho p bu ild in g\ D w gs

\M

-1

_W or ks ho p

B ld g.

rv t

1/

/2

1:

:4

P

M

MP001

MECHANICAL &

PLUMBING

ABBREVIATIONS,

SYMBOLS AND NOTES

CONVERT EXISTING

WORKSHOP BUILDING

MICH. DEPT. OF

TECHNOLOGY,

MANAGEMENT &

BUDGET

MEAD RD.

GLADSTONE, MI 49837

M12-17322

RMA

DWL

DWL

DWL

UP 2540 SF

STORAGE BAY

EQ

UA

L 1'

- 9

/4

0"

EQ

UA

L

GAS-FIRED INFRARED

HEATER VENT PIPE

M

IN

GAS-FIRED INFRARED HEATER,

SEE MECH. DWGS.

GAS-FIRED INFRARED HEATER

INTAKE VENT

ALIGN INFRARED

HEATERS

ALIGN INFRARED

HEATERS

ROUTE VENT PIPE

TO AVOID EXISTING

6x6 COLUMN

NOTE: NO VEHICLES OVER 10' - 0".

MINIMUM CLEARANCES FROM HEATER

MUST BE MAINTAINED FROM VEHICLES

PARKED BELOW HEATER.

THE POSTING OF SIGNS MAY BE REQUIRED

IN STORAGE AREAS REFERRING TO

CLEARANCES TO THE HEATER.

REFER TO INFRARED HEATER OPERATION

MANUAL FOR MORE INFORMATION.

LP

3/4" LP1/2" LP1/2" LP

TO LP TANK

SECONDARY LP REGULATOR TO PROVIDE

11" W.C. SUPPLY PRESSURE TO BUILDING

AND UNDERGROUND PIPING TO LP TANK

FURNISHED AND INSTALLED BY LP GAS

PROVIDER.

MARK TUBE

LENGTH

INFRARED HEATER SCHEDULE

IR-1 20'

TYPE

TUBE

MBH

IN

STAGES

HEATING

VOLTS/

PH

120 / 1

MCA

MOCP

ELECTRICAL

COMB AIR

DIA

VENT DIA

4"

MANUF

CALCANA

MODEL

SR-40

GAS MAIN

GAS SUPPLY

SHUT-OFF VALVE

STAINLESS STEEL FLEX

CONNECTOR

REFLECTOR

BURNER BOX

ASSEMBLY

COUPLER

6" COMBUSTION

AIR INTAKE

NOTES:

1. SEAL ALL WALL PENETRATIONS.

2. INSTALL VENT / AIR PIPING WITHIN MANUFACTURER'S RECOMMEND

MAXIMUM LENGTHS, INCLUDING EQUIVALENT FITTING ALLOWANCES.

PITCH PER MFG. INSTRUCTION

. MAINTAIN CLEARANCE TO

COMBUSTIBLES IN

ACCORDANCE WITH

MANUFACTURER'S

RECOMMENDATIONS EXTERIOR WALL

WALL FLANGE ASSEMBLY

SIDEWALL

VENT CAP

18" MIN. 36

" M

IN

FROST LINE

1/2" GRAVEL FILL

DRAIN HOLE

3/4" WATER LINE

TY

P.

VALVE BODY

1" GALVANIZED PIPE

FINISHED GRADE

TY

P.

VACUUM BREAKER

ANTI-SIPHON

DEVICE

SYSTEM TYPE

DUCT AND EQUIPMENT INSULATION SCHEDULE

COMBUSTION AIR DUCT

TYPE

INSULATION OR

LINER THICKNESS

D-1 1-1/2"

DUCT

TYPE

DUCTWORK INSULATION TYPES

D-1

DESCRIPTION

ASTM C1290, TYPE III, FLEXIBLE GLASS FIBER,

COMMERCIAL GRADE WITH FACTORY APPLIED

REINFORCED FOIL JACKET MEETING ASTM

C1136, TYPE II, MAX. OPERATING TEMPERATURE:

250 DEG F, DENSITY: 1.5 LBS/CU FT.

MARK DESCRIPTION

PLUMBING FIXTURE SCHEDULE

YH-1

LIFT HANDLE WITH

LOCK, NON-FREEZE

YARD HYDRANT

MANUF.

WATTS

MODEL

HY-800

MATERIAL

EPOXY COATED

CAST IRON HEAD,

GALV. CASING,

BRONZE INTERNALS

OUTLET SIZE

3/4" MALE HOSE

OUTLET

REMARKS

MINIMUM 4 FOOT BURY, NON-FREEZE, w/ 18" DRAIN PORT.

PROVIDE HOSE CONNECTION VACUUM BREAKER EQUAL TO

"WATTS" MODEL LF8B TAMPER RESISTANT LEAD FREE TO

MEETING THE REQUIREMENTS OF ASSE 1011.

FILE NO.: 751 / 17107.RAA

INDEX NO.: 86350

STATE OF MICHIGAN

DEPARTMENT OF TECHNOLOGY, MANAGEMENT AND BUDGET

FACILITIES AND BUSINESS SERVICES ADMINISTRATION

DESIGN AND CONSTRUCTION DIVISION

ROBERT C. HALL, RA, NCARB, DIRECTOR

ENGINEERING

ARCHITECTURE

PLANNING

SURVEYING

ENVIRONMENTAL

PROJECT TITLE:

OWNER:

PROJECT LOCATION:

PROJECT NO:

DRAWN BY:

CHECKED:

APPROVED:

1 2 3 4 5

1 2 3 4 5

D

C

B

A

D

C

B

A

© U.P. Engineers & Architects, Inc.

DESIGNED BY:

DATE:ISSUED FOR:

100 PORTAGE STREET

HOUGHTON, MI 49931

(906) 482-4810

424 SOUTH PINE STREET

ISHPEMING, MI 49849

(906) 485-1011

707 ASHMUN ST.

SAULT STE. MARIE, MI 49783

(906) 635-0511

1701 DUNLAP AVE. SUITE B

MARINETTE, WI 54143

(715) 732-4188

2906 N. STEPHENSON AVE. SUITE 2

IRON MOUNTAIN, MI 49801

(906) 779-0937

P :\M

-1

D

TM

B -C on ve rt an

E x.

W or ks ho p bu ild in g\ D w gs

\M

-1

_W or ks ho p

B ld g.

rv t

1/

/2

1:

:4

P

M

MP101

MECHANICAL &

PLUMBING PLAN

CONVERT EXISTING

WORKSHOP BUILDING

MICH. DEPT. OF

TECHNOLOGY,

MANAGEMENT &

BUDGET

MEAD RD.

GLADSTONE, MI 49837

M12-17322

RMA

DWL

DWL

DWL

90% REVIEW 01/19/2018

1/4" = 1'-0"A1 MECHANICAL FLOOR PLAN

PROJECT

NORTH

TRUE

NORTH

NO SCALEC1

INFRARED HEATING SYSTEM - SIDEWALL

VENT / AIR DETAIL

NO SCALEC3 FREEZE-PROOF YARD HYDRANT

1. INSTALLATION SHALL BE IN ACCORDANCE WITH THE 2015 MICHIGAN PLUMBING CODE,

OR LATEST ADOPTED EDITION, ALL LOCAL CODES AND AUTHORITIES HAVING

JURISDICTION.

2. PLUMBING CONTRACTOR RESPONSIBLE FOR DOMESTIC WATER TO YARD HYDRANT.

3. DOMESTIC WATER PIPING BELOW GRADE SHALL BE:

A. DOMESTIC WATER PIPING BELOW GRADE SHALL BE TYPE "K" COPPER WITH

SIL-FOS SOLDERED JOINTS.

B. OR ASTM F877 NON-BARRIER PEX-A (NSF) EQUAL TO "UPONOR" AQUAPEX.

4. TEST NEW AND ALTERED EXISTING DOMESTIC WATER PIPING TO BE FREE OF LEAKS

BY SUBJECTING TO WATER AT WORKING PRESSURE OR BY AN AIR TEST OF 50 PSI

MINIMUM FOR 15 MINUTES. TEST SHALL BE WITNESSED BY THE CODE OFFICIAL AND

DOCUMENTED.

5. ALL FIXTURES AND EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE

MANUFACTURERS' RECOMMENDATIONS. ATTACH ALL FIXTURES TO SUPPORTING

SURFACES PLUMB AND LEVEL.

6. INSTALL POTABLE WATER CROSS CONNECTION PROTECTION DEVICES ON WATER

LINES WHERE CONTAMINATION OF DOMESTIC WATER MAY OCCUR (E.G.. HOSE BIBBS).

7. SANITIZE ALL NEW COLD WATER LINES AND EXISTING CONNECTIONS PER LOCAL

WATER DEPARTMENT REQUIREMENTS. FLUSH AND TEST SYSTEM FOR LEAKS.

8. PROVIDE ESCUTCHEON PLATES FOR ALL PIPES PASSING THROUGH WALLS, FLOORS

AND CEILINGS.

PLUMBING SPECIFICATIONS:

1. INSTALLATION SHALL BE IN ACCORDANCE WITH THE 2015 MICHIGAN MECHANICAL CODE, OR LATEST

ADOPTED EDITION, ALL LOCAL CODES AND AUTHORITIES HAVING JURISDICTION.

2. STEEL DUCTING SHALL BE ASTM A525 OR A527 GALVANIZED STEEL SHEET, LOCK-FORMING QUALITY, HAVING ZINC COATING OF 1.25 OZ. PER SQ. FT. FOR EACH SIDE IN CONFORMANCE WITH ASTM A90.

FABRICATE IN ACCORDANCE WITH SMACNA HVAC DUCT CONSTRUCTION STANDARDS - METAL AND

FLEXIBLE, AND NFPA 90 A, 90 B OR NFPA 96 AS REQUIRED.

3. INSTALL ALL DUCTWORK PER SMACNA STANDARDS. SEAL ALL TRANSVERSE JOINTS, SEAMS AND

CONNECTIONS OF COMBUSTION SUPPLY AIR DUCTS.

4. METAL DUCT SHALL BE SUPPORTED TO AVOID DEFLECTION IN DUCT.

5. GAS PIPING SIZES 2" AND UNDER SHALL BE ASTM A53/120, BLACK, SCH 40, T&C, WITH 150# MALLEABLE

IRON BLACK THREADED FITTINGS. THREADED JOINTS SHALL BE ASSEMBLED WITH "GASOILA"

COMPOUND. PROVIDE MAIN CUSTOMER SHUT OFF VALVE INSIDE BUILDING NEAREST BUILDING WALL PENETRATION. PROVIDE GAS SHUTOFF VALVE, DIRT LEG AND UNION AT EACH PIECE OF GAS FIRED EQUIPMENT. EXTERIOR GAS PIPING PIPING SHALL BE PRIMED AND PAINTED WITH TWO COATS OF EXTERIOR ENAMEL PAINT SUITABLE FOR METAL. COLOR SHALL MATCH NEARBY SURFACE. LABEL ALL

INTERIOR PIPING WITH PIPE TAPE MARKERS AS APPROVED PER ANSI STANDARDS.

6. PROVIDE APPROPRIATE CLEVIS HANGERS AND/OR SUPPORT STRUT AND CLAMPS, SIZED FOR GAS PIPING. PROVIDE FOR EXPANSION IN ALL PIPING THROUGH THE USE OF SWING JOINTS AND OFFSETS.

SUPPORT ALL PIPING IN ACCORDANCE WITH ASME B31.1.

7. GAS APPLIANCE VENTING MATERIAL AND INSTALLATION SHALL BE PER MANUFACTURERS

INSTRUCTIONS AND IN ACCORDANCE WITH THE MICHIGAN MECHANICAL AND THE INTERNATIONAL

FUEL GAS CODES.

8. DIRECT VENT, INTEGRAL VENT AND MECHANICAL DRAFT GAS APPLIANCES VENT SHALL TERMINATE A MINIMUM OF 10'-0" FROM LOT LINES OR ADJACENT BUILDINGS; 7'-0" MINIMUM ABOVE ADJACENT WALKWAY; 3'-0" MINIMUM ABOVE FORCED AIR INLETS LOCATED WITHIN 10'-0"; 4'-0" MINIMUM BELOW, 4'-0" HORIZONTALLY FROM, AND 1'-0" MINIMUM ABOVE ANY OPERABLE BUILDING OPENINGS OR GRAVITY INLETS; 3'-0" HORIZONTALLY FROM ANY PORTION OF THE ROOF STRUCTURE; NOT DIRECTLY ABOVE OR 3'-0" HORIZONTAL FROM A GAS REGULATOR; AND PER MANUFACTURERS INSTALLATION INSTRUCTIONS.

9. GAS APPLIANCE TYPE "B" VENT TERMINATIONS SHALL TERMINATE 2'-0" MINIMUM ABOVE THE ROOF PENETRATION; 3'-0" MINIMUM ABOVE FORCED AIR INLETS LOCATED WITHIN 10'-0"; AND SHALL

TERMINATE A MINIMUM OF 2-0" ABOVE ANY PORTION OF A BUILDING WITHIN 10'-0"; PER

MANUFACTURERS INSTALLATION INSTRUCTIONS.

10. ALL PENETRATIONS OF VENT/COMBUSTION AIR SYSTEMS THROUGH CEILINGS, FLOORS, WALLS AND

ROOFS SHALL BE PROPERLY FIRE STOPPED.

11. PROVIDE ESCUTCHEON PLATES FOR ALL PIPES AND FLASHINGS FOR DUCTS PASSING THROUGH

WALLS, FLOORS AND CEILINGS.

12. COMBUSTION AIR DUCT INSULATION: REFER TO INSULATION SCHEDULE.

MECHANICAL SPECIFICATIONS:

1. THESE DRAWINGS ARE DIAGRAMMATIC IN CHARACTER AND DO NOT NECESSARILY INDICATE EVERY

OFFSET, VALVE, FITTING ETC. REQUIRED. CONTRACTOR IS RESPONSIBLE FOR FIELD ROUTING ALL

DUCTWORK AND PIPING AT NO ADDITIONAL COST.

2. EXISTING CONDITIONS SHOWN ON THESE DRAWINGS HAVE BEEN OBTAINED FROM EXISTING

DRAWINGS AND / OR FIELD INSPECTIONS. CONTRACTOR SHALL FIELD VERIFY EXACT LOCATIONS AT TIME OF CONSTRUCTION. THIS DRAWING IS PART OF A SET OF DRAWINGS AND SPECIFICATIONS, AND

ALL SHALL BE USED AS A COMPLETE SET.

3. CONTRACTOR SHALL SECURE AND PAY FOR ANY AND ALL PERMITS AND INSPECTION FEES APPLICABLE TO THE WORK, AND PAY FOR ALL STATE AND FEDERAL TAXES IMPOSED. ALL TAXES FOR MATERIALS AND EQUIPMENT THAT ARE PERMANENTLY INSTALLED SHALL BE INCLUDED AS A LINE ITEM ON THE BID FORM.

4. VERIFY ALL LAYOUTS, DIMENSIONS, CLEARANCES, AND METHODS WITH EQUIPMENT SUPPLIERS AND ALL

TRADES. COORDINATE WITH OWNER FOR REQUIREMENTS PERTAINING TO ALL OWNER FURNISHED

EQUIPMENT.

5. CONTRACTOR SHALL BE RESPONSIBLE FOR PROJECT COORDINATION WITH OTHER TRADES AND

SUPERVISION OF THEIR OWN SUB-CONTRACTORS.

6. CONTRACTORS SHALL SUBMIT, REVIEW, AND COORDINATE ALL EXISTING BUILDING SHUTDOWNS WITH

OWNER PRIOR TO SCHEDULING AND OPERATIONS.

7. EACH CONTRACTOR SHALL PERFORM ALL CUTTING AND PATCHING NECESSARY FOR INSTALLATION OF THEIR WORK. CONTRACTORS SHALL REPAIR/PATCH ALL AREAS DISTURBED DURING DEMOLITION AND INSTALLATION TO MATCH SURROUNDING AREAS. MAINTAIN ALL FIRE RATED ASSEMBLY CONSTRUCTION WHEN APPLICABLE. CUTTING AND PATCHING NECESSARY TO EXPOSE DEFECTIVE WORK FOR REPAIR

WILL BE DONE AT THE CONTRACTORS EXPENSE.

8. PROVIDE ALL PENETRATIONS, FLASHING AND SEALING, MAKE OPENINGS WEATHER TIGHT. IT IS THE RESPONSIBILITY OF THIS CONTRACTOR TO COORDINATE ALL EQUIPMENT BUILDING OPENINGS WITH THE

GENERAL CONTRACTOR.

9. PLANS AND SPECIFICATIONS ARE INTENDED TO CONFORM TO GOVERNING CODES AND STANDARDS. IF

NON-CONFORMITIES ARE DISCOVERED, BRING SAME TO THE ATTENTION OF THE ENGINEER FOR

CLARIFICATION BEFORE SUBMITTING BID OR PROCEEDING WITH WORK. CODE COMPLIANCE OF WORK

INSTALLED WITHOUT SUCH CONSULTATION WILL BE THE CONTRACTORS RESPONSIBILITY.

10. CONTRACTOR SHALL MAKE PROVISIONS FOR FUTURE LP GAS SERVICE INSTALLATION BY THE OWNER.

THE OWNER SHALL PAY ALL SERVICE FEES AND CHARGES, INCLUDING TANKS, SERVICE PIPING UPSTREAM OF THE SECONDARY REGULATOR, REGULATOR(S), REQUIRED BY LP GAS COMPANY FOR NEW LP GAS SERVICE. CONTRACTOR SHALL INSTALL PIPING FOR AND SECURE AND PAY FOR ANY AND ALL PERMITS AND INSPECTION FEES REQUIRED DOWNSTREAM OF THE BUILDING MOUNTED SECONDARY

REGULATOR BY THE LP GAS PROVIDER.

11. INSTALLATION SHALL BE IN ACCORDANCE WITH THE 2015 MICHIGAN MECHANICAL CODE, 2015 PLUMBING CODE, MICHIGAN PART 8 & 2014 NATIONAL ELECTRICAL CODES, OR LATEST ADOPTED

EDITION, ALL LOCAL CODES AND AUTHORITIES HAVING JURISDICTION.

12. REFER TO ARCHITECTURAL SHEETS FOR FLOOR PLANS AND SECTIONS AS REQUIRED TO DETERMINE

ROUTING REQUIREMENTS AND POTENTIAL CONFLICTS.

13. CONTRACTORS SHALL COORDINATE WITH ALL OTHER TRADES FOR INSTALLATION OF ALL EQUIPMENT.

CONTRACTORS SHALL FIELD VERIFY EXISTING CONDITIONS. PREPARE COORDINATION DRAWINGS AT A

MINIMUM OF 1/2" = 1'-0" SCALE WHERE ACCURATE COORDINATION IS REQUIRED.

14. MANUFACTURERS MODEL NUMBERS LISTED ON DRAWINGS ARE BASIS FOR DESIGN. CONTRACTOR MAY SUBMIT AN "APPROVED EQUAL" FOR REVIEW BY THE ENGINEER. REFER TO GENERAL CONDITIONS FOR PROCEDURES TO FOLLOW FOR SUBSTITUTIONS. DESIGNATION OF AN "APPROVED EQUAL" IS OF THE

ENGINEER'S DISCRETION.

15. IF EQUIPMENT OTHER THAN AS SPECIFIED IN THESE BID DOCUMENTS IS PROVIDED, THE CONTRACTOR FURNISHING THE EQUIPMENT IS RESPONSIBLE FOR THE IMPACT OF ANY REDESIGN AND INSTALLATION COSTS, INCLUDING BUT NOT LIMITED TO: STRUCTURE, FOUNDATIONS, ENVIRONMENTAL, UTILITIES, PIPING, DUCTWORK, WIRING, DEVICES, OWNERS FURNISHED EQUIPMENT, ETC.. REDESIGN SHALL BE

SUBJECT TO THE APPROVAL OF THE OWNER, ARCHITECT & ENGINEER.

16. MATERIALS, VALVES, EQUIPMENT AND FIXTURES SHALL BE INSTALLED IN ACCORDANCE WITH THE

MANUFACTURERS' RECOMMENDATIONS. CONNECTIONS TO FIXTURES, DEVICES AND EQUIPMENT

SHALL BE VERIFIED WITH MANUFACTURER'S CERTIFIED DRAWINGS.

17. FINAL LOCATION OF ALL CEILING INFRARED HEATERS, ACCESSORIES, DEVICES, ETC. SHALL BE INSTALLED PER REFLECTED CEILING PLAN AND LOCATED CONSISTENT WITH CEILING AS INSTALLED.

18. PROVIDE DIELECTRIC UNIONS AT ALL JUNCTIONS OF DISSIMILAR METALS.

19. INSTALL PIPING TO ALLOW FOR EXPANSION AND CONTRACTION WITHOUT STRESSING PIPE, JOINTS, OR

CONNECTED EQUIPMENT.

20. PROVIDE ALL VALVING FOR THE PROPER SECTIONALIZING, ZONING AND OPERATION OF PIPING

SYSTEMS.

21. PENETRATIONS OF FLOOR/CEILING ASSEMBLIES AND ASSEMBLIES REQUIRED TO HAVE A FIRE- RESISTANCE RATING SHALL BE PROTECTED IN ACCORDANCE WITH THE INTERNATIONAL BUILDING

CODE.

22. PROVIDE PIPE TAPE MARKERS, CONFORMING TO ANSI AND ASME A13.1 STANDARDS. MINIMUM IDENTITY OF PIPING CONVEYING GAS OR FLUID WITH FLOW DIRECTION ARROWS AROUND ENTIRE DIAMETER COVERING BOTH ENDS OF PIPE LABEL. INTERVAL OF LABEL SPACING SHALL NOT EXCEED 25 FEET.

23. SUBMIT FOR REVIEW CERTIFIED EQUIPMENT DRAWINGS AND/OR SUBMITTALS TO THE ARCHITECT / ENGINEER FOR APPROVAL OFINFRARED HEATERS, YARD HYDRANT, CONTROLS, ETC.. ARCHITECT /

ENGINEER REVIEW OF SHOP DRAWINGS, PRODUCT DATA OR SAMPLES DOES NOT RELIEVE THE

CONTRACTOR FROM COMPLYING WITH REQUIREMENTS OF THE CONTRACT DOCUMENTS.

24. PROVIDE OPERATION AND MAINTENANCE MANUAL PRIOR TO PROJECT COMPLETION TO ENGINEER FOR REVIEW. THE MANUAL SHALL CONSIST OF, AT A MINIMUM; REVIEWED EQUIPMENT DRAWINGS AND/OR SUBMITTALS WITH COLOR SAMPLES (IF APPLICABLE), AND OPERATING & MAINTENANCE MANUALS. THE MANUAL SHALL ALSO CONTAIN INSPECTION AND TESTING REPORTS, COPY OF OWNERS TRAINING ATTENDANCE SHEET, M.S.D.S. INFORMATION FOR MATERIALS LEFT ON THE PROJECT LOCATION, AS- BUILT DRAWINGS MARKED IN RED, CONTROLS DIAGRAMS, PREVENTIVE MAINTENANCE CHECKLIST, PARTS LISTS AND PRODUCT WARRANTY INFORMATION.

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .