Plan_Set.pdf
PDF 27 MB Posted
- Solicitation number
- 2024-22B
- Issued by
- Fort Bend County, Round Mountain Town, Texas
About this file
The document is a comprehensive Plan Set for a Traffic Signalization Project prepared by MBCO Engineering, LLC for the City of Rosenberg in Fort Bend County, Texas. The project involves installing a traffic signal at the intersection of Plaza Drive and Commercial Drive, with engineering job number 1-0127-2301. The plan set includes detailed drawings and specifications for traffic signal installation, featuring eight signal poles, vehicle and pedestrian signal heads, conduit routing, paving improvements, and pavement markings. The project will involve constructing ADA-compliant curb ramps, removing and relocating existing signs, and implementing new traffic control infrastructure.
The estimated project budget is $400,000, with the work to be performed according to City of Rosenberg and Texas Department of Transportation (TxDOT) requirements. The project specifications mandate black-housing vehicle signals with LED lamp units, Diamond Grade retroreflective signage, and specific grounding and installation standards. Key technical requirements include installing VIVDS detection systems, setting signal heads at a minimum of 17.5 feet above the roadway, and following precise electrical and construction guidelines. The project documents indicate careful consideration of existing utilities, with specific instructions for contractors to locate and protect underground infrastructure during construction.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
No
Dr aw n Ch k'd De sc rip tio n
TRAFFIC SIGNALIZATION
TO SERVE THE INTERSECTION OF
PLAZA DRIVE AT COMMERCIAL DRIVE
CITY OF ROSENBERG, FORT BEND COUNTY, TEXAS
April 2024
I, BONNIE C. MOSS, HEREBY ACKNOWLEDGE THAT I HAVE REVIEWED THE FLOOD HAZARD
RECOVERY DATA AND USED THE MOST RESTRICTIVE INFORMATION FOR THE DESIGN OF THIS
PROJECT.
FIRM
FLOOD INSURANCE RATE MAP
PANEL 245 OF 575
MAP# 48157C0245L
MAP REVISED APRIL 2, 2014
BFE ELEVATION: N/A
THE SITE IN UNSHADED ZONE X, IS OUTSIDE 0.2% CHANCE FLOODPLAIN
CONSTRUCTION CONTRACTOR SHALL VERIFY ALL EXISTING UTILITY CROSSINGS PRIOR TO
START OF CONSTRUCTION AND NOTIFY ENGINEER OF RECORD IF ANY CONSTRUCTION
CONFLICTS EXIST. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DAMAGES TO
EXISTING UTILITIES RESULTING FROM CONSTRUCTION.
PROJECT
LOCATION
PROJECT
LOCATION
SHEET INDEX
SEE SHEET 2 FOR INDEX
93004 L I C E N S E D
P R
O F E S S I O N A L E N G I N E E R
STA TE OF TEX AS
BONNIE C. MOSS
VICINITY MAP
N.T.S.
KEY MAP: 605V
ZIP CODE: 77471
AREA MAP
N.T.S.
KEY MAP: 605V
ZIP CODE: 77471
K:
\1
EN
G\
Ci ty o f R os en be rg
_0
7\ 1-
-2
1_ Pl az a
Dr
C om m er ci al
D r S ig na l\0 7.
_C
AD
\0
7.
_D ra w in gs \1
C
OV
ER
S
HE
ET
.d w g
Charles A. Kalkomey, P.E.
City Engineer
DATE
Executive Director of Public Services
THESE SIGNATURES ARE VOID IF CONSTRUCTION HAS NOT
BEEN COMMENCED IN ONE .(1) YEAR FROM DATE OF APPROVAL.
Rigo Calzoncin
DATE
1505 Highway 6 South, Suite 180 Houston, Texas 77077 281.760.1656 MBCOEngineering.com
SBE/WBE/DBE/HUB
TBPELS Engineering Firm No. F-16850 Land Surveying Firm No. 10194810
AutoCAD SHX Text
READING
AutoCAD SHX Text
HOMESTEAD
AutoCAD SHX Text Rabbs
AutoCAD SHX Text
AutoCAD SHX Text
READING
AutoCAD SHX Text
COMMERCIAL DR
AutoCAD SHX Text
PLAZA DR
AutoCAD SHX Text
VISTA DR
AutoCAD SHX Text
AutoCAD SHX Text
ALMEDA RD
AutoCAD SHX Text
BRAZOS RIVER
AutoCAD SHX Text
TEXAS
AutoCAD SHX Text
BUFFALO
AutoCAD SHX Text
WESTHEIMER RD
AutoCAD SHX Text
RICHMOND AVE
AutoCAD SHX Text
AutoCAD SHX Text
TEXAS
AutoCAD SHX Text
AutoCAD SHX Text
RESERVOIR
AutoCAD SHX Text
BARKER
AutoCAD SHX Text
AutoCAD SHX Text
BISSONETT
AutoCAD SHX Text 90A
AutoCAD SHX Text
AutoCAD SHX Text
BAYOU
AutoCAD SHX Text
GALVESTON BAY
AutoCAD SHX Text
TEXAS
AutoCAD SHX Text
FAIRMONT PKWY
AutoCAD SHX Text
HOUSTON SHIP CHANNEL
AutoCAD SHX Text
BELTWAY
AutoCAD SHX Text
ALMEDA-GENOA
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
TEXAS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
HARDY TOLL ROAD
AutoCAD SHX Text
CYPRESS CREEK
AutoCAD SHX Text
FM 1960
AutoCAD SHX Text
BELTWAY
AutoCAD SHX Text
LITTLE YORK
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
LAKE HOUSTON
AutoCAD SHX Text
HUMBLE-ATASCOSITA RD
AutoCAD SHX Text
MT. HOUSTON RD
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ELDRIDGE
AutoCAD SHX Text
AutoCAD SHX Text
TEXAS
AutoCAD SHX Text
TEXAS
AutoCAD SHX Text
AutoCAD SHX Text 90A
AutoCAD SHX Text
TX
AutoCAD SHX Text
AutoCAD SHX Text
TX
AutoCAD SHX Text
AutoCAD SHX Text
COUNTY
AutoCAD SHX Text
FT. BEND
AutoCAD SHX Text
COUNTY
AutoCAD SHX Text
MONTGOMERY
AutoCAD SHX Text
TEXAS
AutoCAD SHX Text
AutoCAD SHX Text
TEXAS
AutoCAD SHX Text
AutoCAD SHX Text
TEXAS
AutoCAD SHX Text
AutoCAD SHX Text
DAYTON
AutoCAD SHX Text
ROSENBERG
AutoCAD SHX Text
CYPRESS
AutoCAD SHX Text
BAYTOWN
AutoCAD SHX Text
SHELDON
AutoCAD SHX Text
HUMBLE
AutoCAD SHX Text
AutoCAD SHX Text
TEXAS
K:
\1
EN
G
\C ity o f R os en be rg
_0
7\ 1-
-2
1_ Pl az a
D r @
C om m er ci al
D r S ig na l\
.0 0_
C A
D \0
7.
_D ra w in gs \2
IN
D
EX
S
HE
ET
.d w g A pr
3, 4-
4:
pm
93004
L IC ENS EDPRO FES S IO NA L ENGIN
EER
STATE OF TEXAS
BONNIE C. MOSS
Drawn:
Sheet:
NAMEDATEREVISIONSNO. TRAFFIC SIGNAL INSTALLATION TO SERVE
PLAZA DRIVE AT COMMERCIAL DRIVE
Date:
Checked: Scale:
Job No.:
GG
SJ 1-0127-2301
1505 Highway 6 South, Suite 180 Houston, Texas 77077 281.760.1656 MBCOEngineering.com
SBE/WBE/DBE/HUB
TBPELS Engineering Firm No. F-16850 Land Surveying Firm No. 10194810
April 2024
INDEX SHEET
NTS 2 of 60
SHEET INDEX
SHEET
NO.
SHEET TITLE
1 COVER SHEET
2 INDEX SHEET
3 SUMMARY OF QUANTITIES
4 GENERAL NOTES (1 OF 4)
5 GENERAL NOTES (2 OF 4)
6 GENERAL NOTES (3 OF 4)
7 GENERAL NOTES (4 OF 4)
8 EXISTING CONDITIONS LAYOUT
9 TRAFFIC SIGNAL LAYOUT
10 TRAFFIC SIGNAL LAYOUT DETAILS
11 PAVING IMPROVEMENTS LAYOUT
12 PAVEMENT MARKING LAYOUT
13 TS-FD-12
14-15 SMA 100 (1-2)-12
16-20 LMA (1-5)-12
21 LUM -A-12
22 CFA-12
23 TS-BP-20
24 MA-D-12
25 MA-C-12
26 MA-DPD-20
27 CD/PMPS
28 OSNS/MD
29 SD/SCFD
30-41 ED (1-12)-14
42-45 PED-18
46-49 PM(1-4)-22
50 TSR(4)-13
51 SMD(GEN)-08
52-54 SMD (SLIP 1-3)-08
55-56 WZ (BTS 1-2)-13
57-58 TCP(1-3,1-4)-18
59-60
CITY OF ROSENBERG STANDARD
DETAILS
4/3/24
EN
G
\C ity o f R os en be rg
_0
7\ 1-
-2
1_ Pl az a
D r @
C om m er ci al
D r S ig na l\
.0 0_
C A
D \0
7.
_D ra w in gs \3
S
UM
M A
RY
O
F Q
UA
N
TIT
IE
S.
d w g
A pr
3, 4- 4:
EER
STATE OF TEXAS
BONNIE C. MOSS
Drawn:
Sheet:
NAMEDATEREVISIONSNO. TRAFFIC SIGNAL INSTALLATION TO SERVE
PLAZA DRIVE AT COMMERCIAL DRIVE
Date:
Checked: Scale:
Job No.:
GG
SJ 1-0127-2301
1505 Highway 6 South, Suite 180 Houston, Texas 77077 281.760.1656 MBCOEngineering.com
SBE/WBE/DBE/HUB
TBPELS Engineering Firm No. F-16850 Land Surveying Firm No. 10194810
April 2024
SUMMARY OF QUANTITIES
NTS 3 of 60
EN
G
\C ity o f R os en be rg
_0
7\ 1-
-2
1_ Pl az a
D r @
C om m er ci al
D r S ig na l\
.0 0_
C A
D \0
7.
_D ra w in gs \4
G
EN
ER
A
L N
O
TE
S (1
O F
4) .d w g
A pr
3, 4- 4:
EER
STATE OF TEXAS
BONNIE C. MOSS
Drawn:
Sheet:
NAMEDATEREVISIONSNO. TRAFFIC SIGNAL INSTALLATION TO SERVE
PLAZA DRIVE AT COMMERCIAL DRIVE
Date:
Checked: Scale:
Job No.:
GG
SJ 1-0127-2301
1505 Highway 6 South, Suite 180 Houston, Texas 77077 281.760.1656 MBCOEngineering.com
SBE/WBE/DBE/HUB
TBPELS Engineering Firm No. F-16850 Land Surveying Firm No. 10194810
April 2024
1. CITY OF ROSENBERG MUST BE INVITED TO THE PRE-CONSTRUCTION MEETING.
2. CONTRACTOR SHALL NOTIFY CITY OF ROSENBERG ENGINEERING DEPARTMENT 48 HOURS PRIOR TO COMMENCING CONSTRUCTION AND 48 HOUR NOTICE TO ANY CONSTRUCTION ACTIVITY WITHIN THE LIMITS OF THE PAVING.
3. CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL PERMITS REQUIRED FROM CITY OF ROSENBERG PRIOR TO
COMMENCING CONSTRUCTION OF ANY IMPROVEMENTS WITHIN CITY RIGHT OF WAYS.
4. ALL PAVING IMPROVEMENTS SHALL BE CONSTRUCTED IN ACCORDANCE WITH CITY OF ROSENBERG "RULES, REGULATIONS AND REQUIREMENTS" RELATING TO THE APPROVAL AND ACCEPTANCE OF IMPROVEMENTS IN
SUBDIVISIONS AS CURRENTLY AMENDED.
5. ALL ROAD WIDTHS, CURB RADII AND CURB ALIGNMENT SHOWN INDICATES BACK OF CURB
6. A CONTINUOUS LONGITUDINAL REINFORCING BAR SHALL BE USED IN THE CURBS.
7. ALL CONCRETE PAVEMENT SHALL BE 5 12 SACK CEMENT WITH A MINIMUM COMPRESSIVE STRENGTH OF 3500 PSI AT 28 DAYS. TRANSVERSE EXPANSION JOINTS SHALL BE INSTALLED AT EACH CURB RETURN AND AT A MAXIMUM
SPACING OF 60 FEET.
8. ALL WEATHER ACCESS TO ALL EXISTING STREETS AND DRIVEWAYS SHALL BE MAINTAINED AT ALL TIMES.
9. 4"X 12" REINFORCED CONCRETE CURB SHALL BE PLACED IN FRONT OF SINGLE FAMILY LOTS ONLY. ALL OTHER
AREAS SHALL BE 6" REINFORCED CONCRETE CURB.
10. AT ALL INTERSECTION LOCATIONS, TYPE 7 RAMPS SHALL BE PLACE IN ACCORDANCE WITH TXDOT PED-18 STANDARD DETAIL SHEET. A.D.A. - HANDICAP RAMPS SHALL BE INSTALLED WITH STREET PAVING AT ALL INTERSECTIONS AND COMPLY WITH CURRENT A.D.A. REGULATIONS UNLESS OTHERWISE SHOWN ON PLANS.
11. CURB HEADERS ARE REQUIRED AT CURB CONNECTIONS TO HANDICAP RAMPS, WITH NO CONSTRUCTION JOINT
WITHIN 5' OF RAMPS.
12. ALL INTERSECTIONS UTILIZING TRAFFIC CONTROL MEASURES SHALL HAVE A.D.A. WHEEL CHAIR RAMPS INSTALLED.
13. GUIDELINES ARE SET FORTH IN THE TEXAS "MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES", AS CURRENTLY AMENDED, SHALL BE OBSERVED. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ADEQUATE FLAGMEN, SIGNING, STRIPING AND WARNING DEVICES, ETC., DURING CONSTRUCTION - BOTH DAY AND NIGHT.
14. STREET NAME SIGNAGE SHALL BE ON A 18" HIGH SIGN FLAT BLADE W/REFLECTIVE GREEN BACKGROUND. STREET NAMES SHALL BE UPPER AND LOWERCASE LETTERING WITH UPPERCASE LETTERS OF 10" MINIMUM AND LOWERCASE LETTERS OF 4.5" MINIMUM. THE LETTERS SHALL BE REFLECTIVE WHITE. STREET NAME SIGNS SHALL
BE MOUNTED ON MAST ARM. BLOCK NUMBERS SHALL BE PLACED ON THE SIGNS.
15. A BLUE DOUBLE REFLECTORIZED BUTTON SHALL BE PLACED AT ALL FIRE HYDRANT LOCATIONS. THE BUTTON SHALL BE PLACED 12 INCHES OFF OF THE CENTERLINE OF THE STREET ON THE SAME SIDE AS THE HYDRANT.
16. THE PROJECT AND ALL PARTS THEREOF SHALL BE SUBJECT TO INSPECTION FROM TIME TO TIME BY INSPECTORS DESIGNATED BY CITY OF ROSENBERG. NO SUCH INSPECTIONS SHALL RELIEVE THE CONTRACTOR OF ANY OF ITS OBLIGATIONS HEREUNDER. NEITHER FAILURE TO INSPECT NOR FAILURE TO DISCOVER OR REJECT ANY OF THE WORK AS NOT IN ACCORDANCE WITH THE DRAWINGS AND SPECIFICATIONS, REQUIREMENTS, AND SPECIFICATIONS OF CITY OF ROSENBERG OR ANY PROVISION OF THIS PROJECT SHALL BE CONSTRUED TO IMPLY AN ACCEPTANCE OF SUCH WORK OR TO RELIEVE THE CONTRACTOR OF ANY OF ITS OBLIGATIONS HEREUNDER.
17. STABILIZED SUBGRADE: DETERMINE THE THICKNESS OF THE STABILIZED SUBGRADE AFTER CURING AND COMPACTION. IF THE SUBGRADE DEPTH IS GREATER THAN THE PROPOSED THICKNESS BY 20% OR MORE, THE CMT LAB MUST PROVIDE VERIFICATION THE PERCENTAGE OF MATERIAL BEING USED TO STABILIZE THE SUBGRADE
MEETS OR EXCEEDS PROJECT REQUIREMENTS. TEST RESULTS REQUIRED.
* CITY OF ROSENBERG NOTES SUPERSEDE ANY CONFLICTING NOTES.
GENERAL CONSTRUCTION NOTES
1. ALL TRAFFIC SIGNAL EQUIPMENT SHALL BE PER THE REQUIREMENTS OF CITY OF ROSENBERG AND TEXAS
DEPARTMENT OF TRANSPORTATION (TXDOT).
2. INSTALL SIGNS AND SIGNALS HORIZONTALLY ON MAST ARM MINIMUM OF 17 FT.-6 IN. ABOVE THE ROADWAY.
3. FURNISH BLACK HOUSING FOR VEHICLE SIGNALS WITH 12 IN. LENS AN BLACK BACK PLATES.
4. FURNISH VEHICLE SIGNALS WITH LIGHT EMITTING DIODE (LED) SIGNAL LAMP UNITS.
5. USE DIAMOND GRADE RETROREFLECTIVE SHEETING FOR SIGNS MOUNTED UNDER OR ADJACENT TO THE SIGNAL
HEADS.
6. LOCATE CONTROLLERS, STEEL POLES, DETECTION ZONES AS APPROVED BY CITY OF ROSENBERG IN THE FIELD.
7. REPAIR OR REPLACE PAVEMENT AND SIDEWALKS DAMAGED BY THE CONTRACTOR'S FORCES DURING
CONSTRUCTION AT NO COST TO THE CITY OF ROSENBERG.
8. FURNISH AND INSTALL DUCT SEAL TO ENCLOSE THE ENDS OF EACH CONDUIT CONTAINING SIGNAL CABLE.
9. THE CONTRACTOR SHALL INSTALL A CLOSED NIPPLE WITH LOCK NUT AND BUSHING (SIZE AS REQUIRED) TO PREVENT ABRASION TO SIGNAL CABLE WHERE THE CABLE ENTERS THE UPPER PORTION OF THE SIGNAL POLE.
10. DO NOT PLACE SIGNAL HEADS OVER THE ROADWAY UNTIL ALL NECESSARY MATERIALS ARE ON HAND AS
APPROVED.
11. INSTALL TWO SET SCREWS ON ALL VEHICLE SIGNAL HEAD MOUNTING HARDWARE FITTINGS.
12. WRAP SIGNAL HEADS WITH DARK PLASTIC OR SUITABLE MATERIAL TO CONCEAL THE SIGNAL FACES FROM THE
ITEM OF INSTALLATION UNTIL PLACING INTO OPERATION. DO NOT USE BURLAP.
13. FURNISH AND INSTALL VIVDS DETECTION SYSTEM, COMPATIBLE MOUNTS, ALL CABLES (AS RECOMMENDED BY ECONOLITE), MODULES, AND ALL NECESSARY EQUIPMENT FOR A COMPLETE FUNCTIONAL VIVDS DETECTION
SYSTEM INCLUDING SOFTWARE AND ANY UPLOAD/DOWNLOAD PROGRAMMING DEVICE.
14. WORK IN THE CONTROLLER CABINET SHALL INCLUDE INSTALLING THE EQUIPMENT AND PERFORMING THE WORK
NECESSARY TO CONNECT AND OPERATE THE DETECTION SYSTEM AT THE INTERSECTION.
15. THE CONTRACTOR SHALL FOLLOW MANUFACTURER SPECIFICATIONS DETECTION SYSTEM INSTALLATION.
16. INSTALL A 5/8IN. (MINIMUM) EYE BOLT FOR THE POINT OF ATTACHMENT BELOW THE SERVICE ENTRANCE
WEATHERHEAD FOR THE SERVICE DROP (120/240 VOLT SERVICE) TO STEEL POLE.
17. GROUND STEEL MAST ARM POLE ASSEMBLIES IN ACCORDANCE WITH REQUIREMENTS SHOWN ON THE LATEST TXDOT TRAFFIC SIGNAL POLE FOUNDATION STANDARD. USE THE GROUNDING LUG ON THE POLE TO GROUND THE
POLE TO THE GROUND CONDUCTORS FROM THE CONDUITS.
18. VERIFY THE CORRECT MAST ARM POLE LENGTHS FOR THIS SIGNALIZED INTERSECTION PRIOR TO ORDERING THE
EQUIPMENT.
19. MBCO ENGINEERING, LLC WILL PROVIDE PHASING AND TIMINGS FOR PERMANENT TRAFFIC SIGNALS.
20. EXISTING STOP SIGNS AT THE INTERSECTION SHALL BE REMOVED AND DISPOSED OF PROPERLY.
21. ALL TRAFFIC SIGNAL POLE FOUNDATION LOCATIONS SHALL BE APPROVED BY THE ENGINEER OR REPRESENTATIVE
IN THE FIELD PRIOR TO DRILLING.
TRAFFIC SIGNAL GENERAL NOTES
GENERAL NOTES (1 OF 4)
NTS 4 of 60
EN
G
\C ity o f R os en be rg
_0
7\ 1-
-2
1_ Pl az a
D r @
C om m er ci al
D r S ig na l\
.0 0_
C A
D \0
7.
_D ra w in gs \5
G
EN
ER
A
L N
O
TE
S (2
O F
4) .d w g
A pr
3, 4- 4:
EER
STATE OF TEXAS
BONNIE C. MOSS
Drawn:
Sheet:
NAMEDATEREVISIONSNO. TRAFFIC SIGNAL INSTALLATION TO SERVE
PLAZA DRIVE AT COMMERCIAL DRIVE
Date:
Checked: Scale:
Job No.:
GG
SJ 1-0127-2301
1505 Highway 6 South, Suite 180 Houston, Texas 77077 281.760.1656 MBCOEngineering.com
SBE/WBE/DBE/HUB
TBPELS Engineering Firm No. F-16850 Land Surveying Firm No. 10194810
April 2024
FOR ROADWAY ILLUMINATION AND ELECTRICAL ITEMS, USE MATERIALS FROM PRE-QUALIFIED PRODUCERS AS SHOWN ON THE CONSTRUCTION DIVISION (CST) OF THE DEPARTMENT'S MATERIAL PRODUCERS LIST. CHECK THE LATEST LINK ON THE DEPARTMENT'S WEBSITE FOR THIS LIST. THE CATEGORY/ITEM IS “ROADWAY ILLUMINATION AND ELECTRICAL
SUPPLIES.” NO SUBSTITUTIONS WILL BE ALLOWED FOR MATERIALS FOUND ON THIS LIST.
PERFORM ELECTRICAL WORK IN CONFORMANCE WITH THE NATIONAL ELECTRICAL CODE (NEC) AND THE
DEPARTMENT'S STANDARD SHEETS.
THE CONTRACTOR MAY MAKE THE ELECTRICAL GROUNDING CONNECTIONS AND PERMISSIBLE SPLICES USING THE THERMAL FUSION PROCESS, CADWELD, THERMOWELD, OR APPROVED EQUAL, INSTEAD OF BOLTED CONNECTIONS
AND SPLICES.
THE CITY'S ELECTRICAL DIVISION PERSONNEL WILL ALSO INSPECT LIGHTING SYSTEMS WITHIN THE CITY LIMITS.
PORTIONS OF THE WORK FOUND TO BE DEFICIENT DURING THIS INSPECTION WILL NOT BE ACCEPTED.
GENERAL: ROADWAY ILLUMINATION AND ELECTRICAL
MARK STATIONS EVERY 100 FT. AND MAINTAIN THE MARKINGS FOR THE PROJECT DURATION. REMOVE THE STATION MARKINGS AT THE COMPLETION OF THE PROJECT. THIS WORK IS SUBSIDIARY TO THE VARIOUS BID ITEMS.
DO NOT MIX OR STORE MATERIALS, OR STORE OR REPAIR EQUIPMENT, ON TOP OF CONCRETE PAVEMENT OR BRIDGE DECKS UNLESS AUTHORIZED BY THE ENGINEER. PERMISSION WILL BE GRANTED TO STORE MATERIALS ON SURFACES
IF NO DAMAGE OR DISCOLORATION WILL RESULT.
PERSONAL VEHICLES OF EMPLOYEES ARE NOT PERMITTED TO PARK WITHIN THE RIGHT OF WAY, INCLUDING SECTIONS CLOSED TO PUBLIC TRAFFIC. EMPLOYEES MAY PARK ON THE RIGHT OF WAY AT THE CONTRACTOR'S OFFICE, EQUIPMENT, AND MATERIALS STORAGE YARD SITES.
ASSUME OWNERSHIP OF DEBRIS AND DISPOSE OF AT AN APPROVED LOCATION. DO NOT DISPOSE OF DEBRIS ON
PRIVATE PROPERTY UNLESS APPROVED IN WRITING BY THE ENGINEER.
CONTROL THE DUST CAUSED BY CONSTRUCTION OPERATIONS. FOR SWEEPING THE BASE MATERIAL IN PREPARATION FOR LAYING ASPHALT AND FOR SWEEPING THE FINISHED CONCRETE PAVEMENT, USE ONE OF THE FOLLOWING TYPES
OF SWEEPERS OR APPROVED EQUAL:
TRICYCLE TYPE - WAYNE SERIES 900, ELGIN WHITE WING, ELGIN PELICAN
TRUCK TYPE - 4 WHEEL - M-B CRUISER II, WAYNE MODEL 945, MOBILE TE-3, MOBILE TE-4, MURPHY 4042
GENERAL: SITE MANAGEMENT
SCHEDULE CONSTRUCTION OPERATIONS SUCH THAT PREPARING INDIVIDUAL ITEMS OF WORK FOLLOWS IN CLOSE SEQUENCE TO CONSTRUCTING STORM DRAINS IN ORDER TO PROVIDE AS LITTLE INCONVENIENCE AS PRACTICAL TO
THE BUSINESSES AND RESIDENTS ALONG THE PROJECT.
GENERAL: TRAFFIC CONTROL AND CONSTRUCTION
CONSIDER THE LOCATIONS OF UNDERGROUND UTILITIES DEPICTED IN THE PLANS AS APPROXIMATE AND EMPLOY RESPONSIBLE CARE TO AVOID DAMAGING UTILITY FACILITIES. DEPENDING UPON SCOPE AND MAGNITUDE OF PLANNED CONSTRUCTION ACTIVITIES, ADVANCED FIELD CONFIRMATION BY THE UTILITY OWNER OR OPERATOR MAY BE PRUDENT. WHERE POSSIBLE, PROTECT AND PRESERVE PERMANENT SIGNS, MARKERS, AND DESIGNATIONS OF
UNDERGROUND FACILITIES.
IF THE CONTRACTOR DAMAGES OR CAUSES DAMAGE (BREAKS, LEAKS, NICKS, DENTS, GOUGES, ETC.) TO THE UTILITY, CONTACT THE UTILITY FACILITY OWNER OR OPERATOR IMMEDIATELY.
NOTIFY THE ENGINEER AT LEAST 48 HOURS BEFORE CONSTRUCTING JUNCTION BOXES AT STORM DRAIN AND UTILITY
INTERSECTIONS.
INSTALL OR REMOVE POLES AND LUMINAIRES LOCATED NEAR OVERHEAD OR UNDERGROUND ELECTRICAL LINES USING ESTABLISHED INDUSTRY AND UTILITY SAFETY PRACTICES. CONSULT THE APPROPRIATE UTILITY COMPANY
BEFORE BEGINNING SUCH WORK.
IF OVERHEAD OR UNDERGROUND POWER LINES NEED TO BE DE-ENERGIZED, CONTACT THE ELECTRICAL SERVICE PROVIDER TO PERFORM THIS WORK. COSTS ASSOCIATED WITH DE-ENERGIZING THE POWER LINES OR OTHER
PROTECTIVE MEASURES REQUIRED ARE AT NO EXPENSE TO THE CITY OF ROSENBERG.
CONTRACTOR SHALL BE RESPONSIBLE FOR CONTACTING CENTERPOINT ENERGY TO LOCATE ALL CENTERPOINT
ENERGY FACILITIES.
GENERAL: UTILITIES
THIS PROJECT DOES NOT REQUIRE A U.S. ARMY CORPS OF ENGINEERS (USACE) SECTION 404 PERMIT BEFORE LETTING, BUT IF A PERMIT IS NEEDED DURING CONSTRUCTION, ASSUME RESPONSIBILITY FOR PREPARING THE PERMIT APPLICATION. SUBMIT THE PERMIT APPLICATION TO THE ENGINEER FOR APPROVAL. ONCE THE PERMIT APPLICATION IS APPROVED, SUBMIT IT TO THE USACE. ASSUME RESPONSIBILITY FOR THE REQUESTED REVISIONS, IN
COORDINATION WITH THE ENGINEER.
MAINTAIN THE ROADWAY SLOPE STABILITY. MAINTAINING SLOPE STABILITY IS SUBSIDIARY TO THE VARIOUS BID ITEMS.
NO SIGNIFICANT TRAFFIC GENERATOR EVENTS HAVE BEEN IDENTIFIED.
ITEM 7: LEGAL RELATIONS AND RESPONSIBILITIES
INCLUDE THE COST FOR FURNISHING AND INSTALLING ANCHOR BOLTS MOUNTED IN THE DRILLED SHAFTS IN THE UNIT
BID PRICE FOR THE VARIOUS DIAMETER DRILLED SHAFTS.
HAND EXCAVATION OR HYDRO-EXCAVATION AROUND THE PROPOSED TRAFFIC SIGNAL DRILLED SHAFT FOUNDATION MAY REQUIRED TO LOCATE UNDERGROUND UTILITIES AND CONFLICTS PRIOR TO INSTALLING DRILLED SHAFTS. THIS
WORK IS CONSIDERED INCIDENTAL TO THE PROJECT BID ITEMS.
THE DEPARTMENT MAY TEST USING ULTRASONIC METHODS THE ANCHOR BOLTS FOR OVERHEAD SIGN SUPPORTS, LIGHT STANDARDS, AND TRAFFIC SIGNAL POLES AFTER THEY ARE INSTALLED. REPLACE FAULTY ANCHOR BOLTS AS
DIRECTED. DO NOT WELD THE ANCHOR BOLTS.
ITEM 416: DRILLED SHAFT FOUNDATIONS
GENERAL NOTES (2 OF 4)
5 of 60NTS
IF WORKING NEAR POWER LINES, COMPLY WITH THE APPROPRIATE SECTIONS OF TEXAS STATE LAW AND FEDERAL
REGULATIONS RELATING TO THE TYPE OF WORK INVOLVED.
PERFORM ELECTRICAL WORK IN CONFORMANCE WITH THE NATIONAL ELECTRICAL CODE (NEC) AND DEPARTMENT'S
STANDARD SHEETS.
BEFORE BEGINNING ANY UNDERGROUND WORK, NOTIFY THE CITY OF ROSENBERG'S, PUBLIC WORKS DEPARTMENT, TO ESTABLISH THE LOCATIONS OF ANY EXISTING ELECTRICAL SYSTEMS FOR LIGHTING FACILITIES WITHIN THE LIMITS OF
THIS PROJECT.
EN
G
\C ity o f R os en be rg
_0
7\ 1-
-2
1_ Pl az a
D r @
C om m er ci al
D r S ig na l\
.0 0_
C A
D \0
7.
_D ra w in gs \6
G
EN
ER
A
L N
O
TE
S (3
O F
4) .d w g
A pr
3, 4- 4:
EER
STATE OF TEXAS
BONNIE C. MOSS
Drawn:
Sheet:
NAMEDATEREVISIONSNO. TRAFFIC SIGNAL INSTALLATION TO SERVE
PLAZA DRIVE AT COMMERCIAL DRIVE
Date:
Checked: Scale:
Job No.:
GG
SJ 1-0127-2301
1505 Highway 6 South, Suite 180 Houston, Texas 77077 281.760.1656 MBCOEngineering.com
SBE/WBE/DBE/HUB
TBPELS Engineering Firm No. F-16850 Land Surveying Firm No. 10194810
April 2024
USE A TRAFFIC CONTROL PLAN FOR HANDLING TRAFFIC THROUGH THE VARIOUS PHASES OF CONSTRUCTION.
FOLLOW THE PHASING SEQUENCE UNLESS OTHERWISE AGREED UPON BY THE CITY OF ROSENBERG ENGINEER AND THE PROJECT MANAGER. ENSURE THIS PLAN CONFORMS TO THE LATEST “TEXAS MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES” AND THE LATEST BARRICADE AND CONSTRUCTION (BC) STANDARD SHEETS. THE LATEST VERSIONS OF WORK ZONE STANDARD SHEETS WZ (BTS-1) AND WZ (BTS-2) ARE THE TRAFFIC CONTROL PLAN FOR THE
SIGNAL INSTALLATIONS.
SUBMIT CHANGES TO THE TRAFFIC CONTROL PLAN TO THE CITY OF ROSENBERG ENGINEER. PROVIDE A LAYOUT SHOWING THE CONSTRUCTION PHASING, SIGNS, STRIPING, AND SIGNALIZATIONS FOR CHANGES TO THE ORIGINAL
TRAFFIC CONTROL PLAN.
FURNISH AND MAINTAIN THE BARRICADES AND WARNING SIGNS, INCLUDING THE NECESSARY TEMPORARY AND PORTABLE TRAFFIC CONTROL DEVICES, DURING THE VARIOUS PHASES OF CONSTRUCTION. PLACE AND CONSTRUCT THESE BARRICADES AND WARNING SIGNS IN ACCORDANCE WITH THE LATEST “TEXAS MANUAL ON UNIFORM TRAFFIC
CONTROL DEVICES” FOR TYPICAL CONSTRUCTION LAYOUTS.
COVER WORK ZONE SIGNS WHEN WORK RELATED TO THE SIGNS IS NOT IN PROGRESS, OR WHEN ANY HAZARD
RELATED TO THE SIGNS NO LONGER EXISTS.
KEEP THE DELINEATION DEVICES, SIGNS, AND PAVEMENT MARKINGS CLEAN. THIS WORK IS SUBSIDIARY TO THE ITEM, “BARRICADES, SIGNS, AND TRAFFIC HANDLING.”
COVER OR REMOVE THE PERMANENT SIGNS AND CONSTRUCTION SIGNS THAT ARE INCORRECT OR THAT DO NOT
APPLY TO THE CURRENT SITUATION FOR A PARTICULAR PHASE.
USE TRAFFIC CONES FOR DAYTIME WORK ONLY. REPLACE THE CONES WITH PLASTIC DRUMS DURING NIGHTTIME
HOURS.
PLACE POSITIVE BARRIERS TO PROTECT DROP-OFF CONDITIONS GREATER THAN 2 FT. WITHIN THE CLEAR ZONE THAT
REMAIN OVERNIGHT.
DO NOT REDUCE THE EXISTING NUMBER OF LANES OPEN TO TRAFFIC EXCEPT AS SHOWN ON THE FOLLOWING TIME
SCHEDULE:
THE ABOVE TIMES ARE APPROVED FOR THE TRAFFIC CONTROL CONDITIONS LISTED. THE CITY OF ROSENBERG ENGINEER MAY APPROVE OTHER CLOSURE TIMES IF TRAFFIC COUNTS WARRANT. THE CITY OF ROSENBERG
ENGINEER MAY REDUCE THE ABOVE TIMES FOR SPECIAL EVENTS.
A MINIMUM OF 7 DAYS IN ADVANCE OF ANY TOTAL CLOSURE, PLACE A PORTABLE CHANGEABLE MESSAGE (PCM) SIGN AT THE LOCATION OF EACH TOTAL CLOSURE WHICH INFORMS THE TRAVELING PUBLIC OF THE DETAILS OF THE CLOSURE. ALTERNATELY, IF THE TRAFFIC CONTROL PLAN PROVIDES A POSITIVE BARRIER AT THE LOCATION, A NON-TRAILER MOUNTED STATIC MESSAGE BOARD SIGN BEHIND THE POSITIVE BARRIER MAY BE USED IN PLACE OF A
PCM.
ITEM 502: BARRICADES, SIGNS, AND TRAFFIC HANDLING
WHEN BACKFILLING BORE PITS, ENSURE THAT THE CONDUIT IS NOT DAMAGED DURING INSTALLATION OR DUE TO SETTLING BACKFILL MATERIAL. COMPACT SELECT BACKFILL IN 3 EQUAL LIFTS TO THE BOTTOM OF THE CONDUIT; OR IF USING SAND, PLACE IT 2 IN. ABOVE THE CONDUIT. ENSURE BACKFILL DENSITY IS EQUAL TO THAT OF THE EXISTING
SOIL. PREVENT MATERIAL FROM ENTERING THE CONDUIT.
CONSTRUCT BORE PITS A MINIMUM OF 5 FT. FROM THE EDGE OF THE BASE OR PAVEMENT. CLOSE THE BORE PIT
HOLES OVERNIGHT.
UNLESS OTHERWISE SHOWN ON THE PLANS, INSTALL UNDERGROUND CONDUIT A MINIMUM OF 24 IN. DEEP. INSTALL THE CONDUIT IN ACCORDANCE WITH THE LATEST NATIONAL ELECTRICAL CODE (NEC) AND APPLICABLE DEPARTMENT STANDARD SHEETS. PLACE CONDUIT UNDER DRIVEWAYS OR ROADWAYS A MINIMUM OF 24 IN. BELOW THE PAVEMENT
SURFACE.
IF USING CASING TO PLACE BORED CONDUIT, THE CASING IS SUBSIDIARY TO THE CONDUIT.
IF PLACING THE CONDUIT UNDER EXISTING PAVEMENT TO REACH THE SERVICE POLES, BORE THE CONDUIT IN PLACE AND EXTEND IT A MINIMUM DISTANCE OF 5 FT. BEYOND THE EDGE OF SHOULDER OR THE BACK OF CURB.
WHERE PVC, DUCT CABLE, AND HDPE CONDUIT 1 IN. AND LARGER IS ALLOWED AND INSTALLED PER DEPARTMENT STANDARDS, PROVIDE A PVC ELBOW IN PLACE OF THE GALVANIZED RIGID METAL ELBOW REQUIRED BY THE ELECTRICAL DETAILS STANDARDS. ENSURE THE PVC ELBOW IS OF THE SAME SCHEDULE RATING AS THE CONDUIT TO WHICH IT IS CONNECTED. USE ONLY A FLAT, HIGH TENSILE STRENGTH POLYESTER FIBER PULL TAPE TO PULL
CONDUCTORS THROUGH THE PVC CONDUIT SYSTEM.
ITEM 618: CONDUIT
TEST EACH WIRE OF EACH CABLE OR CONDUCTOR AFTER INSTALLATION. INCOMPLETE CIRCUITS OR DAMAGE TO THE WIRE OR THE CABLE ARE CAUSE FOR IMMEDIATE REJECTION OF THE ENTIRE CABLE BEING TESTED. REMOVE AND REPLACE THE ENTIRE CABLE AT NO EXPENSE TO THE CITY OF ROSENBERG. ALSO TEST THE REPLACEMENT CABLE
AFTER INSTALLATION.
WHEN PULLING CABLES OR CONDUCTORS THROUGH THE CONDUIT, DO NOT EXCEED THE MANUFACTURER'S RECOMMENDED PULLING TENSIONS. LUBRICATE THE CABLES OR CONDUCTORS WITH A LUBRICANT RECOMMENDED
BY THE CABLE MANUFACTURER.
ENSURE THAT CIRCUITS TEST CLEAR OF FAULTS, GROUNDS, AND OPEN CIRCUITS.
SPLIT BOLT CONNECTORS ARE ALLOWED ONLY FOR SPLICES ON THE GROUNDING CONDUCTORS.
FOR ROADSIDE FLASHING BEACON ASSEMBLIES (ITEM 685) AND PEDESTAL POLE ASSEMBLIES (ITEM 687) WITHIN THE PROJECT, PROVIDE SINGLE-POLE BREAKAWAY DISCONNECTS AS SHOWN ON THE CONSTRUCTION DIVISION (CST) MATERIAL PRODUCERS LIST. CHECK THE LATEST LINK ON THE DEPARTMENT'S WEBSITE FOR THIS LIST. THE CATEGORY IS “ROADWAY ILLUMINATION AND ELECTRICAL SUPPLIES.” THE FUSE HOLDER IS SHOWN ON THE LIST UNDER ITEM 685. FOR UNDERGROUND (HOT) CONDUCTORS, INSTALL A BREAKAWAY CONNECTOR WITH A DUMMY FUSE (SLUG). PROVIDE DUMMY FUSE (SLUG). FOR GROUNDED (NEUTRAL) CONDUCTORS, INSTALL A BREAKAWAY CONNECTOR WITH A WHITE COLORED MARKING AND A PERMANENTLY INSTALLED DUMMY FUSE (SLUG).
FOR ELECTRICAL LICENSING AND ELECTRICAL CERTIFICATION REQUIREMENTS FOR THIS PROJECT, SEE ITEM 7 OF THE
STANDARD SPECIFICATIONS AND ANY APPLICABLE SPECIAL PROVISIONS TO ITEM 7.
ITEM 620: ELECTRICAL CONDUCTORS
THE GROUND BOX LOCATIONS ARE APPROXIMATE. ALTERNATE GROUND BOX LOCATIONS MAY BE USED AS DIRECTED, TO AVOID PLACING IN SIDEWALKS OR DRIVEWAYS.
GROUND METAL GROUND BOX COVERS. BOND THE GROUND BOX COVER AND GROUND CONDUCTORS TO A GROUND
ROD LOCATED IN THE GROUND BOX AND TO THE SYSTEM GROUND.
GROUND THE EXISTING METAL GROUND BOX COVERS AS SHOWN ON THE LATEST STANDARD SHEET
ED (4)-14.
DURING CONSTRUCTION AND UNTIL PROJECT COMPLETION, PROVIDE PERSONNEL AND EQUIPMENT NECESSARY TO REMOVE GROUND BOX LIDS FOR INSPECTION. PROVIDE THIS ASSISTANCE WITHIN 24 HOURS OF NOTIFICATION.
CONSTRUCT CONCRETE APRONS IN ACCORDANCE WITH THE LATEST STANDARD SHEET ED (4)-14. MAKE THE DEPTH OF THE CONCRETE APRON THE SAME AS THE DEPTH OF THE GROUND BOX, EXCEPT FOR TYPE 1 AND TYPE 2 GROUND BOXES. FOR TYPE 1 OR TYPE 2 GROUND BOXES, CONSTRUCT THE CONCRETE APRON IN ACCORDANCE WITH DETAILS
SHOWN ON THE “GROUND BOX DETAILS INSTALLATIONS” STANDARD.
ITEM 624: GROUND BOXES
VERIFY AND COORDINATE THE ELECTRICAL SERVICE LOCATION WITH THE ENGINEERING SECTION OF THE
APPROPRIATE UTILITY DISTRICT OR COMPANY.
PROVIDE NUMERALS IN ACCORDANCE WITH CENTERPOINT REQUIREMENTS.
ITEM 628: ELECTRICAL SERVICES
GENERAL NOTES (3 OF 4)
6 of 60NTS
EN
G
\C ity o f R os en be rg
_0
7\ 1-
-2
1_ Pl az a
D r @
C om m er ci al
D r S ig na l\
.0 0_
C A
D \0
7.
_D ra w in gs \7
G
EN
ER
A
L N
O
TE
S (4
O F
4) .d w g
A pr
3, 4- 4:
EER
STATE OF TEXAS
BONNIE C. MOSS
Drawn:
Sheet:
NAMEDATEREVISIONSNO. TRAFFIC SIGNAL INSTALLATION TO SERVE
PLAZA DRIVE AT COMMERCIAL DRIVE
Date:
Checked: Scale:
Job No.:
GG
SJ 1-0127-2301
1505 Highway 6 South, Suite 180 Houston, Texas 77077 281.760.1656 MBCOEngineering.com
SBE/WBE/DBE/HUB
TBPELS Engineering Firm No. F-16850 Land Surveying Firm No. 10194810
April 2024
IF OTHER OPERATIONS ARE COMPLETE ON THE PROJECT AND IF THE CURING TIME PERIOD IS NOT YET ELAPSED, THE
CONTRACT TIME WILL BE SUSPENDED UNTIL THE CURING IS DONE.
BEFORE PLACING THE RAISED PAVEMENT MARKERS ON CONCRETE PAVEMENT, BLAST CLEAN THE SURFACE USING AN ABRASIVE-BLASTING MEDIUM. THIS WORK IS SUBSIDIARY TO THE ITEM, “RAISED PAVEMENT MARKERS.”
PROVIDE EPOXY ADHESIVE THAT IS MACHINE-MIXED OR NOZZLE-MIXED AND DISPENSED. EQUIP THE MACHINE OR
NOZZLE WITH A MECHANISM TO ENSURE POSITIVE MIX MEASUREMENT CONTROL.
ITEM 672: RAISED PAVEMENT MARKERS
CLEARLY MARK OR HIGHLIGHT ON THE SHOP DRAWINGS THE ITEMS BEING FURNISHED FOR THIS PROJECT.
FURNISH LABOR, TOOLS, EQUIPMENT, AND MATERIALS AS SHOWN ON THE PLANS AND SPECIFICATIONS FOR A
COMPLETE AND OPERATING SIGNAL INSTALLATION.
FURNISH THE TYPE OF CONTROLLER CABINET SPECIFIED ON THE PLANS, PER CITY OF ROSENBERG APPROVED
EQUIPMENT LIST.
PROVIDE A FULL-TIME QUALIFIED TRAFFIC SIGNAL TECHNICIAN RESPONSIBLE FOR INSTALLING, MAINTAINING, OR
REPLACING TRAFFIC SIGNAL DEVICES.
MAKE ADJUSTMENTS IN PROJECT CONSTRUCTION, IF NEEDED, DUE TO CONFLICTS WITH UNDERGROUND UTILITIES.
DO NOT AIM THE LUMINAIRE ARMS MOUNTED ON TRAFFIC SIGNAL POLES INTO THE INTERSECTION. AIM EACH ARM PERPENDICULAR TO THE CENTERLINE OF THE ROADWAY IT IS INTENDED TO COVER, TO DEVELOP THE PROPER
ILLUMINATION PATTERN FOR THE INTERSECTION.
ALLOW THE ELECTRICAL WORK TO BE INSPECTED BY THE CITY. COMPLYING WITH THE PROVISIONS AND REQUIREMENTS OF THE CITY ELECTRICAL ORDINANCE IS NOT REQUIRED. SUCH INSPECTION DOES NOT MAKE THE
CITY A PARTY TO THIS CONTRACT.
PROVIDE CONTINUOUS CONDUCTORS WITHOUT SPLICES FROM SIGNAL CONTROLLER TO SIGNAL HEADS. ROUTE THE CONDUCTORS FOR LUMINAIRES TO THE SERVICE ENCLOSURE. SPLICES OR ATTACHMENTS TO THE TERMINAL BLOCK IN THE ACCESS COMPARTMENT OF THE MAST ARM POLE ARE NOT PERMITTED EXCEPT FOR THE LUMINAIRE CABLE.
ABRASIONS TO THE CONDUCTOR INSULATION CAUSED WHILE PULLING CABLE FOR THE TRAFFIC SIGNAL SYSTEM ARE CAUSE FOR IMMEDIATE REJECTION. REMOVE AND REPLACE THE ENTIRE DAMAGED CABLE AT NO EXPENSE TO THE
CITY OF ROSENBERG.
WHEN PULLING CABLES OR CONDUCTORS THROUGH CONDUIT, DO NOT EXCEED THE MANUFACTURER'S RECOMMENDED PULLING TENSIONS. LUBRICATE THE CABLES OR CONDUCTORS WITH A LUBRICANT AS
RECOMMENDED BY THE CABLE MANUFACTURER.
BOND THE CONTROLLER HOUSING, SIGNAL POLES, CONDUIT, AND SPANS TO A MINIMUM NO. 6 AWG STRANDED COPPER CONDUCTOR. AN EQUIPMENT GROUNDING CONDUCTOR IS REQUIRED IN EVERY CONDUIT TO FORM A CONTINUOUS GROUNDING SYSTEM. EFFECTIVELY CONNECT THE GROUNDING SYSTEM TO GROUND RODS OR
CONCRETE ENCASED GROUNDING ELECTRODES AS INDICATED IN THE PLANS.
WRAP TRAFFIC AND PEDESTRIAN SIGNAL HEADS WITH DARK PLASTIC OR SUITABLE MATERIAL TO CONCEAL THE SIGNAL FACES FROM THE TIME OF INSTALLATION UNTIL PLACING INTO OPERATION. DO NOT USE BURLAP.
FURNISH SIGNAL HEADS FROM THE SAME MANUFACTURER, PER CITY OF ROSENBERG APPROVED EQUIPMENT LIST
USE TYPE C HIGH SPECIFIC INTENSITY GRADE SHEETING FOR SIGNS MOUNTED UNDER OR ADJACENT TO THE SIGNAL
HEADS.
FURNISH AND ATTACH COMPRESSION TYPE CONNECTORS. INSTALL THE CONNECTORS WITH A COMPRESSION MECHANICAL RELEASE HAND-CRIMPING TOOL TO EACH INDIVIDUAL CONDUCTOR BEFORE MAKING CONNECTIONS TO
THE TERMINAL STRIPS.
THE STANDARD 4.5-IN. GALVANIZED PIPE TYPE POLES, EXCEPT THE BREAKAWAY TYPE, ARE SUBJECT ONLY TO THE ENGINEER'S INSPECTION FOR THEIR ACCEPTANCE. MILL TEST REPORTS OR DOCUMENTATION WILL NOT BE REQUIRED.
ITEM 680: HIGHWAY TRAFFIC SIGNALS
INSTALL TWO SET SCREWS ON VEHICLE SIGNAL HEAD MOUNTING HARDWARE FITTINGS.
FURNISH BLACK HOUSINGS FOR VEHICLE AND PEDESTRIAN SIGNALS. ENSURE THE DOOR AND VISOR MATCH THE MAST ARM AND PEDESTRIAN POLE COLOR. FURNISH BLACK VEHICLE SIGNAL HEAD BACK PLATES.
ITEM 682: VEHICLE AND PEDESTRIAN SIGNAL HEADS
FOR A STEEL MAST ARM OR STEEL STRAIN POLE ASSEMBLY, HOLD THE ANCHOR BOLTS AND CONDUITS RIGIDLY IN
PLACE WITH A WELDED STEEL TEMPLATE.
USE A TEXAS CONE PENETROMETER READING OF 10. THE DRILLED SHAFT LENGTH IS FROM THE SURFACE ELEVATION TO THE BOTTOM OF THE DRILLED SHAFT. PROVIDE AN ADDITIONAL LENGTH OF THE POLE FOUNDATION FROM THE SURFACE LEVEL TO THE ROADWAY LEVEL, IF REQUIRED FOR UNUSUAL LOCATIONS. PROVIDE THE DRILLED SHAFT DEPTH REGARDLESS OF THE LENGTH OF THE POLE FOUNDATION. THE POLE FOUNDATION DEPTH FROM THE SURFACE
LEVEL TO THE ROADWAY LEVEL IS A MAXIMUM OF 4 FT., OR AS APPROVED.
LOCATE MAST ARM POLE ASSEMBLIES A MINIMUM OF 4 FT. FROM THE ROADWAY CURB OR PAVEMENT EDGE.
AFTER THE TRAFFIC SIGNAL POLE ASSEMBLY IS PLUMB AND THE NUTS ARE TIGHT, TACK-WELD EACH ANCHOR BOLT NUT IN TWO PLACES TO ITS WASHER. TACK-WELD EACH WASHER TO THE BASE PLATE IN TWO PLACES. DO NOT WELD COMPONENTS TO THE BOLT. PERFORM TACK-WELDING IN ACCORDANCE WITH THE ITEM, “STEEL STRUCTURES.”
AFTER TACK-WELDING, REPAIR GALVANIZING DAMAGE ON BOLTS, NUTS, AND WASHERS IN ACCORDANCE WITH
SECTION 445.3.5, “REPAIRS.”
THE DEPARTMENT MAY TEST THE ANCHOR BOLTS USING ULTRASONIC METHODS FOR TRAFFIC SIGNAL POLES AFTER THEY ARE INSTALLED. REPLACE FAULTY ANCHOR BOLTS AS DIRECTED. DO NOT WELD THE ANCHOR BOLTS.
FURNISH BLACK POWDER COATED TRAFFIC SIGNAL POLES. APPLY POWDER COATED FINISH OVER THE GALVANIZED SURFACE. PREPARE GALVANIZED SURFACES FOR POWDER COATING IN ACCORDANCE WITH THE POWDER COATING MANUFACTURER'S RECOMMENDATIONS. DO NOT WATER-QUENCH OR CHROMATE-QUENCH GALVANIZED SURFACES TO BE POWDER COATED. AFTER PREPARING GALVANIZED SURFACES, POWDER COAT WITH A MINIMUM OF 2.0 MILS DRY FILM THICKNESS (DFT) OF URETHANE POWDER OR TRIGLYCIDYL ISOCYANURATE (TGIC) POLYESTER POWDER.
PROVIDE POWDER COAT ADHESION MEETING THE 5A OR 5B CLASSIFICATIONS OF ASTM D3359. ENSURE POWDER
COATING IS UNIFORM IN APPEARANCE AND FREE OF SCRATCHES.
ITEM 686: TRAFFIC SIGNAL POLE ASSEMBLIES
FURNISH BLACK POWDER COATED PEDESTAL POLE ASSEMBLIES. APPLY POWDER COATED FINISH OVER THE GALVANIZED SURFACE. PREPARE GALVANIZED SURFACES FOR POWDER COATING IN ACCORDANCE WITH THE POWDER COATING MANUFACTURER'S RECOMMENDATIONS. DO NOT WATER-QUENCH OR CHROMATE-QUENCH GALVANIZED SURFACES TO BE POWDER COATED. AFTER PREPARING GALVANIZED SURFACES, POWDER COAT WITH A MINIMUM OF 2.0 MILS DRY FILM THICKNESS (DFT) OF URETHANE POWDER OR TRIGLYCIDYL ISOCYANURATE (TGIC) POLYESTER POWDER. PROVIDE POWDER COAT ADHESION MEETING THE 5A OR 5B CLASSIFICATIONS OF ASTM D3359.
ENSURE POWDER COATING IS UNIFORM IN APPEARANCE AND FREE OF SCRATCHES.
ITEM 687: PEDESTAL POLE ASSEMBLIES
GENERAL NOTES (4 OF 4)
7 of 60NTS
48" STM
15' UTILITY EASEMENT
25' BUILDING LINE
20' UTILITY EASEMENT
15' U
TILITY EASEM
EN
T/15' BU
ILD
IN
G
LIN
E
20' UTILITY EASEMENT
25' BUILDING LINE
15' BU
ILD
IN
G
LIN
E
25' BUILDING LINE
25' BUILDING LINE
25' BUILDING LINE
10'x20' STM. S.E.
W M
W
MCTC C
T
C
W
MW
M
V
P
48" STM
48" STM D
D
D
" S
TM
AT&T/SWBT BURIED CABLE
AT&T/SWBT BURIED CABLE
AT&T/SWBT BURIED CABLEU/G WATERLINE
U/G GAS LINE
U /G
G
AS LIN
E
U /G
W
ATER
LIN
E
K:
\1
EN
G
\C ity o f R os en be rg
_0
7\ 1-
-2
1_ Pl az a
D r @
C om m er ci al
D r S ig na l\
.0 0_
C A
D \0
7.
_D ra w in gs \8
E
XI
ST
IN
G C
O N
D
ITI
O N
S
LA
YO
UT
.d w g A pr
3, 4-
4:
EER
STATE OF TEXAS
BONNIE C. MOSS
Drawn:
Sheet:
NAMEDATEREVISIONSNO. TRAFFIC SIGNAL INSTALLATION TO SERVE
PLAZA DRIVE AT COMMERCIAL DRIVE
Date:
Checked: Scale:
Job No.:
GG
SJ 1-0127-2301
1505 Highway 6 South, Suite 180 Houston, Texas 77077 281.760.1656 MBCOEngineering.com
SBE/WBE/DBE/HUB
TBPELS Engineering Firm No. F-16850 Land Surveying Firm No. 10194810
April 2024
EXISTING CONDITIONS LAYOUT
8 of 601"=60'
SCALE IN FEET
4020 80
BB INLET
CABLE MARKER
CM
DA
DAS
FIRE HYDRANT
GUY ANCHOR
C HAND HOLE COMM
ICV
IRF
C JBT
ONLY
PMCA
PME
PMFO
PMG
PMTE
PMWW
POWER POLE
T POWER POLE TRANS
S SANITARY MANHOLE
SIGN
SMALL LIGHT POLE
D STORM MANHOLE
T TELE PED
TRANSFORMER
TRAVERSE
TREE
WM WATER METER
WATER VALVE
FLOODPLAIN NOTE:
THIS TRACT LIES IN ZONE "X" (UNSHADED), DESIGNATED AS “AREAS
DETERMINED TO BE OUTSIDE THE 0.2% ANNUAL CHANCE FLOODPLAIN",
AS PER THE NATIONAL FLOOD INSURANCE PROGRAM FIRM COMMUNITY
PANEL NUMBER 48157C0245L, LATEST AVAILABLE PUBLISHED REVISION
DATED APRIL 2, 2014.
BENCHMARK NOTE:
VERTICAL DATUM REFERENCED HEREON IS BASED ON NAVD 1988, GEOID
2018.
SITE BENCHMARK NOTE:
FORT BEND COUNTY MARKER 224 IS A BRONZE DISK IN CONCRETE,
LOCATED NORTHWEST CORNER OF LOT 1. BLOCK2, AT THE
INTERSECTION OF HONEYSUCKLE VINE DRIVE AND RIVER DELTA LANE.
4.4' FROM BACK OF CURB OF HONEYSCUKLE VINE DRIVE, RIVER'S MIST
SUBDIVSION, SECTION 1, RECORDED UNDER PLAT NUMBER 20060288
FORT BEND COUNTY PLAT RECORDS.
KEY MAP 605V.
ELEV. 86.496 FEET (NAVD88), 2001 ADJ.
LEGEND
SIGN LEGEND
STOP
R1-1
48" STM
EXP JT
PL
AZ
A D
R
COMMERCIAL DR
R.O.W.
R.O.W.
R.O.W.
R.O.W.
R .O
.W
R .O
.W
R .O
.W
. EXP JT
EXP JT
EXP JT
EXP JT
EXP JT EXP JT
EXP JT
EXP JT EXP JT
EX
P
JT
EX
P
JT
EX
P
JT
EX
P
JT
EX
P
JT
EX
P
JT
EX
P
JT
EX
P
JT
24" STOP BAR
24" STOP BAR
EX
P
JT
EX
P
JT
EX
P
JT
EX
P
JT
EX
P
JT
EX
P
JT
EX
P
JT
EX
P
JT
EX
P
JT
EX
P
JT
24" STOP BAR
UG WATERLINE U/G COM
(BY OTHERS)
U/G COM
(BY OTHERS)
U/G GAS LINE
U/G GAS LINE
30" STM 48" STM
24" STM
24" STM
UG WATERLINE
U/G GAS LINE
NO
TRUCKS
R5-2A
NO
PARKING
R8-3KT
TRUCK
SOUTH WEST FRWY FRONTAGE ROAD
AutoCAD SHX Text
STOP
AutoCAD SHX Text
STOP
AutoCAD SHX Text 4/3/24
ONLY
11+00 12+00 13+00 14+00 15+00 16+00 16+34
+0
+0
+0
+0
+2
W M
W
MCTC C
T
C
W
MW
M
V
P
D D
D
K:
\1
EN
G
\C ity o f R os en be rg
_0
7\ 1-
-2
1_ Pl az a
D r @
C om m er ci al
D r S ig na l\
.0 0_
C A
D \0
7.
_D ra w in gs \9
T
RA
FF
IC
S
IG
N A
L
LA
YO
UT
.d w g A pr
3, 4-
4:
EER
STATE OF TEXAS
BONNIE C. MOSS
Drawn:
Sheet:
NAMEDATEREVISIONSNO. TRAFFIC SIGNAL INSTALLATION TO SERVE
PLAZA DRIVE AT COMMERCIAL DRIVE
Date:
Checked: Scale:
Job No.:
GG
SJ 1-0127-2301
1505 Highway 6 South, Suite 180 Houston, Texas 77077 281.760.1656 MBCOEngineering.com
SBE/WBE/DBE/HUB
TBPELS Engineering Firm No. F-16850 Land Surveying Firm No. 10194810
April 2024
1"=40'
SCALE IN FEET
4020 80
LEGEND
PROP TRAFFIC SIGNAL POLE
PROP VEHICLE SIGNAL HEAD
PROP PEDESTRIAN SIGNAL HEAD
PROP PEDESTRIAN PUSH BUTTON
PROP PEDESTRIAN POLE
PROP PULL BOX
PROP GROUND BOX
PROP VIVDS
PROP CONDUIT
PROP BORE & JACK
POSTED SPEED LIMIT:
PLAZA DRIVE: 30 MPH
COMMERCIAL DRIVE: 30 MPH
POLE 5
POLE 1 POLE 2
PROP LUMINAIRE
PROP CONTROLLER CABINET
PROP SERVICE POLE W/ METER
PROP RUN NUMBER
SIGNAL DESIGNATION
OVERHEAD SIGN DESIGNATION
A
S3
PL
AZ
A D
R
COMMERCIAL DR
R.O.W.
R.O.W.
R.O.W.
R.O.W.
R .O
.W
R .O
.W
POLE 4
36 LF MAST ARM
POLE 1
32 LF MAST ARM
POLE 6
32 LF MAST ARM
POLE 7
55 LF MAST ARM
POLE 2
POLE 5
PROP 10'
ESMT.
PROP 10'
ESMT.
TRAFFIC SIGNAL LAYOUT
SOUTH WEST FRWY FRONTAGE ROAD
POLE 3
POLE 6
POLE 3
POLE 8
Pb4
W4
Pb3
W3
Pb6
Pb5
W6
W5
Pb1
W1 Pb2
W2
W7
Pb8
Pb7 W8
E F G
S1
S3
S3
S3
S1
H
J
AB
C
D
90'100'
90'100' 90'
90' 100'
100'
Ø8
Ø3
Ø
Ø
Ø
Ø4
Ø7
0'
0'
14 15
SERVICE POLE 8
S2
V2
V4
V1
V3
PROP 5'
ESMT
PROP 10'
ESMT
S2
NOTES:
1. THE CONTRACTOR SHALL LOCATE/EXPOSE ALL UTILITIES THAT MAY
BE IN CONFLICT WITH SIGNAL POLE LOCATIONS BY HAND
EXCAVATION PRIOR TO CONSTRUCTION. IF UTILITIES ARE IN
CONFLICT THE ENGINEER SHALL BE CONTACTED TO FIND AN
ALTERNATE LOCATION FOR THE SIGNAL POLES.
2. IT IS THE CONTRACTORS RESPONSIBILITIES TO LOCATE ALL
SPRINKLERS SYSTEMS, CONTROLS AND WIRES PRIOR TO
CONSTRUCTION. IF DAMAGED DURING CONSTRUCTION, ALL
EXPENSE FOR REPAIR OF ANY OF THESE SHALL BE BORNE BY THE
CONTRACTOR. THERE WILL BE NO ADDITIONAL COMPENSATION.
ANY REPAIRS SHALL BE APPROVED BY THE CITY OF ROSENBERG
OR THE DEVELOPER .
3. HOME DEPOT EXIT/ENTRANCE TO REMAIN OPEN AT ALL TIMES.
CONTRACTOR SHALL SUBMIT TEMPORARY TCP PLAN TO ENGINEER
FOR APPROVAL PRIOR TO BEGINNING CONSTRUCTION AT THIS
LOCATION.
4. NO WEEKEND LANE CLOSURES. ANY LANE CLOSURES TO BE DONE
AT NIGHT.
CAUTION: EXISTING UTILITIES IN
AREA. CONTRACTOR SHALL EXPOSE ALL
UTILITIES PRIOR TO DRILLING FOR SIGNAL
FOUNDATIONS. TYP ALL SIGNAL POLES.
EXIST POWER POLE TO BE
RELOCATED BY CENTERPOINT
ENERGY
AutoCAD SHX Text
STOP
AutoCAD SHX Text
STOP
EN
G
\C ity o f R os en be rg
_0
7\ 1-
-2
1_ Pl az a
D r @
C om m er ci al
D r S ig na l\
.0 0_
C A
D \0
7.
_D ra w in gs \1
TR
A
FF
IC
S
IG
N
A L
LA
YO
UT
D
ET
A
IL
S.
d w g A pr
3, 4-
4:
EER
STATE OF TEXAS
BONNIE C. MOSS
Drawn:
Sheet:
NAMEDATEREVISIONSNO. TRAFFIC SIGNAL INSTALLATION TO SERVE
PLAZA DRIVE AT COMMERCIAL DRIVE
Date:
Checked: Scale:
Job No.:
GG
SJ 1-0127-2301
1505 Highway 6 South, Suite 180 Houston, Texas 77077 281.760.1656 MBCOEngineering.com
SBE/WBE/DBE/HUB
TBPELS Engineering Firm No. F-16850 Land Surveying Firm No. 10194810
April 2024
TRAFFIC SIGNAL LAYOUT DETAILS
10 of 60NTS
Y GR
1 WAY, 3-SECTION
12" LENS HORIZONTAL
LED SIGNAL HEAD
PROPOSED SIGNALS HEAD SCHEDULE
SIGNAL FACE DESIGNATION
R10-3eR 9"X15"
(Pb2,Pb4,Pb6,Pb8)
W1, W2, W3, W4, W5, W6, W7, W8
R10-3eL 9"X15"
(Pb1,Pb3,Pb5,Pb7)
R Y GY
1 WAY, 4-SECTION
12" LENS HORIZONTAL
LED SIGNAL HEAD
DES.
PROPOSED SIGNS SCHEDULE
SIGN DESIGN
COMMERCIAL DRIVE
03 07
PLAZA DRIVE
PHASE IN
RING 1
PHASE IN
RING 2
PHASING DIAGRAM
COUNT DOWN
PEDESTRIAN
LAMP
16"x18"
L E FT T U R N
Y I E L D
O N F LAS H I N G
Y E L L OW
AR R OW
R10-17T 36"X42"
DES.
PROPOSED SIGNS SCHEDULE
SIGN DESIGN
S1
S2
S3
A B D
F G
4.5 67.5
6 5.5 4.5
5 7
1.5" Radius, 1.0" Border, White on Green;
[Commercial] ClearviewHwy-3-W; [Dr] ClearviewHwy-3-W;
Table of letter and object lefts.
C 4.5 o 11.6 m 19.3 m 29.9 e 40.2 r 47.5 c 52.3 i 58.8 a 62.3 l 69.7
D 78.0 r 81.9
4.7 29.1
6 5.5 4.7
5 7
1.5" Radius, 1.0" Border, White on Green;
[Plaza] ClearviewHwy-3-W; [Dr] ClearviewHwy-3-W;
Table of letter and object lefts.
P 4.7 l 11.9 a 15.6 z 22.6 a 28.4
D 39.8 r 43.7
C E H
J
N/A
+0
+0
+0
+0
+2
W M
W
MCTC C
T
C
W
MW
M
V
P
D D
D
D
C
W M
W M
K:
\1
EN
G
\C ity o f R os en be rg
_0
7\ 1-
-2
1_ Pl az a
D r @
C om m er ci al
D r S ig na l\
.0 0_
C A
D \0
7.
_D ra w in gs \1
PA
V
IN
G
IM
PR
O
V
EM
EN
TS
L A
YO
UT
.d w g A pr
3, 4-
5:
L IC E NS EDPROFES S IO NA L E NGIN
EER
STATE OF TEXAS
BONNIE C. MOSS
Drawn:
Sheet:
NAMEDATEREVISIONSNO. TRAFFIC SIGNAL INSTALLATION TO SERVE
PLAZA DRIVE AT COMMERCIAL DRIVE
Date:
Checked: Scale:
Job No.:
GG
SJ 1-0127-2301
1505 Highway 6 South, Suite 180 Houston, Texas 77077 281.760.1656 MBCOEngineering.com
SBE/WBE/DBE/HUB
TBPELS Engineering Firm No. F-16850 Land Surveying Firm No. 10194810
April 2024
PAVING IMPROVEMENTS LAYOUT
11 of 601"=40'
SCALE IN FEET
4020 80
DETAIL 3
1"=20'
DETAIL 4
1"=20'
PL
AZ
A D
R
COMMERCIAL DR
R.O.W.
R.O.W.
R.O.W.
R.O.W.
R .O
.W
R .O
.W
DETAIL 1
1"=20' DETAIL 2
1"=20'
PROP TY 7
CURB RAMP
SEE DETAIL 2
PROP TY 7
CURB RAMP
SEE DETAIL 1
PROP TY 5
CURB RAMP
SEE DETAIL 3
PROP TY 5
CURB RAMP
SEE DETAIL 4
1:12
MAX
1:12
MAX
LANDING
1:50 MAX
TRUNCATED
DOMES
TRUNCATED
DOMES
TRUNCATED
DOMES
TRUNCATED
DOMES1:12
MAX
1:12
MAX
LANDING
1:50 MAX
LANDING
1:50 MAX
LANDING
1:50 MAX
REMOVE 5 LF
CONC CURB (TY II)
REMOVE 5 LF
CONC CURB (TY II)
REMOVE 5 LF
CONC CURB (TY II)
REMOVE 5 LF
CONC CURB (TY II)
TRUNCATED
DOMES TRUNCATED
DOMES
REMOVE 20 LF
CONC CURB (TY II)
REMOVE 20 LF
CONC CURB (TY II)
1:50
MAX
1:50
MAX
SOUTH WEST FRWY FRONTAGE ROAD
PROP
SIDEWALK
PROP
SIDEWALKA
B C
D
E
F
G
H
NOTES:
1. CITY OF ROSENBERG TO REMOVE & RELOCATE EXISTING IRRIGATION
SYSTEM.
2. CITY OF ROSENBERG TO REMOVE THESE TWO TREES AND
RELOCATE AS REQUIRED.
3. CONTRACTOR TO RELOCATE EXISTING SIGNS AS NECESSARY.
42'
11'
EXIST SIGN TO
BE REMOVED
SEE NOTE 3.
EXIST SIGN TO
BE REMOVED
EXIST SIGN TO
BE REMOVED
EXIST SIGN
TO REMOVED
10'
12'
16'
42'
PROP SAWCUT
18'
R4'
R90'
R500'
R500'
EXIST IRON ROD
TO BE DESTROYED
SEE NOTE 3.
12'
CITY OF ROSENBERG TO CONSTRUCT LEFT
TURN LANE ALONG PLAZA DRIVE PRIOR TO
SIGNAL INSTALLATION. CITY TO RELOCATE
TREES AND IRRIGATION SYSTEM AS REQUIRED
(SEE NOTES 1 & 2 , THIS SHEET). CONTRACTOR
TO CONSTRUCT RAMPS AND SIDEWALK
RELATED TO THE PROP TRAFFIC SIGNAL.
AutoCAD SHX Text
STOP
AutoCAD SHX Text
STOP
+0
+0
+0
+0
+2
W M
W
MCTC C
T
C
W
MW
M
V
P
K:
\1
EN
G
\C ity o f R os en be rg
_0
7\ 1-
-2
1_ Pl az a
D r @
C om m er ci al
D r S ig na l\
.0 0_
C A
D \0
7.
_D ra w in gs \1
PA
V
EM
EN
T
M A
RK
IN
G L
A
YO
UT
.d w g
A pr
3, 4- 4:
EER
STATE OF TEXAS
BONNIE C. MOSS
Drawn:
Sheet:
NAMEDATEREVISIONSNO. TRAFFIC SIGNAL INSTALLATION TO SERVE
PLAZA DRIVE AT COMMERCIAL DRIVE
Date:
Checked: Scale:
Job No.:
GG
SJ 1-0127-2301
1505 Highway 6 South, Suite 180 Houston, Texas 77077 281.760.1656 MBCOEngineering.com
SBE/WBE/DBE/HUB
TBPELS Engineering Firm No. F-16850 Land Surveying Firm No. 10194810
April 2024
SCALE IN FEET
4020 80
PL
AZ
A D
R
COMMERCIAL DR
R.O.W.
R.O.W.
R.O.W.
R.O.W.
R .O
.W
LEGEND
REFL PAV MRK TY II-A-A
REFL PAV MRK TY I (W) (8") (SLD)(100MIL)
REFL PAV MRK TY I (W) (24") (SLD)(100MIL)
A
B
C
D
NOTES
1. ALL PAVEMENT MARKINGS SHALL BE INSTALLED IN ACCORDANCE WITH TxDOT STANDARD DETAILS
AND SPECIFICATIONS.
2. ALL STRIPING FOR STOP BARS, CROSSWALKS, AND LANE LINES SHALL BE TY I (THERMOPLASTIC).
3. EXISTING STRIPING IN CONFLICT WITH PROPOSED STRIPING SHALL BE REMOVED IN ACCORDANCE WITH TxDOT SPECIFICATIONS.
4. ALL CONSTRUCTION SIGNS AND BARRICADES SHALL CONFORM TO THE "TEXAS MANUAL ON
UNIFORM TRAFFIC CONTROL DEVICES", LATEST REVISION AND HCED STANDARD DETAILS.
5. PROPOSED SIGNS TO BE BAGGED UNTIL TRAFFIC SIGNAL IS OPERATIONAL.
6. NO WEEKEND LANE CLOSURES. ANY LANE CLOSURES TO BE DONE AT NIGHT.
REFL PAV MRK TY I (W) (ARROW)(100MIL)E
REFL PAV MRK TY I (W) (WORD)(100MIL)F
REFL PAV MRK TY II (Y) (MED-NOSE)G
REFL PAV MRK TY II-C-RH
REFL PAV MRK TY I-CI
REFL PAV MRK TY I (W) (6") (BRK)(100MIL)
PAVEMENT MARKING LAYOUT
12 of 601"=40'
R .O
.W
D
D
D
D
I
C
F
E
E
A
H
E
E
E
F
F
I
I C
C
REFL PAV MRK TY I (Y) (24") (SLD)(100MIL)J
D
D
D D
K
K
REFL PAV MRK TY I (Y) (6") (SLD)(100MIL)K
SOUTH WEST FRWY FRONTAGE ROAD
F
G
E
E
A
H
K
J
B
B
AutoCAD SHX Text
STOP
AutoCAD SHX Text
STOP
EN
G
\C ity o f R os en be rg
_0
7\ 1-
-2
1_ Pl az a
D r @
C om m er ci al
D r S ig na l\
.0 0_
C A
D \0
7.
_D ra w in gs \5
C
ITY
O
F
RO
SE
N
BE
RG
S
TA
N D
A
RD
D
ET
A
IL
S.
d w g
A pr
3, 4- 4:
EER
STATE OF TEXAS
BONNIE C. MOSS
Drawn:
Sheet:
NAMEDATEREVISIONSNO. TRAFFIC SIGNAL INSTALLATION TO SERVE
PLAZA DRIVE AT COMMERCIAL DRIVE
Date:
Checked: Scale:
Job No.:
GG
SJ 1-0127-2301
1505 Highway 6 South, Suite 180 Houston, Texas 77077 281.760.1656 MBCOEngineering.com
SBE/WBE/DBE/HUB
TBPELS Engineering Firm No. F-16850 Land Surveying Firm No. 10194810
April 2024
CITY OF ROSENBERG STANDARD
DETAIL
NTS 59 of 60
EN
G
\C ity o f R os en be rg
_0
7\ 1-
-2
1_ Pl az a
D r @
C om m er ci al
D r S ig na l\
.0 0_
C A
D \0
7.
_D ra w in gs \6
C
ITY
O
F
RO
SE
N
BE
RG
S
TA
N D
A
RD
D
ET
A
IL
S.
d w g
A pr
3, 4- 4:
EER
STATE OF TEXAS
BONNIE C. MOSS
Drawn:
Sheet:
NAMEDATEREVISIONSNO. TRAFFIC SIGNAL INSTALLATION TO SERVE
PLAZA DRIVE AT COMMERCIAL DRIVE
Date:
Checked: Scale:
Job No.:
GG
SJ 1-0127-2301
1505 Highway 6 South, Suite 180 Houston, Texas 77077 281.760.1656 MBCOEngineering.com
SBE/WBE/DBE/HUB
TBPELS Engineering Firm No. F-16850 Land Surveying Firm No. 10194810
April 2024
CITY OF ROSENBERG STANDARD
DETAILS
NTS 60 of 60
| Sheets and Views |
| 1 COVER SHEET |
| 2 INDEX SHEET |
| 3 SUMMARY OF QUANTITIES |
| 4 GENERAL NOTES (1 OF 4) |
| 5 GENERAL NOTES (2 OF 4) |
| 6 GENERAL NOTES (3 OF 4) |
| 7 GENERAL NOTES (4 OF 4) |
| 8 EXISTING CONDITIONS LAYOUT |
| 9 TRAFFIC SIGNAL LAYOUT |
| 10 TRAFFIC SIGNAL LAYOUT DETAILS |
| 11 PAVING IMPROVEMENTS LAYOUT |
| 12 PAVEMENT MARKING LAYOUT |
| 59 CITY OF ROSENBERG STANDARD DETAILS |
| 60 CITY OF ROSENBERG STANDARD DETAILS |