Perdido_Landfill_Maintenance_Facility_Retaining_Wall_Rehabilitation_Issued_for_Bid_20260723.pdf

PDF 19 MB Posted

Attached to
Perdido Landfill Retaining Wall Installation
Solicitation number
PD 25-26.109
Issued by
Escambia County, Canal Point CDP, Florida

About this file

This is a bid drawing package issued by Escambia County, Florida for the Perdido Landfill Maintenance Facility Retaining Wall Rehabilitation project (Project No. 10435192). The project, designed by HDR Engineering, Inc., involves the installation of a sheet pile retaining wall system at the Perdido Landfill located at 13009 Beulah Road, Cantonment, Florida. The scope of work includes furnishing all labor, materials, equipment, supervision, and incidentals necessary to construct a proposed steel sheet piling (SSP) wall with a concrete cap, install grouted soil anchors (22 pairs of AZ18-700 SSP anchors with 4.5 pairs of return wall anchors), and complete associated site work. The contractor must comply with all local, state, and federal safety codes and perform work during normal facility operating hours (Monday through Friday 7:00 a.m. to 5:00 p.m. and Saturday 7:00 a.m. to 3:30 p.m.). Work is permitted to commence on or after October 1, 2026, with equipment and supplies able to be staged onsite throughout the project duration. All questions regarding the project must be submitted through opengov.com, and any questions arising during onsite meetings must be documented and submitted through the same platform for engineer response.

The design specifications require materials including ASTM A572 Grade 60 steel sheet piling with corrosion-resistant coating, FDOT Class IV concrete with 5,500 PSI compressive strength for extremely aggressive environments, and grouted soil anchors designed by a Florida-licensed specialty engineer retained by the contractor. The contractor may select either tendon or bar anchorage systems for exclusive use throughout the project, with soil anchors requiring a lock-off load of 54 kips and a minimum estimated bond length of 30 feet for bidding purposes. Load testing must not commence until concrete and grout reach a minimum 70 percent of specified compressive strength. The project adheres to FDOT Structures Manual 2026, AASHTO LRFD Bridge Design Specifications (10th Edition 2026), and FDOT Standard Specifications for Road and Bridge Construction 2026. Required submittals include SSP installation and driving plans, concrete mix designs, reinforcing shop drawings, and grouted soil anchor installation plans with signed and sealed design calculations.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

VICINITY MAP

PROJECT

VICINITY

Perdido Landfill Maintenance Facility Retaining Wall Rehabilitation

Project No.

B i d D r a w i n g s F o r

10435192

July 2026

I N D E X O F D R A W I N G S

GENERAL

G-101 COVER SHEET

G-102 SITE PLAN

CIVIL

C101 PLAN VIEW

C102 SECTION A-A

C103 SOIL ANCHOR DETAILS

HDR ENGINEERING, INC.

76 SOUTH LAURA ST., SUITE 1600

JACKSONVILLE, FLORIDA 32202-4321

(904) 598-8900

Escambia County, FL

ISSUED FOR BID

NOT FOR CONSTRUCTION

CP 4

N 585868.89 E 1056060.35

EL. 123.32

CP 5

N 585877.32 E 1056325.10

EL. 126.88

CP 6

N 585508.63 E 1057471.58

EL. 132.58

80 80 80

909090

MAINTENANCE BUILDING

PROPERTY BOUNDARY

CONSTRUCTED WETLANDS

SOUTHWEST

STORMWATER BASIN

LANDFILL ENTRANCE

ADMINISTRATIVE BUILDING

HOUSEHOLD HAZARDOUS WASTE

SCALE HOUSE

MAINTENANCE FACILITY

CONSERVATION AREA

SE

CT

IO

N

3C

SE

CT

IO

N

3B

SE

CT

IO

N

3A

SE

CT

IO

N

2B

SE

CT

IO

N

2A

SE

CT

IO

N

SE

CT

IO

N

PROPERTY BOUNDARY

LEGEND

WETLAND LIMITS

NOTES:

1. AERIAL IMAGERY AND TOPOGRAPHY PROVIDED

BY INGENAE DATED APRIL 22, 2026.

2. EXISTING LINER LIMITS FOR SECTIONS 1 AND 2B

TAKEN FROM AS-BUILT DRAWINGS BY

DEPARTMENT OF PUBLIC WORKS, ESCAMBIA

COUNTY, FLORIDA, DATED 11-18-88 AND 4-24-97,

RESPECTIVELY. EXISTING LINER LIMITS OF

CELL 2A TAKEN FROM AS-BUILT DRAWING BY

ESCAMBIA COUNTY SOLID WASTE DEPARTMENT

DATED 11-92. EXISTING LINER LIMITS OF

SECTIONS 3A, 3B, AND 3C TAKEN FROM

PERDIDO CLASS I LANDFILL FDEP SUBMITTAL

SECTION 5 EXPANSION DRAWINGS BY HDR

DATED DECEMBER 2008. EXISTING LINER LIMITS

OF SECTION 4 TAKEN FROM TOPOGRAPHIC

SURVEY PERFORMED BY PICKETT &

ASSOCIATES, INC., DATED 4-29-08. EXISTING

LINER LIMITS OF CELL 1A TAKEN FROM

TOPOGRAPHIC SURVEY PERFORMED BY

PITTMAN, GLAZE AND ASSOCIATES, INC., DATED

3-7-19.

EXISTING MINOR CONTOUR

EXISTING MAJOR CONTOUR100

B

ISSUE DESCRIPTION

PROJECT MANAGER

PROJECT NUMBER

0 1" 2"

FILE NAME

SCALE

SHEET

DATE

C

A

1 3 4 5 6 7 8

C:

\P

W W

OR

KI

NG

\E

AS

T0

2\D

2\G

2.D W

G

/08 /20

:57 :56

A M

PERDIDO LANDFILL

MAINTENANCE FACILITY

RETAINING WALL REHABILITATION

ESCAMBIA COUNTY, FLORIDA

K. PERERA, P.E.

10435192

S. MERSDORF, P.E.

J. RAYMOND

T. RILEY, P.E.

HDR ENGINEERING, INC.

76 S. LAURA STREET, STE. 1600

JACKSONVILLE, FL 32202

(904) 598-8900

DESIGNED BY

DRAWN BY

A 07/23/2026 ISSUED FOR BID

ISSUED FOR BID

NOT FOR CONSTRUCTION

CHECKED BY

SITE PLAN

G102 G102.dwg 1" = 100'

EXISTING LINED CLASS I LANDFILL

EXISTING CELL LIMITS

SECTION 5 LIMITS

RETAINING WALL

PROJECT LOCATION

100100 0 200

SCALE IN FEET

CONTROL POINT

104'± PROPOSED BULKHEAD

22 PAIRS AZ18-700 SSP

24'± RETURN W

ALL

4 1/2 PAIRS AZ18-700 SSP

ANCHORS (TBD)

10 SPACES AT 9'-2" = 91'-8"

9'- 2"

A

NC

HO

RS

A- A

C

B

ISSUE DESCRIPTION

PROJECT MANAGER

PROJECT NUMBER

0 1" 2"

FILE NAME

SCALE

SHEET

DATE

C

A

1 3 4 5 6 7 8

C:

\P

W W

OR

KI

NG

\E

AS

T0

2\D

2\C

1.D W

G

/08 /20

:57 :56

A M

PERDIDO LANDFILL

MAINTENANCE FACILITY

RETAINING WALL REHABILITATION

ESCAMBIA COUNTY, FLORIDA

K. PERERA, P.E.

10435192

S. MERSDORF, P.E.

J. RAYMOND

T. RILEY, P.E.

HDR ENGINEERING, INC.

76 S. LAURA STREET, STE. 1600

JACKSONVILLE, FL 32202

(904) 598-8900

DESIGNED BY

DRAWN BY

A 07/23/2026 ISSUED FOR BID

ISSUED FOR BID

NOT FOR CONSTRUCTION

CHECKED BY

PLAN VIEW

C101

C101.DWG

1" = 5'

EXISTING SECONDARY RETAINING WALL

APPROXIMATE EXISTING PRIMARY RETAINING WALL

PROPOSED SSP WALL

PROPOSED 3'X3' CONCRETE CAP

PROPOSED ANCHOR

(TYP.)

PROPOSED ANCHOR

(TYP.)

EXISTING STAIRS

EXISTING TIPPING AND SORTING BUILDING

N 585344.66 E 1056146.21

W8X21 TRIM TO FIT

EL 98 TO TOP OF SSP

AIR LIFT TO EL 98

AND FILL GROUT SOCK

WITH CEMENTIOUS GROUT

TO CAP SOFFIT

1" FIBER BOARD AGAINST EXISTING CONC.,

FULL DEPTH OF CONC. CAP

PROJECT NOTES

DESIGN STANDARDS

1. FLORIDA DEPARTMENT OF TRANSPORTATION (FDOT) STRUCTURES MANUAL -2026.

2. AMERICAN ASSOCIATION OF STATE HIGHWAY AND TRANSPORTATION OFFICIALS (AASHTO) LOAD RESISTANCE AND FACTOR DESIGN (LRFD) BRIDGE DESIGN SPECIFICATIONS, 10TH EDITION (2026).

3. DIVISIONS II & III OF FDOT STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE

CONSTRUCTION, 2026

4. ALL CONSTRUCTION SURVEY AND LAYOUT IS THE RESPONSIBILITY OF THE CONTRACTOR.

MATERIALS

1. STEEL SHEET PILING (SSP) SHALL CONFORM TO ASTM A572 GR 60.

2. ALL SHEET PILING SHALL BE COATED IN ACCORDANCE WITH SECTION 560 OF THE SPECIFICATIONS.

3. ALL STRUCTURAL STEEL AND PLATE STEEL SHALL CONFORM TO ASTM A572,

GRADE 60.

4. FILL MATERIAL INSTALLED BETWEEN THE EXISTING WALL AND NEW SHEET PILING SHALL BE SIZE #57

"GRAVEL" AND CONFORM TO SECTION 901 OF THE SPECIFICATIONS.

5. GROUTED SOIL ANCHOR MATERIALS SHALL CONFORM TO SECTION 451 OF THE SPECIFICATIONS.

6. CONCRETE SHALL BE FDOT CLASS IV IN EXTREMELY AGGRESSIVE ENVIRONMENT WITH 28 DAY

COMPRESSIVE STRENGTH OF 5,500 PSI.

7. REINFORCING SHALL CONFORM TO ASTM A615 GR 60. REINFORCING CHAIRS TO BE NON-FERROUS.

8. LAP SPLICES TO BE CLASS B SPLICES. STAGGER LAP SPLICES A MINIMUM OF 1/3 TENSION

DEVELOPMENT LENGTH.

SUBMITTALS

-SSP INSTALLATION AND DRIVING PLAN

-CONCRETE MIX DESIGN

-REINFORCING SHOP DRAWINGS

-GROUTED SOIL ANCHOR INSTALLION PLAN AND SIGNED / SEALED DESIGN CALCULATIONS.

-GROUTED SOIL ANCHOR SHOP DRAWINGS INCLUDING BEARING ASSEMBLY AND TRUMPET.

FILL SSP POCKET W/ CONC

PRIOR TO TESTING ANCHOR, TYP

PROVIDE 4'-0" X 4'-0" CORNER BARS

FOR EVERY LONGITUDINAL BAR

W8X21 TRIM TO FIT

EL 98 TO TOP OF SSP

AIR LIFT TO EL 98

AND FILL GROUT SOCK

WITH CEMENTIOUS GROUT

TO CAP SOFFIT

FIELD VERIFY EXISTING WALL ALIGNMENT

AND ELEVATION. ONCE FIELD

INFORMATION IS OBTAINED, CONTACT

ENGINEER FOR POTENTIAL WALL

ALIGNMENT/ELEVATION REVISIONS TO

MATCH EXISTING CONDITIONS.

55 0 10

SCALE IN FEET

B

ISSUE DESCRIPTION

PROJECT MANAGER

PROJECT NUMBER

0 1" 2"

FILE NAME

SCALE

SHEET

DATE

C

A

1 3 4 5 6 7 8

C:

\P

W W

OR

KI

NG

\E

AS

T0

2\D

2\C

2.D W

G

/08 /20

:57 :56

A M

PERDIDO LANDFILL

MAINTENANCE FACILITY

RETAINING WALL REHABILITATION

ESCAMBIA COUNTY, FLORIDA

K. PERERA, P.E.

10435192

S. MERSDORF, P.E.

J. RAYMOND

T. RILEY, P.E.

HDR ENGINEERING, INC.

76 S. LAURA STREET, STE. 1600

JACKSONVILLE, FL 32202

(904) 598-8900

DESIGNED BY

DRAWN BY

A 07/23/2026 ISSUED FOR BID

ISSUED FOR BID

NOT FOR CONSTRUCTION

CHECKED BY

SECTION A-A

C102

C102.DWG

1" = 2'

EXISTING TIPPING AND SORTING BUILDING

12" VERTICAL PILES WITH

12" HORIZONTAL PILES BEHIND

EXISTING SECONDARY RETAINING WALL

TO BE ABANDONED IN PLACE

PROPOSED CONCRETE CAP

PROPOSED SSP WALL

EXISTING PRIMARY RETAINING WALL

12" VERTICAL PILES WITH

12" HORIZONTAL PILES BEHIND

APPROX. EXISTING EL. 118

EL. 112

TOP CONC

EL. 111

SSP CUTOFF

EL. 109.75

TIEBACK

APPROX. EXISTING GROUND LINE EL. 103

TIP EL. 70

#57 STONE GRAVEL FILL

BELOW CAP SOFFIT

BEFORE ANCHORS AND

BEFORE CAP IS PLACED

#57 STONE ABOVE CAP SOFFIT AFTER CAP IS PLACED

PROPOSED ANCHOR

MIN FREE STRESSING LENGTH = 15'-0"

4" GAP

3" CLR, TYP

#5 @ 9"

20 #5 CONT

3'-0"

3'- 6"

BEARING PLATE ASSEMBLY

AND TRUMPET

CAP DETAIL, SEE DETAIL 1

THIS SHEET

C102

CAP DETAIL

3/4" = 1'-0"

1' 0 1' 2' 3'

5/16 5/16

3" DIA. WEEP HOLE

WITH HDG WIRE MESH COVER

EVERY 4'-7"

1'- 0"

TENDON BOND LENGTH

BOND LENGTH

FREE STRESSING LENGTH

TRUMPET

ANCHOR COVER

(REQUIRED)

FILLED WITH CORROSION

INHIBITING COMPOUND

OR GROUT PRESTRESSING

STEEL BAR

CENTRALIZER

GROUT FILLED

ENCAPSULATION

GROUT

END CAP

GROUT

BOND BREAKER

OVER GROUT FILLED

ENCAPSULATION

SEAL

BEARING PLATE

ANCHOR NUT

AND WASHER

FILLED WITH CORROSION

INHIBITING COMPOUND

OR GROUT

PRESTRESSING

STEEL BAR

DRILL HOLE

GROUT CENTRALIZER

GROUT FILLED

ENCAPSULATION

PRESTRESSING

STEEL BAR

DRILL HOLE

GROUT

BOND

BREAKER

GROUT FILLED

ENCAPSULATIONGROUT CENTRALIZER

PRESTRESSING

STEEL STRAND

WITH SHEATH

DRILL HOLE

TENDON BOND LENGTH

BOND LENGTH

FREE STRESSING LENGTH

TRUMPET

ANCHOR COVER

(REQUIRED)

FILLED WITH CORROSION

INHIBITING COMPOUND

OR GROUT

PRESTRESSING STEEL

STRAND INDIVIDUALLY COVERED

WITH CORROSION INHIBITING

COMPOUND & SHEATH

CENTRALIZER

GROUT FILLED

ENCAPSULATION

GROUT

GROUT

GROUT FILLED

ENCAPSULATION

SEAL

BEARING PLATE

WEDGE PLATE

& WEDGES

FILLED WITH CORROSION

INHIBITING COMPOUND

OR GROUT

DRILL HOLE

GROUT FILLED

ENCAPSULATION

GROUT

GROUT FILLED

ENCAPSULATION

SPACER

END CAP D

R

IL

L

H O

LE

D R

IL

L

H O

LE

BARE PRESTRESSING

STEEL STRAND

SPACER

A

A

B

B

A

A

B

B

5 3/8" 6 1/4" 5 3/8"

1'-5"

1' -5

5"

5/16"TYP.

A

1'- 0"

D C

B

1"

HOLE

1 1/2" THK.

PLATE (TYP.)

2" THK. PLATE

4 1/2"

1" THK. PLATE TYP.

2" THK. PLATE

1" THK. PLATE

A B C D 30° 4" 5 1/8"

BEARING PLATE TABLE

OF DIMENSIONS

3/ 4"

7 7/8"

1'-0"

6"

1/

8"

3/ 4"

±4"Ø SCH. 40 STEEL

TRUMPET (BY SOIL

ANCHOR ENGINEER)

1' -0

3 1/2" THK. PLATE6"

3 3/4"Ø HOLE

1/

8"

3 1/2" THK. PLATE

C103

TYPICAL TENDON SOIL ANCHOR DETAIL

NTS

NOTES:

1. ESTIMATED BOND LENGTH IS 30.0' FOR BIDDING PURPOSES.

2. DETAILS 1 AND 2 ON THIS SHEET ARE GENERIC AND FOR ILLUSTRATION PURPOSES ONLY. CONTRACTOR SHALL DESIGN, CONSTRUCT AND TEST ALL SOIL ANCHORS IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS.

3. SOIL ANCHOR DESIGN SHALL BE PERFORMED AND SEALED BY A FLORIDA-LICENSED SPECIALTY ENGINEER

RETAINED BY THE CONTRACTOR.

4. CONTRACTOR MAY SELECT EITHER TENDON OR BAR ANCHORAGE SYSTEMS TO BE USED EXCLUSIVELY

THROUGHOUT THE PROJECT.

5. LOCK OFF LOAD SHALL BE EQUAL TO 54 KIPS.

6. HEAD COVERS ARE REQUIRED TO PROTECT ANCHOR HEADS AGAINST CHLORIDE INTRUSION DURING CONSTRUCTION AND SHALL BE INSTALLED AND FILLED WITHIN 24 HOURS FOLLOWING LOCK OFF.

7. BEARING PLATES AND STRUCTURAL ANCHORAGE COMPONENTS AS DETAILED ARE DESIGNED FOR ONE EQUALLY-SIZED ANCHORS AT THE SPACINGS INDICATED, WITH A MAXIMUM APPLIED LOAD EQUAL TO 162 KIPS.

8. LOAD TESTING SHALL NOT BE CONDUCTED UNTIL THE CONCRETE AND GROUT HAS REACHED A MINIMUM 70% OF

THE SPECIFIED COMPRESSIVE STRENGTH.

9. CASING GREATER THAN 8" OUTER DIAMETER REQUIRES ENGINEER APPROVAL.

SECTION A-A SECTION B-B

C103

TYPICAL BAR SOIL ANCHOR DETAIL

NTS

SECTION A-A SECTION B-B

C103

BEARING PLATE ASSEMBLY DETAIL

1 1/2" = 1'-0"

C103

SOIL ANCHOR BEARING PLATE DETAIL

1 1/2" = 1'-0"

6"1' 0 1'6" 3"9" 6"1' 0 1'6" 3"9"

B

ISSUE DESCRIPTION

PROJECT MANAGER

PROJECT NUMBER

0 1" 2"

FILE NAME

SCALE

SHEET

DATE

C

A

1 3 4 5 6 7 8

C:

\P

W W

OR

KI

NG

\E

AS

T0

2\D

2\C

3.D W

G

/08 /20

:57 :56

A M

PERDIDO LANDFILL

MAINTENANCE FACILITY

RETAINING WALL REHABILITATION

ESCAMBIA COUNTY, FLORIDA

K. PERERA, P.E.

10435192

S. MERSDORF, P.E.

J. RAYMOND

T. RILEY, P.E.

HDR ENGINEERING, INC.

76 S. LAURA STREET, STE. 1600

JACKSONVILLE, FL 32202

(904) 598-8900

DESIGNED BY

DRAWN BY

A 07/23/2026 ISSUED FOR BID

ISSUED FOR BID

NOT FOR CONSTRUCTION

CHECKED BY

SOIL ANCHOR DETAILS

C103

C103.DWG

AS NOTED

Sheets and Views
G101-Layout1
G102-Plot
C101-PLOT
C102-PLOT
C103-PLOT

File details come from the government source that posted it. Updated .