Perdido_Landfill_Maintenance_Facility_Retaining_Wall_Rehabilitation_Issued_for_Bid_20260723.pdf
PDF 19 MB Posted
- Attached to
- Perdido Landfill Retaining Wall Installation
- Solicitation number
- PD 25-26.109
- Issued by
- Escambia County, Canal Point CDP, Florida
About this file
This is a bid drawing package issued by Escambia County, Florida for the Perdido Landfill Maintenance Facility Retaining Wall Rehabilitation project (Project No. 10435192). The project, designed by HDR Engineering, Inc., involves the installation of a sheet pile retaining wall system at the Perdido Landfill located at 13009 Beulah Road, Cantonment, Florida. The scope of work includes furnishing all labor, materials, equipment, supervision, and incidentals necessary to construct a proposed steel sheet piling (SSP) wall with a concrete cap, install grouted soil anchors (22 pairs of AZ18-700 SSP anchors with 4.5 pairs of return wall anchors), and complete associated site work. The contractor must comply with all local, state, and federal safety codes and perform work during normal facility operating hours (Monday through Friday 7:00 a.m. to 5:00 p.m. and Saturday 7:00 a.m. to 3:30 p.m.). Work is permitted to commence on or after October 1, 2026, with equipment and supplies able to be staged onsite throughout the project duration. All questions regarding the project must be submitted through opengov.com, and any questions arising during onsite meetings must be documented and submitted through the same platform for engineer response.
The design specifications require materials including ASTM A572 Grade 60 steel sheet piling with corrosion-resistant coating, FDOT Class IV concrete with 5,500 PSI compressive strength for extremely aggressive environments, and grouted soil anchors designed by a Florida-licensed specialty engineer retained by the contractor. The contractor may select either tendon or bar anchorage systems for exclusive use throughout the project, with soil anchors requiring a lock-off load of 54 kips and a minimum estimated bond length of 30 feet for bidding purposes. Load testing must not commence until concrete and grout reach a minimum 70 percent of specified compressive strength. The project adheres to FDOT Structures Manual 2026, AASHTO LRFD Bridge Design Specifications (10th Edition 2026), and FDOT Standard Specifications for Road and Bridge Construction 2026. Required submittals include SSP installation and driving plans, concrete mix designs, reinforcing shop drawings, and grouted soil anchor installation plans with signed and sealed design calculations.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
VICINITY MAP
PROJECT
VICINITY
Perdido Landfill Maintenance Facility Retaining Wall Rehabilitation
Project No.
B i d D r a w i n g s F o r
10435192
July 2026
I N D E X O F D R A W I N G S
GENERAL
G-101 COVER SHEET
G-102 SITE PLAN
CIVIL
C101 PLAN VIEW
C102 SECTION A-A
C103 SOIL ANCHOR DETAILS
HDR ENGINEERING, INC.
76 SOUTH LAURA ST., SUITE 1600
JACKSONVILLE, FLORIDA 32202-4321
(904) 598-8900
Escambia County, FL
ISSUED FOR BID
NOT FOR CONSTRUCTION
CP 4
N 585868.89 E 1056060.35
EL. 123.32
CP 5
N 585877.32 E 1056325.10
EL. 126.88
CP 6
N 585508.63 E 1057471.58
EL. 132.58
80 80 80
909090
MAINTENANCE BUILDING
PROPERTY BOUNDARY
CONSTRUCTED WETLANDS
SOUTHWEST
STORMWATER BASIN
LANDFILL ENTRANCE
ADMINISTRATIVE BUILDING
HOUSEHOLD HAZARDOUS WASTE
SCALE HOUSE
MAINTENANCE FACILITY
CONSERVATION AREA
SE
CT
IO
N
3C
SE
CT
IO
N
3B
SE
CT
IO
N
3A
SE
CT
IO
N
2B
SE
CT
IO
N
2A
SE
CT
IO
N
SE
CT
IO
N
PROPERTY BOUNDARY
LEGEND
WETLAND LIMITS
NOTES:
1. AERIAL IMAGERY AND TOPOGRAPHY PROVIDED
BY INGENAE DATED APRIL 22, 2026.
2. EXISTING LINER LIMITS FOR SECTIONS 1 AND 2B
TAKEN FROM AS-BUILT DRAWINGS BY
DEPARTMENT OF PUBLIC WORKS, ESCAMBIA
COUNTY, FLORIDA, DATED 11-18-88 AND 4-24-97,
RESPECTIVELY. EXISTING LINER LIMITS OF
CELL 2A TAKEN FROM AS-BUILT DRAWING BY
ESCAMBIA COUNTY SOLID WASTE DEPARTMENT
DATED 11-92. EXISTING LINER LIMITS OF
SECTIONS 3A, 3B, AND 3C TAKEN FROM
PERDIDO CLASS I LANDFILL FDEP SUBMITTAL
SECTION 5 EXPANSION DRAWINGS BY HDR
DATED DECEMBER 2008. EXISTING LINER LIMITS
OF SECTION 4 TAKEN FROM TOPOGRAPHIC
SURVEY PERFORMED BY PICKETT &
ASSOCIATES, INC., DATED 4-29-08. EXISTING
LINER LIMITS OF CELL 1A TAKEN FROM
TOPOGRAPHIC SURVEY PERFORMED BY
PITTMAN, GLAZE AND ASSOCIATES, INC., DATED
3-7-19.
EXISTING MINOR CONTOUR
EXISTING MAJOR CONTOUR100
B
ISSUE DESCRIPTION
PROJECT MANAGER
PROJECT NUMBER
0 1" 2"
FILE NAME
SCALE
SHEET
DATE
C
A
1 3 4 5 6 7 8
C:
\P
W W
OR
KI
NG
\E
AS
T0
2\D
2\G
2.D W
G
/08 /20
:57 :56
A M
PERDIDO LANDFILL
MAINTENANCE FACILITY
RETAINING WALL REHABILITATION
ESCAMBIA COUNTY, FLORIDA
K. PERERA, P.E.
10435192
S. MERSDORF, P.E.
J. RAYMOND
T. RILEY, P.E.
HDR ENGINEERING, INC.
76 S. LAURA STREET, STE. 1600
JACKSONVILLE, FL 32202
(904) 598-8900
DESIGNED BY
DRAWN BY
A 07/23/2026 ISSUED FOR BID
ISSUED FOR BID
NOT FOR CONSTRUCTION
CHECKED BY
SITE PLAN
G102 G102.dwg 1" = 100'
EXISTING LINED CLASS I LANDFILL
EXISTING CELL LIMITS
SECTION 5 LIMITS
RETAINING WALL
PROJECT LOCATION
100100 0 200
SCALE IN FEET
CONTROL POINT
104'± PROPOSED BULKHEAD
22 PAIRS AZ18-700 SSP
24'± RETURN W
ALL
4 1/2 PAIRS AZ18-700 SSP
ANCHORS (TBD)
10 SPACES AT 9'-2" = 91'-8"
9'- 2"
A
NC
HO
RS
A- A
C
B
ISSUE DESCRIPTION
PROJECT MANAGER
PROJECT NUMBER
0 1" 2"
FILE NAME
SCALE
SHEET
DATE
C
A
1 3 4 5 6 7 8
C:
\P
W W
OR
KI
NG
\E
AS
T0
2\D
2\C
1.D W
G
/08 /20
:57 :56
A M
PERDIDO LANDFILL
MAINTENANCE FACILITY
RETAINING WALL REHABILITATION
ESCAMBIA COUNTY, FLORIDA
K. PERERA, P.E.
10435192
S. MERSDORF, P.E.
J. RAYMOND
T. RILEY, P.E.
HDR ENGINEERING, INC.
76 S. LAURA STREET, STE. 1600
JACKSONVILLE, FL 32202
(904) 598-8900
DESIGNED BY
DRAWN BY
A 07/23/2026 ISSUED FOR BID
ISSUED FOR BID
NOT FOR CONSTRUCTION
CHECKED BY
PLAN VIEW
C101
C101.DWG
1" = 5'
EXISTING SECONDARY RETAINING WALL
APPROXIMATE EXISTING PRIMARY RETAINING WALL
PROPOSED SSP WALL
PROPOSED 3'X3' CONCRETE CAP
PROPOSED ANCHOR
(TYP.)
PROPOSED ANCHOR
(TYP.)
EXISTING STAIRS
EXISTING TIPPING AND SORTING BUILDING
N 585344.66 E 1056146.21
W8X21 TRIM TO FIT
EL 98 TO TOP OF SSP
AIR LIFT TO EL 98
AND FILL GROUT SOCK
WITH CEMENTIOUS GROUT
TO CAP SOFFIT
1" FIBER BOARD AGAINST EXISTING CONC.,
FULL DEPTH OF CONC. CAP
PROJECT NOTES
DESIGN STANDARDS
1. FLORIDA DEPARTMENT OF TRANSPORTATION (FDOT) STRUCTURES MANUAL -2026.
2. AMERICAN ASSOCIATION OF STATE HIGHWAY AND TRANSPORTATION OFFICIALS (AASHTO) LOAD RESISTANCE AND FACTOR DESIGN (LRFD) BRIDGE DESIGN SPECIFICATIONS, 10TH EDITION (2026).
3. DIVISIONS II & III OF FDOT STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE
CONSTRUCTION, 2026
4. ALL CONSTRUCTION SURVEY AND LAYOUT IS THE RESPONSIBILITY OF THE CONTRACTOR.
MATERIALS
1. STEEL SHEET PILING (SSP) SHALL CONFORM TO ASTM A572 GR 60.
2. ALL SHEET PILING SHALL BE COATED IN ACCORDANCE WITH SECTION 560 OF THE SPECIFICATIONS.
3. ALL STRUCTURAL STEEL AND PLATE STEEL SHALL CONFORM TO ASTM A572,
GRADE 60.
4. FILL MATERIAL INSTALLED BETWEEN THE EXISTING WALL AND NEW SHEET PILING SHALL BE SIZE #57
"GRAVEL" AND CONFORM TO SECTION 901 OF THE SPECIFICATIONS.
5. GROUTED SOIL ANCHOR MATERIALS SHALL CONFORM TO SECTION 451 OF THE SPECIFICATIONS.
6. CONCRETE SHALL BE FDOT CLASS IV IN EXTREMELY AGGRESSIVE ENVIRONMENT WITH 28 DAY
COMPRESSIVE STRENGTH OF 5,500 PSI.
7. REINFORCING SHALL CONFORM TO ASTM A615 GR 60. REINFORCING CHAIRS TO BE NON-FERROUS.
8. LAP SPLICES TO BE CLASS B SPLICES. STAGGER LAP SPLICES A MINIMUM OF 1/3 TENSION
DEVELOPMENT LENGTH.
SUBMITTALS
-SSP INSTALLATION AND DRIVING PLAN
-CONCRETE MIX DESIGN
-REINFORCING SHOP DRAWINGS
-GROUTED SOIL ANCHOR INSTALLION PLAN AND SIGNED / SEALED DESIGN CALCULATIONS.
-GROUTED SOIL ANCHOR SHOP DRAWINGS INCLUDING BEARING ASSEMBLY AND TRUMPET.
FILL SSP POCKET W/ CONC
PRIOR TO TESTING ANCHOR, TYP
PROVIDE 4'-0" X 4'-0" CORNER BARS
FOR EVERY LONGITUDINAL BAR
W8X21 TRIM TO FIT
EL 98 TO TOP OF SSP
AIR LIFT TO EL 98
AND FILL GROUT SOCK
WITH CEMENTIOUS GROUT
TO CAP SOFFIT
FIELD VERIFY EXISTING WALL ALIGNMENT
AND ELEVATION. ONCE FIELD
INFORMATION IS OBTAINED, CONTACT
ENGINEER FOR POTENTIAL WALL
ALIGNMENT/ELEVATION REVISIONS TO
MATCH EXISTING CONDITIONS.
55 0 10
SCALE IN FEET
B
ISSUE DESCRIPTION
PROJECT MANAGER
PROJECT NUMBER
0 1" 2"
FILE NAME
SCALE
SHEET
DATE
C
A
1 3 4 5 6 7 8
C:
\P
W W
OR
KI
NG
\E
AS
T0
2\D
2\C
2.D W
G
/08 /20
:57 :56
A M
PERDIDO LANDFILL
MAINTENANCE FACILITY
RETAINING WALL REHABILITATION
ESCAMBIA COUNTY, FLORIDA
K. PERERA, P.E.
10435192
S. MERSDORF, P.E.
J. RAYMOND
T. RILEY, P.E.
HDR ENGINEERING, INC.
76 S. LAURA STREET, STE. 1600
JACKSONVILLE, FL 32202
(904) 598-8900
DESIGNED BY
DRAWN BY
A 07/23/2026 ISSUED FOR BID
ISSUED FOR BID
NOT FOR CONSTRUCTION
CHECKED BY
SECTION A-A
C102
C102.DWG
1" = 2'
EXISTING TIPPING AND SORTING BUILDING
12" VERTICAL PILES WITH
12" HORIZONTAL PILES BEHIND
EXISTING SECONDARY RETAINING WALL
TO BE ABANDONED IN PLACE
PROPOSED CONCRETE CAP
PROPOSED SSP WALL
EXISTING PRIMARY RETAINING WALL
12" VERTICAL PILES WITH
12" HORIZONTAL PILES BEHIND
APPROX. EXISTING EL. 118
EL. 112
TOP CONC
EL. 111
SSP CUTOFF
EL. 109.75
TIEBACK
APPROX. EXISTING GROUND LINE EL. 103
TIP EL. 70
#57 STONE GRAVEL FILL
BELOW CAP SOFFIT
BEFORE ANCHORS AND
BEFORE CAP IS PLACED
#57 STONE ABOVE CAP SOFFIT AFTER CAP IS PLACED
PROPOSED ANCHOR
MIN FREE STRESSING LENGTH = 15'-0"
4" GAP
3" CLR, TYP
#5 @ 9"
20 #5 CONT
3'-0"
3'- 6"
BEARING PLATE ASSEMBLY
AND TRUMPET
CAP DETAIL, SEE DETAIL 1
THIS SHEET
C102
CAP DETAIL
3/4" = 1'-0"
1' 0 1' 2' 3'
5/16 5/16
3" DIA. WEEP HOLE
WITH HDG WIRE MESH COVER
EVERY 4'-7"
1'- 0"
TENDON BOND LENGTH
BOND LENGTH
FREE STRESSING LENGTH
TRUMPET
ANCHOR COVER
(REQUIRED)
FILLED WITH CORROSION
INHIBITING COMPOUND
OR GROUT PRESTRESSING
STEEL BAR
CENTRALIZER
GROUT FILLED
ENCAPSULATION
GROUT
END CAP
GROUT
BOND BREAKER
OVER GROUT FILLED
ENCAPSULATION
SEAL
BEARING PLATE
ANCHOR NUT
AND WASHER
FILLED WITH CORROSION
INHIBITING COMPOUND
OR GROUT
PRESTRESSING
STEEL BAR
DRILL HOLE
GROUT CENTRALIZER
GROUT FILLED
ENCAPSULATION
PRESTRESSING
STEEL BAR
DRILL HOLE
GROUT
BOND
BREAKER
GROUT FILLED
ENCAPSULATIONGROUT CENTRALIZER
PRESTRESSING
STEEL STRAND
WITH SHEATH
DRILL HOLE
TENDON BOND LENGTH
BOND LENGTH
FREE STRESSING LENGTH
TRUMPET
ANCHOR COVER
(REQUIRED)
FILLED WITH CORROSION
INHIBITING COMPOUND
OR GROUT
PRESTRESSING STEEL
STRAND INDIVIDUALLY COVERED
WITH CORROSION INHIBITING
COMPOUND & SHEATH
CENTRALIZER
GROUT FILLED
ENCAPSULATION
GROUT
GROUT
GROUT FILLED
ENCAPSULATION
SEAL
BEARING PLATE
WEDGE PLATE
& WEDGES
FILLED WITH CORROSION
INHIBITING COMPOUND
OR GROUT
DRILL HOLE
GROUT FILLED
ENCAPSULATION
GROUT
GROUT FILLED
ENCAPSULATION
SPACER
END CAP D
R
IL
L
H O
LE
D R
IL
L
H O
LE
BARE PRESTRESSING
STEEL STRAND
SPACER
A
A
B
B
A
A
B
B
5 3/8" 6 1/4" 5 3/8"
1'-5"
1' -5
5"
5/16"TYP.
A
1'- 0"
D C
B
1"
HOLE
1 1/2" THK.
PLATE (TYP.)
2" THK. PLATE
4 1/2"
1" THK. PLATE TYP.
2" THK. PLATE
1" THK. PLATE
A B C D 30° 4" 5 1/8"
BEARING PLATE TABLE
OF DIMENSIONS
3/ 4"
7 7/8"
1'-0"
6"
1/
8"
3/ 4"
±4"Ø SCH. 40 STEEL
TRUMPET (BY SOIL
ANCHOR ENGINEER)
1' -0
3 1/2" THK. PLATE6"
3 3/4"Ø HOLE
1/
8"
3 1/2" THK. PLATE
C103
TYPICAL TENDON SOIL ANCHOR DETAIL
NTS
NOTES:
1. ESTIMATED BOND LENGTH IS 30.0' FOR BIDDING PURPOSES.
2. DETAILS 1 AND 2 ON THIS SHEET ARE GENERIC AND FOR ILLUSTRATION PURPOSES ONLY. CONTRACTOR SHALL DESIGN, CONSTRUCT AND TEST ALL SOIL ANCHORS IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS.
3. SOIL ANCHOR DESIGN SHALL BE PERFORMED AND SEALED BY A FLORIDA-LICENSED SPECIALTY ENGINEER
RETAINED BY THE CONTRACTOR.
4. CONTRACTOR MAY SELECT EITHER TENDON OR BAR ANCHORAGE SYSTEMS TO BE USED EXCLUSIVELY
THROUGHOUT THE PROJECT.
5. LOCK OFF LOAD SHALL BE EQUAL TO 54 KIPS.
6. HEAD COVERS ARE REQUIRED TO PROTECT ANCHOR HEADS AGAINST CHLORIDE INTRUSION DURING CONSTRUCTION AND SHALL BE INSTALLED AND FILLED WITHIN 24 HOURS FOLLOWING LOCK OFF.
7. BEARING PLATES AND STRUCTURAL ANCHORAGE COMPONENTS AS DETAILED ARE DESIGNED FOR ONE EQUALLY-SIZED ANCHORS AT THE SPACINGS INDICATED, WITH A MAXIMUM APPLIED LOAD EQUAL TO 162 KIPS.
8. LOAD TESTING SHALL NOT BE CONDUCTED UNTIL THE CONCRETE AND GROUT HAS REACHED A MINIMUM 70% OF
THE SPECIFIED COMPRESSIVE STRENGTH.
9. CASING GREATER THAN 8" OUTER DIAMETER REQUIRES ENGINEER APPROVAL.
SECTION A-A SECTION B-B
C103
TYPICAL BAR SOIL ANCHOR DETAIL
NTS
SECTION A-A SECTION B-B
C103
BEARING PLATE ASSEMBLY DETAIL
1 1/2" = 1'-0"
C103
SOIL ANCHOR BEARING PLATE DETAIL
1 1/2" = 1'-0"
6"1' 0 1'6" 3"9" 6"1' 0 1'6" 3"9"
B
ISSUE DESCRIPTION
PROJECT MANAGER
PROJECT NUMBER
0 1" 2"
FILE NAME
SCALE
SHEET
DATE
C
A
1 3 4 5 6 7 8
C:
\P
W W
OR
KI
NG
\E
AS
T0
2\D
2\C
3.D W
G
/08 /20
:57 :56
A M
PERDIDO LANDFILL
MAINTENANCE FACILITY
RETAINING WALL REHABILITATION
ESCAMBIA COUNTY, FLORIDA
K. PERERA, P.E.
10435192
S. MERSDORF, P.E.
J. RAYMOND
T. RILEY, P.E.
HDR ENGINEERING, INC.
76 S. LAURA STREET, STE. 1600
JACKSONVILLE, FL 32202
(904) 598-8900
DESIGNED BY
DRAWN BY
A 07/23/2026 ISSUED FOR BID
ISSUED FOR BID
NOT FOR CONSTRUCTION
CHECKED BY
SOIL ANCHOR DETAILS
C103
C103.DWG
AS NOTED
| Sheets and Views |
| G101-Layout1 |
| G102-Plot |
| C101-PLOT |
| C102-PLOT |
| C103-PLOT |
File details come from the government source that posted it. Updated .