This is a design services solicitation advertisement issued by Stanly Community College for architectural and engineering services related to the Patterson Building Roof Replacement project. The project involves the complete removal and replacement of the roof system on the Patterson Building located at 141 College Drive, Albemarle, North Carolina. The two-story building, constructed in 1975, has approximately 22,940 square feet of roof area that was last replaced in 2003 with a gravel system. The new roof will be replaced with either a Thermoplastic Polyolefin (TPO) roof system or a FiberTite roof system. Proposing firms must submit a Letter of Interest not exceeding ten single-sided pages or five double-sided pages, along with a current Standard Form 254 (SF-254) and licensing information via e-submission only. The submission format must be 8.5" x 11" pages stapled in the upper left-hand corner without binders, tabs, or clips.
The selection committee will evaluate proposals based on ten criteria including specialized expertise in roofing projects, past performance on similar projects, adequate staffing and consultant team composition, current workload, proposed design approach, recent experience with project costs and schedules, construction administration capabilities, proximity to and familiarity with the project location, record of successfully completed projects, and other appropriate factors. Proposing firms must be properly licensed to practice architecture or engineering in North Carolina according to the NC Board of Architecture, NC Board of Examiners for Engineers and Surveyors, or NC Board of Landscape Architects. Contact Shannon Shepherd, Director of Administrative and Facility Services, at sshepherd2420@stanly.edu for additional information. The project is identified as NCCS #3015 and SCO #31141.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Department/Agency Stanly Community College
| Project Title |
| Patterson Building Roof Replacement |
| Design Services |
| Complete roof removal and replacement |
| Scope of Work |
| SCC is in search of a designer for the Patterson Building Roof Replacement project. Patterson was constructed in 1975. The building has a gravel roof, most recently replaced in 2003. The roof of this two-story building is roughly 22,940 sq. ft. Patterson is located at 141 College Drive, Albemarle, NC. The project will include the full removal of the current roofing system. Roof to be replaced with either a Thermoplastic Polyolefin roof system (TPO) or FiberTite roof system. |
| Contact |
| Shannon Shepherd, Director Administrative and Facility Services |
| sshepherd2420@stanly.edu |
NCCS #3015; SCO #31141
| Submit Letter of Interest. SF-254, and Licensing Information: |
| e-submissions only |
| NC Licensing Statement |
| In order to offer architectural, engineering, or landscape architectural services in response to this solicitation, the proposing firm must be properly licensed to practice Architecture, Engineering, or Landscape Architecture in the State of North Carolina. More information on the North Carolina state boards may be found at the following websites: |
NC Board of Architecture: (http://www.ncbarch.org) NC Board of Examiners for Engineers & Surveyors: (http://www.ncbels.org) NC Board of Landscape Architects: (http://www.ncbola.org)
STATE BUILDING COMMISSION - SELECTING CRITERIA
In selecting designers, the selection committee should take into consideration qualification information including such factors as:
1. Specialized or appropriate expertise in the type of project.
2. Past performance on similar projects.
3. Adequate staff and proposed design or consultant team for the project.
4. Current workload and State projects awarded.
5. Proposed design approach for the project including design team and consultants.
6. Recent experience with project costs and schedules.
7. Construction administration capabilities.
8. Proximity to and familiarity with the area where the project is located.
9. Record of successfully completed projects without major legal or technical problems.
10. Other factors which may be appropriate for the project.
STATE BUILDING COMMISSION - SUBMITTAL CRITERIA
Proposing firms must submit a Letter of Interest and a copy of your current Standard Form 254 (SF 254) with the information package. The current SF 254 template is located at http://ncadmin.nc.gov/businesses/construction/forms-documents which is the State Building Commission approved form.
In the interest of cost-savings to the designers, consistency of the submittals and more efficient use of time by the pre-selection committee, the submitted information package should not include any notebooks, binders, tab, clips, etc. The format should be 8-1/2" x 11" pages stapled in the upper left-hand corner. The Letter of Interest should not exceed ten (10) single-sided pages or five (5) double-sided pages plus the SF 254.
E-mail and Fax submittals will not be accepted.