Part 3 Addendum No_ 3_Tift Co_ EB P1B.pdf
PDF 19 MB Posted
- Attached to
- EB Hamilton Sports Complex Improvements Phase 1B
- Solicitation number
- PE-77648-NONST-2024-000000007
- Issued by
- Terrell County, Georgia
About this file
This document is an Addendum No. 3 for the EB Hamilton Sports Complex Improvements Phase 1B project in Tift County, Georgia. The work consists of constructing baseball/softball/tee ball fields, with associated fencing, ballfield lighting, irrigation, grading, erosion and sediment control, utilities, storm drainage, and concrete sidewalks. The addendum provides clarification and changes to the original solicitation, including revised bid item quantities and installation requirements. The bid due date is November 16, 2022.
The document outlines pricing terms, including unit prices for the various bid items. No set-asides or incumbents are mentioned. Funding for the project is provided by state and local sources, though specific amounts are not disclosed. The contract term and any renewal options are not specified in this addendum.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
C o n s u l t i n g
E n g i n e e r s
Date:
Sheet #:
CAD By:
Proj. #:
R E
V
D E
S C
R I P
T I O
N D
A T
E
T if t o n
G e o r g ia
W h id d
M il l
R d
P h o n e
W
W A
T K I N
S E
N G C
O M
W a t k i s
A s o c i a t e s
L L C
C O
A
P
E F x p ir a t io n
O F
C
O M
M I S
S I
O N
E R
S
T I F
T
C
O U
N T
Y
B
O A
R D
F O
R
T
H E
I M
P R
O V
E M
E N
T S
P
H A
S E
B
E B
H
M I L
T O
N
S
P O
R T
S
C
O M
P L
E X
W2036-124-01
CADD PLOT
ccobb
09:54
05-JUN-2024
E:\Tifton EB Hamilton Rec Fields - 24014.01\CADD\E1 W2036-124-01.dgn
6/5/24
ELECTRIC BOXES
TRANSFORMER
WV
WV
WVWVWVWV
TRANSFORMER
E
LE
C T R
IC
B
O X E S
WV
225'
FIELD 1 225'
FIELD 2
225'
FIELD 3
225'
FIELD 4
200'
FIELD 5
300'
FIELD 7
225'
FIELD 6
300'
FIELD 8
EQUIPMENT
IRRIGATION
PAVILION
EXISTING
TRANSFORMER
CLEARING LIMIT
C L E
A R
IN
G L
IM
IT
C L
E A
R
IN
G L
IM
IT
C
LEA
R
IN
G
LIM
IT
SCOREBOARD
SCOREBOARD
SCOREBOARD
SCOREBOARD
SCOREBOARD
SCOREBOARD
SCOREBOARD
SCOREBOARD
W/ 1NO.6(G)
ƒ"C SCH. 80 PVC
W/ 1NO.6(G)
ƒ"C SCH. 80 PVC
W/ 1NO.6(G)
ƒ"C SCH. 80 PVC
W/ 1NO.6(G)
ƒ"C SCH. 80 PVC
W/ 1NO.6(G)
ƒ"C SCH. 80 PVC
W/ 1NO.6(G)
ƒ"C SCH. 80 PVC
W/ 1NO.6(G)
ƒ"C SCH. 80 PVC
W/ 1NO.6(G)
ƒ"C SCH. 80 PVC
EXISTING TRANSFORMER
EXISTING TRANSFORMER
NOTE G1,G2,G3
NOTE G1,G2,G3
NOTE G1,G2,G3
NOTE G1,G2,G3
NOTE G1,G2,G3
NOTE G1,G2,G3
NOTE G1,G2,G3
NOTE G1,G2,G3
TYPICAL , NOTE G7
SCORE BOOTH,
TYPICAL , NOTE G7
SCORE BOOTH,
TYPICAL , NOTE G7
SCORE BOOTH,
TYPICAL , NOTE G7
SCORE BOOTH,
TYPICAL , NOTE G7
SCORE BOOTH,
TYPICAL , NOTE G7
SCORE BOOTH,
NOTE G8
EXISTING EQUIPMENT RACK
NOTE G9
EXISTING EQUIPMENT RACK
NOTE G5
NOTE G5
NOTE G5
NOTE G5
NOTE G5
NOTE G5
NOTE G5
NOTE G5
E1
WP
LEGEND
GF
WP
PROPOSED SITE IMPROVEMENTS & LEGEND
JV
J
NOTE G6
IN GRADE
WP 20A
PITCHING MACHINE OUTLET
NOTE G6
IN GRADE
WP 20A
PITCHING MACHINE OUTLET
NOTE G6
IN GRADE
WP 20A
PITCHING MACHINE OUTLET
NOTE G6
IN GRADE
WP 20A
PITCHING MACHINE OUTLET
NOTE G6
IN GRADE
WP 20A
PITCHING MACHINE OUTLET
NOTE G6
IN GRADE
WP 20A
PITCHING MACHINE OUTLET
NOTE G6
IN GRADE
WP 20A
PITCHING MACHINE OUTLET
NOTE G6
IN GRADE
WP 20A
PITCHING MACHINE OUTLET
A
HOME RUN, CIRCUIT AS NOTED. SLASH MARKS
INDICATE MORE THAN 2 CONDUCTORS. PROVIDE
GROUND CONDUCTOR (NOT SHOWN) IN ALL CONDUITS.
EXPOSED RACEWAY
UNDERGROUND RACEWAY
GROUND
BREAKER
GROUND ROD LOCATION - ƒ" X 10 FT COPPERCLAD
WALL MOUNTED JUNCTION BOX
EQUIPMENT AS NOTED
GROUND FAULT INTERRUPTING TYPE 'WR'
W/ "WHILE-IN-USE" COVER
WEATHER PROOF
LED STRIP LIGHT, 3000L, 30W, SURFACE MOUNTED.
PART NUMBER: LITHONIA
CLX L48 3000LM SEF FDL MVOLT GZ10 50K 80CRI WH
TOGGLE SWITCH, 48" AFF
DUPLEX RECEPTACLE, 20A 125VAC, 16" AFF
LEGRAND WIREMOLD OUTDOOR GROUND BOX TYPE 6P
ENCLOSURE, NEMA 5-20R GFCI RECEPTACLE, PART
NUMBER XB814C520C2GY OR PRE-APPROVED EQUAL
LOCKABLE COVER, EXTRA DUTY.
ADJACENT TO SCOREBOARD. PROVIDE METAL
20A 125VAC WEATHER PROOF SWITCH. MOUNT
STORAGE
INFIELD VIEW
BACK VIEW
C o n s u l t i n g
E n g i n e e r s
Date:
Sheet #:
CAD By:
Proj. #:
R E
V
D E
S C
R I P
T I O
N D
A T
E
T if t o o r g ia h id d
M il l
R d
P h o n e
W
W A
T K I N
S E
N G C
O M
W a t k i s o c i a t e s
L L C
C O
A
P
E F x p ir a t io n
O F
C
O M
M I S
S I
O N
E R
S
T I F
T
C
O U
N T
Y
B
O A
F
R
T
H E
I M
P R
O V
E M
E N
T S
P
H A
S E
B
E B
M I L
T O
N
S
P O
R T
S
C
O M
P L
X
W2036-124-01
CADD PLOT
ccobb
10:23
05-JUN-2024
E:\Tifton EB Hamilton Rec Fields - 24014.01\CADD\E2 W2036-124-01.dgn
6/5/24
.0
.4
480Y/277V 3PH 4W
EXISTING DISTRIBUTION PANEL HDA
N O
T
U
D I
B L
E S ƒ
B L
E
P A
T
B L
E
P A
T
B L
E
1NO.8(G)
1"C W/ 3NO.6,
W/ 1NO.6(G)
ƒ"C SCH 80 PVC
1NO.6(G)
2"C W/ 4NO.1,
AMP J-BOX
J-BOX
SCOREBOARD
TRANSFORMER
NEMA 3RSS ENCLOSURE
208Y/120V 3PH 4W
480V 3PH 3W TO
30KVA DRY TYPE
E2
SCALE: 1 / 4 " = 1' - 0" E2
A
A
72" AFF 72" AFF
DUGOUT PLAN - LIGHTING & POWER - TYPICAL
SEE SCHEDULE A
PANEL A
SCALE: 1 / 4 " = 1' - 0" E2
J
20A
A
SCORE BOOTH PLAN - LIGHTING & POWER -TYPICAL
GF
GF
J
SCALE: NTS E2
SEE NOTE G13
SEE NOTE G13 SEE NOTE G13
SCALE: NTS E2
SEE NOTE G13
TO SPEAKERS
125A/3P
GENERAL NOTES, ELECTRICAL PLANS, SCHEDULES
JV
WP
WP
WP
WP
J WP
NOTE G3B
SCOREBOARD
CONTROL TO
NOTE G3A
SCOREBOARD
POWER TO
NOTE G11
J-BOX
AMP
CONTROL RISER DIAGRAM - TYPICAL
NOTE G4
AMPLIFIER
J-BOX AT
NOTE G10
J-BOX
SCOREBOARD
ONE-LINE - FIELDS 1-4
NOTE G14
NEW
50A/3P
NOTE G4
CONSOLE IN SCORE BOOTH
SCOREBOARD CONTROLLER
S C
O R
E B
O A
R
P
E A
K E
R S
Q U I
R
B L
P
E A
K E
R S
Q U I
R
B L
GENERAL NOTES:
MANUFACTURER AND MATCH EXISTING BRANCH FEEDER BREAKER.
MATCH A.I.C. OF PANEL. NEW BREAKER SHALL BE BY PANEL
G14.FURNISH AND INSTALL 50A/3P BREAKER IN EXISTING SPACE.
FIELD 8 VISITOR CKTS LB3-26,28
FIELD 8 HOME CKTS LB3-22,24
FIELD 8 SCORE BOOTH CKTS LB3-18,20H.
FIELD 7 VISITOR CKTS LB3-27,29
FIELD 7 HOME CKTS LB3-23,25
FIELD 7 SCORE BOOTH CKTS LB3-19,21G.
FIELD 6 VISITOR CKTS LB1-12,14
FIELD 6 HOME CKTS LB1-8,10
FIELD 6 SCORE BOOTH CKTS LB1-4,6F.
FIELD 5 VISITOR CKTS LB1-9,11
FIELD 5 HOME CKTS LB1-5,7
FIELD 5 SCORE BOOTH CKTS LB1-1,3E.
FIELD 4 VISITOR CKTS A-24,26
FIELD 4 HOME CKTS A-20,22
FIELD 4 SCORE BOOTH CKTS A-16,18D.
FIELD 3 VISITOR CKTS A-12,14
FIELD 3 HOME CKTS A-8,10
FIELD 3 SCORE BOOTH CKTS A-4,6C.
FIELD 2 VISITOR CKTS A-21,23
FIELD 2 HOME CKTS A-17,19
FIELD 2 SCORE BOOTH CKTS A-13,15B.
FIELD 1 VISITOR CKTS A-9,11
FIELD 1 HOME CKTS A-5,7
FIELD 1 SCORE BOOTH CKTS A-1,3G13.A.
BETWEEN CONTROLLER AND AMPLIFIER.
G12.FIELD COORDINATE CABLES REQUIRED FOR CONNECTION
STERODATA JACKS.
SCORE CONTROLLER FOR BIDDING PURPOSES. PROVIDE 4,‚"
G11.FURNISH CONNECTIONS AS REQUIRED FOR THE AMPLIFIER AND
2 RJ45 JACKS.
CONTROLLER FURNISHED. FOR BIDDING PURPOSES PROVIDE
G10.FURNISH CONTROL/SIGNAL OUTLET COORDINATED WITH SCORE
RACK.
EXISTING PANELS LB1 & LB3 LOCATED ON THIS EQUIPMENT G9.
RACK.
ON THIS 30KVA TRANSFORMER T-A AND PANEL A TO BE LOCATED
EXISTING PANEL HDA LOCATED ON THIS EQUIPMENT RACK. NEWG8.
SCORE BOOTH.
REFER TO DETAIL 3/E2 FOR TYPICAL LAYOUT FOR G7.
WIREMOLD OUTDOOR GROUNDBOX. SEE LEGEND.
WEATHERPROOF GROUND BOX. BASIS OF DESIGN LEGRAND
G6. PITCHING MACHINE OUTLET SHALL INCLUDE FLUSH-IN-GRADE
SCOREBOARD DISCONNECT SWITCH.G5.
CONTROLS.
COORDINATE WITH EQUIPMENT PROVIDED FOR POWER AND DATAG4.
ƒ"W/ 2 CAT6 CABLE.B.
ƒ"C W/ 2NO.12, 1NO.12(G),A.G3.
TRENCHING.
FACILITIES, CONDUITS, OR PIPES DAMAGED BY DIGGING OR
THE CONTRACTOR SHALL REPLACE AND REPAIR ANY UNDERGROUND
REQUEST LOCATE SERVICE PRIOR TO ANY DIGGING OR TRENCHING.G2.
COORDINATE WITH OTHER TRADES AND THE OWNER.
FIELD COORDINATE ALL WORK WITH THE EQUIPMENT FURNISHED.G1.