Water Treatment Trailer - Salient Characteristics.xlsx
XLSX spreadsheet 16 KB Posted
- Attached to
- Fort Bliss, Texas: Mobile Sterilization Unit
- Solicitation number
- PANHCA-26-P-0000031270
- Issued by
-
Department of the Army Medical Command
About this file
This is a Salient Characteristics specification document for a mobile water treatment trailer requirement with a place of performance at WBAMC and a scheduled delivery date of 5/7/2026. The requirement is for one water treatment trailer designed to support mobile sterilization units by providing separate means of treating supply water to meet specific temperature and quality standards for cold water, hot water, and reverse osmosis (RO) final rinse applications.
The trailer must be a complete turnkey system capable of fitting inside a 52-foot tractor trailer with wood flooring and include the following major components: a 60 gpm RO unit with 1a membranes and eight replacement filters; a 2,000-gallon water storage tank; a multibag filter housing with 40-inch filters rated at 0.1 micron absolute (100 filters) and 0.5 micron absolute (100 filters); a 7.5 HP vertical distribution pump with a 10 HP 460V variable frequency drive; a 44-gallon stainless steel bladder tank; a 1-inch globe valve for water blending; water quality monitoring equipment including a GF Signet 9950 TDS meter; a water softening system; four 120V electric heaters; two 120-gallon electric water heaters maintaining 120-140 degrees Fahrenheit; and a 2 gpm recirculating pump. The contractor must provide site visit services to assess existing utilities and available space, complete turnkey installation with interconnection of all equipment to sterilization units, a maintenance plan with on-call personnel support, and monthly water testing. The supplied water must meet strict quality parameters including sediment filtration of 0-5 microns, specific hardness, dissolved solids, alkalinity, pH, conductivity, silica, chloride, and trace metal concentrations for both cold and hot water supplies, with water maintained colorless in appearance.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Sources Sought Notice _Sterilization Units WBAMC.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet3
| Salient Characteristics | ||||
| Palce of Performance: WBAMC Loading Dock | Date:5/7/2026 | |||
| Requirement POC: | Quantity: 1 | |||
| Description: Water treatment Trailer | RP#: | |||
| Summary: Mobile Sterilization trailers will need a seperate means of treating their supply water do to the special requirements needed for the cold water, hot water, and RO for final rinse. | ||||
| # | Description of Minimum Requirement | |||
| and/or Objective | Minimum Requirement | Objective | ||
| 1 | 60 gpm RO unit | 1 | 60 gpm RO unit. Permeate should be able to drain to nearby trench drain. Use | |
| 1a | RO membranes | 8 | Replacement RO Filters | |
| 2 | 2000 Gal Water storage tank | 1 | 2000 gal Water storage tank | |
| 3 | Chemical Injection Quill | 1 | Chemical Injection Quill | |
| 4 | Multibag Filter Housing | 1 | Housing to use 40 inch filters for prefiltering water of sediment and particles. | |
| 4a | Bag filters | 100 | .1 Micron Absolute rating | |
| 4b | Filters | 100 | .5 micron Absolute 40-inch filters | |
| 5 | 7.5 HP Water Pump | 1 | 7.5 HP vertical distribution pump | |
| 6 | VFD | 1 | 10 HP 460 V | |
| 7 | Bladder tank | 1 | 44 Gallon stainless steel vessel w/ bladder | |
| 8 | Globe valve | 1 | 1" for blending water to meet Water quality requirement of sterilization equipment. | |
| 9 | TDS meter | 1 | GF Signet 9950 to measure TDS in mg/l | |
| 10 | Water softner system | 1 | Water softner to soften water going to RO and water Heaters. | |
| 11 | Electric Heaters | 4 | 120 v electric heaters | |
| 12 | 120 Gal Electric Water Heaters | 2 | Hot water supply. Must be able to keep the hot water between 120-140 degrees Faranheit. | |
| 13 | 2 gpm Recirculating pump | 1 | For recirculating hot water | |
| 14 | Containment | N/A | Equipment should fit inside of a 52' tractor trailer with a wood flooring so holes can be made for routing pipe. | |
| 15 | Maintenance | N/A | Maintenance plan should be provided to maintain the individual equipment and the structure. Maintence plan to include on-call personel. | |
| 16 | Installation | N/A | Must include turnkey installation of equipment. Must include connection of equiopment to each other and to the mobile sterilization unit(s). | |
| 17 | Site Visit | N/A | Must include site visit to see availability of exsisting utilites and availble space. | |
| 18 | Monthly water testing | N/A | Monthly water test to test cold water and hot water supply. | |
| 18a | Min Sediment Filtration | MIN-MAX | Cold Water: 0-5 Micron |
Hot Water: 0-5 Micron 18b Total Hardness as CaCo3 MIN-MAX Cold Water: 50-170 ppm CaCo3 Hot Water: 0-17 ppm CaCo3 18c Total Dissovled Solids MIN-MAX Cold Water: 100-170 ppm Hot Water: 50-250 ppm 18d Total Alkalinity as CaCo3 MIN-MAX Cold Water: 70-180 ppm Hot Water: 50-180 ppm 18e pH MIN-MAX Cold Water: 6.5-8.5 Hot Water: 6.5-9.5 18f Conductivity MIN-MAX Cold Water: 0-1000 umhos/cm Hot Water: 40-500 umhos/cm 18g Total Silica MIN-MAX Cold Water: 0-50 ppm Hot Water: 0.1-2.5ppm 18h Chloride MIN-MAX Cold Water: 0-10 ppm Hot Water: 0-10 ppm 18i Cu-Copper MIN-MAX Cold Water: 0-0.1 ppm Hot Water: 0-0.1 ppm 18j Fe-Iron MIN-MAX Cold Water: 0-0.1 ppm Hot Water: 0-0.1 ppm 18k Zn-Zinc MIN-MAX Cold Water: 0-0.1 ppm Hot Water: 0-0.1 ppm 18l Al-Aluminium MIN-MAX Cold Water: 0-0.1 ppm Hot Water: 0-0.1 ppm 18m Mn-Manganese MIN-MAX Cold Water: 0-0.1 ppm Hot Water: 0-0.1 ppm 18n Color/Clarity N/A Water must be colorless
Sheet2
| Cold Utility | Hot Utility | ||||
| Specification | Units | min | max | min | max |
| Min Sediment Filtration | Micron | 0 | 5 | 0 | 5 |
| Total Hardness as CaCo3 | ppm CaCo3 | 50 | 170 | 0 | 17 |
| Total Dissovled Solids | ppm | 100 | 500 | 50 | 250 |
| Total Alkalinity as CaCo3 | ppm | 70 | 180 | 50 | 180 |
| pH | 6.5 | 8.5 | 6.5 | 9.5 | |
| Conductivity | umhos/cm | 0 | 1000 | 40 | 500 |
| Total Silica | ppm | 0 | 50 | 0.1 | 2.5 |
| Chloride | ppm | 0 | 10 | 0 | 10 |
| Cu-Copper | ppm | 0 | 0.1 | 0 | 0.1 |
| Fe-Iron | ppm | 0 | 0.1 | 0 | 0.1 |
| Zn-Zinc | ppm | 0 | 0.1 | 0 | 0.1 |
| Al-Aluminium | ppm | 0 | 0.1 | 0 | 0.1 |
| Mn-Manganese | ppm | 0 | 0.1 | 0 | 0.1 |
| Color/Clarity | Water should be colorless |
File details come from the government source that posted it. Updated .