Pangborn Grating Replacement for IPD South Weymouth SOW.docx
DOCX document 22 KB Posted
- Attached to
- CG IPD S. WEYMOUTH - PANBORN CABINET
- Solicitation number
- 70Z080-21-N-3IE02000
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Sole Source Justification IPD South Weymouth Pangborn Repair.pdf | ||
| FAR CLAUSES.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Statement of Work Pangborn Grating Replacement for IPD South Weymouth
IOD-C
1. GENERAL
1.1 Background
The US Coast Guard is seeking to procure magnesium bar grating, door, closed cell foam deflectors for a Pangborn Blasting cabinet. The Pangborn Blasting Cabinet will be used in many day to day corrosion control requirements by the Industrial Production Detachment (IPD), MA. The currently Pangborn Blasting Cabinet has eroded grating, deflectors, and door due to the blasting shot continuously peening these components. These components for the Pangborn Blasting Cabinet will permit continuing corrosion control blasting operations of different Aids to Navigation buoys, enhancing the organic capabilities of IPD South Weymouth.
1.2 Scope
The manufacturer shall furnish, deliver multiple sets of magnesium grating along with a closed cell foam deflectors and door handle, for the Panborn Blasting Cabinet. These components shall be delivered to the U.S. Coast Guard Base South Weymouth, MA attention to the Work Leader of IPD South Weymouth, MA.
Installation of all components will be conducted by the IPD personnel. All components will be fitted and require no additional modifications, i.e., replace in kind.
The components for Pangborn Blasting Cabinet must include the following:
| Item # |
| Item Name |
| Design Nomenclature |
| Part Number |
| Quantity |
| 1. |
| Deflector |
| 3/4" X 2" OPEN CELL |
| R541022000-2X216 |
| 1 each |
| 2. |
| Bar Grating, Item# 7 |
| Magnesium Bar Grating |
| L150015-ITM7MANG |
| 4 each |
| 3. |
| Grating, Item# 10 |
| Magnesium Grating |
| L150015-ITM10MANG |
| 1 each |
| 4. |
| Door Handle + M/F Part# 9159 |
| Door Handle |
| 44774 |
| 1 each |
2. REQUIREMENTS
2.1 General
The Deflector, Grating, and Door Handle shall be industrial grade production model consisting of coordinated components/materials and certified by the manufacturer. The model shall have been in production for a minimum of three years, and have a minimum one year manufacturer’s warranty. The furnished Deflector, Grating and Door Handle for Pangborn Blasting Cabinet shall have a production date within six months of the delivery date.
Minimal Warranty shall be typed and signed from the manufacturer and be for a minimum of one year from the date of acceptance by the Government.
2.2 Dimension and Construction
The Deflector, Grating and Door Handle for Pangborn Blasting Cabinet shall be constructed in and built to operate in adherence of all local, state, and federal regulations. These are a replace in kind components fitted for the Pangborn Blasting Cabinet. The Manufacturer must ensure the application of all references in section 2.6 of this Statement of Work.
2.3 Delivery Location
Location IPD Base South Weymouth, MA
The U.S. Coast Guard IPD South Weymouth is located at 65 Trotter Rd.
South Weymouth, MA 02190. Arrangements for delivery shall be made with the IPD Industrial Manager at (781) 340-1373. Delivery times shall be between the hours of 8:00 AM to 3:00 PM local time, Monday through Friday inclusive. Unloading as well as installation of all components will be for Pangborn Blasting Cabinet shall be the responsibility of the IPD South Weymouth.
2.4 References
The Deflector, Grating and Door Handle for Pangborn Blasting Cabinet shall be in accordance with the standards and specifications of the referenced technical organizations for the construction methods, materials, application and environment as applicable. These may include but not be limited to:
a. ISO Standards.
b. American National Standards Institute (ANSI).
c. National Electrical Manufacturers Association (NEMA).
d. All applicable OSHA standards.
2.5 Submittals and Approvals
Submittals shall be delivered to the Government Contracting Officer within seven (7) Calendar days after the award of the contract.
3. ACCEPTANCE
3.1 On-site Testing, Training, and Operations and Maintenance Manuals
The Deflector, Grating and Door Handle for the Pangborn Blasting Cabinet will be installed by IPD personnel and all components shall fit without modification. Any components that do not fit as required shall be returned to the vendor for replacement and no additional shipping cost.
4. PERIOD OF PERFORMANCE
The period of performance is 90 calendar days from date of contract award. If applicable, award of Optional Item is expected to take place within 45 calendar days of award of base items.
4.1 Contracting Officer’s Representative
a. COR information will be provided at time of award.
File details come from the government source that posted it. Updated .