PA062-Meadville-A2-CSS 88852-Technical Exhibit-Replace Exterior Doors.pdf

PDF 5 MB Posted

Attached to
CONSTRUCTION - Multiple Projects - PA & NY Federal contract opportunity
Solicitation number
W15QKN-24-R-5049
Issued by
Department of the Army Materiel Command Contracting Command Picatinny Arsenal

About this file

This document appears to be a technical exhibit for replacing exterior doors at the Crawford County Memorial USARC building in Meadville, PA. The key details are:

The exhibit provides drawings and specifications for replacing the classroom doors and front entry storefront at the facility. The classroom doors and frames are to be replaced with new galvanneal undercoating and painted in a dark bronze color. The front entry storefront will also be upgraded, with the interior and exterior steel frames stripped to bare metal, rust removed, and a rust inhibitor applied before painting in the same dark bronze color. The existing blast-resistant film is to remain in place, with any damaged areas replaced. Additionally, a new covered entryway 12-feet wide and 5.5-feet deep will be constructed, with the roof and facia panels in a matching dark bronze color.

This technical exhibit appears to be related to Solicitation Number W15QKN-24-R-5049 for multiple construction projects in Pennsylvania and New York. The solicitation is in the pre-solicitation phase, and further details on the response process and award timeline are to be provided when the full solicitation is released.

View the file

Other files for this federal contract opportunity

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DPW - CAD / GIS BRANCH

DMW 1 OF 2

SHEET:DATE:FIELD VERIFIED:CHECKED:DRAWN:

99th REGIONAL SUPPORT COMMAND

0 10’ 20’ 40’

GRAPHIC SCALE

114A

485 sf

80 sf

80 sf

210 sf

114B

710 sf

380 sf

130 sf

120 sf

450 sf

210 sf

240 sf

880 sf

260 sf

280 sf

160 sf

30 sf

290 sf

330 sf

120 sf

180 sf

230 sf

320 sf

150 sf

300 sf

200 sf

960 sf

CORRIDOR

2,840 sf

JD SK 18JUL14

MAIN FLOOR PLAN

PA062 (42890)

MEADVILLE, PA

CRAWFORD COUNTY MEM USARC

ASSEMBLY

UNIT STORAGE

OFFICE

SUPPLY

J.C.

CHAIR STOR.

MAINT. /

UNIT STORAGE

M. LOCKERS

W. LOCKERS

STORAGE

TRAINING AIDS /

OPERATIONS

ADMIN. - TRAINING /

OFFICER

COMMANDING

ADMIN. /

RETENTION CENTER

LRNG.

CLASSROOM

LIBRARY /

CLASSROOMS

TOILET

W.

M. TOILETCIVIL TECH.

ADMIN. OFFICE /

DISTR. / REPRODUCTION

SECURITY

COMM.

ARMS VAULT

MECH. EQUIP.

FOOD STOR.

FOOD PREP.

SCULLERY

(BUILDING TOTAL 11,916 sf)

MEADVILLE, PA

1151 MORGAN STREET EXTENSION

PA062 (42890) / USARC BUILDING

CUI//SP-PROCURE//LDC

CUI//SP-PROCURE//LDC

right Text Box Location of work right Text Box Front Entrance right Text Box Parking Lot is located on this side of the building.

right Line right Line right Text Box Classroom doors & location Covered Entry to be installed

1032794242121005.mil Rectangle

Classroom Doors

• Replace both doors and frames

• New doors and frame to be galvanneal undercoating and painted a dark bronze color to match surroundings.

• Door dimensions:

• 3-foot by 7-foot

• Additional details are listed in the SOW.

CUI//SP-PROCURE//LDC

Wood Construction Steel overlay Covered Entryway

12’ Wide

1’ 1’

18" Piers

5-1/2’ Depth

• Dimensions 12-foot wide by 5-1/2-foot in depth.

• Cover shall only extend approximately 1-foot beyond the edge of the brick.

• Roof panel and font facia panels shall be steel panels that are a dark bronze color to match the surroundings.

• Light fixture “A” shall become an Emergency Egress light fixture.

Light fixture “B” shall be the power supply to power a overhead surface mounted entry light fixture that is photocell operated.

Piers shall be 18-inches in diameter and 5-linear-feet in height. (3-foot below ground and 2-foot above ground).

A B

4”x6” post, Wood, Treated

Store Front Entry

Side Panels:

• Interior and exterior steel frame shall be stripped to bare metal.

• All rust shall be removed, and a rust inhibitor shall be applied.

• Painted a dark bronze color to match surroundings.

• Blast resistant film shall remain in place. Any film damaged while completing the upgrade shall be replaced.

Main Panel:

• Replace Panel - new doors and frame to be galvanneal undercoating and painted a dark bronze color to match surroundings.

• Size 8-foot wide by 9-foot high

• Door size 3-foot wide by 7-foot high

• All glass to be covered with a blast resistant film.

Main PanelSide Side

CUI//SP-PROCURE//LDC

CUI//SP-PROCURE//LDC

1032794242121005.mil Inserted Text

1032794242121005.mil Text Box **NOTE** Additional requirements for the storefront entry are listed in the SOW.

PA062_FP_01-FirstFloor_July2014
PA062_FP_02-OMS_July2014
Cover for Entryway.pdf
Wood Construction Steel overlay Covered Entryway
Store Front� Entry
Classroom Doors.pdf
Classroom Doors

File details come from the government source that posted it. Updated .