PA062-Meadville-A2-CSS 88852-Technical Exhibit-Replace Exterior Doors.pdf
PDF 5 MB Posted
- Attached to
- CONSTRUCTION - Multiple Projects - PA & NY Federal contract opportunity
- Solicitation number
- W15QKN-24-R-5049
About this file
This document appears to be a technical exhibit for replacing exterior doors at the Crawford County Memorial USARC building in Meadville, PA. The key details are:
The exhibit provides drawings and specifications for replacing the classroom doors and front entry storefront at the facility. The classroom doors and frames are to be replaced with new galvanneal undercoating and painted in a dark bronze color. The front entry storefront will also be upgraded, with the interior and exterior steel frames stripped to bare metal, rust removed, and a rust inhibitor applied before painting in the same dark bronze color. The existing blast-resistant film is to remain in place, with any damaged areas replaced. Additionally, a new covered entryway 12-feet wide and 5.5-feet deep will be constructed, with the roof and facia panels in a matching dark bronze color.
This technical exhibit appears to be related to Solicitation Number W15QKN-24-R-5049 for multiple construction projects in Pennsylvania and New York. The solicitation is in the pre-solicitation phase, and further details on the response process and award timeline are to be provided when the full solicitation is released.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| PA027-Farrell-A2-CSS 94030-Fire Suppression Technical Exhibit-Repair Kitchen Hood System.pdf | ||
| NY010-Amherst-A2-CSS 88762-SOW-Repair HVAC in Training Room.docx | DOCX document | |
| PA027-Farrell-A2-CSS 94030-SOW-Repair Kitchen Hood System-V3.docx | DOCX document | |
| PA062-Meadville-A2-CSS 88852-SOW-Replace Exterior Doors.docx | DOCX document | |
| NY010-Amherst-A2-CSS 88762-Technical Exhibit-Repair HVAC in Training Room.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DPW - CAD / GIS BRANCH
DMW 1 OF 2
SHEET:DATE:FIELD VERIFIED:CHECKED:DRAWN:
99th REGIONAL SUPPORT COMMAND
0 10’ 20’ 40’
GRAPHIC SCALE
114A
485 sf
80 sf
80 sf
210 sf
114B
710 sf
380 sf
130 sf
120 sf
450 sf
210 sf
240 sf
880 sf
260 sf
280 sf
160 sf
30 sf
290 sf
330 sf
120 sf
180 sf
230 sf
320 sf
150 sf
300 sf
200 sf
960 sf
CORRIDOR
2,840 sf
JD SK 18JUL14
MAIN FLOOR PLAN
PA062 (42890)
MEADVILLE, PA
CRAWFORD COUNTY MEM USARC
ASSEMBLY
UNIT STORAGE
OFFICE
SUPPLY
J.C.
CHAIR STOR.
MAINT. /
UNIT STORAGE
M. LOCKERS
W. LOCKERS
STORAGE
TRAINING AIDS /
OPERATIONS
ADMIN. - TRAINING /
OFFICER
COMMANDING
ADMIN. /
RETENTION CENTER
LRNG.
CLASSROOM
LIBRARY /
CLASSROOMS
TOILET
W.
M. TOILETCIVIL TECH.
ADMIN. OFFICE /
DISTR. / REPRODUCTION
SECURITY
COMM.
ARMS VAULT
MECH. EQUIP.
FOOD STOR.
FOOD PREP.
SCULLERY
(BUILDING TOTAL 11,916 sf)
MEADVILLE, PA
1151 MORGAN STREET EXTENSION
PA062 (42890) / USARC BUILDING
CUI//SP-PROCURE//LDC
CUI//SP-PROCURE//LDC
right Text Box Location of work right Text Box Front Entrance right Text Box Parking Lot is located on this side of the building.
right Line right Line right Text Box Classroom doors & location Covered Entry to be installed
1032794242121005.mil Rectangle
Classroom Doors
• Replace both doors and frames
• New doors and frame to be galvanneal undercoating and painted a dark bronze color to match surroundings.
• Door dimensions:
• 3-foot by 7-foot
• Additional details are listed in the SOW.
CUI//SP-PROCURE//LDC
Wood Construction Steel overlay Covered Entryway
12’ Wide
1’ 1’
18" Piers
5-1/2’ Depth
• Dimensions 12-foot wide by 5-1/2-foot in depth.
• Cover shall only extend approximately 1-foot beyond the edge of the brick.
• Roof panel and font facia panels shall be steel panels that are a dark bronze color to match the surroundings.
• Light fixture “A” shall become an Emergency Egress light fixture.
Light fixture “B” shall be the power supply to power a overhead surface mounted entry light fixture that is photocell operated.
Piers shall be 18-inches in diameter and 5-linear-feet in height. (3-foot below ground and 2-foot above ground).
A B
4”x6” post, Wood, Treated
Store Front Entry
Side Panels:
• Interior and exterior steel frame shall be stripped to bare metal.
• All rust shall be removed, and a rust inhibitor shall be applied.
• Painted a dark bronze color to match surroundings.
• Blast resistant film shall remain in place. Any film damaged while completing the upgrade shall be replaced.
Main Panel:
• Replace Panel - new doors and frame to be galvanneal undercoating and painted a dark bronze color to match surroundings.
• Size 8-foot wide by 9-foot high
• Door size 3-foot wide by 7-foot high
• All glass to be covered with a blast resistant film.
Main PanelSide Side
CUI//SP-PROCURE//LDC
CUI//SP-PROCURE//LDC
1032794242121005.mil Inserted Text
1032794242121005.mil Text Box **NOTE** Additional requirements for the storefront entry are listed in the SOW.
| PA062_FP_01-FirstFloor_July2014 |
| PA062_FP_02-OMS_July2014 |
| Cover for Entryway.pdf |
| Wood Construction Steel overlay Covered Entryway |
| Store Front� Entry |
| Classroom Doors.pdf |
| Classroom Doors |
File details come from the government source that posted it. Updated .