This memorandum is a detailed item description for two industrial parts washers requested by the 76th PMXG at Tinker Air Force Base. The specification requires heavy-duty parts washers with specific volumetric and operational requirements, including an internal diameter of 60-72 inches, internal height of 48-60 inches, and stainless steel construction. Key operational specifications include an operating temperature range of 90°F to 190°F, adjustable cleaning cycle duration of 5-30 minutes, hot water flush capabilities, forced air drying, and compatibility with overhead hoist loading/unloading. Additional requirements include an integrated oil skimmer system, emergency stop conforming to NFPA 79, and comprehensive tooling package for secure part fixturing. The document also mandates specific data plates (lubrication, nameplate, IUID, and warranty) with corrosion-resistant, engraved text, and requires the contractor to provide installation telephone support and handle shipping to Tinker AFB, Oklahoma.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| CSS Industrial Parts Washers - Q A_ Amendment 1_ 10 July 2025.pdf | ||
| CSS Industrial Parts Washer_7 July 2025.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DEPARTMENT OF THE AIR FORCE
HEADQUARTERS AIR FORCE SUSTAINMENT CENTER (AFMC)
TINKER AIR FORCE BASE OKLAHOMA
2 May 2025
MEMORANDUM FOR RECORD
SUBJECT: Item Description, P25-008 Industrial Parts Washer
The 76th PMXG is requesting utilization of funds for the purchase of two (2) Parts Washers. The requested equipment item descriptions/specifications are outlined below.
Quantity two (2) industrial parts washers designed for heavy-duty cleaning and capable of handling workload demands.
1. Volumetric Capacity & Dimensions:
• Internal Diameter: Minimum 60 inches, maximum 72 inches.
• Internal Height: Minimum 48 inches, maximum 60 inches.
2. Material & Construction:
• All internal components in contact with cleaning fluid (nozzles, walls, pumps, etc.) shall be constructed of stainless steel for corrosion resistance and longevity.
• Exterior finish painted lead-free according to manufacturer's commercial practice.
• Ventilated and equipped with compliant outlets.
• Integrated, programmable Automatic Oil Skimmer system for continuous removal of free-floating oils and contaminants. The parts washers must be configured to run without the oil skimmer turned on, if necessary.
• Measuring Devices shall be graduated in both US customary and SI units.
• Secure Mounting System to keep parts stationary throughout wash cycle
• Emergency Stop: Conforming to NFPA 79, readily accessible from normal operating locations.
3. Operational Requirements:
• Operating Temperature: 90°F to 190°F (TO 2-1-111).
• Cleaning Cycle Duration: Adjustable from 5 to 30 minutes in 1-minute increments, with capability for cycles exceeding 30 minutes (TO 2-1-111).
• Rinsing & Drying System (TO 2-1-111):
o Hot Water Flush: 150°F to 200°F, continuing until part temperature reaches rinse water temperature.
o Forced Air Drying: Filtered air at a maximum pressure of 30 psig, activated automatically if residual water remains.
• Designed for safe and efficient loading/unloading with an overhead hoist.
• Easily accessible grease fittings for all bearings and lubrication points. Detailed lubrication data (viscosity, type, specifications, etc.) to be provided.
• Comprehensive tooling package to include sets of clamps, brackets, and blocks for secure fixturing of various part geometries, compatible with cleaning solutions and operating temperatures.
4. Data Plates: Corrosion-resistant, with engraved/etched/embossed/stamped English text.
• Lubrication Plate: Detailed lubrication information (points, intervals, type, viscosity, specifications).
• Nameplate: Compliant with NFPA 79, including manufacturer information, model/serial numbers, electrical specifications, and diagram numbers.
• IUID Plate: Compliant with MIL-STD-130N, including nomenclature, CAGE code, manufacturer, model/serial numbers, date of manufacture, and contract number.
• Warranty Plate: Indicating "WARRANTED ITEM" and expiration date.
5. Installation support: provide telephone support during in-house installation.
6. Shipping:
• Contractor responsible for crating, preservation, transportation, and delivery to Tinker AFB, OK.