This statement of work outlines pharmacy modular casework requirements for the Department of Veterans Affairs Redding Outpatient Clinic in Redding, California. Key requirements include pharmacy storage shelves, workstations, and narcotic storage cabinets in various sizes and configurations. Products will be purchased through a request for quotes set-aside for verified service-disabled veteran-owned small businesses. Delivery is required by late January to late February 2021 to the VA clinic located at 3455 Knighton Road in Redding. Finishes and installation will be coordinated with the VA. The statement of work provides detailed product specifications, dimensions, materials, and quality standards for the modular casework.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C77621Q0006_1.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
General Conditions and Statement of Work Package 002: Pharmacy Modular Casework VA Redding Outpatient Clinic VA Northern California Healthcare System Redding VA Clinic 3455 Knighton Road Redding, CA 96002
Redding Outpatient Clinic Initial Outfitting, Transition & Activation Project Equipment Package General Conditions and Statement of Work Package #002 Pharmacy Modular Casework
1 Introduction The VA Redding Outpatient Clinic (VA ROC ) has a requirement to purchase Pharmacy Modular Casework with an authorized vendor to supply and deliver the item(s) identified in Table 1 below. This requirement is in support of a brand name or equal requirement. See FAR Clause 52.211-6 – Brand Name or Equal (AUG 1999) for additional information. See attachments for salient characteristics. This requirement is in support of the activation of the VA ROC . Item(s) are to be delivered to the location specified in section 2.4.1.
Table 1 – Package Items Summary
| Item Number |
| Item Description |
| Quantity |
| E0609A |
| Shelf Unit, Pharmacy, Wall Mtd, 84"Hx34"Wx12"D |
| 3 |
| E0609C |
| Shelf Unit, Pharmacy, 84"H x 24"W x 12"D |
| 5 |
| E0609D |
| Shelf Unit, Pharmacy, 84"H x 36"W x 12"D |
| 2 |
| E0618A |
| Shelves, Pharmacy, Wall Mtd, Tall, 84"Hx36"Wx18"D |
| 7 |
| E0618B |
| Shelves, Pharmacy, 84"H x 36"W x 24"D |
| 16 |
| E0618C |
| Shelves, Pharmacy, 36"W x 36"D x 84"H |
| 3 |
| U2000 |
| Casework, Modular, Pharmacy, Workstation |
| 1 |
| U2001 |
| Casework, Modular, Pharmacy, Transaction Window Station |
| 1 |
| U2002 |
| Casework, Modular, Pharmacy, Order Entry Station |
| 1 |
| U2003 |
| Casework, Modular, Pharmacy Mail Order Station |
| 1 |
| U2004 |
| Casework, Modular, Pharmacy, Receiving Station |
| 1 |
| U2005 |
| Casework, Modular, Pharmacy, Automation Filling Station South Wall |
| 1 |
| U2006 |
| Casework, Modular, Pharmacy, Automation Filling Station West |
| 1 |
| U2007 |
| Casework, Modular, Pharmacy, 48"W x 24"D x 39"H |
| 1 |
| U2008 |
| Casework, Modular, Pharmacy, Narcotics East |
| 1 |
| U2009 |
| Casework, Modular, Pharmacy, Narcotics South |
| 1 |
| U2009B |
| Casework, Modular, Pharmacy, 72"w x 39"H x 36D Cart |
| 1 |
| U2010 |
| Casework, Modular, Pharmacy, Check and Fill Island |
| 1 |
| U2011 |
| Casework, Modular, Pharmacy, 72"W x 36"D x 39"H |
| 1 |
2 General Conditions
2.1 Site Address
2.1.1 The address of the VA Redding Outpatient Clinic is listed below. Additional information on delivery is located in section 2.4.
Redding Outpatient Clinic Initial Outfitting, Transition and Activation Project 3455 Knighton Road Redding, CA 96002
2.2 Delivery Schedule
Items shall be delivered no earlier than the estimated delivery start date and no later than the delivery end date listed in Table 2 below.
| Table 2 – Anticipated Building Outfitting Schedule |
| Building Name |
| Building # & Letter |
| Acronym |
| Est. Delivery Start Date |
| Est. Delivery End Date |
VA Redding Outpatient Clinic
| VA ROC |
| 2021-01-31 |
| 2021-02-28 |
2.3 Schedule and Order Management
2.3.1 The above delivery schedule is based upon the current construction schedule, which is subject to change. The vendor shall not increase prices for a change in delivery date for up to 30+ days due to construction delays.
2.3.2 The awardees actual delivery dates will be confirmed by VA upon award.
2.3.3 Post-award the vendor will coordinate delivery prior to beginning any work (see section 2.4). Once the dates have been confirmed, modifications to the schedule are subject to written approval by the VA POC and the vendor. Schedule changes that are beyond the dates specified in the contract will require approval by the Contracting Officer and a contract modification.
2.4 Delivery and Receiving
2.4.1 Delivery and receipt of the proposed items is anticipated to be directed to the location identified below. Confirmation of delivery location will be provided by the VA POC post-award. Delivery must be coordinated with VA Logistics POC Amy Carr, 720-908-5436 prior to any attempts at delivery. Any item that has not been coordinated will be turned away and any additional charges will be the responsibility of the sender/transportation company.
☒ VA Redding Outpatient Clinic (Direct Delivery to address detailed in paragraph 2.1.1)
2.4.2 Delivery shall be freight on board (FOB) – Destination.
2.4.3 The vendor is required to define the need for a staging area to accommodate item delivery, if needed. Post-award, this information will be confirmed with the vendor.
2.4.4 The delivery of items identified in this document shall take place during normal business hours which are defined as: 0800 to 1630 (i.e.: 8:00am to 4:30pm Pacific Time), Monday through Friday, and excluding Federal Holidays.
2.4.5 Delivery trucks will not be permitted to remain at the loading dock. Trucks shall be unloaded, moved from the dock, and then brought back to the dock if required to haul out any waste, tools, or excess materials.
2.4.6 Labeling of delivered items shall include the awarded contract number and VA purchase order number for identification and reference upon receipt of product.
2.5 Use of Warehouse
2.5.1 If the vendor requires the use of the Government’s activation contractor’s warehouse to meet the requirements of this contract the vendor must provide a certificate of insurance prior to the delivery and offloading of the item(s). This insurance certificate must be completed and presented to the activation contractor prior to delivery.
2.5.2 The vendor shall communicate through the VA POC any required coordination requirements.
2.6 Clean Up and Disposal
2.6.1 There are no dumpsters available for vendor use.
2.6.2 The removal of waste and/or excess material shall be conducted through the loading dock area. Delivery trucks and/or other vendor vehicles will not be permitted to remain at the loading dock. Vehicles will need to be brought back to the dock if required to remove any waste, tools, or excess materials.
2.7 Deliverables
2.7.1 The vendor shall provide CAD drawings (including shop drawings) and specifications for site prep for their product as required.
2.7.2 The vendor shall provide a completed VA Form 6550 with submittal documents for any and all item(s) that may connect to the VA network and medical devices that store sensitive patient information.
2.8 Assembly and Installation [ ☒ is is not required]
2.8.1 The vendor is required to manage and coordinate installation at the VA ROC with the VA POC.
2.8.2 On-site assembly and installation of items, and performance of services identified in this document shall take place during normal business hours which are defined as: 0800 to 1630 (i.e.: 8:00am to 4:30pm Pacific Time), Monday through Friday, and excluding Federal Holidays.
2.8.3 The vendor is required to define the need for a staging area to accommodate item assembly and installation, if needed. Post-award, this information will be confirmed with the vendor.
2.8.4 The vendor is required to provide tools, labor and materials to complete assembly and installation of the items detailed in this document.
2.8.5 The vendor shall protect all finished spaces and surfaces as required from delivery and installation damage. The vendor shall use covering and protection to the extent necessary to prevent damage to finished spaces. Any damage occurred during delivery and installation is the responsibility of the vendor. The vendor will be responsible for paying for and repairing any damage or noted deficiencies to finished spaces and surfaces that occur as a result of the vendor’s (or associated sub-contractors) installation.
2.8.6 During the entire duration of assembly and installation, the vendor will have a competent representative on-site as the vendor’s contact, and to serve as the interface between the vendor and VA ROC . On-site representative can be the installer. All instructions provided from COR to the representative will be binding as if given to the vendor’s main contact. The COR may provide specific instructions, however, only the Contracting Officer may change the terms or conditions of the contract.
2.9 Training [ is ☒ is not required]
2.9.1 The vendor shall coordinate through the VA POC to provide a hands-on training session to staff selected by the VA. Training shall be completed within 45 days after final installation of equipment. The vendor will record the training and provide a electronic copy of the training to the VA POC for VA to use to train additional personal at a future date. In addition, the vendor shall provide additional training documents to the VA POC for training additional persons at a future date.
2.10 Standard Warranty
2.10.1 The products shall be covered by vendor’s standard warranty terms and provisions, provided, however that the warranty coverage shall be no less than the following:
2.10.2 The Vendor shall provide a warranty certificate/form stating the warranty period, terms, and information required to initiate the warranty.
2.10.3 The warranty period set forth therein shall run for one year following the first day of use at VA ROC.
2.10.4 The vendor shall extend such warranty directly to the customer as if such customer had purchased the Products directly from the vendor.
2.10.5 The vendor shall warrant the products against defects in material and workmanship under normal use and service, repair or replace at vendor’s cost any defective Product (or issue a credit or refund, as the case may be, based on the purchase price paid therefor); and
2.10.6 The vendor shall pay (or refund the amount of) all freight and shipping charges for any defective Products returned under this paragraph.
2.11 Use of Premises
2.11.1 If during the performance of this contract, work will be carried out on VA ROC premises, the vendor shall perform all work in such a manner that will cause a minimum interference with VA ROC operations and the operations of other contractors on the premises.
2.11.2 The vendor shall communicate through the VA POC any required coordination requirements with the General Construction contractor prior to and during delivery and installation activities.
2.11.3 The project may be an active construction site during delivery and installation. The vendor shall take all necessary precautions to protect the premises and all persons and property therein from damage or injury. The vendor shall assume responsibility for taking precautions for the vendor's (and associated subcontractors’) employees, agents, licensees, and permittees. The vendor shall abide by any safety requirements imposed by the GC (e.g. hard hats, safety vests).
Redding Outpatient Clinic 3455 Knighton Road Redding, CA 96002
General Conditions and Statement of Work Pharmacy Modular Casework
| Redding CBOC Project |
| E0609A |
3455 Knighton Road Redding, CA 96002
| Project: Redding CBOC Project |
| Issue Date: October 2020 |
Total Quantity: 3 ☒ Finish Sample Required if Checked ☒ Manufacturer Certified Installation Required if Checked Item Name: Shelf Unit, Pharmacy, Wall Mtd, 84"Hx34"Wx12"D Brand Name or Equal: Modular Pharmacy Solutions | Unspecified | null Width: 34 in. Depth: 12 in. Height: 80 - 84 in.
| Salient Characteristics: |
| Main Image: |
Pharmacy storage shelves used to store pharmaceutical drug containers and other small containers needed throughout the pharmacy. Overall dimensions (including toe kick) 84" high (+/-4") x 34" wide x 12" deep.
ADDITIONAL REQUIREMENTS ARE AS FOLLOWS:
Materials:
*Core material shall be particle board conforming to CS 236-66 45 pound “B” density, Class 1 of Type 1 *Laminated plastic for general construction shall be 1/32” or 1/16” thick high-pressure type *All top, side and bottom panels and shelf panels shall be laminated with high pressure laminate including cabinet interiors in the same color and finish as selected for exposed surfaces.
*Adhesive for laminate shall be urea-formaldehyde resin free.
*Edge moldings shall be PVC edge band and appear on all edges of the casework that are visibly exposed. Molding shall be the same thickness as shelf when on shelf, counter molding shall be 1-1/4” wide and flush with worksurface.
*Shelving shall be 3/4" thick core with laminate on both sides.
*Casework shall be fabricated using flush construction methods with modern machinery.
*Casework shall be delivered fully constructed and ready for installation. Each unit shall be self-supporting and permit relocation. The sharing of component parts to form a rigid, modular, free-standing assembly shall not be acceptable.
Features:
*Unit shall be securable to the wall via mounting hardware *All shelves shall be 3/4” thick core with high pressure laminate on both sides.
*All shelves noted as being sloping shall also adjust to a flat position. Adjustable vertically on 1" centers and from horizontal to 15, 30, and 45-degree slope down.
*All shelves shall be completely reversible with retainer lips being turned up, down, or to the back as required for use.
*All top, side, and bottom panels and shelf panels shall be laminated with high pressure laminate including cabinet interiors in the same color and finishes as selected for the exposed surfaces. All cabinet backs will have HPL on interior surface.
*Unit shall have a non-adjustable bottom shelf that is the base of the cabinet positioned on top of the toe kick *Unit shall have a 4" toe kick.
*Unit shall have 7 adjustable shelves.
Quality Assurance:
*Manufacturer must have a minimum of 5 years experience in providing manufactured casework for similar types of projects. Manufacturer facility must be certified to premium grade by the AWI Quality Certification Program.
*All pharmacy casework included in this specification shall be made by a pharmacy casework manufacturer who is a specialist in the design and manufacture of pharmacy casework and has in operation, a factory adequate in size, with facilities for and devoted to the manufacture of the equipment he or his distributor proposes to supply. This requirement is stated for the Owners protection to eliminate any divided responsibility and to ensure that all completed assemblies shall be in harmony and uniform in design, color, type of hardware, etc., for the completed facility/installation.
*A minimum of five years experience in the design, sale, manufacture, shipping, and installation of the quality and type of pharmacy casework specified herein shall be required.
Finishes:
*Casing, shelves, end panels- Laminate Wilsonart Fusion Maple 7909-60 with PVC edge banding to match laminate. Final finishes to be approved by VA interior design prior to purchase.
| Redding CBOC Project |
| E0609C |
3455 Knighton Road
| Project: Redding CBOC Project |
| Issue Date: October 2020 |
Total Quantity: 5 ☒ Finish Sample Required if Checked ☒ Manufacturer Certified Installation Required if Checked
Item Name: Shelf Unit, Pharmacy, 84"H x 24"W x 12"D Brand Name or Equal: Modular Pharmacy Solutions | Unspecified | null Width: 24 in. Depth: 12 in. Height: 80 - 84 in.
| Salient Characteristics: |
| Main Image: |
Pharmacy storage shelves used to store pharmaceutical drug containers and other small containers needed throughout the pharmacy. Overall dimensions (including toe kick) 84" high (+/-4") x 24" wide x 12" deep.
ADDITIONAL REQUIREMENTS ARE AS FOLLOWS:
Materials:
*Core material shall be particle board conforming to CS 236-66 45 pound “B” density, Class 1 of Type 1 *Laminated plastic for general construction shall be 1/32” or 1/16” thick high-pressure type *All top, side and bottom panels and shelf panels shall be laminated with high pressure laminate including cabinet interiors in the same color and finish as selected for exposed surfaces.
*Adhesive for laminate shall be urea-formaldehyde resin free.
*Edge moldings shall be PVC edge band and appear on all edges of the casework that are visibly exposed. Molding shall be the same thickness as shelf when on shelf, counter molding shall be 1-1/4” wide and flush with worksurface.
*Shelving shall be 3/4" thick core with laminate on both sides.
*Casework shall be fabricated using flush construction methods with modern machinery.
*Casework shall be delivered fully constructed and ready for installation. Each unit shall be self-supporting and permit relocation. The sharing of component parts to form a rigid, modular, free-standing assembly shall not be acceptable.
Features:
*Unit shall be securable to the wall via mounting hardware *All shelves shall be 3/4” thick core with high pressure laminate on both sides.
*All shelves noted as being sloping shall also adjust to a flat position. Adjustable vertically on 1" centers and from horizontal to 15, 30, and 45-degree slope down.
*All shelves shall be completely reversible with retainer lips being turned up, down, or to the back as required for use.
*All top, side, and bottom panels and shelf panels shall be laminated with high pressure laminate including cabinet interiors in the same color and finishes as selected for the exposed surfaces. All cabinet backs will have HPL on interior surface.
*Unit shall have a non-adjustable bottom shelf that is the base of the cabinet positioned on top of the toe kick *Unit shall have a 4" toe kick.
*Unit shall have 7 adjustable shelves.
Quality Assurance:
*Manufacturer must have a minimum of 5 years experience in providing manufactured casework for similar types of projects. Manufacturer facility must be certified to premium grade by the AWI Quality Certification Program.
*All pharmacy casework included in this specification shall be made by a pharmacy casework manufacturer who is a specialist in the design and manufacture of pharmacy casework and has in operation, a factory adequate in size, with facilities for and devoted to the manufacture of the equipment he or his distributor proposes to supply. This requirement is stated for the Owners protection to eliminate any divided responsibility and to ensure that all completed assemblies shall be in harmony and uniform in design, color, type of hardware, etc., for the completed facility/installation.
*A minimum of five years experience in the design, sale, manufacture, shipping, and installation of the quality and type of pharmacy casework specified herein shall be required.
*Casing, shelves, end panels- Laminate Wilsonart Fusion Maple 7909-60 with PVC edge banding to match laminate. Final finishes to be approved by VA interior design prior to purchase.
| Redding CBOC Project |
| E0609D |
3455 Knighton Road
| Project: Redding CBOC Project |
| Issue Date: October 2020 |
Total Quantity: 2 ☒ Finish Sample Required if Checked ☒ Manufacturer Certified Installation Required if Checked
Item Name: Shelf Unit, Pharmacy, 84"H x 36"W x 12"D Brand Name or Equal: Modular Pharmacy Solutions | Unspecified | null Width: 36 in. Depth: 12 in. Height: 80 - 84 in.
| Salient Characteristics: |
| Main Image: |
Pharmacy storage shelves used to store pharmaceutical drug containers and other small containers needed throughout the pharmacy. Overall dimensions (including toe kick) 84" high (+/-4") x 36" wide x 12" deep.
ADDITIONAL REQUIREMENTS ARE AS FOLLOWS:
Materials:
*Core material shall be particle board conforming to CS 236-66 45 pound “B” density, Class 1 of Type 1 *Laminated plastic for general construction shall be 1/32” or 1/16” thick high-pressure type *All top, side and bottom panels and shelf panels shall be laminated with high pressure laminate including cabinet interiors in the same color and finish as selected for exposed surfaces.
*Adhesive for laminate shall be urea-formaldehyde resin free.
*Edge moldings shall be PVC edge band and appear on all edges of the casework that are visibly exposed. Molding shall be the same thickness as shelf when on shelf, counter molding shall be 1-1/4” wide and flush with worksurface.
*Shelving shall be 3/4" thick core with laminate on both sides.
*Casework shall be fabricated using flush construction methods with modern machinery.
*Casework shall be delivered fully constructed and ready for installation. Each unit shall be self-supporting and permit relocation. The sharing of component parts to form a rigid, modular, free-standing assembly shall not be acceptable.
Features:
*Unit shall be securable to the wall via mounting hardware *All shelves shall be 3/4” thick core with high pressure laminate on both sides.
*All shelves noted as being sloping shall also adjust to a flat position. Adjustable vertically on 1" centers and from horizontal to 15, 30, and 45-degree slope down.
*All shelves shall be completely reversible with retainer lips being turned up, down, or to the back as required for use.
*All top, side, and bottom panels and shelf panels shall be laminated with high pressure laminate including cabinet interiors in the same color and finishes as selected for the exposed surfaces. All cabinet backs will have HPL on interior surface.
*Unit shall have a non-adjustable bottom shelf that is the base of the cabinet positioned on top of the toe kick *Unit shall have a 4" toe kick.
*Unit shall have 7 adjustable shelves.
Quality Assurance:
*Manufacturer must have a minimum of 5 years experience in providing manufactured casework for similar types of projects. Manufacturer facility must be certified to premium grade by the AWI Quality Certification Program.
*All pharmacy casework included in this specification shall be made by a pharmacy casework manufacturer who is a specialist in the design and manufacture of pharmacy casework and has in operation, a factory adequate in size, with facilities for and devoted to the manufacture of the equipment he or his distributor proposes to supply. This requirement is stated for the Owners protection to eliminate any divided responsibility and to ensure that all completed assemblies shall be in harmony and uniform in design, color, type of hardware, etc., for the completed facility/installation.
*A minimum of five years experience in the design, sale, manufacture, shipping, and installation of the quality and type of pharmacy casework specified herein shall be required.
*Casing, shelves, end panels- Laminate Wilsonart Fusion Maple 7909-60 with PVC edge banding to match laminate. Final finishes to be approved by VA interior design prior to purchase.
| Redding CBOC Project |
| E0618A |
3455 Knighton Road
| Project: Redding CBOC Project |
| Issue Date: October 2020 |
Total Quantity: 7 ☒ Finish Sample Required if Checked ☒ Manufacturer Certified Installation Required if Checked
Item Name: Shelves, Pharmacy, Wall Mtd, Tall, 84"Hx36"Wx18"D Brand Name or Equal: Modular Pharmacy Solutions | Unspecified | null Width: 36 in. Depth: 18 in. Height: 80 - 84 in.
| Salient Characteristics: |
| Main Image: |
Pharmacy metal narcotic storage with mechanical push button lock. Overall dimensions 84" high (+/-4") x 36" wide x 18" deep. 7 interior shelves, adjustable on 1" increments. Cabinet is specific for the storage of Narcotics.
ADDITIONAL REQUIREMENTS ARE AS FOLLOWS:
Materials:
*Sheet Steel: Mild steel, cold rolled furniture grade to requirements of ASTM A1008/A1008M, Grade C or higher, with smooth surfaces to furniture quality.
*16 ga metal *Provide one-piece die-formed cabinet bottom construction with return side flanges turned down.
*Cabinet bottoms shall be turned down at front to form .75” (19mm) floor to accept toe kick and turn down 4.75” (1200mm) at back with 2” (50mm) return to form back lower member of cabinet base and mounting rail for leveler weld nuts. Provide punched .875” (22mm) dia. Corner holes for access to levelers. It shall be possible to access levelers from above cabinet without removing drawer supports.
*Pulls: Provide handles for drawers and hinged doors in [4” (100mm) satin finish aluminum] or [4” (100mm) tubular stainless steel] *Door Hinges: Provide concealed half overlay hinges [zinc coated] screwed into door and fastened to cabinet side with 2 #8 x.375 metal screws.
*Fabricate doors of two metal panels, .875” (22mm) thick when assembled. Reinforce hinge side of door adequately with u shaped hinge channel to prevent sagging or pulling of fasteners. Secure recessed hinges to cabinet with #8 metal screws. Provide each door with two rubber bumpers.
*Doors, drawers, and back panels shall be replaceable in the field without requiring special tools.
*All standard double door cabinets shall be designed without center stiles to maximize access to the cabinet.
*Cabinet construction shall be MIG welded (TIG welded on stainless) to form a strong well-fitted, one-piece unit.
*Locking mechanism is of a push button mechanical design (Simplex) that uses no batteries or power to function. Entry code is changeable.
Powder coated finish.
Final finishes to be approved by VA interior design prior to purchase
General Conditions and Statement of Work Package 002: Pharmacy Modular Casework
| Redding CBOC Project |
| E0618B |
3455 Knighton Road
| Project: Redding CBOC Project |
| Issue Date: October 2020 |
Total Quantity: 16 ☒ Finish Sample Required if Checked ☒ Manufacturer Certified Installation Required if Checked
Item Name: Shelves, Pharmacy, 84"H x 36"W x 24"D Brand Name or Equal: Modular Pharmacy Solutions | Unspecified | null Width: 36 in. Depth: 24 in. Height: 80 - 84 in.
| Salient Characteristics: |
| Main Image: |
Pharmacy storage shelves (double sided) used to store pharmaceutical drug containers and other small containers needed throughout the pharmacy. Overall dimensions (including toe kick) 84" high x 36" wide x 24" deep.
ADDITIONAL REQUIREMENTS ARE AS FOLLOWS:
Materials:
*Core material shall be particle board conforming to CS 236-66 45 pound “B” density, Class 1 of Type 1 *Laminated plastic for general construction shall be 1/32” or 1/16” thick high-pressure type *All top, side and bottom panels and shelf panels shall be laminated with high pressure laminate including cabinet interiors in the same color and finish as selected for exposed surfaces.
*Adhesive for laminate shall be urea-formaldehyde resin free.
*Edge moldings shall be PVC edge band and appear on all edges of the casework that are visibly exposed. Molding shall be the same thickness as shelf when on shelf, counter molding shall be 1-1/4” wide and flush with worksurface.
*Shelving shall be 3/4" thick core with laminate on both sides.
*Casework shall be fabricated using flush construction methods with modern machinery.
*Casework shall be delivered fully constructed and ready for installation. Each unit shall be self-supporting and permit relocation. The sharing of component parts to form a rigid, modular, free-standing assembly shall not be acceptable.
Features:
*Unit shall be securable to the wall via mounting hardware *All shelves shall be 3/4” thick core with high pressure laminate on both sides.
*All shelves noted as being sloping shall also adjust to a flat position. Adjustable vertically on 1" centers and from horizontal to 15, 30, and 45-degree slope down.
*All shelves shall be completely reversible with retainer lips being turned up, down, or to the back as required for use.
*All top, side, and bottom panels and shelf panels shall be laminated with high pressure laminate including cabinet interiors in the same color and finishes as selected for the exposed surfaces. All cabinet backs will have HPL on interior surface.
*Unit shall have a non-adjustable bottom shelf that is the base of the cabinet positioned on top of the toe kick *Unit shall have a 4" toe kick.
*Unit shall have 7 adjustable shelves.
Quality Assurance:
*Manufacturer must have a minimum of 5 years experience in providing manufactured casework for similar types of projects. Manufacturer facility must be certified to premium grade by the AWI Quality Certification Program.
*All pharmacy casework included in this specification shall be made by a pharmacy casework manufacturer who is a specialist in the design and manufacture of pharmacy casework and has in operation, a factory adequate in size, with facilities for and devoted to the manufacture of the equipment he or his distributor proposes to supply. This requirement is stated for the Owners protection to eliminate any divided responsibility and to ensure that all completed assemblies shall be in harmony and uniform in design, color, type of hardware, etc., for the completed facility/installation.
*A minimum of five years experience in the design, sale, manufacture, shipping, and installation of the quality and type of pharmacy casework specified herein shall be required.
*Casing, shelves, end panels- Laminate Wilsonart Fusion Maple 7909-60 with PVC edge banding to match laminate. Final finishes to be approved by VA interior design prior to purchase.
Additional Images of E0618B:
| Redding CBOC Project |
| E0618C |
3455 Knighton Road
| Project: Redding CBOC Project |
| Issue Date: October 2020 |
Total Quantity: 3 ☒ Finish Sample Required if Checked ☒ Manufacturer Certified Installation Required if Checked
Item Name: Shelves, Pharmacy, 36"W x 36"D x 84"H Brand Name or Equal: Modular Pharmacy Solutions | Unspecified | null Width: 36 in. Depth: 36 in. Height: 80 - 84 in.
| Salient Characteristics: |
| Main Image: |
Pharmacy storage shelves (double sided) used to store pharmaceutical drug containers and other small containers needed throughout the pharmacy. Overall dimensions (including toe kick) 84" high (+/-4") x 36" wide x 36" deep. Side 1 is 12" deep shelves. Side 2 is 24" deep shelves.
ADDITIONAL REQUIREMENTS ARE AS FOLLOWS:
Materials:
*Core material shall be particle board conforming to CS 236-66 45 pound “B” density, Class 1 of Type 1 *Laminated plastic for general construction shall be 1/32” or 1/16” thick high-pressure type *All top, side and bottom panels and shelf panels shall be laminated with high pressure laminate including cabinet interiors in the same color and finish as selected for exposed surfaces.
*Adhesive for laminate shall be urea-formaldehyde resin free.
*Edge moldings shall be PVC edge band and appear on all edges of the casework that are visibly exposed. Molding shall be the same thickness as shelf when on shelf, counter molding shall be 1-1/4” wide and flush with worksurface.
*Shelving shall be 3/4" thick core with laminate on both sides.
*Casework shall be fabricated using flush construction methods with modern machinery.
*Casework shall be delivered fully constructed and ready for installation. Each unit shall be self-supporting and permit relocation. The sharing of component parts to form a rigid, modular, free-standing assembly shall not be acceptable.
Features:
*Unit shall be securable to the wall via mounting hardware *All shelves shall be 3/4” thick core with high pressure laminate on both sides.
*All shelves noted as being sloping shall also adjust to a flat position. Adjustable vertically on 1" centers and from horizontal to 15, 30, and 45-degree slope down.
*All shelves shall be completely reversible with retainer lips being turned up, down, or to the back as required for use.
*All top, side, and bottom panels and shelf panels shall be laminated with high pressure laminate including cabinet interiors in the same color and finishes as selected for the exposed surfaces. All cabinet backs will have HPL on interior surface.
*Unit shall have a non-adjustable bottom shelf that is the base of the cabinet positioned on top of the toe kick *Unit shall have a 4" toe kick.
*Unit shall have 7 adjustable shelves.
Quality Assurance:
*Manufacturer must have a minimum of 5 years experience in providing manufactured casework for similar types of projects. Manufacturer facility must be certified to premium grade by the AWI Quality Certification Program.
*All pharmacy casework included in this specification shall be made by a pharmacy casework manufacturer who is a specialist in the design and manufacture of pharmacy casework and has in operation, a factory adequate in size, with facilities for and devoted to the manufacture of the equipment he or his distributor proposes to supply. This requirement is stated for the Owners protection to eliminate any divided responsibility and to ensure that all completed assemblies shall be in harmony and uniform in design, color, type of hardware, etc., for the completed facility/installation.
*A minimum of five years experience in the design, sale, manufacture, shipping, and installation of the quality and type of pharmacy casework specified herein shall be required.
*Casing, shelves, end panels- Laminate Wilsonart Fusion Maple 7909-60 with PVC edge banding to match laminate. Final finishes to be approved by VA interior design prior to purchase.
| Redding CBOC Project |
| U2000 |
3455 Knighton Road
| Project: Redding CBOC Project |
| Issue Date: October 2020 |
Total Quantity: 1 ☒ Finish Sample Required if Checked ☒ Manufacturer Certified Installation Required if Checked
Item Name: Casework, Modular, Pharmacy, Workstation Brand Name or Equal: Modular Pharmacy Solutions | Unspecified | null Width: 215 in. Depth: 28 in. Height: 80 - 84 in.
| Salient Characteristics: |
| Main Image: |
Pharmacy storage and seated height workstation to function as the general administrative task area. Unit is designed to have a 30" high working countertop with cabinetry below and above providing storage and space to hold equipment and supplies. Unit is designed with the following components: Secured suspended upper-case support system with closed storage and open shelving for binder storage, task lighting, solid surface countertop, under counter storage adjustable shelf, CPU holders with knee space for 4 workstations with personal lockable drawer storage, and modular hospital grade duplex outlets. Power entry above ceiling with vendor provided service chase. Overall dimensions (with service chase): 215"wide x 28"deep x 84" (+/-4") high.
ADDITIONAL REQUIREMENTS ARE AS FOLLOWS:
*Core material shall be particle board conforming to CS 236-66 45 pound “B” density, Class 1 of Type 1 *Laminated plastic for general construction shall be 1/32” or 1/16” thick high-pressure type. Adhesive for laminate shall be urea-formaldehyde resin free. Laminated plastic finish shall be finely textured.
*Edge moldings shall be PVC edge band and appear on all edges of the casework that are visibly exposed. Molding shall be the same thickness as shelf when on shelf, counter molding shall be 1-1/4” wide and flush with worksurface.
*Unit shall have a 4" toe kick.
*Casework shall be fabricated using flush construction methods with modern machinery.
*Casework shall be delivered fully constructed and ready for installation. Each unit shall be self-supporting and permit relocation. The sharing of component parts to form a rigid, modular, free-standing assembly shall not be acceptable.
*Steel supports/back panels: shall be capable to support up to 600 pounds. Finish shall be powder coated paint that shall be coordinated with laminate finish. They should include slant brackets at 2” intervals, a retainer clip and shall allow for the adjustment of shelves on steel pins. Back panels shall be removable and able to incorporate electrical duplex boxes.
*The vendor shall provide monitor swing arms to be mounted within the casework at the location of each workstation in location(s) identified by pharmacy administration. Each swing arm will be capable of mounting a CPU and two monitors. Installed outlets shall be in such a location as to not interfere with the prescription processing workspace. The vendor shall also provide PC mounting brackets and mount workstation PCs underneath the counter workspace. Locations shall be identified through an iterative process between the client’s pharmacy representatives and the contractor.
Drawers:
*Drawer module inserts shall be individual modular units that are completely removable and relocatable without being disassembled.
*Drawer suspension shall have full extension travel, full steel ball bearings of carbonized steel and a positive stop and lock-in closed position (self-closing drawer slides).
*Doors and drawer fronts shall be a minimum of 13/16" thick with composed out of the same material as the cabinetry finished with high pressure laminate.
Worksurfaces:
*Countertop shall run the length of the end panels and be composed out of a solid surface material. Core shall be 1-1/8" thick with 1/16" laminate finish.
*Backsplash and returns shall be provided where shown on drawings.
*All exposed edges shall be radiused ¼”.
Shelves:
*All shelves shall be 3/4” thick core with high pressure laminate on both sides.
*All shelves noted as being sloping shall also adjust to a flat position. Adjustable vertically on 1" centers and from horizontal to 15, 30, and 45-degree slope down.
*All shelves shall be completely reversible with retainer lips being turned up, down, or to the back as required for use.
*All top, side, and bottom panels and shelf panels shall be laminated with high pressure laminate including cabinet interiors in the same color and finishes as selected for the exposed surfaces. All cabinet backs will have HPL on interior surface.
Electrical:
*Raceways for electrical and communication services lines to be included where electrical and data coordination is required. Lines shall be 2” wide rib construction with 1/8” Masonite glued to both sides of ribs. Ribs shall be able to be screwed to cabinetry.
*Units are prewired with electrical from the factory and support the data as required.
All modular casework should be field verified prior to purchase/installation. Building contractor to pull wiring. Either construction or activation contractor to have licensed electrician make the connections from building to modular casework.
*Grommet holes to be drilled on site after installation of equipment for proper coordination.
*Task Light: shall be 18", 24" or 36" in length (see drawings for required length and location) and provided with mounting brackets for supporting the fixture from the concealed standards. Lights shall be interchangeable between varying size modules.
Quality Assurance:
*Manufacturer must have a minimum of 5 years experience in providing manufactured casework for similar types of projects. Manufacturer facility must be certified to premium grade by the AWI Quality Certification Program.
*All pharmacy casework included in this specification shall be made by a pharmacy casework manufacturer who is a specialist in the design and manufacture of pharmacy casework and has in operation, a factory adequate in size, with facilities for and devoted to the manufacture of the equipment he or his distributor proposes to supply. This requirement is stated for the Owners protection to eliminate any divided responsibility and to ensure that all completed assemblies shall be in harmony and uniform in design, color, type of hardware, etc., for the completed facility/installation.
*A minimum of five years experience in the design, sale, manufacture, shipping, and installation of the quality and type of pharmacy casework specified herein shall be required.
Finishes:
*Countertop- Solid surface Corian Dove or similar.
*Casing, shelves, end panels- Laminate Wilsonart Fusion Maple 7909-60 with PVC edge banding to match laminate. Final finishes to be approved by VA interior design prior to purchase.
Additional Images of U2000:
| Redding CBOC Project |
| U2001 |
3455 Knighton Road
| Project: Redding CBOC Project |
| Issue Date: October 2020 |
☒ Finish Sample Required if Checked ☒ Manufacturer Certified Installation Required if Checked
Item Name: Casework, Modular, Pharmacy, Transaction Window Station Brand Name or Equal: Modular Pharmacy Solutions | Unspecified | null Width: 143 in. Depth: 24 in. Height: 30 in.
| Salient Characteristics: |
| Main Image: |
Pharmacy storage and workstation to function as the transaction window station. An adjustable height platform will be provided for the staff at the transaction/dispensing window(s) and consult counter as part of another package (reference JSN M1803B). Unit is designed to have a 30" high working countertop with cabinetry below providing limited storage and space to hold equipment and supplies. Unit is designed with the following components: solid surface countertop, under counter drawer storage, CPU holder, knee space for 2 48" wide workstations to process orders, and modular hospital grade duplex outlets. Power entry at wall . Overall dimensions: 143"wide x 24"deep x 30"high. This unit works in conjunction with U2002 to create a continuous working area.
ADDITIONAL REQUIREMENTS ARE AS FOLLOWS:
*Core material shall be particle board conforming to CS 236-66 45 pound “B” density, Class 1 of Type 1 *Laminated plastic for general construction shall be 1/32” or 1/16” thick high-pressure type. Adhesive for laminate shall be urea-formaldehyde resin free. Laminated plastic finish shall be finely textured.
*Edge moldings shall be PVC edge band and appear on all edges of the casework that are visibly exposed. Molding shall be the same thickness as shelf when on shelf, counter molding shall be 1-1/4” wide and flush with worksurface.
*Unit shall have a 4" toe kick.
*Casework shall be fabricated using flush construction methods with modern machinery.
*Casework shall be delivered fully constructed and ready for installation. Each unit shall be self-supporting and permit relocation. The sharing of component parts to form a rigid, modular, free-standing assembly shall not be acceptable.
*Steel supports/back panels: shall be capable to support up to 600 pounds. Finish shall be powder coated paint that shall be coordinated with laminate finish. They should include slant brackets at 2” intervals, a retainer clip and shall allow for the adjustment of shelves on steel pins. Back panels shall be removable and able to incorporate electrical duplex boxes.
*The vendor shall provide monitor swing arms to be mounted within the casework at the location of each workstation in location(s) identified by pharmacy administration. Each swing arm will be capable of mounting a CPU and two monitors. Installed outlets shall be in such a location as to not interfere with the prescription processing workspace. The vendor shall also provide PC mounting brackets and mount workstation PCs underneath the counter workspace. Locations shall be identified through an iterative process between the client’s pharmacy representatives and the contractor.
Drawers:
*Drawer module inserts shall be individual modular units that are completely removable and relocatable without being disassembled.
*Drawer suspension shall have full extension travel, full steel ball bearings of carbonized steel and a positive stop and lock-in closed position (self-closing drawer slides).
*Doors and drawer fronts shall be a minimum of 13/16" thick with composed out of the same material as the cabinetry finished with high pressure laminate.
Worksurfaces:
*Countertop shall run the length of the end panels and be composed out of a solid surface material. Core shall be 1-1/8" thick with 1/16" laminate finish.
*Backsplash and returns shall be provided where shown on drawings.
*All exposed edges shall be radiused ¼”.
Shelves:
*All shelves shall be 3/4” thick core with high pressure laminate on both sides.
*All shelves noted as being sloping shall also adjust to a flat position. Adjustable vertically on 1" centers and from horizontal to 15, 30, and 45-degree slope down.
*All shelves shall be completely reversible with retainer lips being turned up, down, or to the back as required for use.
*All top, side, and bottom panels and shelf panels shall be laminated with high pressure laminate including cabinet interiors in the same color and finishes as selected for the exposed surfaces. All cabinet backs will have HPL on interior surface.
Hardware:
*Hinges shall be concealed, self-closing and 3 way adjustable. They shall be constructed out of nickel-plated steel with 110 degree opening.
*Locks shall be multi-tumbler chrome plated brass with brass slide bolt.
Electrical:
*Raceways for electrical and communication services lines to be included where electrical and data coordination is required. Lines shall be 2” wide rib construction with 1/8” Masonite glued to both sides of ribs. Ribs shall be able to be screwed to cabinetry.
*Units are prewired with electrical from the factory and support the data as required.
All modular casework should be field verified prior to purchase/installation. Building contractor to pull wiring. Either construction or activation contractor to have licensed electrician make the connections from building to modular casework.
*Grommet holes to be drilled on site after installation of equipment for proper coordination.
*Task Light: shall be 18", 24" or 36" in length (see drawings for required length and location) and provided with mounting brackets for supporting the fixture from the concealed standards. Lights shall be interchangeable between varying size modules.
Quality Assurance:
*Manufacturer must have a minimum of 5 years experience in providing manufactured casework for similar types of projects. Manufacturer facility must be certified to premium grade by the AWI Quality Certification Program.
*All pharmacy casework included in this specification shall be made by a pharmacy casework manufacturer who is a specialist in the design and manufacture of pharmacy casework and has in operation, a factory adequate in size, with facilities for and devoted to the manufacture of the equipment he or his distributor proposes to supply. This requirement is stated for the Owners protection to eliminate any divided responsibility and to ensure that all completed assemblies shall be in harmony and uniform in design, color, type of hardware, etc., for the completed facility/installation.
*A minimum of five years experience in the design, sale, manufacture, shipping, and installation of the quality and type of pharmacy casework specified herein shall be required.
Finishes:
*Casing, shelves, end panels- Laminate Wilsonart Fusion Maple 7909-60 with PVC edge banding to match laminate. Final finishes to be approved by VA interior design prior to purchase.
Additional Images of U2001:
Section at Window
| Redding CBOC Project |
| U2002 |
3455 Knighton Road
| Project: Redding CBOC Project |
| Issue Date: October 2020 |
☒ Finish Sample Required if Checked ☒ Manufacturer Certified Installation Required if Checked
Item Name: Casework, Modular, Pharmacy, Order Entry Station Brand Name or Equal: Modular Pharmacy Solutions | Unspecified | null Width: 184 in. Depth: 28 in. Height: 80 - 84 in.
| Salient Characteristics: |
| Main Image: |
Pharmacy storage and seated height workstation to function as the order entry and processing station. Unit is designed to have a 30" high working countertop with cabinetry below and above providing storage and space to hold equipment and supplies. Unit is designed with the following components: Secured suspended upper-case support system with closed storage and open shelving for binder storage, task lighting, solid surface countertop, under counter storage with a pullout printer shelf, CPU holder, knee space for 2 workstations to process orders, and modular hospital grade duplex outlets. Power entry above ceiling with vendor provided service chase. Overall dimensions (with service chase): 184"wide x 28"deep x 84"high (+/-4"). This unit works in conjunction with U2001 to create a continuous working area.
ADDITIONAL REQUIREMENTS ARE AS FOLLOWS:
*Core material shall be particle board conforming to CS 236-66 45 pound “B” density, Class 1 of Type 1 *Laminated plastic for general construction shall be 1/32” or 1/16” thick high-pressure type. Adhesive for laminate shall be urea-formaldehyde resin free. Laminated plastic finish shall be finely textured.
*Edge moldings shall be PVC edge band and appear on all edges of the casework that are visibly exposed. Molding shall be the same thickness as shelf when on shelf, counter molding shall be 1-1/4” wide and flush with worksurface.
*Unit shall have a 4" toe kick.
*Casework shall be fabricated using flush construction methods with modern machinery.
*Casework shall be delivered fully constructed and ready for installation. Each unit shall be self-supporting and permit relocation. The sharing of component parts to form a rigid, modular, free-standing assembly shall not be acceptable.
*Steel supports/back panels: shall be capable to support up to 600 pounds. Finish shall be powder coated paint that shall be coordinated with laminate finish. They should include slant brackets at 2” intervals, a retainer clip and shall allow for the adjustment of shelves on steel pins. Back panels shall be removable and able to incorporate electrical duplex boxes.
*The vendor shall provide monitor swing arms to be mounted within the casework at the location of each workstation in location(s) identified by pharmacy administration. Each swing arm will be capable of mounting a CPU and two monitors. Installed outlets shall be in such a location as to not interfere with the prescription processing workspace. The vendor shall also provide PC mounting brackets and mount workstation PCs underneath the counter workspace. Locations shall be identified through an iterative process between the client’s pharmacy representatives and the contractor.
Drawers:
*Drawer module inserts shall be individual modular units that are completely removable and relocatable without being disassembled.
*Drawer suspension shall have full extension travel, full steel ball bearings of carbonized steel and a positive stop and lock-in closed position (self-closing drawer slides).
*Doors and drawer fronts shall be a minimum of 13/16" thick with composed out of the same material as the cabinetry finished with high pressure laminate.
Worksurfaces:
*Countertop shall run the length of the end panels and be composed out of a solid surface material. Core shall be 1-1/8" thick with 1/16" laminate finish.
*Backsplash and returns shall be provided where shown on drawings.
*All exposed edges shall be radiused ¼”.
Shelves:
*All shelves shall be 3/4” thick core with high pressure laminate on both sides.
*All shelves noted as being sloping shall also adjust to a flat position. Adjustable vertically on 1" centers and from horizontal to 15, 30, and 45-degree slope down.
*All shelves shall be completely reversible with retainer lips being turned up, down, or to the back as required for use.
*All top, side, and bottom panels and shelf panels shall be laminated with high pressure laminate including cabinet interiors in the same color and finishes as selected for the exposed surfaces. All cabinet backs will have HPL on interior surface.
Electrical:
*Raceways for electrical and communication services lines to be included where electrical and data coordination is required. Lines shall be 2” wide rib construction with 1/8” Masonite glued to both sides of ribs. Ribs shall be able to be screwed to cabinetry.
*Units are prewired…