This document is a product specification for a brand name 40-conductor cable required for installation at SNOTEL sites within the Montana Data Collection Office (MTDCO) of the U.S. Department of Agriculture. The only acceptable cable is the Alpha Wire 5170/40C XtraGuard 1 model, which meets the specific requirements of 40 conductors, 18 AWG gauge, and functionality at temperatures below 20 degrees Celsius. The solicitation number is 12FPC324Q0099, and the award will be made on a lowest price, technically acceptable basis. The solicitation is issued by the USDA Under Secretary for Farm Production and Conservation.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| S01 Combined Synopsis 12FPC324Q0099 30Jul24.pdf | ||
| S01 Combined Synopsis 12FPC324Q0099 30Jul24.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Product Description (Brand Name Only)
This is a brand name product description.
Due to the specific use requirements at SNOTEL Supersites within the Montana Data Collection Office (MTDCO), 40 component multi conductor wires are required for installation at SNOTEL sites within the MTDCO. After market research, and field testing, the listed cable is the only cable on the market which meets the need for a multi‐strand conductor wire with enough stands (40), sufficient cable gauge (18AWG), and is functional in an acceptable temperature range (below ‐20 degrees Celsius).
As such, the only acceptable cable that is acceptable for this procurement is the following:
Manufacturer: Alpha Wire Manufacturer Part Number: 5170/40C 40C Part Name: Xtra‐Guard 1 5170/40C
Specific Part Information
1. Component 40 X 1 Conductor Cable
a) Conductor 18 (16/30) AWG Tinned Copper
b) Insulation 0.016" Wall, Nom. PVC 0.079
2) Cable Assembly 40 Components Cabled
a) Twists: 1.4 Twists/foot (min)
b) Orientation: Components to be arranged from INSIDE LAYER to OUTSIDE LAYER
c) Core Wrap Nonwoven Polyester Tape, 20% Overlap, Min.
3) Shield: A/P/A Tape, 20% Overlap, Min.
a) Drain Wire 18 (16/30) AWG Tinned Copper
b) Braid Tinned Copper,70% Coverage, Nom.
4) Jacket 0.053" Wall, Nom.,PVC 0.722 (0.750 Max.)
a) Color(s) Gray
b) Ripcord 1 End 810 Denier Nylon
c) Print ALPHA WIRE‐* P/N 5170/40C 40C 18 AWG
XTRAGUARD(R) 1 SHIELDED (UL) TYPE CM 105C SUN RES
OR AWM 2464 80C 300V OR AWM 2517 105C 300V
VW‐1 OR C(UL) TYPE CMG 105C FT4 CE ROHS
OIL RESISTANT (SEQ FOOTAGE)
Conductor MUST have the specific wire colors listed in the table below:
Cond Color Cond Color Cond Color
1 BLACK 15 RED/BLACK 29 WHITE/BLACK/BROWN
2 RED 16 WHITE/BLACK 30 WHITE/BLACK/ORANGE
3 WHITE 17 WHITE/RED 31 WHITE/BLACK/SLATE
4 GREEN 18 WHITE/GREEN 32 WHITE/BLACK/VIOLET
5 ORANGE 19 WHITE/YELLOW 33 WHITE/BLACK/BLACK
6 BLUE 20 WHITE/BLUE 34 WHITE/RED/BLACK
7 BROWN 21 WHITE/BROWN 35 WHITE/RED/RED
8 YELLOW 22 WHITE/ORANGE 36 WHITE/RED/GREEN
9 VIOLET 23 WHITE/SLATE 37 WHITE/RED/BLUE
10 SLATE 24 WHITE/VIOLET 38 WHITE/RED/BROWN
11 PINK 25 WHITE/BLACK/RED 39 WHITE/RED/VIOLET
12 TAN 26 WHITE/BLACK/GREEN 40 WHITE/GREEN/BLACK
13 RED/GREEN 27 WHITE/BLACK/YELLOW
14 RED/YELLOW 28 WHITE/BLACK/BLUE