P01 Specifications-Sizing-Info for Sterilizer.docx

DOCX document 18 KB Posted

Attached to
6530--Steam Sterilizer and Lab Glassware Washer
Solicitation number
36C24E26Q0075
Issued by

About this file

This document contains specifications and salient characteristics for a steam sterilizer required for a BioSafety Level II research facility operated by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 4. The sterilizer must be research-grade life science equipment with an internal chamber measuring no less than 20" x 20" x 38", external dimensions not exceeding 76"H x 43"W x 49"D, and a single door chamber design. The equipment must feature multiple programmable cycles including gravity, liquid, pre-vacuum, and isothermal functions, with temperature capabilities up to 285°F, a colored touchscreen display, and printing capabilities.

The sterilizer must arrive fully assembled and operational with no required building modifications or utility changes; it must function as plug-and-play equipment with efficient exhaust suitable for the BioSafety Level II VMU facility. The contractor must provide a minimum one-year warranty and commit to servicing any equipment malfunctions within 48 hours of the initial service call. The equipment cost must not exceed the awarded contract amount. This pre-solicitation (Solicitation Number 36C24E26Q0075) is for animal laboratory glassware washer and sterilizer units and represents an upcoming federal contract opportunity.

View the file

Other files

File Type Posted
P01 Info - Steris Reliance 300XLS Laboratory Washer.docx DOCX document
Sources Sought Package Lab Sterilizer and Washer.docx DOCX document
P01 Info AMSCO Sterilizer TECHNICAL Sheet.docx DOCX document
36C24E26Q0075.docx DOCX document
P01 SOW Sterilizer and Glassware Wash SOW.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Specifications and Salient Characteristics Sterilizer Physical & Function Characteristics:

Cost must not exceed LAM award. Must be research/life science equipment. Must be suitable for BioSafety Level II VMU Facility. Internal chamber dimension should be no less than 20” x 20” x 38”. External dimensions should exceed no greater than 76”H x 43”W x 49”D. Must be a one door chamber. Must have multiple programable cycles. Must have gravity, liquid, pre-vacuum and isothermal cycles. Must have various temperatures leading up to 285F. Must have colored touchscreen display. Printing capabilities. Current exhaust must be efficient for equipment.

Assembling, Modifications & Scope of Work Requirements:

Equipment must come already assembled, must require no building modifications or utility changes. Equipment must be plug and play.

Warranty:

Must include at least a one year warranty. Contractor must service equipment in the event of a malfunction no later than 48 hours after initial call.