P01 Specifications-Sizing-Info for Sterilizer.docx

DOCX document 18 KB Posted

Attached to
6530--Steam Sterilizer and Lab Glassware Washer
Solicitation number
36C24E26Q0073
Issued by

About this file

This document is a specifications and requirements sheet for a steam sterilizer to be procured by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 4 for use in a BioSafety Level II VMU Facility. The sterilizer must be research/life science equipment that arrives fully assembled and ready for plug-and-play installation without requiring any building modifications or utility changes. The internal chamber must measure no less than 20" x 20" x 38", with external dimensions not exceeding 76"H x 43"W x 49"D, and must feature a single-door chamber design.

The equipment must include multiple programmable sterilization cycles, specifically gravity, liquid, pre-vacuum, and isothermal cycles, with capabilities to reach temperatures up to 285°F. Additional required features include various temperature settings, a colored touchscreen display, printing capabilities, and efficient exhaust capabilities compatible with current equipment. The sterilizer cost must not exceed the amount of the LAM award and must be accompanied by a minimum one-year warranty with guaranteed contractor service response within 48 hours of any malfunction call. This is a pre-solicitation opportunity identified as solicitation number 36C24E26Q0073 for an Animal Lab Washer and Sterilizer.

View the file

Other files

File Type Posted
P01 SOW Sterilizer and Glassware Wash SOW.docx DOCX document
P01 Info - Steris Reliance 300XLS Laboratory Washer.docx DOCX document
Sources Sought Package Lab Sterilizer and Washer.docx DOCX document
P01 Info AMSCO Sterilizer TECHNICAL Sheet.docx DOCX document
36C24E26Q0073.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Specifications and Salient Characteristics Sterilizer Physical & Function Characteristics:

Cost must not exceed LAM award. Must be research/life science equipment. Must be suitable for BioSafety Level II VMU Facility. Internal chamber dimension should be no less than 20” x 20” x 38”. External dimensions should exceed no greater than 76”H x 43”W x 49”D. Must be a one door chamber. Must have multiple programable cycles. Must have gravity, liquid, pre-vacuum and isothermal cycles. Must have various temperatures leading up to 285F. Must have colored touchscreen display. Printing capabilities. Current exhaust must be efficient for equipment.

Assembling, Modifications & Scope of Work Requirements:

Equipment must come already assembled, must require no building modifications or utility changes. Equipment must be plug and play.

Warranty:

Must include at least a one year warranty. Contractor must service equipment in the event of a malfunction no later than 48 hours after initial call.