P01_SOW_Locks.docx

DOCX document 39 KB Posted

Attached to
5340--36C25924Q0151 LIGATURE RESISTANT STOREROOM LOCK (RIGHT HAND)
Solicitation number
36C25924Q0151
Issued by

About this file

This statement of work outlines requirements for ligature resistant locks and mortises for the Rocky Mountain Regional VA Medical Center in Aurora, Colorado. The contractor shall deliver various ligature resistant lock and mortise parts by Accurate Locks and Hardware or equivalent, totaling 2 of each of 6 part numbers, within 30 days of award. Delivery and installation shall be coordinated with the on-site point of contact at the medical center. The contractor must provide operation and maintenance manuals and manufacturer warranties that cover all travel and shipping costs for warranty repairs.

The related federal contract opportunity is a solicitation for 5340--36C25924Q0151 seeking ligature resistant storeroom locks with a right hand orientation. Bids are due on January 12, 2024 at 4:00PM for this requirement supporting the Rocky Mountain Regional VA Medical Center.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Statement of Work Ligature Resistant Locks and Mortise Eastern Colorado Health Care System Aurora, CO 14 Novemeber 2023

1. PURPOSE

1.1. The purpose of this requirement is to deliver Ligature resistant locks and mortises at VA Eastern Colorado Health Care System, located at 1700 N. Wheeling Street, Aurora, CO 80045.

2. SCOPE

2.1. The Contractor shall deliver all items listed in section 2.5.

2.2. All items must meet all salient characteristics defined in section 2.5.

2.3. Installation must meet manufacturer specifications. (delete if not applicable)

2.5ITEM SPECIFICATIONS AND SALIENT CHARACTERISTICS
2.5.1.Detailed Item Description Example: Accurate Locks and Mortise P/N’s ALHCH9159SEC.234.L.PC.US26D.RH.134, ALHCH9159SEC.234.L.PC.US26D.LH.134, ALH9143BL.234.US26D.RH.134, ALH9143BL.234.US26D.LH.134, ALH9159SEC.234.US26D.RH.134 and ALH9159SEC.234.US26D.LH.134 or equvilant
Quantity: 2 ea of ALHCH9159SEC.234.L.PC.US26D.RH.134, 6 ea of ALHCH9159SEC.234.L.PC.US26D.LH.134, 10 ea of ALH9143BL.234.US26D.RH.134, 8 ea of ALH9143BL.234.US26D.LH.134, 6 ea ALH9159SEC.234.US26D.RH.134, and 3 ea of ALH9159SEC.234.US26D.LH.134

Basis of Design (make/model/Mfr Part No): Accurate Lock and Hardware P/N’s or equvilant Technical Specifications/Salient Characteristics:

· The highest level of ligature resistance featuring Paperclip Protection.

· UL Listed 3 Hour (R13846, R27504).

· Meets BHMA 156.34 Ligature Resistant Trim Standard.

· Passed ASTM F 1577 impact testing.

· Compatible with any standard mortise cylinder (must be ordered with appropriate cam).

· US26D/US32D finish standard, anti-microbial plating available.

· Supplied with Torx® Security Screws

· Available in large backsets for specialty applications (e.g. acoustical doors, specialty stops, etc.)

· Dimensions: 12-1/4" high by 4 -3/32" wide with a projection of 2-7/32".

· Latch Bolt: .687 thick

· Ligature Resistant Stroreroom Lock and Mortise 9159 Series P/N’s ALHCH9159SEC.234.L.PC.US26D.RH.134 Ligature resistant storeroom lock , ALHCH9159SEC.234.L.PC.US26D.LH.134 Ligature resistant storeroom lock, ALH9159SEC.234.US26D.RH.134 Ligature resistant mortise only RH storeroom and ALH9159SEC.234.US26D.LH.134 Liagture resistant mortise only LH storeroom.

· Latch by handle inside and key outside.

· Outside handle always rigid.

· Auxiliary latch deadlocks latch bolt.

· Ligature resistant mortise 9143 series Institutional Privacy P/N’s ALH9143BL.234.US26D.RH.134. Ligature resistant mortise only RH Institutional privacy and ALH9143BL.234.US26D.LH.134 Ligature resistant mortise only LH institutional privacy.

· Latch boly by handle either side unless outside handle is locked by thumb turn

· Thumb turn locks or unlocks outside handle

· Key lock or unlocks outside handle

2.6 DELIVERY AND INSTALLATION

2.6.1. DELIVERY

2.6.1.1. Delivery Timeframe: within 30 days of award unless specified differently within scope of contract.

2.6.1.2. Delivery Location: Contractor shall deliver all equipment to the Eastern Colorado Health Care System, 1700 N. Wheeling Street, Aurora, CO 80045

2.6.1.3. Delivery Markings: Contractor shall deliver items in manufacturer's original sealed containers with manufactures’s name marked thereon. Deliveries shall be marked with the PO and contract number.

2.6.1.4. Delivery and Installation will be coordinated through the On-Site Point of Contact (POC). POCs for delivery and install are:

Services POCs; Email; Phone #

2.7. OPERATION AND MAINTENANCE MANUALS

2.7.1. Binders - Quantity (2) each for items identified in section 2.5

2.7.2. Digital Copies - Quantity (1) each for items identified in section 2.5.

2.7.3. Deliver compilation of all manufacturer recommended maintenance schedule and operation materials packaged in binder(s) to On-Site Point of Contact upon completion of installation.

3.1. SECURITY REQUIREMENTS

3.1.1. Security background checks are not required.

3.2. WARRANTY

3.2.1. The contractor shall provide all manufacturer(s) warranties on all parts and labor at time of delivery.

3.2.2. The warranties shall include all travel and shipping costs associated with any warranty repair.

File details come from the government source that posted it. Updated .