Salient Characteristics

Page | 1 640-23-2-5046-0027

Framery Q Floorless Meeting or Equal

Salient Characteristics

GENERAL REQUIREMENTS

Exterior material shell be:

o Painted sheet metal or brushed stainless steel.

o Glass: Sound control laminated glass.

o Frame: Formica laminate on birch plywood with varnish trim.

Interior material shell be:

o Solid walls and roof: A sandwich element of sheet metal, birch plywood, recycled acoustic foam and acoustic felt.

o Floor: Low threshold floor, wheelchair accessible. An anti-static and stain resistant low loop pile carpet for interior floor.

o All electrical components shall be tested according to ISO/IEC guide 17067 and are certified against: IEC 62368-1 and UL 962 (For North American markets). All electric components can be changed if there is a malfunction.

o Pods shall be anchored to the floor to reduce the risk of the pod falling in the event of an earthquake., Manufacturer to provide seismic test reports upon request.

o Product shall provide adequate ventilation to ensure the temperature inside the pod to maintain CO₂ levels inside the pods below the maximum levels recommended in EN 15251 and ASHRAE 62.1. (Provided the CO₂ concentration in the space surrounding the pod is at an acceptable level.)

o The pod and its door (when opened) must not block any path of egress.

o Pods Shall have soft radius edges.

o Meet accessibility requirement of Americans with Disabilities Act (ADA).

o All materials used to construct pods shall be tested and classified according to the

American ASTM E84 / UL 723 standards.

o Pods shall be mainly constructed of birch plywood.

o Majority of our materials used shell be recycled or recyclable.

o The acoustic foam and the interior felt used for this product shall be up to 60–70 % recycled. Part of all steel, aluminum and glass shall be recycled in their manufacturing processes.

o Pods shall be highly energy-efficient when the products are in use, default power consumption of pods shell be minimum of 20 W while active.

DIMENSIONS AND FEATURES

o Overall Exterior Dimension: 87”- 87.4”H × 82” - 86.6”W × 46.8” - 47.2”D o Overall Interior Dimension: 74” - 78”H × 74” - 78”H × 40” - 43.2”D o Doorway Minimum 33.6 in wide with clear opening width of 36”, Left-handed o Ventilation space Minimum 5 cm / 1.9 in (sides) and 15 cm / 5.9 in (above) o Product weight: 700 kg / 1543 lb

Technical Specification

Accessible features o Low floor with beveled threshold at the doorway o Height of door handle (inside and out) o Circular turning space inside the pod (without optional table) o Headroom inside the pod

Page | 2 640-23-2-5046-0027 o Wide doorway (32.3 in / 82 cm) Lighting o Led light: 4500 K and 300 lux

Power consumption o 20 W while in use (Standard configuration) o LED lights: 11 W o Fans in total: 8,6 W o 2,1 W in standby mode Input: 100-240 VAC, 8.0 A, 50-60 Hz

Seismic Safety o Wedge anchors bolted to the floor o Using existing holes in the floor modules of the pod. 8 bolts per pod o Load: 7.36 kN.

o Load per ft²: 23.6 lbs.

o Load per m²: 115.4 kg o Seismically tested

Fire Safety product structure and material o Class A wall, ceiling, and floor panel structures o Class A Laminated glass o Class A Painted sheet metal material and Class A1 (non-combustible) o Class C, B-s2, d0 Felt o Class C, Bfl-s1 Carpet o Class C, Class D-s2 d0 Plywood o Class A, B-s1, d0 Acoustic panels o If the pods are placed in relation to external sprinklers and visible and audible alarms as recommended in section 4.3, there is no need for separate end devices inside the pod.

No Sprinkler needed Requirement:

o Products shall not exceed the 9 – 12 square meter area covered by a single sprinkler.

o The products Shall not contain any easily combustible materials and therefore do not increase the fire load of the surrounding space by hindering the operation of the sprinklers in it.

o Products shall be considered movable furniture instead of building structures that sprinkler requirements are typically set for.

o Documents and statements shall be available upon request.

Power and Electrical components o Input: 100-240 VAC, 8.0 A, 50-60 Hz o Output: VAC (power socket): 100-240 VAC, 6.6A, 50-60 Hz o Output USB (TUF) charging: Maximum combined output of 5A at 5 VDC (25W) o Power consumption: Standard 20 W - 23 W total o General: Power cord length 2-10 m o Power feed option either from top or bottom of pod, w/ 3 power sockets

Ventilation o Air flow rate: 140 CFM, 66 l/s o Air change rate (Air changes per hour): approx. 54 o Air flows in through the ceiling of the pod and out through the sides of the floor modules.

o By default, after minimum of 8 minutes of no use, the flow rate slows down to 25% of the maximum flowrate to keep the air inside the pod fresh.

Page | 3 640-23-2-5046-0027

WARRANTY REQUIREMENTS

Manufacturer must offer warranty for wear parts including gas lifts, leveling glides, LED lighting, electric parts, hinges, and locks. Regular maintenance shall extend the lifespan of a single pod unit substantially. Maintenance includes regular service calls for the unit (tightening screws, adjusting hinges, etc.) and the replacement of wear parts.

ENVIRONMENTAL FEATURES

Qualifies for LEED Contribution o Recycled content o Materials reuse o Regional materials o Low-emitting materials o Interior life cycle impact reduction o Environmentally Preferable finishes and furnishings o Social equity in the supply chain o Certified and report by the Global Reporting Initiative (GRI) principles o Supports UN Global Compact o Certified according to ISO 14001 and ISO 45001 o Life Cycle Assessment according to ISO 14040 and 14044 and released industry first

Environmental Product Declarations (EPD) according to ISO 14025 o Health Product Declaration compliant o GREENGUARD certified o Wood is FSC / PEFC certified o Fabrics are EU Ecolabel marked

Material Chemistry o Must offer PVC-free power components to avoid potential long-term human and environmental impacts that have been associated with the manufacture and future disposal of PVC.

o Plywood used in products has a sustainable forestry FSC or PEFC certification.

o Product constructed mostly of plywood, steel, glass, and acoustic materials.

o Sound dampening panels are made up to 60% and the felt panels are made up to 80% of recycled PET plastic (e.g. Plastic bottles).

o Significant part of all steel, aluminum and glass is recycled during their manufacturing processes.

Certifications o SCS Indoor Advantage Gold o BIFMA level 2 o Furniture must be certified to meet the emissions requirements of the California DPH

Standard Practice for the Testing of Volatile Organic Emissions from Various Sources- 2004 (CA Section 01350) and ANSI/BIFMA X7.1 Standard for Formaldehyde and TVOC Emissions of Low-emitting Office Furniture Systems and Seating using either the open plan or private office exposure scenarios defined in ANSI/BIFMA M7.1 Standard Test Method for Determining VOC Emissions from Office Furniture Systems, Components, and Seating. Testing must be conducted in accordance with ANSI/BIFMA M7.1.

Certification must be provided by an organization independent of the manufacturer as

Page | 4 640-23-2-5046-0027 well as from the testing laboratory, in accordance with the requirements of ISO/IEC Guide 65 General requirements for bodies operating product certification systems.

o The above requirement is covered by SCS Indoor Advantage™ Gold Certification for indoor air quality.

o Product shall be at least Level® 2 Certified with the BIFMA e3 Furniture Sustainability Standards to meet or exceed the most current environmental standards in the furniture industry.

SURFACE MATERIALS

White o Exterior standard: Glossy RAL 9016 o Frame Standard: Formica K1009 Matt