This document specifies the salient characteristics and technical requirements for a Zeiss Humphrey Field Analyzer 3 perimeter device required by the Department of Veterans Affairs. The equipment must perform automated visual field testing with liquid trial lens technology, automated eye alignment, and a fixation monitoring system (RelEYE). Essential capabilities include guided progression analysis (GPA), comprehensive fixation control features (head tracking, gaze tracking, video eye monitor, Heijl-Krakau blind spot monitor, and vertex monitoring), and visual field index functionality. The device must operate on Windows 10 with a smart touch interface, include 500 GB internal storage, and meet standard U.S. electrical requirements (100-120V, 50/60 Hz, 4.0A).
The equipment specifications require FORUM Connectivity and FORUM Glaucoma Workplace integration, DICOM connectivity, and an Integrated Diagnostic Imaging Platform for Glaucoma that connects with Cirrus HD-OCT technology. The device must include SITA database functionality and a table, with dimensions of 18"D x 20"W x 23"H. One unit is being procured through RFQ solicitation 36C24W26Q0073 (NAICS 339115) under the Buy American Act requirement for U.S.-manufactured products. The procurement is unrestricted open-market with no specific incumbent identified.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| S01_RFQ Description_36C24W26Q0073.pdf | ||
| S01_RFQ_36C24W26Q0073_1.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SALIENT CHARACTERISTICS
Brand Name or Equivalent
M5555 – Perimeter, Automated – Zeiss Humphrey Field Analyzer 3
a) Must be capable in performing perimetry- visual field testing
b) Liquid trial lens technology is included
c) Must have automated eye alignment
d) Fixation monitoring system (RelEYE) is a must
e) Must have the capability to do guided progression analysis (GPA)
f) Shall have fixation control: head tracking, gaze tracking, video eye monitor, Heijl- Krakau blind spot monitor, and vertex monitoring
g) Must have visual field index
h) Must include power supply and adapters for USA conventional 120V outlet
i) Electrical Requirement must have: 100-120v- 50/60 Hz, 4.0A
j) Must have smart touch interface
k) Must have operating system: windows 10
l) Shall have internal storage: 500 Gb
m) Must include FORUM Connectivity
n) Must include FORUM glaucoma Workplace
o) Must have DICOM Connectivity
p) Must include Integrated Diagnostic Imaging Platform for Glaucoma, (Glaucoma Workplace) connects Cirrus HD-OCT
q) Must have SITA database
r) Must include table
s) Dimension: 18”D x 20”W x 23”H
t) Quantity: 1