Ozark Metal Siding Plans.pdf
PDF 486 KB Posted
- Solicitation number
- 300000284026877
- Issued by
- Missouri
About this file
Summary
This is a set of architectural plans and specifications for the Missouri Department of Transportation (MoDOT) Division of General Services Facilities Management regarding metal roof and siding replacement at the Ozark Maintenance facility located at 1810 Selmore Road, Ozark, Missouri 64721 in Christian County. The project requires contractors to remove all existing exterior metal siding and install new 26-gauge prefinished metal siding, gutters, and downspouts around the entire structure; replace the metal roofing system with 26-gauge mechanically seamed Galvalume standing seam panels with R30 insulation; and perform associated work including replacement of three man-doors, five LED light fixtures, roof boots, and louvers. The contractor must also handle rerouting of HVAC vents, removal of roof penetrations, electrical and mechanical system modifications, and landscape restoration. Site visit attendance is mandatory for bid acceptance, and bids must be submitted electronically through MissouriBUYS or via mail/UPS/FEDEX with required advance notice to the buyer of record at logan.wilbers@modot.mo.gov at least five business days prior to the bid closing date.
The plans specify that all work must comply with current International Building Code standards and that the contractor is responsible for verifying all conditions and dimensions, coordinating all trades, disposing of debris off-site, contacting and disconnecting/reconnecting all utilities, and maintaining a safe work environment with appropriate personal protective equipment. The color scheme must match existing specifications with tan siding and dark brown trim, and specific hardware and material specifications are detailed for doors, fixtures, and equipment. The contractor must supply stamped engineered repairs for any structural steel work and provide a separate bid line item for fall protection systems meeting OSHA requirements. All restoration work, including regrading and reseeding of damaged landscaping areas, must be completed to MoDOT standards prior to final project acceptance.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| MODOT 0000000420SL_SUPPLIER.pdf | ||
| Ozark Metal Siding Photos.docx | DOCX document | |
| Ozark Metal Siding Spec.docx | DOCX document | |
| AWO 33.pdf | ||
| section 01300 and 01700.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
OZARK MAINTENANCE METAL ROOF AND SIDING - SOUTHWEST DISTRICT
1810 SELMORE ROAD, OZARK, MO 64721
CHRISTIAN COUNTY
MISSOURI DEPARTMENT OF TRANSPORTATION
INDEX OF DRAWINGS CODE REQUIREMENTS
PROJECT NOTES
CODE ANALYSIS
M
IS
SO
U
R I D
EP
A
R
TM
EN
T
O F
TR
A
N
SP
O R
TA
TI
O N
D
IV
IS
IO
N O
F G
EN
ER
A L
SE
R
V
IC
ES
FA
C
IL
IT
IE
S M
A N
A G
EM
EN
T C
O V
ER
S
H
EE
T O
ZA
R
K M
A
IN
TE
N
A N
C E
M
ET
A L
R O
O F
A N
D S
ID
IN
G
SO
U
TH
W
ES
T
D
IS
TR
IC
T
S
EL
M
O R
E R
O A
D , O
ZA
R
K , M
O
C H
R
IS
TI
A
N C
O U
N
TY
AutoCAD SHX Text
BUILDING CODE - CURRENT IBC
AutoCAD SHX Text
USE GROUP CLASSIFICATION GROUP B, BUSINESS
AutoCAD SHX Text
1. CONTRACTOR SHALL VERIFY ALL CONDITIONS CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS SHOWN ON DRAWINGS. 2. CONTRACTOR SHALL COORDINATE WORK OF CONTRACTOR SHALL COORDINATE WORK OF ALL TRADES. 3. ALL WORK SHALL COMPLY WITH CURRENT ALL WORK SHALL COMPLY WITH CURRENT IBC. 4. CONTRACTOR TO DISPOSE OF ALL DEBRIS CONTRACTOR TO DISPOSE OF ALL DEBRIS OFF SITE.
AutoCAD SHX Text
COVER SHEET
AutoCAD SHX Text
NOTES
AutoCAD SHX Text
ELEVATIONS
AutoCAD SHX Text 1 - 6
AutoCAD SHX Text
FLOOR PLAN
AutoCAD SHX Text 2 - 6
AutoCAD SHX Text 3 - 6
AutoCAD SHX Text 4 - 6
AutoCAD SHX Text 5 - 6
AutoCAD SHX Text
ROOF PLAN
AutoCAD SHX Text 6 - 6
AutoCAD SHX Text
ELEVATIONS
AutoCAD SHX Text Sheet
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text of
AutoCAD SHX Text
DESIGN BY:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
CURTIS REINKEMEYER
AutoCAD SHX Text 9/4/2026
M
IS
SO
U
R I D
EP
A
R
TM
EN
T
O F
TR
A
N
SP
O R
TA
TI
O N
D
IV
IS
IO
N O
F G
EN
ER
A L
SE
R
V
IC
ES
FA
C
IL
IT
IE
S M
A N
A G
EM
EN
T N
O
TE
S O
ZA
R
K M
A
IN
TE
N
A N
C E
M
ET
A L
R O
O F
A N
D S
ID
IN
G
SO
U
TH
W
ES
T
D
IS
TR
IC
T
S
EL
M
O R
E R
O A
D , O
ZA
R
K , M
O
C H
R
IS
TI
A
N C
O U
N
TY
AutoCAD SHX Text BUILDING METAL (SIDING & TRIM) FULL REPLACEMENT OF BUILDING METAL SIDING AROUND THE ENTIRE STRUCTURE. CONTRACTOR TO REMOVE ALL EXISTING WALL METAL AND TRIM AND INSTALL NEW 26 GAUGE WALL METAL AND TRIM. DISCARD OFF-SITE. CONTRACTOR TO INSTALL NEW PREFINISHED ICE/SNOW GUARDS. REPLACE APPROXIMATELY 30 FEET OF DAMAGED SIDING ON THE NORTH SIDE AND 40-45 FEET ON THE SOUTH SIDE, INCLUDING DETERIORATED ANGLE IRON AND INSULATIONS NEEDED. SEE SHEET 5. CONTRACTOR TO CUT AND REPLACE 2 FEET ± OF STRUCTURAL STEEL COLUMNTHAT IS DAMAGED. SUPPLY ALL NECESSARY TEMPORARY SUPPORTS, NEW ANCHOR BOLTS AND STRUCTURAL STEEL TO MATCH EXISTING. ALL REPAIRS METHODS MUST MEET INDUSTRY AND ENGINEERING STANDARDS. STAMPED ENGINEERED REPAIRS SHALL BE SUBMITTED BY AWARDED CONTRACTOR. CONTRACTOR TO SUPPLY A BID FOR APPROXIMATELY 2440 SQUARE FEET OF ADDITIONAL WALL INSULATION FOR DISCOVERY OF WET AREAS IN WALL PANEL REMOVAL. MODOT TO BE NOTIFIED WHEN DAMAGE INSULATION IS FOUND. MODOT TO RECEIVE CREDIT BACK FOR INSULATION NOT USED. REPLACE ALL AWNING METAL TO MATCH EXISTING ARCHITECTURAL DESIGN. EXTERIOR COLOR SCHEME TO MATCH EXISTING: TAN SIDING WITH DARK BROWN (BRONZE) TRIM, DOWNSPOUTS, GUTTERS, DOORS, AWNINGS, AND FRAMING. CONTRACTOR TO VERIFY SIDING PROFILE HEIGHT TO ENSURE ALIGNMENT WITH EXISTING WINDOW ELEVATIONS. SOUTHEAST WALL METAL NEXT TO BREEZEWAY TO BE CONTINUOUS FROM ROOFLINE TO GRADE LEVEL WITH PROPER FLASHING AND SEALANT TO PREVENT WATER INTRUSION AT BREEZEWAY ROOF. BREEZEWAY METAL TO REMAIN. REPLACE LOUVERS ON THE NORTHEAST SIDE OF THE BUILDING. 3 x 3 EXHAUST FAN AND 4" x 10 VENT. VENTS TO MATCH EXISTING OR BE EQUAL TO. REMOVE AND REINSTALL REFRIGERATION LINES, ANY CONDUIT, AND OTHER EXTERIOR-MOUNTED LINES OR PANELS TO ALLOW PROPER INSTALLATION OF NEW SIDING. ALL EQUIPMENT MUST OPERATE PROPERLY AFTER REINSTALLATION. PROVIDE J- TRIM AROUND MAIN ELECTRICAL PANELS, WINDOWS, AND DOORS. REMOVE BUILDING SIGNAGE PRIOR TO WORK AND REINSTALL IN SAME LOCATION UPON COMPLETION OF SIDING INSTALLATION. PANELS DAMAGED DURING INSTALLATION OR IMPROPERLY CUT AROUND PENETRATIONS MUST BE REPLACED WITH NEW, CONTINUOUS, FULL-LENGTH SHEETS. NO HORIZONTAL OR VERTICAL SPLICES ARE ALLOWED WITHIN A SINGLE PANEL RUN. PROVIDE J-TRIM AND DRIP EDGE AT DOOR AND WINDOW HEAD TRIM.
AutoCAD SHX Text ROOF REPLACEMENT CONTRACTOR TO REMOVE ALL EXISITNG METAL ROOFING AND TRIM (DISCARD OFF-SITE) AND INSTALL NEW 26 GAUGE MECHANICALLY SEAMED ROOF AND RIDGE CAP (GALVALUME) PER MANUFACTURE INSTALLATION PROCESS. ALL STANDING SEAM PANELS SHALL BE CONTINUOUS FULL-LENGTH SHEETS FROM EAVE TO RIDGE: NO HORIZONTAL TRANSVERSE SPLICES, END LAPS, OR PATCHES ARE PERMITTED WITHIN ANY PANEL. CONTRACTOR TO REPLACE ALL ROOF INSULATION. R30. REPLACE ALL ROOF BOOTS (SIZE AS REQUIRED) AND ENSURE ALL ROOF PENETRATIONS ARE PROPERLY SEALED. REMOVE HEATER VENT PENETRATIONS FROM INFRARED AND FORCED-AIR UNITS ACROSS MULTIPLE AREAS. CONTRACTOR TO ADD A SEPARATE LINE ITEM TO BID TO ADD FALL PROTECTION TO THE ROOF SYSTEM. PERMANENT FALL PROTECTION SYSTEM SHALL MEET ALL INDUSTRY STANDARDS AND OSHA REQUIREMENTS.
AutoCAD SHX Text GUTTERS & DOWNSPOUTS CONTRACTOR TO REMOVE EXISTING GUTTERS, DOWNSPOUTS AND FASCIA. INSTALL NEW ALUMINUM 6" CONTINUOUS SEAMLESS GUTTERS AND 3" X 4" DOWNSPOUTS AND FASCIA AROUND THE ENTIRE BUILDING. DOWNSPOUTS AND GUTTERS TO BE DARK BROWN MATCHING THE BUILDING'S TRIM PACKAGE.
AutoCAD SHX Text DOORS & HARDWARE CONTRACTOR TO REPLACE (3) MAN DOORS (SIZE 36" X 7'-0" X 1-3/4" INSULATED HOLLOW (SIZE 36" X 7'-0" X 1-3/4" INSULATED HOLLOW SIZE 36" X 7'-0" X 1-3/4" INSULATED HOLLOW METAL DOOR W/ 11" X 11" X 3/4" INSUL. TEMPERED GLASS. PAINTED. REINFORCED FOR CLOSER.) ) 1-1/2 PR. BUTTS F179-4-1/2 X 4-1/2 US26D STANLEY F179-4-1/2 X 4-1/2 US26D STANLEY US26D STANLEY STANLEY 1 ENTRANCE MB1A-3-01-15-626-S1 MARSHALL BEST ENTRANCE MB1A-3-01-15-626-S1 MARSHALL BEST MB1A-3-01-15-626-S1 MARSHALL BEST MARSHALL BEST MARSHALL BEST 1 CLOSER 8616DS DORMA CLOSER 8616DS DORMA 8616DS DORMA DORMA 1 THRESHOLD 2005A 36" X AL PEMKO THRESHOLD 2005A 36" X AL PEMKO 2005A 36" X AL PEMKO 36" X AL PEMKO PEMKO 1 SWEEP 97V 36" NATIONAL GAURD SWEEP 97V 36" NATIONAL GAURD 97V 36" NATIONAL GAURD NATIONAL GAURD 1 GASKET SET 305CN PEMKO GASKET SET 305CN PEMKO 305CN PEMKO PEMKO 1 KICK PLATE 8” X DW-2” ROCKWOOD KICK PLATE 8” X DW-2” ROCKWOOD 8” X DW-2” ROCKWOOD X DW-2” ROCKWOOD ROCKWOOD EAST MAN DOOR: REPLACE FULL DOOR FRAME (16 GAUGE GALVANIZED HOLLOW METAL) WITH NEW DOOR LEAF: SET FRAME PLUMB AND SQUARE, ANCHOR PER MANUFACTURES RECOMMENDATIONS, SEAL ALL PERIMETER JOINTS AND PROVIDE CONTINUOUS WEATHER STRIPPING. WEST AND SOUTH MAN DOOR: REPLACE DOORS LEAFS AND ASSOCIATED HARDWARE: RETAIN EXISITNF FRAMES. PROVIDE NEW WEATHER STRIPPING AND THRESHOLD TO MAINTAIN EGRESS COMPLIANCE AND WEATHER TIGHTNESS. KEYING/ HARDWARE: REUSE EXISITNG BEST KEY CORE IN ALL NEW LOCKSETS. MODOT WILL RETAIN AND PROVIDE CORES FOR REINSTALLATION: CONTRACTOR SHALL PRESERVE AND RETURN ALL REMOVED CYLINDERS/ CORES TO MODOT. INSTALL NEW STAINLESS STEEL COMMERCIAL HEAVY DUTY SECURITY LATCH GUARD PLATES ON EXTERIOR MAN DOORS. OLD HARDWARE TO BE PRESERVED FOR MODOT CONTRACTOR TO COORDINATE ALL DOOR REPLACEMENTS WITH THE FACILITIES TEAM O MINIMIZE OPERATIONAL IMPACTS AND ENSURE PROPER SEQUENCING. CONTRACTOR TO REMOVE AND REPLACE METAL FRAMING AROUND ALL GARAGE DOORS; OVERHEAD DOORS AND OPERATORS WILL REMAIN UNCHANGED. ADD PVC THERMOSTOP DOORS SEALS (SEAL 5697513 P78WHT).
AutoCAD SHX Text LIGHTING CONTRACTOR TO REMOVE AND REPLACE (5) LED FIXTURES ON THE SOUTH SIDE (LITHONIA TWR1LED 1 40K MVOLT)OR EQUAL. CONTRACTOR TO PROVIDE BLOCKING, JUNCTION BOX AND ELECTRICAL WHIP AS REQUIRED FOR FUNCTIONAL SYSTEM.
AutoCAD SHX Text MECHANICAL (HEATERS & VENTING) MAIN SHOP AREA: REROUTE FORCED-AIR HEATER VENT HORIZONTALLY THROUGH THE NORTH WALL. MAIN SHOP INFRARED HEATER: REMOVE ROOF PENETRATION. FORMER TRUCK WASH AREA: REMOVE ROOF PENETRATION FROM FORCED-AIR HEATER AND REROUTE VENT HORIZONTALLY THROUGH THE NORTH WALL. WEST SHOP AREA: REMOVE ROOF PENETRATIONS NEAR TWO EXISTING INFRARED HEATERS. REMOVE OR REPLACE ALL ROOFTOP EQUIPMENT BOOTS AS REQUIRED. SIZE AS REQUIRED. ALL HVAC EQUIPMENT AND THE GENERATOR TO BE FULLY TESTED UPON PROJECT COMPLETION. GENERATOR MUST BE DISCONNECTED PRIOR TO SIDING INSTALLATION, RECONNECTED AFTER INSTALLATION, AND FULLY FUNCTION-TESTED BY THE CONTRACTOR. EXISTING GAS PIPING TO BE PAINTED YELLOW ALONG THE EXTERIOR ONLY.
AutoCAD SHX Text ELECTRICAL & LOW VOLTAGE CONTRACTOR IS RESPONSIBLE FOR ALL UTILITY LOCATES PRIOR TO WORK. DISCONNECT ELECTRICAL WIRING, ANY PANELS OR BOXES, AND CONDUIT AS REQUIRED FOR SIDING INSTALLATION. NO ELECTRICAL SPLICES OR EXTENSIONS PERMITTED- REPLACE ENTIRE CIRCUIT RUN FROM ELECTRICAL PANEL TO DEVICE, SUB PANEL, OR FIXTURE. REPLACE FUEL E-STOP BOX AND BUTTON. REPLACE WITH LIKE KIND OR EQUAL. REPLACE ALL EXTERIOR RECEPTACLES WITH SINGLE-OUTLET STYLE, PAIRED WITH NEW GFCI BREAKERS. INSTALL WEATHERPROOF, IN-USE METALLIC COVERS (HUBBELL HBL7423) AT ALL EXTERIOR RECEPTACLE LOCATIONS. COORDINATE REMOVAL OF ANTENNAS WITH FACILITIES; REINSTALL AFTER SIDING INSTALLATION. ALL BUILDING PENETRATIONS TO BE SEALED WITH PROPER INDUSTRY APPROVED SEALANT.
AutoCAD SHX Text LANDSCAPE AND GROUND RESTORATION REQUIREMENTS CONTRACTOR IS RESPONSIBLE FOR PREVENTING DAMAGE TO LANDSCAPING, GRASS AREAS, AND SOIL SURFACES DURING CONSTRUCTION ACTIVITIES. CONTRACTOR SHALL REPAIR ANY RUTS, DEPRESSIONS, OR GROUND DISTURBANCE CAUSED BY EQUIPMENT, VEHICLES, OR CONSTRUCTION OPERATIONS. REPAIRS SHALL INCLUDE REGRADING (INSURE PROPER DRAINAGE AWAY FROM BUILDING), TAMPING, AND RESTORING THE SURFACE TO ORIGINAL CONDITION.
AutoCAD SHX Text CONTRACTOR SAFETY RESPONSIBILITIES CONTRACTOR SHALL COORDINATE WITH THE SITE SUPERVISOR TO DETERMINE APPROVED LOCATIONS FOR STORING EQUIPMENT, MATERIALS, AND METAL ON SITE. THE CONTRACTOR MUST COORDINATE WITH THE SITE SUPERVISOR REGARDING OPERATIONAL HOURS. CONTRACTOR PERSONNEL SHALL WEAR APPROPRIATE PERSONAL PROTECTIVE EQUIPMENT (PPE) AT ALL TIMES WHILE ON SITE, INCLUDING HARD HATS, SAFETY VESTS, SAFETY GLASSES, GLOVES, AND ANY ADDITIONAL PPE REQUIRED BY SITE CONDITIONS. CONTRACTOR PERSONNEL AND WORK AREAS ARE SUBJECT TO UNSCHEDULED SITE SAFETY INSPECTIONS CONDUCTED BY MODOT. CONTRACTOR IS RESPONSIBLE FOR ENSURING ALL EMPLOYEES AND SUBCONTRACTORS FOLLOW ESTABLISHED SAFETY PROCEDURES AND COMPLY WITH ALL REGULATORY REQUIREMENTS. AREAS WHERE GRASS OR VEGETATION HAS BEEN DAMAGED SHALL BE RESEEDED OR REPLANTED BY THE CONTRACTOR TO ENSURE FULL RESTORATION. ALL RESTORATION WORK MUST BE COMPLETED TO MODOT STANDARDS PRIOR TO FINAL PROJECT ACCEPTANCE. CONTRACTOR SHALL MAINTAIN A CLEAN, SAFE, AND ORDERLY WORK ENVIRONMENT AT ALL TIMES WHILE ON SITE. CONTRACTOR IS RESPONSIBLE FOR SECURING ALL METAL, MATERIALS, AND EQUIPMENT STORED ON SITE TO PREVENT HAZARDS, DAMAGE, OR DISPLACEMENT DUE TO WEATHER.
AutoCAD SHX Text Sheet
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text of
AutoCAD SHX Text
DESIGN BY:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
CURTIS REINKEMEYER
WEST ELEVATION
SOUTH ELEVATION
M
IS
SO
U
R I D
EP
A
R
TM
EN
T
O F
TR
A
N
SP
O R
TA
TI
O N
D
IV
IS
IO
N O
F G
EN
ER
A L
SE
R
V
IC
ES
FA
C
IL
IT
IE
S M
A N
A G
EM
EN
T
EL
EV
A
TI
O
N S
O
ZA
R K
M A
IN
TE
N A
N C
E M
ET
A
L R
O O
F A
N D
S
ID
IN
G
SO
U
TH
W
ES
T D
IS
TR
IC
T
S
EL
M O
R E
R O
A D
, O
ZA
R K
, M O
C
H R
IS
TI
A N
C O
U N
TY
AutoCAD SHX Text B
AutoCAD SHX Text
AutoCAD SHX Text
SCALE: 1/16" = 1'-0"1/16" = 1'-0"
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
SCALE: 1/16" = 1'-0"1/16" = 1'-0"
AutoCAD SHX Text
EAVE HGT. EL. 116'-0"
AutoCAD SHX Text
FIN. FL. EL. 100'-0"
AutoCAD SHX Text 150'-0"
AutoCAD SHX Text CONTRACTOR RESPONSIBLE FOR CONTACTING, DISCONNECTING AND RECONNECTING OF ALL UTILITIES.
AutoCAD SHX Text
CONTRACTOR NOTES
AutoCAD SHX Text CONTRACTOR RESPONSIBLE EXTENDING PIPING, CONDUIT, ETC. TO ALLOW FOR A FUNCTIONAL SYSTEM AFTER NEW METAL ROOF AND WALLS ARE INSTALLED.
AutoCAD SHX Text
EAVE HGT. EL. 116'-0"
AutoCAD SHX Text
FIN. FL. EL. 100'-0"
AutoCAD SHX Text 40'-0"
AutoCAD SHX Text Sheet
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text of
AutoCAD SHX Text
DESIGN BY:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
CURTIS REINKEMEYER
EAST ELEVATION
NORTH ELEVATION
M
IS
SO
U
R I D
EP
A
R
TM
EN
T
O F
TR
A
N
SP
O R
TA
TI
O N
D
IV
IS
IO
N O
F G
EN
ER
A L
SE
R
V
IC
ES
FA
C
IL
IT
IE
S M
A N
A G
EM
EN
T
EL
EV
A
TI
O
N S
O
ZA
R K
M A
IN
TE
N A
N C
E M
ET
A
L R
O O
F A
N D
S
ID
IN
G
SO
U
TH
W
ES
T D
IS
TR
IC
T
S
EL
M O
R E
R O
A D
, O
ZA
R K
, M O
C
H R
IS
TI
A N
C O
U N
TY
AutoCAD SHX Text B
AutoCAD SHX Text
AutoCAD SHX Text
SCALE: 1/16" = 1'-0"1/16" = 1'-0"
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
SCALE: 1/16" = 1'-0"1/16" = 1'-0"
AutoCAD SHX Text
EAVE HGT. EL. 116'-0"
AutoCAD SHX Text
FIN. FL. EL. 100'-0"
AutoCAD SHX Text 150'-0"
AutoCAD SHX Text CONTRACTOR RESPONSIBLE FOR CONTACTING, DISCONNECTING AND RECONNECTING OF ALL UTILITIES.
AutoCAD SHX Text
CONTRACTOR NOTES
AutoCAD SHX Text CONTRACTOR RESPONSIBLE EXTENDING PIPING, CONDUIT, ETC. TO ALLOW FOR A FUNCTIONAL SYSTEM AFTER NEW METAL ROOF AND WALLS ARE INSTALLED.
AutoCAD SHX Text
EAVE HGT. EL. 116'-0"
AutoCAD SHX Text
FIN. FL. EL. 100'-0"
AutoCAD SHX Text 40'-0"
AutoCAD SHX Text Sheet
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text of
AutoCAD SHX Text
DESIGN BY:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
CURTIS REINKEMEYER
FLOOR PLAN
M
IS
SO
U
R I D
EP
A
R
TM
EN
T
O F
TR
A
N
SP
O R
TA
TI
O N
D
IV
IS
IO
N O
F G
EN
ER
A L
SE
R
V
IC
ES
FA
C
IL
IT
IE
S M
A N
A G
EM
EN
T
FL
O O
R P
LA
N
O
ZA
R K
M A
IN
TE
N A
N C
E M
ET
A
L R
O O
F A
N D
S
ID
IN
G
SO
U
TH
W
ES
T D
IS
TR
IC
T
S
EL
M O
R E
R O
A D
, O
ZA
R K
, M O
C
H R
IS
TI
A N
C O
U N
TY
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 14'-0"
AutoCAD SHX Text 16'-0"
AutoCAD SHX Text 14'-0"
AutoCAD SHX Text 14'-0"
AutoCAD SHX Text 22'-0"
AutoCAD SHX Text 14'-0"
AutoCAD SHX Text 4'-4"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 6'-0"
AutoCAD SHX Text 6'-8"
AutoCAD SHX Text 5'-0"
AutoCAD SHX Text 6'-0"
AutoCAD SHX Text 30'-0"
AutoCAD SHX Text 30'-0"
AutoCAD SHX Text 30'-0"
AutoCAD SHX Text 30'-0"
AutoCAD SHX Text 30'-0"
AutoCAD SHX Text AREAS OF KNOW DAMAGE INCLUDING DETERIORATED DAMAGE INCLUDING DETERIORATED ANGLE IRON AND INSULATIONS NEEDED.
AutoCAD SHX Text
AREA OF KNOW METAL COLUMN DAMAGE.
AutoCAD SHX Text AREAS OF KNOW DAMAGE INCLUDING DETERIORATED DAMAGE INCLUDING DETERIORATED ANGLE IRON AND INSULATIONS NEEDED.
AutoCAD SHX Text 30'-0"±
AutoCAD SHX Text 45'-0"±
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
SCALE: 1/16" = 1'-0"1/16" = 1'-0"
AutoCAD SHX Text Sheet
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text of
AutoCAD SHX Text
DESIGN BY:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
CURTIS REINKEMEYER
ROOF PLAN M
IS
SO
U
R I D
EP
A
R
TM
EN
T
O F
TR
A
N
SP
O R
TA
TI
O N
D
IV
IS
IO
N O
F G
EN
ER
A L
SE
R
V
IC
ES
FA
C
IL
IT
IE
S M
A N
A G
EM
EN
T R
O O
F
PL
A N
O
ZA
R K
M A
IN
TE
N A
N C
E M
ET
A
L R
O O
F A
N D
S
ID
IN
G
SO
U
TH
W
ES
T D
IS
TR
IC
T
S
EL
M O
R E
R O
A D
, O
ZA
R K
, M O
C
H R
IS
TI
A N
C O
U N
TY
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
SCALE: 1/16" = 1'-0"1/16" = 1'-0"
AutoCAD SHX Text
NEW BOOTS, SIZE AS REQUIRED. REMOVE 5 ROOF PENETRATION, SEE NOTES.
AutoCAD SHX Text Sheet
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text of
AutoCAD SHX Text
DESIGN BY:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
CURTIS REINKEMEYER
| Sheets and Views |
| Ozark Maintenance Metal Roof and Siding-Cover Sheet |
| Ozark Maintenance Metal Roof and Siding-Notes |
| Ozark Maintenance Metal Roof and Siding-Elevations |
| Ozark Maintenance Metal Roof and Siding-Elevations (2) |
| Ozark Maintenance Metal Roof and Siding-Floor Plan |
| Ozark Maintenance Metal Roof and Siding-Roof Plan |
File details come from the government source that posted it. Updated .