CLIN 0001:
MODEL 6230 SIDEVIEW
VIDEO BORESCOPE BASE-UNIT WITH TRUE PROBE
INTERCHANGEABILITY, 4-WAY ARTICULATING (6.2MM X3.0-METER)
6-INCH LCD VIEWING SCREEN, 5-AY ADJUSTABLE LED’S, ALL
ACCESSORIES AND CARRYING CASE.
AVB’s should feature detachable probes. Each AVB should include:
• (qty =2) Handheld Controlers
• (qty =3) 6.2mm dia x 3.0 m video probes.
• (qty =2) 3.9 mm dia x 1.5 m video probes.
• (qty =2) 8.4 mm dia x 6.5 m video probes.
• (qty =1) 3.9 mm dia x 3.0 m side view video probe.
• Appropriate sized carrying case(s).
• Units shall not have Bluetooth or WiFi capabilities.
Handheld controllers should have the following features:
• 5.7” Video Screen minimum.
• Ability to record pictures, audio, and video.
-Should include Microphone inputs.
-Should store in JPG (1024x768 (4:3) or 1200x720 (16:9) or MOV (960x720) formats.
-Should store on standard SD cards
• Rechargeable batteries a 4 hour battery life (minimum).
• Built in speakers.
• Magnetic Base.
• Articulating, manual joystick control.
• Gridline Overlay System.
• Digital Zoom.
-6 Levels (.5X, 1X, 1.5X, 2X, 2.5X, 3X) minimum.
CLIN 0002:
RECON MODEL 8465
PROBE ONLY (8.4MM X 6.5 METER)
4 WAY ARTICULATING WITH 5 WAY ADJUSTABLE LED’S.
Probes should have the following features:
• Should have at least 1,000,000 pixels.
• Tungsten Braid outer cover
• Field of view -(3.9 mm) > 90 degrees -(6.2 mm & 8.4 mm) > 120 degrees
• Depth of view -(3.9 mm) > 2mm – 80 mm.
-(6.2 mm & 8.4 mm) 2 mm to infinity.
• Illumination -6 Ultra White LED with variable (5 levels or more) brightness.
• Articulation -160 degree bending angle (minimum), should be able to rotate 360 degrees.
CLIN 0003:
RECON MODEL 3915
PROBE ONLY (3.9MM X 1.5 METER)
4 WAY ARTICULATING WITH 5 WAY ADJUSTABLE LED’S.
Probes should have the following features:
• Should have at least 1,000,000 pixels.
• Tungsten Braid outer cover
• Field of view -(3.9 mm) > 90 degrees -(6.2 mm & 8.4 mm) > 120 degrees
• Depth of view -(3.9 mm) > 2mm – 80 mm.
-(6.2 mm & 8.4 mm) 2 mm to infinity.
• Illumination -6 Ultra White LED with variable (5 levels or more) brightness.
• Articulation -160 degree bending angle (minimum), should be able to rotate 360 degrees.
CLIN 0004:
RECON MODEL 6230
PROBE ONLY (6.2MM X 3.0 METER)
4 WAY ARTICULATING WITH 5 WAY ADJUSTABLE LED’S.
Probes should have the following features:
• Should have at least 1,000,000 pixels.
• Tungsten Braid outer cover
• Field of view -(3.9 mm) > 90 degrees -(6.2 mm & 8.4 mm) > 120 degrees
• Depth of view -(3.9 mm) > 2mm – 80 mm.
-(6.2 mm & 8.4 mm) 2 mm to infinity.
• Illumination -6 Ultra White LED with variable (5 levels or more) brightness.
• Articulation -160 degree bending angle (minimum), should be able to rotate 360 degrees.
CLIN 0005:
MODEL 3930N SIDEVIEW.
VIDEO BORESCOPE BASE UNIT WITH TRUE PROBE
INTERCHANGEABILITY,
4-WAY ARTICULATING (3.9MM X 3.0-METER). PROBE 90-DEGREE
SIDEVIEW,
6-INCH LCD VIEWING SCREEN, 5-WAY ADJSUTABLE LED's, ALL
ACCESSORIES AND CARRYING CASE.
AVB’s should feature detachable probes. Each AVB should include:
• (qty =2) Handheld Controlers
• (qty =3) 6.2mm dia x 3.0 m video probes.
• (qty =2) 3.9 mm dia x 1.5 m video probes.
• (qty =2) 8.4 mm dia x 6.5 m video probes.
• (qty =1) 3.9 mm dia x 3.0 m side view video probe.
• Appropriate sized carrying case(s).
• Units shall not have Bluetooth or WiFi capabilities.
Handheld controllers should have the following features:
• 5.7” Video Screen minimum.
• Ability to record pictures, audio, and video.
-Should include Microphone inputs.
-Should store in JPG (1024x768 (4:3) or 1200x720 (16:9) or MOV (960x720) formats.
-Should store on standard SD cards
• Rechargeable batteries a 4 hour battery life (minimum).
• Built in speakers.
• Magnetic Base.
• Articulating, manual joystick control.
• Gridline Overlay System.
• Digital Zoom.
-6 Levels (.5X, 1X, 1.5X, 2X, 2.5X, 3X) minimum.
CLIN 0006:
RECON MODEL 6230
PROBE ONLY (6.2MM X 3.0 METER)
4 WAY ARTICULATING WITH 5 WAY ADJUSTABLE LED’S.
Probes should have the following features:
• Should have at least 1,000,000 pixels.
• Tungsten Braid outer cover
• Field of view -(3.9 mm) > 90 degrees -(6.2 mm & 8.4 mm) > 120 degrees
• Depth of view -(3.9 mm) > 2mm – 80 mm.
-(6.2 mm & 8.4 mm) 2 mm to infinity.
• Illumination -6 Ultra White LED with variable (5 levels or more) brightness.
• Articulation -160 degree bending angle (minimum), should be able to rotate 360 degrees.
CLIN 0007:
RECON MODEL 3915
PROBE ONLY (3.9MM X 1.5 METER)
4 WAY ARTICULATING WITH 5 WAY ADJUSTABLE LED’S.
Probes should have the following features:
• Should have at least 1,000,000 pixels.
• Tungsten Braid outer cover
• Field of view -(3.9 mm) > 90 degrees -(6.2 mm & 8.4 mm) > 120 degrees
• Depth of view -(3.9 mm) > 2mm – 80 mm.
-(6.2 mm & 8.4 mm) 2 mm to infinity.
• Illumination -6 Ultra White LED with variable (5 levels or more) brightness.
• Articulation -160 degree bending angle (minimum), should be able to rotate 360 degrees.
CLIN 0008:
RECON MODEL 8465
PROBE ONLY (8.4MM X 6.5 METER)
4 WAY ARTICULATING WITH 5 WAY ADJUSTABLE LED’S.
Probes should have the following features:
• Should have at least 1,000,000 pixels.
• Tungsten Braid outer cover
• Field of view -(3.9 mm) > 90 degrees -(6.2 mm & 8.4 mm) > 120 degrees
• Depth of view -(3.9 mm) > 2mm – 80 mm.
-(6.2 mm & 8.4 mm) 2 mm to infinity.
• Illumination -6 Ultra White LED with variable (5 levels or more) brightness.
• Articulation -160 degree bending angle (minimum), should be able to rotate 360 degrees.