This is a Sources Sought notice issued by the Department of Veterans Affairs Strategic Acquisition Center on behalf of the Veterans Health Administration for the Zeiss FORUM Image Digitization System: Ophthalmic product line. The VA intends to award a Requirements Contract with Firm-Fixed Price orders for nationwide supply and delivery of this ophthalmic image digitization equipment to VA medical centers and facilities throughout the United States. The anticipated contract period consists of one 12-month base period with four 12-month option periods, with continuation subject to successful performance and continued need. The NAICS code 339113 applies with a size standard of 800 employees. All offerors must be registered in SAM and certified with the appropriate NAICS code; SDVOSB/VOSB offerors must also be verified in the SBA VetCert database.
The scope includes 21 contract line items covering the Zeiss FORUM system components and software licenses, with anticipated quantities ranging from 15 to 450 units per line item for each contract period. Vendors must demonstrate that products meet six minimum technical requirements: DICOM compatibility with VA/DOD standards and integration with Vista and VA Cerner FEDEHR; HIPAA-compliant data management; high-resolution image handling with minimal latency; Single Sign On user authentication with Active Directory; customizable clinical and administrative reporting capability; and an approved interface connection for VA Cerner FEDEHR. Required responses must include company information (full name, address, DUNS/CAGE Code, SAM UIE, business size), manufacturer or distributor details with country of origin designations, technical literature demonstrating MTR compliance with page references, service plan information specifying coverage scope and provider, ability to supply uninterrupted national-scale product availability, and an authorized distributor letter certified by the OEM. This notice is issued for planning purposes only and does not constitute a commitment to award a contract.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C10X26Q0049.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1.0 DESCRIPTION
The Veterans Health Administration (VHA) Non-Expendable Equipment National Program has identified the Zeiss® FORUM Image Digitization System: Ophthalmic product line as a candidate for the Department of Veterans Affairs VA-wide (otherwise referred to as “national”) Non Expendable Equipment (NX) Requirements contract award.
The Department of Veterans Affairs’ (VA) Office of Procurement, Acquisition and Logistics (OPAL) Strategic Acquisition Center (SAC) on behalf of VHA is issuing this Sources Sought in accordance with (IAW) FAR 10.001 to determine the availability and technical capabilities of qualified sources.
The SAC in conjunction with VHA is seeking a qualified source to provide Zeiss® brand name FORUM Image Digitization System: Ophthalmic on an agency wide basis. VA intends to award a Requirements Contract with Firm-Fixed Price (FFP) orders IAW FAR 16.503, Requirements Contract to a supplier of this equipment. Vendors will be required to deliver Zeiss® FORUM Image Digitization System: Ophthalmic to VA medical centers and facilities throughout the United States.
The anticipated period of performance is for one 12-month base period with four 12-month option periods from the date of award. However, the Government's decision as to whether or not to continue with the contract, upon annual review, will be based upon successful performance during each previous year and continued need.
The associated North American Industrial Classification System (NAICS) code for this procurement is 339113 – Surgical Appliance and Supplies Manufacturing and the associated size standard is 800 employees. The FAR Provision found at 52.204-7(b)(1) requires that “All interested Offerors must be registered in SAM prior to submitting an offer or proposal.” You may access the SAM website at Home | SAM.gov. All offerors must be certified with the appropriate NAICS code on the SAM website. All SDVOSB/VOSB offerors must be verified in the Small Business Administration (SBA) database at Veteran Small Business Certification (VetCert) database at: Veteran Small Business Certification (sba.gov) at the time of proposal submission.
This notice is for planning purposes only and does not constitute a commitment on the part of the Government to award a contract, nor does the Government intend to pay for any information submitted as a result of this notice. This Sources Sought is part of a continuous process for obtaining the latest information on the commercial status of the industry with respect to their current and near-term abilities. The information provided herein is subject to change and in no way binds the Government to solicit for, or award, a competitive contract. It is emphasized that this is a notice solely for planning and informational purposes.
2.0 SCOPE
Zeiss® FORUM Image Digitization System: Ophthalmic is designed to acquire and digitize ophthalmic (e.g., fundus camera, fluorescing angiography) images for viewing, storage, and/or printing. The imaging system typically consists of a digital camera, usually in the form of a microchip (a charge-coupled device [CCD]); digital processors for image enhancement; electronic recorder storage (e.g., CD-ROM); and printers. Ophthalmic digitization systems are intended mainly to obtain images taken from fundus and fluorescing angiography cameras
The following Contract Line Items are being considered:
| Contract Line Items |
| Manufacture |
| Part Number |
| Description |
| Base Year |
| Option Year 1 |
| Option Year 2 |
| Option Year 3 |
| Option Year 4 |
| 0001 |
| Zeiss® FORUM |
| 000000-2131-312 |
| FORUM® Archive and Viewer Pkg. (v4.0) (incl: 1 Archive, 3 Viewer, 3 DICOM CZM Instr. Connection) |
| 83 |
| 83 |
| 83 |
| 83 |
| 83 |
| 0002 |
| Zeiss® FORUM |
| 000000-2078-492 |
| FORUM® Glaucoma Workplace 2.0 (includes 3x user licenses (US Combined Report) |
| 68 |
| 68 |
| 68 |
| 68 |
| 68 |
| 0003 |
| Zeiss® FORUM |
| FORUM® ENT PKG |
| FORUM® Enterprise Package (incl. VNA, LDAP/SSO, Enterprise Backup |
| 68 |
| 68 |
| 68 |
| 68 |
| 68 |
| 0004 |
| Zeiss® FORUM |
| 000000-2020-237 |
| FORUM® Glaucoma Workplace user license (v3) (Qty 1) |
| 250 |
| 250 |
| 250 |
| 250 |
| 250 |
| 0005 |
| Zeiss® FORUM |
| 306601-8530-100 |
| FORUM® Viewer license, floating (v3) |
| 450 |
| 450 |
| 450 |
| 450 |
| 450 |
| 0006 |
| Zeiss® FORUM |
| 306601-8530-100 |
| Multi-Site Access License (v3) (one license per FORUM® server) |
| 83 |
| 83 |
| 83 |
| 83 |
| 83 |
| 0007 |
| Zeiss® FORUM |
| 306601-8530-111 |
| Scheduled forwarding license (v3) (one license per FORUM® server) |
| 68 |
| 68 |
| 68 |
| 68 |
| 68 |
| 0008 |
| Zeiss® FORUM |
| 26602-1158-323 |
| FORUM® Assist Match 1.4 (v4.0) Now incl. in FORUM® Ofc & Archive |
| 68 |
| 68 |
| 68 |
| 68 |
| 68 |
| 0009 |
| Zeiss® FORUM |
| 306601-8530-130 |
| FORUM® Tablet interface license (v3) (one license per FORUM® server) |
| 83 |
| 83 |
| 83 |
| 83 |
| 83 |
| 0010 |
| Zeiss® FORUM |
| 000000-2143-476 |
| HFA - Cirrus Review Software Combined Reports site license (v3) (one license per FORUM® server) 250 per hour |
| 100 |
| 100 |
| 100 |
| 100 |
| 100 |
| 0011 |
| Zeiss® FORUM |
| 000000-2117-638 |
| Extended Video Site License (v3) (one license per FORUM® server) with Cataract Suite Marker less - Special Offer |
| 83 |
| 83 |
| 83 |
| 83 |
| 83 |
| 0012 |
| Zeiss® FORUM |
| 000000-2127-615 |
| ZEISS Retina Workplace 2.0 (US) - Includes License Pack and 3 User Licenses |
| 83 |
| 83 |
| 83 |
| 83 |
| 83 |
| 0013 |
| Zeiss® FORUM |
| 000000-2127-546 |
| ZEISS Retina Workplace User License |
| 83 |
| 83 |
| 83 |
| 83 |
| 83 |
| 0014 |
| Zeiss® FORUM |
| 306601-8530-107 |
| FORUM®-HL7 interfaces (includes EMR, HIS, HL7-ADT and HL7-ORM) (v3)(one license per FORUM® server) |
| 83 |
| 83 |
| 83 |
| 83 |
| 83 |
| 0015 |
| Zeiss® FORUM |
| 306601-8530-101 |
| FORUM® Bi-directional DICOM interface license to CZM instrument (v3) |
| 83 |
| 83 |
| 83 |
| 83 |
| 83 |
| 0016 |
| Zeiss® FORUM |
| 306601-8530-103 |
| FORUM® interface license to 3rd party DICOM instruments includes Link net 1.0 + 3rd party DICOM Instrument |
| 83 |
| 83 |
| 83 |
| 83 |
| 83 |
| 0017 |
| Zeiss® FORUM |
| 306601-8530-104 |
| FORUM® Uni-directional DICOM file import license for 3rd party instruments (v3) |
| 83 |
| 83 |
| 83 |
| 83 |
| 83 |
| 0018 |
| Zeiss® FORUM |
| LARGE SERVER |
| Large Server |
| 23 |
| 23 |
| 23 |
| 23 |
| 23 |
| 0019 |
| Zeiss® FORUM |
| MED/LRG SERVER |
| Medium-Small Server |
| 23 |
| 23 |
| 23 |
| 23 |
| 23 |
| 0020 |
| Zeiss® FORUM |
| MED/SML SERVER |
| Medium-Small Server |
| 15 |
| 15 |
| 15 |
| 15 |
| 15 |
| 0021 |
| Zeiss® FORUM |
| SMALL SERVER |
| Small Server |
| 15 |
| 15 |
| 15 |
| 15 |
| 15 |
The Department of Veterans Affairs (VA) is seeking vendors who can provide the Zeiss® FORUM Image Digitization System: Ophthalmic brand name as listed above which meet all the following minimum technical requirements (MTR):
MTR’s 1-6 apply to all CLINs 0001-0021:
| MTR # |
| MINIMUM TECHNICAL REQUIREMENT |
| METHOD OF EVALUATION |
| MTR 1 |
| Compatibility: Must integrate seamlessly with any DICOM enabled Eye Modality regardless of manufacturer. Must be fully complaint with published VA / DOD DICOM standards for storage and forwarding to Vista and VA Cerner FEDEHR. |
| Literature Review |
| MTR 2 |
| Data Management: Ability to store, retrieve, and manage patient data securely in compliance with HIPAA and VA / DOD approved DICOM standards. |
| Literature Review |
| MTR 3 |
| Image Handling: Support for high-resolution ophthalmic images with minimal latency during retrieval. |
| Literature Review |
| MTR 4 |
| User Interface: Must have Single Sign On capabilities for user authentication with Active Directory. |
| Literature Review |
| MTR 5 |
| Reporting: Capability to generate customizable reports for clinical and administrative purposes. |
| Literature Review |
| MTR 6 |
| Connectivity: Must have an already approved interface connection for VA Cerner FEDEHR |
| Literature Review |
For each product (brand name and part number), the response must include descriptive literature demonstrating the product meets or exceeds the MTRs specified above.
The Government's intent is to include all ancillary items to ensure the equipment can function as designed by the Original Equipment Manufacturer and as clinically required. Vendors are encouraged to provide any product solution or configuration so long as they meet the MTRs. Additionally, responses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number.
Responses to this Sources Sought Notice shall include the following:
1. Does vendor offer an annual service plan, Yes or No?
2. If Yes:
a. What does the plan cover?
b. Does plan cover software updates only?
c. Does the plan cover parts repair or replacement only?
d. Does the plan cover both software and parts?
3. Vendor are requested to provide documentation that shows information on their service plan.
4. Is the service provided by the OEM or a subcontractor?
5. Full name and address of company
6. DUNS number/ CAGE Code/ SAM UIE
7. Business Size
8. Manufacturer or Distributor
a. If distributor provide full name, business size and address of manufacturer.
9. Country of Origin designation for all products
10. Ability to provide uninterrupted supply of products on a national scale.
11. Technical Literature that clearly shows product(s) meet the identified minimum technical requirements and page numbers where each minimum technical requirement is met.
12. Any additional product solution or configuration that would be beneficial to the clinical functionality of the product line identified.
13. Authorized Distributor Letter Certified by OEM with a current date.
Although not required, vendors responding to this Sources Sought may also submit a Capabilities Statement.
File details come from the government source that posted it. Updated .