Old Stone Church Drawings 2024_07.pdf
PDF 1 MB Posted
- Attached to
- 2024-07 Old Stone Church Addition
- Solicitation number
- PE-77598-NONST-2024-000000008
- Issued by
- Candler County, Georgia
About this file
This document contains information about a local government contract opportunity issued by the Catoosa County Board of Commissioners in Georgia. The County is seeking qualified vendors to construct a 277 square foot addition onto the existing Old Stone Church historical building located at 41 Old Catoosa Pkwy in Ringgold, GA. Bid documents are available on the County website, and two copies of bids must be delivered to the Board of Commissioners office by 2:00 p.m. EST on Thursday, September 5, 2024. Bids will be publicly opened and read aloud, and any inquiries must be submitted in writing by 12:00 noon on Tuesday, August 27, 2024, with the County publishing responses on Friday, August 30, 2024. Catoosa County reserves the right to accept or reject any and all bids, and any bid shall remain open for acceptance for 30 days from the bid due date.
There is no information provided about pricing terms, set asides, incumbents, funding requirements and sources, or other salient commercial details. The document focuses on the procedural aspects of the solicitation process, including bid submission requirements, response deadlines, and the County's rights regarding bid acceptance.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| RFP 2024_07 Old Stone Church Addition.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CHECKER
AUTHOR:
DATE
JOB NO:
SHT TITLE:
COPYRIGHT C 2019
ROSS ANDREWS ARCHITECT, INC.
PROJECT NAME &
ADDRESS:
OWNER:
ROSS ANDREWS
ARCHITECT, INC.
7831 NASHVILLE STREET
RINGGOLD, GA 30736
706-935-6344 ross@rossandrewsarchitect.com www.rossandrewsarchitect.com
CONSULTANT:
S T
A T
U S
/7
/2
:5
:4
P
M
G001
Checker
Author
12/7/22
COVER/CODES/
SHEETS
S T
O N
E C
H U
R C
H A
D D
IT
IO
N
O
L D
C A
T O
O S
A P
A R
K W
A Y
O
L D
C O
H U
T T
A R
O A
D R
IN
G
G O
L D
G
A
CATOOSA HISTORICAL
SOCIETY
C D
12/7/22
STONE CHURCH ADDITION
ARCHITECTURAL SHEET LIST
Sheet Number Sheet Name
A001 SITE PLAN
A101 FIRST FLOOR PLAN
A121 RCP, POWER, WALL SECTION,
MISC
A201 BUILDING ELEVATIONS
CODE CHECK
APPROVALS
DRAWINGS
SITE
PERSPECTIVE
GENERAL INFORMATION SHEET LIST
Sheet Number Sheet Name
G001 COVER/CODES/ SHEETS
G101 LIFE SAFETY PLAN
CODE CHECK
DESIGN DOCUMENTATION AND INSTALLATION REQUIREMENTS
I. PROJECT IDENTIFICATION:
A. PROJECT NAME: STONE CHURCH ADDITION
B. PROJECT ADDRESS: 41 OLD CATOOSA PARKWAY
C. PROJECT DESCRIPTION (SCOPE OF WORK): ADD A LIBRARY ROOM
D. FIRE DISTRICT:
E. PROJECT CONTACT PERSON AND ARCHITECT:
ROSS ANDREWS ARCHITECT, 7831 NASHVILLE STREET,
RINGGOLD, GA 30736
PHONE/FAX: 706-935-6344. GA LICENSE #: RA005576, TENN LICENSE #: 13161,FL LICENSE #:
95694
ROSS@ROSSANDREWSARCHITECT.COM
F. ENGINEERS:
G. JURISDICTION FOR APPROVAL: CATOOSA COUNTY
H. OWNER: CATOOSA HISTORICAL SOCIETY, BILL CLARK 706-965-7438 bclark@catt.com
I. CONTRACTOR: TBD
J. DATE: 2018
II. BUILDING REGULATIONS:
A. CODES:
(GEORGIA)
2018 101 LIFE SAFETY CODE (NFPA)
2018 INTERNATIONAL BUILDING CODE (IBC)
2018 INTERNATIONAL FUEL GAS CODE
2018 INTERNATIONAL MECHANICAL CODE
2018 INTERNATIONAL PLUMBING CODE
2020 NEC NATIONAL ELECTRICAL CODE NFPA 70
2018 INTERNATIONAL FIRE CODE
2015 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) WITH 2020 GEORGIA SUPPLEMENTS AND
AMENDMENTS
2018 INTERNATIONAL RESIDENTIAL CODE
2010 ADA
(INCLUDE ALL STATE AMENDMENTS TO THE ABOVE CODES)
B. ZONE:
C. VARIANCES, APPEALS, EQUIVALENCIES, AND AUTHORITY GRANTING APPROVAL: N/A
III.OCCUPANCY GROUP(S):
A. OCCUPANCY TYPE: IBC (302)= A3 , NFPA(CH 6)=
B. OCCUPANT LOAD/FLOOR: (SEE LIFE SAFETY PLAN)
1. FIRST FLOOR: IBC (1004.1.2)= 277/100= 3 PEOPLE IN ADDITION. ADD 128 EXISTING PEOPLE , NFPA (7.3.1.2)=
3. TOTAL: 131 PEOPLE
IV. CONSTRUCTION:
A. TYPE: IBC (TABLE 601)= IV , NFPA (TABLE A.8.2.1)=
B. LIVE LOADS:
1. ROOF (SNOW): 20 PSF
2. WIND: 12.5 PSF
3. FLOOR(S): 100 PSF ASSEMBLY
5. SEISMIC PERFORMANCE: CATEGORY C, Av = .10, Aa = .10
V. BUILDING DESCRIPTION:
A. AREA: ALLOWED ACTUAL
1. 1ST FLR.: IBC (TABLE 503)= 15,000 SF 1918+277=2,195 SF
B. HEIGHT: 12'
ALLOWED IS MORE THAN ACTUAL SO OKAY
C. NUMBER OF STORIES: ONE
D. CONSTRUCTION FIRE PROTECTION: IBC (TABLE 601)
1. PARTY AND FIRE WALLS: N/A
2. INTERIOR BEARING WALLS: 0
3. INTERIOR NONBEARING PARTITIONS: 0
4. COLUMNS: 0
5. BEAMS, GIRDERS: 0
6. FLOOR/CEILING ASSEMBLY: 0
7. ROOF/CEILING ASSEMBLY: 0
8. EXTERIOR BEARING WALLS: 2
9. EXTERIOR NONBEARING WALLS: 0
10. TENENT SEPARATION: N/A
11. CORRIDORS (IBC 1018, TABLE 1018.1): N/A
12. SHAFT ENCLOSURES: N/A
13. OCCUPANCY SEPARATIONS: N/A
14. STAIR ENCLOSURES: N/A
15. ROOF COVERINGS: N/A
E. DISTANCE TO PROPERTY LINES: TABLE 602 IBC FOR FIRE RATINGS
SETBACKS ACTUAL
1. FRONT:
2. LEFT:
3. REAR: >60'
4. RIGHT: =EXISTING
F. % OPENINGS IN WALLS ("R" IF RATED OPENING) 705.8 IBC
ALLOWED ACTUAL
1. LEFT:
2. REAR: N/A
3. RIGHT: N/A
VI. FIRE SAFETY/ MEANS OF EGRESS DESIGN:
A. CONCEPT:
1. SEPARATION
A.FIRE WALLS (IBC TABLE 706.4) : N/A
B. NFPA(8.2.1) CONSTRUCTION TYPE SEPARATION FIRE BARRIERS (2 HR). N/A
2. HORIZONTAL EXITS: N/A
3. TRAVEL DISTANCE TO EXITS (IBC TABLE 1016.2): 200'
NFPA(A.7.6.1)
4. NO. OF EXITS REQUIRED (IBC 1021):1 FOR ADDITION/ 2 FOR BLDG
1-500=2, 501-1,000=3, >1,000=4
NPFA(7.4.1)=1-500=2, 501-1,000=3, >1,000=4
5. FIRE/ DRAFT STOPS: N/A
6. DEAD END ALLOWED (IBC 1018.4): 20'
NFPA (A.7.6.1)
7. SMOKE BARRIERS: N/A
9. COMMON PATH OF TRAVEL DISTANCE (IBC 1014.3 AND/OR 1025.8) :
NFPA(A.7.6.1) 75'
10. PANIC HARDWARE (IBC 1008.1.10):
VII.FIRE PROTECTION DEVICES:
A. SPRINKLERS (IBC 903): N/A
B. STANDPIPES: N/A
C. PORTABLE FIRE EXTINGUISHERS: YES (NFPA 10- PORTABLE FIRE EXTINGUISHERS) EVEN IF BUILDING
IS SPRINKLERED. MAXIMUM DISTANCE TO EXTINGUISHER IS 75' FOR CLASS “A” FIRES.
D. FIRE ALARMS (IBC 907): N/A
E. SMOKE DETECTORS: N/A
F. FIRE HYDRANT: N/A TO THIS ADDITION
1. STATIC PRESSURE (PSI):
2. RESIDUAL PRESSURE (PSI, 20 PSI MIN.):
3. FLOW (GPM, 500 GPM MIN.):
4. PARTY RESPONSIBLE FOR TAKING TEST (NAME AND ADDRESS):
5. DATE TEST TAKEN:
6. TIME TEST TAKEN (AM/PM):
7. ELEVATION OF TEST HYDRANT:
VIII.INTERIOR FINISHES (IBC TABLE 803.5):
WALL/CEILING FLOOR
A. EXITS: B DOC FF-1 “PILL TEST” (CPSC 16 CRR, PART 16300)
B. CORRIDORS: B “
C. OTHER AREAS: C “
IX. PARKING REQUIREMENTS: EXISTING
A. HC SPACES:
B. TOTAL SPACES/ SIZES:
X. LIGHTING:
A. EMERGENCY (IBC 1006): YES
B. EXIT SIGNS/ ADA (IBC 1011): N/A
XI. MECHANICAL:
A. RATED ENCLOSURE: N/A
B. SMOKE DETECTORS/ ALARMS: N/A
XII.PLUMBING:
A. #PEOPLE/ PLUMBING CODE:
B. DESCRIPTION (EXISTING, SO N/A)
1. FEMALE:
WC:
LAVS:
2. MALE:
WC:
URINAL:
LAVS:
3. DRINKING FOUNTAIN:
4. SERVICE SINK:
XIII. ENERGY
A. WALLS: R9.5 CONTINUOUS INSUL PLUS FILL CELLS WITH FOAM INSULATION.
B. ROOF: R38
C. FLOOR:
D. FENESTRATION: N/A
FIXED= U 0.38, OPERABLE= U 0.45, ENTRANCE DOORS= U 0.77
SHGC= O.40
ADDITION
R e vi si o n
N u m b e r
R e vi si o n
D e sc ri p tio n R e vi si o n
D a te
WH
U P
R
DOOR CAPACITY FACTOR:
.2"/OCCUPAN
T
36" DOOR=33/.2=165 OCC.
42" DOOR=39/.2=195 OCC.
44" DOOR= 41/.2=205 OCC.
(2) 36" DOORS=67/.2=335 OCC.
(2) 42" DOORS=79/.2=395 OCC.
(2) 44" DOORS=83/.2=415 OCC.
0' - 2 1/2"
OCCUPANT LOADS SF/ PERSON
7 NET ASSEMBLY , CONCENTRATED WITH
CHAIRS
100 GROSS BUSINESS
15 NET STAGE
15 NET ASSEMBLY , LESS CONCENTRATED
20 NET CLASS
300 GROSS STORAGE
1 2
A
B
3' - 6"
12' - 8"
MOBILE DISPLAY ONE SIDE AND
BOOKS THE OTHER. THIS WAY VISITORS
CAN SEE MORE HISTORY WITHOUT
ACCESSING THE LIBRARY
GLASS WALL
APPROX 235 SF APPROX 235 SF
PREVIOUS LIBRARY
WAS 277 SF.
VIEWING AREA
AND AVOIDS
A LONG HALL FEEL.
ANGLED WALL OPENS TO LARGER
SANCTUARY WITH WELCOMING FEEL.
SANCTUARY FEEL IS
MAINTINAED BECAUSE
IT STILL CAN BE USED
FOR GROUPS AND YET
ONE CAN SEE THE FULL SPACE
SIZE THROUGH THE GLASS WALLS.
DELIGHTFUL TABLE
AT WINDOW FOR
RESEARCH.
COMPUTER AND AWARENESS
OF WHO IS IN THE SPACE, BOTH
VISITOR AND USER.
APPROX 64 LIN FT 8' STOREFRONT
AT 3-4" OC VERT MULLIONS.
1 2
A
B
A201
A201 3 A2012
COMMON TRAVEL:
35'-6", BUT 75' ALLOWED.
TOTAL EGRESS FOR
67 PEOPLE, SO
36" DOOR IS OKAY.
277 SF/100= 3 PEOPLE
1918 SF
EXISTING BLDG
1918/15=128 PEOPLE
IN MUSEUM TYPE SETTING.
P E
O P
L E
E G
R E
S S
CHECKER
AUTHOR:
DATE
JOB NO:
SHT TITLE:
COPYRIGHT C 2019
ROSS ANDREWS ARCHITECT, INC.
PROJECT NAME &
ADDRESS:
OWNER:
ROSS ANDREWS
ARCHITECT, INC.
7831 NASHVILLE STREET
RINGGOLD, GA 30736
706-935-6344 ross@rossandrewsarchitect.com www.rossandrewsarchitect.com
CONSULTANT:
S T
A T
U S
/7
/2
:5
:3
P
M
G101
RSA
RSA
12/7/22
LIFE SAFETY PLAN
S T
O N
E C
H U
R C
H A
D D
IT
IO
N
O
L D
C A
T O
O S
A P
A R
K W
A Y
O
L D
C O
H U
T T
A R
O A
D R
IN
G
G O
L D
CATOOSA HISTORICAL
SOCIETY
C D
12/7/22
1/2" = 1'-0"
DOOR OCCUPANT CAPACITY
1/8" = 1'-0"
OCCUPANT LOADS SF/ PERSON
R e vi si o n
N u m b e r
R e vi si o n
D e sc ri p tio n R e vi si o n
D a
FUTURE OPTION. NOT A PART OF THIS CURRENT PROJECT
EXISTING MANHOLES W/ 4" SANITARY SEWER @ .66 SLOPE
176' - 0"
SS
10' - 0"
ABANDONED ROAD
EXISTING STONE CHURCH
ADDITION
EXISTING MANHOLE AND
8" SANITARY SEWER
EXISTING MANHOLE
AND 8" SEWER FROM
PLAY GROUND
10' -
6.8'
GRADE TO
INVERT
14.5'
GRADE TO
INVERT
ADD A MANHOLE
PLUMBING NOTE:
THE EXISTING 4" SANITARY SEWER NEEDS TO BE RELOCATED AT LEAST 10'
FROM THE NEW ADDITION. TWO OPTIONS ARE SHOWN IN ORDER FOR THE
PLUMBER TO RECOMMEND THE LEAST EXPENSIVE SOLUTION.
OPTION 1: MOVE THE EXISTING MANHOLE UP THE PAGE AND ADD (2) 5" DONUTS
TO THE HEIGHT.
OPTION 2: ADD A MANHOLE
THE DIFFERENCE MAY COME DOWN TO THE DEPTH TO DIG.
EXISTING 4" SANITARY SEWER
TO REMAIN
8" SANITARY SEWER RELOCATION
AS PER CITY OF RINGGOLD SANITARY SEWER
CONSTRUCTION SPECIFICATIONS. USE SDR 26 PIPE
AT 0.4% MIN. GRADE.
CHECKER
AUTHOR:
DATE
JOB NO:
SHT TITLE:
COPYRIGHT C 2019
ROSS ANDREWS ARCHITECT, INC.
PROJECT NAME &
ADDRESS:
OWNER:
ROSS ANDREWS
ARCHITECT, INC.
7831 NASHVILLE STREET
RINGGOLD, GA 30736
706-935-6344 ross@rossandrewsarchitect.com www.rossandrewsarchitect.com
CONSULTANT:
S T
A T
U S
/7
/2
:5
:4
P
M
A001
RSA
RSA
12/7/22
SITE PLAN
S T
O N
E C
H U
R C
H A
D D
IT
IO
N
O
L D
C A
T O
O S
A P
A R
K W
A Y
O
L D
C O
H U
T T
A R
O A
D R
IN
G
G O
L D
CATOOSA HISTORICAL
SOCIETY
C D
12/7/22
1" = 10'-0"
Site Plan
R e vi si o n
N u m b e r
R e vi si o n
D e sc ri p tio n R e vi si o n
D a te
S A
N
IT
A R
Y S
E W
E R
/1
/1
REF.
1 2
23' - 0"
A
B
6' - 0"6' - 0"
A101
A101
A201
A201 3
A2012
E Q
E Q
10' - 7 1/8" 10' - 7 1/8"
/8
NOTES:
1. (21 ) BOOK SHELVES: 36"X7' EACH
WITH 5 SHELVES
14.5" VERTICALLY ON CENTER, OFFERING
5 PLUS TOP, OR 6 SHELVES. THIS
ALLOWS FOR 21X6X3= 378 LINEAR FEET
OF SHELVES. (NIC) PURCHASED AND
INSTALLED BY OWNER/ RETAILER.
2. TYP FILING CABINET (NIC).
PURCHASED AND INSTALLED BY OWNER.
3. REMOVE EXISTING WINDOW AND
PATCH TO MATCH. (2 HR RATING).
4. RELOCATE EXISTING 4" SEWER TO BE
OUTSIDE OF NEW ADDITION. THIS HAS
BEEN OKAYED BY CITY OF RINGGOLD
ENGINEER AS BEIGN POSSIBLE. VISIT
THE SITE AND SEE WHAT NEEDS TO BE
DONE. PERHAPS A NEW MANHOLE WILL
BE NEEDED. INSTALL CHANGE PER CODE.
5. 3'X7' METAL EXTERIOR DOOR WITH
LEVER HANDLE, STOREROOM FUNCTION
LOCK, HOLD OPEN CLOSER, HOLLOW
METAL FRAME. 90 MIN LABEL FIRE DOOR.
6. EXISTING REFRIGERATOR TO REMAIN.
7. (2) 6' TABLES BY OWNER.
8. SEE WALL SECTION ON A121
277 SF
LIBRARY
ADDITION
DASHED FUTURE
LIBRARY SHELVES
Level 1 0' - 0"
Exist Roof 13' - 9 5/8"
12 3
A101
NEW WALL
9' - 2"
A121
THRU WALL
A/C
EMERGENCY LIGHT/ BATTERY
Level 1 0' - 0"
Exist Roof 13' - 9 5/8"
A B
A101
NEW WALL
9' - 2"
2X8 AT 16"
2X6 @ 16" INSTALL A 2 HR WALL TO SEPARATE THE
EXISTING BUILDING FROM THE NEW.
USE 2 HR FIRE SAFING UP IN THE RAFTERS
AS SHOWN. WALL= (2) LAYERS 5/8" GYP
EACH SIDE OF 2X4'S AT 16" OC.
1 2
A
B
A201
A201 3 A2012
SEALANT AND BACKER ROD
REQUIRED AT WALL AND ROOF
JUNCTURE WITH THE HISTORIC
STONE BUILDING.
NEW ROOFING AND GUTTERS AND DOWNSPOUTS
TO MATCH EXISTING.
CONTINUE NEW SHINGLES OVER EXISTING
"TRIANGLE" AREAS AS NEW ROOF FLUSHES
WITH THE EXISTING HIP ROOF.
CHECKER
AUTHOR:
DATE
JOB NO:
SHT TITLE:
COPYRIGHT C 2019
ROSS ANDREWS ARCHITECT, INC.
PROJECT NAME &
ADDRESS:
OWNER:
ROSS ANDREWS
ARCHITECT, INC.
7831 NASHVILLE STREET
RINGGOLD, GA 30736
706-935-6344 ross@rossandrewsarchitect.com www.rossandrewsarchitect.com
CONSULTANT:
S T
A T
U S
/7
/2
:0
:1
P
M
A101
RSA
RSA
12/7/22
FIRST FLOOR PLAN
S T
O N
E C
H U
R C
H A
D D
IT
IO
N
O
L D
C A
T O
O S
A P
A R
K W
A Y
O
L D
C O
H U
T T
A R
O A
D R
IN
G
G O
L D
CATOOSA HISTORICAL
SOCIETY
C D
12/7/22
1/4" = 1'-0"
Level 1
1/4" = 1'-0"
TRANSVERSE BUILIDNG SECTION
1/4" = 1'-0"
LONGITUDINAL BUILDING SECTION
1/8" = 1'-0"
Roof
R e vi si o n
N u m b e r
R e vi si o n
D e sc ri p tio n R e vi si o n
D
REF.
REF.
1 2
A
B
A201
A201 3 A2012
A A
AA
E
TYP. 2X4 SURFACE MOUNTED ACRYLIC LENSE
LED FIXTURES EQUAL TO 4 LAMP FLOURESCENT
LUMENS.
EMERGENCY LIGHT LED FIXTURE:
BATTERY BACK UP 90 MIN.
Level 1 0' - 0"
NEW WALL
9' - 2"
0' - 0 3/4"
0' - 7 5/8"
0' - 2 1/2"
MATCH EXISTING SOFFIT:
FASCIA, SOFFIT, CONT.
VENT,
ESTIMATED
ELEVATION:
R 38 INSUL W/
KRAFT VB TOWARDS
ROOM. PROVIDE BAFFLES
AT WALL AS REQ'D.
2' - 0"
0' - 5 1/2"
TYP 3/4" STUCCO ON 8" CMU W/
2" RIGID INSUL (MIN R9.5), "C" SHAPPED FURRING
AT 16" OC, 1/2" GYP BD PAINTED. EXTERIOR
FINISH AND CONSTRUCTION TO MATCH EXISTING.
4" COVE RUBBER BASE INSIDE. FOAM INSULATION IN
ALL VOID CELLS OF CMU.
FOOTING DEPTH TO MATCH EXISTING:
INCLUDE FRENCH DRAIN AROUND EXTERIOR
AS SHOWN- EXIT TO GRADE.
NOTE: ANY WALL BELOW GRADE TO HAVE
WATERPROOFING AND DRAIN MAT AS PER
EXISTING TO RELIEVE WALL FROM HYDROSTATIC
PRESSURE.
2X6 RAFTERS W/ 5/8" PLYWOOD SHEATHING
AND 30 LB FELT AND SHINGLES TO MATCH
EXISTING.
2X8 CEILING JOISTS
W/ 5/8" GYP BD PAINTED.
8" CMU WALL: USE REINFORCED PILASTERS
AT 4' OC AND CORNER BARS IN EACH OF 3 CELLS.
EACH CELL IN PILASTER TO HAVE 1#4 VERTICAL
FROM FOOTING AND 6" INTO BOND BEAM. INSTALL
HORIZONTAL REINF AT 16" OC CONT.
/8
CONT. BOND BEAM: (2) #5'S WITH
CORNER BARS LAPPED 25".
PRESSURE TREATED 2X8 ANCHORED
W/ 1/2" BOLTS AT 32" OC. HURICANE
CLIPS ON RAFTERS.
(2) #5 REBARS CONT. WITH
25" LAPS AND USE CORNER
BARS. PROVIDE 3" CLEARANCE
TO ALL DIRT.
FRENCH DRAIN TO GRADE, WITH
SOIL FABRIC AND GRAVEL SURROUND
R15 RIGID INSULATION AROUND
PERIMETER.
4" 3,000 PSI CONCRETE ON
10 ML VB ON 4" GRAVEL ON
COMPACTED FILL TO 95%
PROCTOR. FINISH FLOOR
TO MATCH EXISTING.
NOTE: AT EXISTING BUILDING JUNCTURE WITH THE
HISTORIC STONE STRUCTURE INSTALL BACKER ROD
AND SEALANT TO STOP THE RAIN LEAKS. THIS IS A
CONDITION AT THE WALL AND ROOF JUNCTURE WITH
THE STONE BUILDING. THE ORIGINAL ASPHALT IMPREGNATED
CONTINOUS FILL HAS FAILED.
STONE WALL BEYOND.
1/2" GYP BD ON 2" METAL "Z" FURRING
WITH FULL THICK RIGID INSUL. R10
/4
/4
/4
/4
/4
/4
3' - 0"
THIS FIXED SHELF SHOULD HANDLE ANY SIZE
BOOK,
EVEN INTO THE FUTURE IF ONE NEEDS TO BE
ADDED
TO A SHELF THAT HAS SMALLER BOOKS INITIALLY.
OPEN TOP FOR MORE BOOKS
1 2
A
B
A101
A101
A201
A201 3
A2012
23' - 0"
6' - 0"
E Q
E Q
10' - 7 1/8" 10' - 7 1/8"
/8
NOTES:
1. RELOCATED METERED SERVICE.
2. EXISTING POWER PANEL
3. RELOCATE A/C DISCONNECT AND
COMPRESSOR.
4. NEW THROUGH THE WALL AIR
CONDITIONER:
7,400 BTU, 240 VOLT.
+60"
+60"
TYP INTERNET CABLE
BY OWNER, OR USE
WIFI.
CHECKER
AUTHOR:
DATE
JOB NO:
SHT TITLE:
COPYRIGHT C 2019
ROSS ANDREWS ARCHITECT, INC.
PROJECT NAME &
ADDRESS:
OWNER:
ROSS ANDREWS
ARCHITECT, INC.
7831 NASHVILLE STREET
RINGGOLD, GA 30736
706-935-6344 ross@rossandrewsarchitect.com www.rossandrewsarchitect.com
CONSULTANT:
S T
A T
U S
/7
/2
:0
:3
P
M
A121
RSA
RSA
12/7/22
RCP, POWER, WALL
SECTION, MISC
S T
O N
E C
H U
R C
H A
D D
IT
IO
N
O
L D
C A
T O
O S
A P
A R
K W
A Y
O
L D
C O
H U
T T
A R
O A
D R
IN
G
G O
L D
CATOOSA HISTORICAL
SOCIETY
C D
12/7/22
1/8" = 1'-0"
Level 1
3/4" = 1'-0"
TYP WALL SECTION
1" = 1'-0"
TYP SHELF ELEV
1/4" = 1'-0"
Level 1 POWER PLAN
R e vi si o n
N u m b e r
R e vi si o n
D e sc ri p tio n R e vi si o n
D
Level 1 0' - 0"
Exist Roof 13' - 9 5/8"
T.O. Footing -5' - 0"B.O. Footing -6' - 0"
12 3
A101
NEW WALL
9' - 2"
DOWNSPOUTS RELOCATED
AS SHOWN. PIPE TO EXISTING
UNDERGROUND, OR CONSULT
ARCHITECT IF GRADE SPLASH
BLOCK
IF GRADE MUST GO ABOVE
FINISHED FLOOR PROVIDE
WATERPROOFING TO
MATCH
TYP STUCCO
Level 1 0' - 0"
Exist Roof 13' - 9 5/8"
T.O. Footing -5' - 0"B.O. Footing -6' - 0"
AB
A101
NEW WALL
9' - 2"
EXISTING EARTH
AGAINST
PROVIDE MATCHING WATER PROOFING
TO EXISTING WHEREVER EARTH COMES
ABOVE THE FINISH FLOOR LEVEL..
IT IS PREFERRED TO NOT HAVE EARTH
ABOVE THE FLOOR AS SHOWN, BUT
SITE CONDITIONS WILL GOVERN.
CONCRETE PAD FOR
RELOCATED
Level 1 0' - 0"
Exist Roof 13' - 9 5/8"
T.O. Footing -5' - 0"B.O. Footing -6' - 0"
A B
A101
NEW WALL
9' - 2"
CHECKER
AUTHOR:
DATE
JOB NO:
SHT TITLE:
COPYRIGHT C 2019
ROSS ANDREWS ARCHITECT, INC.
PROJECT NAME &
ADDRESS:
OWNER:
ROSS ANDREWS
ARCHITECT, INC.
7831 NASHVILLE STREET
RINGGOLD, GA 30736
706-935-6344 ross@rossandrewsarchitect.com www.rossandrewsarchitect.com
CONSULTANT:
S T
A T
U S
/7
/2
:5
:0
P
M
A201
RSA
RSA
12/7/22
BUILDING
ELEVATIONS
S T
O N
E C
H U
R C
H A
D D
IT
IO
N
O
L D
C A
T O
O S
A P
A R
K W
A Y
O
L D
C O
H U
T T
A R
O A
D R
IN
G
G O
L D
CATOOSA HISTORICAL
SOCIETY
C D
12/7/22
1/4" = 1'-0"
NORTH
1/4" = 1'-0"
EAST
1/4" = 1'-0"
WEST
SHINGLES TO
MATCH
R e vi si o n
N u m b e r
R e vi si o n
D e sc ri p tio n R e vi si o n
D
File details come from the government source that posted it. Updated .