Statement of Work/Specifications RFP No. NTIA0000-19-00121

1.0 BACKGROUND

Radio propagation measurement, analysis, and modeling are core functions of the Institute for Telecommunication Sciences (ITS). The primary functions of several key programs at ITS, including the Propagation Modeling, Clutter Measurements, and mm-wave programs, for example, are to measure, analyze, and model the effects of the radio propagation channel on the transmission and reception of radio signals. Radio propagation measurements form the basis of this work. To carry out these measurements, ITS relies on custom-built measurement systems. ITS requires mm-wave transmitter components such as frequency multipliers, amplifiers, filters, RF- power sensors, coaxial cables, and antennas to be able to construct and test these custom-built measurement systems to support laboratory experiments and field measurements related to emerging fifth generation (5G) mobile wireless technology.

2.0 OBJECTIVE

The objective of this procurement is to acquire a wideband, continuous wave (CW), 40-watt, traveling wave tube (TWT) power amplifier that operates at millimeter-wave (mm-wave) frequencies (26.5 – 40 GHz) for radio propagation measurements using ITS custom-built measurement systems.

3.0 FUNCTIONAL SPECIFICATIONS

Functional Specifications for mm-wave CW 40-Watt TWT Power Amplifier

General
Must be operable outdoors, field deployable, and transportable
Frequency Range
26.5 – 40.0 GHz Minimum
RF Output Power (Saturated) at TWT Output
40 W Minimum CW
Gain
70 dB Minimum
Gain Flatness
±3 dB Maximum preferred, ±6 dB Maximum acceptable
RF Input VSWR
2.5:1 Maximum
Maximum RF Load VSWR without damage
At least 2.0:1
Source/Load Protection
Minimum Solution: Amplifier shuts down if Maximum RF Load VSWR (see line above) is exceeded.

Preferred Solution: Amplifier operates without damage or oscillation for any source or load impedance.

RF Input Power for Saturated Output
Include label showing required RF Input Power vs. Frequency
Maximum RF Input Power without damage
At least -10 dBm
Harmonic Response
-8 dBc Maximum
Non- Harmonic Spurious Responses
-50 dBc or better
Operating Voltage
110 VAC ±10%, Single Phase, 47-63 Hz
Power Consumption
Steady State: 900 VA maximum
Inrush Current
15 A Maximum
RF Output Connector
WR-28 Waveguide, Must mate with UG599/U Square Flange
RF Input Connector
2.4 mm Female preferred, 2.92 mm Female acceptable
RF Output Sample Port
40 dB or 50 dB Coupling, 2.4 mm Female preferred, 2.92mm Female acceptable
Connector Locations
Waveguide connector placement to permit unobstructed direct connection to customer supplied horn antenna and provide E-field orientation as shown in diagram below
Mating Connectors
Mating connectors and caps provided for all non-RF connectors
Operating Ambient Temperature Range
5°C to +40°C Minimum at 5000 ft. above sea level
Relative Humidity
0 to 95% non-condensing
Shock
Meets functional shock test described in Sections 3.8.5.1 & 4.5.5.4.1 of MIL-PRF-28800F or equivalent
Vibration
Meets random vibration test described in Sections 3.8.4.1 & 4.5.5.3.1 of MIL-PRF-28800F for Class 3 equipment or equivalent
Operating Altitude
0 to 10,000 ft. above sea level
Remote Monitor and Control
Ethernet
Cooling
Self-Contained Forced Air
Warranty
Two (2) Years Minimum
Design Style
Either Integrated Design (Single Enclosure housing both power supply and RF unit) or Split Design (Power supply and RF unit separate) if reduced size/weight of RF unit (compared to an Integrated Design) can be achieved (see size and weight specifications below)

Design Style Dependent Specifications

Design Style Options ->
Integrated Design
Split Design
Weatherproofing (Enclosure & Connectors)
IP54 Minimum, NEMA 4 Preferred
Power Supply: NEMA 1

RF Unit: IP54 Minimum, NEMA 4 Preferred

Enclosure Mounting
Capability to securely mount bottom of enclosure to customer-supplied plate that is mounted on a telescoping mast (see diagram below)
Power Supply: Standard 19” EIA Rack Mountable

RF Unit: Capability to securely mount bottom of enclosure to customer-supplied plate that is mounted on a telescoping mast (see diagram below)

Size (Goal: Minimize)

10” H x 12” W x 24” L Maximum
Power Supply: 10” H x 19” W x 28 “ L Maximum

RF Unit: 10” H x 12” W x 24” L Maximum

Weight (Goal: Minimize)

50 lbs. Maximum
Power Supply: 50 lbs. Maximum

RF Unit: 35 lbs. Maximum

Power Supply to RF Unit Cables & Connectors (Only needed for split designs)

N/A
One ruggedized 12 ft and one ruggedized 40 ft power supply cable† are required along with two extra bulkhead connectors and four bulkhead connector caps.

†The 12 ft. cable must connect from the power supply to a bulkhead connector. The 40 ft. cable must connect from that bulkhead connector to the RF unit.

DIAGRAM OF CUSTOMER-SUPPLIED PLATE SHOWING MOUNTING

RF Output WR-28 Showing E-Field Orientation

Power Amplifier E 30’ Telescoping Mast Drawing not to scale RF Input, RF Output Sample, Control/Monitor, and Power Connectors Customer-Supplied Plate ≈ 24” ≈ 10” ≈ 12”

4.0 PERIOD OF PERFORMANCE:

7 months from Date of Award

5.0 DELIVERABLE SCHEDULE:

Within 7 months ARO (after receipt of order) FOB Destination

6.0 TECHNICAL POINTS OF CONTACT:

CONTRACTING OFFICER’S REPRESENTATIVE:

Kenneth Calahan #303-497-3792 KCalahan@ntia.gov

PRIMARY TECHNICAL POINT OF CONTACT:

Jeff Wepman 303 497-3165 JWepman@ntia.gov

ALTERNATE TECHNICAL POINT OF CONTACT:

John Ewan #303 497-3059 JEwan@ntia.gov

7.0 INVOICING:

Please submit invoices to: invoice@nist.gov with a copy to the COR, TPOC’s and Contracting Officer.

image1.wmf

File details come from the government source that posted it.