NOAA Standard Specification MOC-573-2 Overhaul Repair of Hydraulic Cylinders.pdf

PDF 20 KB Posted

Attached to
Reference Documents for DORFP 1305M224R0042 – NOAA Ship Thomas Jefferson FY25 Repairs Services
Solicitation number
1305M224R0042
Issued by

About this file

This document is the National Oceanic and Atmospheric Administration (NOAA) Standard Specification MOC-573-2 for the overhaul and/or repair of hydraulic cylinders. It outlines the minimum requirements for this work, including tagging out the system, disconnecting and capping the hydraulic lines, removing and transporting the cylinder to a repair facility, disassembling and cleaning the cylinder, preparing and preserving the external painted surfaces, reassembling the cylinder using new seals and gaskets, reinstalling the cylinder, and testing the system. The specification also requires a condition report detailing the inspection results and any additional parts or labor required to restore the cylinder to the manufacturer's specifications. This specification is referenced in the NOAA Ship Thomas Jefferson FY25 Repairs Services solicitation, which is a delivery order competition for an existing multiple award IDIQ contract for NOAA dockside support services.

View the file

Other files

File Type Posted
625-6634893J_Doors Hatches Windows and Airports.pdf PDF
Refrigeration Valves and Parts.pdf PDF
561-6634811 Steering System Hydraulic Sys.pdf PDF
TJ_85_TJ-085-002_RevJ_BOOKLET OF GENERAL PLANS.pdf PDF
TJ-432-003_Rev -0_Dial Telephone System LAN System Modifications.pdf PDF
Hose McCann 2213-100-451_PA_GA Layout.pdf PDF
521-6634792E Fire Main Sys Arr Dets.pdf PDF
TJ-583-023B Davit Hydraulic Modifications_103556824.pdf PDF
521-6634791D Fire Main System Dia.pdf PDF
refer system drawing with cond.pdf PDF
Liferaft Certificates.pdf PDF
Compressor_Start_Up_Report.pdf PDF
TJ-985-6634639O Fire Control Plan_130928347.pdf PDF
Amdt_0001-TJ-985-6634639O Fire Control Plan_130928347.pdf PDF
Amdt_0001-Liferaft Certificates.pdf PDF
Amdt_0001-TJ-583-023B Davit Hydraulic Modifications_103556824.pdf PDF
Amdt_0001-561-6634811 Steering System Hydraulic Sys.pdf PDF
Comdial Wiring Panels_J-boxes.pdf PDF
243-6634745A Shaft Brake Arrngmnt.pdf PDF
320-6634679_Cableway Arrangement and Details.pdf PDF
163-6634821_Seachest Details.pdf PDF
501-6634837B Reach Rod ARR_Details.pdf PDF
512-6634841_ HVAC Diagram.pdf PDF
TJ-551-004 Whistle Comp Air System Arrangement_Details.pdf PDF
TJ FY25 Fire Sys Inventory_Portable Fire Extinguishers.pdf PDF
NOAA Standard Specification AMC-635-2 Thermal Insulation for Compartments.pdf PDF
NOAA Thomas Jefferson Ships Registry TTS.pdf PDF
Fire and Detection Alarm System_As Built_12122023.pdf PDF
TJ-170-6634883-F.pdf PDF
101-6634865 Structural Module 6.pdf PDF
TJ-180-001_Generic winch foundation.pdf PDF
TJ-635-6634624_Insulation Layout and Details.pdf PDF
151-6634890 Bulwark and Misc Details.pdf PDF
TJ-233-03 EMD Engine_Maintenance Instruction_1722 Rev I.pdf PDF
TJ-514-003_-_Refrigerant System and Condensate Piping Modifications.pdf PDF
TJ-583-03A Davit_Hydrographic Survey Launch (HSL).pdf PDF
501-6634831_Piping Module No 3.pdf PDF
Zenitel Bill of Materials_Item 3.11.pdf PDF
NOAA Thomas Jeffersonr2_XLS_Zenitel.xls XLS spreadsheet
426-6634694 Gyro Compass Sys.pdf PDF
633-67635_Installation Drawing ICCP Equipment.pdf PDF
514-3275003-6 REV A AC PIPING INSTL 2ND DK_BLW.pdf PDF
801-6634641_Table of Offsets.pdf PDF
512-6634850F HVAC ARRNGMNT ENGRM_124644191.pdf PDF
Electro-Motive MI 1722_Maintenance Instruction.pdf PDF
Hose McCann 6080-PNL-437-DS_R0_Panel Wiring.pdf PDF
801-6634640_Hull Lines.pdf PDF
NOAA Standard Specification 997-1B Drydocking-Routine_Drydock-Work.pdf PDF
TJ-331-002 LIGHTING MODS INCID TO SEWAGE TANK AERATION SYSTEM_124586215.pdf PDF
EMI 17300_Feedeback Linkage Diagram.pdf PDF
Show 40 more

Latest 50 of 188 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

MOC-573-2

September 2000

National Oceanic and Atmospheric Administration Marine Operation Center

Standard Specification MOC-573-2

OVERHAUL/REPAIR OF HYDRAULIC CYLINDERS

1. SCOPE: This specification provides the minimum requirements for the overhaul and/or repair of hydraulic cylinders.

2. REFERENCES

None

3. REQUIREMENTS

3.1 Tag out system controllers and actuators to preclude

inadvertent operation and secure the movable member to prevent movement while cylinder is removed.

3.1.1 Disconnect and cap hydraulic lines from the cylinder.

Ensure containment is provided to prevent spillage of oil.

Hydraulic lines and inlet/outlet ports shall be capped or plugged with threaded fittings to prevent leakage or contamination of the system.

3.1.2 Remove the cylinder from the ship and transport to

repair facility.

3.2 Perform the following work on the removed cylinder:

3.2.1 Completely disassemble the cylinder and clean all

parts.

3.2.2 Prepare and preserve the external painted surfaces in

accordance with the identified painting specification or as original.

3.2.3 Reassemble the cylinder under clean conditions using

new "O" rings, seals, gaskets, packing, and piston rings.

Materials used shall meet or exceed original manufacturers specifications. During reassembly lubricate the above with a product equal to Hilton's Hyper-Lube, that is compatible with the system fluid.

3.2.4 Provide and install new nuts, washers, bolts, studs and inlet and outlet fittings.

3.3 Reinstall the cylinder in its original location.

MOC-573-2

September 2000

3.4 Top off hydraulic reservoir to full mark and purge all air from the system taking care to contain any fluid bled off.

3.5 Remove tag outs.

4. QUALITY ASSURANCE

4.1 After disassembly, inspect all components for trueness of bore and rod, wear, damage, corrosion or pitting. Provide a Condition Report detailing the inspection results, contractor's corrective action recommendations, and list of additional parts, material and labor not covered by this specification, required to restore the cylinder to the manufacturers specifications.

4.2 After reassembly, bench test the assembly at system working pressure to prove smoothness of operation and tightness of sealing surfaces.

4.3 Cycle the cylinder through a minimum of four evolutions to demonstrate operation and tightness of all disturbed fittings and connections. Upon satisfactory demonstration of operation and tightness apply "Denso tape" to all connections.

END OF SPECIFICATION