NOAA Standard Specification MOC-300-3 General Requirements for Electrical_Electronic Items.pdf
PDF 22 KB Posted
- Attached to
- MO FY27 Thomas Jefferson Drydock REFERENCES and ATTACHMENTS Federal contract opportunity
- Solicitation number
- 1305M226Q0100REF
About this file
This is a standard specification document for electrical and electronic work performed on NOAA vessels. Issued in September 2000 by the National Oceanic and Atmospheric Administration's Marine Operations Center, MOC-300-3 establishes general requirements and quality standards for all electrical and electronic system installations and repairs on ships.
The specification mandates that contractors perform all work in accordance with IEEE STD 45-1988 (Recommended Practice for Electric Installations on Shipboard) and U.S. Coast Guard 46 CFR 110-113 regulations, utilizing best marine and shipbuilding practices. All materials must be marine-grade with quality matching References 2.1 and 2.2, suitable for marine service, and identical in shape, color, and finish to original materials when new. New cabling must be low-smoke type and appropriately sized for intended use. All electrical cabling extensions must route through junction boxes and be installed behind existing paneling in cableways, securely banded to hangers. Cabling must be identified with embossed metal tags at each end, with nonconductive labels used within junction boxes using a marking system consistent with existing ship standards. Electronic racks must be securely fastened to structural members to prevent movement. Any machinery, piping, cabling, insulation, paneling, or other items removed, disturbed, or damaged during work must be replaced, renewed, or repaired to match original specifications. Disturbed painted or varnished surfaces must be cleaned and refinished with original materials. All manufacturer warranties must be assigned to the Government in writing, and three copies of technical manuals, prints, and drawings, along with spare parts and surplus materials, must be delivered to the Contracting Officer's Technical Representative (COTR). Quality assurance requires all disturbed items and installed devices be demonstrated fully operational upon work completion.
View the file
Other files for this federal contract opportunity
Show all 50
MO FY27 Thomas Jefferson Drydock REFERENCES and ATTACHMENTS has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MOC-300-3
September 2000
NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION (NOAA)
MARINE OPERATIONS CENTER
STANDARD SPECIFICATION MOC-300-3
GENERAL REQUIREMENTS FOR ELECTRICAL/ELECTRONIC ITEMS
1. SCOPE. This specification provides general requirements for work performed on electrical and electronic systems.
2. REFERENCES.
2.1 IEEE STD 45-1988, Recommended Practice for Electric
Installations on Shipboard (series)
2.2 U. S. Coast Guard 46 CFR 110 through 113, “Subchapter J - Electrical Engineering”
3. REQUIREMENTS.
3.1 The contractor shall accomplish all work in these
specifications in accordance with the requirements of References
2.1 and 2.2, and using the best marine and shipbuilding practices.
3.2 The quality of all materials provided by the contractor
shall be in accordance with References 2.1 and 2.2, suitable for marine service, and have the same shape, color, and finish as the existing or damaged materials when they were new.
3.3 All new cabling shall be low smoke and sized for the cable’s intended use.
3.4 All machinery, piping, cabling, ducts, insulation, paint
work, deck tile, or any other article removed, disturbed, or damaged in the process of accomplishing the work required by these specifications shall be replaced, renewed, or repaired.
All paneling removed shall be replaced, including any required alterations. Paneling damaged by the contractor shall be renewed equal to the original when new. All flanges and joints broken or loosened shall be properly remade using new gaskets of the proper size and material.
3.5 All electronic racks installed shall be securely fastened to overhead and deck structural or steel members to prevent movement.
3.6 Any disturbed painted or varnished surfaces shall be
cleaned, painted, and/or varnished with original type and color of paint or varnish.
MOC-300-3
September 2000
3.7 Any extension of electrical cabling shall be through a
junction box. Any removal of electrical cabling shall be to the nearest junction box.
3.8 All electrical junction boxes, receptacles, hangers, and
miscellaneous electrical fittings shall be in accordance with References 2.1 and 2.2.
3.9 All electrical cabling installed by the contractor shall be run behind paneling in existing cableways and shall be securely banded to the hangers. If existing cableways are not available, new cableways shall be established.
3.10 All electrical cabling installed by the contractor shall be identified at each end with embossed metal tags. Where cables are marked within a junction or terminal box, nonconductive labels shall be used. The contractor shall number cabling with a marking system similar to that used on the ship.
3.11 All manufacturer's or supplier's standard warranties on
equipment installed on the ship shall be assigned in writing by the contractor to the Government.
3.12 Three copies all manufacturer's technical manuals, prints, and drawings shall be delivered to the COTR. Spare parts and surplus installation materials shall be delivered to the COTR.
4. QUALITY ASSURANCE.
4.1 All items disturbed and all devices used, repaired, altered, furnished, or installed by the contractor shall be demonstrated to be fully operational upon completion of work.
END OF SPECIFICATION