Specification for Optical Fiber Cables

Common specs to all cables:

All cables shall have a 2 mm diameter polyvinylidene fluoride (PVDF) outer jacket.

All polyvinylidene fluoride shall be pre-baked before installation onto the cables.

All fiber numerical apertures shall be in the range of 0.09 to 0.14.

Item 1 Fiber: Singlemode for 355 nm, 125 um clad 2mm OD PVDF Jacket 3 Meters Long, FC/APC to FC/APC FC/APC Connector Label = Lab FC/APC Connector Label = Lab Cable Label (Middle) = xx um, yy NA, [where xx is the core diameter and where yy is the NA] Qty=2

Item 2 Fiber: PM SM for 355 nm, 125 um clad 2mm OD PVDF Jacket 3 Meters Long, FC/APC to FC/APC FC/APC Connector Label = Lab FC/APC Connector Label = Lab Cable Label (Middle) = xx um, yy NA, [where xx is the core diameter and where yy is the NA] Qty=2

Item 3 Fiber: Singlemode for 355 nm, 125 um clad 2mm OD PVDF Jacket 3 Meters Long, FC/APC to FC/PC FC/APC Connector Label = Lab FC/PC Connector Label = Lab Cable Label (Middle) = xx um, yy NA, [where xx is the core diameter and where yy is the NA] Qty=2

Item 4 Fiber: PM SM for 355 nm, 125 um clad 2mm OD PVDF Jacket 3 Meters Long, FC/APC to FC/PC FC/APC Connector Label = Lab FC/PC Connector Label = Lab Cable Label (Middle) = xx um, yy NA, [where xx is the core diameter and where yy is the NA] Qty=2

Item 5 Fiber: Singlemode for 405 nm, 125 um clad 2mm OD PVDF Jacket 3 Meters Long, FC/APC to FC/APC FC/APC Connector Label = Lab FC/APC Connector Label = Lab Cable Label (Middle) = xx um, yy NA, [where xx is the core diameter and where yy is the NA]

Item 6

Fiber: PM SM for 405 nm, 125 um clad 2mm OD PVDF Jacket 3 Meters Long, FC/APC to FC/APC FC/APC Connector Label = Lab FC/APC Connector Label = Lab Cable Label (Middle) = xx um, yy NA, [where xx is the core diameter and where yy is the NA] Qty=2

Item 7 Fiber: Singlemode for 405 nm, 125 um clad 2mm OD PVDF Jacket 3 Meters Long, FC/APC to FC/PC FC/APC Connector Label = Lab FC/PC Connector Label = Lab Cable Label (Middle) = xx um, yy NA, [where xx is the core diameter and where yy is the NA] Qty=2

Item 8 Fiber: PM SM for 405 nm, 125 um clad 2mm OD PVDF Jacket 3 Meters Long, FC/APC to FC/PC FC/APC Connector Label = Lab FC/PC Connector Label = Lab Cable Label (Middle) = xx um, yy NA, [where xx is the core diameter and where yy is the NA] Qty=2

Item 9 Fiber: Singlemode for 532 nm 125 um clad 2mm OD PVDF Jacket 3 Meters Long, FC/APC to FC/APC FC/APC Connector Label = Lab FC/APC Connector Label = Lab Cable Label (Middle) = xx um, yy NA, [where xx is the core diameter and where yy is the NA] Qty=2

Item 10 Fiber: PM SM for 532 nm, 125 um clad 2mm OD PVDF Jacket 3 Meters Long, FC/APC to FC/APC FC/APC Connector Label = Lab FC/APC Connector Label = Lab Cable Label (Middle) = xx um, yy NA, [where xx is the core diameter and where yy is the NA] Qty=2

Item 11 Fiber: Singlemode for 532 nm, 125 um clad 2mm OD PVDF Jacket 3 Meters Long, FC/APC to FC/PC FC/APC Connector Label = Lab FC/PC Connector Label = Lab Cable Label (Middle) = xx um, yy NA, [where xx is the core diameter and where yy is the NA] Qty=2

Item 12 Fiber: PM SM for 532 nm, 125 um clad

3 Meters Long, FC/APC to FC/PC FC/APC Connector Label = Lab FC/PC Connector Label = Lab

Item 13 Fiber: Singlemode for 633 nm, 125 um clad 2mm OD PVDF Jacket 3 Meters Long, FC/APC to FC/APC FC/APC Connector Label = Lab FC/APC Connector Label = Lab Cable Label (Middle) = xx um, yy NA, [where xx is the core diameter and where yy is the NA]

Qty=2

Item 14 Fiber: PM SM for 633 nm, 125 um clad 2mm OD PVDF Jacket 3 Meters Long, FC/APC to FC/APC FC/APC Connector Label = Lab FC/APC Connector Label = Lab Cable Label (Middle) = xx um, yy NA, [where xx is the core diameter and where yy is the NA] Qty=2

Item 15 Fiber: Singlemode for 633 nm, 125 um clad 2mm OD PVDF Jacket 3 Meters Long, FC/APC to FC/PC FC/APC Connector Label = Lab FC/PC Connector Label = Lab Cable Label (Middle) = xx um, yy NA, [where xx is the core diameter and where yy is the NA]

Qty=2

Item 16 Fiber: PM SM for 633 nm, 125 um clad 2mm OD PVDF Jacket 3 Meters Long, FC/APC to FC/PC FC/APC Connector Label = Lab FC/PC Connector Label = Lab

Item 17 Fiber: Singlemode for 1064 nm, 125 um clad 2mm OD PVDF Jacket 3 Meters Long, FC/APC to FC/APC FC/APC Connector Label = Lab FC/APC Connector Label = Lab Cable Label (Middle) = xx um, yy NA, [where xx is the core diameter and where yy is the NA]

Item 18

Fiber: PM SM for 1064 nm, 125 um clad

3 Meters Long, FC/APC to FC/APC FC/APC Connector Label = Lab FC/APC Connector Label = Lab Cable Label (Middle) = xx um, yy NA, [where xx is the core diameter and where yy is the NA] Qty=2

Item 19 Fiber: Singlemode for 1064 nm, 125 um clad 2mm OD PVDF Jacket 3 Meters Long, FC/APC to FC/PC FC/APC Connector Label = Lab FC/PC Connector Label = Lab Cable Label (Middle) = xx um, yy NA, [where xx is the core diameter and where yy is the NA] Qty=2

Item 20 Fiber: PM SM for 1064 nm, 125 um clad 2mm OD PVDF Jacket 3 Meters Long, FC/APC to FC/PC FC/APC Connector Label = Lab FC/PC Connector Label = Lab