NET ZERO IDIQ SS Atch 3 Questionnaire 3 JAN 2024.xlsx
XLSX spreadsheet 100 KB Posted
- Solicitation number
- FA8903-AENETZERO
About this file
This sources sought notice requests feedback from industry on architect-engineer services for vertical design with a focus on new construction and renovation projects supporting Executive Order 14057's goals of net zero emissions. Required services include planning, design, and construction phase support. Responses are sought by February 2nd, 2024 for an estimated indefinite delivery indefinite quantity multiple award task order contract exceeding $2 billion to be awarded in the second half of fiscal year 2024. Services shall include Title I design, Title II construction phase support, and other related services for the Air Force, Army Corps of Engineers, and Army Installation Management Command. Experience is requested in areas like passive design, energy and water efficiency, electrification, sustainability certifications, and commissioning. Responses should demonstrate in-house capabilities and experience meeting the executive order's goals using the provided templates.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| NETZERO IDIQ SS Atch 1 Questionnaire 3 JAN 2024.xlsx | XLSX spreadsheet | |
| NET ZERO Atch 2 Proj Exp Outline 3 JAN 2024.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Tab 1 - Labor Capacity Vertical Design Firm Capacity Questionnaire
PLEASE COMPLETE TAB 1
Attachment 3 Your Firm Name:
| Key Personnel Availability at Your Firm |
| A. Position Description |
| B. Minimum Qualifications |
| C. Average number of full-time employed staff in your firm per year, averaged over the last 3 years (Do not double count staff in multiple positions; a single employee may only be indicated once. Do not count administrative, drafting, program management, or other staff not otherwise meeing the minimum qualifications and roles identified below for each category. |
| D. Where Column C is zero, Identify firm name(s) for firm(s) used to provide these services and and status(es) as Small Business (SB) or Large Business (LB) |
| E. Where Column C is zero, Identify number of years active experience working with the firm identified in Column D. |
| A. | B. | C. | D. | E. |
| Position | Minimum Qualifications | # On Staff | Employer (Firm) Name & Size Status | If a Teaming Partner, |
Years Working with Prime (The "Prime" is the Firm submitting this response)
| Project Manager* | Professional Engineering (PE) registration or Registered Architect (RA) and 8 years experience as a project manager |
| Architect Sr.* | RA and 10 years experience |
| Architect Mid.* | RA and 5 years experience |
| Architect Jr.* | RA and 2 years experience |
| Interior Designer Sr.* | Registered Interior Designer (RID) and 10 years experience |
| Interior Designer Mid.* | RID and 5 years experience |
| Interior Designer Jr.* | RID and 2 years experience |
| Structural Engineer Sr.* | PE and 10 years experience |
| Structural Engineer Mid.* | PE and 5 years experience |
| Structural Engineer Jr.* | PE and 2 years experience |
| Civil Engineer Sr.* | PE and 10 years experience |
| Civil Engineer Mid.* | PE and 5 years experience |
| Civil Engineer Jr.* | PE and 2 years experience |
| Mechanical Engineer Sr.* | PE and 10 years experience |
| Mechanical Engineer Mid.* | PE and 5 years experience |
| Mechanical Engineer Jr.* | PE and 2 years experience |
| Electrical Engineer Sr.* | PE and 10 years experience |
| Electrical Engineer Mid.* | PE and 5 years experience |
| Electrical Engineer Jr.* | PE and 2 years experience |
| Fire Protection Engineer Sr.* | PE and 10 years experience |
| Fire Protection Engineer Mid.* | PE and 5 years experience |
| Fire Protection Engineer Jr.* | PE and 2 years experience |
| Historical Preservation Architect Sr.* | RA and 10 years experience |
| Professional Land Surveyor | Professional Land Surveyor (PLS) and 5 years experience |
| Construction Cost Estimator Sr. | 10 years experience in cost estimating |
| Construction Cost Estimator Mid. | 5 years experience in cost estimating |
| Construction Cost Estimator Jr. | 2 years experience in cost estimating |
| Construction Scheduler Sr. | 10 years experience in scheduling |
| Construction Scheduler Mid. | 5 years experience in scheduling |
| Construction Scheduler Jr. | 2 years experience in scheduling |
| *All positions marked with asterisk must possess a bachelor's degree from an accredited school in an engineering or architecture related field. |
image1.jpeg image2.png
File details come from the government source that posted it. Updated .