About this file

This Requirements/Specifications document is for a NIST federal contract opportunity (NB688000-25-02425) seeking software development for the ARTIQ experimental control system used in quantum computing research. The primary requirement is for software, firmware, and gateware to enable two key technical capabilities: 1) RTIO (Real-Time Input/Output) event batching for Zynq-based core devices, which will increase event throughput by collecting and transmitting RTIO events in batches, and 2) integrating the ndscan package into ARTIQ without requiring source code patching. The contract specifies that the developed functionality must be integrated into the main ARTIQ GitHub repository and included in the next ARTIQ release, with usability through standard installation channels. The contract is for a single item with a delivery timeline of 12 months from award, and includes planned government acceptance testing over 7 business days.

View the file

Other files for this federal contract opportunity

Other files attached to ARTIQ Zynq Batching and ND Scan, newest first.
File Type Posted
NB688000-25-02425 RFQ ARTIQ Batching.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Requirements / Specifications: ARTIQ Zynq Batching and NDSCAN 1 Version 1.0 (2019) Double-click on for further assistance.

Use this document to detail specifications/requirements for an item and/or ancillary services.

TITLE: ARTIQ Zynq Batching and NDSCAN Requesting Lab/Division/Group: Physical Measurements Lab/Time and Frequency Division/Ion Storage Group

NB688000-25-02425

General Statement of Need The Ion Storage Group at NIST performs a variety of quantum computing, quantum simulation, and optical clock experiments using trapped ions. These experiments are very complex and require advanced real-time classical control. The ARTIQ experimental control system, initially developed for the Ion Storage Group, is used to operate our experiments. For the next generation of quantum information and clock experiments, we require the ability to increase the throughput of RTIO events from Zynq-based core devices in ARTIQ through batching. We also require modifications to ARTIQ to enable the use of the ndscan ARTIQ extension package without patching of ARTIQ. Detailed specifications for Ion Storage Group ARTIQ Zynq event batching and ndscan compatibility requisition. Terminology is as defined in the linked GitHub repositories listed below and their associated code and documentation.

Items and/or Ancillary Services

Item 1: Software, firmware, and gateware to enable RTIO event batching on Zynq-based core devices and the use of ndscan with unpatched ARTIQ.

Quantity: 1 Specifications:

1. Must implement the capability of RTIO event batching for all Zynq-based core devices for ARTIQ (Kasli SoC and ZC706). The event batching means collecting a buffer of RTIO events from the kernel and transmitting them as a batch from the hard processor to the RTIO engine in the FPGA fabric.

2. The batching must result in an increased average sustained RTIO event throughput rate from the hard processor to the RTIO engine in the FPGA fabric relative to that achievable in ARTIQ 8.0.

3. Must develop a new context manager (such as “with batch”) to be added to ARTIQ-Python for the user to enable RTIO event batching as described above in relevant kernel sections.

4. All RTIO events within a “with batch” context will be transmitted from hard processor to the RTIO engine in the FPGA fabric as a batch, upon closing of the “with batch” context, or through an explicit method that calls for the transmission of all the currently enqueued batched events without leaving the “with batch” context.

5. All of the above functionalities must be integrated into the main ARTIQ repository at https://github.com/m-labs/artiq, must be included in the next ARTIQ release after their satisfactory completion and testing, and must be usable for ARTIQ installations made through any standard ARTIQ installation channel (not requiring ARTIQ to be built from source).

SPECIFICATIONS FOR DNSCAN INTEGRATION:

1. Must implement all necessary modifications to ARTIQ to enable the use of the ndscan package at https://github.com/OxfordIonTrapGroup/ndscan without patching ARTIQ.

2. Implementation must work for NAC-3 ARTIQ compiler.

3. All of the above functionalities must be integrated into the main ARTIQ repository at https://github.com/m-labs/artiq, must be included in the next ARTIQ release after their satisfactory

Requirements / Specifications: ARTIQ Zynq Batching and NDSCAN 2 completion and testing, and must be usable for ARTIQ installations made through any standard ARTIQ installation channel (not requiring ARTIQ to be built from source).

Separately Priced Options and Services:

Item 2: [List minimum specifications.

Quantity: [Enter quantity here.] Specifications: [Enter quantity here.]

[List any other item(s) or service requirements here using the same format above.]

Service Requirements / Item Specifications Section Requirements/Specifications Planning Considerations ☒ N/A

☐ List any visits required to allow potential vendors to see site specific constraints.

[Explain requirement here]

☐ US citizen required on-site (foreign nationals require preregistration 30 days prior) ☐ Vendor rep on-site more than three days ☐ Other considerations: [List other considerations to ensure an accurate quote]

Shipping & Delivery ☐ N/A

Standard shipping Shipping criteria:

☐ Partial delivery acceptable ☐ Direct delivery to building required

[Explain need for requirement here] Building has: ☐ Loading dock

☐ Containerization preference: [Choose container] Other requirements: [List any other requirements here]

Delivery date criteria:

☐ Delivery of goods, installation, and training shall be completed no later than:

12 Months from ARO ☐ Deliver no earlier than: [Insert date here] ☐ Other: [List other shipping, delivery, or specil requirements]

Electronic Media ☐ N/A

[Enter electronic media requirements by item here.] ☒ Software ☐ Electronic manuals ☐ License Key ☐ Other: [List any other Electronic Media requirements here] [Enter email address for software delivery here]

Installation ☒ N/A

[Enter installation requirements by item here.] ☐ Vendor technician on site ☐ Rigging ☐ Uncrating / Unpackaging ☐ Removal of packaging material ☐ Equipment set up

Requirements / Specifications: ARTIQ Zynq Batching and NDSCAN 3

☐ Start-up services ☐ Turn key installation ☐ Other [Enter details here.] Note: When installation is required, TPOC or COR shall be the coordination point.

Facility / Utility Considerations ☒ N/A

No utility or facility requirements.

☐ OFPM Work Order Number(s)

[List any Work Order Number(s) here] ☐ Power available

Voltage: [Enter voltage here] (V) Max Current: [Enter max current draw here] (A) Phase: [Choose phase] Frequency: [Typically 60Hz] (Hz) NEMA Plug Type: [Enter plug type here] (i.e.: NEMA L5-20P) Environment: [Choose environment] Other power consideration: [List any other power considerations here]

☐ Utility connections: [List relevant available utilities, pressure(s), and flowrate(s)] ☐ Other considerations: [List other considerations to ensure an accurate quote]

Warranty ☐ N/A

Base Manufacturer Warranty is acceptable [If you require an Extended Manufacturer Warranty, describe the warranty requirements per item here.] What is included?

☐ Labor ☐ Parts ☐ Travel ☐ Cost and liability for returns ☐ Other: [Enter other requirements here] ☐ Warranty length: [Enter warranty length here] Period Length:[Ex. month, 6 month, year etc.]

Training ☒ N/A

No training requirements ☐ On-site ☐ Off-site location: [Enter location(s) here] ☐ Number of trainees: [Enter number of trainees here] Scope of training:

☐ Operations ☐ Maintenance ☐ Troubleshooting ☐ Safety ☐ Other: [Enter other scope requirements here]

☐ Training materials to be provided: [Describe requirement here] ☐ Other: [Enter other training requirements here] Note: When training is required, TPOC or COR shall be the coordination point.

Inspection and Acceptance

[Enter inspection requirements per item here] ☒ Planned government acceptance testing (7 business days)

Requirements / Specifications: ARTIQ Zynq Batching and NDSCAN 4

☐ N/A ☐ Gov’t acceptance expected to take longer than 7 business days: [Duration] ☐ Inspection and acceptance plan: [Explain here] ☐ Other: [Enter other requirements here]

Maintenance ☒ N/A none Period Length: [Ex. month, 6 month, year etc.] What is included?

☐ Labor ☐ Spare parts ☐ Consumables ☐ Travel ☐ Cost and liability for returns ☐ Software updates ☐ Manuals ☐ Service plan length: [Enter service plan length here]

☐ Other: [Enter other requirements here] ☐ Requirements: [Enter requirements here] (i.e.: onsite within 72 hours, etc.)

☐ Option Period 1 ☐ Option Period 2 ☐ Option Period 3 ☐ Option Period 4

Government Furnished Material / Equipment ☒ N/A none ☐ Samples for testing ☐ Government equipment which will leave gov't site (TPOC must coordinate with division property custodian)

Serial Number: [Enter Serial Number here] Description: [Enter description here] NIST property number: [Enter NIST property number here]

☐ Other: [Enter other details here] Travel ☒ N/A none ☐ Explain: [Explain here] ☐ Other: [Enter other requirements here] Vendor: To the maximum extent possible, include as part of appropriate sections above (maintenance, repair, etc.). Otherwise, it will be a separate line item, reimbursable per the Federal Travel Regulation.

Provide suggestions to improve this form by clicking here.

https://oaam.nist.gov/OAAMAcquisitions/FormFeedback/default.aspx

Use this document to detail specifications/requirements for an item and/or ancillary services.
TITLE: ARTIQ Zynq Batching and NDSCAN
Requesting Lab/Division/Group: Physical Measurements Lab/Time and Frequency Division/Ion Storage Group NB688000-25-02425
General Statement of Need
Provide suggestions to improve this form by clicking here.

File details come from the government source that posted it. Updated .