PWS_002_23_Mayport_Bldg_1554 Cameras_JT_EDITS.docx
DOCX document 19 KB Posted
- Attached to
- Camera Replacement & Camera Installation
- Solicitation number
- N6883624Q015201
About this file
This document is a Performance Work Statement (PWS) for a proposed camera installation project at NAVSTA Mayport in Florida. The key requirements are:
The contractor must replace 6 existing cameras, install approximately 30 new 5MP IR cameras, 1 camera monitor, 2 PoE 24-port switches, and 1 DISA-approved firewall. The contractor must also create and configure camera objects within the Lenel OnGuard software to detect, surveil, and deter against unwanted intrusion, insider threats, and safety concerns. All network-connected devices must be configured in compliance with applicable Security Technical Implementation Guides (STIGs), with the contractor providing documentation of STIG compliance.
The work must be completed at NAVSUP Fleet Logistics Center Detachment Mayport. The contractor is considered the subject matter expert and may request changes to the PWS recommendations. The installation will not be considered complete until all errors are resolved. The contractor must be a Lenel Value Added Reseller.
The related federal contract opportunity is Solicitation Number N6883624Q015201 issued by the Department of the Navy's Naval Supply Systems Command for this camera replacement and installation project.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| N6945016D5632 - B1554 Warehouse Modification Project (2017).pdf | ||
| 1554_1_sqft_diagram.pdf | ||
| Combined_Synopsis_Solicitation_N6883624Q0152.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PERFORMANCE WORK STATEMENT (PWS) FOR PROPOSED CAMERA INSTALL AT NAVSTA MAYPORT, FL
PWS NUMBER:
PWS 002-23 (NAVSTA MAYPORT)
COMMAND NAME:
NAVSUP FLEET LOGISTICS CENTER JACKSONVILLE (FLCJ)
LOCATION WHERE WORK WILL BE PERFORMED:
NAVSUP FLEET LOGISTICS CENTER
DETACHMENT MAYPORT
1 MASSEY AVENUE
MAYPORT, FL 32228
PROJECT COORDINATOR POINT OF CONTACT:
MR. J. T. LANGONE
WORK: 904-542-2416
INFORMATION TECHNOLOGY (IT) POINT OF CONTACT:
MR. JOHN POTTS
WORK: 904-542-1144
POINT OF CONTACT AT LOCATION (FOR ACCESS):
MS. SYLVIA GONZALEZ
WORK: 904-804-1531
SCOPE:
NAVSUP FLCJ REQUIRES THE REPLACEMENT OF SIX (6) EXISTING CAMERAS, THE INSTALLATION OF APPROXIMATELY THIRTY (30) 5MP IR CAMERAS, ONE (1) CAMERA MONITOR, TWO (2) POE 24 PORT SWITCHES AND ONE (1) SYSTEM COMPATIBLE FIREWALL FROM THE DISA AUTHORIZED PRODUCTS LIST. CREATE AND CONFIGURE CAMERA OBJECTS WITHIN LENEL ONGUARD SOFTWARE IN ORDER TO DETECT, SURVEIL, AND DETER AGAINST UNWANTED INTRUSION, INSIDER THREATS, AND SAFETY CONCERNS. EACH NETWORK CONNECTED DEVICE MUST BE CONFIGURED IN COMPLIANCE WITH APPLICABLE SECURITY TECHNICAL IMPLEMENTATION GUIDES (STIGS). THE CONTRACTOR WILL PROVIDE DOCUMENTATION OF STIG COMPLIANCE IN THE FORM OF THE APPROPRIATE COMPLETED STIG CHECKLIST(S).
WORK TO BE COMPLETE:
1. UPGRADE SIX (6) EXISTING CAMERAS TO DIGITAL EQUIVALENTS. PROCURE, INSTALL, AND MAKE FUNCTIONAL APPROXIMATELY THIRTY (30) CAMERAS WITH EITHER WIDE ANGLE COVERAGE OR PAN/TILT/ZOOM (PTZ) SURVEILLANCE CAPABILITY, MOUNTED ON THE WAREHOUSE WALLS, POSTS, OR SUPPORTING STRUCTURES WITHIN BLDG 1554 (SEE ATTACHED MAP). PROVIDE MAXIMUM SURVEILLANCE CAPABILITIES OF IDENTIFIED NAVSUP FLCJ ASSETS. VIDEO OVERLAY FUNCTION OF THE CAMERA WILL BE DISABLED TO ENSURE NO CONFLICT WITH SERVER TIME DISPLAY WHEN PULLING RECORDED VIDEO. ADD AUDIBLE ALARM TO EXISTING WAREHOUSE DOOR (SEE ATTACHED MAP).
2. THE SOURCE FOR CAMERA POWER WILL BE POE.
3. PROGRAMMING OF THE SWITCHES AND FIREWALL WILL BE ACCOMPLISHED BY THE CONTRACTOR WITHOUT THE USE OF A GOVERNMENT COMPUTER. THE GOVERNMENT WILL PROVIDE IP ADDRESS INFORMATION FOR THAT PURPOSE. ALL UNNECESSARY SWITCH AND FIREWALL SERVICES WILL BE DISABLED.
4. CONFIGURATION OF THE CAMERAS IN ONGUARD WILL BE ACCOMPLISHED BY A PROVIDED LENEL CERTIFIED TECHNICIAN USING A GOVERNMENT COMPUTER UNDER THE DIRECT SUPERVISION OF A GOVERNMENT EMPLOYEE.
5. THE CONTRACTOR WILL PERFORM A COMPREHENSIVE OPERABILITY TEST OF THE VIDEO SYSTEM TO INCLUDE DISPLAYING LIVE AND RECORDED VIDEO.
6. IF PTZ CAMERAS ARE INSTALLED, THE CAMERAS WILL BE OPERATED BY A UNIVERSAL KEYBOARD CONTROLLER W/ MONITOR OR DIGITAL TOUCHSCREEN, COLLOCATED WITH THE NVR. CONTROLLER TO BE PROVIDED AND INSTALLED BY CONTRACTOR. A COMPUTER CANNOT BE PART OF THE CONTROLLER SOLUTION.
7. ENSURE ALL WORK LOCATIONS ARE CLEAN OF ANY DEBRIS. ENSURE ANY DAMAGE TO PAINT, DRYWALL, EXTERIOR SURFACES, ETC IS REPAIRED UPON COMPLETION OF WORK. NO CHANGE TO PHYSICAL BUILDING INFRASTRUCTURE IS AUTHORIZED. EXTERIOR MOUNTED CONDUIT MUST MATCH CUSTOMER PROVIDED PAINT SCHEMES.
EQUIPMENT TO BE INSTALLED:
1. APPROXIMATELY THIRTY (30) 5MP IR CAMERAS (OR AN AMOUNT ACCEPTABLE TO SURVEIL REQUIRED ASSETS.
2. ONE (1) CAMERA MONITOR
3. TWO (2) 24 PORT POE SWITCHES
4. ONE (1) DISA APPROVED FIRE WALL
ADDITIONAL INFORMATION/INSTRUCTIONS:
1. NO CONTRACTOR ELECTRONIC DEVICES OR COMPUTERS MAY BE CONNECTED TO THE GOVERNMENT NETWORK AT ANY TIME.
2. CAMERA AND VIDEO CABLE INSTALLATION WILL BE PERFORMED IN ACCORDANCE WITH APPLICABLE FEDERAL, STATE, AND LOCAL INSTALLATION STANDARDS.
3. CAMERAS MUST BE FULLY COMPATIBLE WITH LENEL ONGUARD VERSIONS 8.0 +.
4. THE INSTALLATION WILL NOT BE CONSIDERED COMPLETE UNTIL ALL ABNORMAL INDICATIONS & ERROR MESSAGES DIRECTLY RELATED TO THE VIDEO INSTALLATION HAVE BEEN RESOLVED.
5. CAMERA FRAME RATE CAPABILITY AND RESOLUTION SHOULD BE COMMENSURATE WITH INDUSTRY STANDARDS. CAMERA CONFIGURATION MUST SUPPORT VIDEO RETENTION FOR A MINIMUM OF 90 DAYS.
6. ESTIMATE SHALL BE ITEMIZED BY LABOR (TYPE), EQUIPMENT, AND QUANTITY TO ALLOW FOR ADJUSTMENTS BASED ON ACTUAL EQUIPMENT NEEDED AND ACTUAL COSTS INCURRED DURING PERFORMANCE.
7. THE INSTALLATION METHOD, TYPE OF MATERIALS, AND EQUIPMENT CONFIGURATION REQUIREMENTS PROVIDED IN THIS PWS ARE THE RECOMMENDATIONS OF THE CUSTOMER BASED ON THEIR KNOWLEDGE OF THE SYSTEM. THE CONTRACTOR IS CONSIDERED THE SUBJECT MATTER EXPERT. IF ANY CUSTOMER RECOMMENDATIONS CAN BE IMPROVED UPON, MODIFIED TO BETTER FIT THE REQUIREMENTS OF THE SCOPE, OR ARE INCORRECT IN THE OPINION OF THE CONTRACTOR IT IS INCUMBENT UPON THE CONTRACTOR TO REQUEST AND/OR SUGGEST CHANGES TO THIS PWS IN ORDER TO MORE ACCURATELY REFLECT THE FINAL PRODUCT/CONFIGURATION
8. ENCLOSURE (1) PROVIDES PROPOSED AREA TO BE COVERED.
9. ENCLOSURE (2) IS A LIST OF REQUIRED SYSTEM AND EQUIPMENT COMPATIBILITIES (“CAMERAS” AND IP VIDEO SOLUTION SECTIONS).
10. VENDOR SHOULD BE A LENEL VALUE ADDED RESELLER (VAR).
File details come from the government source that posted it. Updated .